Sampler Selection Guide

Similar documents
IPP Sampler Flow Pacing. Presented By Darrell Kuta Teledyne-Isco

Environmental Water Monitoring. Product Guide. Wastewater Process Monitoring

AS950 ALL-WEATHER REFRIGERATED SAMPLER

AS950 REFRIGERATED SAMPLER

Monitoring Considerations and Costs

44 W E & T w w w. w e f. o r g / m a g a z i n e 2007 Water Environment & Technology All rights reserved

Operation and Maintenance of the Teledyne ISCO 6712 Portable Sampler and Water Quality Monitoring Station

SECTION REFRIGERATED AUTOMATIC SAMPLER

Use of Remote Technology in the Surface Water Environmental Monitoring Program at SRS Reducing Measurements in the Field

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Got Nutrients? BAM! Modular Wetland Performance with BAM

MJK Automation YOUR PARTNER FOR WATER PROCESSING INSTRUMENTATION BROCHURE EN 1.00 PRODUCT BROCHURE 1401

Surface Water Sampling

WATER DIVISION INSPECTION REPORT

Updates on EPA Stormwater Program

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

Building a Phase III WIP for Wastewater, Stormwater & Septic Systems

Non-contact UV disinfection systems. Dry Simple Intelligent Energy Efficient

Suck it up Series Effluent Samplers

FITOCLIMA 600 & 1200 BIO

NRF CAPACITANCE LEVEL TRANSMITTER

Inspection Report: Blytheville - West WWTP, AFIN: , Permit #: AR FACILITY TYPE: 1 - Municipal FACILITY EVALUATION RATING:

Bin Management System

1. The facility did not have any maintenance or operation logs for the pump stations.

Sampling. Stationary Portable. Sampling. Sewage Treatment. Municipal Sewerage Systems. Water Protection Control

May 9, Honorable Jean Pace, Mayor City of Mammoth Springs P.O. Box 185 Mammoth Spring, AR Mammoth Springs WWTP (Fulton Co)

MAXX. Mess- und Probenahmetechnik GmbH. Sampling Is Our Passion

Date: 12/07/99. FINAL REPORT Micco E Exfiltration Pipe Project Demonstration Project DEP Contract # WM603. Prepared by:

FITOCLIMA WALK-IN STABILITY

The Case for Operational Optimization

Using the PPM2 Portable Trace Moisture Transmitter

National Pollutant Discharge Elimination System (NPDES) Permit Program F A C T S H E E T

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Model 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas

2. Patrick Manor Pump Station a. 1 pump had no metal guard around the belt drive.

WASTEWATER DISINFECTION

Evaluation of Pollutants in Wastewater Produced from Air Conditioning Cleaning Operations

YOUR EYES IN THE FIELD

IN-THE-PIPE SAMPLER. 1 of S. Indian Hill Boulevard, Claremont, CA

March 9, Ken Fratesi, Manager West Helena Water Utilities 92 Plaza Street West Helena, Arkansas RE: Sanitary Sewer Collection System

Global Water globalw.com

CHAPTER 2 WASTEWATER REGULATORY ISSUES

General Product Presentation

Global Water Instrumentation, Inc.

Bin Management System

Integrated Systems & Services for Stormwater Management

Measuring And Logging The Discharge Behaviour Of Stormwater Overflow Tanks

Quality First! Independent Water Pumping Systems. SDSP Submersible Sump Pump

Personal Organic Purification

APPENDIX C ADEQ CHECKLIST FOR 208 PLAN AMENDMENTS

A REVOLUTION IN PUMPING EFFICIENCY INTRODUCING THE NEW ALL-FLO PUMP. SIMPLE A simple leak free bolted design ensures quick and easy repairs EFFICIENCY

WEF Input to EPA on SSO Rulemaking and Peak Flows

EPA Region 1: NPDES Permitting Background and Update

KAL-K & KAL-A COMPACT THERMAL FLOW SENSOR

1. The facility had several thermometers which had not been calibrated in over a year.

HUBER Sewerage Program

Office of Water. U.S. Environmental Protection Agency

SECTION MOTORS AND PUMPS FOR PLUMBING SYSTEMS

Mini-Plant Malt/Beer/Soda Production Plant LT-PPB-01. Production Process. Learn all the necessary to produce malt/beer/soda and then try your product.

Thermoelectric Generators. Power where you need it.

Isco EZ TOC. TOC and TC Analysis Made Easy. Continuous on-line TOC/TC measurement using low-temperature oxidation

Thermoelectric Generators: How Do They Work?

Technical Seminars. Wastewater Treatment Systems. Rainwater Harvesting Systems & Greywater Systems. Thermal Energy Storage Tanks

Global Water globalw.com

PUMPING SOLUTIONS FOR LANDSCAPE

Incentives to installing a functioning FOG Control Ordinance And Use of an Easy-to-Install Ultrasonic Remote Interceptor Monitoring Device

Global Water Instrumentation, Inc.

Point Source Dischargers Sampling Workshop for the DRBC Stage 2 PCB TMDL. Review of Sampling Protocols

General Specification

Integrated Planning for Meeting Clean Water Act Requirements

FITOCLIMA WALK-IN STABILITY

STORMWATER POLLUTANT ASSESSMENT AT THE CITY OF KISSIMMEE

CITY OF ROCKY RIVER 2010 ANNUAL PROGRESS REPORT

March 1, 2012 Presentation to: Ohio WEA

SUPERSTEAM USG LINE UNFIRED STEAM GENERATOR. Humidification. Sterilization. Pharmaceutical

INDEPENDENT SCHOOL DISTRICT 199 Inver Grove Heights Community Schools th Street East Inver Grove Heights, Minnesota 55076

AP-2A - Threat of or Actual Introduction of a Flammable Substance into the Wastewater System AP Summary:

ForeverPure Power Solar Oasis with Growbox. Complete containerized solar powered desalination system with portable power supply and growbox

Global Water Instrumentation, Inc.

September 23, Mr. Tony Bass Tri-City Utilities Wastewater Treatment Plant P.O. Box 84 Peach Orchard, AR RE: Compliance Inspection

SANITARY SEWER OVERFLOWS AND THE TEXAS COMMISSION ON ENVIRONMENTAL

AIR OPERATED DOUBLE DIAPHRAGM PUMPS

MCAS Cherry Point Implements Innovative Water Quality Monitoring System

Here is a description of the City of Delphos collection system in its entirety and provide

Stormwater Monitoring Challenges and Trip-ups

Q45WQ. Water Quality Monitoring System. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Disposal of chemical waste must be regarded as an integral part of all research projects and teaching programs involving chemical use.

FITOCLIMA 600 & 1200 BIO

Detroit River E. coli TMDL Public Notice Draft

Drought Adaptation Option: Soil moisture monitoring José Payero, Ahmad Khalilian, and Rebecca Davis: Clemson University

Chemical Injection. Systems and Equipment for Oil and Natural Gas

Flow Monitoring Selection Guide. Helping you choose the right solution for your application.

The Infitrak Validated Remote Monitoring Platform

NPDES COMPLIANCE MONITORING STRATEGY AND ANNUAL COMPLIANCE INSPECTION PLAN OCTOBER 1, SEPTEMBER 30, 2018

ZP900 SERIES. High speed, high performance postal scale. 900 SERIES

AQUATIC ACCESS EQUIPMENT

Water Supply and Delivery

Maximizing Sample Recovery on the ACCQPrep HP125

Camden County MUA s. PCB Pollution Minimization Plan

Global Water Instrumentation, Inc.

Transcription:

Sampler Selection Guide 4700 6712FR GLS 3700 6712 Glacier Avalanche

Industria Enforcem I s c o S a m p l e r S u Isco Recommends u 4700 6712FR GL For Use Here Refrigerated Refrigerated Porta Wastewater Treatment Plant * Collection Systems Water Quality Monitoring Advanced Automated Sampler Products From Teledyne Isco With more than four decades of industry leadership, we continue to advance automated water and wastewater sampler technology by developing and producing durable and innovative instruments and software. We offer a wide range of samplers to meet your specific application needs. For in-depth information on Isco sampler products, contact your authorized Isco representative, or visit us on the web at www.isco.com/as. Wastewater Treatment Plants Municipal Wastewater Treatment Industrial Pretreatment Collectio Combin Sanitary

i t a b i l i t y G u i d e S 3700 6712 Glacier Avalanche ble Portable Portable Portable Refrigerated Portable Refrigerated * * * * * Add flow or parameter measurement capability to the sampler with an optional 700 series plug-in module. Use the module data to trigger sample collection and for data analysis. 701 ph/temperature 710 Ultrasonic Flow 720 Submerged Probe Flow 730 Bubbler Flow 750 Area Velocity Flow 780 4-20 ma Analog Input n Systems ed Sewer Overflows (CSOs) Sewer Overflows (SSOs) l Pretreatment Monitoring ent Monitoring Water Quality Monitoring Stormwater Surface Water Resource Water Recreational Water Total Maximum Daily Load (TMDL) Watershed and River Monitoring

Options and Accessories Selection Guide Teledyne Isco offers many options and accessories which allow you to configure the sampler for your specific application. Portable Sampler Power When AC power is present, use Isco power packs to convert AC power to 12 volts DC for the portable sampler. When AC power is not present at the site, select a battery. Standard AC Power Packs Available for 120 and 240 VAC power Battery-backed AC Power Packs For uninterruptible operation in critical applications Nickel Cadmium Batteries 4 amp/hour power for shortterm sampling with easy recharging Lead-acid Batteries 6.5 and 45 amp/hour battery for short- and long-term sampling Solar Panels Extend your remote sampling applications by keeping batteries charged for the next event Charging Stations Designed for optimum charging and maximum discharge/ recharge cycles Bottles When selecting bottles for a sampler, consider the bottle material and configuration. To choose either plastic or glass bottle material, refer to the Code of Federal Regulations 40 CFR 136.3 Table II. This table specifies acceptable containers based on tests to be performed on the collected sample liquid. Governing directives may also specify bottle configurations. Typical bottle configurations include: 1 Composite Bottle Compliance monitoring for NPDES wastewater discharge monitoring 4 Sequential Bottles Compliance monitoring for NPDES stormwater run-off permits 24 Sequential Bottles Process control and enforcement monitoring

Options and Accessories Selection Guide (continued) Suction Line Vinyl Suction Line If using plastic bottles, select vinyl suction line. Vinyl suction line should be replaced as necessary. Black Tygon Suction Line Algae-resistant suction line can be used for general purpose sampling. (Not EPA approved.) PTFE-lined Suction Line If using glass bottles, select PTFE-lined suction line. This chemically inert line can be cleaned and reused often. Strainers Stainless Steel and Polypropylene For most sampling applications using plastic bottles with vinyl suction lines Stainless Steel For use with glass bottles and PTFE-lined suction lines when sampling for metals is not a requirement CPVC Usually selected when sampling for metals PTFE-coated Stainless Steel The choice when other strainer materials are not compatible Low Flow Stainless Steel For depths as low as two inches (5 cm) Ultra-low Flow Stainless Steel For depths as low as one inch (2.5 cm) requires ¼-inch tubing Bottles, suction lines, and strainers contact the sample liquid. Always select wetted materials that are compatible with the sample analysis.

Communications and Data Handling Today s communication, parameter measurement, and software technologies bring many advances and efficiencies to water and wastewater sampling. Contact your Isco representative for more information on: Data communications RS-232, 4-20 ma, SCADA, Modbus, cellular wireless, spread-spectrum radio, and alarm notifications Parameter measurement level, ph, temperature, turbidity, conductivity, and more for sample triggering and data logging Software automate your data analysis and reports Use Flowlink 5.1 software to collect, analyze, and report all of the data from your monitoring program. Special Product Applications Teledyne Isco s Special Product Applications (SPA) team customizes automated sampling equipment to meet the unique needs of our customers around the world. Specialized communications, pressurized sampling, and extended lift heights are only a few of the many solutions they develop. Contact us with your challenging applications. Take a look at Isco s environmental equipment at work www.isco.com/isco-at-work www.isco.com Teledyne Isco, Inc. 4700 Superior Street Lincoln, NE 68504 USA Phone: (402) 464-0231 USA & Canada: (800) 228-4373 Fax: (402) 465-3022 E-mail: iscoinfo@teledyne.com 2010 Teledyne Isco, Inc. Printed in USA L-1148 11/10 Avalanche, Glacier, Flowlink, and Isco are registered trademarks of Teledyne Isco, Inc.