INSTALLATION INSTRUCTIONS

Similar documents
INSTALLATION INSTRUCTIONS

LAN Installation Instructions. Converts John Deere Platform Heads with Reel Fore/Aft to Single Point Hydraulic & Electrical Connection

Sump Pump System OEM INSTALLATION MANUAL

Miniature I/P, E/P Transducer

important SAFETY instructions READ carefully, SAVE these instructions, DELIVER to owner after installation

Installation & Calibration

Power Distribution Module Replacement Instructions

OWNER S MANUAL. Model 845. RFV Dye Marking System /15

LAN84111 Installation Instructions

Installation Instructions

SECTION FIELD PANELS

Auxiliary Battery. In Compliance with: NMEDA Guidelines 6, FMVSS/CMVSS 305, SAE J1903. INSTALLATION MANUAL v2.4

INDeX Rack Installation Notes

Rough-in frame and flush-mount panel installation instructions

National Vendors Changetron 2/4 Validator Installation Instructions

TABLE OF CONTENTS. Vacuum Cleaner. Model No. MC-CG Bagless Canister Red North America

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES

Thank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions:

Urethane Booster Pump Seal Kit (Zenith or Nordson -Type)

1. Installation Preparatory work Equipotential bonding Floor installation Connection of several modules...

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

INSTALLATION MANUAL. FOOTWALL/SINKWALL (floor mount)

Aegis Heavy Capacity 20K Floor Scale. MODEL: 6200 Series. Installation Manual

Model Product Description and Specifications

LSA-PLUS Series 2. Connection and Disconnection Modules and Accessories. 1 st Edition

Installation Instructions

Model Product Description and Specifications

RoverBot Assembly. The following pages show assembly plans for the RoverBot using the Consumer MindStorms or School Team Challenge Lego kit.

H50. DYNAMIC BARRIER Bench Fume Hood. Fume Hoods. Installation Instructions. 48"- 60"- 72"- 96" long

Risk of fire and electrical shock. DISCONNECT POWER AT ELECTRICAL PANEL before installing or servicing this product.

PORTRAIT WARNING HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. 569 Ledge Front

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

FORM FOOTWALL. FORM FOOTWALL (floating) (floating) Installation Manual

Table of contents. 1. Introduction

A. Flat corner wall-to-wall See page 8. C. Outside corner wall-to-wall See page 8. B. Inside corner kit wall-to-wall See page 7

Installation & Calibration Manual

HydroCycle Vertical NFT Lettuce & Herb Systems

Revision 1 RAM ELEVATORS. Elevator Electrical Planning Guide. RAM Manufacturing Ltd

Installation Instructions. Overview. Important Notes. LINCTM Enclosure EDB-WPM-GRX-6-CE

FACTORY PARTS CATALOG MICROWAVE MICROWAVE FMT144GB FMB144GW FMT148GB FMT148GW FMT148GT FMT148GP FMT144GB FMB144GW FMT148GB FMT148GW FMT148GT FMT148GP

Q45WQ. Water Quality Monitoring System. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

OPERATION AND MAINTENANCE MANUAL

TECHNICAL SUPPORT MANUAL Fan Coils FSM2X, FSM4X

PC-PH SERIES BTUH

Install Guide D4B-IC2A-R-T-3 SERIES BRO I/C AIR TIGHT HOUSING

22.1 USED FOR: MATERIALS: all regular length 22 components stainless steel tool, silicon protective cover. DESCRIPTION

INSTALLATION MANUAL KOCH

RC7 Poke-Thru Series INSTALLATION INSTRUCTIONS Installation Instruction No.: R2 Updated April 2005

HydroLink Watering System with Snake Tubing Installation, Operation & Maintenance Manual

Operating Instructions

Cannon Trident Connector System

All MPO-IQ Boiler Repair Parts may be obtained through your local U.S. Boiler Company Wholesale distributor. Should you require assistance in

In-Wall Slide-out OEM INSTALLATION MANUAL

5485HT 5650H 5660H 5660HTS 5665HTS Instruction Kit Same Deutz-Fahr Flow Sensor 5SW models Flow Sensor 6SW models

Special Specification 6292 Radar Vehicle Detection System for Signalized Intersection Control

FORM HEADWALL. FORM HEADWALL (floating) (floating) Installation Manual

SYSTEM 600 BILL CHANGER INSTALLATION INSTRUCTIONS Congratulations...

H-Body Sealants Guide

Ceiling Camera Lift 2015

V21 Parts & Service Manual All V21 Identified Equipment REV A 10/2013 P/N: GENERAL INFORMATION. V21 General Information G-1

FORM HEADWALL. FORM HEADWALL (floor mount) (floor mount) Installation Manual

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS. 120V Permanent Magnet Drill STARTING SERIAL NUMBER.

Fun Industries Inc. G100D Grabber Deluxe Operation Instructions

axolute etèris Contents etèris

Installation Guide - Addendum Garmin to Contigo 6150

SERVICE PARTS LIST SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS. M18 FUEL 1-1/2" Linemen Magnetic Drill CATALOG NO. STARTING SERIAL NUMBER

2015 Code Rollout Meeting Q & A

INSTALLATION INSTRUCTIONS SUPERPLANE 4. Trim. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

White Paper. Disassembling the Performance Climate Changer Air Handler - Model UCCA CLCH-PRB044A-EN. Performance UCCA Air Handler Disassembly

Agilent 1260 Infinity RID User Manual. 9 Maintenance

SERVICE PARTS LIST BULLETIN NO M18 FUEL 1-1/2" Magnetic Drill CATALOG NO. G96A

General Safety Information

VertiGreen Modular Living Wall System Installation Instructions (VGM-06 and VGM-10 Wall Mount)

Thermatile Ten-Twelve Radiant Panels. Installation instructions

INSTALLATION INSTRUCTIONS FOR McDONALDS LED CANOPY FASCIA. Table of Contents

Fyrite. Tech Model 50 & 60 Combustion Gas Analyzer. Instruction Operation & Maintenance Rev. 4 August 2005

TDN Dec B St. Long Beach, MS Phone: (228) Fax: (228)

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Hydro-wind Education Kit ASSEMBLY GUIDE

ELECTRICAL SAFETY Information Bulletin

EXIRA EXPOSED PIPE SHOWER INSTALLATION

DO NOT INSTALL, OPERATE OR SERVICE PRODUCT WITHOUT HAVING READ AND FULLY UNDERSTAND ALL SAFETY PROCEDURES, WARNINGS, INSTALLATION AND OPERATING

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

ISIMET. E Series Enclosure. Custom Assemblies Installation, Maintenance, and Operation Instructions

HDI 2200 Choke Position Indicator

Power Supply Featuring OMRON s Unique, New Undervoltage Alarm Function with Compact Body Contributing to Machine Downsizing

SUBJECT ADTC TO U11 CONTROLLER FIELD RETROFIT

REPTILE 66-4 FREEDOM BREEDER

FFTR1821QB6A FFTR1821QM6A FFTR1821QS6A FFTR1821QW6A

min. 50min. 65min. PIT / P3 / P4 Ø

All panels can be supplied in a range of styles, to suit the applications pictured below.

Installation Instructions

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

Application & General Notes: Installation Supplements: Safety Warning: Other Installation References: Receiving & Handling: Electrical Guidelines:

WARNINGS AND PRECAUTIONS

H07 H09. BENCH FUME HOOD with Combination Sash. Fume Hoods. Installation Instructions. 48"- 60"- 72"- 96" long

Section 8 Technician Level Maintenance

Replacing the Billboard UPS

DYNATHERM Boiler Mfg. 43 E Cherry Rd Quakertown PA (215) Fax: (215) PN# /12 REV.

ASSEMBLY & INSTALLATION INSTRUCTIONS

Transcription:

INSTALLATION WARNING: BEFORE INSTALLING READ ALL OF THE MANUFACTURERS INSTALLATION AND MAINTENANCE NOTE: This Ac ces sory can not be ap plied to the 25 Ton (D*CE/CG300 and DUC/DHB300), which util ize the H705 Honeywell Economizer Controller. MODEL # 2AQ04700424 Step 1: Check for the correct number of parts for model 2AQ04700424. See list below: 1 ea CO 2 Sensor 1 ea CO 2 Sensor Base 1 ea Pitot Tube Kit (tubing to be cut to length for each application) 1 ea CO 2 Sensor Bracket for 3-6 ton 1 ea CO 2 Sensor Bracket for 7-25 ton 1 ea 0-10 VDC Potentiometer Signal Converter (Honeywell Q769C) 1 ea CO 2 Sensor "Splice" Wiring Harness (W7212 Economizer Control) 4 ea 8 x ½" PAN/PHIL Screws 2 ea 8 x ¾" PAN/PHIL Screws 1 ea 4" Violet Wire 1 ea 4" Red Wire 1 ea 8" Violet Wire 1 ea 8" Red Wire 1 ea 10' Brown Wire 1 ea 10' Red Wire 8 ea. Wire Ties 1 ea. 7 8 " x ½" Snap Bushing 2 ea #10-16 x ½ HexTex Screws 15-25 TON BRACKET 3-6 TON BRACKET HONEYWELL Q769C SPLICE HARNESS W7212 CO 2 SENSOR AND BASE PITOT TUBE KIT

INSTALLATION Step 2: Determine in which unit the CO 2 sensor is to be installed: The following is for units with economizers. 6.5-12.5 Ton Predator Units 3-6 Ton Sunline Units 15 - *25 Ton Sunline Units For 6.5-12.5 Ton Predator Units PITOT TUBE Step 3: Mount pitot tube in side of damper frame in prepunched holes. DAMPER FRAME Step 4: Attach clear hose to the pitot tube. Make sure the In-line filter is connected to "H" on the pitot tube. Step 5: Mount CO 2 sensor base in place on the economizer using two 8 X ½" PAN/PHIL screws provided. Step 6: If the unit has a W7459 Economizer Control, install the Honeywell Q769C potentiometer signal converter, if not skip to Step 8. ECONOMIZER LOGIC CONTROL CO 2 SENSOR BASE Step 7: Make sure to secure the Q769C device using the included wire ties. Route the wires (raw end) through the square holes in the mounting bracket. Then disconnect the (P-P1) jumper from the economizer control located on the actuator and connect the Q769C per wiring Diagram # 80CO201. Step 8: If a W7212 Economizer Control is used, wire per Diagram # 80C0202. Q769C

INSTALLATION Step 9: Mount CO 2 sensor on CO 2 sensor base. Step 10: Connect clear hoses to CO 2 sensor. For W7459 Economizer Controller applications Step 11: Power the CO 2 device via a properly protected, field supplied, non-grounded transformer of the appropriate primary and secondary voltage per the attached Diagram # 80CO201. Program the CO 2 sensor per the HOSES For W7212 Economizer Controller applications Step 11: Use supplied "Splice" harness to obtain power; See Diagram # 80C0202. Program the CO 2 sensor per the PITOT TUBE IN-LINE FILTER

INSTALLATION For 3-6 Ton Sunline Units Step 3: Mount the pitot tube assembly in the bracket taking care to orient the pitot tube in the direction of airflow indicated by the arrow on the pitot tube. The direction of airflow will be determined by whether the unit is configured in a downflow application or a sideflow Place the probe through the 7 8" hole in the bracket and secure with the two 8 x ½" screws provided. Step 4: Mount the CO 2 sensor base on the bracket using two 8 x ½" screws provided. Step 5: Attach the clear hose to the pitot tube. Make sure the in-line filter hose is connected to "H" on the pitot tube. Step 6: Mount the CO 2 sensor on the CO 2 base and connect the clear hoses to the CO 2 sensor ports. Orientation of the hoses is not critical as either hose can be connected to either port. Step 7: Locate the return air access panel and the two screws located in the lower corner. One screw secures an insulation retainer (discard the retainer) and the other secures the unit base to the base rail. Retain these screws for later use. Step 8: Remove the two screws mentioned above and insert the bracket, with the devices premounted, using the screws previously removed. Step 9: Trim the clear hose so that it easily reaches between the probe and the base making sure to allow for sufficient space for the in-line filter.

INSTALLATION Step 10: The finished installation should then appear as shown in the picture. For W7459 Economizer Controller applications Step 11: Install the Honeywell Q769C potentiometer signal converter Step 12: Make sure to secure the Q769C device using the included wire ties. Route the wires (raw end) through the square holes in the mounting bracket. Then disconnect the (P-P1) jumper from the economizer control located on the actuator and connect the Q769C per wiring Diagram # 80CO201. Step 13: Power the CO 2 device via a properly protected, field supplied, non-grounded transformer of the appropriate primary and secondary voltage per the attached Diagram # 80CO201. Program the CO 2 sensor per the For W7212 Economizer Controller applications HONEYWELL Q769C Step 11: Wire per Diagram# 80C0202. Step 12: Use supplied "Splice" harness to obtain power; See Diagram # 80C0202. Program the CO 2 sensor per the

INSTALLATION For 15-25 Ton Sunline Units: Step 3: Mount the 15-25 ton bracket by screwing bracket to economizer (with drill screws provided). The bracket should be 3.0" down from top edge of economizer frame, and flush with the inside edge of frame. TYPICAL ECONOMIZER f HOLE FOR SNAP BUSHING Step 4: Drill a 7 8" hole, 6.0" in from the top outside corner of the economizer, between the economizer and the Wiring harness. TOP EDGE INSIDE EDGE Step 5: Install snap bushing (provided). (Heyco P/N SB 875-8, or equivalent.) TYPICAL PARTITION PANEL

INSTALLATION Step 6: Drill a 7 8" hole, 15.0" in and 9 1 8" up from the lower left corner of the economizer partition panel. Step 7: Drill one 1 8" hole at 15.0" in and 7 ¾" up from the lower left corner of the economizer partition panel. TWO 1 8 HOLES Step 8: Drill one 1 8" hole at 15.0" in and 10 ½" up from the lower left corner of the economizer partition panel. 7 8 HOLE Step 9: Drill one 1 8" hole at 13 5 8" in and 9 1 8" up from the lower left corner of the economizer partition panel. Step 10: Drill one 1 8" hole at 16 3 8" in and 9 1 8" up from the lower left corner of the economizer partition panel. Step 11: Mount the pitot tube assembly in the Economizer Partition Panel taking care to orient the pitot tube in the direction of airflow. The arrow on the pitot tube indicates this. The direction of airflow will be determined by whether the unit is configured in a down flow application or a side flow Place the probe through the 7 8" hole in the Partition Panel and secure with the two 8 x ¾" Pan/Phil screws (provided). Step 12: Attach the clear hose to the pitot tube. Make sure the in-line filter hose is connected to "H" on the pitot tube. Step 13: Route tubing through wire ties as needed to prevent tubes being pinched. Step 14: Mount the CO 2 sensor base on the bracket using 8 x ½" screws provided. Step 15: Mount the CO 2 sensor on the CO 2 base and connect the clear hoses to the CO 2 sensor ports. Orientation of the hoses is not critical as either hose can be connected to either port. POWER EXHAUST FAN REMOVED FOR ILLUSTRATIVE PURPOSES ONLY

INSTALLATION For W7459 Economizer Controller applications Step 16: If the Unit has a W7459 Economizer Control, install the Honeywell Q769C potentiometer signal converter, if not skip to Step 16. Step 17: Make sure to secure the Q769C device using the included wire ties. Then disconnect the (P-P1) jumper from the economizer control located on the actuator and connect the Q769C per wiring Diagram # 80CO201. Step 18: Power the CO 2 device via a properly protected, field supplied, non-grounded transformer of the appropriate primary and secondary voltage per the attached diagram # 80CO201. Program the CO 2 sensor per the SNAP BUSHING NEEDED For W7212 Economizer Controller applications Step 16: Wire per Diagram # 80C0202. Step 17: Use supplied "Splice" harness to obtain power; See Diagram # 80C0202. Program the CO 2 sensor per the HONEYWELL Q769C

INSTALLATION Step 2: Determine in which unit the CO 2 sensor is to be installed: The following is for units with return air and no economizer. 6.5-12.5 Ton Predator Units 3-6 Ton Sunline Units 15 - *25 Ton Sunline Units PROBE CO 2 SENSOR BASE Note: 6.5-12.5 Ton Predator Units is shown. Lo ca tion over re turn will be the same for all units. Step 3: Mount the pitot tube on the bracket. Placing probe through 7 8" hole and secure with two 8 x ½ screws provided. PITOT TUBE IN-LINE FILTER Step 4: Mount CO 2 sensor base on the bracket using one 8 x ½ screws to secure. Step 5: Attach clear hose to the pitot tube. Make sure the In-line filter hose is connected to "H" on the pitot tube. Step 6: Mount CO 2 sensor on CO 2 sensor base and connect clear hoses to CO 2 sensor. MOUNTING HOLE Step 7: Then route wire and Q769C to unit electrical panel and make wire connections. Step 8: Remove screw from unit base and place CO 2 sensor assembly in place and secure with screw that is removed. SUPERCEDES 09-11-02 OCTOBER 10, 2002 UNIT BASE 035-19231-000-A-1002 FORM# YKICO202

W7459 - Economizer Logic Module P# - Plug Connector S# - Socket Connector Transformer must not be grounded Note: The socket and plug numbers change per unit. Date: October 10, 2002 Supercedes: Diagram# 80CO201

SPLICE HARNESS Note: The socket and plug numbers change per unit. SDRA - Smoke Detector, Return Air W7212 - Economizer Logic Module P# - Plug Connector S# - Socket Connector Jumper Located on T-stat Interface Board Date: October 10, 2002 Supercedes: 09-11-02 Diagram# 80CO202