Flooded Type Water-Cooled Chillers. R134a

Similar documents
Air Cooled Chiller (50Hz) Air Cooled Scroll. Air Cooled Screw ACC 05/15

EPCE00-11A. Powerful. water cooled. Hydronic systems EUW*40-200KX

1 History. 2 Line-up

Free Cooling Technology

HIGH EFFICIENCY SHOWERS WASTE WATER HEAT RECOVERY UNIT. Saved power 80kW. Showers waste water 9 C Power consumption 3,1kW. Showers waste water 31 C

HITACHI Modular Chiller Solutions

Advanced heat driven cooling cycles for low-temperature waste heat recovery

6. What are the two main components of our environment? Answer. 7. Why are green plants called producers? Answer.

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Report on thermal cooling system implementation and performance

APPLICATION GUIDE Jan 2002

Explain how human activities can impact chemical cycles. Explain how pollution can affect food chains.

Deployment of a New Series of Eco Turbo ETI Chillers

Set Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that.

FAQ - OZONE DAY. Overview:

7/1/14. Using Content Enhancement Graphic Organizers to Support Essay Writing:

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

6-4 Charting a Course for the Future Slide 2 of 30

shedding on any DYNACIAT unit. CMS RS 485 MODBUS/JBUS LONWORKS (option)

TGG, TBG, TEG, TUG, 3.9 TBS, Gene-Link series

Environmental Science Std.-9 Chp.7 Atmosphere and Climate

i-chiller COMPACT 1 to 4 kw 0 C to 30 C ic03c to ic10c RELIABILITY:

ATOC OUR CHANGING ENVIRONMNET Class 2: Global Change (Chapter 1)

Largo & Allegro. Air Compressors. Largo & Allegro

WELCOME TO PERIOD 12: CONSEQUENCES OF USING CHEMICAL ENERGY Homework #11 is due today.

CELEBRATION OF THE WORLD OZONE DAY-2014 INTERNATIONAL DAY FOR THE PRESERVATION OF THE OZONE LAYER. Theme: Ozone layer protection -The mission goes on

AK SERIES (50Hz) ROOM AIR CONDITIONER AKY9FBSSW AKY9UBSSW. Models :

Sulfur oxides (SO x ) - particularly sulfur dioxide, a chemical compound with the formula SO 2. SO 2 is produced by volcanoes and in various

Nilan VPL Active heat recovery and cooling (air/air)

Directed Reading. Section: Global Change. than in the rest of the United States. b. In the United States and Canada, many lakes are dying as their ph

High Efficiency. 7 % on average. EFFICIENCY RATIO WHAT'S IMPROVED? APF: Annual Performance Factor. NS Type

Water-Cooled Screw Chillers and Water/Water Heat Pumps

MULTI SPLIT INVERTER SYSTEMS

high-efficiency performance High Performance, Comfort, respect for the environment

Greenhouse Effect. How we stay warm

Chapter: Conserving Resources

6-4 Charting a Course for the Future Slide 1 of 30

WHAT S INSIDE 17 THE EFFICIENCY OF HEAT PUMPS 18 REDUCE YOUR ENERGY CONSUMPTION 19 TECHNICAL SUPPORT 19 DECLARATION OF COMPLIANCE

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V

New Model Turbo Chiller, AART Series, Contributes to the Reduction of Energy Consumption under Year- Round Operation

9th Period Environmental Science Chapter 15: The Atmosphere

NATURAL REFRIGERANTS

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany

Pollution. Pollution refers any substance introduced into the environment that has harmful or poisonous effects

Smardt Water Cooled Chillers

Fiberglass Cooling Towers

Casterlin Environmental Systems pg. 1

1.6S PP SPUNBOND NONWOVEN PRODUCTION LINE. Ⅰ. Application

Chapter 11: Atmosphere

What Exactly is a Greenhouse Gas?

IT COOLING CHILLERS. NEW GENERATION OF AIR COOLED CHILLERS FOR IT COOLING APPLICATIONS. CAPACITY RANGE kw, SCROLL COMPRESSORS AND R410A

FACT SHEET 6 Transport Refrigeration

ROOF TOP PACKAGE UNITS

YKN2open A R C 032 A B

ACTIVA Rooftop. YKN2open. ARC-ARG-ARH-ARD A complete range from 48 kw up to 84 kw. Nomenclature A R C 045 B B. Features

Air-cooled Chillers with High Speed Centrifugal Compressors

york yvwa variable-speed, water-cooled, screw chillers Infinite chiller configurations to help you achieve your goals

Oil-Free Rotary Screw Air Compressors kw Horsepower

Environmental Impacts of. Energy Production

Your partner for the right solution

i-chiller 125 to 169 kw ic640 to ic660 ABOUT THE i-chiller RANGE ENERGY & PROCESS EFFICIENCY: RELIABILITY: EASE OF OPERATION & MAINTENANCE:

CASSETTE type (50Hz) SPLIT TYPE AIR CONDITIONER. Models Indoor unit Outdoor unit AUT25RLD-W AUT25ALD-W

Vocabulary for Section 1.1: Pressure. Atmosphere. Troposphere. Ionosphere O zone Layer. Ultraviolet radiation. Chlorofluorocarbon (CFC) Stratosphere

Module 2. Components of Global Change.

Daikin LXE10E Reefer Machine The industry s bestselling scroll reefer unit

Global Warming. By William K. Tong. Adjunct Faculty, Earth Science Oakton Community College

DEVELOPMENT OF A HIGH EFFICIENCY ABSORPTION CHILLER-HEATER AND A COMPACT ABSORPTION CHILLER-HEATER

Air Conditioners 4AC13

McQuay. Air Cooled Condensing Unit. ALP Vintage D. Last Manufactured: Replacement Parts List No Revision E 09/2016

TROPICS: insolation high year round, high sun angle and ~ constant duration

Atmosphere. Earth s Atmosphere

ASTRONOMY 161. Introduction to Solar System Astronomy. Class 16

EXPERIMENTAL STUDY OF ALTERNATIVE REFRIGERANTS TO REPLACE R134a IN A DOMESTIC REFRIGERATOR

Chapter: Conserving Resources

Section 4 The Air We Breathe

Biogeochemical Cycles

No ecosystems are completely isolated although the physical boundaries are not always obvious.

SAVE YOUR LIFE SAVE YOUR PLANET

HUMAN IMPACT ON THE ENVIRONMENT 02 OCTOBER 2013

Special edition paper Research on Utilizing Air Thermal Energy for Railway Facilities

AE R1 November, 2003

Water-cooled Chillers with High Speed Centrifugal Compressors

I. Pollutants A. Harmful substances the enter the environment

Sullair Water Chillers. Precision Chilled Water

Condensers & dry coolers ODIN. Excellent energy yield & sound characteristics

Geothermal Heating and Cooling Overview. Why should I consider it?

Acid deposition accumulation of potential acid-forming particles on a surface acids can result from natural causes

Stack Parking Surface Mounted Stackers

Air Cooled Condensing Units - Technical Catalog. Featuring Bitzer TM Compressors 404A and 507 Refrigerants

MODULE P2: RADIATION AND LIFE OVERVIEW

Threats to Our Atmosphere

HYDROCARBON REFRIGERANT CONVERSION REPORT FOR BOSCH SIEMENS HOME APPLIANCES CO CHUZHOU, CHINA.

An Integrated Solution for Commercial AC Chillers Using Variable Speed Scroll Compressors

JCM Proposed Methodology Form

Heat Pump Hot Water Supply Systems

Heating. Technical Data. Daikin Altherma hybrid heat pump EEDEN EVLQ-CV3

INVERTER ROOF TOP PACKAGE UNITS

3 - Environmental Ozone Indicators

Lecture 29 Air Pollution. Air Pollution. Clean Boundary Layer. Clean Boundary Layer

FITOCLIMA 600 & 1200 BIO

Transcription:

Flooded Type WaterCooled Chillers

The HighEfficiency WaterCooled Flooded Chillers The New WaterCooled Flooded chiller with improved efficiency and functionality by incorporating several advanced technology and features. This series with the world s best standard semihermetic screw compressors and newly designed shell and tube heat exchangers that have powerful cooling ability, low noise, low vibration, high efficiency and high reliability is the perfect answer to all your needs! Hitachi SemiHermetic Screw Chillers Show a Remarkable EnergySaving Effect & are Friendly to the Global Environment Global Warming Prevention Energy saving by higherefficiency screw chillers Global warming refers to the phenomenon of global rising in average atmospheric s due to increased volume of CO & methane as a result of burning fossil fuels such as petroleum and coal. The995 IPCC* Report predicted that if the emission of CO,etc. continued as it was, the atmospheric would rise by as much as C by the end of the st century and, as a result, the sea level would rise by approx. 50 cm from the present level. In such circumstances, it is even more important to save the energy consumed by air conditioners in order to cut CO emission. *IPCC: Intergovernmental Panel on Climate Change Ozone Layer Protection Use of HFC34a refrigerant has an ozone depletion potential of zero Chlorofluorocarbons (CFCs) in the stratosphere are exposed to ultraviolet rays which decompose them, and generate chlorine atoms. It is thought that the chlorine atoms combine with oxygen atoms in ozone to destroy the ozone. Because HFC34a has no chlorine atoms, it does not destroy the ozone in the atmosphere. Enhanced Lineup: from 43RT to 458RT Highperformance Semihermetic Screw s High efficiency shell & tubes flooded type evaporators High efficiency shell & tubes condensers Highly efficient external 3 stages oil separator, up to 99.96% oil separation Harmful ultraviolet rays Ozone layer destruction (ozone hole) Sun Ordinary ultraviolet rays Surface of earth Ozone layer Chlorofluorocarbons, etc. The ozone layer cuts harmful ultraviolet rays Chlorofluorocarbons destroy the ozone layer to generate ozone holes Ozone holes are expanded to increase harmful ultraviolet rays. Serious menace to the existence of terrestrial life Skin cancer, cataract and reduced harvests

Technical Features High COP In the new model series, the power consumption is largely reduced over the current model series due to newly designed highefficiency cooling system. High efficiency oil separation Precise Capacity Control Technology The of the chilled water outlet can be kept at the set ± C by continuous capacity control, so it is suitable for industrial use. Loadup signal sec. When there is a big difference between set and actual. 8 6 4 Start Outlet water A given load status is maintained. Inlet water sec. sec. Loaddown signal Loadup signal Stop Inlet water Outlet water Lapsed time The inlet water is detected at a stop, and it is restarted by a rise in inlet water. Neutral zone standard Stop standard Excellent Control Function 3 Design of external 3stages oil separator 4 Suction gas inlet Discharge gas outlet st stage nd stage 3rd stage Liquid Crystal Screen Display Big colorful liquid crystal touch panel Message board function (for shift) Real time information Screw compressor Return to factory setting Oil return valve 3rd stage Time starting function Image of Display To connect Venturi tube Building Management System (BMS) A BMSconnecting interface can be supplied. Gas exhaust baffle inlet Special design of 3stage oil separator outside, oil separates rate up to 99.96% and more Provided by HITACHI Condenser profile water Oil BMS System (Supplied by BMS Maker) Interface (option) Other Building System outlet Lighting Elevator Alarm Flooded Type WaterCooled Chillers

General Data Model Size Cooling Capacity Range Capacity Control Condenser Safety Device Flow Control Circuit Qty. Type Qty. kw RT % RCU40WFYZXB RCU85WFYZXB RCU30WFYZXB RCU80WFYZXB RCU330WFYZXB RCU370WFYZXB RCU40WFYZXB RCU460WFYZXB 503 43 654 86 805 9 006 86 57 39 308 37 459 45 60 458 00~5, 0 00~5, (.5)*,0 Orifice Plate Orifice Plate SemiHermetic Twin Screw SemiHermetic Twin Screw Shell & Tube Type Flooded Type Oil Temperature Sensor, Opto electronical Oil Level Monitor, Overcurrent Relay, High Pressure Switch, High/Low Pressure Sensor, Oil Heater, Motor Internal Thermostat, AntiFreeze Temperature Sensor, Phasereverse Protector, Discharge Temperature Sensor, Safety Relief Valve and Water Pressure Differential Switch Shell & Tube Type Flooded Type Oil Temperature Sensor, Opto electronical Oil Level Monitor, Overcurrent Relay, High Pressure Switch, High/Low Pressure Sensor, Oil Heater, Motor Internal Thermostat, AntiFreeze Temperature Sensor, Phasereverse Protector, Discharge Temperature Sensor, Safety Relief Valve and Water Pressure Differential Switch Condenser Piping Connection Piping Connection Inlet Inlet Outlet Outlet Outer Dimensions Length Width Height,997,469,95,997 3,037,95 Packing Dimensions L x W x H 3,30 x,670 x,0 (Single Module) 3,30 x,670 x,0 (Single Module) Module Qty. Net Weight Packed Weight kg kg 3,565 3,95 3,688 4,038 4,000 4,350 7,30 7,830 7,53 7,953 7,376 8,076 7,688 8,388 8,000 8,700 5 Notes. The nominal cooling capacities are based on the GB/T8430. 3. Working Range: 6 Chilled Water Inlet / Outlet Temperature: /7 C Cooling Water Outlet Temperature: C to 40 C Condenser Water Inlet / Outlet Temperature: 30/35 C Chilled Water Outlet Temperature: 5 C to 3 C. Applicable Power Source: Main Power Source (3 ) Control Power Supplies ( ) 4. ( ) marked with * is available by selection switch. 380V 50Hz 0V 50Hz 45V 50Hz 40V 50Hz Dimensional Data RCU40 to 30WFYZXB RCU80 to 460WFYZXB Operation Panel (LCD) Front Face Front Face 95±0 Switch for Urgent Stop Condensor Cooling Water Outlet (4 40) Chilled Water Outlet Oil Separator Electrical Control Box 95±0 Operation Panel (LCD) Switch for Urgent Stop (4 40) Condensor Cooling Water Outlet No. No. (4 40) Chilled Water Outlet Oil Separator Electrical Control Box Cooling Water Inlet 30 357.5 50 304 709 38 469±0 6 33 Chilled Water Inlet 400 Mounting Holes (4 6) 406 997±0 Cooling Water Inlet 30 357.5 304 709 605 54 709 50 38 50 38 3037±0 6 33 Chilled Water Inlet 400 Mounting Holes (8 6) 406 997±0 Flooded Type WaterCooled Chillers

http://www.jcihitachi.com Printed in Japan (H) HRE68Q Oct. 05