DENR Public Water Supply Section FIGURE 1(A): ALKALINITY VS PH

Similar documents
DIVISION 2: BACKFLOW PREVENTION PROGRAM

DIVISION 5. BACKFLOW PREVENTION AND CROSS-CONNECTION CONTROL

Town of Chocowinity Backflow and Cross Connection Ordinance

130 CROSS CONNECTION CONTROL

SECTION CROSS CONNECTION CONTROL TABLE OF CONTENTS

CROSS-CONNECTION CONTROL/BACKFLOW PREVENTION

WATER DEPARTMENT STANDARD SPECIFCATIONS SECTION 301 CROSS CONNECTION POLICY

CHAPTER 6 SECTION 6.19 AN ORDINANCE OF THE TOWN OF MAYODAN TO PROTECT THE QUALITY OF THE PUBLIC POTABLE WATER SUPPLY

CROSS-CONNECTION CONTROL PROGRAM HARVEST-MONROVIA WATER, SEWER AND FIRE PROTECTION AUTHORITY

The following words and terms, when used in this article, shall have the following definitions, unless the context clearly indicates otherwise:

ORDINANCE NO. 519 AN ORDINANCE ADOPTING THE RULES AND REGULATIONS RELATING TO WATER SUPPLY CROSS-CONNECTIONS AND REPEALING ORDINANCE NO. 459.

MODEL ORDINANCE FOR CROSS CONNECTION CONTROL BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF, STATE OF WYOMING:

Water Supply System. Plumbing and Cross Connection Control. Cross-Connection. Connection. Plumbing Overview 9/24/

8.04 Protection Requirements

DALTON UTILITIES CROSS CONNECTION CONTROL RULES AND REGULATIONS. Enacted By THE WATER, LIGHT & SINKING FUND COMMISSION OF DALTON, GEORGIA

CROSS-CONNECTION CONTROL PROGRAM

Premises Isolation Cross-Connection Control Program

The rules and regulations, as part of this document, shall apply to all premises serviced by the public water system of the Northeast Water System.

BACKFLOW PREVENTION ASSEMBLY INSTALLATION STANDARDS

ARTICLE VI. The Town of Trappe Cross Connection and Backflow Prevention Program is contained in

CITY OF HAMILTON Codified Ordinance CHAPTER 941

CROSS CONNECTION CONTROL PROGRAM POLICY Adopted March, 1990 Revised October, 2006

ORD-3182 BE IT ORDAINED BY THE COUNCIL OF THE CITY OF VIRGINIA BEACH, VIRGINIA:

QUONSET DEVELOPMENT CORPORATION QUONSET & LADD WATER SYSTEMS CROSS CONNECTION CONTROL & BACKFLOW PREVENTION POLICY

DUPLIN COUNTY BACKFLOW PREVENTION ORDINANCE This ordinance shall be known as the Duplin County Backflow Prevention Ordinance.

Ordinances of the Plainview Water District Town of Oyster Bay, Nassau County, New York ARTICLE VII CONTROL OF BACKFLOW AND CROSS-CONNECTIONS

PORTLAND WATER DISTRICT CROSS-CONNECTION CONTROL PROGRAM 1989 REVISED MAY, 2006 REVISED SEPTEMBER, 2009 REVISED JUNE, 2017

RURAL WATER DISTRICT

CHAPTER 53: BACKFLOW PREVENTION AND CROSS CONNECTION CONTROL

C R O S S - C O N N E C T I O N C O N T R O L

DIVISION 3. CROSS CONNECTION CONTROL* Sec Definitions.

For further. information. contact your. local water. purveyor or the PNWS/AWWA. Cross-Connection. Control Committee. through the.

SECTION XIV: BACKFLOW PREVENTION AND CROSS-CONNECTION CONTROL Backflow Prevention & Cross-Connection Control Program Purpose

Premises having a repeated history of cross-connections being established or reestablished.

Public Utilities Department Backflow/Cross Connection Informational Meeting February 24, 2004

Cross-Connection Control Policy

GRAYWATER SYSTEMS FOR RESIDENTIAL BUILDINGS

Amendments to the 2006 International Plumbing Code

ORDINANCE NO Chapter 203B of the Glencoe Municipal Code is established to read in its entirety as follows:

Water Service 39 BACKFLOW PROTECTION

CROSS CONNECTION CONTROL PROGRAM

READ ONLY. Adopting Agency BSC SFM. Adopt Entire Chapter Adopt Entire Chapter as amended (amended sections listed below)

December Illinois American Water Cross Connection Control Program

101 S. George St 116 E Gas Ave York, PA York, PA (717) (717)

Policy Number: 6030 Cross-Connection & Backflow Prevention 1. GENERAL 2. PURPOSE 3. AUTHORITY 4. DEFINITIONS

2012 International Plumbing Code. Exhibit D

Read Only Copy Not For Distribution. Chapter 17. Private Potable Water Supply Systems 17.1 GENERAL REGULATIONS 17.2 QUANTITY OF WATER REQUIRED

ARTICLE VI. CROSS-CONNECTION/BACKFLOW PROTECTION

PROVIDENCE WATER SUPPLY BOARD CROSS-CONNECTION CONTROL PROGRAM RULES AND REGULATIONS

TITLE 64 LEGISLATIVE RULE BUREAU FOR PUBLIC HEALTH SERIES 15 CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION. use.

CROSS - CONNECTION CONTROL PROGRAM BELFAST WATER DISTRICT

Cross-Connection Control Program and Plan of Operation

Policy Number: 6030 Cross-Connection & Backflow Prevention 1. GENERAL 2. PURPOSE 3. AUTHORITY 4. DEFINITIONS

Chapter 25 PLUMBING*

GRAY WATER SYSTEMS FOR RESIDENTIAL BUILDINGS

SUPPLEMENTAL 2011 PLUMBING CORRECTION SHEET FOR HIGH-RISES

1 Exam Prep Florida Building Code- Plumbing, 2014 Tabs and Highlights

WATER & SEWER SERVICES

Copyright 2017, ProVent Systems Inc., All Rights Reserved

Cross-Connection Control Program. Manual of Procedures

THE CONSOLIDATED MUTUAL WATER COMPANY CROSS CONNECTION CONTROL PROGRAM GENERALLY

Amendments to the 2012 International Plumbing Code

2015 UPC Chapter 6 Water Systems Part 1 RV

Cross-Connection Control Program

FRWA SAMPLE ORDINANCE

Cross-Connection Control and Backflow Prevention Program

CROSS-CONNECTION CONTROL PROGRAM OLD TOWN WATER DISTRICT OLD TOWN, MAINE

KING COUNTY WATER DISTRICT NO. 125 KING COUNTY, WASHINGTON. RESOLUTION NO. ~ S D * \k: - dj (j

; WATERMAINS SPECIFICATIONS FOR CROSS CONNECTIONS and BACKFLOW PREVENTION SECTION C5.0

ARTICLE IV CROSS CONNECTION CONTROL AND BACKFLOW PREVENTION

ORDINANCE NO. 124 SECTION 1 - GENERAL POLICY. 1.0 PURPOSE- The purpose of this ordinance is:

Cross-Connection Control Program

ARKANSAS PLUMBING C ODE. Based on the 2006 International Plumbing Code

CROSS-CONNECTION CONTROL AND BACKFLOW PREVENTION PROGRAM THE ISLAND WATER ASSOCIATION, INC. SANIBEL, FLORIDA

BACKFLOW - SELF ASSESSED SURVEY TO BE COMPLETED BY PROPERTY OWNERS

qwertyuiopasdfghjklzxcvbnmqwertyui opasdfghjklzxcvbnmqwertyuiopasdfgh jklzxcvbnmqwertyuiopasdfghjklzxcvb nmqwertyuiopasdfghjklzxcvbnmqwer

APPENDIX A INSTALLATION CRITERIA FOR REDUCED PRESSURE PRINCIPLE AND DOUBLE CHECK VALVE BACKFLOW PREVENTION ASSEMBLIES

GRAY WATER RECYCLING SYSTEMS

City of Hollywood, Florida Department of Public Utilities Cross-Connection Control Plan

RULES AND REGULATIONS FOR WATER AND WASTEWATER SERVICE APPENDIX G BACKFLOW PREVENTION AND CROSS CONNECTION CONTROL (BPCCC) PROGRAM

SOQUEL CREEK WATER DISTRICT BACKFLOW PREVENTION AND CROSS-CONNECTION CONTROL POLICY AND PROCEDURES Adopted by Board of Directors on 9/01/15 PURPOSE

Cross Connection Control & Backflow Assembly Testing

Table of Contents Rules Concerning Uniform Plumbing Code

Utility Service Application

TABLE OF CONTENTS PART III MINIMUM DESIGN STANDARDS Section 115 WATER DISTRIBUTION SYSTEM GENERAL SIZING LINES 115.

ALDERWOOD WATER & WASTEWATER DISTRICT SNOHOMISH COUNTY, WASHINGTON RESOLUTION NO

HOLLEY NAVARRE WATER SYSTEM, INC. BACKFLOW PREVENTION & CROSS CONNECTION CONTROL POLICIES & REGULATIONS

GRAYWATER STANDARD PLAN For Simple Residential System

City of Weiser Cross Connection ordinance 1217

2017 BUILDING PERMIT FEES

LAKE CRYSTAL MUNICIPAL UTILITIES CROSS CONNECTION AND BACKFLOW PREVENTION POLICY

(Contaminant) Backsiphonage or Backpressure Backsiphonage or Backpressure

Cross-Connection Control Manual

POLICY GOVERNING CROSS CONNECTIONS, AUXILARY INTAKES, BYPASSES, AND INTERCONNECTIONS

TITLE 17. (b) Auxiliary Water Supply is any water supply other than that received from a public water system.

Chapter DRAFT - PLUMBING CODE* (Current working draft of Juneau Building Code Advisory Committee 10/24/ unadopted)

Part 14 Cross Connection Rules Isolation of a high hazard use Obstacles to approaching this type of facility Types of equipment in these types of

2010 California Green Building Standards Code: Nation s First Mandatory Statewide Standards Code to Green Construction and Fight Climate Change

CROSS CONNECTION CONTROL ORDINANCE

THE CONSOLIDATED MUTUAL WATER COMPANY CROSS CONNECTION CONTROL PROGRAM GENERALLY

Transcription:

FIGURE 1(A): ALKALINITY VS PH FIGURE 1(B): ALKALINITY VS TOTAL FREE CARBON DIOXIDE Source of Figures 1(a) and 1(b): Water Supply and Waste Disposal. Hardenberg, W.A., and Rodie, E.S., International Textbook Co., Scranton, PA 1961. - 319 -

FIGURE 2: NORTH CAROLINA GUIDELINES CROSS CONNECTION CONTROL IN WATER DISTRIBUTION SYSTEMS These guidelines are supplemental to Section.0406(b). These guidelines are intended as a minimum requirement. Public water suppliers may adopt more stringent requirements. Each supplier of water shall conform to the minimum requirements established in these guidelines. I. Degree of Hazard: A. Severe: Actual or potential threat of contamination that presents an imminent danger to the public health with consequence of serious illness or death. B. Moderate: One that presents foreseeable and significant potential for pollution, nuisance, aesthetically objectionable or other undesirable alterations of the drinking water supply. II. Backflow Prevention Assembly Requirements: Degree of hazard RPZ* DCVA** Air Gap Severe X ------- X Moderate ------- X ------- * Reduced pressure zone ** Double check valve assembly *** This is not intended to be an exhaustive list (This printed version is corrected from the July 2010 version which erroneously listed all irrigation as high hazard.) III. Facilities that Require Installation of a Backflow Preventer***: A. Moderate hazard - DCVA: 1. Fire sprinkler systems without booster pump facilities or chemical additives. 2. Connection to tanks, lines and vessels that handle non-toxic substances. 3. Lawn sprinkler systems without chemical injection or booster pumps. 4. Most commercial establishments. 5. Automatic service stations, bakeries and beauty shops with no health hazard and bottling plants with no back pressure. 6. etc. B. Severe hazard - RPZ or air gap: 1. Lawn sprinkler systems with chemical injection or booster pumps 2. Wastewater treatment plants 3. Connection to an unapproved water system or unapproved auxiliary water supply 4. Connection to tanks, pumps, lines, steam boilers or vessels that handle sewage, lethal substances, toxic or radioactive substances 5. Fire sprinkler systems with booster pump facilities or chemical additives 6. Buildings with five or more stories above ground level 7. Hospitals and other medical facilities 8. Morgues, mortuaries and autopsy facilities 9. Metal plating facilities 10. Bottling plants (subject to back pressure) 11. Canneries 12. Battery manufacturers 13. Exterminators and lawn care companies - 320 -

14. Chemical processing plants 15. Dairies 16. Film laboratories 17. Car wash facilities 18. Dye works 19. Laundries 20. Swimming pools 21. Water front facilities 22. etc. IV. Approved Backflow Prevention Assemblies: Meets American Society of Sanitary Engineering (ASSE) standard and carries ASSE seal or is on the University of Southern California approval list. V. Backflow Prevention Assembly Installation: Backflow prevention assemblies must be located in a place where it is readily accessible for regular testing, maintenance and inspection. Bypass lines parallel to a backflow prevention assembly shall have an approved backflow prevention assembly installed that is equal to that on the main line. A. RPZ: 1. Above ground installation preferred. 2. Below ground vault shall have positive drainage with adequate gravity drainage to atmosphere. 3. 12 inches minimum clearance from vault walls and floor. 4. Installation in accordance with manufacturer's recommendations. B. DCVA: 1. Vertical or horizontal installation acceptable. 2. Adequate drainage shall be provided if installed below ground. - 321 -

FIGURE 3(A): DEMAND WEIGHT OF FIXTURES IN FIXTURE UNIT Fixture type Weight in fixture units Bathtub 4 Bedpan washer 10 Bedit 4 Demtal unit or cuspidor 1 Dental laboratory 2 Drinking fountain 2 Kitchen sink 4 Lavoratory 2 Laundry tray (1 or 2 compartments) 4 Shower, each head 4 Sink: service 4 Urinal, pedastal 10 Urinal (wall lip) 5 Urinal stall 5 Urinal with flush tank 3 Urinal trough (for every 2 foot section) 2 Wash sink, circular or multiple (each set of faucets) 2 Water closet: F.V. 10 Water closet: tank 5 FIGURE 3(B): EXAMPLE FIXTURE UNITS AND ESTIMATED DEMANDS Kind of Fixtures No. of Fixtures Building Supply Fixture Units Demand (gallons per minute) Water closets 130 1,300 Urinals 30 150 Shower heads 12 48 Lavoratories 130 260 Service sinks 27 81 TOTAL 1,839 310-322 -

FIGURE 3(C): ESTIMATE CURVES FOR DEMAND LOAD 500 450 400 350 Demand - GPM. 300 250 200 150 100 50 1 2 No. 1 for system predominately for flush valves No. 2 for system predominately for flush tanks 0 0 500 1000 1500 2000 2500 3000 Fixture Units FIGURE 3(D): ENLARGED SCALE DEMAND LOAD 120 Demand - GPM 100 80 60 40 20 0 0 20 40 60 80 100 120 140 160 180 200 220 240 Fixture Units - 323 -

FIGURE 4: TYPICAL WELL HEAD DETAILS LEGEND 1. Control box 2. Blow off line 3. Gate valve 4. Check valve 5. dresser coupling (or union) 6. Meter 7. Pressure gauge (w/needle valve) 8. Sample faucet (non-threaded) 9. Screened vent 10. Sanitary well seal 11. Electrical conduit 12. Electrical cable seal 13. Electrical lighting NOTES A. Leave clearance between wall and valve for turning valve B. Slope ground surface away from slab C. Grout around casing to impervious stratum (50 min. depth) D. Slope floor to drain E. Provide hatch in roof above well casing. NOTE* Grout the annular space between the casing and the surrounding soil to a distance of at least twenty (20) feet below ground surface.. - 324 -

FIGURE 5: PRESSURE & VOLUME DIFFERENTIALS FOR HYDROPNEUMATIC TANKS 180 170 160 150 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 70 60 100 90 50 40 30 20 10 0 PRESSURE IN TANK IN POUNDS FOR SQUARE INCH - GUAGE 80 VOLUME OF WATER IN TANK IN PERCENT OF TOTAL VOLUME - 325 -

FIGURE 6: VOLUME OF HYDROPNEUMATIC TANKS The following examples are offered in further explanation of the requirements for proper sizing of hydropneumatic tanks. As previously indicated, it is required to supply the indicated peak demand for a period of twenty minutes, and it is assumed that a combination of hydropneumatic storage and pumping will be utilized. The Effective Volume of the tank is considered to be the volume of water discharged between the high and low pressure setting. Required Effective Volume = (Peak Demand Pumping Capacity) x 20 minutes For example, a mobile home system to serve 50 spaces and having a pumping capacity of 30 gpm would require an effective volume of: Req d. Effective Volume = (Peak Demand Pumping Capacity) x 20 minutes = (60-30) x 20 = 600 gallons (For peak demands, see Rule.0802) The actual tank size required to furnish the 600 gallons effective volume depends upon the pressure settings, air-water volume controls, etc. A system without controls would require the largest tank, whereas a system with air charging device and automatic air-water volume controls would require a much smaller tank. The curves indicating air-water volume relationships shown in Figure 5 may be utilized to determine required tank sizes. Continuing the above example, assume further that it is necessary to operate the tank on a 60-40 psi pressure cycle, and assume that the tank has no air-water volume controls and was not precharged. These conditions are indicated by the top curve in Figure 5 since this curve passes through the 0% water 100% air point. At 60 psi, water volume: 80% At 40 psi, water volume: 73% Therefore, the percent water volume discharges during the 60-40 psi cycle is 80-73%=7% of the total tank volume. The total volume of a tank necessary to produce the required effective volume of 600 gallons: 600 Total Volume = = 8570 gallons 0.07 The tank size can also be determined by direct calculation rather than by using Figure 5. By using the principle of Boyle s Law and assuming the effects of temperature to be negligible, the tank is sized accordingly. Continuing the above example and converting the pressure to Absolute (gauge + 14.7 psi), the volume is calculated as follows: If there is no water (100% air) in the tank originally and it is filled with water until a pressure of 60 psi gauge is reached, the volume of air at that point is: P 1 V 1 = P 2 V 2 P 1 V 1 (0 + 14.7 psi) x (100) Vol. 2 = = 19.7% (air) P 2 (60 + 14.7 psi) On a 60-40 psi cycle, the tank would discharge to a pressure of 40 psi, and the air volume would be: P 2 V 2 (60 + 14.7 psi) x (19.7%) Vol. 3 = = 26.9% (air) P 3 (40 + 14.7 psi) The percent volume of water discharged during the 60-40 cycle is: - 326 -

Percent volume: 26.9 19.7 = 7.2% The total tank volume necessary to produce the required effective volume of 600 gallons is: 600 gal. Total Volume = = 8330 gallons 0.072 By utilizing an air charging system with automatic air-water volume controls, it is possible to discharge up to 25% of the tank volume during a 60-40 psi pressure cycle. The total tank volume necessary to furnish the required effective volume in this case would be: Total Tank Volume = Required Effective Volume (gallons) 0.25-327 -