Learning Objectives: Proteomics Isoelectric Focussing

Similar documents
Agilent 3100 OFFGEL Fractionator Kit

Methodology for Immunohistochemistry. Learning Objectives:

Fig. 1: Experimental design for 2-D gel electrophoresis: Cultured cells are grown under

ExcelGel 2-D Homogeneous Instructions

2.0. User Manual. Protein Staining System. Mar 28, For fast Coomassie blue staining of proteins in mini polyacrylamide gels

Advanced Protein Electrophoresis. Advanced Protein Electrophoresis. Learning Objective. Proteomics ; Molecular & cell Biology

ECIS 8W and 24W Trans-Filter Adapter Application Note

User Guide. Part No.: BPLUS10. High Pass Plus TM Gel Cassettes. High Pass DNA Size Selection. Doc. #460045

Ion Exchange Chromatography. Learning Objectives:

Version No For fast semi-dry electroblotting of proteins from mini polyacrylamide gels to nitrocellulose or PVDF membranes

Multiple SDS-PAGE on Vertical Electrophoresis Units

GeneGel HyRes Starter Kit

User Guide BLF-7510 BUF High-Pass TM DNA Size Selection. Sage Science Part Nos:

The Biology CRO. Protein Staining System. For electric staining of proteins in mini polyacrylamide gels. Version 1.0 April 3, 2010.

Typical Experiments. How it Works

User Guide PAC-20KB PAC-30KB. High-Pass TM DNA Size Selection. Sage Science Part Nos:

PORTABLE ph METER PRICE CODE NUMBER MODEL 100

User Guide PAC-20KB PAC-30KB. High-Pass TM DNA Size Selection. of SMRTbell TM templates for PacBio RS Sequencing. Sage Science Part Nos:

Basic Biotechnology Kit

A. Introduction. Figure 1 Figure 2

Dissolved Oxygen Probe (Order Code: DO-BTA)

Supplementary Material. The MIAPE-GE glossary (MIAPE-GE version 1.4).

PrepFiler Express and PrepFiler Express BTA Forensic DNA Extraction Kits

HYDROLOGY INVESTIGATION Electrical Conductivity. What is Conductivity?

Agilent 2100 Bioanalyzer (PSC 533)

Family Secrets. Part 4 Testing for the HD Gene

IR-Blot Secondary antibodies Rev00

Isoelectric Focusing on DryGel IEF

F Series Flow Meter F300. User Manual

AGAROSE GEL ELECTROPHORESIS Modified from Wolbachia FIBR Project, Rochester University

Operation guide. High Capacity Stacker-H1

Conventional isoelectric focusing with the Agilent 3100 OFFGEL Fractionator

BQ Revision : 1 ( )

DNA FINGERPRINTING 3/2003 TEACHER PREPARATION AND INSTRUCTION GUIDE FOR USE WITH CAROLINA BLU STAIN

64C Amplification Block. Instruction Manual

IR-Blot Secondary antibodies Rev01

Dog IgG1 ELISA Quantitation Set

Users guide. Zsélyi Aladár u Budapest, Hungary Tel: (36-1) , Fax: Home page:

Human IgG ELISA Quantitation Set

ecosphere water purifier 3in1 USER MANUAL

1µl Assay for DNA, RNA & Oligos

Guidelines for Using the Sage Science Pippin Pulse Electrophoresis Power Supply System

BIL 256 Cell and Molecular Biology Lab Spring, Molecular Weight Determination: SDS Electrophoresis

BENTLEY BACTOCOUNT IBC INDUSTRY OPERATOR (BClO) APPROVAL PROCEDURES PROTOCOL

Instruction Manual. ph20 ph21. Basic ph meters

IEF Electrophoresis SCST Genetic Testing Super Workshop

IEF Electrophoresis SCST Genetic Testing Super Workshop

Normalization, Dilution and Transfer Methods for the Maxprep TM Liquid Handler Technical Manual

Instruction Manual HI Portable ph/ec/tds/ C Meters

Two-Dimensional Gel Electrophoresis

C300 Cond/TDS/Sal/T Meter. Manual

Histology FISH Accessory Kit Step-by-Step Procedure

Rat / Mouse Amylin EIA Kit

Agilent High Sensitivity DNA Kit Guide

Biochemical Oxygen Demand

Reagent Kit Guide RNA 6000 Nano Assay. Edition April 2003

ANG 111 Summer 2009 Laboratory 0: Basic Laboratory Procedures. To provide a foundation in basic laboratory techniques and safety issues

Next Review Date: Oct 2017 SWP Reference Number: Version: V3 Version Issue Date: Oct 2016

Lab 1 Flow Chart : Learning basic laboratory skills

Preparation thin blood films and Giemsa staining

IEF-2DE Analysis and Protein Identification Xia Wu 1, Steven J. Clough 2, Steven C. Huber 3 and Man-Ho Oh 4*

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

BC Series Compact Counting Scale INSTRUCTION MANUAL

HRO-50 Water Purifier

Prepare 2 jars with 96 % ethanol. Prepare 2 jars with 70 % ethanol

2-Dimensional Electrophoresis

BIOLOGY 163 LABORATORY. RESTRICTION MAPPING OF PLASMID DNA (Revised Fall 2017)

Human DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure

ImmunoTag Human HIV ( antibodies plus p24 antigen ELISA Kit

Warranty and Liability. QC Test. Trademarks

Operation Manual. Concorde Vertical Gel Electrophoresis System. *This instrument is intended for laboratory use only.

To whom it may concern, February 21, 2011

Porcine IgM (Immunoglobulin M) ELISA Kit

electrophoresis tech Versatile Separation Capabilities of the PROTEAN i12 IEF System

Using Electrophoresis and other Separation Techniques in High School Science

Chicken Calprotectin ELISA Kit. User Manual

Bacterial Transformation and Protein Purification

Introduction The Van London Co. Cadmium Ion Electrode is used to measure Cadmium ions in aqueous solutions.

Human IL-6 ELISA Test Kit Manual Catalog #: 2107 Reference #:

Operating Manual for Digital ph-meter GPHR 1400

S E C T I O N S C O V E R E D

Experion RNA StdSens Analysis Kit Instruction Manual

Model DDS-11C Conductivity Meter Operation Manual Shanghai San-Xin Instrumentation,Inc.

Principles and Practice of Agarose Gel Electrophoresis

BIOSCAN* ATP method for monitoring of biofilm/sessile microorganisms in cooling systems

ReadyPrep Reduction-Alkylation Kit

ABI Prism 310 Cycle Sequencing Protocol Economy Version

EasyPrep TM Plant Genomic DNA. Miniprep Manual. Table of Contents. Introduction Kit Contents... 4

Evaluation copy. Chloride and Salinity. Computer INTRODUCTION

Agilent 3100 OFFGEL Fractionator pi-based fractionation of proteins and peptides with liquid-phase recovery

Restriction Analysis of Purified para-r

Complete kit for the systematic analysis of protein kinases from a proteome such as cell lysate, tissue or microorganisms.

User s Manual. KSV NIMA Dip Coaters

TurboCASH Business Class

MEDIZINTECHNIK FÜR TIERÄRZTE

Labor estimates function. We recommend reading our Vehicles in Shop and Repair Page guide prior to this one.

Total Aflatoxin ELISA Test Kit Manual Catalog #: 1030 Reference #:

Lab 8: Bacterial Transformation with pglo for Protein Production

Transcription:

Proteomics Isoelectric Focussing Isoelectric Focussing Proteins exhibit unique iso-electric property, such unique property of the proteins are exploited for the separation into individual proteins from a pool of proteome. Each single protein can be separated from one another by iso-electric property. Learning Objectives: After interacting with this learning object, the learner will be able to: Define first dimension separation of proteins using Iso-Electric Focusing (IEF) system. Operate steps involved in handling the instrument and the materials used. Recall the background to Iso-Electric Focusing (IEF). Infer the steps involved to perform in the experiment. Assess the troubleshooting steps involved in the experiments. Note: The current IDD exists in two modes- interactive and automatic. Students taking lab course should select interactive (set as default), while the automatic mode may be selected for general users.

Cleaning and Drying the IPG Tray Take out the tray/manifold and place it on the table. Clean all the lanes of tray/manifold with tissue paper, to make it free from dust, moisture and dry it completely before use.

Position the Manifold Place the instrument on leveled and shock free surface. Now, position the manifold inside the groove of the instrument. Ensure that the surface is even by placing the round spirit level and making necessary adjustment at the back edge of the instrument. The manifold surface must be leveled, inorder to avoid any leakage of cover fluid during the run.

Transfer IPG strips to Manifold Soon after passive rehydration, pick the strip from the reswelling tray using forceps. Drain out excess oil by tapping it on tissue paper by holding it straight not folding/bending it. Place the positive side of strip on the positive end of the instrument with gel side up.

Moisten and place the Electrode Wicks Cut the paper wicks into two pieces. Add distilled water to the wicks until it gets wet. Place the wick over the end of the strip such that 1/3 portion of it touches the gel surface. The paper wicks absorb impurities /salts and aid in current conductance.

Pour Cover fluid Add cover fluid in all the wells containing the strips and to the other wells. Maintain the level of cover fluid to prevent it from over flowing.

Position Electrode Assembly Place the electrodes on either side of the tray such that the tip of the electrode touches the paper wick and is immersed in the cover fluid and close the lid. The electrode assembly must be placed between the marked places on the platform. Different markings are provided according to the strip length which helps the user to be sure that the assembly is placed correctly.

Switch ON the instrument Connect the instrument properly. Switch ON the system and Start the software by clicking on the icon. Once instrument is ON it automatically calibrates to check all the parameters and working status. Once it is done, the system displays a ready status for the user to proceed.

Set program parameters and run IEF Select the specific protocol for the choice of the sample to run the IEF. The protocol must be specified and initial run must be performed before going for the final run.

Set program parameters and run IEF User can change and define the protocol according to sample requirements.

Set program parameters and run IEF User is provided with option to select the strip length and define the number of strips run for the experiment.

Set program parameters and run IEF Once the protocol has been defined, it is connected to the instrument and transferred to the instrument.

Set program parameters and run IEF Start the run. The set voltage is reached if the sample preparation is perfect and the IEF run condition will be achieved without any interference.

Set program parameters and run IEF However, the set voltage will not be attained if the sample contains impurities which may interfere during the run.

Set program parameters and run IEF If the running voltage deviates from set voltage, press pause icon to stop the focusing.

Set program parameters and run IEF In case of improper run replace the wicks with the new one. The wick turning yellow is an indication of abnormal run. The user needs to clean-up the sample and perform the run if the wicks turn very dark yellow. Just in case the wicks are light yellow, the wicks can be changed and the focusing can be carried out.

Set program parameters and run IEF Re-start the run by clicking on play button.

Set program parameters and run IEF The run continues once the wicks are changed.

Mechanism of Separation Under the influence of applied electric field, the proteins start moving till they reach a point where the net charge on them is zero, this particular point where the protein has a net charge zero is called Isoelectric point. Each protein differs from the other based on the Isoelectric point and this property of the protein is exploited during the separation of proteins during Isoelectric focusing.

Mechanism of Separation At iso-electric point the number of positive charges is equal to the number of negative charges present on the protein.

Completion of IEF Stop the run once the set voltage is reached and the run is completed.

Storing the Strip Remove the IPG strip using forceps with care must be taken not to bend the strip and excess oil must removed by soaking over the tissue.

Storing the Strip Store the strip at -80 C until further processing. Once the equilibration buffer is prepared the strip can be taken out to carry out 2D run. Do follow the future viewing IDD for more information.

Proteomics Extraction of Bacterial Protein