QbD approach for analytical method development of anti-pschotic drug

Similar documents
A Simple Rapid and Sensitive Method Development for Quantification of Quetiapine Fumarate in Bulk and Dosage Forms Using RP-HPLC

10. Validated Normal Phase HPLC Method for the Determination. Fulvestrant is primarily used in the treatment of hormone receptor

Journal of Pharmaceutical and Bioanalytical Science

Lakshmana Rao et.al Indian Journal of Research in Pharmacy and Biotechnology ISSN: (Print) ISSN: (Online)

International Journal of Pharma Research and Health Sciences. Available online at

Research Paper Development of Stability Indicating Reverse Phase HPLC Method for Aripiprazole from Solid Dosage form

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

Development and Validation of Isoniazid in Bulk and Pharmaceutical Dosage Forms by UFLC Method

Development and validation of stability indicating RP-HPLC method for the estimation of Daclatasvir in bulk and formulation

P. Wadhwani College of Pharmacy, Yavatmal , India. *Corres.author: Cell No

Intercontinental journal of pharmaceutical Investigations and Research

Analytical Method Development and Validation for the Estimation of Abiraterone and its Impurity in Pharmaceutical Formulation By RP-HPLC

ISSN India; g,secunderabad. Abstractt. a flow rate. of 1ml/min. di hydrogen. which acts. and chronic. including minimize (5) Figure

IAJPS 2017, 4 (07), P. Hari Sravanth Reddy et al ISSN

INTERNATIONAL RESEARCH JOURNAL OF PHARMACY

RP-HPLC Method for the Simultaneous Estimation of Lamivudine and Abacavir Sulphate in Tablet Dosage Form

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

DEVELOPMENT AND VALIDATION OF ANALYTICAL METHOD FOR ASSAY DETERMINATION OF ISOSULFAN BLUE BY LIQUID CHROMATOGRAPHY

Usharani Gundala* 1, Chandrashekar Bonagiri 2, Devanna Nayakanti 3

RP-HPLC METHOD FOR QUANTITATIVE ESTIMATION OF GLATIRAMER ACETATE FOR INJECTION IN PHARMACEUTICAL DOSAGE FORMS

Short Communication Stability Indicating Assay Method Development and Validation of Tolteridone Tartrate in Bulk Drug and Capsules

Available Online through (or) IJPBS Volume 2 Issue 3 JULY-SEPT Research Article Pharmaceutical Sciences

Application Note. Author. Abstract. Pharmaceuticals. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Development and Validation of RP-HPLC-PDA Method for Simultaneous Estimation of Baclofen and Tizanidine in Bulk and Dosage Forms

Saudi Journal of Medical and Pharmaceutical Sciences

ISSN: X CODEN: IJPTFI Available Online through Research Article

CHAPTER-3. Zolmitriptan

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Validated Stability-indicating assay method for determination of Ilaprazole in bulk drug and tablets by high performance liquid chromatography

Automated QbD-Based Method Development and Validation of Oxidative Degraded Atorvastatin

Peptide Mapping: A Quality by Design (QbD) Approach

International Journal of ChemTech Research CODEN (USA): IJCRGG, ISSN: , ISSN(Online): Vol.10 No.6, pp , 2017

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

CHAPTER III STABILITY INDICATING ASSAY AND IMPURITIES METHODS FOR FIXED DOSE COMBINATION PRODUCT OF OMEPRAZOLE AND DOMPERIDONE

Preparative Purification of Corticosteroids by HPLC; Scalability and Loadability Using Agilent Prep C18 HPLC Columns Application

Jigar Mehta, Yauvan Pancholi, Vipul Patel, Nayan Kshatri, Niranjan Vyas*

THESIS SUBMITTED TO THE ANDHRA UNIVERSITY IN PARTIAL FULFILMENT FOR THE AWARD OF THE DEGREE OF DOCTOR OF PHILOSOPHY IN PHARMACEUTICAL SCIENCES

Simultaneous Estimation of Finasteride and Tamsulosin Hydrochloride in Combined Dosage Forms by RP-HPLC-PDA Method

Emulation of the Agilent 1100 Series LC Through Waters Empower Software Analysis of an Analgesic Mixture

STABILITY STUDIES OF RIBAVIRIN SYRUP

Quality-by-Design-Based Method Development Using an Agilent 1290 Infinity II LC

Asian Journal of Research in Chemistry and Pharmaceutical Sciences Journal home page:

Validated Stability Indicating RP-hplc Method for the Assay of Dienogest in Bulk and Tablet Dosage Form

International Journal of Applied Pharmaceutical Sciences and Research

Validation of Analytical Methods used for the Characterization, Physicochemical and Functional Analysis and of Biopharmaceuticals.

DIDANOSINE ORAL POWDER Final text for addition to The International Pharmacopoeia

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

International Journal of Institutional Pharmacy and Life Sciences 6(5): September-October 2016

Quantitative determination of residual 2-(2-chloroethoxy) ethanol (CEE) in quetiapine fumarate by gas chromatogaraphy

RESEARCH ARTICLE STABILITY INDICATING ANALYTICAL METHOD DEVELOPMENT AND VALIDATION FOR THE ESTIMATION OF AVANAFIL IN PHARMACEUTICAL DOSAGE FORM

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY *)

VICH Topic GL2 (Validation: Methodology) GUIDELINE ON VALIDATION OF ANALYTICAL PROCEDURES: METHODOLOGY

IJSER. (2E)-2-cyano-3-(3,4-dihydroxy-5-nitrophenyl)-N,N-diethylprop-2-enamide [Entacapone] 7

Validation of a Dual Wavelength Size Exclusion HPLC Method with Improved Sensitivity to Detect Aggregates of a Monoclonal Antibody Biotherapeutic

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

Journal of Chemical and Pharmaceutical Research, 2012, 4(1): Research Article

STUDYING THE ACCELERATED PHOTOSTABILITY OF CIPROFLOXACIN AND LOMEFLOXACIN IN TABLETS AND EYE DROPS

Fast and High Resolution Analysis of Intact and Reduced Therapeutic Monoclonal Antibodies (mabs)

9/2/2014. USP Monograph Modernization. Todays topics. USP basic. Todays topics. - USP basic. - USP publications. - USP monograph modernization

DEVELOPMENT AND VALIDATION OF A STABILITY- INDICATING RP-HPLC METHOD FOR THE ESTIMATION OF ERLOTINIB IMPURITIES BY QbD APPROACH

High-Throughput LC/MS Purification of Pharmaceutical Impurities

DACLATASVIR TABLETS (DACLATASVIRI COMPRESSI) Proposal for The International Pharmacopoeia. (May 2018)

Asian Journal of Pharmaceutical Analysis and Medicinal Chemistry Journal home page:

Development and validation of RP-HPLC method for simultaneous estimation of aspirin and omeprazole in dosage

Seamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC

Stability-Indicating RP-HPLC Method for the Simultaneous Determination of Escitalopram Oxalate and Clonazepam

International Journal of Research and Reviews in Pharmacy and Applied science.

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

A Comprehensive Workflow to Optimize and Execute Protein Aggregate Studies

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Determination of Saturated Solubility of Propranololusing UV Visible Spectrophotometer

NISTmAb characterization with a high-performance RP chromatography column

Journal of Chemical and Pharmaceutical Research, 2017, 9(7): Research Article

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

Research Article Validation of a Statistically Optimized Stability Indicating Method for the Estimation of Febuxostat in a Solid Dosage Form

Application Note. Authors. Abstract. Biopharmaceuticals

Losec ٢٠٠٧ ٦ ﺩﺪﻌﻟﺍ ﺮﺸﻋ ﺚﻟﺎﺜﻟﺍ ﺪﻠﺠﳌﺍ ﺔﻴﳌﺎﻌﻟﺍ ﺔﺤﺼﻟﺍ ﺔﻤﻈﻨﻣ ﻂﺳﻮﺘﳌﺍ ﻕﺮﺸﻟ ﺔﻴﺤﺼﻟﺍ ﺔﻠﺠﳌﺍ

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Encompassing Method Development, Small Scale Purification, and Post-Purification Analysis with the Investigator SFC System

Techniques for Reducing the Effects of Sample Solvent on UHPLC Analyses

Scale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system

Method Transfer from an Agilent 1200 Series LC to an Agilent 1260 Infinity II LC

Analysis of amoxicillin and five impurities on the Agilent 1220 Infinity LC System

Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies

INTERNATIONAL PHARMACOPOEIA MONOGRAPH ON ARTEMETHER AND LUMEFANTRINE CAPSULES REVISED DRAFT FOR DISCUSSION

Performance characteristics of the 1260 Infinity Quaternary LC system

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Method Transfer from an Agilent 1260 Infinity LC to an Agilent 1260 Infinity II LC

International Journal of Research in Pharmacy and Life Sciences. International Journal of Research in Pharmacy and Life Sciences

GUIDANCE NOTES ON ANALYTICAL METHOD VALIDATION

Impurity Control in the European Pharmacopoeia

Research Article. Development and validation of RP-HPLC method for the estimation of ropinirole hydrochloride in tablet dosage forms

Application Note. Biopharma. Authors. Abstract. James Martosella, Phu Duong Agilent Technologies, Inc Centreville Rd Wilmington, DE 19808

Development of Quality Control Method for Dissolution Analysis of Tapentadol and paracetamolin tablet

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Rapid UHPLC Analysis of Reduced Monoclonal Antibodies using an Agilent ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C8 Column

Molecular Characterization of Biotherapeutics The Agilent 1260 Infi nity Multi-Detector Bio-SEC Solution with Advanced Light Scattering Detection

Transcription:

Available online at www.scholarsresearchlibrary.com Scholars Research Library Der Pharmacia Lettre, 2015, 7 (12):62-70 (http://scholarsresearchlibrary.com/archive.html) ISSN 0975-5071 USA CODEN: DPLEB4 QbD approach for analytical method development of anti-pschotic drug Omprakash G. Bhusnure *, Nitin G. Shinde, Sachin B. Gholve and Padmaja S. Giram Channabasweshwar Pharmacy College (Degree), Department of Quality Assurance, Maharashtra, India ABSTRACT The scientific way to develop a simple and robust analytical HPLC method for the critical separationsis QbD approach. Quality-by-design (QbD) is a systematic approach to product or process development, which begins with predefined objectives, and uses science and risk management approaches to gainproduct and process understanding and ultimately process control. The concept of QbD canbe extended to analytical methods. A simple Analytical method was developed and used to identify and quantify simultaneously the two active pharmaceutical ingredients Resperidone and Benzoic acid. In the present work, three independent factors were used such as flow rate (A), wavelength (B) and ph of buffer (C). Totally 27 experimental runs were suggested by the software for analyzing the interaction of each level on formulation characters and the peak area (R1), tailing factor (5%) (R2) and number of theoretical plate USP (NTP) (R3) were considered as response factors (dependent factors). The significance of independent factors was determined using Fisher s statistical test for Analysis of the Variance (ANOVA) model that was estimated. Waters Xterra C-18 column (150 mm 4.6 mm, 5 µm pore size), column was the most suitable one since it produced symmetrical peaks with better resolution. The UV detector response of RIS and BA was studied and the best wavelength was found to be 275 nm showing highest sensitivity of both compounds. The method was validated for specificity, reproducibility, accuracy, linearity, robustness and solution stability and can be used for the assessment of quality of drug product in development and stability samples of the marketed oral solution. The target degradation for the stability indicating ability of the assay method was tried in the present study and there was no any interfering peaks found due to degradation products. Keywords: Analytical Method Development, HPLC, QbD approach, DOE, Design Expert INTRODUCTION Risperidone is the most frequently used atypical antipsychotic drug for a treatment of schizophrenia, bipolar disease and behavioral disorders. According to the WHO the mental disorders/diseases are at 3 rd rank in the world as per the survey done by WHO in the 2010 for the DALY index (Disability Adjusted Life Years) [1-3]. Risperidone is a white to almost white powder. It is practically insoluble in water, freely soluble in methylene chloride, sparingly soluble in ethanol, and dissolves in dilute acid solutions. Risperidone exhibits polymorphism. Risperidone is a selective monoaminergic antagonist with unique properties. It has a high affinity for both serotonergic 5-HT2 and dopaminergic D2 receptors. Risperidone binds also to alpha1-adrenergic receptors and, with lower affinity, to H1- histaminergic and alpha2-adrenergic receptors. Risperidone has no affinity for cholinergic receptors. Although risperidone is a potent D2 antagonist, that is considered to improve the positive symptoms of schizophrenia, it causes less depression of motor activity and induction of catalepsy than classical antipsychotics. Balanced central serotonin and dopamine antagonism may reduce extrapyramidal side effect liability and extend the therapeutic activity to the negative and affective symptoms of schizophrenia [4]. 62

Analytic method development and validation are key elements of any pharmaceutical development program. An HPLC analysis method is developed to identify, quantity or purifying compounds of interest. This technical brief will focus on development and validation activities as applied to drug products. Effective method development ensures that laboratory resources are optimized, while methods meet the objectives required at each stage of drug development. Method validation, required by regulatory agencies at certain stages of the drug approval process, is defined as the process of demonstrating that analytical procedures are suitable for their intended use [5-7]. Chromatographic method development can be an time consuming and subjective process. As companies accelerate drug development programs and candidate compounds move through this process, fast and robust HPLC method development becomes increasingly important. Most method development is done using a manual, one-factor-at-atime (OFAT) process where the approach is to vary one system parameter at a time and examine the resultant performance. This procedure is continued until no further improvement is obtained, at which time another parameter is selected for study [8-14]. These separations are often sub-optimal in terms of resolution, tailing, retention time and lack robustness. This can be particularly problematic when preparative chromatography is required to purify milligram to gram amounts of product, as compounds that appear to be well resolved at the analytical scale, may no longer separate efficiently when scaled up, necessitating either further method development or additional product purification steps. This process can be improved by applying a Quality-by-Design (QbD) strategy that develops analytical LC methods to meet performance requirements using sound statistical experimentation principles that accurately quantify system behavior and then scale these up for preparative separations. (1, 2, 3, 4) This can be done using a software based Design Of Experiments (DOE) applications that relies on multivariate modeling to automatically predict and generate optimized analytical HPLC methods that can be transferred to preparative HPLC systems and rapidly scaled up, significantly increasing productivity[15-22]. The primary objective of this study was to implement QbD approach to develop and validate an RP HPLC method and to establish and in-depth understanding of the method and build in the quality during the method development to ensure optimum method performance over the lifetime of the product. MATERIALS AND METHODS Instrumentation HPLC system consisted of Agilent Technologies, US, 1260 Infinity Quaternary LC System model connected to VWD UV detector, column oven and auto sampler (Agilent Technologies, US) was used in this study. Chromatograms were recorded by a computer and treated with the aid of Chrome Eleon. A Watters (Xttera) C18 column (250 mm 4.6 mm id, 5 µm pore size) was used to perform the separation. Milli-Q water was produced with a water purification system, Millipore Corporation (Billerica, MA, USA). The mobile phase was filtered through the Millipore glass filter (Millipore filter cellulose nitrate grided with 0.22 µm size) assembly attached with vacuum pump. The mobile phase was sonicated with Ultrasonic Cleaner 15L, PCI Analytics Pvt. Ltd, Bhandup, West Mumbai. The ph of mobile phase or buffer was measured with Eutech Instruments ph 510 using a glass electrode Van London Co., USA. Chemical and solvents: Risperidone USP (RIS) was provided by Janssen Pharmaceutica Ltd. Wallingstown, Little Island, Ireland. Benzoic Acid (BA) was provided from Panreca Quimica SLV, Belgium. Methanol and acetonitrile were of Analytical Grade and purchased from Finar chemicals pvt ltd company (Gujarat India). Pottasium Dihydrogen Phosphate (KH2PO4) purchased from SDF chemicals, Ltd. Orthophosphoric acid was of analytical grade and procured from Rankem Chemicals Ltd. Mili-Q (0.22µ) water was used for preparing mobile phase and other solutions. Pharmaceutical finished dosage forms utilized in the present work was provided by Janssen Pharmaceutical Ltd. Wallingstown, Little Island, Ireland. Product was marketed as RISPERDAL 1mg/ml oral solution. Chromatographic Conditions: Separation was achieved on Waters Xterra C-18 column (150 mm 4.6 mm, 5 µm pore size) maintained ambient column oven temperature and sampler temperature. Isocratic elution with methanol: water (50:50% v/v) mobile 63

phase at the flow rate of 0.8 ml/min was carried out. The detection was monitored at 275 nm and injection volume was 10 µl. The peak purity was checked with the DAD detector. Standard stock solutions: Stock solutions of 1 mg/ml and 2 mg/ml of RIS and BA respectively were prepared by dissolving them in acetonitrile and water. Standard calibration solutions were prepared by dilution of the stock solutions using the diluent. These solutions were considered at seven different levels which were 25%, 50%, 100%, 150% and 200% of the test concentration[6]. For RIS and BA mixtures, standard solutions of RIS and BA containing a constant concentration of 0.2 mg/ml and 0.4 mg/ml respectively (internal standard) were prepared in diluent by maintaining the concentrations in the range of 0.05 mg/ml to 0.4 mg/ml and 0.1 mg/ml to 0.8 mg/ml respectively. The calibration curves for RIS and BA mixtures were constructed by plotting the peak area against the drug concentration. The diluent is prepared by adding water and acetonitrile (80:20 v/v). Selection of detection wavelength: The detection wavelength was selected by scanning the 10 µg/ml concentration solution of Risperidone and Benzoic Acid in the mobile phase in UV spectrophotometer and maximum absorption was selected as 275 nm. Selection of mobile phase: The pure drug of Risperidone and Benzoic Acid were injected into the HPLC system and run in different mobile phase system. Different mobile phases like acetonitrile, methanol, water and different ph buffer are tried. It was concluded that Potassium phosphate buffer of ph- 3.00 and methanol gives satisfactory results which passes the ICH guideline i.e. ICH Q2 (R1). Hence finalized mobile phase is Methanol and potassium phosphate buffer of ph- 3.00 (50:50). Sample preparations: The label claim of the marketed preparation is 1 mg/ml and 2 mg/ml of RIS and BA respectively. 10 ml of marketed preparation was transferred into a 50ml volumetric flask and made up volume with diluent this is the test solution concentration. Preparation of Phosphate buffer: Potassium dihydrogen phosphate (2.72 g) was dissolved in 1000 ml of Mili-Q water (filtered through 0.22µm size filters) and ph 3.0 was adjusted with orthophosphoric acid. It was filtered through 0.45 µm nylon membrane filter and degassed. It was used for the preparation of mobile phase. System suitability test (SST) / Specificity and formulation analysis: The specificity of method was established by preparing placebo solution by optimized method for assay of the samples using equivalent weight of the placebo with marketed preparation. Chromatogram of the placebo was not showing any interference at the retention time of Risperidone and Benzoic Acid (Figure). The SST ensures the validity of the analytical procedure as well as confirms the resolution between different peaks of interest. All critical parameters tested met the acceptance criteria on all days. Adequate resolution between the RIS and BA peaks ensured the specificity of the method. The system suitability assessment for the analytical HPLC method established instrument performance parameters such as peak area, % R.S.D., column efficiency (N) and USP tailing factor (Tf) for both the analytes. Three different ph of Potassium Dihydrogen Phosphate such as 2.9, 3.0 and 3.1 were studied and optimized with DOE. This ph was used in the study for best retention of acidic drug in a reversedphase system. The mobile phase was selected in 25:25:50 ratio of Acetonitrile: Methanol: Phosphate buffer (ph- 3.00). The 10 µl injection volume was used in the study. The UV detector was used for detection of drug in the samples. As like ph, three different wavelengths such as 270, 275 and 280 nm were studied and one wavelength was selected based on DOE. Similarly, the effect of flow rate (i.e. 0.6, 0.8 and 1.0 ml/min) was studied and based on DOE, the final flow rate was selected. Most of the formulation studies involve only one variant at a time by keeping others as constant. With the help of full factorial design investigators can study the effect of all the factors by varied simultaneously. The factorial design helps to study the effects caused by independent factors and interactions between those self-governing factors [18]. In the present work, three independent factors were used such as flow rate (A), wavelength (B) and ph of buffer (C). Three factorial levels were used in the study and were coded as _1, 0 and +1 for low, medium and high, respectively [19-22]. Totally 27 experimental runs were suggested by the software for analyzing the interaction of each level on formulation characters and the peak area (R1), tailing factor (5%) (R2) and 64

number of theoretical plate USP (NTP) (R3) were considered as response factors (dependent factors). Tables 1 and 2 show the factors chosen and different factor level settings. The significance of independent factors was determined using Fisher s statistical test for Analysis of the Variance (ANOVA) model that was estimated. Table 1: 3 3 Factorial design with upper, middle& lower limits of all factors Statistical Optimization technique 3 Factors 3 Levels Low (-1) Middle (1) High (+1) Flow Rate 0.6 0.8 1.0 ph of Solvent 2.9 3.0 3.1 Column Temperature 20 C 30 30 C The polynomial equation for the experimental design with three factors is given below: = + 1 + 2 + 3 + 2 + 2 + 2 + 2 + 2 + 2 where, R is the response, b is the regression coefficients and A, B and C represent flow rate, wavelength and ph of buffer, respectively. Table 2: 3 3 Factorial design with high & low level factor statistical sequence optimization Run No. Replicates Flow Rate ph of Solvent Column Temperature ( c) 1 3 0.6 2.9 20 2 16 1 2.9 20 3 19 0.6 3.1 20 4 12 1 3.1 20 5 6 0.6 2.9 30 6 4 1 2.9 30 7 15 0.6 3.1 30 8 11 1 3.1 30 9 10 0.46 3 25 10 8 1.13 3 25 11 2 0.8 2.83 25 12 20 0.8 3.16 25 13 18 0.8 3 16.59 14 17 0.8 3 33.40 15 1 0.8 3 25 16 13 0.8 3 25 17 9 0.8 3 25 18 5 0.8 3 25 19 14 0.8 3 25 20 7 0.8 3 25 RESULTS AND DISCUSSION Method optimization Waters Xterra C-18 column (150 mm 4.6 mm, 5 µm pore size), column was the most suitable one since it produced symmetrical peaks with better resolution. The UV detector response of RIS and BA was studied and the best wavelength was found to be 275 nm showing highest sensitivity of both compounds. Several modifications in the mobile phase composition were made in order to study the possibilities of changing the selectivity of the chromatographic system. These modifications included the change of the type and ratio of the organic modifier, flow rate, temperature and stability of RIS and BA was also studied. Initially no peaks were observed when acetonitrile and phosphate buffer in different ratios were utilized, at temperature of 30 C and 1.0 ml/min flow rate on a C8 column. So acetonitrile was replaced by methanol, at that time both drugs again didn t show peaks. Hence the C8 column was replaced by C18 column methanol and phosphate buffer (ph- 3.0) 50:50, peaks of both drugs were observed, but with less resolution and with peak broadening effect for RIS and BA at temperature of 30 C. Then ratio of buffer and methanol was changed to 40:60, peaks of both drugs were observed with good resolution without peak broadening, tailing, fronting and with good sensitivity as well, at 35 C temperature and flow rate of 1.0 ml/min. The effect of flow rate on the separation of peaks was studied by varying the flow rate from 0.5 to 1.3 ml/ min; a flow rate of 0.8 ml/min was optimal for good separation and resolution of peaks in a reasonable time as shown in Fig. 2 shows the chromatogram 65

for a working standard mixture of RIS and BA, respectively. System suitability parameters with peak purity data are given in Table 3. Table 3: System suitability parameters of both drugs (RIS and BA) Sr. No. Parameters Risperidone Benzoic Acid 1 Retention Time 3.045 4.162 2 Resolution USP NA 4.28 3 Theoretical Plates USP 2025 4381 4 Tailing Factor USP 1.16 1.09 Method validation The method was validated according to ICH guidelines. The following validation characteristics were addressed: linearity, range, accuracy, precision, specificity, and robustness. Specificity of the method was determined by analyzing samples containing a mixture of the drug product and excipients. All chromatograms were examined to determine RIS & BA. Formulation analysis and system suitability/ Specificity The assay for the marketed oral solution was established with present chromatographic condition developed and it was found to be more accurate and reliable. The average drug content was found to be 100.9 % for RIS, 100 % for BA. With % RSD for RIS and BA was 0.1 and 0.1 %. Linearity and range Linearity was determined for RIS and BA in the range of 25% - 200% of test solution concentration. The correlation coefficient ( r2 ) values were >0.998 (n = 6) indicating an excellent correlation between peak areas and analyte concentrations. (Table 4 with Graph shown in Fig 1 and 2) 5000000 Risperidone µau 4000000 3000000 2000000 1000000 y = 5473.1x + 22771 R² = 1 Series1 Linear (Series1) 0 0 200 400 600 800 1000 Concentration of Sample Fig 1: Linearity Graph of Risperidone. 66

5000000 Benzoic Acid µau 4000000 3000000 2000000 1000000 y = 5473.1x + 22771 R² = 1 Series1 Linear (Series1) 0 0.00 200.00 400.00 600.00 800.00 1000.00 Concentration of Sample. Fig 2: Linearity Graph of Benzoic Acid Accuracy (% Recovery) The mean percentage recoveries obtained were 101.3%, 100% for RIS and BA respectively. The developed method was found to be accurate as the mean percentage recoveries obtained for RIS and BA were found to be within limit as recommended by ICH guidelines. The developed method was found to be accurate as the % RSD values for accuracy studies were <2% (Table 4), as recommended by ICH guidelines. Table No. 4: Result of validation parameters Sr. No. Parameters Risperidone Benzoic Acid 1 Accuracy / % Recovery 101.3 100 2 Precision (% RSD) 100.9 (0.1%) 100 (0.1%) 3 % Assay 100.6 100 4 Linearity (r 2 value) 1.000 1.000 Method Precision The system precision was demonstrated by preparing the standard solution at test concentration and injected repeatedly for six times. The % RSD for repeatability of sample preparation is 0.12 % and 0.07 % for RIS and BA respectively. The precision is satisfactory and the % RSD is not more than 2.0% as per ICH guidelines. The results are shown in Table 4. Robustness and solution stability studies The % Assay and % RSD was found to be in range 100 ± 1.5% and <2, respectively. It indicates that method follow specification of ICH guideline. Results of the stability studies were in the range of 99.5-101.5%. Stability as described in method development under experimental section was studied. Results of the stability studies were within the acceptable limit (98-102%). Forced Degradation As per ICH guidelines, the target degradation below 0.5% should be there for the stability indicating ability of the assay method and the same was tried in the present study. No interfering peaks were found due to degradation products at the drugs Rt s. 67

Fig. 3 - Effect of Flow rate and ph of Solvent at medium level Fig. 4 - Effect of Flow rate and ph of Solvent at low level 68

Fig. 5 - Effect of Flow rate and ph of Solvent at high level CONCLUSION A robust method for degradation of Risperidone and Benzoic was developed using a Quality by Design approch on an Design-Expert Software, Version 9. Three independent factors were used such as flow rate (A), wavelength (B) and ph of buffer (C). Totally 27 experimental runs were suggested by the software for analyzing the interaction of each level on formulation characters and the peak area (R1), tailing factor (5%) (R2) and number of theoretical plate USP (NTP) (R3) were considered as response factors (dependent factors). The method was validated according to ICH guidelines. Specificity of the method was determined by analyzing samples containing a mixture of the drug product and excipients. The assay for the marketed oral solution was established with present chromatographic condition developed and it was found to be more accurate and reliable. The % Assay and % RSD was found to be in range 100 ± 1.5% and <2, respectively. It indicates that method follow specification of ICH guideline. Results of the stability studies were in the range of 99.5-101.5%. As per ICH guidelines, the target degradation for the stability indicating ability of the assay method was tried in the present study. No interfering peaks were found due to degradation products at the drugs Rt s. Design Expert was able to automatically predict and test speed and resolution optimized analytical methods that separated all the drug peaks. Analytical to prep scale-up of the drug peaks was successful with sufficient resolution of the critical peak pairs to ensure that maximum recovery of pure fractions would be possible. ABBREVIATIONS BA- Benzoic Acid RIS- Risperidone HPLC- High Performance Liquid Chromatography ICH- International Conference of Harmonization DAD-Diode Array Detector KH2PO4 -Pottasium Dihydrogen Phosphate SST-System Suitability Test Tf- Tailing Factor R.S.D.- Relative Standard Deviation REFERENCES [1] Mental Health: Evidence and Research Department of Mental Health and Substance Abuse, World Health Organization Geneva, Mental Health Atlas, 2005, 16 69

[2] World Health Organization (Geneva) & World Federation of Neurology (London), 2004, Atlas: country resources for neurological disorders, ISBN- 92 4 156283 [3] www.who.int/mental_health/mhgap/en/, June 2014. [4] http://www.drugbank.ca/drugs/db00734, June 2015. [5] R. Singh, Journal of Pharmaceutical Education Research, 2013, 4(1), 20-27. [6] ICH Harmonized Triplicate Guideline: Validation of Analytical Procedures: Text and Methodology Q2 (R1), ICH Steering Committee, Step 4 of ICH process, 2005, 25-27. [7] B. K. Sharma, Instrumental Methods of Chemical Analysis, Introduction to Analytical Chemistry, 19 th edition, Goel publishing house, Meerat, India, 2000, 1(4), 200-203. [8 ] R. A. Nash and A. H. An International third edition, 2004, 129, 135-145. [9] CDER, Reviewer Guidance, "Validation of Chromatographic Methods, 1994. [10] J. Avellant, why Quality by Design an Executive s Guide to the FDA s Quality by Design G, Cerulean Associates LLC, 2008. [11] S. Roy, International Journal of Pharmaceutical and Biomedical Research, 2012, 3(2), 100-108, [[12] J Berridge, Q8(R1) Pharmaceutical Development Revision 1, CDER Reviewer Guidance,, 2007, Version 8.1. [13] S. Patil et al, International Journal of Pharmaceutical Quality Assurance, 2013, 4(2); 13-19, 2013. [14] S. Karmarkar, Journal of Chromatographic Science, 2011, Vol. 49, 143-149. [15]Module 3 Quality 3.2.P.2 Pharmaceutical Development, Quality by Design for ANDAs: An Example for Immediate-Release Dosage Forms, Food and Drug Administration, April 2012. [16] Y. Mohammad, Research Journal of Pharmaceutical, Biological and Chemical Sciences, 2000, 1 (2), 121-128. [18] C. Rambabuet. al., Chemical Science Transactions, 2013, 2(1), 41-46. [19]Maalankaet., Acta Poloniae Pharmaceutica and Drug Research, 2009, Vol. 66 (5), 461-470, [20] S. D. Santhosam, Journal For Drugs and Medicines, 2011, 3(1), 29-33. [21] D. Patel, International Journal of Pharmaceutical Sciences Review and Research, 2010, 4(3), 154-162. [22] A. Smith, Der Pharma Chemica, 2010, 2(3), 309-315. [23 ]P. Suthar, International Journal of PharmTech Research, 2009, 1(3), 568-574, 70