TECHNICAL SPECIFICATION DANTECO HERMANNS. CONTAINER FOR BULK POWDER Equipped with HERMANNS Aeration and Conveyance Device

Similar documents
TECHNICAL SPECIFICATION FOR 20 x 8 x 8 6 ISO ICC TYPE TANK CONTAINER FOR BULK BITUMEN (UN T3 CODE) PREFACE CONTENTS

T E C H N I C A L S P E C I F I C A T I O N

TECHNICAL SPECIFICATION FOR A TYPICAL STEEL DRY CARGO CONTAINER. 20' x 8' x 8'6" ISO 1CC TYPE GENERAL PURPOSE

6 CONTAINER TECHNICAL SPEC. BULLBOX

TECHNICAL SPECIFICATION FOR. 20' x 8' x 8'6" ISO 1CC TYPE STEEL DRY CARGO CONTAINER WITH

8 CONTAINER TECHNICAL SPEC. BULLBOX

TECHNICAL SPECIFICATION

40 TECHNICAL SPEC. BULLBOX

T E C H N I C A L S P E C I F I C A T I O N

20 OPEN SIDE BOTH SIDES CONTAINER TECHNICAL SPEC. BULLBOX

1.2.2 To satisfy the requirements of Rules of B.V, LR, GL, CCS or A.B.S..

1.0 INTRODUCTION GENERAL SUPPLIER S RESPONSIBILITY CODES AND STANDARDS... 4

Presentation to IMO as mentioned in the ST/SG/AC.10/C.3/2017/40 - (Russian Federation): Fibrereinforced plastics portable tanks

External Reinforcement System

Diffused Aeration Piping Equipment

SECTION 13. A. Extent of Work: The requirements of this section apply to the piping systems specified elsewhere in these specifications.

DANGEROUS GOODS PETRO INDUSTRIAL TANK COMPLIANCE CHECKLIST FORM

80/90/100/120/mm POST Standard Medium Heavy Extra Heavy

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

DEXION RACKING. The Product picture Effect of picture. 80/90/100/120/mm POST. Standard Medium Heavy Extra Heavy

SECTION TAPPING SLEEVES AND VALVES

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

METALS Commissioning of Metals Structural Steel Framing Steel Studs... 2

QUALITY ASSURANCE PROTOCOL (QAP)

Description Unit Quantity Rate Kshs. Amount Kshs.

Code Compliance Research Report CCRR-0238

Meridian Manufacturing Group. Workmanship Meridian Quality Assurance Program

complete with pallet support bars, column guards, safety barriers, pallet back stopper painting

º to 150º F In accordance with this specification and

Stainless Steel Aeration Equipment Specification

SECTION SOUND CONTROL DOORS

SECTION / STC 52 METAL SOUND CONTROL DOORS

(G) DOORS & WINDOWS LIST OF BUREAW OF INDIAN STANDARD CODE OF PRACTICE (ISI)

Code Compliance Research Report CCRR-0238

DETENTION / SECURITY WINDOWS SECTION 08660

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION C1 DUCTILE IRON PIPE AND FITTINGS GENERAL

(Name and address of Manufacturer) (Name and address of Purchaser) (Name and address)

SECTION 1043 FENCE MATERIAL

INVITATION TO BID B I D F O R M. Please submit bid on or before 2:15 pm 101 North Halagueno Street June 6, 2013, at the office of the

Ductile Iron Pipes (Socket & Spigot Pipes)

SECTION GROUND WATER STORAGE TANKS

SECTION METAL ATHLETIC LOCKERS

SPECIFICATIONS - DETAILED PROVISIONS Section Progressing Cavity Pump C O N T E N T S

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

WCU ALUMNI TOWER MASONRY & ENVELOPE REPAIRS

ARCHITECTURAL SPECIFICATIONS

SERIES SA30 STEEL/ALUMINUM FIXED DETENTION WINDOWS SECTION 08651

SECTION DOWNSTREAM DEFENDER

CONSANI ENGINEERING (PTY) LTD

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

SPECIFICATION FOR FIBERGLASS REINFORCED PLASTIC CHEMICAL STORAGE TANKS

SECTION METAL EQUIPMENT LOCKERS

Standard Installation Fire Damper Models: 119, 119(F), 119(SS), D19

SECTION METAL ATHLETIC LOCKERS

FMB15678 Steel Deck Cargo Barge

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

Bucket Elevators and Conveyors Commercial Series Material Handling

Bucket Elevators and Conveyors Commercial Series Material Handling

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

REGIONAL CONSTRUCTION STANDARDS

Section 4. Annex to IAEA Request for Proposal STATEMENT OF WORK. Primary/Secondary cooling water Heat Exchangers

M C I C. MAERSK Container Inspection Criteria. (All Lines) (For use with all DRY Containers in-service) Version 7: 2016

SECTION CHAIN LINK FENCES AND GATES (PARK)

Nylofor Swing Gate. Figure 1: Single Nylofor Swing Gate

M-03 HEAT EXCHANGERS

SAMPLE SPECIFICATIONS FOR PREFABRICATED FRP LIFT STATIONS

INSULATED JOINTS. Monolithic Joints for Electrically Isolating Pipelines

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

CITY OF ODESSA SPECIAL SPECIFICATIONS ITEM 1000 GLASS-FIBER REINFORCED POLYESTER (FRP) REHAB/REPLACEMENT MANHOLE

STANDARD SPECIFICATION FOR

All definitions are defined according to ANSI/AWWA C

GRAIN STORAGE SYSTEMS

1. ARI 410 Standard for chilled water, hot water and steam coils. 2. ARI 430 Central Station Air Handling Units

Materials : Carbon steel or Stainless steel MERXTRADE BV.

AMENDMENTS TO OPSS 408 (OCT 89) CONSTRUCTION SPECIFICATION FOR ADJUSTING OR REBUILDING MANHOLES, CATCH BASINS, DITCH INLETS AND VALVE CHAMBERS

TM Series Induced Draft Cooling Tower Specifications

ONTARIO PROVINCIAL STANDARD SPECIFICATION

HALLOWELL FORT KNOX Modular Utility Storage and Workbench System Specifications

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION DUCTS PART 1 GENERAL 1.01 SUMMARY

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

DRY BULK STORAGE TANK SPECIFICATION PREMIER POWDER COATED BOLTED STEEL TANK

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

All definitions are defined according to ANSI/AWWA C b. Flanged Joint: The flanged and bolted joint as described in ANSI/AWWA C110/A21.10.

7. New railings for existing buildings shall be designed to match any existing railings unless there is a compelling reason for change.

SECTION VIBRATION ISOLATION

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

50948-RHN Putney. Friday, 15 December This document includes: Code Section Revision Dated

Flotation Docking Systems, Inc.

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

BILL OF QUANTITY ENGINEERING & MANAGEMENT CONSULTING CENTRE. "Beit Hanoun Emergency Water Supply Project"

OLYMPIC VIEW WATER AND SEWER DISTRICT APPROVED MATERIALS LIST FOR USE ON NEW CONSTRUCTION OF WATER AND SEWER FACILITIES

UBC Technical Guidelines Section Edition Fume Hoods Page 1 of 5

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

ATI Evaluation Service A Division of Architectural Testing Certification Services

Transcription:

TECHNICAL SPECIFICATION DANTECO HERMANNS CONTAINER FOR BULK POWDER Equipped with HERMANNS Aeration and Conveyance Device 6058(20') x 2438(8') x 2591(8'6") MODEL NO. : CX09-20SNX1 SPEC. NO : CX09-20SNX1-S3 DATE OF ISSUE : May 2017 PREFACE This specification covers design, construction, testing, inspection, function target and performance requirement of model CX09-20SNX1 bulk powder tank containers equipped with HERMANNS Aeration and Conveyance Device manufactured by Danteco Industries BV. The containers specified herein are manufactured under sufficient quality control, which is approved by the authorized classification society: CCS (China Classification Society) 1. Specification and Function target1 Items Unit Parameter External dimension (L x W x H) mm 6,058(20 ) x 2,438(8 ) x 2,591(8 6 ) Internal size of tank L x D mm 6000 x2400 Load Capacity 1 22,500 Tank Volume 1 26,000 Design pressure MPa 0.22 Test pressure MPa 0.33 Design temperature -19 to +80 Max. Gross weight kg 32,000 Tare weight kg 4,200 Loading weight kg 28,000 Air source pressure MPa 0.2~0.3 Air supply m3/min 8 Allowable stacking weight. 1.8g kg 192,000 Manhole diameter mm 500 Air-inlet diameter mm 100mm cam lock type joint Outlet diameter mm 4" male adaptor Design temperature -19 to +80 Average speed of discharge t/min Cement: 1.0 ~1.5 (conveying cement to the silo 25m high, 10m far) Remnant ratio % Cement: 0.1 (Cement: Not more than 1kg) - 2 -

- 2-2. Materials 2.1 Main materials used for the container shall be of the best quality conforming to the requirements of this specification and classification society. 2.2 Materials of the main parts Parts Materials Remark Tank shell Dish end Q345B Yield Point: 33kg/mm2 Bottom side rail Tensile Strength : 52 kg/mm2 Top side rails End rails Structural steel: SS41(Q235) Internals Yield Point: 25 kg/mm2 Walk way Tensile Strength: 41 kg/mm2 Saddles Reinforcement Corner posts SM90A or Q345B Barrel supports Yield Point: 33kg/mm2 End arc support rings Tensile Strength: 50 kg/mm2 Casted Weldable Steel: SCW49 Corner fittings Yield Point: 28 kg/mm2 ISO/R1161 Tensile Strength: 49 kg/mm2 20-GB8163 Pipe Yield Point: 25kg/mm2 Seamless Pipe Tensile Strength: 40 kg/mm2 Valve Cast steel Ventilation layer Synthetic fabric Screws Structural steel: SS400 (Q235) Bolts Yield Point: 25 kg/mm2 Tensile Strength: 41 kg/mm2 3. Construction The bulk powder container is mainly composed of frame, tank and pipe system. The tank is connected to the frames by two-barrel supports and two saddles. 3.1 Tank container frame The container frame shall be composed of front and rear end frames, top and bottom side rails, two (2) barrel supports, two (2) saddle s, eight (8) corner fittings. 3.1.1 Each end frame is constructed by two (2) corner posts, top and bottom end rails, and four (4) thick diagonal corner plates. 3.1.1.1 The corner fittings made of weldable cast steel SCW49 will be designed in accordance with ISO 1161 and manufactured at the works approved by classification society. 3.1.1.2 Each corner post is made of two C shape steel pressings which weld together to form a hollow section with dimension of 174x154xt6.0 by continuous welding. 3.1.1.3 Each top and bottom rail is made of 120 x80 xt5.0 rectangular tubes. 3.1.1.4 Each thick diagonal corner plate is made of a t5.0 mm pressing. 3.1.2 Each bottom side rail is build of "H" type section steel with dimension of 200x100x8x5.5mm. 3.1.3 There are two pieces of top side rails at each side. Both the upper and the lower are made of 80x40xt3.0 rectangular tubes. - 3 -

- 3-3.1.4 Each barrel support is a short cylinder made of 4.0 mm thick high tensile steel. 3.1.4 Two saddles are welded to the bottom of the tank used as the tank auxiliary support and load transfer Each saddle support is build of a base plate, a vertical plate and several ribs. 3.2 Tank body The tank body is a weld structure consisting of one (1) cylindrical shell, two (2) dished ends, and two manholes. The HERMANNS Aeration and Conveyance fluidizing system for the discharge of powder is installed at the bottom of the inside of the tank. 3.2.1 The dia. 2400mm cylindrical shell is of Q345B, t4.5mm thick steel plate. 3.2.2. Each dished end is shaped by hot pressing with Q345 B, t5.0 mm steel plate. 3.2.3 The manhole of dia.500mm shall be composed of a short cylinder, a cover, six (6) swing locking-nuts, a hinge and a gasket. 3.3 Pipe system 3.3.1 The dry compressed airflow via 100 mm cam-lock type joint enters into a main pipe with a 2.5" one-way valve, a 2" safety valve, 1/2"safety valve and a pressure gauge, then goes into two air cavities at each side of the inside of the tank through two branch pipes which separately connected to the tank and main pipe. Another airflow goes through a 1.2" ball valve and a 1.2" one-way valve into the unloading pipe in order to speed up unloading powder. The diameter of main pipe is 76mm and the branch pipe is 57mm. 3.3.2 The unloading pipe is made of 4" steel pipe. One discharge butterfly valve and one 4" male adaptor are fixed on the discharge pipe. 3.3.3 Two 1" ball valves shall be fitted on the top of the tank nearby the manholes. 3.4.4 1.5 side vent pipe from tank top terminated in a ball valve will be provided. 3.4 External fitting 3.4.1 Walkways: Two longitudinal walkways made of steel-net shall be fixed at the each side of the manholes. 3.4.2 Ladder: One ladder is to be fitted at each end of the container and the inside of the tank at the position of the rear manhole. 3.4.3 Customs seal: Customs seal provision must be made on the air inlet, manholes, and unloading outlet in accordance with TIR requirements. 4. Preservation 4.1 Surface treatment All steel parts shall be shot-blasted to Swedish Standard Sa2.5, and immediately spraying 10 to 15 micron thick Zinc-Rich Primer. 4.2 Coating system 4.2.1 After general assembly, all weld seams shall be shot-blasted to Swedish Standard Sa2.5. Any welding slag, spatters and foreign matters shall be removed. 4.2.2 The container has following paint system. Exterior coating system Zinc-rich primer: 30 um Epoxy primer: 40 um Polyurethane top coat: 40 um 110 um(tdft) The inside surface of the tank only coated with 20 to 25 um Zinc-rich primer. - 4 -

- 4-5. Marking 5.1 Materials 5.1.1 Decal:self-adhesive cast plastic, or spraying letter. 5.1.2 Certification plate are made of 0.8m thick, 18-8 stainless steel sheets and treated by chemically etching. 5.2 Regulation 5.2.1 The consolidated plate will be fitted to the regulated location of container end frames with stainless steel blind rivets. Blind rivets and nameplate perimeter are to be caulked with sealant. 5.2.2 The container s serial number and the manufacturer s number of 10mm high shall be separately printed on the side surfaces of left and right corner fittings with steels tamp. 6. Testing and Inspection 6.1 Prototype test A prototype container manufactured in accordance with this specification must be tested according to the procedures described in this specification, and shall be certificated by authorized classification society. Test items Uniformly distributed load Test load Stacking W=(1.8R-T) 86,400 kg / per post Lifting from top corner fittings 2R-T Vertically Lifting from bottom corner 2R-T Lifting forces 45. angle fittings Rigidity (transverse) 15,240 kg Rigidity (longitudinal) 7,620 kg Restraint R-T 32,000 kg / per side Inner inertia longitudinal: R-T transverse: R-T Walk way 300 kg / 600x300mm2 Ladder Pressure test Hydraulic: 0.33 Mpa Pneumatic: 0.242 Mpa Note: R- max. gross weight P-max. Payload T- tare weight 200 kg 6.2 Inspection of production line In mass production, every tank must be carried out 0.33 Mpa. hydraulic pressure test, after the completion of the weld of the container to be carried out 0.242 Mpa pneumatic test, and finally to be carried out 0.2Mpa. Air-leakage inspection. 7. Guarantee 7.1 All the containers shall be guaranteed by manufacturer to be free from defects in materials, workmanship and structure for a period of one (1) year from the date of inspection acceptance. 7.2 The paint system coated on the container surface shall be guaranteed to be free from corrosion and failure for a period of five (5) years from the date of the container by the buyer. During the period of - 5 -

- 5 - guarantee, if paint defect is more than ten (10) percent of the total paint area, the factory and paint supplier will respond for repair cost (all or partial cost). Normal wear and tear and corrosion caused by abrasion, impact, accident, acid, alkali or other chemicals are not covered by this guarantee. The paint supplier s letter of guarantee shall be attached with the contract. 7.3 Guarantee period for self-adhesive cast plastic is (5) years.