HDPE PERFORATION GUIDE PERFORATIONS PER AASHTO M252/M294

Similar documents
HDPE PRODUCTS QUALITY, PERFORMANCE AND ECONOMY COMBINED

SINGLE-WALL DRAINAGE PIPE (SWP) TECHNICAL DATA

Standard Specification for Corrugated Steel Pipe, Metallic-Coated for Sewers and Drains 1

A. This section includes the furnishing and installation of a foundation drainage system.

GEOGRID CONNECTION DETAIL OLYMPIA RADIUS UNIT

SECTION SUBDRAINAGE

ITEM 461 STRUCTURAL PLATE STRUCTURES. Galvanized steel plates shall conform to AASHTO M167 and aluminum plates shall conform to AASHTO M219.

JIS G3446 Stainless steel pipes for machine and structural purposes

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CHAPTER 2. Restricted Residential ½ Street** Design Speed 25 MPH 25 MPH 25 MPH 25 MPH 40 MPH 50 MPH 55 MPH

ITEM D-701 PIPE FOR STORM DRAINS AND CULVERTS

Item 460 Corrugated Metal Pipe

Pre-Audit Application Form

LANE ENTERPRISES, INC. STANDARDS & SPECIFICATIONS

SECTION UNDERDRAINS. 1. Protection of the environment; Section Trench excavation, backfill, and compaction; Section

Appendix J: Storm Conveyance Design Parameters

50.20 Drainage Structure Design

Testing. Test drainage products according to the applicable AASHTO or ASTM specification, except as otherwise noted.

Audit Report. AASHTO s National Transportation Product Evaluation Program (NTPEP) Evaluation of Name and Location. Plant Name: Physical Address:

Commonwealth of Pennsylvania PA Test Method No. 614 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

GEO-flow Pipe Leaching System Specifications & Features. Design & Installation Manual Maine

BIG 'O' HDPE Tubing CORRUGATED TUBING FOR AGRICULTURAL, RESIDENTIAL AND HIGHWAY DRAINAGE. Proudly owned and operated in Canada. aquaq.

CW 3120 INSTALLATION OF SUBDRAINS TABLE OF CONTENTS

HDPE corrugated double wall pipes

SECTION STORM SEWER COLLECTION SYSTEM

BMP 6.4.4: Infiltration Trench

PRECONSTRUCTION DESIGN MEMORANDUM CULVERT PIPE STRUCTURAL DESIGN CRITERIA FOR SCDOT FILL HEIGHT TABLES

GENERAL NOTES ROADWAY CONSTRUCTION RD0001-1A ISSUED:2017 REVISED: --

ADS SPECIFICATIONS TABLE OF CONTENTS

BIG O HDPE TUBING HDPE CORRUGATED TUBING FOR AGRICULTURAL, RESIDENTIAL AND HIGHWAY DRAINAGE INCREASE CROP YIELDS LOWER PRODUCTION COSTS

Baseline Document Change Announcement

SECTION STORM DRAINAGE

Evaluation of Polypropylene Drainage Pipe Manufacturers

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Evaluation of HDPE (High Density. Drainage Pipe Manufacturers. Polyethylene) Thermoplastic. NTPEP Committee Work Plan for

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

Section 7 Roadway GENERAL REQUIREMENTS I. TYPICAL SECTION...7-1

Special Provision for LRFD Pipe Culvert Burial Tables

Chapter 10. Conduit Outlet Structures Introduction General Layout Information

DEPARTMENT OF TRANSPORTATION STATE OF GEORGIA SPECIAL PROVISION. Section 550 Storm Drain Pipe, Pipe-Arch Culverts, and Side Drain Pipe

EPA Method 1 Field Procedures Example:

March, 2017 Nova Scotia On-site Sewage Disposal Systems Standard revisions effective May 1, Appendix C Falling head permeameter

STANDARD SPECIFICATIONS SECTION 16 STORM SEWER SYSTEMS

FOR HISTORICAL REFERENCE ONLY

PRODUCT SPECIFICATION

Lesson 7 REINFORCING CAGE. Version 1-1/

NOTES ON CORRUGATED PLASTIC PIPE SUBSOIL DRAIN CONSTRUCTION SPECIFICATION

Stake-Lok. SOLID Corrugated AluminumAlloy. Culvert Pipe

SECTION 300 STORM SEWER TABLE OF CONTENTS

TECHNICAL NOTE HDPE Pipe and Utility Crossings

TOWN OF LAFAYETTE SPECIFICATIONS FOR HIGHWAY CONSTRUCTION. June 1984

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 9/17/18)

The Most Advanced Name in Water Management Solutions TM. The most cost-effective slotted and trench surface drain systems.

MagnumStone Specifications Gravity

All Regional Engineers. Omer M. Osman, P.E. Special Provision for LRFD Pipe Culvert Burial Tables. July 25, 2014

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 5/8/7)

Model Number. Job Number. StormChamber. Installation with liner for Retention Manual.

SECTION STORM DRAINAGE SYSTEM Excavating, Backfilling, and Compaction for Utilities Cast-in-place Concrete.

4.8. Subsurface Infiltration

GWINNETT COUNTY STORM SEWER PIPE STANDARDS

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CUYAHOGA COUNTY ENGINEER

***************************************************************************************************************

Introduction to Storm Sewer Design

SPECIFICATION FOR CORNERSTONE GEOGRID REINFORCED SEGMENTAL RETAINING WALL SYSTEM

Base Course Design and Construction

Geotextile Sand Filter

PRODUCT SPECIFICATION CSI FORMAT Slope and Channel Grid Systems April 2009

Construction Inspection Checklists

SECTION 303 CULVERTS

A-2000 PVC Pipe for Storm Sewers and Drainage

Handling and Installation Instructions

StormTech Construction Guide An company

PIPING SOLUTIONS Drainage HDPE ID DRAINAGE PIPES

SECTION STORM DRAINAGE DESIGN, GRADING, AND WATER QUALITY TECHNICAL CRITERIA TABLE OF CONTENTS PAGE 402 STORM DRAINAGE DESIGN CRITERIA 400-1

StormTech Construction Guide

TUNNEL LINER PLATE INTRODUCTION GENERAL APPLICATIONS CHAPTER 11

1. Division 01 Section General Requirements - Temporary Facilities and Controls. 2. Division 31 Section Earthwork.

Chapter 11 Culverts and Bridges

Appendix B: Green Infrastructure Typical Details and Specifications

PIPING SOLUTIONS Drainage HDPE OD DRAINAGE PIPES

SECTION STORM DRAINAGE AND STORMWATER MANAGEMENT

SECTION 14 EMBANKMENT

Appendix B.2. Construction Specifications for Infiltration Practices

Golder Associates Inc W. Laburnum Avenue, Suite 200 Richmond, VA USA Tel: (804) Fax: (804)

Hancor, Inc. Drainage Handbook Hydraulics 3-1

SECTION STORM DRAINAGE UTILITIES. B. Section : Site Restoration and Rehabilitation

105 - Control of Material

PRODUCT SPECIFICATION CSI FORMAT Earth Retention System April 2009

MC-3500 & MC-4500 Design Manual StormTech Chamber Systems for Stormwater Management

SECTION BORING AND/OR JACKING PIPE

NATIONAL CORRUGATED STEEL PIPE ASSOCIATION

SENSE Level I Welding Process Certification Test Module 3: Drawing and Welding Symbol Interpretation

CITY UTILITIES DESIGN STANDARDS MANUAL

GRAVITY SEGMENTAL RETAINING WALL

C231 Subsoil and Foundation Drains

Wastewater Capital Projects Management Standard Construction Specification

HYDROLOGIC RESTORATION OF THE CASH CREEK BASIN IN TATE'S HELL STATE FOREST

4.8. Subsurface Infiltration

Transcription:

PERFORATIONS GENERAL Lane s perforated pipe offerings follow the AASHTO classification system and conform to AASHTO requirements for size, spacing and placement of the perforations. It is not the intent of this guide to cite AASHTO requirements but to describe Lane s perforated pipe offerings with the added note that AASHTO specifications are met. CLASS 1 PERFORATIONS (PARTIALLY PERFORATED PIPE) Class 1 perforations are for pipe intended to be used for subsurface drainage or combination storm and underdrain. As such, the pipe maintains an unperforated segment above the invert to serve as a flow channel. Perforations are circular and arranged in rows parallel to the axis of the pipe with one perforation in each row for each corrugation. Rows of perforations are arranged in two equal groups placed symmetrically on each side of a lower unperforated segment corresponding to the flow line of the pipe. CLASS 2 PERFORATIONS (STANDARD OR FULLY PERFORATED PIPE) Class 2 perforations are for pipe intended to be used for subsurface drainage only. Perforations may be circular or slotted and are uniformly spaced along the length and circumference of the pipe. Perforated pipe shall conform to the requirements for Class 2 unless noted otherwise. AASHTO M252 CLASS 2 SLOTTED PERFORATIONS FOR SINGLE WALL (CP) AND DOUBLE WALL (SP) PIPE Type CP Class 2 Slotted Perforations D P n l w WIA 4 0.645 4 0.783 0.069 4.02 6 0.824 4 0.769 0.055 2.46 8 1.02 4 0.759 0.050 1.79 Type SP Class 2 Slotted Perforations D P n l w WIA 6 0.773 4 0.769 0.055 2.63 8 0.975 4 0.759 0.050 1.87 10 1.525 4 0.779 0.054 1.32 P = Period of Corrugations (in) n = number of slots per corrugation valley l = average length of slotted perforation (in) w = average width of slotted perforation (in) Class 2 slotted perforations includes a total of four equally spaced slots in each corrugation valley as shown by the black centerlines at right. PG 1

AASHTO M294 CLASS 2 SLOTTED PERFORATIONS FOR DOUBLE WALL (SP) PIPE Type SP Class 2 Perforations D d L WIA 12 0.3125 1.94 2.85 15 0.3125 2.62 2.11 18 0.3125 2.96 1.87 L = Longitudinal spacing between holes (in) Class 2 perforations for 12", 15" and 18" HDPE pipes include a total of six equally spaced 5/16" diameter holes in each corrugation valley as shown at right. Type SP Class 2 Perforations D d L WIA 24 0.3750 3.95 2.68 30 0.3750 4.01 2.64 36 0.3750 4.06 2.61 42 0.3750 5.38 1.97 48 0.3750 5.37 1.97 L = Longitudinal spacing between holes (in) Class 2 perforations for 24", 30", 36", 42" and 48" HDPE pipes include a total of eight equally spaced 3/8" diameter holes in each corrugation valley as shown at right. PG 2

AASHTO M252 CLASS 1 PERFORATIONS FOR DOUBLE WALL (SP) PIPE AASHTO M252 Type SP Class 1 Perforations (6" through 10") D 1 2 L L min H H max s 1/2 d S WIA 6 48 70 4.46 3.74 1.97 2.76 1.15 0.1875 0.75 1.77 8 48 70 5.95 5.12 2.63 3.70 1.54 0.1875 1.00 1.33 10 48 70 7.43 6.30 3.29 4.72 1.92 0.3125 1.75 2.10 1 37.5, 2 85 (AASHTO maximum and minimum angles) s = arc length between holes (in) Class 1 perforations for 6", 8" and 10" HDPE pipes include a total of four holes in each corrugation valley as shown below. Perforations for the 6" and 8" pipes shall be 3/16" diameter, while the perforations for the 10" pipe shall be 5/16" diameter. PG 3

AASHTO M294 CLASS 1 PERFORATIONS FOR DOUBLE WALL (SP) PIPE AASHTO M294 Type SP Class 1 Perforations (12" through 18") D 1 2 3 L L min H H max s 1/2 s 2/3 d S WIA 12 47 62 78 8.78 7.56 4.75 5.43 1.57 1.68 0.38 1.94 4.10 15 47 62 78 10.97 9.45 5.94 6.77 1.96 2.09 0.38 2.62 3.04 18 47 62 78 13.16 11.34 7.13 8.15 2.36 2.51 0.38 2.96 2.69 1 40, 3 85 (AASHTO maximum and minimum angles) s = arc length between holes (in), must be 1 inch Class 1 perforations for 12 through 18 in HDPE pipes include a total of six ⅜" diameter holes in each corrugation valley as shown below. PG 4

AASHTO M294 CLASS 1 PERFORATIONS FOR DOUBLE WALL (SP) PIPE AASHTO M294 Type SP Class 1 Perforations (24" through 48") D 1 2 3 4 L L min H H max s 1/2 s 2/3 s 3/4 d S WIA 24 46 57 68 79 17.26 15.36 9.71 11.04 2.30 2.30 2.30 0.375 3.95 2.68 30 46 57 68 79 21.58 19.20 12.14 13.80 2.88 2.88 2.88 0.375 4.01 2.64 36 46 57 68 79 25.90 23.04 14.57 16.56 3.46 3.46 3.46 0.375 4.06 2.61 42 46 57 68 79 30.21 26.88 16.99 19.32 4.03 4.03 4.03 0.375 5.38 1.97 48 46 57 68 79 34.53 30.72 19.42 22.08 4.61 4.61 4.61 0.375 5.37 1.97 Class 1 perforations for 24 through 48 in HDPE pipes include a total of eight ⅜" diameter holes in each corrugation valley as shown below. 1 40, 4 85 (AASHTO maximum and minimum angles) s = arc length between holes (in), must be 1 inch PG 5