LABORATORY TESTS ON MASONRY VAULTS STRENGTHENED AT THE EXTRADOS

Similar documents
BURIED VAULTS WITH DIFFERENT TYPES OF EXTRADOS FINISHES EXPERIMENTAL TESTS

EXPERIMENTAL AND NUMERICAL SIMULATIONS OF COLLAPSE OF MASONRY ARCHES

ANALYTICAL AND EXPERIMENTAL BEHAVIOR OF UNSTRENGTHENED MASONRY ARCHES

RESEARCH ON COMPOSITE STRENGTHENING OF MASONRY ARCHES

INNOVATIVE COMPOSITE MATERIALS FOR STRENGTHENING MASONRY ARCHES

Optimisation of FRP Strengthening Systems for Masonry Arch Bridges

Glass fibre reinforced textile composites strengthening solutions for masonry arches

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.5, pp ,

FRP Anchorage Systems for Infill Masonry Structures


Analytical study of a 2-span reinforced concrete beam strengthened with fibre reinforced polymer

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

Experimental analysis and modelling of masonry vaults strengthened by FRP

LOAD TESTS ON 2-SPAN REINFORCED CONCRETE BEAMS STRENGTHENED WITH FIBRE REINFORCED POLYMER

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

Experimental bond behavior in masonry elements externally reinforced with FRP laminates

PRELOADING EFFECT ON LOAD CAPACITY AND DUCTILITY OF RC BEAMS STRENGTHENED WITH PRESTRESSED CFRP STRIPS

Influence of Arching Mechanism in Masonry Walls Strengthened with FRP Laminates

13 TH C ANADIAN M ASONRY S YMPOSIUM H ALIFAX, C ANADA JUNE 4 TH JUNE 7 TH 2017 SEISMIC PERFORMANCE OF REINFORCED MASONRY WALLS STRENGTHENED

Università degli Studi di Roma Tor Vergata CIVIL ENGINEERING AND COMPUTER SCIENCE DEPARTMENT TERC TUNNELLING ENGINEERING RESEARCH CENTRE

AN IMPROVED COMPOSITE ANCHORING SYSTEM

INFLUENCE OF ARCHING MECHANISM IN MASONRY WALLS STRENGTHENED WITH FRP LAMINATES. Abstract

SEISMIC STRENGTHENING OF INFILLED RC FRAMES BY CFRP

A NEW CFRP STRENGTHENING TECHNIQUE TO ENHANCE PUNCHING SHEAR STRENGTH OF RC SLAB-COLUMN CONNECTIONS

STRENGTHENING OF MASONRY WITH NEAR SURFACE MOUNTED FRP BARS. Abstract

L Shaped End Anchors to Eliminate Premature Plate End Debonding in Strengthened RC Beams

OUT OF PLANE BEHAVIOR OF MASONRY INFILL WALLS RETROFITTED WITH A REINFORCED POLYMER GRID AND POLYUREA SYSTEM

CFRP STRENGTHENING OF CONCRETE BRIDGES WITH CURVED SOFFITS

AFRP retrofitting of RC structures in Japan

Retrofitting methods

Testing and analysis of masonry arches subjected to impact loads

Experimental research on strengthening of masonry vaults using FRP

Behaviour of deviated CFRP-Strips

Study on Strengthening of RC Slabs with Different Innovative Techniques

EXPERIMENTAL ANALYSIS ON THE SHEAR BEHAVIOUR OF RC BEAMS STRENGTHENED WITH GFRP SHEETS

INCREASED LOAD CAPACITY OF ARCH BRIDGES USING SLAB REINFORCED CONCRETE

The effectiveness of strengthening historic brick vaults by contemporary methods

POST-STRENGTHENING OF MASONRY COLUMNS BY USE OF FIBER-REINFORCED POLYMERS (FRP) Abstract

Bricktor and expanded metal in 10mm thickness mortar joints: a performance comparison

STRENGTHENING OF MASONRY BEAM WITH ECC AS BED JOINT

STRENGTHENING OF MASONRY ARCH BRIDGES: RESEARCH AND APPLICATIONS

COMPARISON OF IN-SITU AND LABORATORY TESTS OF BRICK MASONRY WALLS STRENGTHENED WITH CARBON FIBRE REINFORCED POLYMER FABRIC

Masonry Reinforcement for Arch Bridges

Structural reinforcement. TECHNOLOGY REINFORCEMENT by composite sistems for concrete, masonry,metal, wood FRP SYSTEM FRCM-SRG SYSTEM

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA

CIC2014. Concrete Innovation Conference

Experimental investigations on the influence of thermal elements on the structural stability of modern masonry walls

Experimental Study on Wall-Frame Connection of Confined Masonry Wall

IDEA OF HYBRID COLUMN WITH ENERGY ABSORPTION ELEMENT

UPGRADING SHEAR-STRENGTHENED RC BEAMS IN FATIGUE USING EXTERNALLY-BONDED CFRP

STRUCTURAL UPGRADING OF A BRICK MASONRY ARCH BRIDGE AT THE LIDO (VENICE)

EFEECT OF GFRP BELT TO THE FAILURE MODE OF CRACKED CONCRETE BEAMS STRENGTHENED USING GFRP SHEET

Flexural strengthening of reinforced concrete beams using externally bonded FRP laminates prestressed with a new method

Department of Strength of Materials and Engineering Structures. Technical University of Catalonia. Colom Terrassa, Spain

Figure 1: Construction of arch unit using pre-cast individual voussoir concrete blocks (Taylor et al, 2007)

Shear strengthening of RC deep beams with circular openings using externally bonded SFRP composites

Effect of prestressed CFRP plate location on behavior of RC beam strengthened with prestressed CFRP plate

EXPERIMENTAL STUDY ON FLEXURAL BEHAVIOR OF RC BEAMS STRENGTHENED WITH SMPM

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

Strengthening of infilled RC frames by CFRP

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

Numerical Analysis of Strengthening R.C Slabs with Opening using Ferrocement Laminates

FATIGUE BEHAVIOR OF CFRP-STRENGTHENED REINFORCED CONCRETE BRIDGE GIRDERS. Abstract

Experimental results on masonry wall anchored ties

On the mechanical behaviour of FRCM composites

EXPERIMENTAL STUDY OF THE FLEXURAL BEHAVIOUR OF LOW PERFORMANCE RC BEAMS STRENGTHENED WITH TEXTILE REINFORCED MORTAR

SEISMIC RETROFITTING OF REINFORCED CONCRETE BRIDGE FRAMES USING EXTERNALLY BONDED FRP SHEETS

PRESENTATION OF NIKER EU PROJECT

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

Behavior and Strength of Bearing Wall Strengthening by CFRP

Experimental Investigation of the Fire Resistance of Thin Hollow-Core Concrete Slabs with Simple Supports

Mechanisms of Bond Failure Between Existing Concrete and Sprayed Polymer Cement Mortar with CFRP Grid by Acoustic Emission

ULTRA-HIGH PERFORMANCE PLASTER (UHPPl) FOR SEISMIC REINFORCEMENT OF MASONRY WALLS

VAULTED STRUCTURES STABILITY CALCULATIONS

Accelerated ageing of textile reinforced concrete (TRC)

1337. Seismic response of beam-column joints rehabilitated with FRP sheets and buckling restrained braces

Strengthening Steel I-Beams by Welding Steel Plates before or While Loading

RESILIENT INFRASTRUCTURE June 1 4, 2016

Behaviour of UHPFRC-RC composite beams subjected to combined bending and shear

Fatigue flexural behaviour of corroded RC beams strengthened with CFRP sheets

MECHANICAL CHARACTERIZATION OF SANDWICH STRUCTURE COMPRISED OF GLASS FIBER REINFORCED CORE: PART 1

Effect of Bar-cutoff and Bent-point Locations on Debonding Loads in RC Beams Strengthened with CFRP Plates

PULLOUT CAPACITY BEHAVIOUR OF FRP-HEADED REBARS

INVESTIGATION OF STRUCTURAL MEMBERS WITH BASALT REBAR REINFORCEMENT AS AN EFFECTIVE ALTERNATIVE OF STANDARD STEEL REBAR

CONFRONTATION OF TEXTILE REINFORCED CONCRETE (TRC) WITH CARBON AND STAINLESS STEEL GRIDS FOR STRENGTHENING OF MASONRY

STRUCTURAL LAB. FACILITY AT IITG IN THE DIRECTION OF TRADITIONAL/LOCAL HOUSING

SEISMIC REHABILITATION OF REINFORCED CONCRETE BRIDGE COLUMNS IN MODERATE EARTHQUAKE REGIONS USING FRP COMPOSITES

Fundamental Study on Mechanical Behavior and Repairing Method of Corroded RC Beams Including Anchorage Damage 06_10431 Mai SAKAI

Basic types of bridge decks

Application of Tensioned CFRP Strip Method to an Existing Bridge

Textile Reinforced Concrete (TRC) for precast Stay-in-Place formwork elements

S&P ARMO-System FRCM Design Guidelines. Fiber Reinforced Cementitious Matrix

Finite Element Analysis of RC Beams Strengthened with FRP Sheets under Bending

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Function-integrated GFRP sandwich roof structure Experimental validation of design

Finite Element Analysis of R.C. Arches with Openings Strengthened by CFRP Laminates

EFFECTS OF SUPPORT CONDITIONS ON LINTEL-MASONRY INTERACTION

Transcription:

SAHC2014 9 th International Conference on Structural Analysis of Historical Constructions F. Peña & M. Chávez (eds.) Mexico City, Mexico, 14 17 October 2014 LABORATORY TESTS ON MASONRY VAULTS STRENGTHENED AT THE EXTRADOS Łukasz Hojdys 1, Piotr Krajewski 2 1 Cracow University of Technology Warszawska 24, 31-155 Cracow, Poland e-mail: lhojdys@pk.edu.pl 2 Cracow University of Technology Warszawska 24, 31-155 Cracow, Poland pkrajews@pk.edu.pl Keywords: Strengthening, Masonry, Arches, Vaults, Composite materials, TRM, Glass fibers, Experimental tests. Abstract. Research done in recent years showed that fiber-reinforced polymers and textilereinforced mortars are effective strengthening solutions for masonry structures. The use of externally bonded composites has become a more popular technique for strengthening historic masonry vaults and arches. Strengthening may be applied at lower, upper or both vault surfaces. The reasonable location of composite strengthening depends on the geometry of the vault and on possible loads, but also on the condition of the vault and the way of finishing its intrados. When a historic vault with frescoes or plasterwork is analyzed and needs to be strengthened, the only option for strengthening with composite materials is strengthening applied at the vault extrados. This paper deals with the experimental behavior of masonry vaults strengthened externally with a composite material. The thickness, internal span and rise of the vaults were 120 mm, 2000 mm and 730 mm, respectively. Masonry was made of solid clay bricks and lime mortar. The vaults were tested under a monotonic vertical load applied at a quarter span. An alkaliresistant coated glass fiber grid embedded in a cement-based matrix was used as the strengthening. The tensile strength of the glass grid specified by the manufacturer was about 45kN/m. All of the tested vaults were strengthened continuously at their extrados. Both ends of the strengthening above the abutments were either bonded to the masonry or anchored mechanically using steel plates to the concrete abutments. The main aim of the presented research was to determine the load-carrying capacity and to examine the failure modes of the tested specimens. All of the tested specimens failed due to fibers rupture. The strengthening system used in the presented research turned out to be an effective strengthening solution for masonry barrel vaults with frescoes or plasterwork.

Łukasz Hojdys, Piotr Krajewski 1 INTRODUCTION The use of externally bonded composites for strengthening masonry structures has been widely investigated in recent years. Carbon, glass, basalt or steel fiber reinforced composites improve the masonry flexural capacity and can successfully be used to strengthen masonry structures. The effectiveness of such a strengthening method was confirmed in many laboratory tests that were carried out on masonry arches and vaults strengthened with both fiberreinforced polymers (FRP) [1, 2, 3, 4] or cement-based composites (Textile Reinforced Mortar TRM, Fiber Reinforced Cementitious Matrix FRCM) [3, 6, 7, 8]. Strengthening applied at upper [1, 2, 4, 5, 7, 9], lower [1, 2, 4, 5, 10] or both surfaces [5, 6] of the arch/vault significantly increases the load-bearing capacity and changes observed collapse mechanism of the structure. Deciding on the location of the strengthening on historical vaulted structures depends not only on the geometry of the vault, the estimated loads and the technical condition of the structure, but also on the way of finishing its intrados. When a historic vault with frescoes or plasterwork is analyzed, locating the strengthening at the lower surface of the vault is usually not permitted from the point of view of architects and historians, and the only option is strengthening at the vault extrados. In this paper such vaults were taken under consideration. Research studies on vaults strengthened with glass or carbon grids were carried out in the last few years at the Cracow University of Technology in order to make recommendations for strengthening masonry vaults with composites. Barrel vaults of a geometry similar to the geometry of typical vaults that can be found in historic buildings in Cracow s Old Town were considered. This paper deals with the results of tests conducted on vaults strengthened continuously at their extrados with glass fibers. The main goal of the present study was to check the effectiveness of the strengthening method and to examine if fixing the ends of the strengthening grid to the vault s supports affects the behavior and load-bearing capacity of the vault. 2 TESTING PROCEDURE The tested barrel vaults were characterized by 125 mm thickness, a 2000 mm internal span, a 730 mm rise and a 1040 mm width (Fig. 1a). The masonry was made of solid clay bricks (250x125x65 mm 3 ) and pre-mixed lime mortar. The vaults were strengthened with a glass fiber grid, Fig. 2a (with a width of about 91 cm), embedded in a polymer-cement mortar this strengthening system is also known as the textile reinforced mortar system (TRM) [10, 11, 12]. Selected mechanical properties of the materials used in the tests are presented in Table 1. a) b) Figure 1: a) Geometry of the tested vaults, brick course numbering. b) Instrumentation arrangement, (dimensions in mm; LVDT displacement transducers). 2

Laboratory Tests on Masonry Vaults Strengthened at the Extrados All of the tested specimens were strengthened at their extrados. The strengthening was applied continuously between the first brick courses above the supports (from 1A to 1B see Fig. 1a). The ends of the glass fiber grid were not connected to the concrete supports only bonded to the masonry of brick courses 1A and 1B (specimens VG1, VG2 Fig. 3, VG3) or anchored mechanically to the supports using steel plates, Fig. 2b-c (specimen VG-An Fig. 4). Before strengthening, vaults VG1, VG2 and VG-An were tested as non-strengthened vaults up to the formation of a four-hinge mechanism [10, 13]. Then the initial geometry of the vaults was restored and they were strengthened with TRM. a) b) c) Figure 2: a) Glass fiber grid used in the study detail. b) Glass fiber grid arrangement above the abutment during application of the strengthening vault VG-An. c) View of the strengthening s anchorage on the abutment of vault VG-An. Tests were carried out 14 days after strengthening under a monotonic vertical load applied at a quarter span to the top of the vaults extrados. The load increased until failure of the vaults took place. During the tests load, both radial and vertical displacement of the vault were measured. The test setup and instrumentation arrangement are presented in Fig. 1 [7, 10]. Table 1: Selected mechanical properties of materials used in the tests. Clay brick - compressive strength (N/mm 2 ) 24.4 Lime mortar at 28 days - compressive strength (N/mm 2 ) 1.1 Cement-polymer mortar - compressive strength at 14 days (N/mm 2 ) - compressive strength at 28 days (N/mm 2 ) - bond strength by pull-off (to concrete) (N/mm 2 ) Glass fiber grid - tensile strength /specified by manufacturer/ (N/mm) 45 25.0 31.8 >2.4 3

Łukasz Hojdys, Piotr Krajewski 3 TEST RESULTS 3.1 Specimens VG1, VG2, VG3 Observations conducted during tests of vaults strengthened with glass grids not connected to the abutments were similar. In the initial stage of the experiments (at a load of 7-9 kn), cracks appeared under the point of loading on the intrados. At a load of 22-23 kn the first cracks in the strengthening layer were observed, which resulted in a considerable reduction of the stiffness of the vaults (Fig. 5a). As the load was increasing, further cracks on the extrados (in the strengthening above the mortar joints between brick courses 8A and 18) appeared. In the final stage of the tests, cracks in the mortar joints under brick courses 1A and 1B occurred. a) b) c) d) e) Figure 3: Vault VG2 (originally named S03W): a)-c) cracks and hinges developed, d) crack at the extrados ruptured glass fibers, e) failure mechanism. Finally, the composite (strengthening layer) near brick course 12A exceeded its tensile strength and the vaults collapsed. The maximum loads noted during the tests were 31.0 kn, 28.2 kn and 34.0 kn for vaults VG1, VG2 and VG3, respectively. The typical failure mechanism observed during these tests is shown in Fig. 3 and Fig. 6a. 4

Laboratory Tests on Masonry Vaults Strengthened at the Extrados 3.2 Specimen VG-An Similarly as in tests on vaults VG1-VG3, the first crack appeared on the intrados under the point of loading. Afterwards, at a load of 23-30 kn, cracks developed at the vault s extrados in the strengthening layer and at the intrados between the first brick course and abutment A. In the final stage of the test (when the load exceeded 30 kn), cracks were observed in the strengthening layer above abutment B and several other cracks were observed at the extrados between brick courses 9A and 15A. a) b) c) d) e) Figure 4: Vault VG-An (originally named S04W): a)-d) cracks and hinges of the collapse mode, e) failure mechanism. Finally, at a load of 31.4 kn, glass fibers between brick courses 12A and 13A ruptured, then the fibers connected to abutment B ruptured (near brick course 1B) and the vault collapsed. Initially, the structure of the vault consisted of two masonry curved bars connected together by means of a hinge (at the extrados under the point of loading) with hinged support above abutment A and fixed support above abutment B. The structure was a stable one. After the formation of the third hinge at the intrados of the vault after rupture of the strengthening between brick courses 12A and 13A the vault changed to a three-hinged vault/frame (still stable). Immediately after the third hinge formation the fibers above support B ruptured and the structure changed to a mechanism. This happened suddenly because the actuator was load-controlled (load-controlled test) and the load-bearing capacity of the threehinged structure (with hinges between brick courses 12B/13B, 12A/13A and above support A) was lower than before. 5

Łukasz Hojdys, Piotr Krajewski 4 DISCUSSION AND CONCLUSIONS When comparing the results of the tests presented above with the test performed on nonstrengthened vaults, discussed among others in [7, 10, 13], it must be noted that the adopted strengthening system is an effective solution for masonry vaults and arches (Fig. 5b). Vaults without strengthening loaded at a quarter span typically failed due to the formation of the four-hinge mechanism [10, 13] at a load of about 4.5 kn. Continuous strengthening at the extrados of the vault prevented the formation of hinges at the vault s intrados and prevented (until the glass fibers ruptured) failure due to the four-hinge mechanism formation [4]. Therefore, the load-carrying capacity of the strengthened vaults increased to more than 28 kn (Fig. 5b). a) b) Figure 5: a) Load vertical displacement (at the point of loading) curves for the tested vaults. b) Maximum loads for the tested vaults summary. a) b) Figure 6: Failure mechanisms observed during the tests: a) vault VG2, b) vault VG-An. The strengthening of vaults as discussed here was treated above the abutments in two different ways. The strengthening of vaults VG1-VG3 was applied continuously between the first brick courses and was not connected to the abutments. Thus hinges could freely develop between brick courses 1A or 1B and the abutments. The vaults collapsed due to fibers rupture. In the case of vault VG-An, the strengthening was anchored to the supports. Consequently, during the test the anchorage (Fig. 2b-c) resisted the possible negative bending moment at support B, prevented rotation of the vault (around abutment B) and prevented sliding (along abutment A). It can be concluded that vault VG-An collapsed due to glass fibers rupture be- 6

Laboratory Tests on Masonry Vaults Strengthened at the Extrados tween brick courses 12A and 13A and an almost simultaneous rupture of the fibers connected to support B. It was not possible to determine the load-bearing capacity of vault VG-An after rupture of fibers 12A/13A and just before rupture of the fibers above support B because the test was load-controlled. There was no significant increase in the load-bearing capacity of vault VG-An as compared to vaults VG1 and VG2 (Fig. 5b) these three vaults were tested before strengthening. The anchorage of the strengthening at the abutments had a negligible effect on the obtained failure loads and the observed collapse mechanisms (Fig. 6). During the tests, higher stiffness of vault VG-An as compared to vaults VG1 and VG2 was observed in the first stage of the tests (before the first crack in the strengthening layer occurred). As cracks at the extrados appeared, a clear reduction of all of the tested vaults stiffness was observed (Fig. 5a). It should be noted that the first cracks in the strengthening layer appeared at a load of about 23 kn for all of the tested vaults (Fig. 5a). Although the tests presented here were carried out on a limited number of vaults, the results show that continuous strengthening with TRM materials at the extrados should be considered during restoration works performed on masonry vaults, especially in the case of vaults with frescoes or plasterwork. ACKNOWLEDGMENTS The materials of the strengthening system were supplied free of charge by Mapei Polska Sp. z o.o. Laboratory tests were performed at the Cracow University of Technology, Poland. The authors gratefully acknowledge Prof. Z. Janowski for his support throughout this work. REFERENCES [1] M.R. Valluzzi, M. Valdemarca, C. Modena, Behavior of brick masonry vaults strengthened by FRP laminates, Journal of Composites for Construction, 5(3), 163-169, 2001. [2] P. Foraboschi, Strengthening of masonry arches with Fiber-Reinforced Polymer strips, Journal of Composites for Construction, 8(3), 191-202, 2004. [3] S. Briccoli Bati, S. Rovero, U. Tonietti, Strengthening masonry arches with composite materials, Journal of Composites for Construction, 11(1), 33-41, 2007. [4] D. Oliveira, I. Basilio, P. Lourenco, Experimental Behavior of FRP Strengthened Masonry Arches, Journal of Composites for Construction, 14(3), 312-322, 2010. [5] A. Borri, P. Casadei, G. Castori, J. Hammond: Strengthening of brick masonry arches with externally bonded steel reinforced composites, Journal of Composites for Construction, 13(6), 468-475, 2009. [6] Ł. Bednarz, A. Górski, J. Jasieńko, E. Rusiński, Simulations and analyses of arched brick structures, Automation in Construction, 20, 741-754, 2011. [7] Ł. Hojdys, Z. Janowski: Strengthening of masonry vaults with glass grids (in polish), Technical Transactions, 3-B, 71-91, 2011. [8] L. Garmendia, P. Larrinaga, D. García and I. Marcos: Textile-reinforced mortar as strengthening material for masonry arches, International Journal of Architectural Heritage, 8(5), 627-648, 2014. 7

Łukasz Hojdys, Piotr Krajewski [9] L. Garmendia, J.T. San-José, D. García, P. Larrinaga, Rehabilitation of masonry arches with compatible advanced composite material, Construction and Building Materials, 25, 4374-4385, 2011. [10] Ł. Hojdys, P. Krajewski, Behavior of masonry arches strengthened with TRM, 7 th International Conference on Arch Bridges (ARCH 13), 739-746, 2013. [11] Ł. Hojdys, P. Krajewski, Experimental tests on strengthened and unstrengthened masonry vault with backfill, 8 th International Conference on Structural Analysis of Historical Constructions (SAHC 2012), 668-674, 2012. [12] Ł. Hojdys, P. Krajewski, Experimental tests on strengthened masonry vaults, Applied Mechanics and Materials, 578-579, 1396-1399, 2014. [13] P. Krajewski, Ł. Hojdys, Experimental studies on buried barrel vaults, International Journal of Architectural Heritage, DOI:10.1080/15583058.2013.860499 (in press). 8