Originally Issued: 03/13/2015 Revised: 03/10/2017 Valid Through: 03/31/ Description

Similar documents
Originally Issued: 04/15/2011 Revised: 04/05/2018 Valid Through: 04/30/ Materials

Originally Issued: 05/16/2012 Revised: 05/31/2018 Valid Through: 05/31/2019

Originally Issued: 03/31/2017 Valid Through: 04/30/2018

Originally Issued: 02/11/2011 Revised: 02/23/2018 Valid Through: 02/28/2019

Originally Issued: 03/27/2015 Revised: 10/17/2017 Valid Through: 03/31/2018

Originally Issued: 11/12/2013 Revised 12/29/2017 Valid Through: 11/30/2018

Originally Issued: 09/19/2014 Revised: 10/17/2017 Valid Through: 11/15/2017

Originally Issued: 12/09/2014 Revised: 10/01/2018 Valid Through: 11/30/ Design:

Originally Issued: 07/25/2014 Revised: 02/24/2017 Valid Through: 07/31/2017

Originally Issued: 04/24/2018 Valid Through: 04/30/ Design

Originally Issued: 07/25/2014 Revised: 07/31/2018 Valid Through: 07/31/2019

Originally Issued: 11/04/2016 Revised: 11/28/2017 Valid Through: 11/30/2018

Originally Issued: 09/07/2016 Revised: 09/28/2018 Valid Through: 09/30/2019

Originally Issued: 09/10/2015 Revised: 10/12/2017 Valid Through: 09/30/2019

Originally Issued: 01/13/2012 Revised: 02/05/2018 Valid Through: 02/28/2019

Originally Issued: 04/2015 Valid Through: 04/2016

Originally Issued: 05/04/2016 Revised: 05/26/2017 Valid Through: 05/31/2019

Originally Issued: 05/20/2013 Revised: 07/07/2017 Valid Through: 05/31/ Design

Originally Issued: 05/18/2018 Valid Through: 05/31/2019

Originally Issued: 09/16/2010 Revised: 09/15/2017 Valid Through: 09/30/ Design:

Originally Issued: 08/31/2008 Revised: 10/05/2018 Valid Through: 08/31/2019

Originally Issued: 03/31/2017 Revised: 03/15/2018 Valid Through: 03/31/2018

Originally Issued: 11/30/2015 Revised 10/05/2018 Valid Through: 11/30/2019

Originally Issued: 09/19/2014 Revised: 10/02/2015 Valid Through: 09/30/2016

Originally Issued: 08/22/2014 Revised 03/10/2017 Valid Through: 08/31/2017

Originally Issued: 03/08/2013 Revised: 03/14/2017 Valid Through: 03/31/2019

Originally Issued: 11/24/2010 Revised: 01/20/2017 Valid Through: 11/30/ Design

Originally Issued: 11/06/2017 Valid Through: 11/30/2018

Originally Issued: 07/29/2014 Revised: 07/31/2018 Valid Through: 07/31/2019

Originally Issued: 05/03/2013 Revised: 06/06/2016 Valid Through: 05/31/2017

Originally Issued: 08/03/2017 Revised: 02/01/2019 Valid Through: 08/31/2019

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

Report No Originally Issued: 05/2013 Revised: 07/17/2014 Valid Through: 05/2015

Originally Issued: 04/17/2015 Valid Through: 04/30/2016

Originally Issued: 12/18/2015 Revised: 04/14/2017 Valid Through: 12/31/2017

Originally Issued: 2/12/2016 Revised: 07/28/2017 Valid Through: 2/28/2018

CITY OF LOS ANGELES CALIFORNIA

Originally Issued: 01/01/2014 Revised: 03/15/2018 Valid Through: 01/31/2019

Originally Issued: 02/01/2019 Valid Through: 02/28/2020

Originally Issued: 05/01/2015 Revised: 09/01/2017 Valid Through: 05/31/2018

Originally Issued: 03/28/2014 Revised: 05/25/2017 Valid Through: 03/31/2018

IAPMO UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR JOIST HANGERS AND MISCELLANEOUS CONNECTORS

Originally Issued: 03/10/2017 Revised: 03/30/2019 Valid Through: 03/31/ Design

Originally Issued: 05/06/2010 Revised: 05/31/2018 Valid Through: 05/31/2019

Originally Issued: 04/18/2014 Revised: 05/02/2018 Valid Through: 04/30/2019

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

Originally Issued: 03/28/2014 Revised: 05/19/2017 Valid Through: 03/31/ General

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: SKYCO SKYLIGHTS 2995 AIRWAY AVENUE, SUITE B COSTA MESA, CALIFORNIA 92626

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

DIVISION: WOOD, PLASTICS, AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

ESR ICC Evaluation Service, Inc. Reissued July 1, 2006 This report is subject to re-examination in two years.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

DIVISION: 07- THERMAL AND MOISTURE PROTECTION Section: Thermal Insulation REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

ESR-2604* Reissued January 1, 2011 This report is subject to renewal in two years.

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

Originally Issued: 09/16/2010 Revised: 05/17/2018 Valid Through: 09/30/2019. ACI , -08, or -05, the head is considered part of the bar.

Originally Issued: 03/21/2014 Revised: 04/12/2018 Valid Through: 03/31/2019

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICE EVALUATION CRITERIA FOR

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

3.0 DESCRIPTION. Division: Thermal and Moisture Protection Section: Thermal Insulation

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

REPORT HOLDER: NO-BURN, INC HIGH STREET WADSWORTH, OHIO (800)

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

3.1 General. 3.2 Materials. 4.1 General. Page 1 of 6

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: KINGSPAN LIGHT + AIR LLC

Originally Issued: 03/10/2017 Revised: 08/24/2018 Valid Through: 03/31/ Design

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

Originally Issued: 01/16/2015 Revised: 09/20/2018 Valid Through: 01/31/2019

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

Originally Issued: 01/16/2015 Revised: 01/30/2018 Valid Through: 01/31/2019

Originally Issued: 03/21/2014 Revised: 10/18/2018 Valid Through: 03/31/2019

Code Compliance Research Report CCRR-0187

Originally Issued: 09/30/2011 Revised: 09/15/2017 Valid Through: 09/30/ Design:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

Code Compliance Research Report CCRR-0118

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Originally Issued: 01/26/2010 Revised: 02/27/2017 Valid Through: 02/28/ Fasteners

ESR-1461 Reissued February 1, 2014 This report is subject to renewal March 1, 2015.

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

Originally Issued: 02/02/2009 Revised: 11/09/2017 Valid Through:02/28/2019

REPORT HOLDER: MASTER MARK PLASTICS PRODUCTS 210 AMPE DRIVE PAYNESVILLE, MINNESOTA EVALUATION SUBJECT:

Originally Issued: 01/26/2010 Revised: 01/05/2018 Valid Through: 02/28/ Design:

Code Compliance Research Report CCRR-0262

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF TILES REPORT HOLDER: GERARD ROOFING TECHNOLOGIES EVALUATION SUBJECT:

Transcription:

EVALUATION SUBJECT: TILE FLASHING SYSTEM REPORT HOLDER: EcoFasten Solar 4741 W. Polk Street, Ste. 4 Phoenix, AZ 85043 Phone: 888-766-4273 brian@alpinesnowguards.com CSI DIVISION: 06 WOOD AND PLASTICS CSI Section: 06 25 23 Wood, Plastic, and Composite Fastenings 1.0 SCOPE OF EVALUATION 1.1 Compliance to the following codes & regulations: 2015, 2012 and 2009 International Building Code (IBC) 2015, 2012 and 2009 International Residential Code (IRC) 1.2 Evaluated in accordance with: IAPMO UES Evaluation Criteria for Joist Hangers and Miscellaneous Connectors, EC002, adopted January 2016 Acceptance Criteria for Roof Flashing for Pipe Penetrations (ICC-ES AC286), approved April 2010 1.3 Properties assessed: Structural Water Penetration 2.0 PRODUCT USE EcoFasten Solar s Tile Flashing System are mounting assemblies used to attach solar panels and other types of equipment to the rafters of roofs with low-profile barrel shaped tile or flat tile roof coverings in accordance with IBC Sections 1509 and 1511. 3.0 PRODUCT DESCRIPTION 3.1 Product information 3.1.1 Tile Flashing System: The Tile Flashing System has six basic components: an aluminum tile base factoryattached to an aluminum pedestal; tile flashing (in Flat, S, or W profile); slotted aluminum plate; aluminum attachment bracket; and cap screw. EcoFasten Solar s published installation instructions provide more detailed dimensional information. 3.2 Description The Tile Flashing System s roof mount component material standards are specified in Table 2 of this report. Tile Flashing System-Flat roof mounts include a painted flat profile aluminum flashing panel nominally 15.51 by 16.97 inch (394 x 431 mm). When installed the Flat flashing has a mounting distance of 4.05 inches (103 mm) from the top of the roof sheathing to the bottom of the support bracket. Figure 1 of this report illustrates the flat roof mounts. Tile Flashing System-S roof mounts include a painted lowprofile barrel-shaped aluminum flashing panel nominally 13.84 by 17.78 inch (351 x 452 mm). When installed the S flashing has a mounting distance of 5.4 inches (137 mm) from the top of the roof sheathing to the bottom of the support bracket. Figure 2 of this report illustrates the S roof mounts. Tile Flashing System-W roof mounts include a painted low-profile barrel-shaped aluminum flashing panel nominally 15.00 by 19.36 inch (381 x 492 mm). When installed the W flashing has a mounting distance of 4.4 inches (112 m) from the top of the roof sheathing to the bottom of the support bracket. Figure 3 of this report illustrates the W roof mounts. Fasteners used to secure the flashing to the wood roof rafter shall be 5 / 16 -inch-diameter (7.9 mm) lag screws complying with ANSI/ASME B18.2.1-B1. The lag screw shall be long enough to penetrate the rafter a minimum of 2 1 / 2 inches (64 mm). Lag screws shall be corrosion-resistant. Table 1 of this report provides allowable pull-out capacities and allowable lateral loads for typical roof lumber. Aluminum attachment brackets are shown in Figure 5 of this report. 4.0 DESIGN AND INSTALLATION 4.1 Design: Compliance to the following shall be provided by the Designer/Engineer if requested by the jurisdiction having authority: The tabulated allowable loads shown in this report are based on allowable stress design (ASD) and include the load duration factor, C D, corresponding with the applicable loads in accordance with ANSI/AWC National Design Specification (NDS). Where the roof mounts are exposed to temperatures exceeding 100 F (37.8 C), uplift allowable loads shall be adjusted by the temperature factor, C t, in accordance with Section 10.3.4 of the NDS temperature factor, C t, which applies to the roof mount connected to supporting wood members where sustained temperatures are greater than 150 F (65.6 C). When products are attached to wood framing having a moisture content greater than 19 percent (16 percent for engineered wood products), or where wet The product described in this Uniform Evaluation Service (UES) Report has been evaluated as an alternative material, design or method of construction in order to satisfy and comply with the intent of the provision of the code, as noted in this report, and for at least equivalence to that prescribed in the code in quality, strength, effectiveness, fire resistance, durability and safely, as applicable, in accordance with IBC Section 104.11. This document shall only be reproduced in its entirety. Copyright 2017 by International Association of Plumbing and Mechanical Officials. All rights reserved. Printed in the United States. Ph: 1-877-4IESRPT Fax: 909.472.4171 web: www.uniform-es.org 4755 East Philadelphia Street, Ontario, California 91761-2816 USA Page 1 of 8

service is expected, the allowable loads shall be adjusted by the wet service factor, C M, specified in Section 10.3.3 of the NDS. Connected wood members shall be analyzed for load-carrying capacity at the connection in accordance with the NDS. 4.2 Installation: The Tile Flashing System shall be installed in accordance with this evaluation report, published manufacture s installation instructions, and the applicable code. Where conflicts occur, the more restrictive shall govern. The Tile Flashing System roof mounts shall be installed using two 5 / 16 inch (7.9 mm) diameter lag screws to connect the preassembled base and pedestal to the rafter. The minimum specific gravity of the wood member shall be 0.42. The Flat, S, or W shaped tile flashing shall be placed over the base-pedestal and fastened to the pedestal using a 5 / 16 inch (7.9 mm) diameter cap screw. Butyl strips shall be applied under lag screw hole locations to provide waterproofing protection.. Installation of the Tile Flashing System roof mounts are limited to roofs having minimum and maximum slopes of 3:12 (14 percent) and 12:12 (45 percent), respectively, as shown in Figure 6. RainBuster adhesive/sealant shall be applied to the leading upslope edge of the tile base and to the predrilled lag holes through the base and backfill hole to provide waterproofing protection. Installation of the Tile Flashing System roof mounts are limited to roofs having minimum and maximum slopes of 3:12 (14 percent) and 12:12 (45 percent), respectively as shown in Figure 7. resistance and connection capacities of fasteners used with the specific proprietary preservative-treated or fireretardant treated lumber. 5.4 Calculations to verify that imposed loads on the assembly do not exceed the allowable loads contained in Table 1 of this report shall be submitted to the code official for approval. 5.5 Calculations for the assembly support framing conforming to IBC Section 1510.2 shall be submitted to the code official for approval. 6.0 SUBSTANTIATING DATA Testing and analysis data submitted is in conformance with IAPMO ES Evaluation Criteria for Joist Hangers and Miscellaneous Connectors, (EC002, approved January 2016). Rain test data is in conformance ICC-ES AC286 and with the Underwriters Laboratory Standard for Gas Vents, (UL 441-10 Section 27). Test results are from laboratories in compliance with ISO/IEC 17025. 7.0 IDENTIFICATION EcoFasten Solar s Tile Flashing System roof mounts are identified with a label bearing the Manufacturers name and address, product designation, IAPMO Uniform ES Marks of Conformity, this evaluation report number (ER-369), compliance code, and inspection agency. 5.0 LIMITATIONS The Tile Flashing System roof mounts described in this report comply with the codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The Tile Flashing System roof mounts shall be installed in accordance with this report, the manufacturer's published installation instructions, and the codes listed in Section 1.1 of this report. Where conflicts occur, the more restrictive shall govern. 5.2 Calculations showing compliance with this report shall be submitted to the code official for approval. The calculations shall be prepared by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed. 5.3 Fasteners used in contact with fire-retardant-treated or preservative-treated lumber shall comply with the 2015 IBC Section 2304.10.5 (2012 and 2009 IBC Section 2304.9.5) or the 2015, 2012 and 2009 IRC Section R317.3, as applicable. The report holder or lumber treater should be contacted for recommendations on minimum corrosion or IAPMO ER #369 Brian Gerber, P.E., S.E. Vice President, Technical Operations Uniform Evaluation Service Richard Beck, PE, CBO, MCP Vice President, Uniform Evaluation Service GP Russ Chaney CEO, The IAPMO Group For additional information about this evaluation report please visit www.uniform-es.org or email at info@uniform-es.org Page 2 of 8

Table 1: Tile Flashing System Allowable Loads (pounds) Specific Gravity Allowable Load at 1/8 Load Direction of Lumber Load Deflection Uplift 0.55 264 42 Uplift 0.42 259 40 Lateral 0.55 556 93 Lateral 0.42 480 81 For SI: 1inch = 25.4 mm Table 2: Material Properties Tile Base 6000 Series Aluminum complying with ASTM B209 Pedestal Tile Flashing -Flat Tile Flashing S 3106 Aluminum (painted) Tile Flashing W Aluminum Brackets: Top Slide: 7.4-inch-long L-shaped slotted connector plate as shown in Figure 4 of this report L-102-3: L-shaped with two slotted holes 6061 T-6 Aluminum complying with ASTM B209 CP-SQ-Slotted: grooved flat plate SCL-101-3: L-shaped with single slot Hex Head Lag Screw 5/16 x 4 or 4.5 long Fasteners: Hex Head Cap Screw 5/16-18 x 1-1/2 long 18.8 SS EPDM bonded metal roof bushing (washer) 5/16 diameter For SI: 1inch = 25.4 mm 18.8 SS, ANSI/ASME B18.2.1-B1 see table 12 QSM for pull out capacities for typical roof lumber (NDS), EPDM rubber and 18.8 SS, Type 304 stainless steel complying with ASTM A 240 Page 3 of 8

EcoFasten Solar Components Figure 1: Tile Flashing System - Flat Figure 2: Tile Flashing System - S Page 4 of 8

Figure 3: Tile Flashing System - W Figure 4: Top Slide Page 5 of 8

SCL-101-3 Bracket L-102-3 Bracket CP-SQ Slotted Figure 5: Brackets Page 6 of 8

Figure 6: Butyl Strips Page 7 of 8

Figure 7: RainBuster Page 8 of 8