gke Steri-Record Testsets and PCDs for validation, process and batch monitoring of sterilization processes

Similar documents
PRODUCT CATALOGUE. for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization

PRODUCT CATALOGUE. for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization

New methods to monitor steam penetration into complex medical devices (MD) using Medical Device Simulators (MDS) and Batch Monitoring Systems (BMS)

Hygiene Monitoring. Chemical Indicators, BD-Test and Batch- Product Information. CI_01_Eng

New methods to monitor steam penetration into complex medical devices (MD) using Medical Device Simulators (MDS) and Batch Monitoring Systems (BMS)

PRODUCT CATALOGUE. for gke Steri-Record Biological Indicators, Process Challenge Devices and Accessories

PRODUCT CATALOGUE. for gke Steri-Record Biological Indicators, Process Challenge Devices and Accessories

Product Catalogue. for gke Steri-Record Biological Indicators, Process Challenge Devices and Accessories

Instructions for Validation of Autoclaves

Consistent. Reliable. Innovative.

Secure. Tested. Certified.

SP MEDIKAL NEWS. We do hope, despite the economic situation, we again will gain a few distributors.

Hollow, porous, solid,? Testing of Steam Sterilizers

Quality Control EQUIPMENT CONTROL. Monitor critical performance characteristics of sterilization, decontamination or cleaning equipment

Bowie Dick Helix Test

Putting Confidence in Your Hands.

Advantages. Steam sterilization

Advantages. Steam sterilization

The Bowie & Dick test is used by manufacturers


They can be used on washer-disinfectors, ultrasonic cleaners, surgical instruments and endoscopes. Page 5

CERTIFICATE OF CONFORMANCE Mesa Laboratories, Inc. 625 Zoot Way, Bozeman, MT Phone: (303)

Sirona competency in hygiene DAC PROFESSIONAL. Hygiene systems. Vacuum autoclave class B to satisfy the most demanding requirements

Secure. Tested. Certified.

Hong Kong Sterile Services Management Association Limited. Seminar. 25 th June 2014

MEDICAL TRADING knows the meaning of sterilization very well: it can be

Technical Data Monograph. VERIFY All-In-One STEAM Reusable Test Pack

Sterilisation Monitoring Products

Best Practice Monitoring for Sterile Processing Professionals

Quality Control LOAD CONTROL. VERIFY Load Control Products. Use to monitor and release instrumentation with confidence RECORD KEEPING & LABELING


sterilisation monitoring products

Raven Labs. Sterility Assurance for Industry. Sterility Assurance Products Since A division of Mesa Laboratories, Inc.

NEW Faster, more versatile!

Objectives. The Perioperative Nurse s Role 6/24/2016. Instrument Processing & Sterilization Chesapeake Perioperative Consortium 2016

Medline Gemini Sterilization Wrap. Test Studies

Hygiene Monitoring. Biological Indicators for Monitoring Sterilization Processes. Product Information. BI_07_en

DUAL SPECIES BIOLOGICAL INDICATOR SPORE STRIPS For Monitoring Ethylene Oxide (EO), Steam and Chemiclave Processes

The Bowie and Dick Type Test Does size and penetration really matter?

INSTRUMENT CLEANING & STERILISATION FOAMING BATH FORMULATION. Surgistain. Rapid Multi-Enzyme Cleaner. Kimguard Sterile Wrap. Instrument brushes $32.

E9 Med. The strength of simplicity. Classification:

Stericool H 2 O 2. plasma sterilizers Affordable low temperature solution

NO 2 Gas Sterilization and Decontamination: Keeping Pace, from Start to Finish

Infection Control. Low Temperature Sterilization (LTS) Critical Aspects on Selection and Validation of LTS-Processes

NEW Faster, more versatile!

The Reusable Surgical Instrument Cycle

Part 1: General requirements

Population Catalog Number. Log Log Log Combined (both B. atrophaeus and G. stearothermophilus)

6 Handling, collection, and transport of contaminated items General rationale Separation of waste and reusable items at point of

6 Handling, collection, and transport of contaminated items General rationale Separation of waste and reusable items at point of

The new shape of sterilization

EN STERILINE 9.5. Class B and S sterilisation systems in compliance with international standards

Innovative. Smart. Trusted.

EBI 12 The new data logger generation

E10. The must of Euronda sterilization, in one single autoclave

3034 Owen Drive Antioch, TN USA Fax: Maybachstraße 10. Revised 01/17

LEADING TECHNOLOGY IN STERILIZATION

Steam Sterilization Monitoring in the New CSA Standard (Z )

CAN STERILE REALLY BE STERILE?: EFFECTIVE AUTOCLAVING METHODS

Nitrogen Dioxide (NO 2 ) PDA: A Global. Sterilization and. Association. Decontamination Systems. November 4, PDA Europe Parenterals 2014

Microbiology. Sample collection, cultivation, processing

TIP-GUARD INSTRUMENT PROTECTORS. Products Designed and Manufactured by the Scanlan Family Since 1921

ISO INTERNATIONAL STANDARD. Sterilization of health care products Chemical indicators Part 1: General requirements

E9 Next. Taking Class B sterilization to the next level. Classification:

THE BASICS OF STERILIZATION

Steam sterilization Process Challenge

Technical Data Monograph. VERIFY Assert Self-Contained Biological Indicators and VERIFY Assert STEAM Process Challenge Devices

Validation and Control of Porous Load Sterilisation

Standards: Overview and Up-date

Steam Sterilization Validation for Healthcare Institutions

Low Temperature Sterilization

Low temperature sterilization with hydrogen peroxide vapour; V-PRO TM applications & best practice

Hygeia. Her name is the origin of the word hygiene. DMB-Apparatebau GmbH 2009 Rudi Salzbrunn

Product range ROMA INSULATION SYSTEMS. Everything you need to know about ROMA and our products in one document.

STERILIZATION SOLUTIONS

FAQFrequently. Asked Questions. Education & Training. 3M Sterilization Assurance Techline

AMSCO 600 STEAM STERILIZERS QUALITY, PERFORMANCE AND RELIABILITY. Premium sterilization for today s CSSD. Central Sterile Services

Technology Overview. Ethylene Oxide

Biological Monitoring

REUSABLE MEDICAL DEVICE VALIDATION

ISO INTERNATIONAL STANDARD

Glass & Quartz Components

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

fax

Mediclave Autoclaves 6, 18 & 23 Litre B, S & N Class

SERCON 300 STEAM STERILIZERS. Full steam ahead. Reliable, flexible & efficient solutions. Central Sterile Services

Sterilization Policy. Georgia Regents Medical Center Policy Library. Policy Owner: Epidemiology POLICY STATEMENT

Substance WR4 Patinal

Sterilization. Euronda Spa t (+39) m euronda.com

INDUSTRIAL THERMOMETERS

STERILIZATION VALIDATION IN THIS SECTION REPROCESSING VALIDATIONS FOR REUSABLE MEDICAL DEVICES. Radiation Sterilization Validation

Plasma Low Temperature Sterilization. With vaporized hydrogen peroxide. PlazMax Line

Special Electrically Resistant Heated Furnaces

VHP M100 Biodecontamination Systems: Open Loop

Written By Dr. Robert Ramaley (Univ. NE Med CTR), Mia Ware, Dan Pearson, and Christopher R. Dwyer* (Raven Biological Laboratories)

8/27/2015. Learning Objectives. Purpose of Sterilization. To destroy all living pathogenic microorganisms

Cool when it counts. 3M Steri-Vac Sterilizer/Aerator GS Series. For Health Care Facilities

Technical Data Monograph. STERIS VHP LTS-V - Low Temperature Surfaces Terminal Sterilization

Ray s top tips: Things to consider when buying an Autoclave:

Process Filtration From Pure to Sterile

Transcription:

gke Steri-Record Testsets and PCDs for validation, process and batch monitoring of sterilization processes Application Process Monitoring Systems (PMS) are process challenge devices that are used to test sterilizers according to a defined standard, called type tests. A PMS checks if a sterilizer fulfils the requirements of the standard (e.g. BD Test according to EN 285 and Helix-Test according to EN 867-5). PMS are used for routine monitoring of sterilizer process parameters to proof insufficient air removal, leakage or non condensable gases (NCG). The gke Steri-Record PCD-Testsets (PCD = process challenge device) include various PMS and have been developed to test the penetration characteristics of the sterilization agent to ensure penetration inside hollow devices e.g. minimal invasive surgical (MIS) instruments and tubes. For a successful sterilization process the sterilizing agent must contact all inside and outside surfaces of the goods to be sterilized. Air and NCG must be removed from inside of hollow devices before they can be sterilized. Experience has demonstrated that most hollow devices and MIS instruments are more difficult to sterilize than porous loads (e.g. Bowie-Dick-Test). Sterility inside hollow instruments cannot be checked with parametric release and can only be correctly detected by using microbiological methods with direct inoculation. The results have to be evaluated in a microbiological laboratory after sterilization. This procedure is the only meaningful validation procedure but not feasible for routine monitoring. To circumvent direct inoculation alternatively a Testset can be used with biological or chemical indicators for steam, ethylene oxide, formaldehyde and hydrogen peroxide sterilization processes. The PCDs have different sensitivities and simulate simple solid instruments up to complex hollow devices. Depending on the selected Testset, the sterilizer must have a program with an appropriate fractionated vacuum or a deep single vacuum to enable air removal and sterilant penetration in the PCD. This characteristic depends on the sterilizer program used and differs from sterilizer brand to sterilizer brand. gke offers different Helix and Compact-PCD- Testsets, see order information table 1 + 2. The use of the gke Steri-Record Testsets allows a simple and inexpensive method to validate sterilization processes with hollow instruments. Information for steam sterilization processes: The Process Monitoring System (PMS) and Batch Monitoring System (BMS) for steam sterilization processes have been developed to monitor each cycle. BMS are validated according to the load configuration and are used for routine monitoring

of each batch. A PMS can also be used as a BMS if the penetration performance of the sterilizer exceeds the penetration performance of the load to be sterilized. As described before a selected PMS can be used for process or batch monitoring. The PMS has to be selected according to the sterilizer program, the BMS according to the load configuration. Small steam sterilizers, not operating with fractionated vacuum, are unable to remove air from longer hollow devices. In that case the PCD- Testset 200-013 or 200-210 for small sterilizers should be used to determine the length of inner lumens being able to get penetrated. Information for formaldehyde sterilization processes: The PMS for formaldehyde sterilization processes has been developed to monitor each cycle. According to EN 14180 the type test for formaldehyde sterilization processes is a hollow load test to be used as a process monitoring system according to EN 867-5 (Hollow Load Test). The chemical indicator set has been tested under the following conditions: 15 gas pulses Total sterilization time Evaporating solution between 53 and 200 mbar for 15 s each 60 min Temperature 60 C 2% formaldehyde in water There are various sterilization programs on the market. Before using a PCD as a PMS or BMS with other sterilization programs, validate the test using direct inoculation of the most difficult instrument by using biological indicators. For sterilization cycles without pressure difference processes, the PCD may not be suitable because of insufficient gas penetration. In this case seal indicator in one or more pouches without using the PCD. Information for ethylene oxide sterilization processes: The process challenge device (PCD) can be used with chemical or biological indicators (B. atrophaeus 10 6 ). The biological indicators must be incubated by a microbiological laboratory afterwards. Alternatively self-contained biological indicators (SCBI) can be used with special Bio-Compact-PCDs with the advantage that no laboratory is necessary to incubate the SCBIs. For routine monitoring chemical indicators are recommended with the advantage that they can be checked immediately after the sterilization process has finished. In opposite to steam sterilization processes different ethylene oxide sterilization processed are used which differ in temperature, pressure, ethylene oxide concentration and inert gas mixtures, e. g. CO 2. When chemical indicators are used, the monitoring system should be validated with biological indicators. The chemical indicator has been tested at 55 C under the following sterilization conditions: EO/l Pressure CO- 2 EO Time [mg] [bar] [%] [%] [min] 500 1,7 85 15 90 600 5,5 94 6 60 250 1,7 94 6 180 1200 5,5 85 15 30 600 0,5 0 100 60 During the EO-sterilization process it is absolutely necessary to monitor the relative humidity, which should be above 60%. The ideal relative humidity during sterilization is between 70% and 90% RH. If the standard type test (art.-no. 200-028) according to EN 1422 demonstrates successful ethylene oxide penetration the sterilizer meets the standard specifications for EO-penetration. Information for hydrogen peroxide (plasma) sterilization processes: The process monitoring system (PMS) for hydrogen peroxide (plasma) ensures that the H 2 O 2 gas penetrates into the most difficult locations of the load. The air removal and hydrogen peroxide penetration conditions differ heavily depending on the sterilization process/sterilizer used. Therefore, gke does not offer a fixed combination of biological or chemical indicator strip and process challenge device (PCD) but the selection of the PCD depends on the effectiveness of the hydrogen peroxide/plasma sterilization process and on the requirements of the load. It must be secured that the selected PCD represents the most difficult penetration characteristics of the load.

For selecting the appropriate test device your local gke sales partner or the gke laboratory may support you. After the right PCD is selected it can be ordered separately as a single PCD for routine monitoring together with biological or chemical indicators. In contrast to steam sterilization processes the penetration characteristics of H 2 O 2 in hydrogen peroxide sterilization processes into tubes become less difficult if the diameter of the tubes increases. Tube diameters below 4 mm are extremely difficult to be sterilized in hydrogen peroxide sterilization processes. Three different Testsets are offered. The PCD- Testset, 200-017, for sterilizers with fractionated vacuum contains 13 PCDs which are relatively hard to sterilize. The Testset, 200-013, for gravity displacement or overpressure cycles contains five PCDs with less demanding characteristics and the Testset, 200-016, contains 10 PCDs with tube dimensions that are optimized for hydrogen peroxide/plasma sterilization processes. All Helix-PCDs of the Testsets are available separately as well. The standard EN ISO 11140-1 defines six different indicator types. The gke hydrogen peroxide chemical indicator turns from blue to green (former purple to pink). Under the same conditions biological indicators (Geob. Stearothermophilus 10 6 CFU per strip) are inactivated. Since the hydrogen peroxide-/plasma sterilization processes are currently not standardized there are several different processes with different process parameters on the market. Therefore, it is recommended to validate a PMS once using biological indicators before routine monitoring with chemical indicators. Product Description gke produces two types of PCDs. Historically, so-called Helix-PCDs have been used which consist of a PTFE tube and a capsule to host the indicator. gke has decided to manufacture all capsules in stainless steel since they are more durable than plastic capsules. Also stainless steel has no negative catalytic effect with any of the sterilants used. The cap with the seal ring is durable in low and high temperature sterilization processes up to 140 C. 2. Compact-PCD s The gke Compact-PCD Testset contains 10 different Compact-PCD s. The specially designed and patented gke Compact-PCD consists of a large volume plastic case with stainless steel tubes of different lengths inside, with a minimal capsule volume at the end holding the indicator. They can be used with special gke chemical or biological indicators to monitor different sterilization processes. They can be put either vertically on a loading rack or placed horizontally on the bracket. All PCDs of the Testset are available separately as well. Helix-PCDs are durable for about 1.000 cycles while the most important parts of the patented Compact-PCD s are made of stainless steel and have an almost unlimited life span. 1. Helix-PCDs The gke Steri-Record PCD-Testsets contain different hollow test devices, consist of a tube with metal capsule, that can accommodate biological or chemical indicators with dimensions of 6 x 40 mm. The test devices are made of PTFE-tubes with different lengths and inner diameters, see table order information.

3. Chemical Indicators Indicators for all PCDs are available for steam, ethylene oxide, formaldehyde and hydrogen peroxide sterilization processes. All chemical indicators are protected by a polymer binder coating and therefore, do not release toxic substances and conform with EN ISO 11140 series. For colour change separate colour reference charts are available. The Hollow Load Test is described in the European Standard EN 867-5 and originally designed to test the steam penetration characteristics of class B table-top sterilizers according to EN 13060 and large sterilizers according to EN 285. However, in the meantime they are used for other applications as well. For formaldehyde sterilization processes this test is described as the hollow load test in EN 14180. The Helix-PCD (Art.-No. 200-150) as well as the Compact-PCD (Art.-No. 200-218) are hollow load tests according to EN 867-5. The Helix and the Compact-PCD have been validated by an accredited laboratory according to EN ISO 17025. All chemical indicators comply with the standard EN ISO 11140-1. 4. Biological Indicators gke offers biological indicators with different population and D-value for steam, formaldehyde, hydrogen peroxide, ethylene oxide and dry heat sterilization processes. Technical details are available in the data sheet for biological indicators. Biological indicators (spore strips) for H 2 O 2 sterilization processes contain a plastic carrier (free of cellulose) while other biological indicators are made of paper materials. Performance Characteristics The combination of a PCD and a biological or chemical indicator is a type 2 indicator system according to EN ISO 11140-1 consisting of a specific test load (PCD) and indicator (indicator strip). The chemical indicators have the performance characteristics of a type 5 indicator but the combination with a PCD is a type 2 indicator being able to monitor NCGs additionally not possible of a type 5 indicator only. All gke biological indicators comply with the standard EN ISO 11138 series. A standard for hydrogen peroxide/plasma is not published yet. Operational Description The PCD-Testset with the appropriate indicator inside is sterilized together with the load. At the end of the process the indicators are checked. As a result some PCDs show good penetration characteristics while some more demanding PCDs indicate fail conditions. The PCD that has passed with the highest hollow penetration resistance provides information about the best penetration characteristics of the process and may be used for routine monitoring. However it has to be demonstrated that this PCD has higher penetration characteristics than the load configuration. In case of doubt, validation according to DIN 58921 must be carried out. The selected PCD is also available as a single test device and can be used with the corresponding indicator strips for routine monitoring (see order information).

Benefits for Helix- and Compact-PCDs Testsets and PCDs are suitable for steam, ethylene oxide, formaldehyde and hydrogen peroxide sterilization processes using the correct gke indicator strip. Simple and easy method to find out the limitations of the penetration characteristics of a sterilizer. Only the use of a BMS allows the monitoring of sterility inside of complex hollow instruments, like tubes and porous goods not provided by recording pressure, temperature and steam quality in the chamber and/or using exposed indicator strips. PCDs are cost-effective due to multiple use. Only one indicator strip is required for each sterilization process instead of one in each pack. Easy interpretation of the results due to precise colour change. Continuous reproducibility of the results. Environmentally friendly, no unnecessary waste. All information relevant to the process is supplied on completion of the process so that the authorized person can release the batch without opening the packs. The graduated colour change of the indicator bars provides information about the magnitude of air removal and sterilant penetration inside the sterilizer. The indicator colour chemistry is a nonreversible chemical reaction and remains colourfast over time. All gke chemical indicators are protected from bleeding by a polymer binder and surface coating and can be disposed off with normal garbage. gke self-adhesive labels simplify recording with the gke Steri-Record documentation system. The screw-cap consists of a highly thermal resistant material and stainless steel sandwich-construction that protects hands from high temperatures. The indicator may be easily removed and evaluated on completion of each cycle. Additional benefits for Compact-PCD s: The advanced international patented multistage technology combines the penetration characteristics of hollow and porous loads simulating the Bowie-Dick test, Helix devices or various batch monitoring systems representing the characteristics of real loads such as textiles, tubes and even minimal invasive surgical (MIS) instruments. Compact-PCD s can be used for an unlimited number of cycles. The durable materials ensure reproducible results. The outside parts of the Compact-PCD s are made of thermal insulating material and protect the hands from high temperatures after taking the test device out of the sterilizer chamber. Results can be checked immediately at the end of the cycle.

Order information Helix-PCD-Testsets and single Helix-PCDs Art.-No.* Product code Content Application 200-017 PM-HPCD-TS-13 200-150 PM-HPCD-2-150 Testset consisting of 13 Helix-PCDs with metal capsule (see below) Tube diameter [mm] Tube length [cm] 150 200-302 PM-HPCD-2-300 2 300 200-452 PM-HPCD-2-450 450 200-153 PM-HPCD-3-150 150 3 200-303 PM-HPCD-3-300 300 200-154 PM-HPCD-4-150 150 4 200-304 PM-HPCD-4-300 300 To test steam and LTSF sterilization processes with fractionated vacuum 200-155 PM-HPCD-5-100 100 200-205 PM-HPCD-5-200 200 200-305 PM-HPCD-5-300 300 5 200-405 PM-HPCD-5-400 400 200-505 PM-HPCD-5-500 500 200-605 PM-HPCD-5-600 600 200-013 PM-HPCD-TS-5 Testset consisting of 5 Helix-PCDs with metal capsule (see below) 200-025 PM-HPCD-2-25 25 200-050 PM-HPCD-2-50 50 200-075 PM-HPCD-2-75 2 75 200-100 PM-HPCD-2-100 100 To test all sterilization processes with low demanding penetration characteristics 200-150 PM-HPCD-2-150 150 200-016 PM-HPCD-TS-10 Testset consisting of 10 Helix-PCDs with metal capsule (see below) 200-025 PM-HPCD-2-25 2 25 200-325 PM-HPCD-3-25 3 200-350 PM-HPCD-3-50 50 200-425 PM-HPCD-4-25 200-450 PM-HPCD-4-50 4 50 200-475 PM-HPCD-4-75 75 200-525 PM-HPCD-5-25 200-550 PM-HPCD-5-50 50 5 200-575 PM-HPCD-5-75 75 200-510 PM-HPCD-5-100 100 25 25 To test hydrogen peroxide sterilization processes

Compact-PCDs Testset and single PCDs Art.-No.* Product code Content 200-210 PM-RCPCD-TS Testset consisting of 10 Compact-PCDs (single PCDs see below) Sensitivity Reference load 200-211 PM-RCPCD-1 Equivalent to gke Tattoo-BMS (black) Tattoo 200-212 PM-RCPCD-2 PCD with higher penetration characteristics of the Tattoo-BMS and lower of the Dental-BMS No reference 200-213 PM-RCPCD-3 Equivalent to gke Dental-BMS (yellow) Dental 200-214 PM-RCPCD-4 PCD with higher penetration 200-215 PM-RCPCD-5 characteristics No reference 200-216 PM-RCPCD-6 Equivalent to gke Ophthal-BMS (white) Ophthalmology 200-217 PM-RCPCD-7 Equivalent to gke BMS (green) 200-218 PM-RCPCD-8 Equivalent to gke hollow load test (orange) 7 kg BD-cotton pack EN 285 with biological indicators Hollow load test according to EN 867-5 200-219 PM-RCPCD-9 High demand hollow load test (red) More demanding penetration characteristics than hollow load test 200-220 PM-RPCD-10 Very high demand hollow load test (brown) according to EN 867-5 Chemical and biological indicators for use in all testsets and PCDs The biological indicators for steam, formaldehyde and ethylene oxide sterilization processes are also available in larger quantities. Please see our product catalogue for biological indicators or ask for special quotation with staggered prices depending on the quantity. Art.-No.* Product Code Sterilization Process Content Description Chemical Indicators 211-255 211-252 C-S-PM-SV1 Steam 500 212-202 C-E-PM Ethylene oxide 213-203 C-F-PM Formaldehyde 214-203 C-V-PM Hydrogen peroxide 250 Refill pack with chemical indicator strips to be used in testsets and PCDs (see tables above) Biological Indicators Pop. Spore strips Content 223-501 B-S-F-SS-10-5 10 5 G. stearothermophilus Steam, Formaldehyde 223-601 B-S-F-SS-10-6 on paper carrier 332-601 B-V-SS-10-6 Hydrogen peroxide G. stearothermophilus 10 6 on PET plastic carrier 221-601 B-E-H-SS-10-6 Ethylene oxide, Dry heat B. atrophaeus on paper carrier 100 * A three digit letter code is added to the article number. The additional letter code refers to the language and/or customized version. It is only added on the outside label, the inside of the pack is identical with the article number in the above tables.

gke GmbH Auf der Lind 10 65529 Waldems-Esch Germany +49 (0) 61 26 94 32-0 +49 (0) 61 26 94 32-10 info@gke.eu http://www.gke.eu Your gke sales partner: 700-014 EN V06 12/2017