Technical System Catalogue Modular PDU (PSM)

Similar documents
PSM (Power System Module / PCU) DK DK DK DK

PSM metering bar for CMC III

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

WIND ENERGY HELLO WIND. Electrical solutions for wind energy plants. + + COMPONENTS + + CONNECTION TECHNOLOGY + + PLANNING

Model KB 23 Cooling incubators with compressor technology

BCMS Branch Circuit Monitoring Solutions JCOMM & BCMS Hub

INSULATION MONITORING RELAIS

Model BF 720 Incubators Avantgarde.Line with forced convection

Model FD 23 Drying and heating chambers Classic.Line with forced convection

Model KT 115 Cooling incubators with thermoelectric cooling

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

Model KB 720 Cooling incubators with compressor technology

Installation & Calibration

HRI-R22t series GENERAL FUNCTIONS AND OPERATORS - LEGENDA INSULATION MONITORING VERSIONS FOR USE IN MEDICAL ROOMS

EGA4 Combustion Analyzer Providing the latest technologically advanced instrumentation for combustion service engineers, installers & technicians

Online data sheet MAC800 CUSTOMIZED ANALYZER SYSTEMS

Model BF 260 Incubators Avantgarde.Line with forced convection

LSA-PLUS Series 2. Connection and Disconnection Modules and Accessories. 1 st Edition

Model BF 56 Standard-Incubators with forced convection

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications

HS-429 Vibration Trip Manual

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:

User Manual. Precision Balances XSR models

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

Environmental simulation chamber for cyclical temperature

LSA Rating Table Low Voltage Alternators - 4 pole

Fixed Demand (Block Demand) The utility company sends a signal to synchronize the start of the Maximum Demand period.

LSA Connecting Technology. LSA Connecting Technology Distributor Cabinets and Boxes Accessories

Siemens Controls. The power distribution board that sets new standards. SIVACON S4 safe, cost-efficient and flexible SIVACON

Table of contents. 1. Introduction

FIXED-WINDOW POWER DEMAND CONTROLLER BY ENERGY PULSES CVM-R8D-CPP INSTRUCTION MANUAL

UPS Electrical Design and. Installation. critica POWER SUPPLIES

AirBench EX Operation and Maintenance

Switch Disconnectors with Fuses

Power IT Compact Secondary Substations, CSS. Technical catalogue for sheet steel substations

KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions

Field case for temperature transmitter Model TIF11

3363 en / e

AS950 ALL-WEATHER REFRIGERATED SAMPLER

sivacon Safety Embedded in Supreme Design: The Power Distribution Board, that sets new standards.

MATERIAL SPECIFICATION FOR UNINTERRUPTIBLE POWER SUPPLY SYSTEMS FOR LED TRAFFIC SIGNALS

CLV 430/431/432. Bar Code Scanner

LOTOS. Optical 3D measuring systems K O C O S A U T O M A T I O N [ ENG ]

POWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A.

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

Critical POWER Supplies Projects Support

SPECIFICATION FOR APPROVAL

User Manual. Precision Balances and Comparators XPR models

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Digital Loop Carrier System

Using the PPM2 Portable Trace Moisture Transmitter

MPM 100 Monitor Product Description Guide

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM Digital Loop Carrier System

R U-Box Housing with Cable Grommet Screen

IP/V24 WALLBOARD 2 x 16 digits TECHNICAL MANUAL AUTHOR DATE REFERENCE. V. Bafour 23/01/2008 D

PowerEnergy MCC. Designed by the specialist for accidental arc fault protection!

Electrical point heating systems for extreme environmental conditions

LED light engine / OLED LED compact. Module EOS P211-4 Module EOS

SmartTouch. Truly smart flue gas measurement. The new testo 300 flue gas analyser with smart-touch technology.

AS950 REFRIGERATED SAMPLER

4-Beam-Turbidity Meter ITM-4

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

Bedhead Service Systems. Instructions for Use. July 2016 ASF-18 (0)

42U SmartRack White Standard-Depth Rack Enclosure Cabinet with doors, side panels & shock pallet packaging

Operating Manual. Wärtsilä JOVYTEC L 6kVA 10kVA. BAX 3297_en

SABRE P MODEL PD603 PROCESS METER Instruction Manual


IMPAC Infrared Thermometers

Equipment Information

SECTION Inline ULTRASONIC FLOW METERS

APC by Schneider Electric MGE GALAXY 9000 Uninterruptible Power Supply Guide Specifications 800/900 kva to 4800/5400 kva Parallel UPS, three-phase

SitePro. Uninterruptible Power Supply. Technology for the Digital World

The most Advanced & Productive Pick/Put to Light System Ever Developed.

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

OptiLine 70. Service Poles. Technical and Material data

Multi Ejector Solution TM for R744 (CO 2 ) Type - CTM 6 High Pressure (HP)

FITOCLIMA WALK-IN STABILITY

3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M / 00 B

FITOCLIMA WALK-IN STABILITY

Multi Ejector Solution TM for R744 (CO 2 ) Product type - CTM 6 Low Pressure (LP)

Sensor Cartridge SC2 for toxic gases and oxygen

Sensor Cartridge SC2 for toxic gases and oxygen

EuroFID Total Hydrocarbon Analyzer

PROYECTOR KOKOH UNE EN IK10 IP66

It s All a Matter of TechNiQ. NiQ: Our latest generation of energy-saving motors.

Because you can t manage what you don t measure usa.siemens.com/hvacr

NETbox Wall Mounting CABINETs

The ALS Generation. The labelling units for Your Product Identification

Model FDL 115 Safety drying chambers for limited quantities of solvent

madur GA21p-EN-v portable gas analyser

BOGE AIR. THE AIR TO WORK. CONTROLS

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Technical System Catalogue TS 8 Baying Systems

LIQUID METER TYPE FMO

New Measurement Engineering for the Domestic Installer and Heating Contractor

Access Wallbox Cabinet System

SMARTSCAN 8000 SERIES MUTE MODULES Series Mute Accessories Installation Sheet ( CD174A and CD174B )

Transcription:

Technical System Catalogue Modular PDU (PSM)

Benefits of PSM busbars at a glance Modular configuration, flexibly extendible Redundant designs in busbars are supported Vertical mounting in the rack without loss of U space Configuration changes are supported at any time with the system operational by replacing the module Shock-hazard-protected assembly of the power distribution Choose from different connection types and phase currents Extensive range of accessories for connection cables and mounting kits Integral energy measurement and remote monitoring via CMC III (with special PSM measuring bars) 2

Modular PDU (PSM busbars) The PSM system is a unique, modular power distributor for integration into IT network and server racks. The configuration (type and quantity of output slots) can be modified to accommodate altered requirements at any time, even whilst operational. The modular PDU comprises a support rail which is fitted vertically into the IT rack. This PSM busbar has individual module slots into which various PSM plug-in modules may be integrated. These plug-in modules are available in a range of output pin patterns and functions. Alongside purely passive distribution modules, special active modules with switching and measuring functions may also be integrated into the PSM busbar. The electrical connection is made using the preassembled plug&play connection cable available as an accessory, but also can be made directly by a qualified electrician using the Wago X-COM connector included in the supply pack. Some versions of PSM busbars, including all 32 A versions, have a fixed, prefitted connection cable with CEE connector (to /EN 60 309). A range of mounting kits are available for flexible rack mounting, so as to accommodate varying requirements such as vertically hinged installation or quick installation in the TS IT rack. A B Each plug-in module picks off a phase on the support rail, either from infeed A or from the redundant infeed B, depending on the direction of connection. Criteria for selecting the correct PSM busbar Enclosure height No. of phases (single or three-phase) No. of infeeds No. of required PSM plug-in modules Type of infeed (e.g. fixed infeed) Additional measurement and management functions required Phase current (16 A, 32 A) 3

Function Model No. 7856.005 7856.006 7856.008 7856.010 7856.020 7856.321 7856.323 7856.050 7856.053 Minimum height of rack (mm) 2000 2000 2200 1200 2000 2000 2000 2000 2000 Type of connection/length Fixed/3 m Fixed/3 m WAGO jack WAGO jack WAGO jack Fixed/3 m Fixed/3 m WAGO jack Fixed/3 m Connector CEE CEE Various Various Various CEE CEE Various CEE No. of infeeds 1 2 2 2 2 1 1 2 1 No. of phases 3 3 3 3 3 1 3 3 1 Phase current (A) 16 16 16 16 16 32 32 16 32 Various connection cables, also for single-phase connection No. of PSM module slots 7 7 8 4 7 6 6 6 6 Integral energy measurement of voltage, current, active power, apparent power, active energy, power factor, mains frequency Measurement accuracy (U, l, f, P, S) 2% 2% Measurement accuracy (E/kWh) 1% 1% Graphic display for visualising the measurements (24 V DC required) CAN bus interface for connecting to CMC III system Web server (IPv4, IPv6, SNMP, SSH) via CMC III (PU III - 7030.000) E-mail forwarding of exceeded limits and alarms (CMC III required) Operating temperature ( C) 5 45 Ambient humidity % (non-condensing) 10 90 Protection category IP (to 60529) IP 20 Approvals CE CE CE CE/VDE CE/VDE CE CE CE CE 4

Modular PDU (PSM plug-in modules) Choose from a wide range of PSM plug-in modules to configure the PSM busbar with the required output slots. The modules are snap-fastened into the PSM busbar without the use of tools, and the slots are then available for the equipment. It may be assembled while operational and connected to the power supply (but only off-load). A range of different pin patterns and functions are available (e.g. switching the outputs and power measurement), so that every PSM busbar can be configured individually depending on the preferred application. Data communication and network connection occur via the CMC III. Together with the CMC III and in conjunction with other CMC III sensors e.g. for ambient parameters such as temperature and humidity, this creates a comprehensive monitoring solution. PSM plug-in modules (passive, distribution only) Model No. 7856.080 7856.082 7856.100 7856.240 7856.230 7856.070 7856.220 7856.090 7856.120 7856.191 7859.120 7859.130 Occupied slots in PSM busbar 1 Pin pattern (type) C13 C13 CEE 7/3 type F CEE 7/3 type F C19 C13 C13 CEE 7/3 type F CEE 7/5 type E Number of outputs 6 6 4 4 4 6 4 4 4 4 6 4 Colour of slots black red black red black black black black black black black black Lockable connectors (optional) Miniature fuse per output Thermal overload protection Optical LED current display (total current) Switchable outputs (via CMC III) Current measurement per module/output Dimensions W x H x D mm 52 x 250 x 45 Operating temperature ( C) 5 45 Ambient humidity % (non-condensing) 10 95 Material Extruded aluminium section/plastic Approvals CE CE CE/VDE CE CE CE CE CE CE CE CE CE T 23 type J C13 C19 5

PSM plug-in modules with power monitoring and output switching function As well as passive PSM plug-in modules, which merely distribute power via various types of output slots, there are also smart PSM plug-in modules with additional functions. These modules are ideally suited for retrofitting a power and load management system and provides remote switching functionality if the PSM busbar has already been installed and commissioned. There is a choice of three modules with identical functions but different slot configurations. Data forwarding (or switching function) occurs with the aid of a CMC III PU or PU compact. The modules have a CAN bus interface for direct connection. One LC display per module is available for local display in the rack. The colour of the background lighting visualises the various system states and exceeded limits clearly and intelligibly. LEDs on the slots visualise the current switching status. Functions: Measurement of power consumption per module Output slots may be switched individually and in groups LEDs per slot to visually indicate the switching status LC display with multi-coloured backlight for local display Adjustable limits for voltage, current and active power Configurable overload detection per module High level of measurement accuracy Alarm signalling via the display Alarm management via CMC III (e.g. e-mail or text message) Visualisation of the switching status on the CMC III website and RiZone Up to 16 PSM modules on one CMC III PU (per IP address) Rights management via CMC III (e.g. restriction of the switching function) Facilitates the implementation of requirements to EN 16001/ISO 50001 and EN 50600-2-2 Stable aluminium section with plastic socket inserts Supports universal connector locking of the C13 and C19 slots Supports the closure of unneeded C13 and C19 slots PSM module is easily fitted into and removed from the PSM busbar, for use at different locations Compatible with the European PSM busbar range Depending on the PSM busbar, up to four modules per bar may be fitted 6

PSM plug-in modules with power monitoring and switching function Product characteristics Unit PSM module type Model No. 1 pc(s). 7859.410 7859.420 7859.430 No. of C13 slots 8 2 2 No. of C19 slots 4 No. of earthing-pin slots (CEE 7/3 or type F) 4 Total no. of all switchable outputs 8 6 6 No. of slots required in the PSM busbar 2 Module dimensions (W x H x D) mm 53 x 500 x 45 Section Aluminium, anodised Plastic PA6 GF 30 V1 Electrics No. of infeeds per module Qty. 1 Input voltage V AC 230 Input voltage, tolerance V AC 207 250 Rated current A 16 Distribution output per module (at 230 V) W 3680 Power supply (via CMC III system, alternatively with power pack 7201.210) V DC 18-24 Functional overview Measurement functions Per module Switching functions Per output slot Relay type Dual coil/bistable Relay switching load VA 4000 Display (LC matrix display with coloured backlight) Per module LEDs (blue) to indicate switching status Per output slot Status LEDs - CAN bus communication 4 pc(s). Per module Keys for operation & configuration 4 pc(s). Per module Location sensor for correct display and Web view in 90 increments Connector lock (optional, for C13 & C19 slots) 20 pc(s). 7955.020 Measurement functions Voltage (V), current (A), frequency (Hz) Active power (kw), active energy (kwh) Reactive power (kvar), reactive energy (kvarh) Apparent power (kva), apparent energy (kvah) Power factor (cos?), crest factor (amplitude factor) Operating hours meter (d. h. min) Measurement accuracy % +/ 1 Resettable measurement functions/reset via software/interval measurement Active energy (kwh) Operating hours meter (h) Threshold values (warning/alarm), freely configurable Voltage, current, power Connectivity / management functions (in conjunction with CMC III) Maximum no. of modules that may be used per CMC III Processing Unit Qty. 16 Maximum no. of modules that may be used per CMC III Processing Unit Compact Qty. 4 CAN bus for direct linking to CMC III system pc(s). 2 (RJ45) Network functionality (only in conjunction with CMC III system) IPv4, IPv6, SNMPv3, Modbus/TCP, OPC-UA Ambient conditions Operating temperature C +5 +50 Operating temperature (at max. 8 A per output slot) C +5 +60 Storage temperature C -20 +70 Ambient humidity (non-condensing) rel. humidity, % 10 90 Maximum installation height m 2000 Overvoltage category II Contamination level 2 Protection class ( 60529) IP 20 Approvals and standards Approval Standards (excerpt) CE, RoHS II Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU EN 50600-2-2 EN 60 950 7

Control and monitoring with CMC III management system The CAN bus connection with the CMC III monitoring system is made for control and remote management of the PSM busbars, PSM measurement modules and MID measurement modules (482.6 mm (19") inline meter). The CMC III provides a connection to the outside world using a range of protocols (IPv4, IPv6, SNMP, OPC-UA, Modbus/TCP, SSH etc.) In this way, multiple busbars and PSM modules, even distributed across several racks, can be combined and managed under one IP address. Logical links with other CMC III sensors (e.g. temperature, humidity, smoke alarm etc.) are also supported. The benefits of PSM plug-in modules at a glance: May be installed and replaced at any time, even while live, without specialist knowledge Various pin patterns for every application Modules with switching and measurement functions, also suitable for retrofitting Versions with miniature fuses and load display via LED are available VDE-tested (some versions) Compact design, despite modularity IP network IP network + + Type of cabling: 230 V/400 V mains 24 V DC, buffered CMC III CAN bus Network/IP/SNMP Type of cabling: 230 V/400 V mains 24 V DC, buffered CMC III CAN bus Network/IP/SNMP PSM measurement modules, connection to CMC III Max. 8 modules per CAN bus Connection of PSM measurement modules to the CMC III PU and network 230 V supply to the PSM modules via PSM busbar! PSM measurement bars, connection to CMC III Max. 4 PSM measurement bars per CAN bus Connection of PSM measurement bars to the CMC III PU and network 8

Visual load management with PSM In many cases, fast identification of the module or phase load is useful. However, companies often shy away from investing in complex measurement technology. For such cases, special PSM modules are available which visualise the current rating of all connected equipment without the need for additional accessories. These modules can be integrated into any existing PSM busbar, or replace existing PSM modules. There are two versions available with 6 x C13 (7859.120) or 4 x C19 (7859.130) output slots. Using these PSM modules with LED current display allows you to visualise the load distribution in the PSM busbar. You can see at a glance which PSM module can accommodate further equipment without causing a phase overload. Once the prescribed load limit of the module is reached, any remaining slots may be sealed with optionally available C13 or C19 covers to prevent mistakes being made in the hectic environment of data centre operation. The limits are preset in the factory and cannot be altered. Current limits: 0 7 A (green), 7 13 A (yellow) and >13 A (red) These PSM plug-in modules with LED load display are ideally suited for retrofitting to existing PSM installations to enhance the reliability of the supply. To match the LED modules with load display, C13/C19 slot covers are also available, to prevent overloading with additional equipment. The cover is easily removed with a release tool if necessary. Ingeniously simple: Optical load indicators Phase loads are clearly visible at all times. No more worries about unnoticed overloading or unbalanced power distribution in the rack. PSM plug-in module with load display Covers for secure load management 9

PSM MID measurement module for 482.6 mm (19") installation This measurement device is connected into the connection cable (infeed) of the equipment or the power distributor, and records the consumed active energy with 1% accuracy. MID approval means that the module is licensed for use in the European Union for energy billing purposes. As well as measuring energy, it also measures other performance data such as voltage, current, active and apparent power, power factor, and neutral conductor current. Measurement of the neutral conductor current aids the reliable detection of asymmetries (different phase utilisation levels) in power distribution. The meter is fitted horizontally in the 482.6 mm (19") level. There are two versions available, for 16 A and 32 A phased current, which are connected using cable sets available as accessories. A special preassembled connection cable set is available for connecting to PSM busbars with Wago X-COM connectors. In this way, a power distributor without measurement capabilities is quickly and easily extended. Approval for energy billing purposes is valid for 8 years and can be extended for a further 8 years by recalibrating. What is MID? MID stands for Measurement Instruments Directive and regulates 10 types of measurement equipment based on EU Directive 2004/22/EC. The aim is to harmonise the approval of measurement equipment in the Member States. However, country-specific regulations (such as the Calibration Act in Germany) continue to apply. MID regulates the entire manufacturing process, from development, to production, through to final testing of the measurement equipment. General and device-specific performance requirements are defined in the MID, which the manufacturer must comply with. Following successful testing, the MID-approved devices are labelled and may be sold throughout the EU. + + Benefits of the MID measurement module: Easy to install active energy meter based on the plug & play system Variants for 16 A and 32 A phase current Two independent circuits in each case (3-phase) Pre-assembled connection cable with CEE connector / coupling Simple, flexible assembly Billable MID measurement units CAN bus for connection to CMC III system Extensive monitoring functions (via CMC III) High-MTBF and measurement accuracy of 1% Energy-efficient electric design minimal inherent power consumption High-quality sheet steel enclosure IP mains IT network/server rack IT rack with redundant power supply (PSM or PDU basic ) Measurement via MID inline meter Type of cabling: 230 V/400 V mains 24 V DC, buffered CMC III CAN bus Network/IP/SNMP Serial connection CMC III power pack (redundant design with 2 power packs optionally supported) CMC III PU/PU Compact Circuit A Max. 8 MID modules Circuit B 10

Enclosures Power Distribution Climate Control IT Infrastructure Software & Services You can find the contact details of all Rittal companies throughout the world here. XWW00090EN1603 www.rittal.com/contact