ab65313 ADP/ATP Ratio Assay kit (Bioluminescent)

Similar documents
ADP/ATP Ratio Assay Kit (Bioluminescent)

ADP/ATP Ratio Assay Kit (Bioluminescent)

ab Thrombin Inhibitor Screening Assay Kit (Fluorometric)

Cell Viability Assay Kit (Bioluminescent)

ab Plasmin Activity Assay Kit (Fluorometric)

ab Tyrosinase Inhibitor Screening Assay Kit (Colorimetric)

ab MTS Cell Proliferation Assay Kit (Colorimetric)

ab Plasmin Inhibitor Screening Assay Kit (Fluorometric)

ab Factor IXa Activity Assay Kit (Fluorometric)

ab Factor Xa Inhibitor Screening Assay Kit (Fluorometric)

ab Factor VIIIa Activity Assay Kit (Fluorometric)

ab65327 Nitric Oxide Assay Kit (Fluorometric)

ab Adenosylhomocysteinase (AHCY) Inhibitor Screening Assay Kit (Fluorometric)

ab Glutamine Assay Kit (Colorimetric)

ab Glucose Uptake Assay Kit (Cell-based)

ab83371 Alkaline Phosphatase Assay Kit (Fluorometric)

ab65354 Superoxide Dismutase Activity Assay kit (Colorimetric)

ab39412 Caspase 1 Assay Kit (Fluorometric)

ab Thrombin Activity Assay Kit (Fluorometric)

ab Calcium Detection Assay kit (Colorimetric)

ab Mammalian Cell Lysis Buffer 5X Instructions for Use For mammalian cell lysis.

ab Nuclear (Nucleic Acid-Free) Extraction Kit

ab Nuclear Extraction Kit

RayBio ApoSENSOR TM ATP Cell Viability Assay Kit

LDH-Cytotoxicity Assay Kit II

ab Histone Extraction Kit

Ethanol Assay Kit (Colorimetric/Fluorometric) For the rapid, sensitive and accurate measurement of ethanol levels in various samples.

Alanine Transaminase Assay kit (Colorimetric/Fluorometric)

Alanine Transaminase Activity Assay kit (Colorimetric/Fluorometric)

ab65331 L- Lactate Assay kit (Colorimetric)

ab In vitro Angiogenesis Assay Kit

ab DNA-Protein Binding Assay Kit (Fluorometric)

ab Glucose Oxidase Activity Assay Kit (Colorimetric)

ab DNA-Protein Binding Assay Kit (Colorimetric)

ab Beta Galactosidase Detection Kit (Fluorometric) Instructions for Use For monitoring β-galactosidase activity in cells.

ab Plant Chromatin Extraction Kit

ab IL10 (Interleukin-10) Canine ELISA Kit

ab MBL (Mannose-Binding Lectin) Human ELISA Kit

ab Complex IV Rodent Enzyme Activity Microplate Assay Kit

ab FAP Human ELISA Kit

ab Fura-2 No Wash Calcium Assay Kit

For the rapid, sensitive and accurate measurement of Caspase 3 Activity in cell and tissue lysates.

ab Enterokinase cleavage kit

ab Glutamate Assay Kit (Fluorometric)

ab Immunoprecipitation kit

ab Cysteine Assay Kit (Fluorometric)

ab Histone H4 Acetylation Assay Kit

ab Luminescent ATP Detection Assay Kit

ab Collagenase Activity Assay Kit (Colorimetric)

For the sensitive and accurate measurement of adenylate cyclase activity in cell extracts, tissue extracts and biological fluids.

ab Nitric Oxide Synthase Inhibitor Screening Kit (Fluorometric)

ab83355 ATP Assay Kit (Colorimetric/ Fluorometric)

ab Histone H3 Acetylation Assay Kit

ab CD163 (M130) Human ELISA Kit

For the rapid, sensitive and accurate measurement of apoptosis in various samples.

ab Cyclooxygenase 2 (COX2) Inhibitor Screening Kit (Fluorometric)

ab Fast Bisulfite Conversion Kit

ab ATPase Assay Kit (Colorimetric)

Enhanced Apoptotic DNA Ladder Detection Kit

Total NAD and NADH Assay Kit (Colorimetric)

ab Complex I Enzyme Activity Microplate Assay Kit (Colorimetric)

ab R-Phycoerythrin Conjugation Kit Protocol

ab TIMP2 Human ELISA Kit

For the rapid, sensitive and accurate measurement of Tyrosine in biological samples.

For the rapid, sensitive and accurate measurement of Histone Acetyltransferase activity in cell and tissue lysates.

ab Histone H3 Total Acetylation Detection Fast Kit (Colorimetric)

Protein Quantitation Kit (Bradford Assay)

For the rapid, sensitive and accurate measurement of Glutamate in various samples.

ab Histone H2B Acetyl (K5) ELISA Kit

ab Biotin (Type A) Fast Conjugation Kit

ab NAD/NADH Assay Kit (Fluorometric)

ab Histone H3 Total Quanification Kit (Colorimetric)

ab Histone Methyltransferase H3 (K9) Activity Quantification Assay Kit

Cell Viability Assay Kit Fluorometric Near InfraRed

ab IL-1 Beta (Interleukin-1 Beta) Rat ELISA Kit

Rhod-4 No Wash Calcium Assay Kit

ab MTT Cell Proliferation Assay Kit

Aspartate Aminotransferase Activity Assay Kit (Fluorometric)

pan-caspase (Active) Red Staining Kit

ab Bacterial Assay (Luminescent)

ab Biotin (Type A) Fast Conjugation Kit

ab Biotin (Type B) Fast Conjugation Kit

ab Histone Acetyltransferase Inhibitor Screening

Fluo-8 No Wash Calcium Assay Kit

ab Cellulase Activity Assay Kit (Fluorometric)

Fluo-8 Medium Removal Calcium Assay Kit

ab Streptavidin Conjugation Kit Protocol

ab Total Sulphite Assay Kit (Colorimetric)

ab65354 Superoxide Dismutase Activity Assay kit (Colorimetric)

ab Apoptosis/Necrosis Detection Kit (blue, red, green)

ab Leptin Rat ELISA Kit

ab Nitric Oxide Assay Kit (Flow cytometry -

ab Dylight 488 Fast Conjugation Kit

ab ERK1/2 (Thr202/Tyr204) In-Cell ELISA Kit

ab Methylated DNA Quantification Kit (Colorimetric)

ab Cy3 Fast Conjugation Kit

Nitric Oxide Assay Kit (Fluorometric)

ab Histone H3 (tri-methyl K27) Quantification Kit (Fluorometric)

ab DNA Isolation and Bisulfite Conversion Kit

Transcription:

ab65313 ADP/ATP Ratio Assay kit (Bioluminescent) Instructions for Use For the rapid, sensitive and accurate measurement of the ratio of ADP/ATP in various samples. This product is for research use only and is not intended for diagnostic use. Version 7b Last Updated 2 October 2017

Table of Contents INTRODUCTION 1. BACKGROUND 2 2. ASSAY SUMMARY 3 GENERAL INFORMATION 3. PRECAUTIONS 4 4. STORAGE AND STABILITY 4 5. MATERIALS SUPPLIED 5 6. MATERIALS REQUIRED, NOT SUPPLIED 5 7. LIMITATIONS 6 8. TECHNICAL HINTS 7 ASSAY PREPARATION 9. REAGENT PREPARATION 8 10. SAMPLE PREPARATION 9 ASSAY PROCEDURE and DETECTION 11. ASSAY PROCEDURE and DETECTION 11 DATA ANALYSIS 12. CALCULATIONS 13 13. TYPICAL DATA 14 RESOURCES 14. QUICK ASSAY PROCEDURE 15 15. INTERFERENCES 16 16. TROUBLESHOOTING 17 17. FAQs 19 18. NOTES 22 Discover more at www.abcam.com 1

INTRODUCTION 10.BACKGROUND ADP/ATP Ratio Assay Kit (Bioluminescent) (ab65313) is based on the bioluminescent detection of the ADP and ATP levels in the sample for a rapid screening of apoptosis, necrosis, growth arrest, and cell proliferation simultaneously in mammalian cells. In this assay, luciferase catalyzes the conversion of ATP and luciferin to light, which subsequently can be measured using a luminometer or Beta Counter. ADP level is measured by its conversion to ATP that is subsequently detected using the same reaction. The assay can be fully automatic for high throughput and is highly sensitive (detects 100 mammalian cells/well). ATP + D-Luciferin + O 2 Luciferase oxyluciferin + AMP + PPi + CO 2 + light The changes in ADP/ATP ratio have been used to differentiate the different modes of cell death and viability. Increased levels of ATP and decreased levels of ADP have been recognized in proliferating cells. In contrast, decreased levels of ATP and increased levels of ADP are recognized in apoptotic cells. The decrease in ATP and increase in ADP are much more pronounced in necrosis than apoptosis. Discover more at www.abcam.com 2

INTRODUCTION 11.ASSAY SUMMARY Induce apoptosis in cells Prepare reaction mix and add to wells Transfer cells to wells Read luminescence Add ADP converting enzyme Read luminescence Discover more at www.abcam.com 3

GENERAL INFORMATION 12.PRECAUTIONS Please read these instructions carefully prior to beginning the assay. All kit components have been formulated and quality control tested to function successfully as a kit. Modifications to the kit components or procedures may result in loss of performance. 13.STORAGE AND STABILITY Store kit at -20ºC in the dark immediately upon receipt. Kit has a storage time of 1 year from receipt, providing components have not been reconstituted. Refer to list of materials supplied for storage conditions of individual components. Observe the storage conditions for individual prepared components in section 5. Aliquot components in working volumes before storing at the recommended temperature. Reconstituted components are stable for 2 months. Discover more at www.abcam.com 4

GENERAL INFORMATION 14.MATERIALS SUPPLIED Item Amount Storage Condition (Before Preparation) Storage Condition (After Preparation) Nucleotide Releasing Buffer 50 ml -20 C -20 C ATP Monitoring Enzyme 1 vial -20 C +4 C ADP Converting Enzyme 1 vial -20 C +4 C Enzyme Reconstitution Buffer 2.15 ml -20 C -20 C 15.MATERIALS REQUIRED, NOT SUPPLIED These materials are not included in the kit, but will be required to successfully utilize this assay: MilliQ water or other type of double distilled water (ddh 2 O) Luminometer 96 well plate white walled luminometer plate Microcentrifuge Pipettes and pipette tips Heat block or water bath Vortex Dounce homogenizer or pestle (if using tissue) Discover more at www.abcam.com 5

GENERAL INFORMATION 16.LIMITATIONS Assay kit intended for research use only. Not for use in diagnostic procedures. Do not use kit or components if it has exceeded the expiration date on the kit labels. Do not mix or substitute reagents or materials from other kit lots or vendors. Kits are QC tested as a set of components and performance cannot be guaranteed if utilized separately or substituted. Discover more at www.abcam.com 6

GENERAL INFORMATION 17.TECHNICAL HINTS This kit is sold based on number of tests. A test simply refers to a single assay well. The number of wells that contain sample, control or standard will vary by product. Review the protocol completely to confirm this kit meets your requirements. Please contact our Technical Support staff with any questions. Keep enzymes and heat labile components and samples on ice during the assay. Make sure all buffers and developing solutions are at room temperature before starting the experiment. Avoid cross contamination of samples or reagents by changing tips between sample and reagent additions. Avoid foaming or bubbles when mixing or reconstituting components. Samples generating values higher than the highest standard should be further diluted in the appropriate sample dilution buffers. Ensure plates are properly sealed or covered during incubation steps. Make sure you have the appropriate type of plate for the detection method of choice. Make sure the heat block/water bath and microplate reader are switched on before starting the experiment. Discover more at www.abcam.com 7

ASSAY PREPARATION 18.REAGENT PREPARATION Briefly centrifuge small vials at low speed prior to opening. 9.1 Enzyme Reconstitution Buffer: Ready to use as supplied. Equilibrate to room temperature before use. Store at -20 C. 9.2 Nucleotide Releasing Buffer: Ready to use as supplied. Equilibrate to room temperature before use. Store at -20 C. 9.3 10x ADP Converting Enzyme: Reconstitute ADP Converting Enzyme with 220 µl of Nucleotide Releasing Buffer and mix gently by inversion. Store at +4 C. Keep on ice while in use, protected from light as much as possible. 9.4 ATP Monitoring Enzyme: Reconstitute ATP Monitoring Enzyme with 2.1 ml of Enzyme Reconstitution Buffer and mix gently by inversion. Store at +4 C. Keep on ice while in use, protected from light as much as possible. Discover more at www.abcam.com 8

ASSAY PRE ASSAY PREPARATION 19.SAMPLE PREPARATION General Sample information: We recommend that you use fresh samples. If you cannot perform the assay at the same time, we suggest that you complete the Sample Preparation step before storing the samples. Alternatively, if that is not possible, we suggest that you snap freeze cells or tissue in liquid nitrogen upon extraction and store the samples immediately at -80 C. When you are ready to test your samples, thaw them on ice. Be aware however that this might affect the stability of your samples and the readings can be lower than expected. We recommend setting up the samples in culture plates and not culture bottles to allow easy transfer to assay plate. Induce apoptosis in cells by desired method. Concurrently incubate a control culture without induction. 10.1 Suspension cell samples: 10.1.1 Harvest the amount of cells (untreated and treated with the desired apoptosis inducer) necessary for each assay (initial recommendation = 1 x 10 4 1 x 10 6 cells). Ensure that the density of your sample is 10 3 10 4 cells/10 µl culture. 10.2 Adherent cell samples: 10.2.1 Grow cells and incubate with desired apoptosis inducer (include a control culture without treatment). 10.2.2 Remove culture medium from plate. 10.2.3 Add Nucleotide Releasing Buffer (50 µl Buffer per 10 3 10 4 cells) and incubate for 5 minutes at room temperature with gentle shaking. NOTE: Nucleotide Releasing Buffer helps gently loosen the membrane so that ATP will leak out the cell without complete cell lysis. Discover more at www.abcam.com 9

ASSAY PRE ASSAY PREPARATION 10.3 Tissue samples: 10.3.1 Harvest the amount of tissue necessary for each assay (initial recommendation = 10 mg). 10.3.2 Wash tissue in cold PBS. 10.3.3 Prepare a single cell suspension by any method that does not disrupt membrane integrity (cells have to stay intact). 10.3.4 Add Nucleotide Releasing Buffer (50 µl Buffer per 10 3 10 4 cells) and incubate for 5 minutes at room temperature with gentle shaking. NOTE: Nucleotide Releasing Buffer helps gently loosen the membrane so that ATP will leak out the cell without complete cell lysis. NOTE: Avoid contamination with ATP from exogeneous biological sources e.g. bacteria or fingerprints. Discover more at www.abcam.com 10

ASSAY PROCEDURE and DETECTION 20.ASSAY PROCEDURE and DETECTION Equilibrate all materials and prepared reagents to room temperature prior to use. It is recommended to assay all controls and samples in duplicate. 11.1 Reaction Mix: Prepare Reaction Mix for each reaction: Component Reaction Mix Samples (µl) ATP Monitoring Enzyme 10 µl Nucleotide Releasing Buffer 90 µl Mix enough reagents for the number of assays (samples, standards and background control) to be performed. Prepare a Master Mix of the Reaction Mix to ensure consistency. We recommend the following calculation: X µl component x (Number samples + standards +1) 11.2 Add 100 µl of the Reaction Mix to control and sample wells and read the background luminescence (Data A). NOTE: For higher accuracy let the reaction sit at room temperature to burn off low level ATP contamination for a few hours. 11.3 Cell Sample Set up: a) For suspension cells: Transfer 10 µl of the cultured cells (10 3 10 4 cells) into luminometer plate. b) For adherent and tissue cells: Transfer 50 µl of cells (10 3 10 4 cells) treated with Nucleotide Releasing Buffer into luminometer plate. - After approximately 2 minutes read the sample in a luminometer or luminescence capable plate reader (Data B). - Dilute 10x ADP-Converting enzyme 10-fold with Nucleotide Releasing Buffer. To measure ADP levels in the cells, read the samples (step12.4) again (Data C), then add 10 µl of 1x ADP Converting Enzyme. Discover more at www.abcam.com 11

ASSAY PRE ASSAY PROCEDURE and DETECTION - Read the samples again after approximately 2 minutes (Data D). NOTE: The results can be analyzed using cuvette-based luminometers or Beta Counters. When Beta Counter is used it should be programmed in the out of coincidence (or Luminescence mode) for measurement. The entire assay can directly be done in a 96-well plate*. It can also be programmed automatically using instrumentation with injectors (When using injector the ATP Monitoring Enzyme and the ADP Converting Enzyme can be diluted with the Nuclear Releasing Buffer at 1:50 for injector). *The assay utilizes a glow-type luciferase which has replaced the original flash-type luciferase. While still sensitive to subpicomole amounts of ATP, the glow-type reactions can still be read an hour later. This means that ATP & ADP levels are now determined by quasi-steady-state light output levels. This makes the reading of an entire 96-well (384-well) plate much more feasible. Discover more at www.abcam.com 12

DATA ANALYSIS 21.CALCULATIONS Samples producing signals greater than that of the highest standard should be further diluted in appropriate buffer and reanalyzed, then multiplying the concentration found by the appropriate dilution factor. For statistical reasons, we recommend each sample should be assayed with a minimum of two replicates (duplicates). ADP/ATP ratio = [Data D Data C] / [Data B Data A] Where: Data D = sample signal~2 min after addition of 10 µl 1X ADP Converting Enzyme to cells. Data C = sample signal prior addition of 1X ADP Converting Enzyme to cells. Data B = sample signal ~2 min after addition of cells to reaction mix Data A = background signal of reaction mix Discover more at www.abcam.com 13

ASSAY PRE DATA ANALYSIS 22.TYPICAL DATA Interpretation of results: Cell Fate ADP Level ATP Level ADP/ATP ratio Proliferation Very low High Very low Growth Arrest Low Slightly increased Low Apoptosis High Low High Necrosis Much higher Very low Much higher The interpretation of different ratios obtained may vary significantly according to the cell types and conditions used. However, the following criteria may be used as guidelines: Proliferation = Test shows markedly elevated ATP values with no significant increase in ADP levels in comparison to control cells. Growth arrest = Test shows similar or slightly higher levels of ATP and little or no change in ADP compared to control cells. Apoptosis = Test shows lower levels of ATP to control but shows an increase in ADP. Necrosis = Test shows considerable lower ATP levels than control but greatly increased ADP. When ADP/ATP ratio increases, cells are going through apoptosis or necrosis but when the ratio decreases, the cells could be in growth arrest or still proliferating. Discover more at www.abcam.com 14

RESOURCES 23.QUICK ASSAY PROCEDURE NOTE: This procedure is provided as a quick reference for experienced users. Follow the detailed procedure when initially performing the assay. Prepare enzyme mix; get equipment ready. Prepare samples in duplicate. Prepare Reaction Mix (Number samples + 1). Component Reaction Mix Samples (µl) ATP Monitoring Enzyme 10 µl Nucleotide Releasing Buffer 90 µl Add 100 µl of the reaction mix to the background wells and read the background luminescence (Data A). For suspension cells, transfer 10 µl of the cultured cells per well. For adherent cells: add 50 µl treated cells per well. Read after ~2 min (Data B). To measure ADP levels in the cells, read the samples again (Data C). Add 10 µl of 1x ADP Converting Enzyme. Read the after ~ 2 minutes (Data D). Discover more at www.abcam.com 15

RESOURCES 24.INTERFERENCES Discover more at www.abcam.com 16

RESOURCES 25.TROUBLESHOOTING Problem Cause Solution Assay not working Sample with erratic readings Lower/ Higher readings in samples and Standards Use of ice-cold buffer Plate read at incorrect wavelength Use of a different 96- well plate Samples not deproteinized (if indicated on protocol) Cells/tissue samples not homogenized completely Samples used after multiple free/ thaw cycles Use of old or inappropriately stored samples Presence of interfering substance in the sample Improperly thawed components Allowing reagents to sit for extended times on ice Incorrect incubation times or temperatures Buffers must be at room temperature Check the wavelength and filter settings of instrument Colorimetric: Clear plates Fluorometric: black wells/clear bottom plate Use PCA precipitation protocol for deproteinization Use Dounce homogenizer, increase number of strokes Aliquot and freeze samples if needed to use multiple times Use fresh samples or store at - 80 C (after snap freeze in liquid nitrogen) till use Check protocol for interfering substances; deproteinize samples Thaw all components completely and mix gently before use Always thaw and prepare fresh reaction mix before use Verify correct incubation times and temperatures in protocol Discover more at www.abcam.com 17

RESOURCES Problem Cause Solution Standard readings do not follow a linear pattern Unanticipated results Pipetting errors in standard or reaction mix Air bubbles formed in well Standard stock is at incorrect concentration Measured at incorrect wavelength Samples contain interfering substances Sample readings above/ below the linear range Avoid pipetting small volumes (< 5 µl) and prepare a master mix whenever possible Pipette gently against the wall of the tubes Always refer to dilutions on protocol Check equipment and filter setting Troubleshoot if it interferes with the kit Concentrate/ Dilute sample so it is within the linear range Discover more at www.abcam.com 18

RESOURCES 26. FAQs Why didn't my ATP Monitoring Enzyme completely dissolve? The ATP monitor enzyme is hard to dissolve and the final solution is a yellow-green milky solution (not clear solution). This is normal and it is fine to use it. What kind of Luciferase is used in this assay? The Luciferase used was expressed in E. coli using the cloned luciferase gene from the North American firefly, Photinus pyralis. It rapidly loses activity after reconstitution. It should either be used fresh or deep freeze immediately after reconstitution. Why is our 10 minute reading higher than the 1 minute reading? The fact that the 10 min value is higher than the 1 min value means that when the lysate settled down, it become clearer for light passing through and thus results in higher readings. We suggest 2 options to try (1) centrifuge the samples to collect and use only the clear portion of the cell lysate. (2), using more cells (e.g., 10 000 cells/assay) may obtain more reliable results. Does any wavelength limit need to be set while detecting this assay with a luminometer? No, unlike fluorometric readings where the emission has a specific wave length for reading the excited molecule, and the excitation has an optimum wave length to excite the molecule, the chemiluminescence works on a different principal. The molecule is present at a high energy level. The substrate breaks that constriction and brings it down to the lower and more stable energy level. The difference in energy is released in the form of light. The luminometer captures this light and measures its intensity. There is no wave length setting in this process. Discover more at www.abcam.com 19

RESOURCES Could you confirm if this kit has ever been used with a Beckman Coulter LS6500 Multipurpose Scintillation Counter? Do you have any advice on how we can set up the instrument to use with this kit? Would this type of reader be suitable? The read out of this kit is via luminescence and hence if the indicated equipment is a luminometer, the equipment can be used. Theoretically a luminometer and a scintillation counter are different. Conventional scintillation counters can t be used. However, when Beta Counter is used it should be programmed in the out of coincidence (or Luminescence mode) for measurement. So if the equipment has this setting which can be programmed, then the beta counter may be used. We have detected have levels of ATP and ADP. If we want to present the ATP levels independent of the ratio, which concentration unit or how can we convert the levels to concentration? To get the exact concentration, you would need a standard which is not included in this kit. You can purchase an ATP standard, but you will have to optimize the production of the standard curve. The protocol suggested that we need to add 50 µl Nucleotide Releasing Buffer to 10 3-10 4 adherent cells, how we can change the volume of buffer when we have 1x10 6 Beas-2B cells? We would recommend you to take just 10 4 cells for this assay. If the cell number cannot be taken, we would recommend using ~5 ml of the buffer to keep up the proportion. Discover more at www.abcam.com 20

RESOURCES Why do I need to measure the level of ADP/ATP so many times? The Data B is for the ATP generated by the cells when they are incubated with the NRB. Data C is for the total ATP released and present in the sample which keeps rising for a few minutes after the cells are incubated with the NRB and finally plateau off. Before the ADP converter is added you will not know the levels of ADP, since only ATP will be recognized luminometrically. The ADP has to be converted to ATP for recognition. Data D is after conversion of ADP from the samples to ATP. Discover more at www.abcam.com 21

RESOURCES 27. NOTES Discover more at www.abcam.com 22

UK, EU and ROW Email: technical@abcam.com Tel: +44-(0)1223-696000 Austria Email: wissenschaftlicherdienst@abcam.com Tel: 019-288-259 France Email: supportscientifique@abcam.com Tel: 01-46-94-62-96 Germany Email: wissenschaftlicherdienst@abcam.com Tel: 030-896-779-154 Spain Email: soportecientifico@abcam.com Tel: 911-146-554 Switzerland Email: technical@abcam.com Tel (Deutsch): 0435-016-424 Tel (Français): 0615-000-530 US and Latin America Email: us.technical@abcam.com Tel: 888-77-ABCAM (22226) Canada Email: ca.technical@abcam.com Tel: 877-749-8807 China and Asia Pacific Email: hk.technical@abcam.com Tel: 108008523689 ( 中國聯通 ) Japan Email: technical@abcam.co.jp Tel: +81-(0)3-6231-0940 www.abcam.com www.abcam.cn www.abcam.co.jp Copyright 2017 Abcam, All Rights Reserved. The Abcam logo is a registered trademark. All information / detail is correct at time of going to print. RESOURCES 23