SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant

Similar documents
SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant

SP-100 Equipment Wash SP-110 Tool Cleaner

PRODUCT DATA SHEET SP-3888

3M Scotchkote Liquid Epoxy Coating 323+

Resimac Limited, Unit B, Park Barn Estate, Station Road, Topcliffe, Thirsk, YO7 3SE, North Yorkshire, United Kingdom

3M Scotchkote Abrasion Resistance Epoxy Coating 328

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

PU Anti Graffiti Polyurethane Finish

SIGMAZINC 158. PRODUCT DATA SHEET January 7, 2015 (Revision of December 15, 2014) DESCRIPTION

Prepared By: Engineering Staff Approved By: Jerome T. Schmitz

Solventless, two-component, cross-linked epoxy. Epoxies lose gloss, discolour and eventually chalk in sunlight exposure.

PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

Sea~Barrier is the registered trademark of Altex Coatings Limited

DIMETCOTE 9 / SIGMAZINC 9

Refer to Substrates & Surface Preparation.

Solventless two-component crosslinked epoxy

PPG HI-TEMP PRODUCT DATA SHEET April 16, 2018 (Revision of September 5, 2017) DESCRIPTION

Refer to Substrates & Surface Preparation.

Technical Data Sheet NUKOTE Chemshield TG DESCRIPTION:

SIGMALINE PRODUCT DATA SHEET January 21, 2015 DESCRIPTION. Two-component, solvent-free, amine-cured phenolic epoxy coating

NSP SPECIALTY PRODUCTS Technical Data Sheet. NSP 120 High Performance Epoxy Coating

SIGMAZINC 160. Revision of March 2007 DESCRIPTION. two component moisture curing inorganic zinc (ethyl) silicate primer PRINCIPAL CHARACTERISTICS

3M Scotchkote Liquid Epoxy Coating 323+

SIGMAZINC 158. Revision of September 2008 DESCRIPTION. two component moisture curing zinc (ethyl) silicate primer PRINCIPAL CHARACTERISTICS

PRODUCT SPECIFICATION SHEET BELZONA 5892 FN10193

One-component, heat-resistant silicone acrylic topcoat primarily for the PPG HI-TEMP 1027 primer or the PPG HI-TEMP 222 G primer

PPG HI-TEMP 1000 VS. PRODUCT DATA SHEET December 10, 2014 (Revision of June 30, 2014) DESCRIPTION

APPLICATION GUIDELINE FOR

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

DIMETCOTE 9 H. PRODUCT DATA SHEET May 2, 2018 (Revision of August 7, 2015) DESCRIPTION. Inorganic Zinc Silicate Primer PRINCIPAL CHARACTERISTICS

Application Guide for Internal Flow Efficiency Coating Jotapipe FC 400

Hardener: at least 24 months when stored cool and dry

two component polyamide cured epoxy primer yellow/green - eggshell

Measured in accordance with ASTM D 2697.

Measured in accordance with ASTM D 2697.

(1 g/cm³ = 8.35 lb/us gal; 1 m²/l = 40.7 ft²/us gal) (data for mixed product)

Note: Epoxies will chalk and change color with exterior exposure. Colors are approximately and will tend to change over time.

Application Guide for Internal Flow Efficiency Coating

Aliphatic Acrylic-Polyester Polyurethane

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

AMERLOCK 2 AL. PRODUCT DATA SHEET September 12, 2018 (Revision of May 2, 2018) DESCRIPTION. Fast Dry Aluminum Epoxy Mastic Coating

3,Rothwell Street, Timaru, South Canterbury. ; : Phone or

DIMETCOTE 9 VOC. PRODUCT DATA SHEET July 12, 2016 (Revision of August 7, 2015) DESCRIPTION. Inorganic Zinc Silicate Primer PRINCIPAL CHARACTERISTICS

two component high build amine adduct cured phenolic epoxy primer

APPLICATION GUIDELINE FOR

TL-225-NS Teflon Filled, Vinyl Ester Coating & Lining

ZINGA. Physical data and technical information

SigmaZinc 9 Technical Data Sheet

1.4 kg/l (11.4 lb/us gal) Maximum 295 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) 50 to 63 μm (2.0 to 2.

Carboxane 950 Metallic

FOR COATING TANK INTERIORS

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

two component polyamide cured epoxy primer yellow/green (redbrown on request) - eggshell

PRODUCT SPECIFICATION SHEET BELZONA 5892 FN10106

GULF COAST PAINT MFG., INC

One component, heat-resistant, universal silicone topcoat for use in elevated temperature systems. Replaces HI-TEMP 1000 V / VS / VHA

Sanitile 945 SL PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. 100% solids epoxy

Technical Data Sheet NUKOTE CG DESCRIPTION:

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

PERFORMANCE, 100% SOLIDS,

Refer to Substrates & Surface Preparation.

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Note: Epoxies will characteristically chalk and fade with exposure to sunlight. Light colors are prone to ambering

Hardener: at least 24 months when stored cool and dry

PPG HI-TEMP 1000 V (AMERCOAT 873) PRODUCT DATA SHEET December 10, 2014 (Revision of June 30, 2014) DESCRIPTION

AMERSHIELD VOC. PRODUCT DATA SHEET April 20, 2015 DESCRIPTION. Low VOC Polyester Acrylic Polyurethane PRINCIPAL CHARACTERISTICS

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Zinc Silicate (Inorganic)

Property Test/Standard Description. calculated US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Heresite P-413 TECHNICAL DATA SHEET. P-413 Typical Properties 1 mil DFT) Our 50 years of coating history speaks for itself.

AMERLOCK 2 / SIGMACOVER 2

A two component, 100% solids epoxy based intumescent coating. Aesthetics can be improved by trowel and back rolling.

Bharat Heavy Electricals Limited Piping Centre Chennai-17. Specification Number Revision Number Sheet Number PC:E:GF: of 7 CONTENTS

DURASHIELD 110 &

EPILOX EPOXY BINDER TECHNICAL DATA SHEET. Multi-purpose High Performance Epoxy Binder System DESCRIPTION FEATURES AND BENEFITS

Liquid applied pure polyurea membrane

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1

Innovative Coatings and Linings Technology for Rail Cars. Vijay Datta MS, International Paint LLC and Mike O Donoghue, PhD

NAVSEA REVIEWED ASTM F-718. Interline 783 Finish, Ultra High Solids Two-Pack Fast Cure Solvent-Free Coating

CORLAR 2.1 ST SATIN HIGH SOLIDS EPOXY MASTIC (formerly Corlar 25P )

HEAT-FLEX HI-TEMP 1200 Coating Under Insulation

PPG HI-TEMP 222 G (HEATCOAT 884) PRODUCT DATA SHEET January 19, 2015 DESCRIPTION

Property Test/Standard Description Solids by volume. ISO 3233 Gloss level (60 ) ISO 2813

Product Information CHEMGLAZE B 9942 A/B. Coating for Casting Pits. Easy Application Chemglaze B 9942 A/B will bond to damp and wet surfaces.

Spray applied modified polyurea membrane

TL-280 Sprayable Flake Glass Vinyl Ester Lining System

Ganicin 2.8 ZR-E Zinc-Rich Epoxy Primer

Product Data Barmastic EMH-375

20-30 mils ( microns) per coat mils ( microns) in two or more coats

two component polyamide cured epoxy primer yellow/green (redbrown on request) - eggshell

XM70 Plural-Component Sprayer. High-pressure equipment for protective coatings

Coating Applications - Chemical

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (30 C) calculated VOC-US/Hong Kong

TNEMEC ELEVATED TEMERATURE VINYL ESTER LINING INSTALLATION GUIDE ProPolymer Series 1402, 1422 and 1432 Direct Food Contact FDA Title 21 CFR 175.

A-4300 Clear Silicone Aliphatic Polyurea Technical Data Sheet

POLYURETHANE COATINGS ON STEEL OR DUCTILE IRON PIPE

Technical Data Sheet - PX3350

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

PROTECTO-COAT 900/905

PROTECTO-COAT EPG EPOXY PHENOLIC GLASS FLAKE COATING

Transcription:

DESCRIPTION: SP-9888 Pipe Lining is based on the latest Zero VOC Novolac Technology. The product cures to a highly cross-linked coating with excellent chemical, solvent and water immersion resistance. SP 9888 Pipe Lining can be used as a lining for pipelines containing crude oil, diluted crude, various hydrocarbons, sewage, process water, acids, alkalis, and salt solutions. ADVANTAGES: 100% Solids No VOCs. High abrasion resistance. Excellent chemical, solvent and water resistance. High build, one-coat application. Excellent impact resistance. Good flexibility. Excellent resistance to high temperature cathodic disbonding up to 150 C (302 F) USES: Internal lining for pipelines containing crude oil, diluted crude, various hydrocarbons, sewage, process water, acids, alkalis, and salt solutions. External coating for buried service. For internal lining of tanks please refer to SP-9888 Tank Lining. RELATED MATERIALS: SP-9888 TF Thin Film SP-9888 Tank Lining CLEANING MATERIALS: SP-100 Equipment Wash SP-110 Tool Cleaner SP-120 Internal Storage Lubricant All information, recommendations, and test performance results herein were obtained in a controlled environment and SPC makes no claim that the data and tests accurately represent all environments and specific project specification requirements. As application, environmental and design factors can vary significantly, due care should be exercised in the selection and use of the coating. SPC products are sold with the understanding that the purchaser or user is solely responsible for determining their suitability for any purpose, and that the purchaser or user assumes all risks and liability associated with the use of the product. No guarantee, either expressed or implied, is made with respect thereto or with respect to the infringement of any patent. The information herein is not to be copied, used in Page 1 of 6

SURFACE PREPARATION: Cleanliness : Standards : Near White NACE 2, Sa 2½ (Swedish Scale, ISO 8501-1) SSPC SP-10 (Steel Structures Painting Council) Profile : 62.5 microns minimum to 125 microns maximum (2.5 mils to 5.0 mils) The maximum profile depth on internal pipeline applications shall be reduced to 75 microns (3 mils.). APPLICATION: Spray Grade: Plural Component Spray Equipment XP70 or Graco Hydra-Cat Brush Grade: Brush or Roller MIXING RATIO: By Volume: 3 Parts Base to 1 Part Hardener. HOSE BUNDLE: Heated hose bundle consisting of 3/8 ID base and ¼ ID hardener line with ¼ solvent flush line outside of the bundle. Glycol heat trace or equivalent capable of 80 C (176 F) * Insulated whip hoses not recommended for glycol heat trace* TIP SIZE:.019.031 RECOMMENDED SPRAY PREHEAT TEMPERATURES IN DRUM / PAIL: BASE: HARDENER: 75 C (167 F) to 90 C (194 F) 15 C (59 F) to 30 C (86 F) (typically not heated) Pre-heating of the base material is required to balance the viscosity of base and hardener. In cases of extreme weather conditions the recommended temperatures may change, please consult your SPC representative. Page 2 of 6

RECOMMENDED FILM THICKNESS: 0.508 to 0.875 mm (20 to 35 mils) Internal Pipe Coating. Depends upon application; consult with your SPC Representative. RE-COAT INTERVAL: Base 80 C (176 F) and Hardener 20 C (68 F) Maximum: 6 Hours @ 15 C (59 F) Maximum: 4 Hours @ 25 C (77 F) Re-Coat Interval may vary depending upon the substrate temperature, contact your SPC Rep. Re-coating is best achieved while initial coat is still tacky. Re-blasting of the surface is required of the maximum re-coat interval is exceeded. The minimum re-coat surface preparation interval is 6 hours @ 25 C (77 F). Profile depth shall be the same as previously stated. Small areas 19.35 sq. cm. ( 3 sq. in.) may be sanded using a medium grit (80-100) carborundum cloth. All dust from the sanding or blast roughening must be removed from the surface prior to the application of the coating. HANDLING PROPERTIES: Dry Time @ Base 80 C (176 F) and Hardener 20 C (68 F) (ASTM D1640) [0.75 mm (30 mils) coating thickness @ Substrate Temperature 25 C (77 F)] Touch Dry Time... 2.0 Hours Dry Hard Time... 5.5 Hours Substrate Temperature... The acceptable substrate (metal surface) temperature range for the application of SP-9888 Pipe Lining is 15 C (59 F) to 100 C (212 F). Preheating of the substrate is required if the surface to be coated is below 15 C (59 F). The substrate temperature must be a minimum of 3 C (5 F) above the dew point temperature before proceeding with the coating operation. Internal pipe coating applications can be preheated to 90 C (194 F) Storage / Shelf Life... Store in a cool, dry, well-ventilated area at temperatures between 5 C (41 F) and 40 C (104 F). Keep the container lids sealed when not in use. The Shelf Life is a maximum of 24 months from the date of manufacture if the materials are in unopened containers. Page 3 of 6

LIQUID PROPERTIES: BASE HARDENER Appearance... Tan Liquid. Amber Liquid. Solids Content (%)... 100 100 Specific Gravity (ASTM D1475)... 1.46 ± 0.03 1.05 ± 0.03 Specific Gravity (ASTM D1475)... Base & Hardener Mixed: 1.36 Coverage (Theoretical)... Base & Hardener Mixed: 39.0 m 2 /Litre/25 microns [1604 ft 2 /U.S. Gallon/mil] PHYSICAL / MECHANICAL / ELECTRICAL PROPERTIES: Adhesion to Steel: Dry Adhesion (Pull-off Strength) [MPa (psi)] (ASTM D4541-95-A4) (Self-Alignment Adhesion Tester, Type IV) [25 C (77 F)]... 27 (4000) Wet Adhesion (Hot Water Soak) (CSA-Z245.20-10, Clause 12.14, 28 Days) [Modified to 95 C (203 F)]... Rating #1 Wet Adhesion (Hot Water Soak) (CSA-Z245.20-10, Clause 12.14, 120 Days) [Modified to 75 C ± 3 C (167 F ± 5 F)]... Rating #1 Cathodic Disbonding Test [Average Radius (mm)] (1) (2) (CSA-Z245.20-10, Clause 12.8, System 1A, modified to 28 Days @ 120 C (248 F)]... 6.0 Flexibility ( PPD) (CSA-Z245.20-10, Clause 12.11) [21 C (70 F)]... 1.50 Flexibility ( PPD) (CSA-Z245.20-10, Clause 12.11) [0 C (32 F)]... 1.00 Flexibility ( PPD) (CSA-Z245.20-10, Clause 12.11) [-30 C (-22 F)]... 0.75 Hardness (Shore D) (ASTM D2240-91) [25 C (77 F)]... 84 Impact [Joules (ft-lbf)] (CSA-Z245.20-10, Clause 12.12) [21 C (70 F)]... 5.00 (3.69) Impact [Joules (ft-lbf)] (CSA-Z245.20-10, Clause 12.12) [0 C (32 F)]... 3.50 (2.58) Impact [Joules (ft-lbf)] (CSA-Z245.20-10, Clause 12.12) [-30 C (-22 F)]... 2.50 (1.84) (1) (2) Test modified using an autoclave Test Pressure: 50 psi Page 4 of 6

CHEMICAL RESISTANCE (ASTM G20) (90 days immersion @ ambient temperatures): Ammonium Chloride, 10% solution. Ammonium Hydroxide, 10% solution... Automatic Transmission Fluid... Benzyl Alcohol... Bio Diesel... Brake Fluid... Calcium Chloride, 10% solution... Diesel... Ethanol... Formaldehyde, 37% solution... Gasoline... Hydrocloric Acid, 5% solution... Jet Fuel... Mineral Oil... MEK... Methanol, 50% solution... MIBK... Monoethylene Glycol... Naphtha... Nitric Acid, 5% solution... Potassium Chloride, 10% solution. Sodium Carbonate, 10% solution... Sodium Chloride, 10% solution... Sodium Silicate solution Sodium Hydroxide, 10% solution... Sulphuric Acid, 5% solution... Toluene... Xylene... Zinc Sulphate, 10% solution.. SAFETY: Read the Material Safety Data Sheets before use. EFFECTIVE DATE: October 25, 2016 Rev. 1 Page 5 of 6

CURING TABLE SUBSTRATE TEMPERATURE DRY HARD C F CURING TIME 90 194 3.5 Minutes 80 176 5 Minutes 70 158 8.5 Minutes 60 140 14.5 Minutes 50 122 35 Minutes 40 104 1.75 Hours 30 86 3.5 Hours 20 68 7 Hours 10 50 15.5 Hours Substrate: 12 mm (0.5 in.) Thick Steel Panels Material Temperature: Base: 80 C (176 F) Hardener: 20 C (68 F) Dry Film Thickness: 0.63 mm (25 mils) as per ASTM D1640. Note: The information above is to serve as a guide only. The test results were compiled under laboratory-controlled conditions. Field results may vary due to variable conditions such as radiant heat loss and the cooling effects of wind. Effective Date: August 15, 2014 Page 6 of 6