Products Solutions Services. Density Profile Measurement in the Oil and Gas Industry Increase the economic efficiency in separation processes

Similar documents
Products Solutions Services. Radiometric measurement technology A safe principle that meets the highest demands

Technical Information Gamma Radiation Source FSG60, 137 Cs and FSG61, 60 Co

What ensures measurement to accurate standards?

On-Line Diagnostics Techniques in the Oil, Gas, and Chemical Industry

Radiometric Measurement Gamma Radiation Sources

Gamma Radiation Source FSG60, 137 Cs and FSG61, 60 Co

Measuring Bulk Solids on a Conveyor

Solutions for the Oil & Gas Industry

SECTION Inline ULTRASONIC FLOW METERS

PanaFlow Z3 Ultrasonic liquid flow meter. Ultrasonics 3. bhge.com

SECTION Coriolis Mass Flow Meters

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Prosonic Flow B 200. For reliable flow measurement of biogas without limitations

Ultrasonic clamp-on technology Flow measurement from outside the pipe. Cost-effective flexible robust

BMA-System#3 Technical Application Sheet

Rosemount 3051S Series of Instrumentation Scalable Pressure, Flow, and Level Solutions

Our Cyprus strategic alliance associates presentation TAPROGGE

Technical Information Memosens CPS31D and Ceratex CPS31

Proline Promag 400 For flow measurement of water and wastewater

SITRANS FCS200 & SIFLOW FC070 set new standards for excellence in integration. The flowmeter solution for saving time, cost and space.

Thermal Mass Flow Meters Help Reduce Energy Costs and Enhance Emissions Monitoring Systems

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

SECTION ULTRASONIC BIOGAS FLOW MEASURING SYSTEM

UPU Inline Delamination Detection with the Ultrasonic Measuring System. Fire Protection. Measuring Technology. Service

CALDON LEFM Ultrasonic Flowmeters for Gas Applications. Integrating experience, proven technology, and innovation

L-DENS 7000 DENSITY SENSOR SERIES

Mitigate Your Corrosion Risks Predictive Corrosion Management

Best practices for flow calibration management

Technical Information Turbimax CUS52D

Data sheet HYGROPHIL H 4230 process hygrometer

Manufacturing Range. Production and Know-how Center RÜEGER SA, Crissier (Switzerland)

JUMO flowtrans DP P. Pitot tube P01 to P04. Applications. Brief description. Special features. Customer benefits

DEVELOPMENT OF RADIOMETRIC METHODS FOR OPTIMIZATION OF PHOSPHATE TRANSPORT PROCESS BY ''SLURRY PIPE''

3M CATHODE TRACKING SOLUTION. Tracking System for Permanent Cathodes and Anodes in Metal Refining Plants

KLARO grease separator KL sepa.pop

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

SECTION CORIOLIS MASS FLOW MEASURING SYSTEM

The Unique Accelabar Flow Meter

Technologies, Solutions, and Applications

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

VERIS Accelabar. Superior Flow Measurement Accuracy

Rosemount 405 Compact Orifice Primary Element

Radiometric Measuring Source Container QG 020/100

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flowrates

WEIGHING SYSTEMS FOR BULK MATERIALS

NEW CONTROL SYSTEM DETECTS DESALTER PROBLEMS BEFORE UPSETS OCCUR Gary Fransen Agar Corporation Prepared for presentation at The AICHE 2004 Spring

Turbine Meter. P e

Dense Medium Controller Specification (F revision 1.2)

Accutube Averaging Pitot Tubes

Best Practices for Flow Calibration Management

REAL-TIME PUMP CONDITION MONITORING

SIWAREX FTC The belt scales in SIMATIC More than just standard. siwarex ftc

SensEvolution Shelt Product Line Cabinets and shelters

SITRANS F X SITRANS F. Answers for industry. Vortex flowmeter The optimum measurement device for steam, gases and liquids

ON-LINE OIL TRACE MONITOR

News. Power Generation 11. ph Control Reduces Acid Consumption in Neutralization Process up to 90 % Perspectives in Pure Water Analytics THORNTON

Flow Test Data Book and Flow Handbook for 405 Compact Orifice Series and 1595 Conditioning Orifice Plate

PanaFlow MV82. Insertion Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

G2S. Vertical Sump Pump

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max

Competence in turbidity, solids and sludge level measurement

Mitigate Your Corrosion Risks Predictive Corrosion Management

High-Precision Engine Indicating Onboard and on the Test Bench

Treat oily waste with decanter centrifuge plants

Rosemount Annubar Flowmeter Series. The Value of Innovation, Realized

GVSO chemical submersible pump: The safe pumping solution for high-pressure and high-temperature applications

Solar Flat Plate Thermal Collector

EuroFID Total Hydrocarbon Analyzer

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

Swirl flowmeter FS4000 Compact, reliable and robust

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

WYATT Orifice flow PrOducTs

Memosens CPS76D. Technical Information

RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits

Continuous Level Sensor CONDURIX 31.1

COMBIMASS Thermal Gas Flow

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

Chemical Industry Solutions

M-PHASE Magnetic resonance multiphase flowmeter for the simultaneous measurement of oil, gas and water

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

PRODUCT OVERVIEW 2 ABOUT MICROWAVE PRECISION INSTRUMENTS, INC

Whatever you need to measure: level, pressure, flow, temperature or liquid analysis, we have the instrument to do the job. And all under one roof!

Proline Promass 100 / Promag 100 The flow specialists in a compact design

OXITEC O 2. InSitu analyser systems DEVELOPED AND MANUFACTURED IN GERMANY

News. Pulp & Paper. Turbidity Measurement Improves Efficiency of Green Liquor Filtration. Perspectives in Liquid Process Analytics

Laird Thermal Systems Application Note. X-ray Cooling in Industrial Scanners

Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water

forming the on-line analysis and started conducting it in the laboratory.

Crude Oil Pretreatment (Preparation of Crude Oil for Distillation): (Degassing-Dehydration & Desalting)

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany

SBX 1000 In Situ Oxygen Transmitter

Reference thermometer Model CTP5000

Micro Motion Technical Overview and Specification Summary

Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise

World Top Class FCX-A

AutoCal. Calibration made Simple. 3/2013 page : 1

Utilizing NDT for Cost Effective Maintenance and Mitigation Purposes

Products Solutions Services. Endress+Hauser. Engineering in Food & Beverage

Transcription:

Products Solutions Services Density Profile Measurement in the Oil and Gas Industry Increase the economic efficiency in separation processes

2 Density profile measurement

Density profile measurement 3 Density and level measurement in oil and gas processes Reliability, safety and accuracy The applications and production processes of the oil and gas industry require the highest degree of reliability, safety and efficiency. Operators need detailed production information to control their processes effectively and to increase product quality. The radiometric instrumentation of Endress+Hauser provides a high degree of reliability and accuracy in this respect. For more than fifty years, we have supplied our instruments and solutions to all large-scale producing industries and have extensive know-how, particularly in oil & gas as well as petrochemical applications. We thus contribute to designing the production processes of our customers more economically efficient. Our product innovations and developments essentially contribute to safer and more economically efficient applications and increase plant availability. Separation processes in refineries or on production platforms constitute tremendous challenges for the availability and economically effective utilization of a plant. Downstream processes and the added value of the entire production depend on the efficient use of upstream separation processes. This requires an accurate and reliable measuring method. Ideally, users should be well aware of what is happening in the separation tank to enable them to use this information for direct action on the quality of the medium to be produced. This is exactly what we are offering with the radiometric measuring principle. Interface and density profile measurement In interface monitoring, Endress+Hauser density and interface measurement offers the optimum solution for complete monitoring of interface and emulsion layers of different densities in separation tanks. Radiometric instrumentation and, in particular, the solution using a Density Profile Measuring System (DPS) offer operators the possibility of getting a view of what is happening in their process by a safe as well as non-invasive and thus process-independent measuring method. The density profile computer (Profile Vision) visualizes the measuring results simple and clear so that the results can be quickly implemented in further process optimizing and user control. Advantages Density Profile Measuring System (DPS) Optimized and precise process information by continuous density profile measurement and high resolution across the entire measuring range Information concerning the density and position of interfaces in one measuring operation Complete measuring system of instruments, hardware, software and visualizing Easy HMI integration in the higher-ranking process control Non-invasive, maintenance-free measuring method Easy, space-saving installation of the source container No mechanically moved parts The radiometric instrumentation of Endress+Hauser guarantees the highest degree of safety with different certifications, e.g. SIL and ATEX.

4 Density profile measurement Interface measurement The measuring principle is based on the fact that the radiation emitted by the radioactive isotope (source) is attenuated as it penetrates material and the medium to be measured. In radiometric interface measurement, the source is inserted into a closed immersion pipe via a rope extension thus preventing any contact between the source and the medium. Interface measurement arrangement Depending on the measuring range and the application, one or several detectors, also called compact transmitters, are assembled on the outside of the tank. The compact transmitter calculates the average density of the medium between source and detector from the radiation received. A direct correlation to the interface may be derived from this density value. Density profile measurement To obtain detailed information on the distribution of layers of different densities in a tank, a density profile is measured using a multi-detector solution. Several compact transmitters are installed next to each other on the outside of the tank wall. The measuring range is divided into zones. Each compact transmitter measures the density in its respective zone and a density profile is derived from these values. Density profile measurement arrangement Gas Crude oil With the Density Profile Measuring System (DPS), Endress+Hauser provides a unique solution for the high-resolution measurement of the distribution of layers in separators. Both the continuous operation and maintenance work, for example removal of sand from the tank, can be performed much more efficiently and economically using the Profile Vision design and arrangement. Water

Density profile measurement 5 Several measuring systems are individually arranged next to each other to measure the entire separation process within a tank. The respective density profile measurement system is located in the corresponding critical process sections. Separator Crude oil Additive Gas The first measurement is taken close to the inlet in order to recognize any sand build-up immediately. To monitor the separation process and the thickness of the emulsion layer, another measurement is taken in the center of the tank. Measuring in front of the weir facilitates optimum control of the flow of oil over the weir. This 3D profile is the most detailed type of density profile measurement in any separation process. Sand Water Oil Density profile measurement with 3 sections Water Oil

6 Density profile measurement System design In its density profile measurement, Endress+Hauser offers a complete system of four harmonized components. Components of the density profile measuring system Radioactive source FSG60/61 Radioactive isotope with double steel encapsulation complies with the highest classification of sources. Detector FMG60 The device is composed of a sensor unit and an electronic unit to analyze and transmit the measured values. Source container FQG63 The FQG63 source container serves as a transport and storage container for radioactive sources. Density profile calculator Profile Vision Complete system design of density profile measurement Operator Profile Vision Source container Gas Crude oil Compact transmitter Sand Water Oil

Density profile measurement 7 Mechanical design Source container and immersion pipe The ideal position of the source in the tank is determined. The radioactive source does not come in contact with the medium in the tank. The source is inserted from the source container into the immersion pipe using a rope extension. The source container is mounted with either a DIN or ANSI flange adapter on the process flange. This ensures that the source container can be readily removed from the process tank and reinstalled without having to interrupt the process. A centering flange is included and permits easy installation and commissioning of the source container. Detectors The detectors (compact transmitters) are installed on the outside of the tank thus avoiding any contact with the process medium. Easy access to the instruments is ensured at any time irrespective of the process. Since the detectors are located directly on the tank, the installation is space-saving and easily accessible. Installation, maintenance and a possible exchange of detectors can be realized during actual operation. There are no mechanically moving parts since the measurement is performed in a stationary and permanent manner within the tank. Reliable and repeatable results are achieved after the first calibration facilitating a diversified perception of the processes within the tank. Source container with a bent and straight immersion pipe Assembly of detectors directly on the tank Source container Centering flange Flange adapter Assembly of detectors using an assembly frame Process flange Immersion pipe, bent Immersion pipe, straight Rope extension

8 Density profile measurement Profile calculator and measuring design Profile Vision the profile calculator for the density profile measuring system generates data to visualize the measurement. Threshold values to define the density values are determined in the system. On basis of these values, the interface or emulsion layers are identified. The values may be adapted due to changes of the general setting (e.g. pressure or temperature) at any time. Users can thus react flexibly to changing ambient impacts without having to recalibrate the system. Profile Vision requires an external power supply and a separate line for the interface to the main control system (SPS, DCS). The data from the density profile calculator is transferred to the control system via any interface. The power supply of the detectors may be arranged via a main line to the separator. From there, the detectors are connected to the supply via an individual fuse. The detectors communicate with the density calculator via Profibus, HART or FOUNDATION fieldbus. A status message of a device is received by the density calculator and transferred to the control system. In addition, there is the possibility of writing parameters into the density calculator from the control system. This is an advantage if, for example, the quality of the mixture of oil and water fed into the tank changes and parameters have to be adapted in the visualizing system. Measuring design Profile Vision Detectors AC DC Distribution box supply and fuse Distribution box communication

Density profile measurement 9 Application examples Separator, Free Water Knock Out Drum (FWKO) treater The goal of a separation process is to separate the extracted mixture into its ingredients of sand, sludge, water and oil. Separator Additive The density profile measurement by Profile Vision permits an essentially more detailed view of the position of respective layers. The position of the emulsion layer provides information on the process. Additives may also be more efficiently controlled by a direct view of the progression of the process in the tank. This contributes considerable to cost saving. Optimizing the separation makes it possible to increase the supply of fresh mixture and thus to raise the productivity of the process. Crude oil Gas The improved quality allows downstream processes on a platform or at a refinery to operate in an optimum fashion thus contributing to an improved flow rate, increasing the quality of the final products and raising the economic efficiency of the entire production process. Sand Water Oil Advantages Density Profile Measurement in separation processes Reduction of water and salt in the separating and refinery process Optimized use of chemicals due to an efficient separation process Online measurement improves quality control (or alternatively: Effective quality control of the production process) Level and density profile information in real time Arrangement of detectors for the profiler system on the tank.

10 Density profile measurement Desalting Crude oil is desalted at the refinery to prevent corrosion. In this process, water is added to generate an emulsion of crude oil and water. The emulsion is again separated in an electrostatic desalter in which the saline water sinks to the bottom and the desalted oil is pumped to the distillation process. Since the desalter uses electrostatic plates, monitoring of the process is of paramount importance because an excessive level could endanger the mode of operation of the process equipment. Desalter Oil Salty Water Salty Water Advantages Density profile measurement in desalting processes Reliable reduction of salt in the process Reduction of plant downtimes and maintenance costs due to improved capacity utilization Salt build-up can be prevented in good time by exact measurements and process control Optimized use of chemicals due to an efficient desalting process

Density profile measurement 11 Economic efficiency of density profile measurements Tank desanding In regular continuous operation, sand deposits have to be removed from a separation tank twice a month. During cleaning, the tank is not available for production thus reducing the output of the entire plant. In each maintenance interval, average costs of US$ 24,000 are incurred which add up to more than US$ 1 million during an operating period of 24 months. DPS-optimized operation reduces the maintenance work so that tank cleaning is merely required once a month. The one-time acquisition costs of DPS are already amortized after approx. 6 months. Additives Additives attain a faster separation of water and oil. DPS facilitates a more effective process which considerably reduces these additives. Our installations in oil production permit our customers savings of additives in the desalting process of US$ 1000 per day on average. The investment in one Profile Vision unit is thus already amortized after approx. 6 months. Cost development tank desanding Cost development additives $ 1.200.000 Costs $ 1.200.000 Costs $ 1.000.000 $ 1.000.000 $ 800.000 $ 800.000 $ 600.000 $ 600.000 $ 400.000 $ 400.000 $ 200.000 $ 200.000 $ 0 1 With DPS Without DPS 5 9 13 17 21 Months $ 0 1 With DPS Without DPS 5 9 13 17 21 Months Cost savings Cost savings

www.addresses.endress.com CP01205F/00/EN/01.16