Evaluation of the ASCE 7-05 Standard for Dual Systems: Response History Analysis of a Tall Buckling-Restrained Braced Frame Dual System

Similar documents
COMPARATIVE PERFORMANCE OF BUCKLING-RESTRAINED BRACES AND MOMENT FRAMES

Seismic Performance and Design of Linked Column Frame System (LCF)

Effect of Standard No Rules for Moment Resisting Frames on the Elastic and Inelastic Behavior of Dual Steel Systems

HYBRID MOMENT RESISTING STEEL FRAMES

EFFECTS OF COLUMN CAPACITY ON THE SEISMIC BEHAVIOR OF MID-RISE STRONG-COLUMN-WEAK-BEAM MOMENT FRAMES

SEISMIC VULNERABILITY ASSESSMENT OF STEEL PIPE SUPPORT STRUCTURES

REINFORCED CONCRETE WALL BOUNDARY ELEMENT LONGITUDINAL REINFORCING TERMINATION

IMPROVING SEISMIC PERFORMANCE: ADD STIFFNESS OR DAMPING? Trevor E. Kelly 1

Seismic evaluation of Hybrid steel frames with different patterns of semi-rigid connection

EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS

Evaluation of Seismic Behavior of Buckling Restrained Braced Frames as Dual System in Combination with Special Moment Resisting Frames

SYSTEM PERFORMANCE OF STEEL MOMENT RESISTING FRAME STRUCTURES

Response of TBI case study buildings

Title. Author(s)ARDESHIR DEYLAMI; MOSTAFA FEGHHI. Issue Date Doc URL. Type. Note. File Information IRREGULARITY IN HEIGHT

The Effect of Frame Geometry on the Seismic Response of Self-Centering Concentrically- Braced Frames

DESIGN ASPECTS AFFECTING THE SEISMIC BEHAVIOUR OF STEEL MRF BUILDINGS: ANALYSIS OF THREE CASE STUDIES

EVALUATION OF SEISMIC PERFORMANCE FACTORS FOR CHEVRON BUCKLING RESTRAINED BRACED FRAMES

COMPARISON OF LOW-RISE STEEL CHEVRON AND SUSPENDED ZIPPER BRACED FRAMES

STRENGTH REDUCTION FACTORS FOR MULTI-DEGREE-OF-FREEDOM SYSTEMS

LIGHTLY DAMPED MOMENT RESISTING STEEL FRAMES

ctbuh.org/papers CTBUH Recommendations for the Seismic Design of High-Rise Buildings

INFLUENCE OF DIFFERENT TYPES OF FULLY RESTRAINED CONNECTIONS ON THE RESPONSE OF SMRF STRUCTURES

EVALUATION OF DESIGN METHODOLOGIES FOR STRUCTURES INCORPORATING STEEL UNBONDED BRACES FOR ENERGY DISSIPATION

PUSHOVER ANALYSIS OF A 19 STORY CONCRETE SHEAR WALL BUILDING

PERFORMANCE-BASED PLASTIC DESIGN AND ENERGY-BASED EVALUATION OF SEISMIC RESISTANT RC MOMENT FRAME

A Comparison of Seismic Performance and Vulnerability of Buckling Restrained and Conventional Steel Braced Frames

Span Length Effect on Seismic Demand on Column Splices in Steel Moment Resisting Frames

The Influence of Gravity-Only Framing on the Performance of Steel Moment Frames

Inelastic Torsional Response of Steel Concentrically Braced Frames

MODAL AND CYCLIC PUSHOVER ANALYSIS FOR SEISMIC PERFORMANCE EVALUATION OF BUCKLING-RESTRAINED BRACED STEEL FRAME

NON LINEAR STATIC ANALYSIS OF DUAL RC FRAME STRUCTURE

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

EVALUATION OF ANALYSIS PROCEDURES FOR PERFORMANCE-BASED SEISMIC DESIGN OF BUILDINGS

Innovative Moment Resisting Frame System for Earthquake

DEFLECTION AMPLIFICATION FACTORS FOR DUCTILE BRACED FRAMES

Comparison of Chevron and Suspended Zipper Braced Steel Frames

Performance-Based Plastic Design (PBPD) of High-Rise Buckling-Restrained Braced Frames

STRUCTURAL DESIGN REQUIREMENTS (SEISMIC PROVISIONS) FOR EXISTING BUILDING CONVERTED TO JOINT LIVING AND WORK QUARTERS

3. Analysis Procedures

MCEER Hospital Demonstration Project

SEISMIC PERFORMANCE OF CONCRETE TILT-UP BUILDINGS: CURRENT WALL-TO-SLAB CONNECTIONS

GUIDELINES ON NONLINEAR DYNAMIC ANALYSIS FOR SEISMIC DESIGN OF STEEL MOMENT FRAMES

Linear and Nonlinear Seismic Analysis of a Tall Air Traffic Control (ATC) Tower

Design check of BRBF system according to Eurocode 8 Use of pushover analysis

Seismic Performance of Residential Buildings with Staggered Walls

Assessment of Response Modification Factor of Open Steel Platform Structures Subjected to Seismic Loads

Seismic performance assessment of reinforced concrete buildings using pushover analysis

Comparison between Seismic Behavior of Suspended Zipper Braced Frames and Various EBF Systems

NONLINEAR PERFORMANCE OF A TEN-STORY REINFORCED CONCRETE SPECIAL MOMENT RESISTING FRAME (SMRF)

Determination of Acceptable Structural Irregularity Limits for the Use of Simplified Seismic Design Methods

ctbuh.org/papers Seismic Performance of High-Rise Intermediate Steel Moment Frames Title:

Finite Element Model Calibration of An Instrumented Thirteen-story Steel Moment Frame Building in South San Fernando Valley, California

Seismic Evaluation of Steel Moment Resisting Frame Buildings with Different Hysteresis and Stiffness Models

APPLICATION OF ENERGY DISSIPATION TECHNOLOGY FOR RETROFITTING STEEL STRUCTURES WITH VULNERABLE PRE- NORTHRIDGE CONNECTIONS

SEISMIC EVALUATION AND RETROFIT OF A HOSPITAL BUILDING USING NONLINEAR STATIC PROCEDURE IN ACCORDANCE WITH ASCE/SEI 41-06

Seismic Performance Evaluation of an Existing Precast Concrete Shear Wall Building

SEISMIC SIMULATION OF AN EXISTING STEEL MOMENT-FRAME BUILDING RETROFITTED WITH EXTERNAL CABLE-STAYED SYSTEM

INTERACTION OF TORSION AND P-DELTA EFFECTS IN TALL BUILDINGS

Concept of Earthquake Resistant Design

Modeling of steel moment frames for seismic loads

RELIABILITY OF NONLINEAR STATIC METHODS FOR THE SEISMIC PERFORMANCE PREDICTION OF STEEL FRAME BUILDINGS

DISPLACEMENT-BASED SEISMIC ASSESSMENT OF EXISTING NON- DUCTILE STEEL CONCENTRICALLY BRACED FRAMES

SEISMIC PERFORMANCE EVALUATION

ANALYSIS PROCEDURES FOR PERFORMANCED BASED DESIGN

Steel moment frames have been one of the most frequently

Engr. Thaung Htut Aung M. Eng. Asian Institute of Technology Deputy Project Director, AIT Consulting

Improving the Seismic Response of a Reinforced Concrete Building Using Buckling Restrained Braces

EFFECTS OF STRONG-MOTION DURATION ON THE RESPONSE OF REINFORCED CONCRETE FRAME BUILDINGS ABSTRACT

DUAL SYSTEM DESIGN OF STEEL FRAMES INCORPORATING BUCKLING-RESTRAINED BRACES

CASE STUDY OF A 40 STORY BRBF BUILDING LOCATED IN LOS ANEGELES

Engineering Structures. Performance-based plastic design method for buckling-restrained braced frames

CONTRIBUTION of GRAVITY FRAMES TO SEISMIC PERFORMANCE OF STEEL MOMENT RESISTING FRAMES

Design Example 2 Reinforced Concrete Wall with Coupling Beams

EFFECTS OF POST-YIELD STIFFENING AND STRENGTHENING ON THE COLLAPSE PERFORMANCE OF NON- BUCKLING BRACED FRAMES

COMPARATIVE SEISMIC PERFORMANCE OF RC FRAME BUILDINGS DESIGNED FOR ASCE 7 AND IS 1893

Evaluation of Response Reduction Factor and Ductility Factor of RC Braced Frame

The International Conference on Earthquake Engineering and Seismology. Naveed Anwar. ICEES April 2011 NUST, Islamabad Pakistan

SEISMIC PERFORMANCE OF STEEL MOMENT RESISTING FRAMES DESIGNED WITH: DISPLACEMENT-BASED AND STRENGTH-BASED APPROACHES

Damage Concentration in Multi-Story Buckling Restrained Braced Frame (BRBF) Relations with participant ratioβof BRB-

Performance-Based Seismic Evaluation of Wind-Impacted Tall Buildings

EXPERIMENTAL VALIDATION OF THE STRUCTURAL FUSE CONCEPT

DESIGN OF HIGH-RISE CORE-WALL BUILDINGS: A CANADIAN PERSPECTIVE

Alternative Methods of Evaluating and Achieving Progressive Collapse Resistance

INVESTIGATION ON NONLINEAR ANALYSIS OF EXISTING BUILDING AND INTRODUCING SEISMIC RETROFITTING OUTLINES WITH CASE STUDY

ctbuh.org/papers Proposed Methodology To Determine Seismic Performance Factors For Steel Diagrid Framed Systems

Design Procedures for Buildings Incorporating Hysteretic Damping Devices

International Journal of Engineering and Techniques - Volume 4 Issue 2, Mar Apr 2018

Innovative Building Lateral System with Strongback Frames and Mechanical Fuses

PEER/CSSC Tall Building Design Case Study Building #1. J. Andrew Fry John Hooper Ron Klemencic Magnusson Klemencic Associates

SEISMIC STABILITY OF BUCKLING-RESTRAINED BRACED FRAMES SANTIAGO RAUL ZARUMA OCHOA THESIS

Index terms Diagrid, Nonlinear Static Analysis, SAP 2000.

EVALUATION OF MODAL PUSHOVER ANALYSIS USING VERTICALLY IRREGULAR FRAMES

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

SEISMIC DAMAGE CONTROL WITH PASSIVE ENERGY DEVICES: A CASE STUDY

Seismic performance of dual frames with composite CF-RHS high strength steel columns

Displacement-Based Seismic Analysis of A Mixed Structural System

Modeling of Shear Walls for Nonlinear and Pushover Analysis of Tall Buildings

Title. Author(s)A.DAYLAMI; M.A.MAHDAVIPOUR. Issue Date Doc URL. Type. Note. File Information DEMAND.

STUDY OF SEISMIC BEHAVIOR OF SCBF WITH BALANCED BRACING

STRUCTURAL CALCULATIONS SEISMIC EVALUATION PEER REVIEW

Transcription:

Evaluation of the ASCE 7-5 Standard for Dual Systems: Response History Analysis of a Tall Buckling-Restrained Braced Frame Dual System L. J. Aukeman 1 and P. Laursen 1 Graduate Student, Department of Architectural Engineering, California Polytechnic University, San Luis Obispo; email: laukeman@calpoly.edu Assistant Professor, Department of Architectural Engineering, California Polytechnic University, San Luis Obispo, 1 Grand Ave. San Luis Obispo, CA 937; PH (5) 75-131; email: plaursen@calpoly.edu ABSTRACT In mid-to-high rise structures, dual systems (DS) enable a structural designer to satisfy the stringent drift limitations of current codes without compromising ductility. Currently, ASCE 7-5 permits a variety of structural systems to be used in combination as a dual system yet the design requirements are limited to the following: Moment frames must be capable of resisting 5% of the seismic forces while the moment frames and braced frames or shear walls must be capable of resisting the entire seismic forces in proportion to their relative rigidities. This paper assesses the significance of the 5% design requirement for the secondary moment frames (SMF) in dual systems with consideration of current structural engineering practice. Three -story buckling-restrained braced frame (BRBF) dual system structures have been designed with varying relative strengths between the braced and special moment frame systems. The SMF system has been designed for 15%, 5%, and % of seismic demands and the BRBF system design has been adjusted accordingly based on its relative stiffness with respect to the moment frame. These structures have been examined with nonlinear static and nonlinear dynamic procedures with guidance from ASCE 1-. The drift, displacement and ductility demands, and the base shear distribution results of this study show similar responses of the three prototype structures. These results indicate a secondary moment frame designed to less than 5% of seismic demands may be adequate for consideration as a dual system regardless of the 5% rule. INTRODUCTION Design requirements for dual systems were first written into code in the 1959 SEAOC Blue Book and the 191 UBC. Currently, ASCE 7-5 permits a variety of structural systems to be used in combination as a dual system yet the system specific design requirements are still limited to the following: For a dual system, the moment frames shall be capable of resisting at least 5% of the design seismic forces. The

total seismic force resistance is to be provided by the combination of the moment frames and the shear walls or braced frames in proportion to their rigidities (ASCE ). Specifically, dual systems comprised of steel moment resisting frames (MRF) with reduced beam sections (RBS) and buckling-restrained braced frames (BRBF) provide benefits from both an architectural as well as a structural standpoint. While the MRFs maintain space flexibility and architectural openness, the BRBFs help provide stiffness and control interstory drifts in mid-to-high rise structures (SEAOC Seismology Committee 7). This drift control by the BRBFs is particularly apparent in the lower levels. In the upper levels, the MRFs will be a more effective system for drift control. This behavior is illustrated in Figure 1 where the idealized resultant DS displaced shape is linear with respect to the buildings height (Maley et al. 1). + = BRBF + MRF = DS Figure 1: Simplified displaced shape of respective systems in tall buildings Buckling-restrained braces (BRBs) provide damping to a structure in the event of the earthquake due to their low post-yield stiffness and hysteretic behavior. Typically, while dissipating energy, this behavior causes relatively large residual displacements after a large earthquake. Providing a MRF to remain elastic until after the BRBF yields allows force re-distribution from the BRBFs to the MRFs to restrict these large displacements and protect the structure. Using both MRFs and BRBFs together in a dual system allows the benefits of both systems to be utilized and the short-comings of both the BRBFs and MRFs to be mitigated by the other (EERI 199). The purpose of this paper is to compare the inelastic behavior of three dual system models specifically designed for this analysis. The effect of designing a secondary system for 15% (not meeting code requirements), 5%, and % (exceeding code requirements) of the base shear has been examined through nonlinear static pushover (NSP) and response history analysis (RHA) and conclusions are drawn from the effects of the backup system strength on the behavior and intent of a the dual system. PROTOTYPE MODELS A story building was chosen to be examined for this study, with a rectangular plan of dimensions 1 by 1. The -dimensional analysis represented

the lateral force resisting system of the structure in one direction. One exterior braced frame line was modeled in series with an interior moment frame line connected by a rigid diaphragm. The typical bay sizes in the direction modeled are - with story heights of 13 - and an - first floor lobby (Figure ). The alternating pattern of the braces on the building elevation helps reduce column sizes by coupling the tension and compression braces. Similar gravity loading criteria was used from the SAC project for assessment of moment frames in response to the 199 Northridge Earthquake (FEMA 355C). Figure : Elevation of dual system The prototype structures were designed for a theoretical location of Los Angeles, California. Per the United States Geological Survey (USGS), the maximum spectral acceleration seen at the site is approximately g for short period buildings, and attains around.5g for long period structures. Based on ASCE 7-5 including supplement II, the upper limit fundamental period (1. seconds) and the minimum base shear governed the design of the structure. For an overall building weight of 9, kips distributed evenly among the floors, the total calculated base shear of the structure is approximately % of the total building weight. A Response Modification Coefficient of R= was adopted per ASCE 7-5 Table 1.-1. Three separate buildings were designed for this analysis. The baseline model is a dual system with a backup special moment-resisting frame (SMRF) designed for 5% capacity of the seismic demands on the structure. Results reported are bound by two other models with a backup SMRF designed to 15% and % strength. DESIGN PROCEDURE The three step design procedure below was used for the prototype models in this analysis as described by Magnusson, 1997: 1. Design BRBF for full lateral resistance based on the equivalent static force procedure given in ASCE 7-5 1..

. Design SMRF for 15%, 5%, and % of demands per ASCE 7-5 1.. 3. Combine systems and reduce BRBF designs based on the relative rigidity of the BRBF to SMRF using modal response spectrum analysis as described in ASCE 7-5 1.9. The design utilized ASTM A99 Grade 5 steel (yield stress of 5 ksi) for all beams and columns. The BRB core yield stress was taken as 3 ksi for design. In order to develop an anticipated yielding sequence from the top of the structure down, demand-capacity-ratio (DCR) values were most conservative at the bottom levels and near unity at the top of the structure. Typical brace core areas in Models 15, 5, and are. in at the roof for all structures, and 1.75 in, 1.5 in, and 1.5 in at the first floor, respectively. SMRF beams used are W1x, W1x, and W1x5 at the roof and W1x5, Wx7, and Wx9 at the first level for Models 15, 5, and, respectively. Columns at the first floor are W1x55 and W1x55 for the interior braced frame and moment frames respectively in Models 15 and 5 and W1x55 and W1x5 for the interior braced frame and moment frames respectively of Model. W1x53 columns are used at the roof of each braced frame and the SMRF of all three models uses W1x13 columns. Additional member sizes and model information is provided in Aukeman, 11. Static analysis of the design forces show the stiffness ratio of the MF to BF of Model 15, 5, and is 17%, 19% and % respectively. MODELING FOR NONLINEAR ANALYSIS Nonlinear elements used in Perform 3D are BRB element compounds, moment-rotation hinges for reduced beam sections and BRBF beams outside gusset connections, P-M-M3 (PMM) Rotation Hinges for columns to consider the axial moment interaction. In addition, elastic section properties were assigned to beams and columns where nonlinear behavior was not expected and rigid elements at beamcolumn intersections and gusset locations in the BRBF. The base of the SMRF elevation was assumed to be pinned with a large steel grade beam while the BRBF columns were fixed where the braces are located at the foundation and pinned elsewhere. All elements were modeled with expected yield stresses (55 ksi for beams and columns and ksi for braces). NONLINEAR ANALYSIS The nonlinear response of the building was assessed by means of nonlinear static (pushover) and nonlinear dynamic analyses. Nonlinear Static Analysis. A modal pushover was executed to reveal the relative behavior between the BF and MF for each model. Loading was applied based on the first mode force distribution where story forces vary with respect to story elevation as calculated in the linear static procedure.

The total base shear and the base shears in the braced frame and moment frame are shown below in Figure 3 as a function of the roof drift angle. For each model, the target displacement δ t was calculated based on the modal pushover analyses for the design earthquake values using ASCE 1-3.3.3.3. and is indicated in Figure 3 around. radians or inches roof displacement. MF Shear BF Shear Total Shear MF Shear BF Shear Total Shear V/W.15.1.9..3 V/W.15.1.9..3. δ t..1..3 Roof Drift Angle, Radians (a) Model 15. δ t..1..3 Roof Drift Angle, Radians (b) Model 5 V/W MF Shear BF Shear Total Shear.15.1.9..3 V/W Model Model 5 Model 15.15.1.9..3. δ t..1..3 Roof Drift Angle, Radians (c) Model. δ t..1..3 Roof Drift Angle, Radians (d) Total Force Figure 3: Modal Pushover Force Displacement Curves The base shear value that causes first yield is approximately equal to the design base shear of.w (see Figure 3 (d)). In the figures below the yielding of the braces at the upper levels cause the initial change in stiffness; however the capacity continues to increase as the conservatism of design is apparent as a result of safety factors, the gradual propagation of yielding and strain hardening. For all three models, failure is caused by a lower level column being loaded beyond its allowable axial-flexure interaction envelope and the pushover analysis is stopped. While this is not a desirable failure mechanism, the structure has been loaded well beyond its design force and has displaced to beyond.5 radians ( - ) or almost four times the target displacement, δ t, as described in ASCE 1-.

Figure 3 (c) shows the uniqueness of Model and the MF has a significantly higher capacity than the BRBF. Since ASCE 7-5 allows a reduction in strength of the braced frame (based on stiffness), the overall force displacement relationships of the different models were compared for each load pattern. Small strength reductions were made to the braced frames due to the small relative stiffness of the MF to the BF. With these reductions, the largest difference in force-displacement relationship was seen as a result of the moment frame strength rather than the reduced braced frame strength. This can be observed in Figure 3 as each BRBF has approximately the same maximum strength equal to.w. Nonlinear Dynamic Analysis. To explore the variability of seismic ground motions, a suite of 7 earthquakes were selected and the median and th percentile response quantities are reported below. The 7 records were scaled to the design spectrum using the amplitude scaling procedure according to ASCE 1 1... A list of ground motions, their unscaled peak ground accelerations and the amplitude scale factors used for this analysis is shown in Table 1. The response spectrum for the suite is shown below in Figure. Spectral Acceleration, g 5 3 1 Average SRSS DE Spectra 9% of 1.3xDesign Spectra.T T 1.5T Table 1: Earthquake record data Earthquake Record Station PGA (g) Scale Factor Northridge Canoga Park.3.15 Loma Prieta Capitola.53.55 Imperial Valley Bonds Corner.7.3 Imperial Valley El Centro.35. Kalamata Kalamata.5 3. Coalinga Pleasant Valley.3 3.5 Northridge Saticoy Station.37 1.77.T T 1.5T 1 3 Period, s Figure : Earthquake spectral scaling for response spectrum BRB hysteresis properties and modal damping of 1.9% has been assigned in Perform 3D along with a small.1% Raleigh damping at.5t and 1.5T (varying at other periods) to account for additional damping in short period modes. For all three models, only the El Centro record induced deformations high enough to terminate the analysis. This ground motion exhibited a large pulse around. sec into the record causing large roof displacement and high ductility demands in the BRB elements that cause termination. All data from the El Centro record includes only building response data for the first.5 seconds (or until the maximum allowable BRB deformation of 15 times the yield displacement is reached). The remaining records did not cause deformations beyond the elements maximum deformations. For the results presented from the response history analysis, the median and th percentile values have been indicated. The median is reported as the value of the th highest result of the 7 records while the th percentile result is approximated as

data point (since /7=. which is nearest.). The th percentile value can be regarded as the median response plus one standard deviation. This method was used in FEMA 355C for the SAC project when one or more earthquake records caused failure of the structure Interstory Drift. The median and th percentile values for the maximum interstory drift angle for each level (not concurrent) are shown in Figure 5. Story Level, i 1 1 1.5.1.15 Interstory Drift Angle, Radians Model 15: Median Model 15: th Percentile Model 5: Median Model 5: th Percentile Model : Median Model : th Percentile Figure 5: Nonlinear dynamic interstory drift results The varying design criteria between models results in unique interstory drift demands. Model 5 experiences the overall highest th percentile interstory drift ratio equal to.1 radians at level 1. Model 15 experiences the largest range of drift values as the difference between the median and th percentile results is the highest. As the moment frame strength increases in the models, the range between the median and th percentile results decrease. Different trends can be observed for the upper and lower portions of the structure as an inflection point is observed near level 9. This behavior corresponds to the way the BF and MF engage each other as shown in Figure 1. These results show that no conclusive statement can be made about which design is optimal for minimizing interstory drift. ASCE 7-5 provides a limit of.h sx for drift in Table 1.1-1. Figure 5 shows that all three models performed well within the code limits for interstory drift. If a stricter drift limit of.1 h sx is used, only Model would pass. Such a drift limit could be applied to high performance structures and hospitals. Displacements. The displaced shape corresponding to the maximum roof displacement normalized by the roof height is displayed in Figure. Similar behavior is observed between the three models. The magnitude of the median roof drift is

approximately.5 for each model which is less than the target displacement roof drift of. radians. The displacement data of Model shows the least variability between earthquake records while Model 15 demonstrates more scattered results at the lower levels. For all three structures the El Centro record induced the highest roof displacements. For the El Centro ground motion specifically, the stronger moment frame structures underwent less roof displacement at the time the lowest level braces reached their maximum allowable ductility. Floor level, i 1 1 1 Floor level, i Floor level, i 1 1 1.3..9 Δ/h (a) Model 15 1 1 1.3..9 Δ/h (c) Model.3..9 Δ/h (b) Model 5 Northridge Canoga Park Loma Prieta Capitola Imperial Valley Bonds Corner Kalamata Kalamata Coalinga Pleasant Valley Northridge Saticoy Station Imperial Valley El Centro Figure : Nonlinear Dynamic Maximum Roof Displacement Ductility. For each structure, the ductility ratios have been calculated as the ratio of element demand to yield capacity. As shown below in Figure 7, the th percentile RBS ductility ratio for all three models ranges from 1.5 to 1.75 which classified by

ASCE 1- as the Immediate Occupancy performance category. This means that only mild plastic behavior was seen from the RHA. The th percentile results also show Model is likely to see the least ductility demand in an earthquake. Story Level, i Model 15 Median Model 5 Median Model Median Model 15 th Percentile Model 5 th Percentile Model th Percentile 1 1 1 1 1 1.5 1. 1.5..5. 5.. 7.. 9. RBS Ductility Ratio, μ BRB Ductility Ratio, μ (a) Figure 7: Nonlinear Dynamic Ductility Ratios The results for maximum BRB ductility demands reported in Figure 7 for levels 1 through 9 show a clear trend in the th percentile data as Model experiences the least ductility and Model 15 experiences the most. th percentile ductility values at levels 1 through correspond to relatively higher interstory drifts in Figure 5. In the case of model 5, where BRB ductility is highest, the RBS ductility is also higher as demands shed from the BRBF into the MF as intended. The th percentile results of all three models for BRB ductility in Figure 7 (b) range from.5 to.. BRB element testing shows core yielding beyond 15 times the yield displacement is unsafe. For all BRB elements in the three models, the th percentile data presented above is also within the Immediate Occupancy to Life Safety range. Both RBS and BRB ductility responses show the 3 prototype structures behave similarly. Base Shear. The median values for the base shear distribution is shown below for the instant at which the total base shear was a maximum in the Nonlinear Dynamic (ND) analysis (Figure (a)) and the instant at which the MF shear was a maximum (Figure (b)). These results show the total ND base shear demands far exceed the overall design base shear of.w. Also, the nonlinear force distribution shows the MF appropriately take on more load as the structure yields to maintain drift control during the ND analysis. For all three models, the MF shear demands are approximately 5% or more of the overall shear. In Figure (b), when the MF resists the maximum load, the shear distribution ratio is greater than 5%. The maximum total base shear imposed on Model 5 (and similarly Models 15 and ) exceeds the ultimate capacity Story Level, i (b)

shown in Figure 3. Aside from the difference in procedure, the hysteretic behavior of the BRB elements has been modeled explicitly based on test data. Due to cyclic strain hardening the capacities of the BRB elements increase as the members cycle back and forth..3.3.5.5 MF BF Base Shear, V/W..15.1.5.7.5. Base Shear, V/W..15.1.5.7.5.91. Model 15 Model 5 Model (a) Figure : (a) Median ND total base shear. (b) Median ND base shear at maximum MF base shear. CONCLUSION Drift and displacement demands did not show one model as performing significantly better than another. The MF designed to % of the design base shear resulted in the least scatter of results from the 7 ground motions, however all models performed adequately based on ASCE 7-5. The general displacement profile for each structure was close to linear as expected for a BRBF and MF Dual System. In terms of th percentile demands from the RHA, the interstory drift demands remained below.1. The ductility demands for the BRBs remained below.3, well within the acceptable range. The RBS ductility demands attained by the MF are approximately only mildly inelastic. As expected, the story shear results showed that the stronger moment frames resisted the highest base shear in the nonlinear pushover as well as the response history analyses in general. Shear reversal (MF and BRBF working against each other) was observed in levels where braces occurred in adjacent interior bays. The implications of such shear reversal are unclear and should be examined further. This is related to the alternating brace patterns. ASCE 7-5 requires a secondary system to be designed for a minimum of 5% of the seismic base shear; however the results show that the Model 15 performs similar to the Model 5. Thus there appears to be no clear argument to not categorize it as a dual system. Clearly, the design technique presented here for a dual seismic force resisting system provides a high performance structure. This paper shows that advanced analysis is required in order to fully quantify the system performance and required MF strength with respect to the performance criteria, and to quantify the added cost of the backup MF system.. Model 15 Model 5 Model (b)

This paper shows that the 5% design rule at best is arbitrary. It should be investigated if a better design rule could be based purely on strength distribution between the BRBF and MF, e.g. 75%/5%. Otherwise the BRBF design hardly changes with varying MF strength causing uneven levels of conservatism. The allowed strength reduction of the BRBF (step 3 in design procedure) was relatively small for these systems and did not cause any deficiencies in the dual system performance. Overall, all models were found to easily satisfy the drift and ductility limitations. However, for a more complete picture of the dual system performance, an additional study should be completed for a pure BRBF to quantify the MF contribution to the overall dual system behavior. The results presented above may vary dramatically between dual system types as well as building layouts. It is suggested that this research may be continued with additional variations to better understand the design implications of mixing stiff and flexible systems in a dual seismic force resisting system. REFERENCES American Society of Civil Engineers (ASCE) (). ASCE 7-5 Minimum Design Loads for Buildings and Other Structures. American Society of Civil Engineers (ASCE) (7). ASCE 1- Seismic Rehabilitation of Existing Buildings. Reston, Virginia. Aukeman, L. J. et. al. (11) Evaluation of the ASCE 7-5 Design Rule for Relative Strength in a Tall Buckling-Restrained Braced Frame Dual System. San Luis Obispo, CA. Earthquake Engineering Research Institute (EERI) (199). Connections: The EERI Oral History Series, Henry J. Degenkolb. Stanley Scott interviewer/editor, Oakland, CA. Federal Emergency Management Agency (FEMA).. FEMA 355C State of the Art Report of Systems Performance of Steel Moment Frames Subject to Earthquake Ground Shaking. Redwood City, CA. Magnusson, J. D. (1997). "Earthquake-Resisting Dual Systems and the 5% Rule." Building to Last: Proceedings of Structural Congress. vol 1. ASCE, NY 1997. Maley T. et al. (1). Development of a Displacement-Based Design Method for Steel Dual Systems with Buckling-Restrained Braces and Moment-Resisting Frames, Journal of Earthquake Engineering, 1:1, -1. Structural Engineers Association of California (SEAOC) Seismology Committee. (7). The SEAOC Blue Book: Seismic Design Recommendations, Jan. 7, 17 Aug. 9. <http://www.seaoc.org/bluebook/index.html>. International conference of Building Officials (ICBO). (191). Uniform Building Code, Whittier, CA.