FLOW CYTOMETRY. CyAn ADP. Analyzer

Similar documents
NovoCyte Flow Cytometer

Boundary-breaking acoustic focusing cytometry

Your Research, Revolutionized

Designing and Implementing a High-Level Multicolor Flow Cytometry Assay. Brent Wood MD PhD Department of Laboratory Medicine University of Washington

Your Research, Revolutionized

Principles of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting. Shoreline Community College BIOL 288

Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE CLINICAL FLOW CYTOMETRY

Detecting human circulating endothelial cells using the Attune Acoustic Focusing Cytometer

BD FACSMelody. Cell Sorter. The simple solution for consistent, quality results

Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE FLOW CYTOMETRY

Flow Cytometry - The Essentials

Spherotech, Inc. 1. SPHERO TM Technical Note STN-8 Rev C

PowERFUL. INTUITIvE. customizable. ThE NEw STAR of. BENchToP FLow cytometry

BD FACSCanto II. A proven research platform for maximum reliability and the highest quality results

Flow Cytometry Immune Activation SOP

High-throughput automation with the Attune NxT Autosampler: consistent results across all wells and across plates

Each question may have MULTIPLE correct answers. Select all that are correct.

Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Visualization of digital data Interpretation of the visual

CyFlow Cube series Appealing from every angle

BD Accuri C6. Flow cytometry within reach.

Anatomy of a flow cytometer

Novel Developments in Cytometry. Martin Adelmann Marketing Manager Cellular Analysis & Life Science Beckman Coulter EMEAI

Attune NxT Acoustic Focusing Cytometer The next generation in acoustic cytometry

Reagent Titration for the ICS Assay

ab pdc Subset Phenotyping Kit

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Application Specialist BDBiosciences

Application Information Bulletin: DuraClone IM Tubes Compensation setup for high content DuraClone reagents

Cancer inflammation research applications and products

a Beckman Coulter Life Sciences: White Paper

Flow Cytometry SOP: Monocytes from Frozen Cells

determine optimum instrument settings for their own instruments and establish their own daily values.

CyFlow Space. Your Flexible Flow Cytometer.

Identification of red and white blood cells from whole blood samples using the Agilent 2100 bioanalyzer. Application Note

Application Note. Assay Portability on the BD FACSVerse System. Summary. Maria Jaimes, Yibing Wang, Catherine McIntyre, and Dev Mittar

Flow Cytometry SOP: 14 color flow for immune activation, senescence, and exhaustion

CyFlow Space Your flexible flow cytometer

Application Note. Yeast Analysis with a life - dead staining kit (Yeast control - viability)

BD LSRFortessa. Performance without peer, choice without compromise

Selecting Reagents for Multicolor Flow Cytometry

A previous ICCS Module entitled Instrument optimization - Adjusting PMT voltages and compensation 1 should be read as a prerequisite to this module.

Flow cytometry within reach.

Principles of Multicolor Panel Design BD. BD, the BD Logo and all other trademarks are property of Becton, Dickinson and Company.

Flexible, Intuitive and Affordable

BD Multicolor CompBeads

11/19/2013. Janine Zankl FACS Core Facility 13. November Cellular Parameters. Cellular Parameters. Monocytes. Granulocytes.

Cyto-Mine. The Single Cell Analysis and Monoclonality Assurance System

AMREP FLOW CYTOMETRY CORE FACILITY. Flow Cytometry Data Analysis Workshop Friday 24 th October

CyFlow Space Your flexible flow cytometer

Understanding Flow Cytometry

Beyond Colorful Science. A Practical Approach to Setting Up Multicolor Panels

InhibiScreen Kinase Inhibitor Assay

Minimum Information about a Flow Cytometry Experiment (MIFlowCyt) Annotation

ACTG Laboratory Technologist Committee Revised Version 2.0 ACTG Lab Man CD38 Quantitation 07 May 2004

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

Using Fluorescence Spillover to Advantage

Designing and executing a successful flow cytometry experiment

INTRODUCTION TO FLOW CYTOMETRY

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Assistant Product Manager BDBiosciences

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

What you need to know before designing a panel

The Worlds First Smart Flow Cytometer

CyFlow Cube 6. Immunology Microbiology Industrial Applications Agrosciences Aquaculture. Flow Cytometry: Simply elegant. Elegantly simple.

a Beckman Coulter Life Sciences: White Paper

Phagocytosis Assay Kit (IgG PE)

Best practices in panel design to optimize the isolation of cells of interest

Compensation: Fundamental Principles

CRC Flow Cytometry Core Facility Knut och Alice Wallenbergs Stiftelse

TECHNICAL BULLETIN. QUANTUM SIMPLY CELLULAR KIT Product Numbers QSC-20 AND QSC-100 Storage Temperature 2-8 C. Do Not Freeze

Challenges for Product Evaluation by Flow Cytometry for Cellular Therapy Product Processing Laboratories

BD LSR Cell Analyzer. Performance without peer, choice without compromise

DURACLONE IM ACCELERATE YOUR PACE IN IMMUNE SYSTEM RESEARCH. For Reseach Use Only - Not for use in Diagnostic procedures

SA3800 Spectral Analyzer

Challenges for Flow Cytometry in Regulated Bioanalysis

a Beckman Coulter Life Sciences: White Paper

flow cytometry reinvented

Incorporating New, Bright Fluorochromes into Multicolor Panel Design

GUAVA EASYCYTE SYSTEMS

Flowcytometry Dirk Pacholsky

BASICS OF FLOW CYTOMETRY

SA3800 Spectral Analyzer

SANTA CRUZ BIOTECHNOLOGY, INC.

Flow Cytometry Support Reagents

PURPOSE: To delineate the subsets of human lymphocytes based on the expression profiles of different phenotypic markers by FACS analysis

MoFlo Astrios High-Speed Cell Sorter

Welcome to the CORES Flow Cytometry Sorter Facility

Introduction to. BD FACSAria TM Cell Sorter. Flow = Fluid Cyto = Cell Metry = Measurement

Expanding Multicolor Options in Flow Cytometry with Novel Brilliant Violet TM Fluorophores. Carsten Wiethe Scientific Application Manager BioLegend

Protocol for FACS analysis of HeLa cell transfectants

Attune NxT Flow Cytometer

2. SUMMARY AND EXPLANATION

Review of techniques in imaging and cytometry. Peter Meeus Onze Lieve Vrouw Ziekenhuis, Aalst 7 may 2009, SCK/CEN Mol

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Cellometer Vision CBA

Ruud Hulspas, Mike Keeney, Ben Hedley and Andrea Illingworth

Hematopoietic Progenitor Cell Product Characterization

NovoCyte Quanteon F. Flow Cytometer. When Exceptional Performance Meets Simplicity

ENUMERATION OF LYMPHOCYTES SUBSETS (IMMUNOPHENOTYPING-IPT) (CD3, CD4, CD8, CD19 & CD16/56)

The NIAID Flow Cytometry Advisory Committee; the Guidelines Subcommittee

Selecting Fluorochrome Conjugates for Maximum Sensitivity

Transcription:

FLOW CYTOMETRY CyAn ADP Analyzer

Experience the Power of the CyAn ADP and its optimal performance The Power of Detection The Power of Speed The Power of Ease The CyAn ADP Analyzer is the next step in Advanced Digital Processing with enhanced detection for flow cytometry. The CyAn ADP has state-of-the-art optics, electronics, and fluidics offering automated compensation with the highest acquisition rates, easy to use walk-up operation on the smallest instrument footprint in its class. Dako offers two models to accommodate a diverse range of applications, with up to 11 standard parameters and 9 colors. Dako offers you an extensive standard range of high-quality The Power of Size monoclonal and polyclonal antibodies conjugated to FITC, RPE, RPE-Cy5, APC, Pacific Blue and Cascade Yellow. The Power of Choosing Us

Experience the Power of Detection and the precise results it gives you State-of-the-art optics provide enhanced performance for all applications including dim cell populations. High sensitivity and greater resolution for each parameter give you accurate results whether you are running a three color application or taking advantage of the nine colors available. > Peak performance in all channels > High sensitivity and greater resolution > Detect dimmest populations High-speed 9-color no-lyse analysis of human peripheral blood at a sample flow rate of 150 µl/min Panel Lambda/FITC, CD56/PE, CD19/PE-TR, CD4/PE-Cy5, CD5/PE-Cy7, CD8/PB, CD45/CY, Kappa/APC and CD3/APC-Cy7. Procedure 100 µl EDTA blood was washed twice in 20 ml PBS. 5 µl of 9-color mix was added to 50 µl of the washed cells. After 15 minutes incubation at room temperature in the dark, 500 µl PBS was added and the sample acquired on CyAn ADP at 150 µl/min. 7-color analysis of lysed and washed human peripheral blood Panel CD45/FITC, CD56/PE, CD3/PE-TR, CD14/PE-Cy5, CD4/PE-Cy7, CD19/APC, CD8/APC-Cy7 and additionally CD3/FITC and CD3/PE-Cy5 for compensation.

Experience the Power of Speed and maximize your workflow Bacterial viability 10 4 10 3 Injured Parallel processing of digital signals, a technology first patented by Dako, keeps you on the cutting edge with PI Log 10 2 Dead unmatched acquisition rates of up to 70,000 events per second. 10 1 Live > Ideal for rare event applications > Save time > Increase productivity 10 0 10 0 10 1 10 2 10 3 10 4 SYTO 9 Log 2M events in ~1 minute Yeast viability 10 4 10 3 High-speed screening for CMV-antigen-specific T-cells in unlysed human blood SS Log 10 2 Live Dead 10 1 10 0 10 0 10 1 10 2 10 3 10 4 FUN1 Log 2M events in ~1 minute Dendritic cells: rare event analysis 10 4 Figure 1 Control HLA-DR APC Log Comp 10 3 10 2 10 1 R3 CD123+ DCs Basophils R4 10 0 10 0 10 1 10 2 10 3 10 4 CD123 RPE Log Comp 2M events in ~1 minute Figure 2 CMV-antigen-specific T-cells 4-color reagent CD45/PB, CD3/FITC, CD8/APC, MHC Dextramer/PE. MHC Dextramer: HLA class 1 Allele A* 0201 loaded with HIV RT peptide ILKEPVHGV as control (Figure 1) or HCMVpp65 peptide NLVPMVATV (Figure 2). Procedure 6 µl of reagent was incubated with 100 µl EDTA treated blood for 15 minutes at room temperature. Subsequently the sample was diluted with 1 ml PBS and acquired on CyAn ADP at 150 µl/min. 9-color immunophenotyping at 150 µl/min HLA-DR CD8 PB APC Log Log Comp Comp 10 4 10 3 10 2 10 1 R3 CD123+ DCs Basophils R4 10 0 10 0 10 1 10 2 10 3 10 4 CD4 CD123 PE-CyS RPE Log Comp 163,000 CD45+ events in 2.3 minutes

Experience the Power of Ease and the peace of mind it gives you Summit software v4.3 interface puts advanced analysis at your fingertips. Flexible management tools allow you to define samples, workspaces, and monitor instrument status in parallel. > All processes on one screen > Utilize an intuitive software > Walk-up operation Summit Software v4.3 Summit software new version 4.3 is designed for your laboratory needs, with more power, advanced analysis tools, flexibility and greater ease of use. > Conveniently monitor and control instrument status > Define combinations of samples and workspaces that fit your workflow > Easily adjust compensation with auto-compensation feature > Define and use your individual protocols, compensation settings and workspaces for your experiments > Configure your acquisition batch, protocol panels, reagents and tubes Control fluidics in detail Create and group results in work spaces as needed Select extended statistics Write additional information or add files

Experience the Power of Ease and the peace of mind it gives you Auto-Compensate function in Summit Software v4.3 makes compensation easy in 2 steps The compensation matrix is calculated from single stained controls by the auto-compensate function in Summit software v4.3. Step 2 Summit software v4.3 guides you to obtain a full compensation matrix for multicolor analysis. Step 1 Simply select the files with data from single controls, select a gate if necessary and click OK. Iteration for CD3 FITC Apply Compensation Analysis of a 6-color-stained lysed and washed sample (CD4/FITC, CD56/PE, CD19/PE-Cy5,CD3/PB, CD45/CY and CD8/APC), lymphocytes gated on CD45/SSC. Example 10 µl of 6-color mix (CD4/FITC, CD56/PE, CD19/PE-Cy5, CD3/PB, CD45/CY and CD8/APC) was added to 100 µl EDTA peripheral blood and allowed to incubate for 20 minutes at room temperature in the dark. The blood was lysed with EasyLyse and washed in PBS before the data was acquired by a CyAn ADP. Utilize the Fast Acquisition / Analysis capability of CyAn ADP with Summit Software v4.3 Acquire and analyze up to 10 million events PBMCs were stained with a 7 color mix of titrated antibodies/ tetramers (CD62L/FITC, CMV specific tetramer B7 pp65 (417-426)/PE; the specificity of the stain was confirmed by HLA mismatch control tetramer B8 IE-1(88-96)/PE; CD4/PerCP, CD19/PB, CD3/CY, CD45RA/APC, CD8/APC-Alexa750), incubated for 20 minutes on ice in the dark, then washed with PBS 2.5 times. The dim tet stain was specific for the patient material applied. PI was added prior to acquisition with a CyAn ADP. 10M events, 8 colors, 37 parameters, 25K eps Acquired in 6.8 minutes, saved in 1.6 minutes, loaded in 25 seconds, gated in 1.8 minutes tetramer B7 pp65 (417-426)/PE Log Comp tetramer B7 pp65 (417-426)/PE Log Comp tetramer B7 pp65 (417-426)/PE Log Comp tetramer B7 pp65 (417-426)/PE Log Comp PI CD3/CY tetramer B7 pp65 (417-426)/PE CD8/APC Alexa750 Log Comp CD8/APC Alexa750 Log Comp CD8/APC Alexa750 Log Comp CD8/APC Alexa750 Log Comp CD19/PB CD8/APC Alexa750 Log Comp tetramer B7 pp65 (417-426)/PE 100,000 events 1M events 2M events 5M events

Experience the Power of Size and how it helps you configure your laboratory Effectiveness, efficiency and comfort are the most important goals when setting up a new laboratory or adding instrumentation. Many variables need to be considered, such as lighting, traffic flow, accessibility, hands-on time and adequate work space. > Compact footprint > Increase effectiveness, efficiency and comfort > Free table space The CyAn ADP is compact, fits anywhere, is easy to use and leaves more space on the workbench, giving you the flexibility to set up your laboratory according to your needs and daily priorities. The CyAn ADP footprint versus other instruments. 30 cm w x 45 cm d x 40 cm h 9 colors 182 cm w x 91 cm d x 61 cm h 90 cm w x 74 cm d x 61 cm h 91 cm w x 62 cm d x 67 cm h 90 cm w x 61 cm d x 64 cm h

Experience the Power of Choosing Us and a committed long-term partnership CyAn ADP Models Dako is the partner you are looking for. A friendly global team of dedicated specialists backed by decades of expertise in flow cytometry instrumentation and reagents provides you with modular and flexible solutions for your scientific needs. > Dedicated service > Professional training > Experienced application specialists CyAn ADP LX 7 Color CY 200 CyAn ADP LX 7 Color has 9 parameters (FSC, SCC, FL1-FL7) and is equipped with 488 nm and 635 nm solid-state lasers. This model is ideal for up to 7-color analysis using a combination of FITC, PE, PE-Texas Red, PE-Cy5 or PER-CP, PE-Cy7, APC and APC-Cy7 or other fluorochromes. Some key applications include CD34 enumeration, signal transduction, antigen-specific T-cell detection and multicolor immunophenotyping. CyAn ADP LX 9 Color CY 201 CyAn ADP LX 9 Color has 11 parameters (FSC, SCC, FL1-FL9) and is equipped with 488 nm, 635 nm, and 405 nm solid-state lasers. This model is ideal for up to 9-color analysis using a combination of FITC, PE, PE-Texas Red, PE-Cy5 or PER-CP, PE-Cy7, APC, APC-Cy7, fluorescent proteins, Pacific Blue and Cascade Yellow or other fluorochromes. Some key applications include stem cell/sp analysis, CD34 enumeration, signal transduction, antigen-specific T-cell detection, multicolor immunophenotyping and GFP-YFP FRET analysis. Code CyAn ADP Models Lasers Parameters Colors 488 nm 635 nm 405 nm CY200 30 CyAn ADP LX 7 Color, 9 Parameters, 110 V CY200 31 CyAn ADP LX 7 Color, 9 Parameters, 220 V 2 9 7 5 2 CY200 33 CyAn ADP LX 7 Color, 9 Parameters, 90 V CY201 30 CyAn ADP LX 9 Color, 11 Parameters, 110 V CY201 31 CyAn ADP LX 9 Color, 11 Parameters, 220 V 3 11 9 5 2 2 CY201 33 CyAn ADP LX 9 Color, 11 Parameters, 90 V

CyAn ADP Data Sheet Excitation lines 2 or 3 Lasers Optical parameters Maximal processing speed Sample flow rate Quartz cuvette Compensation Signal resolution 488 nm, 635 nm, 405 nm FSC, SSC and 7 or 9 fluorescence channels Up to 70,000 events per second Up to 150 µl/min (2.5 µl/sec) Fused silica with 250 µm square sectioned internal channel 9 x 9 matrix, auto compensation 4096 channels on all parameters Sensitivity MESF FITC < 100, MESF PE < 50 Beam geometry Sheath Management System Instrument footprint Instrument weight Noise level Elliptical/spherical Controls sheath, waste, and cleaning fluids Software, hardware and smart-sensor controls with RUN/PAUSE modes Continuous adjustable flow rate 30 cm wide x 45 cm deep x 40 cm high 11.8 inch wide x 17.7 inch deep x 15.7 inch high < 40 kg (88.2 lbs) < 70 db Software Summit Software version 4.3 Microsoft Office Professional Edition 2003 Operating system Microsoft Windows XP Professional For research use only. Not to be used in diagnostic procedures. 28212 04APR06 Denmark Corporate Headquarters Tel +45 44 85 95 00 United States of America Tel +1 805 566 6655 Distributors in more than 50 countries www.dako.com