LAMINATED VENEER LUMBER

Similar documents
OUR COMPANY OUR WARRANTY OUR GUARANTEE

GLOBAL LVL HEADERS, BEAMS AND COLUMNS. 1.9E-2850Fb. 1.9E-2850Fb. User guide User guide. lvlglobal.com

BROADSPAN. LVL Design Brochure. Design properties for LVL header and beam applications in the U.S. for residential floor and roof systems

1¾" VERSA-LAM WESTERN HEAdER GuidE

Technical Data for. Headers. and Beams

2.2E Parallam PSL Deep Beam

LPI 56 Technical Guide

2.2E Parallam PSL Deep Beam

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

KERTO HEADER INSULATED LVL HEADER 31/2", 51/2" 3 1/2" AND 5 1/2" THICKNESSES DESIGN VALUES USA

2.2E Parallam PSL Deep Beam

Joint Evaluation Report

Joint Evaluation Report

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

Joint Evaluation Report

U.S. WALL GUIDE. Featuring Trus Joist TimberStrand LSL and Parallam PSL Wall Framing. Engineered to meet code requirements for walls up to 30' tall

CH. 9 WOOD CONSTRUCTION

Featuring Trus Joist TimberStrand LSL and Parallam PSL Wall Framing

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

LVL Product Guide 2.0E LVL 1.5E LVL

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

Open-Web Trusses. Including Red-L, Red-W, Red-S, Red-M and Red-H Trusses. Design Flexibility. Outstanding Strength-to-Weight Performance

Stora Enso S-LVL Laminated Veneer Lumber (LVL) TER No

Warranty Certificate. Allied Structural Materials, LLC. Our Warranty. warrants

Murphy Laminated Veneer Lumber Murphy Engineered Wood Division Revised January 24, 2017

VERSA-LAM 2.0E SPECIFIER GUIDE EASTERN CANADA. Work. Build. Create. 3rd Edition Canada

BROADSPAN. I-Joist Design Brochure. Design properties for I-joist applications in the U.S. for residential floor systems. I-Joist Design Brochure

ADVANCED FRAMING LUMBER

Ready-to-Frame Solutions for the Fire Protection of Floors. LP SolidStart LSL and LP FlameBlock I-Joists. U.S. Technical Guide U.S.

Building Division Informational Handout

Murphy Laminated Veneer Lumber Murphy Engineered Wood Division Revised May 30, 2013

Connect Easily to Insulated Concrete Forms

Connect Easily to Insulated Concrete Forms

Including RedForm LVL, RedForm-I65, I90 and I90H Joists. Lightweight for Fast Installation. Compatible with Standard Framing

SECTION PLATE CONNECTED WOOD TRUSSES

Lamco Laminated Finger Jointed Lumber (LFL ) TER No

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: LOUISIANA PACIFIC CORPORATION

ESR-1190 Reissued December 1, 2013 This report is subject to renewal December 1, 2014.

Determining Allowable Design Values for Wood

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

INSTALLATION. US Version. Includes AJS 140 / 150 / 20 / 190 / 25 and VERSA-LAM BEAMS. Lifetime Guaranteed Quality and Performance

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

I-Joist and LVL Installation Guide

Fundamentals of Wood Design and Engineering

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels ( )

Featuring Selection and Installation Information for Lateral Wind Loads

Trusted WOOD I JOISTS SECTION: 06 ON WEB i. Conformity! ICC-ES Evaluation. Copyright 2015

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

ICC-ES Evaluation Report Reissued September 1, 2011 This report is subject to renewal in two years.

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

Joint Evaluation Report

Wood Design for Architects: Engineering for the Non-engineer. AIA Statement

Prescriptive Residential Wood Deck Construction Guide with Commentary DCA IRC Version (BCD 306)

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

GP LAM Laminated Veneer Lumber Georgia-Pacific Wood Products South LLC Revised March 20, 2015

Method for Increased Buckling Capacity of Built-Up Beams and Columns

Residential Deck Guide

WOOD I-JOIST AWARENESS GUIDE

CHAPTER 5 FLOORS SECTION R501

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

Evaluation Report CCMC R LP SolidStart LVL

MAX-CORE I-JOIST DESIGN MANUAL-US

** REVISED BY THE CITY OF LOS ANGELES

Training Objectives Module A

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: NORDIC ENGINEERED WOOD

ESR ICC Evaluation Service, Inc. Issued May 1, 2008 This report is subject to re-examination in one year.

Commercial Design Manual for I-Joists. The GREEN. Building. Solution

LIMIT STATES DESIGN INFORMATION for Specific Engineering Design for New Zealand Construction

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC AND COMPOSITE FASTENINGS REPORT HOLDER:

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 International Residential Code

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code

O PEN J OIST SPECIFIER GUIDE

O PEN J OIST SPECIFIER GUIDE

Minimum required percentage of length of braced wall band on each storey 4

CONNECTOR SELECTION GUIDE

STANDARD RESIDENTIAL DECK DETAILS

FIGURE R502.2 FLOOR CONSTRUCTION

twelve wood construction: materials & beams ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2014 lecture

Kerto ENGINEERED TO PERFORM

Joint Evaluation Report ICC-ES (800) (562)

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

DECK PERMIT APPLICATION

Listing Report: MUR Reissue Date: 12/07/17 This report is subject to annual review

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

Lintels and Beams Engineering basis

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

PFC-5804* Reissued February 1, Filing Category: DESIGN Wood

GLOBAL LVL HEADERS, BEAMS AND COLUMNS. 2.0E-3300Fb User guide. lvlglobal.com

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California *Revised April 2003

Deep Depth TJI. TJI 560 TJI 560D Joists

WALL CONSTRUCTION CHAPTER 6

(800) (562) A Subsidiary of the International Code Council

Lintels and Beams: Engineering Basis

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION

Evaluation Report CCMC R Murphy LVL

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 Virginia Residential Code

Joint Evaluation Report ICC-ES (800) (562)

*Revised November 2003

C. Delegated-Design Submittal: For metal-plate-connected wood trusses indicated to comply with

twelve wood construction: materials & beams Wood Beam Design Wood Properties Timber National Design Specification

Transcription:

LAMINATED VENEER LUMBER Kerto LVL Beams, Headers, Rafters and Columns for Floor and Roof Applications. USA VERSION

KERTO LAMINATED VENEER LUMBER TABLE OF CONTENTS Design Properties... 2 Allowable Uniform Load Table Notes... 3 1-3/4" Kerto-S Maximum uniform load (plf) 100% for floor loads...4-5 1-3/4" Kerto-S Maximum uniform load (plf) 115% for roof loads (snow)... 6-7 1-3/4" Kerto-S Maximum uniform load (plf) 125% for roof loads (non snow)...8-9 Installation Details for Roofs and Floors...10 Allowable Holes for Uniformly Loaded Beams... 11 3-1/2 and 5-1/4 Kerto-S LVL Columns...12 Multiple Member Connections for Side Loaded Beams...13 Simpson Strong-Tie Connectors for 1-3/4 Kerto-S LVL...14 USP Connectors for 1-3/4 Kerto-S LVL...15 KERTO-S MAIN APPLICATIONS Beams Headers Floor joists Roof rafters Columns Studs Truss Chords Tall wall and long length framing Components for modular construction Industrial and commercial applications Components for manufactured housing Stair stringers Concrete formwork Scaffold boards KERTO-S LVL DESIGN PROPERTIES Flexural Stress (Beam) Flexural Stress (Plank) Tension Parallel to Grain Compression Parallel to Grain Compression Perpendicular to Grain F c 3 (psi) Horizontal Shear F v (psi) True MOE 6 (psi) F b 2, 4 (psi) F b (psi F t 5 (psi) F c (psi) Directions: Directions: Directions: Beam Plank Beam Plank Beam Plank 2900 3200 2300 2700 870 435 320 200 2.0x10 6 2.0x10 6 NOTES 1. Allowable design stresses are based on covered dry conditions of use. 2. The tabulated flexural stresses are based on loads of a normal duration and a referenced depth of 12 inches. For other depths, the tabulated flexural stress must be adjusted by a depth factor adjustment of (12/d) 0.15. For depths less than 3½ inches, use the value for 3½ inches. 3. The tabulated design stresses provided in this table are based on a normal duration. Loads of longer or shorter duration must be adjusted in accordance with the 2012, 2009, 2006 International Building Code, the 2012 2009, 2006 International Residential Building Code, as applicable. Duration of load factors must not be applied to Fc I and E. 4. The allowable bending stress increase for repetitive members must not exceed 4 percent. 5. The tabulated tension stress is based on a length of 55 inches (1397 mm). For lengths longer than 55 inches, tabulated tension stress must be adjustred by a factor of (55/L) 0.125. The tabulated values for lengths shorter than 55 inches must not be increased. 6. The values in this column reflect the true MOE which is the shear-free modulus of elasticity. When calculating deflection, both bending and shear deformations must be included. Equations for various span and load conditions are available in engineering references. For example, the equation for a simple-supported beam under uniform load is: = 270wL 4 /Ebd 3 + 28.8wL 2 /Ebd where: = Deflection in inches (in), w = Uniform load in pounds per lineal foot (plf), L = Design span in feet (ft), b = Beam width in inches (in), d = Beam depth in inches (in), and E = Shear free modulus of elasticity in pounds per square inch (psi) Refer to ICC-ES Evaluation Report ESR-3633 For additional information regarding Kerto-S Laminated Veneer Lumber (LVL). HANDLING, STORAGE AND INSTALLATION GUIDELINES: Warning: Failure to apply good building practices regarding application, handling, storage and installation of this product can result in poor performance and/or unsafe structures. Kerto-S LVL must be properly installed and braced before any loads are applied to the structure. Kerto-S LVL is to be used in a dry, well ventilated environment. Kerto-S LVL is not to be used for unintended purposes such as ramps or planks. Handle Kerto-S LVL carefully to avoid damage. Store the product on stickers on a clean, level surface and keep it dry. Use appropriate personal protection equipment for handling and working with wood products; including but not limited to eye protection and gloves. 2 KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION

ALLOWABLE UNIFORM LOAD TABLE NOTES KERTO-S LVL DESIGN PROPERTIES FOR WIDTH AND DEPTHS USED IN THIS PRODUCT GUIDE Width Design Property Depth 7¼ 9¼ 9½ 11¼ 11 7 8" 14 16 18 20 24 Moment (ft-lbs) 3996 6271 6588 9008 9955 13499 17282 21490 26115 36591 1¾ Shear (lbs) 2707 3453 3547 4200 4433 5227 5973 6720 7467 8960 Moment of Inertia (in4) 56 115 125 208 244 400 597 851 1167 2016 Weight (plf) 2.8 3.6 3.7 4.4 4.6 5.4 6.2 7.0 7.8 9.3 GENERAL NOTES FOR USING THIS PRODUCT GUIDE AND UNIFORM LOAD (PLF) TABLES 1. Tables are for simple span beams (with a support at each end) and uniformly distributed loads. 2. Continuous lateral restraint must be provided at the top (compression) edge of the beam to prevent buckling. 3. For other span, load or restraint conditions, design the beam using Finnwood software, istruct software or other competent analysiss. 4. Lateral restraint is required at supports to prevent rotation of the beam. LOADS: 5. There are three sets of Load Tables: 100% for Floor Loads, 115% for Roof Loads (Snow), 125% for Roof Construction Loads (Non Snow). Refer to the NDS (National Design Specification for Wood Construction) Section 2.3.2 for more information about load duration. 6. In order to satisfy both deflection and strength requirements for beam design, live load for floors, live or snow load for roofs as well as total load (live or snow + dead load) must be considered. 7. Uniform load tables in this product guide have values for Live (or Snow) load as well as Total load. The user must calculate both uniform load values in pounds per linear foot (PLF). 8. Additionally, two deflection limits are listed for Live (or Snow) loads; the value typically required by the building code and a more stringent or higher performance value. The user must verify the requirements for the application and decide the appropriate deflection value to use. 9. The self weight of the beam is allowed for in the loads shown. It is not necessary to add the self weight of the beam to the calculated total load. MULTIPLE PLIES: 10. Loads are for one ply (member) 1-3/4 thick. Multiply the loads: x 2 for 2 ply beams, x 3 for 3 ply beams, x 4 for 4 ply beams 11. Beam plies (members) must be adequately connected by nails, screws or bolts as specified in this product guide or by competent analysiss. 12. Two (2) or more 1-3/4 plies are recommended for depths greater than 14 inches. If a single 1-3/4 member deeper than 14 is used; pay particular attention to stability, lateral restraint and connections. Make sure these structural details are provided and properly installed. 13. 4 ply beams require bolts or long screws which are specifically manufactured to connect all the plies of a multiple ply beam. 4 - ply beams must be top loaded or loaded equally from both faces. 14. Refer to the multiple ply connection information in this product guide for specific fastener information for connecting the plies. Note: Connection requirements depend on whether loads are applied equally to each ply (Typically when beam is top loaded). Or if loads are applied to one face of the multiple ply beam. For loads applied to one face; additional connections and lateral restraint may be required to avoid torsional loads/stresses in the beam. BEARINGS: 15. Make sure bearings are structurally adequate to carry the loads and are in compliance with building codes and regulations. 16. Bearing widths shown are required to support the maximum PLF loads shown. If less than maximum PLF load is applied to the beam, tabulated bearing widths may be reduced proportionally as follows: Total Load applied/total Load from table. Refer to examples on PLF tables. 17. This value may be conservative, specific analysis may produce a better result. KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION 3

1-3/4" KERTO-S MAXIMUM UNIFORM LOAD (PLF) 100% FOR FLOOR LOADS HOW TO USE MAXIMUM UNIFORM LOAD (PLF) TABLES: 1. Calculate live load (PLF). Select a beam with equal or greater capacity for Live load. 2. Calculate total load (PLF). Select a beam with equal or greater capacity for Total load. The beam you select must satisfy both requirements: Live load and Total load. Example: A floor beam with 9 0 clear span carries 680 PLF live and 884 PLF total load. Refer to the Floor PLF Table for 1-3/4 x 11-7/8 Clear Span Defl/Brg 11 7 8" Live L/480 651 9 Live L/360 868 Total L/240 924 Brg (in.) 3.0 For 9 0 clear span: Live load capacity = 868 PLF which exceeds the live load requirement of 680 PLF This is selected for L/360 which is the usual deflection limit for floors required by the building code. Total load capacity = 924 PLF which exceeds the total load requirement of 884 PLF. 1-3/4 x 11-7/8 is satisfactory for this application KERTO-S MAXIMUM UNIFORM LOAD (PLF) 100% FOR FLOOR LOADS Clear Span Defl/Brg 7¼ 9¼ 9½ 11¼ 11 7 8" 14 16 18 20 24 6 7 8 9 10 11 12 13 14 15 Live L/480 480 998 1081 1691 1953 2548 3141 3645 4253 4555 Live L/360 640 1280 1344 1768 1953 2548 3141 3645 4253 4555 Total L/240 814 1280 1344 1768 1953 2548 3141 3645 4253 4555 Brg (in.) 3.0 3.0 3.0 4.5 4.5 6.0 7.5 9.0 12.0 12.0 Live L/480 324 639 692 1092 1285 1912 2369 2852 3358 4048 Live L/360 432 852 923 1319 1457 1912 2369 2852 3358 4048 Total L/240 625 950 997 1319 1457 1912 2369 2852 3358 4048 Brg (in.) 1.5 3.0 3.0 4.5 4.5 6.0 7.5 9.0 10.5 12.0 Live L/480 218 433 470 780 918 1438 1905 2301 2718 3601 Live L/360 291 578 626 1040 1068 1532 1905 2301 2718 3601 Total L/240 433 732 769 1053 1068 1532 1905 2301 2718 3601 Brg (in.) 1.5 3.0 3.0 3.0 3.0 4.5 6.0 7.5 9.0 12.0 Live L/480 154 307 333 553 651 1025 1470 1818 2218 2962 Live L/360 205 410 444 738 868 1221 1523 1818 2218 2962 Total L/240 304 582 610 837 924 1221 1523 1818 2218 2962 Brg (in.) 1.5 3.0 3.0 3.0 3.0 4.5 6.0 6.0 7.5 10.5 Live L/480 108 226 245 407 478 756 1129 1549 1840 2462 Live L/360 145 301 326 542 638 996 1266 1549 1840 2462 Total L/240 213 448 485 680 751 996 1266 1549 1840 2462 Brg (in.) 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 7.5 10.5 Live L/480 82 171 185 307 362 593 856 1180 1512 2107 Live L/360 109 228 247 410 482 787 1060 1290 1512 2107 Total L/240 160 338 365 564 623 787 1060 1290 1512 2107 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 6.0 6.0 9.0 Live L/480 63 132 143 238 280 459 665 919 1261 1788 Live L/360 85 176 191 317 373 612 887 1090 1327 1788 Total L/240 123 261 282 471 524 712 894 1090 1327 1788 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 6.0 6.0 9.0 Live L/480 50 104 113 188 221 363 527 750 1001 1564 Live L/360 67 139 151 251 295 484 702 951 1136 1564 Total L/240 96 205 221 371 437 607 764 951 1136 1564 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 7.5 Live L/480 40 84 91 151 178 291 435 604 807 1356 Live L/360 54 112 121 201 237 389 581 805 983 1356 Total L/240 77 164 177 297 350 524 622 822 983 1356 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 4.5 6.0 7.5 Live L/480 33 68 74 123 145 238 355 494 677 1115 Live L/360 44 91 99 164 193 317 474 658 860 1186 Total L/240 62 133 143 242 284 457 581 718 860 1186 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 4.5 4.5 7.5 >> 4 KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION

KERTO-S MAXIMUM UNIFORM LOAD (PLF) 100% FOR FLOOR LOADS Clear Span Defl/Brg 7¼ 9¼ 9½ 11¼ 11 7 8" 14 16 18 20 24 16 17 18 19 20 22 24 26 28 30 Live L/480 56 61 102 120 196 293 408 560 947 Live L/360 75 82 136 160 262 391 545 747 1062 Total L/240 109 118 199 234 386 515 631 769 1062 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 Live L/480 47 51 85 100 164 245 342 469 794 Live L/360 63 68 113 133 219 327 456 626 943 Total L/240 90 97 165 194 322 456 560 682 943 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 Live L/480 40 43 72 84 138 207 295 396 672 Live L/360 53 57 96 113 185 276 393 529 843 Total L/240 76 81 139 163 270 406 484 608 843 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 4.5 6.0 Live L/480 34 37 61 72 118 176 251 338 573 Live L/360 45 49 81 96 157 235 335 451 757 Total L/240 64 69 117 138 229 345 454 546 757 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 3.0 4.5 6.0 Live L/480 31 52 62 101 151 216 291 494 Live L/360 42 70 82 135 202 288 388 658 Total L/240 58 100 118 196 295 410 493 684 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 6.0 Live L/480 76 114 163 223 379 Live L/360 102 152 217 298 506 Total L/240 146 220 317 396 572 Live L/480 59 88 125 172 293 Live L/360 78 117 167 230 391 Total L/240 111 168 242 335 480 Live L/480 46 69 99 136 231 Live L/360 62 92 132 181 309 Total L/240 86 131 189 262 408 Live L/480 37 55 79 109 186 Live L/360 49 74 106 145 248 Total L/240 67 103 150 208 351 Live L/480 30 45 64 88 153 Live L/360 40 60 86 118 205 Total L/240 54 83 120 167 287 Brg (in.) 3.0 3.0 3.0 3.0 3.0 Clear Span Defl/Brg 16 18 Live L/480 293 408 16 Live L/360 391 545 Total L/240 515 631 Brg (in.) 3.0 4.5 Example: A floor beam with 16 0 clear span carries 380 PLF live and 500 PLF total load. Refer to the Floor PLF Table for 1-3/4 x 16 Live load capacity = 391 PLF which exceeds the live load requirement of 380 PLF However If a higher performance beam is required with a live load deflection limit of L/480 Live load capacity = 293 PLF which does not meet the live load requirement of 380 PLF Refer to the Floor PLF Table for 1-3/4 x 18 Live load capacity = 408 PLF which exceeds the live load requirement of 380 PLF Total load capacity = 631 PLF which exceeds the total load requirement of 500 PLF 1-3/4 x 18 is necessary to meet a live load deflection limit of L/480 Required bearing = 4.5 for 631 PLF total load Since total load = 500 PLF then 500/631 x 4.5 = 3.6 bearing may be used. This value may be conservative, specific analysis may produce a better result. Note: Two (2) or more 1-3/4 plies are recommended for depths greater than 14 inches. Examples shown here are for loads on a single ply of a multiple ply member. KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION 5

1-3/4" KERTO-S MAXIMUM UNIFORM LOAD (PLF) 115% FOR ROOF LOADS (SNOW) HOW TO USE MAXIMUM UNIFORM LOAD (PLF) TABLES: 1. Calculate snow load (PLF). Select a beam with equal or greater capacity for Snow load. 2. Calculate total load (PLF). Select a beam with equal or greater capacity for Total load. The beam you select must satisfy both requirements: Live load and Total load. Example: A roof beam with 12 0 clear span carries 240 PLF snow and 360 PLF total load. Refer to the Roof PLF Table for 1-3/4 x 9-1/2 Clear Span Defl/Brg 9½ Live L/360 191 12 Live L/240 287 Total L/180 377 Brg (in.) 3.0 For 12 0 clear span: Snow load capacity = 287 PLF which exceeds the snow load requirement of 240 PLF This is selected for L/240 which is the usual deflection limit for roofs required by the building code. Total load capacity = 377 PLF which exceeds the total load requirement of 360 PLF. 1-3/4 x 9-1/2 is satisfactory for this application KERTO-S MAXIMUM UNIFORM LOAD (PLF) 115% FOR ROOF LOADS (SNOW) Clear Span Defl/Brg 7¼ 9¼ 9½ 11¼ 11 7 8" 14 16 18 20 24 6 7 8 9 10 11 12 13 14 15 Snow L/360 640 1253 1358 2025 2161 2821 3481 4116 4557 4555 Snow L/240 936 1415 1486 2025 2161 2821 3481 4116 4557 4555 Total L/180 936 1415 1486 2025 2161 2821 3481 4116 4557 4555 Brg (in.) 3.0 4.5 4.5 4.5 6.0 7.5 9.0 10.5 12.0 12.0 Snow L/360 410 852 923 1457 1677 2200 2726 3215 3743 4048 Snow L/240 615 1093 1147 1518 1677 2200 2726 3215 3743 4048 Total L/180 695 1093 1147 1518 1677 2200 2726 3215 3743 4048 Brg (in.) 3.0 3.0 3.0 4.5 4.5 6.0 7.5 9.0 12.0 12.0 Snow L/360 291 578 626 994 1170 1711 2128 2572 3040 3642 Snow L/240 437 843 885 1176 1299 1711 2128 2572 3040 3642 Total L/180 549 843 885 1176 1299 1711 2128 2572 3040 3642 Brg (in.) 1.5 3.0 3.0 4.5 4.5 6.0 7.5 9.0 10.5 12.0 Snow L/360 205 410 444 738 834 1367 1753 2124 2517 3309 Snow L/240 308 615 667 956 1035 1398 1753 2124 2517 3309 Total L/180 407 670 703 956 1035 1398 1753 2124 2517 3309 Brg (in.) 1.5 3.0 3.0 3.0 4.5 4.5 6.0 7.5 9.0 12.0 Snow L/360 145 301 326 542 638 1008 1433 1741 2068 2709 Snow L/240 217 452 490 783 864 1146 1433 1741 2068 2709 Total L/180 286 545 571 783 864 1146 1433 1741 2068 2709 Brg (in.) 3.0 3.0 3.0 3.0 3.0 4.5 6.0 7.5 9.0 10.5 Snow L/360 109 228 247 410 482 765 1105 1485 1767 2374 Snow L/240 164 342 370 615 717 952 1194 1485 1767 2374 Total L/180 215 451 473 649 717 952 1194 1485 1767 2374 Brg (in.) 3.0 3.0 3.0 3.0 3.0 4.5 6.0 6.0 7.5 10.5 Snow L/360 85 176 191 317 373 594 887 1225 1497 2018 Snow L/240 127 265 287 476 560 803 1030 1255 1497 2018 Total L/180 166 349 377 547 604 803 1030 1255 1497 2018 Brg (in.) 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 7.5 9.0 Snow L/360 67 139 151 251 295 484 702 973 1295 1768 Snow L/240 100 209 226 376 443 669 880 1075 1295 1768 Total L/180 130 275 297 466 515 669 880 1075 1295 1768 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 6.0 6.0 9.0 Snow L/360 54 112 121 201 237 389 566 805 1077 1534 Snow L/240 81 168 182 302 356 583 761 919 1132 1534 Total L/180 104 220 238 398 444 604 761 919 1132 1534 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 9.0 Snow L/360 44 91 99 164 193 317 462 658 881 1366 Snow L/240 66 137 148 247 290 476 664 827 989 1366 Total L/180 84 179 193 324 381 526 664 827 989 1366 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 7.5 >> 6 KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION

KERTO-S MAXIMUM UNIFORM LOAD (PLF) 115% FOR ROOF LOADS (SNOW) Clear Span Defl/Brg 7¼ 9¼ 9½ 11¼ 11 7 8" 14 16 18 20 24 16 17 18 19 20 22 24 26 28 30 Snow L/360 75 82 136 160 262 382 545 731 1205 Snow L/240 113 123 204 240 393 574 728 872 1205 Total L/180 147 159 267 314 463 584 728 872 1205 Brg (in.) 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 7.5 Snow L/360 63 68 113 133 219 327 456 626 1036 Snow L/240 94 102 170 200 329 491 645 761 1071 Total L/180 122 132 222 261 410 514 645 761 1071 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 4.5 7.5 Snow L/360 53 57 96 113 185 276 385 529 896 Snow L/240 80 86 144 169 277 414 576 701 949 Total L/180 102 110 187 220 363 469 576 701 949 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 Snow L/360 45 49 81 96 157 235 329 451 765 Snow L/240 68 74 122 144 236 353 493 629 873 Total L/180 87 93 158 186 308 420 517 629 873 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 Snow L/360 42 70 82 135 202 283 388 658 Snow L/240 63 105 124 203 303 424 568 788 Total L/180 79 135 159 264 379 467 568 788 Brg (in.) 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 Snow L/360 102 152 217 293 498 Snow L/240 153 228 326 439 652 Total L/180 197 297 390 469 652 Brg (in.) 3.0 3.0 3.0 4.5 6.0 Snow L/360 78 117 167 226 391 Snow L/240 118 176 251 340 541 Total L/180 150 227 326 394 541 Brg (in.) 3.0 3.0 3.0 4.5 4.5 Snow L/360 62 92 132 181 309 Snow L/240 93 139 198 272 463 Total L/180 117 177 255 334 471 Snow L/360 49 74 106 145 248 Snow L/240 74 111 159 218 372 Total L/180 92 141 203 281 406 Snow L/360 40 60 86 118 202 Snow L/240 61 91 129 177 303 Total L/180 74 113 163 227 352 Clear Span Defl/Brg 16 18 Snow L/480 202 283 20 Snow L/360 303 424 Total L/240 379 467 Brg (in.) 3.0 4.5 Example: A roof beam with 20 0 clear span carries 300 PLF snow and 400 PLF total load. Refer to the Roof PLF Table for 1-3/4 x 16 Snow load capacity = 303 PLF which exceeds the snow load requirement of 300 PLF Total load capacity = 379 PLF which does not meet the total load requirement of 400 PLF Refer to the Floor PLF Table for 1-3/4 x 18 Snow load capacity = 424 PLF which exceeds the snow load requirement of 300 PLF Total load capacity = 467 PLF which exceeds the total load requirement of 400 PLF 1-3/4 x 18 is required to meet the total load capacity. Required bearing = 4.5 for 467 PLF total load Since total load = 400 PLF then 400/467 x 4.5 = 3.9 bearing may be used. This value may be conservative, specific analysis may produce a better result. Note: Two (2) or more 1-3/4 plies are recommended for depths greater than 14 inches. Examples shown here are for loads on a single ply of a multiple ply member. KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION 7

1-3/4" KERTO-S MAXIMUM UNIFORM LOAD (PLF) 125% FOR ROOF LOADS (NON SNOW) HOW TO USE MAXIMUM UNIFORM LOAD (PLF) TABLES: 1. Calculate roof live load (PLF). Select a beam with equal or greater capacity for roof Live load. 2. Calculate total load (PLF). Select a beam with equal or greater capacity for Total load. The beam you select must satisfy both requirements: Live load and Total load. Example: A roof beam with 12 0 clear span carries 420 PLF roof live load and 630 PLF total load. Refer to the Floor PLF Table for 1-3/4 x 11-7/8 Clear Span Defl/Brg 11 7 8" Live L/360 373 12 Live L/240 560 Total L/180 657 Brg (in.) 3.0 For 9 0 clear span: Live load capacity = 560 PLF which exceeds the live load requirement of 420 PLF This is selected for L/240 which is the usual deflection limit for roofs required by the building code. Total load capacity = 657 PLF which exceeds the total load requirement of 630 PLF. 1-3/4 x 11-7/8 is satisfactory for this application KERTO-S MAXIMUM UNIFORM LOAD (PLF) 125% FOR ROOF LOADS (NON SNOW) Clear Span Defl/Brg 7¼ 9¼ 9½ 11¼ 11 7 8" 14 16 18 20 24 6 7 8 9 10 11 12 13 14 15 Live L/360 640 1253 1358 2126 2349 3067 3646 4375 4557 4555 Live L/240 961 1538 1615 2126 2349 3067 3646 4375 4557 4555 Total L/180 1018 1538 1615 2126 2349 3067 3646 4375 4557 4555 Brg (in.) 3.0 4.5 4.5 6.0 6.0 7.5 9.0 12.0 12.0 12.0 Live L/360 410 852 923 1457 1629 2314 2868 3455 4050 4048 Live L/240 615 1188 1213 1650 1763 2314 2868 3455 4050 4048 Total L/180 756 1188 1213 1650 1763 2314 2868 3455 4050 4048 Brg (in.) 3.0 3.0 3.0 4.5 6.0 7.5 9.0 10.5 12.0 12.0 Live L/360 291 578 626 994 1170 1834 2314 2796 3269 3642 Live L/240 437 867 940 1279 1413 1860 2314 2796 3269 3642 Total L/180 549 917 962 1279 1413 1860 2314 2796 3269 3642 Brg (in.) 1.5 3.0 3.0 4.5 4.5 6.0 7.5 9.0 10.5 12.0 Live L/360 205 410 444 709 834 1313 1857 2250 2667 3309 Live L/240 308 615 667 1019 1126 1488 1857 2250 2667 3309 Total L/180 407 728 764 1019 1126 1488 1857 2250 2667 3309 Brg (in.) 1.5 3.0 3.0 4.5 4.5 6.0 7.5 9.0 10.5 12.0 Live L/360 145 301 326 542 615 1008 1452 1893 2249 3011 Live L/240 217 452 490 814 918 1246 1559 1893 2249 3011 Total L/180 286 592 621 852 918 1246 1559 1893 2249 3011 4.5 6.0 7.5 9.0 12.0 Live L/360 109 228 247 410 482 765 1105 1523 1881 2495 Live L/240 164 342 370 615 724 1036 1298 1580 1881 2495 Total L/180 215 452 489 706 780 1036 1298 1580 1881 2495 Brg (in.) 3.0 3.0 3.0 3.0 3.0 4.5 6.0 7.5 9.0 10.5 Live L/360 85 176 191 317 373 594 860 1225 1628 2194 Live L/240 127 265 287 476 560 874 1097 1365 1628 2194 Total L/180 166 349 377 595 657 874 1097 1365 1628 2194 Brg (in.) 3.0 3.0 3.0 3.0 3.0 4.5 6.0 6.0 7.5 10.5 Live L/360 67 139 151 251 295 470 702 973 1298 1878 Live L/240 100 209 226 376 443 706 957 1169 1396 1878 Total L/180 130 275 297 497 560 747 957 1169 1396 1878 Brg (in.) 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 7.5 9.0 Live L/360 54 112 121 201 237 389 566 785 1077 1669 Live L/240 81 168 182 302 356 583 828 1012 1208 1669 Total L/180 104 220 238 398 469 623 828 1012 1208 1669 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 6.0 6.0 9.0 Live L/360 44 91 99 164 193 317 462 642 881 1452 Live L/240 66 137 148 247 290 476 693 885 1076 1462 Total L/180 84 179 193 324 381 573 722 885 1076 1462 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 6.0 6.0 9.0 >> 8 KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION

KERTO-S MAXIMUM UNIFORM LOAD (PLF) 125% FOR ROOF LOADS (NON SNOW) Clear Span Defl/Brg 7¼ 9¼ 9½ 11¼ 11 7 8" 14 16 18 20 24 16 17 18 19 20 22 24 26 28 30 Live L/360 36 75 82 136 160 262 382 545 731 1234 Live L/240 54 113 123 204 240 393 574 792 949 1311 Total L/180 68 147 159 267 314 504 636 792 949 1311 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 7.5 Live L/360 63 68 113 133 219 320 456 612 1036 Live L/240 94 102 170 200 329 480 684 842 1165 Total L/180 122 132 222 261 431 564 702 842 1165 Brg (in.) 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 7.5 Live L/360 53 57 96 113 185 271 385 518 878 Live L/240 80 86 144 169 277 406 578 753 1042 Total L/180 102 110 187 220 363 503 627 753 1042 Brg (in.) 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 7.5 Live L/360 45 49 81 96 157 235 329 451 750 Live L/240 68 74 122 144 236 353 493 677 937 Total L/180 87 93 158 186 308 458 563 683 937 Brg (in.) 3.0 3.0 3.0 3.0 3.0 3.0 4.5 4.5 7.5 Live L/360 42 70 82 135 202 283 388 658 Live L/240 63 105 124 203 303 424 582 858 Total L/180 79 135 159 264 396 508 619 858 Brg (in.) 3.0 3.0 3.0 3.0 3.0 4.5 4.5 6.0 Live L/360 102 152 213 293 498 Live L/240 153 228 320 439 710 Total L/180 197 297 418 511 710 Brg (in.) 3.0 3.0 4.5 4.5 6.0 Live L/360 78 117 167 226 385 Live L/240 118 176 251 340 578 Total L/180 150 227 326 429 597 Brg (in.) 3.0 3.0 3.0 4.5 6.0 Live L/360 62 92 132 181 309 Live L/240 93 139 198 272 463 Total L/180 117 177 255 334 500 Live L/360 49 74 106 145 248 Live L/240 74 111 159 218 372 Total L/180 92 141 203 281 442 Live L/360 40 60 86 118 202 Live L/240 61 91 129 177 303 Total L/180 74 113 163 227 384 Clear Span Defl/Brg 16 18 Snow L/480 271 385 18 Snow L/360 406 578 Total L/240 503 627 Brg (in.) 4.5 4.5 Example: A roof beam with 18 0 clear span carries 300 PLF roof live and 480 PLF total load. Refer to the Floor PLF Table for 1-3/4 x 16 Roof live load capacity = 406 PLF which exceeds the roof live load requirement of 300 PLF However If a higher performance beam is required with a live load deflection limit of L/360 Roof live load capacity = 271 PLF which does not meet the live load requirement of 300 PLF Refer to the Floor PLF Table for 1-3/4 x 18 Roof live load capacity = 385 PLF which exceeds the live load requirement of 300 PLF Total load capacity = 627 PLF which exceeds the total load requirement of 480 PLF 1-3/4 x 18 is necessary to meet a live load deflection limit of L/360 Required bearing = 4.5 for 627 PLF total load Since total load = 480 PLF then 480/627 x 4.5 = 3.5 bearing may be used. This value may be conservative, specific analysis may produce a better result. Note: Two (2) or more 1-3/4 plies are recommended for depths greater than 14 inches. Examples shown here are for loads on a single ply of a multiple ply member. KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION 9

INSTALLATION DETAILS FOR ROOFS Ridge Beam Kerto- S Ridge Beam must be properly designed & supported. Common rafters and connections must be properly designed. Hip & Valley Rafters Hip & Valley Rafters must be properly designed & supported. Common rafters and connections must be properly designed. Hip & Valley Rafter Cuts Hip or Valley Rafter is required to be full depth (uncut) at inside edge of bearing. Heel height Scarf Cuts Scarf Cuts are permitted for Kerto-S beams as specified in the table. Scarf cuts may be specially designed by software or other competent analysis. MAXIMUM REACTION FOR SCARF CUTS (lbs) Depth 7¼ 9¼ 9½ 11¼ 11 7 8" 14 16 18 1-1/2" bearing 2284 2284 2284 2284 2284 2284 2284 2284 3" bearing 2707 3453 3547 4200 4200 4328 4568 4568 4-1/2" bearing 2707 3453 3547 4200 4433 5227 5973 6720 Reactions are for 1 - ply 1-3/4" Kerto-S LVL. For 2 - plies multiply by 2. For 3 - plies multiply by 3 MINIMUM HEEL HEIGHT FOR SCARF CUTS (in) 1-1/2" bearing 6.1 6.1 6.1 6.1 6.1 6.1 6.1 6.1 3" bearing 7.3 9.3 9.5 11.3 11.3 11.6 12.2 12.2 4-1/2" bearing 7.3 7.3 9.5 11.3 11.9 14.0 16.0 18.0 INSTALLATION DETAILS FOR FLOORS Bearing at Wall Kerto-S Beam may require full width of wall plate for bearing. Rim board or blocking must be provided for lateral restraint to prevent rotation at support. Bearing at Concrete Wall Protect Kerto-S beam from direct contact with concrete as required by building code. Beam connection to wall must be designed and provided as required by building code. Bearing for Headers Provide adequate bearing for Kerto-S beam as specified in this product guide or designed by software or other competent analysis. Provide properly designed strap if top plate is not continuous over header. Bearing at Wood Column Provide properly designed column cap to carry Kerto-S beam reaction. Column cap must provide adequate lateral restraint to prevent rotation at support or other adequate restraint must be provided. Bearing at Steel Column Provide properly designed column cap to carry Kerto-S beam reaction. Column cap must provide adequate lateral restraint to prevent rotation at support or adequate restraint must be provided by framing or other means. Notches and holes Only circular holes are permitted DON'T: Cut rectangular or any other holes. Drill larger holes than permitted. Drill holes except in permitted zones. Notch Kerto-S LVL beams. Cope or notch beams over support 10 KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION

ALLOWABLE HOLES FOR UNIFORMLY LOADED BEAMS Min. 3x diameter of largest hole Allowable hole zone 1/4 d 1/2 d 1/4 d Min. 3x diameter of nearest hole (typical) 1. Only circular holes are permitted 2. 1-3/4" max. diameter, cut neatly with a drill or hole saw. 3. For other hole configurations, use Finnwood software, istruct software or other competent analysis. The following chart may be used to calculate circular holes for other span and loading conditions. Contact a design professional for analysis. ALLOWABLE SHEAR AND MOMENT CAPACITY FOR 1-3/4 KERTO-S LVL Beam Depth Max Hole Design Property Circular Hole Diameter 2 3 4 5 6 7 9¼" 3.7" 9½" 3.8" 11¼" 4.5" 11 7 8" 4.75" 14" 5.6" 16" 6.4" 18" 7.2" Shear (lbs.) 2450 2235 2029 Moment (ft. lbs.) 5370 5330 5330 Shear (lbs.) 2515 2300 2090 Moment (ft. lbs.) 5650 5595 5595 Shear (lbs.) 3010 2770 2525 2280 Moment (ft. lbs.) 7805 7650 7650 7650 Shear (lbs.) 3190 2930 2675 2420 Moment (ft. lbs.) 8660 8470 8470 8470 Shear (lbs.) 3805 3510 3220 2930 Moment (ft. lbs.) 11891 11560 11460 11460 11460 Shear (lbs.) 4390 4070 3745 3420 3090 Moment (ft. lbs.) 15380 14925 14705 14675 14675 Shear (lbs.) 4990 4635 4280 3920 3565 3210 Moment (ft. lbs.) 19303 18710 18375 18245 18245 18245 NOTES for Allowable Shear and Moment Capacity Table 1. Only circular holes are allowed. 2. Holes must be less than 40% of the overall beam depth. 3. Holes must be located in the middle half of the beam depth (leaving at least 1/4 of the total beam depth above or below the hole. 4. Holes shall be clean cut and smooth. 5. No adjustment to MOE is required for holes within these requirements. 6. Multiple holes must be 3 diameters apart (edge to edge) and three diameters from any bearings or supports. 7. If two holes are cut into any single beam then the above values shall be reduced to 70% of the stated value in chart. 8. If thickness other than 1¾" is used then a ratio of the thickness multiplied by the chart value can determine the allowable load. 9. Beams with more than two holes cut into them are beyond the scope of this guide. KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION 11

3-1/2 AND 5-1/4 KERTO-S LVL COLUMNS KERTO-S LVL COLUMNS MAXIMUM ALLOWABLE AXIAL LOAD (LBS) Column Length 3-1/2" x 3-1/2" 3-1/2" x 5-1/4" 3-1/2" x 7-1/4" 5-1/4" x 5-1/4" 5-1/4" x 7-1/4" 100% 115% 125% 100% 115% 125% 100% 115% 125% 100% 115% 125% 100% 115% 125% 4 17000 18200 19200 21900 24200 25600 25200 28000 29700 40000 40000 40000 40000 40000 40000 5' 14400 15500 16100 18800 20300 21200 22000 24000 25200 40000 40000 40000 40000 40000 40000 6' 11800 12500 12800 15700 16700 17200 18800 20200 21000 38700 40000 40000 40000 40000 40000 7' 9700 10000 10300 13100 13700 14100 16000 16900 17500 34800 37600 39300 40000 40000 40000 8' 8000 8300 8400 10900 11400 11700 13600 14300 14700 30700 32700 33800 38300 40000 40000 9' 6700 6900 7000 9200 9600 9800 11600 12100 12400 26800 28300 29100 33800 35800 37000 10' 5600 5800 5900 7900 8100 8300 10000 10400 10600 23400 24500 25100 29800 31300 32200 11' 4800 4900 5000 6800 7000 7100 8700 9000 9200 20600 21400 21800 26300 27500 28200 12' 4200 4300 4300 5900 6100 6200 7600 7900 8000 18100 18700 19100 23400 24300 24800 13' 3600 3700 3700 5200 5300 5400 6700 6900 7000 16000 16500 16800 20800 21600 22000 14' 3200 3200 3300 4600 4700 4700 6000 6100 6200 14300 14700 14900 18600 19200 19600 15' 12800 13100 13300 16800 17300 17600 16 11500 11800 12000 15100 15600 15800 17' 10400 10700 10800 13700 14100 14300 18' 9500 9700 9800 12500 12800 13000 19' 8600 8800 8900 11400 11700 11900 20 7900 8100 8100 10500 10700 10900 21' 7300 7400 7500 9700 9900 10000 21' 8100 8200 8300 10700 10900 11000 NOTES 1. Column table is suitable for interior columns with axial loads, no lateral loads. 2. Provide adequate column base supports for vertical loads and lateral restraint. 3. Provide adequate column connections at top for vertical loads and lateral restraint. 4. Loads in table are calculated with an eccentricity of 1/6 of either section dimension to produce the worst case. 5. For columns with lateral loads use Finnwood software, istruct software or other competent analysis. MULTIPLE MEMBER CONNECTIONS GENERAL NOTES 1. Maximum loads for fasteners are shown in the table on the facing page. 2. Connections are for uniform loads listed in this product guide. Concentrated or other load conditions require special design. 3. Make sure the load capacity of the beam meets or exceeds the load capacity of the fasteners. 4. 4 ply beams must be top loaded or loaded equally from both faces. For other load conditions, special design is required to avoid torsional stresses in the beam. 5. Do not use more than 4 plies for multiple member beams. MULTIPLE MEMBER CONNECTIONS FOR TOP LOADED BEAMS 1. Load must be equally distributed to each ply of the multiple member beam. 2. Use the minimum connections; nails, bolts or screws from the SIDE LOADED table. MULTIPLE MEMBER CONNECTIONS FOR SIDE LOADED BEAMS 1. Loads may be applied to either or both faces of the beam. Make sure load applied to either face does not exceed the value in the table. 2. Maximum Uniform Loads (PLF) shown in the table are for normal load duration. Appropriate Load Duration Factors may be applied to the values as permitted by the building code. INSTALLATION NOTES: Nails: Offset nails at least 2 from nails in adjacent ply to avoid splitting. Screws: Head side Point side 1. Drive screws from opposite face between screws in row as shown. 2. Install screws according to manufacturer s instructions. 3. SDW screws. End distance = 6 12 KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION

MULTIPLE MEMBER CONNECTIONS FOR SIDE LOADED BEAMS MAXIMUM UNIFORM LOAD (PLF) APPLIED TO EITHER FACE OF 2 -PLY & 3-PLY BEAMS. APPLIED EQUALLY TO BOTH FACES OF 4-PLY BEAMS. Fastener Type Rows Spacing in a row 2 - ply 1 3/4 " (3 1/2" wide) 3 - ply 1 3/4 " (5 1/4" wide) 4 - ply 1 3/4 " (7" wide) 7 1/4" to 11 7/8" 14" to 18" < 18" to 24" 7 1/4" to 11 7/8" 14" to 18" < 18" to 24" 7 1/4" to 11 7/8" 4" to 18" < 18" to 24" 16d common nails 0.162 x 3 1/2" 16d pneumatic "gun" nails 0.131 x 3 1/4" 2 12" 520 390 3 12" 780 780 585 585 4 12" 1040 1040 1040 780 780 780 2 12" 360 270 3 12" 540 540 405 405 4 12" 720 720 720 540 540 540 4 - ply connections require bolts or screws 4 - ply connections require bolts or screws 1/2" Diameter A307 Bolts with Fender Washers each face 2 24" 500 500 375 375 333 333 2 16" 750 750 562 562 500 500 3 24" 750 750 562 562 500 500 3 16" 1125 1125 843 843 750 750 Simpson Strong-Tie SDS Screws USP WS Screws Screw length 3-1/2" One face Screw length 3-1/2" Both faces Screw length 6" Both faces 2 24" 490 490 367 367 326 326 2 16" 735 735 551 551 490 490 3 24" 735 735 735 551 551 551 490 490 490 3 16" 1102 1102 1102 826 826 826 735 735 735 2 24" 586 586 439 439 390 390 2 16" 879 879 659 659 586 586 3 24" 879 879 879 659 659 659 586 586 586 3 16" 1318 1318 1318 988 988 988 879 879 879 Simpson Strong-Tie SDW Screws FastenMaster TrussLOK Screws Screw length 3 3/8" One face Screw length 5" One face Screw length 6 3/4" One face 2 24" 510 510 385 385 340 340 2 16" 765 765 577 577 510 510 3 24" 765 765 765 577 577 577 510 510 510 3 16" 1147 1147 1147 866 866 866 765 765 765 2 24" 436 436 384 384 341 341 2 16" 654 654 573 573 511 511 3 24" 654 654 652 573 573 573 511 511 511 3 16" 980 980 980 860 860 860 767 767 767 KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION 13

SIMPSON STRONG-TIE CONNECTORS FOR 1-3/4 KERTO-S LVL Top Mount Face Mount Depth Model Seat Length Fastener Type Load Seat Fastener Type Uplift Model Header Beam (100%) Length Header Beam Uplift Load (100%) 1¾" Kerto LVL 7¼" LBV1.81/7.25 3 10-16d 2-10dx11 2 265 2910 HU7 21 2 16-16d 8-10dx11 2 1515 2050 9¼" LBV1.81/9.25 3½ 10-16d 2-10dx11 2 265 2910 HUS1.81/10 3 30-16d 10-16d 2580 4705 9½" MIT9.5 2½ 8-16d 2-10dx11 2 215 2550 HUS1.81/10 3 30-16d 10-16d 2580 4705 11¼" LBV1.81/11.25 2½ 10-16d 2-10dx11 2 265 2910 HUS1.81/10 3 30-16d 10-16d 2580 4705 11 7 8" BA1.81/11.88 2½ 16-16d 2-10dx11 2 265 4015 HUS1.81/10 3 30-16d 10-16d 2580 4705 14" BA1.81/14 2½ 10-16d 4-10dx11 2 265 4015 HUS1.81/10 3 30-16d 10-16d 2580 4705 2 Ply 1¾" Kerto LVL 7¼" WPU3.56/7.25 3¼ 7-16d 6-10dx11 2 1095 4700 HGUS48 4 36-16d 12-16d 2782 6415 9¼" HWU3.56/9.25 3¼ 8-16d 6-10d 1135 6335 HGUS410 4 46-16d 16-16d 3521 7825 9½" HWU3.56/9.5 3¼ 8-16d 6-10d 1160 6335 HGUS410 4 46-16d 16-16d 3521 7825 11¼" HWU3.56/11.25 3¼ 8-16d 6-10d 1135 6335 HGUS412 4 56-16d 20-16d 4388 8255 11 7 8" HWU3.56/11.88 3¼ 8-16d 6-10d 1160 6335 HGUS412 4 56-16d 20-16d 4388 8255 14" HWU3.56/14 3¼ 8-16d 6-10d 1135 6335 HGUS414 4 66-16d 22-16d 4742 8255 16" HWU3.56/16 3¼ 8-16d 6-10d 1160 6335 HGUS414 4 66-16d 22-16d 4742 8255 18" HWU3.56/18 3¼ 8-16d 6-10d 1160 6335 HGUS414 4 66-16d 22-16d 4742 8255 20" HWU3.56/20 3¼ 8-16d 6-10d 965 6335 N/A 24" HWI424 2½ 4-16d 4-10d 0 5100 N/A 3 Ply 1¾" Kerto LVL 7¼" WPU5.50/7.25 3 7-16d 6-10d 1095 4700 HGUS5.50/8 4 36-16d 12-16d 2782 6415 9¼" HWU5.50/9.25 3¼ 8-16d 6-10d 1160 6000 HGUS5.50/10 4 46-16d 16-16d 3521 7825 9½" HWU5.50/9.5 3¼ 8-16d 6-10d 1160 6000 HGUS5.50/10 4 46-16d 16-16d 3521 7825 11¼" HWU5.50/11.25 3¼ 8-16d 6-10d 1160 6000 HGUS5.50/12 4 56-16d 20-16d 4388 8255 11 7 8" HWU5.50/11.88 3¼ 8-16d 6-10d 1160 6000 HGUS5.50/12 4 56-16d 20-16d 4388 8255 14" HWU5.50/14 3¼ 8-16d 6-10d 1160 6000 HGUS5.50/14 4 66-16d 22-16d 4742 8255 16" HWU5.50/16 3¼ 8-16d 6-10d 1160 6000 HGUS5.50/14 4 66-16d 22-16d 4742 8255 18" HWU5.50/18 3¼ 8-16d 6-10d 1160 6000 HGUS5.50/14 4 66-16d 22-16d 4742 8255 20" HWU5.50/20 3¼ 8-16d 6-10d 965 6000 N/A 24" N/A N/A 4 Ply 1¾" Kerto LVL 9¼" GLTV49.25-2 5 10-16d 6-16d 1295 7500 HGUS7.25/10 4 46-16d 16-16d 3521 7825 9½" GLTV49.5-2 5 10-16d 6-16d 1295 7500 HGUS7.25/10 4 46-16d 16-16d 3521 7825 11¼" HGLTV411.25-2 6 18-16d 6-16d 1295 10500 HGUS7.25/12 4 56-16d 20-16d 4388 8255 11 7 8" HGLT411.88-2 6 18-16d 6-16d 1295 10500 HGUS7.25/12 4 56-16d 20-16d 4388 8255 14" HGLT4114-2 6 18-16d 6-16d 1295 10500 HGUS7.25/14 4 66-16d 22-16d 4742 8255 16" HGLT416-2 6 18-16d 6-16d 1295 10500 HGUS7.25/14 4 66-16d 22-16d 4742 8255 18" HGLT418-2 6 18-16d 6-16d 1295 10500 HGUS7.25/14 4 66-16d 22-16d 4742 8255 20" HGLT420-2 6 18-16d 6-16d 1295 10500 N/A 24" HGLT7.12/24 6 18-16d 6-16d 1295 10500 N/A Images courtesy of Simpson Strong-Tie 14 KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION

USP CONNECTORS FOR 1-3/4 KERTO-S LVL Top Mount Face Mount Depth USP Model Seat Length Fastener Type Load Seat Fastener Type Uplift Model Header Beam (100%) Length Header Beam Uplift Load (100%) 1¾" Kerto LVL 7¼" PHXU17725 3¼ 8-16d 6-10dx11 2 1035 4420 HD1770 2 14-16d 4-10dx11 2 660 1775 9¼" BPH17925 2 3 8 10-16d 4-10dx11 2 625 3340 HUS179 3 30-16d 10-16d 2595 4465 9½" BPH1795 2 3 8 10-16d 4-10dx11 2 625 3340 HUS179 3 30-16d 10-16d 2595 4465 11¼" BPH17112 2 3 8 10-16d 4-10dx11 2 625 3340 HUS179 3 30-16d 10-16d 2595 4465 11 7 8" BPH17118 2 3 8 10-16d 4-10dx11 2 625 3340 HUS179 3 30-16d 10-16d 2595 4465 14" BPH1714 2 3 8 10-16d 4-10dx11 2 625 3340 HUS179 3 30-16d 10-16d 2595 4465 2 Ply 1¾" Kerto LVL 7¼" PHXU35725 3¼ 8-16d 6-10d 1290 6650 N/A 9¼" PHXU35925 3¼ 8-16d 6-10d 1290 6650 THDH410 4 46-16d 12-16d 2620 7190 9½" PHXU3595 3¼ 8-16d 6-10d 1290 6650 THDH410 4 46-16d 12-16d 2620 7190 11¼" PHXU35112 3¼ 8-16d 6-10d 1290 6650 THDH412 4 56-16d 14-16d 3055 7875 11 7 8" PHXU35118 3¼ 8-16d 6-10d 1290 6650 THDH412 4 56-16d 14-16d 3055 7875 14" PHXU3514 3¼ 8-16d 6-10d 1290 6650 THDH414 4 66-16d 16-16d 3365 9705 16" PHXU3516 3¼ 8-16d 6-10d 1290 6650 THDH414 4 66-16d 16-16d 3365 9705 18" PHXU3518 3¼ 8-16d 6-10d 1290 6650 THDH414 4 66-16d 16-16d 3365 9705 20" PHXU3520 3¼ 8-16d 6-10d 1290 6650 THDH414 4 66-16d 16-16d 3365 9705 24" PHXU3524 3¼ 8-16d 6-10d 1290 6650 N/A 3 Ply 1¾" Kerto LVL 7¼" BPH55725 2¼ 10-16d 6-10d 815 3450 N/A 9¼" PHXU55925 3¼ 8-16d 6-10d 1290 6650 THDH610 4 46-16d 16-16d 3365 8295 9½" PHXU5595 3¼ 8-16d 6-10d 1290 6650 THDH610 4 46-16d 16-16d 3365 8295 11¼" PHXU55112 3¼ 8-16d 6-10d 1290 6650 THDH612 4 56-16d 20-16d 5280 10365 11 7 8" PHXU55118 3¼ 8-16d 6-10d 1290 6650 THDH612 4 56-16d 20-16d 5280 10365 14" PHXU5514 3¼ 8-16d 6-10d 1290 6650 THDH614 4 66-16d 22-16d 5280 10365 16" PHXU5516 3¼ 8-16d 6-10d 1290 6650 THDH614 4 66-16d 22-16d 5280 10365 18" PHXU5518 3¼ 8-16d 6-10d 1290 6650 THDH614 4 66-16d 22-16d 5280 10365 20" PHXU5520 3¼ 8-16d 6-10d 1290 6650 THDH614 4 66-16d 22-16d 5280 10365 24" N/A N/A 4 Ply 1¾" Kerto LVL 9¼" HLBH71925 6 15-NA16D-RS 6-16d 1605 10620 THDH7210 4 46-16d 12-16d 2525 7900 9½" HLBH7195 6 15-NA16D-RS 6-16d 1605 10620 THDH7210 4 46-16d 12-16d 2525 7900 11¼" HLBH71112 6 15-NA16D-RS 6-16d 1605 10620 THDH7212 4 56-16d 14-16d 2525 7900 11 7 8" HLBH71118 6 15-NA16D-RS 6-16d 1605 10620 THDH7212 4 56-16d 14-16d 2525 7900 14" HLBH7114 6 15-NA16D-RS 6-16d 1605 10620 THDH7214 4 56-16d 14-16d 3365 9615 16" HLBH7116 6 15-NA16D-RS 6-16d 1605 10620 THDH7214 4 66-16d 16-16d 3365 9615 18" HLBH7118 6 15-NA16D-RS 6-16d 1605 10620 THDH7214 4 66-16d 16-16d 3365 9615 20" HLBH7120 6 15-NA16D-RS 6-16d 1605 10620 THDH7214 4 66-16d 16-16d 3365 9615 24" HLBH7124 6 15-NA16D-RS 6-16d 1605 10620 HD7180 21 2 28-16d 8-10d 1375 3545 Images courtesy of USP Structural Connectors KERTO-S LAMINATED VENEER LUMBER PRODUCT GUIDE USA VERSION 15

CERTIFIED RAW MATERIAL Everything we do involves sustainability from managing forests sustainably to upgrading the renewable raw material to high-quality products. Currently, 90% of the wood Metsä Wood uses comes from certified forests, mainly PEFC. Forest certification covers sustainability from safety at work to biodiversity. It secures future growth of forests, and indicates the sustainability of wood. Our chain of custody management systems enable us to monitor the origin and logistics chain of the wood we purchase throughout the entire value chain. Our network allows for efficient, reliable logistics. SOFTWARE Kerto-S LVL may be designed using Finnwood software. Finnwood is a software program developed for the calculation of individual timber structures made of Kerto or other Metsä Wood products. (download from the Metsä Wood website) or CSD istruct design software. (Contact your Metsä Wood distributor) TRADEMARK CREDITS CSD and istruct are registered trademarks of Calculated Structured Designs, Inc. Kerto Is a registered trademark of Metsä Wood Strong-Tie and Strong-Drive Are registered trademarks of Simpson Strong-Tie Company, Inc. FastenMaster and TrusLOK Are registered trademarks of OMG, Inc. USP Structural Connectors Is a registered trademark of MiTek USA, Inc. Copyright February 2017 Metsä Wood. All rights reserved. Metsä Wood provides competitive and environmentally friendly wood products for construction, industry and distributor partners. The products are manufactured from northern wood, a sustainable raw material of premium quality. Metsä Wood is part of Metsä Group. For further information and sales contact WWW.METSAWOOD.COM METSÄ WOOD P.O.Box 50 02020 Metsä, Finland Tel. +358 1046 05 METSÄ WOOD USA 3071 Commerce Drive, Suite E Fort Gratiot, MI 48059, USA 1 (800) 622-5850