Energy and Thermal Comfort Management in a Kindergarten School Building in the South of Portugal in Winter Conditions

Similar documents
ENERGY AND THERMAL COMFORT EVALUATION FOR DIFFERENT PASSIVE SOLUTIONS IN A KINDERGARTEN IN SUMMER CONDITIONS.

Energy and Comfort in School Buildings in the South of Portugal

Indoor comfort and air quality in spaces equipped with eco-ventilation systems

Energy and Comfort in School Buildings in the South of Portugal

REAL-TIME CONTROL OF OCCUPANTS THERMAL COMFORT IN BUILDINGS. Galway, Ireland

Indoor Air 2005, Beijing, China Effectiveness of confluent jets ventilation system for classrooms

Investigation of air quality, comfort parameters and effectiveness for two floor level air supply systems in classrooms

Perception of Thermal Comfort for Naturally Ventilated High School Classrooms in San Rafael, CA

Evaluation methods for indoor environmental quality assessment according to EN15251

Energy and indoor temperature consequences of adaptive thermal comfort standards

ANALYSIS OF ENVELOPE THERMAL BEHAVIOUR THROUGH PARAMETRIC STUDIES. Civil Engineer, PhD, Assistant Professor, Civil Engineering Department (3)

Cost-Benefit Analysis of Dwelling Retrofit Options

125BEPM - Building energy performance modeling. Lecture handouts

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

Assessing thermal comfort of dwellings in summer using EnergyPlus

PERFORMANCE EVALUATION OF TWO AIR DISTRIBUTION SYSTEMS. T Karimipanah 1 and H B Awbi 2

Designing Air-Distribution Systems To Maximize Comfort

SKYLIGHT DESIGN PERFORMANCE EVALUATION METHOD DEVELOPMENT WITH THERMAL AND DAYLIGHT SIMULATION

447 - Thermal Performance of Residential Buildings in Lisbon with Large Glazing Areas

Chapter 7. Passive Solar Contents

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

Buildings with large glazed surfaces: optimization of solar control strategies in relation to the building's thermal inertia

Research of Thermal Comfort for Side Air Supply Pattern in Office

On the performance of confluent jets ventilation system in office space

MODELLING BUOYANCY INDUCED FLOWS OF PASSIVE COOLING SYSTEMS Pedro Correia da Silva 1, Vítor Leal 1 and J. Correia da Silva 2

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

BUILDING DESIGN FOR HOT AND HUMID CLIMATES IMPLICATIONS ON THERMAL COMFORT AND ENERGY EFFICIENCY. Dr Mirek Piechowski 1, Adrian Rowe 1

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

CAMPUS FACILITIES PLANNING BOARD PRESENTATION April 7, KUYKENDALL RENOVATION CFPB PRESENTATION April 7, 2011 modified for RFSOQ, March 23,2012

Findings of Field Survey for Thermal Comfort and Ventilation in US Office Buildings

NUMERICAL SIMULATION OF CAR COCKPIT HEATING DURING WINTER 1

Thermal comfort study of naturally ventilated office

Numerical Investigation on Ventilation Strategy for Laboratories: A Novel Approach to Control Thermal Comfort Using Cooling Panels

Thermal Comfort Measurements in a Hybrid Ventilated Office Room

Prediction of Thermal Comfort. mech14.weebly.com

ADVANCED FAÇADES AND HVAC SYSTEMS: PRELIMINARY RESULTS OF FULL-SCALE MONITORING

FAST EVALUATION OF SUSTAINABLE HEATING AND COOLING STRATEGIES FOR SOLAR HOMES WITH INTEGRATED ENERGY AND CFD MODELING

Thermal comfort recent challenges

Room-side Low-e Coating: As Good As It Sounds?

IMPLEMENTATION OF ANALYTICAL MODELS FOR PASSIVE DOWN-DRAFT EVAPORATIVE COOLING (PDEC) TOWER WITH SPRAY SYSTEMS

Sustainable Designed Air-Conditioned Mosque For Thermal Comfort

Energy simulation of traditional vs. adaptive thermal comfort for two

Comparison between thermal comfort predictive models and subjective responses in Italian university classrooms

Thermal comfort under transient seasonal conditions of a bioclimatic building in Greece

Energy Consumption and Indoor Environment Predicted by a Combination of Computational Fluid Dynamics and Building Energy Performance Simulation

Designing for thermal comfort near a glazed exterior wall. * School of Engineering, Auckland University of Technology, Auckland, New Zealand

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

SOLAR PHOTOVOLTAIC ENERGY

Available online at ScienceDirect. Procedia Engineering 169 (2016 )

ON THE ENERGY CONSUMPTION OF HIGH- AND LOW-LEVEL AIR SUPPLIES

HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya

Thermal Environment evaluation in commercial kitchens

SMART CONTROL FOR NATURAL VENTILATION HOUSE

VARIABILITY OF THERMAL STRATIFICATION IN NATURALLY VENTILATED RESIDENTIAL BUILDINGS. Stephanie Gauthier 1, David Shipworth 1

Allowing for Thermal Comfort in Free-running Buildings in the New European Standard EN15251

Integrated HVAC systems in Central Europe climate

Thermal Control in Buildings by John Straube (updated )

DESIGN AND USE OF RADIANT BARRIERS AS THERMAL INSULATION FOR HIGH INERTIA HOUSES IN TROPICAL CONDITIONS A CASE STUDY

A Field Study of Thermal Comfort in Open-plan Office Buildings during Transition Seasons in Harbin. Yunsong Han 1, 2, Huixuan Sun 1, 2, Cheng Sun 1, 2

SUBJECTIVE AND MEASURED THERMAL COMFORT IN ITALIAN UNIVERSITY CLASSROOMS IN HEATED AND FREE RUNNING CONDITIONS

Optimizing Indoor Environments for Occupant Satisfaction. Presented by: Kelli Goldstone April 2016

Assessment of thermal comfort near a glazed exterior wall

IMPLICATIONS OF CLIMATE CHANGE AND OCCUPANT BEHAVIOUR ON FUTURE ENERGY DEMAND IN A ZERO CARBON HOUSE

Information paper 17. Prepared by: David Clark. book:

Thermal comfort evaluation of natural ventilation mode: case study of a high-rise residential building

Analysis of the Window Side Thermal Environment Formed by Air Barrier. Technique in Winter Conditions and Its Economy

REAL-LIFE OPERATION OF SOLUS SYSTEM: A FOCUS ON THERMAL COMFORT 11 A P R I L D A N VA K D A G E N

Chapter 6. Space heating load

Application of CFD Predictions to Quantify Thermal Comfort for Indoor Environments

Thermal Comfort Evaluation of HDB flats

OVERVIEW TERMS & CONCEPTS PRINCIPLES OF VENTILATION FILTRATION THERMAL COMFORT CONTAMINATION CONTROL CONCEPTS DESIGN TRENDS 02/05/2013

FULL YEAR PERFORMANCE SIMULATION OF A DIRECT-COOLED THERMAL STORAGE ROOF (DCTSR) IN THE MIDWEST

Energy simulation of traditional vs. adaptive thermal comfort for two moderate climate regions Hensen, J.L.M.; Hensen Centnerová, L.

Air distribution and temperature control in classrooms

COMPARISON OF THE STANDARDIZED REQUIREMENTS FOR INDOOR CLIMATE IN OFFICE BUILDINGS

Adaptive thermal comfort explained by PMV

BUILDING INTEGRATED VENTILATION SYSTEMS MODELLING AND DESIGN CHALLENGES

Ventilated Illuminating Wall (VIW): Natural ventilation and daylight experimental analysis on a 1:1 prototype scale model

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland. Research on indoor thermal environment of stilted buildings in Chongqing, China

Effect of energy renovation on thermal sensation and comfort

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Use of a Global Building-HVAC System model for Audit

Optimisation of an HVAC system for energy saving and thermal comfort in a university classroom

carbon-neutral architectural design Pablo La Roche CRC Press Taylor & Francis Croup Boca Raton London NewYork CRC Press is an imprint of the

The applicability of the ISO 7730 (Fanger's comfort model) and the adaptive model of thermal comfort in Jakarta, Indonesia.

Computational Fluid Dynamics and Building Energy Performance Simulation Nielsen, Peter Vilhelm; Tryggvason, T.

Thermal comfort assessment of Danish occupants exposed to warm environments and preferred local air movement

ENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE

THERMAL COMFORT ANALYSIS OF BUILDINGS USING THEORETICAL AND ADAPTIVE MODELS Hélder Silva Almeida

2006 Building Science Press All rights of reproduction in any form reserved.

EFFECTS OF TREES ON THE ROOM TEMPERATURE AND HEAT LOAD OF RESIDENTIAL BUILDING. Tokyo, Japan

Quantifying Comfort to Assist in the Window Selection Process

Investigation and Analysis of Winter Classroom Thermal Environment. In Chongqing

Simulation And Optimization of a Solar Absorption Cooling System Using Evacuated Tube Collectors

An Assessment of Thermal Comfort in Hot and Dry Season (A Case Study of 4 Theaters at Bayero University Kano)

Model-based control through co-simulation for intelligent Building Energy Management Systems design

Performance Investigation of Building Ventilation System by Calculating Comfort Criteria through HVAC Simulation

Assessment of outdoor thermal comfort and its relation to urban geometry

ENERGY-EFFICIENCY IN AIR-CONDITIONED BUILDINGS: AN OVERVIEW

CHAPTER 3. BUILDING THERMAL LOAD ESTIMATION

Transcription:

4th IASME/WSEAS International Conference on ENERGY, ENVIRONMENT, ECOSYSTEMS and SUSTAINABLE DEVELOPMENT (EEESD'8) Algarve, Portugal, June 11-13, 8 Energy and Thermal Comfort Management in a Kindergarten School Building in the South of Portugal in Winter Conditions EUSÉBIO Z. E. CONCEIÇÃO 1, MARGARIDA C. LOPES 1 AND Mª. MANUELA J. R. LÚCIO 2 1 Faculdade de Ciências do Mar e do Ambiente Universidade do Algarve Campus de Gambelas, 85-139 Faro PORTUGAL 2 Agrupamento Vertical Professor Paula Nogueira R. Comunidade Lusíada, 87- Olhão PORTUGAL Abstract: - In this work a numerical model, which simulates the buildings thermal response and evaluates the indoor environment comfort, in transient conditions, is used in the energy and thermal comfort management in a kindergarten school building in the South of Portugal in Winter conditions. After it s validation, this numerical model is applied in the evaluation of the building thermal behavior, using the indoor temperature field, and the occupants thermal comfort levels, using the PMV and PPD indexes. In the numerical model validation, experimental data and numerical values, for the indoor air temperature, are compared. In the experimental tests, for a typical Winter day, the outdoor and indoor environmental variables are measured. In the numerical simulation of the kindergarten school building, the 25 compartments, the 498 building main bodies and the 42 windows glasses, as well as all surrounding main buildings, are considered. The viability to build an indoor greenhouse, used to heat the cooled spaces, and the evolution of indoor thermal comfort level are analyzed. Key-Words: - Kindergarten school building, Numerical simulation, Experimental tests, Building thermal behavior, Energy, Indoor greenhouse, Thermal comfort. 1 Introduction In the Algarve region, in the South of Portugal, it is very important to develop kindergarten school buildings, adapted to this region, that can promote the increase of the occupants comfort conditions, namely the thermal and air quality, as well as to promote the reduction of energy consumption levels for the buildings. In Winter conditions renewable resources, like direct solar radiation, in order to increase the indoor air temperature level, are used. The energy management in this kind of situation, in order to obtain a better thermal comfort field inside a building environment, is frequently analyzed using building thermal behavior numerical models. In [1], as example, a school building thermal response, located in the South of Portugal, in a Winter typical day using a numerical model that simulates the thermal behavior of a building with complex topology and evaluates the indoor air quality, in transient condition, was made. The idea of the study is to reduce the buildings energy consumption and increase the occupants' thermal comfort levels, using the high solar radiation levels disposable in this region. In the first phase the uncomfortable rooms were identified, in the second phase the electric air heating systems with PMV index control were numerically installed and, in the third phase, three air collectors located above the roof area to heat the air to be injected in the uncomfortable rooms were numerically analyzed. In the first phase were verified that, in general, the rooms with windows turned North, the compartments with windows subjected to shading devices and the indoor spaces without windows with low occupation level, presented the highest uncomfortable thermal conditions. The installation of electric air heating systems in uncomfortable spaces promoted good thermal comfort levels. It was verified that using the PMV index control is possible to guarantee high comfort levels with lower energy consumption levels in the heating process. The highest consumption level was verified in the first hours of the day, mainly in compartments with main occupation time verified during break times. In the third phase was verified that the solar air collectors promoted, in the afternoon, acceptable thermal and air quality levels in the considered spaces. In this phase, in order to ISBN: 978-96-6766-71-8 9 ISSN: 179-595

4th IASME/WSEAS International Conference on ENERGY, ENVIRONMENT, ECOSYSTEMS and SUSTAINABLE DEVELOPMENT (EEESD'8) Algarve, Portugal, June 11-13, 8 promote simultaneously thermal and air quality good levels, was verified that the uncomfortable occupied spaces are ventilated and heated using warm air from the collector, the comfortable or lightly comfortable spaces are ventilated and heated using lightly warm air from the corridor and the small comfortable occupied spaces are ventilated using clean air coming directly from the outdoor environment. In order to evaluate the thermal comfort level in moderate environments equipped with airconditioning systems, either in cold or in warm climates, during Winter or Summer, the PMV (Predicted Mean Vote) and the PPD (Predicted Percentage of Dissatisfied) indexes are used in [2], [3] and [4]. For acceptable thermal comfort conditions, the [4] defines three comfort categories (A, B and C), establishing limits for PMV and PPD indexes. This classification allows the selection a priori of one thermal environment according to the required demands. In this work a numerical model, that simulates the buildings thermal response and evaluates the indoor environment comfort, in transient conditions, is used in the energy and thermal comfort management in a kindergarten school building in the South of Portugal in Winter conditions. The work is divided in three parts: in the first one the numerical values are compared with the experimental measured data, in the second one the indoor temperature field are used to identify potential spaces used as indoor greenhouse with capacity to use the solar radiation in the indoor air heating, finally, in the third one the indoor thermal comfort level, using the PMV and PPD index, that occupants are subjected, is evaluated. 2 Numerical Model The multi-nodal buildings thermal behavior model, which operates in transient conditions, is based in energy and mass balance integral equations (see [5], [6] and [7]). The energy balance integral equations are developed for: - the air (inside the several compartments and ducts system); - the different windows glasses; - the interior bodies (located inside the several spaces); - the different layers of buildings main bodies and ducts system. The mass balance integral equations are developed for: - the water vapor (inside the several spaces, ducts system and in the interior surfaces); - the air contaminants (inside the several spaces and ducts system). In the resolution of this equations system the Runge- Kutta-Fehlberg method with error control is used. The model considers the conductive, convective, radiative and mass transfer phenomena: - the conduction is verified in the building main bodies (doors, ceiling, ground, walls, etc.) and ducts system (fluid transport) layers; - in convection the natural, forced and mixed phenomena are considered; - in the radiation, verified inside and outside the building, the short-wave (the real distribution of direct solar radiation in external and internal surfaces) and long-wave (heat exchanges between the buildings external surfaces and the surrounding surfaces as well as among the internal surfaces of each space) phenomena are considered. In radiative calculus the shading effect caused by the surrounding surfaces and by the internal surfaces is considered. The input data in the software are: - the buildings geometry (introduced in a threedimensional design software); - the boundary conditions; - the materials thermal proprieties and other conditions (like the outdoor environmental and geographical conditions, the initial conditions, the several heat and mass load, the occupation cycle, the occupant s clothing and activity levels and the air ventilation topologies). 3 Building Simplified Geometry In the analyzed kindergarten school building (see Figure 1), divided in 24 compartments (see identification in figure 2), 498 building main bodies and 42 windows glasses are considered. This building, located in Olhão, has three classrooms, for 3, 4 and 5 years old children, and other spaces for offices, administrative, WC, teachers and nonteachers staff and meeting room. Figure 1. Grid generation in the kindergarten school building and surrounding buildings. This geometry is based in the Jardim-de-Infância n.º 4 de Olhão. ISBN: 978-96-6766-71-8 91 ISSN: 179-595

4th IASME/WSEAS International Conference on ENERGY, ENVIRONMENT, ECOSYSTEMS and SUSTAINABLE DEVELOPMENT (EEESD'8) Algarve, Portugal, June 11-13, 8 In Figures 1 the grid generation used in the numerical simulation of the kindergarten school building is presented. This numerical grid, used in the internal and external direct solar radiation determination, was spaced 3 cm in both directions. outdoor air temperature and relative humidity) and in the validation of the indoor air temperatures for three occupied strategic rooms: numbers 3, 1 and (figure 2) were measured in the typical Winter, the 27 th January 7. All measured data were stored in four dataloggers during 24 hours with an acquisition rate of 1 sample per minute. In figures 3, 4 and 5 the evolution of the measured and calculated indoor air temperature, are presented. The figures 3 are associated to compartment number 3, the figure 4 are associated to compartment number 1 and figure 5 are associated to compartment number. In these figures the points are associated to experimental data, while the lines are associated to numerical values. Numerical Experimental Figure 2. Identification of the indoor compartment of the kindergarten school building. 4 Results In this study the software that simulates the buildings thermal response, with complex topology, in transient conditions, and evaluates the indoor thermal comfort and indoor air quality levels, is used. This software was validated in Winter [6] and Summer [7] conditions, in school buildings with complex topology. Nevertheless, in this work, before the evaluation of building thermal response and occupants thermal comfort conditions, the software is also validated considering the surrounding buildings. In this numerical model validation the doors and windows were closed, the internal curtains were open, the air-conditioning systems were off, the occupation is not considered and the internal radiative heat exchanges were also not considered. The air mean renovation values inside each compartment by infiltration were experimentally obtained, in several compartments, using the tracer gas concentration method. In the school buildings numerical simulation, in order to evaluate the real building thermal inertia, the previous 5 days were also simulated. The experimental test, used in the validation phase, was made in a day without external wind. Figure 3. Evolution of air temperature, measured and calculated, inside the compartment number 3. Numerical Experimental Figure 4. Evolution of air temperature, measured and calculated, inside the compartment number 1. Numerical Experimental 4.1 Validation tests The experimental data used in the numerical model as inputs of the outdoor environmental variables (the Figure 5. Evolution of air temperature, measured and calculated, inside the compartment number. ISBN: 978-96-6766-71-8 92 ISSN: 179-595

4th IASME/WSEAS International Conference on ENERGY, ENVIRONMENT, ECOSYSTEMS and SUSTAINABLE DEVELOPMENT (EEESD'8) Algarve, Portugal, June 11-13, 8 Classroom number 3 is equipped with windows turned South, the playground number 1 is equipped with windows turned to East and classroom number is equipped with windows turned West and North. In accordance to the obtained results, in the previous figures, it is possible to conclude that the numerical model reproduces the experimental indoor air temperatures behavior. In general, the difference between numerical and experimental indoor air temperature values is lower than 2.5 ºC. Some discrepancies verified between the numerical values and the experimental results, are associated to: - the North classroom windows curtains, that were partially closed during the experimental data assessment, creating an obstacle to the radiative exchanges, verified in the numerical overdimensioned values for this classrooms (compartments ); - the mean value for the air renovation rate experimentally obtained in some spaces, presents local differences; - the building interior bodies, that can influence the building thermal inertia, were not considered; - the ceiling, in contact with the outdoor environment, presents a great solar load. Thus, small discrepancies in the identification of the material are reflected in the indoor air temperature calculation; - the small differences in the evaluation of the surrounding buildings external geometry, are reflected in the kindergarten school building external surfaces solar radiation; - the grid generation is spaced 3 cm in both directions. The reduction of this distance, with consequently increase of the calculation time, allows better shading effects and solar radiation calculations; - the numerical model used to determine the external solar radiation, with and without cloudy sky. In this simulation the best model for the analyzed day was used, nevertheless, these kinds of models may cause some errors in solar radiation calculations; - the outdoor environmental variables, used as input data, measured in the outdoor environment, due to the building dimensions and complexity. 4.2 Building thermal behavior The evolution of indoor air temperature for the hall, corridors and playground area (compartments 2, 1 and 25), the classrooms (compartments 3, 13 and ) and the offices (compartments 7, 11 and 23) are presented, respectively, in figure 6, 7 and 8. 3 28 26 24 Tar-2 Tar-1 Tar-25 Figure 6. Evolution of air temperature calculated inside compartments number 2, 1 and 25. 21 19 17 15 Tar-3 Tar-13 Tar- Figure 7. Evolution of air temperature calculated inside compartments number 3, 13 and. 21 19 17 15 Tar-7 Tar-11 Tar-23 Figure 8. Evolution of air temperature calculated inside compartments number 7, 11 and 23. In accordance to the figures 6, 7 and 8, it s possible to conclude that: - the classrooms with windows turned to North (compartments 13 and ) had the lowest indoor air temperature values, while the hall (compartment 2) presented the highest indoor air temperature values; - the hall, with high window area turned South and West, in accordance to the highest indoor air temperature verified, can be used as indoor greenhouse. The warm air can be used to heat the indoor air temperature of the classroom with windows turned North (compartments 13 and ). ISBN: 978-96-6766-71-8 93 ISSN: 179-595

4th IASME/WSEAS International Conference on ENERGY, ENVIRONMENT, ECOSYSTEMS and SUSTAINABLE DEVELOPMENT (EEESD'8) Algarve, Portugal, June 11-13, 8 4.3 Occupants thermal comfort The evolution of thermal comfort levels for the hall, corridors and playground area (compartments 2, 1 and 25), the classrooms (compartments 3, 13 and ) and the offices (compartments 7, 11 and 23) are presented in figures 9 to. In figures 9, 11 and 13 the PPD evaluation is presented, while in figures 1, 12 and the PMV evaluation is presented. clothing and activity level. In this calculus the Fanger model [2] is used. The PPD index is correlated with the PMV index using the Fanger model [2]. 1.5 1.5 PMV-3 PMV-13 PMV- 4 3 PPD-2 PPD-1 PPD-25 PMV -.5-1 PPD (%) 1-1.5 Figure 12. Evolution of PMV index calculated inside compartments numbers 3, 13 and. Figure 9. Evolution of PPD index calculated inside compartments numbers 2, 1 and 25. 1.5 1 PMV-2 PMV-1 PMV-25 PPD (%) 4 3 1 PPD-7 PPD-11 PPD-23 PMV.5 -.5-1 Figure 13. Evolution of PPD index calculated inside compartments numbers 2, 1 and 25. -1.5 Figure 1. Evolution of PMV index calculated inside compartments numbers 2, 1 and 25. 1.5 1.5 PMV-7 PMV-11 PMV-23 4 3 PPD-3 PPD-13 PPD- PMV -.5-1 PPD (%) 1-1.5 Figure. Evolution of PMV index calculated inside compartments numbers 2, 1 and 25. Figure 11. Evolution of PPD index calculated inside compartments numbers 3, 13 and. The PMV index is calculated, by the software, for each space, using the numerical values of the indoor air temperature, air velocity (obtained through the air renovation and recycled air mass flow), air relative humidity and mean radiant temperature (obtained through the mean value of the compartments surrounding surfaces temperatures), for a pre-defined In accordance to the figures 9 to, it s possible to conclude that: - the hall is thermally uncomfortable, by positive PMV values and the corridor and the playground are thermally comfortable in the afternoon; - the classrooms with window turned North are most uncomfortable than the classroom with windows turned to South; - the offices are thermally comfortable in the afternoon, nevertheless their occupation during the day isn t continuous. ISBN: 978-96-6766-71-8 94 ISSN: 179-595

4th IASME/WSEAS International Conference on ENERGY, ENVIRONMENT, ECOSYSTEMS and SUSTAINABLE DEVELOPMENT (EEESD'8) Algarve, Portugal, June 11-13, 8 5 Conclusion In this work a numerical model, that simulates the buildings thermal response and evaluates the indoor thermal comfort and air quality, in transient conditions, is used in the energy and thermal comfort management in a kindergarten school building in the South of Portugal in Winter conditions. The work is divided in three parts: in the first one the numerical values are compared to the experimental measured data, in the second one the indoor temperature field is used to identify potential spaces used as indoor greenhouse and in the third one the indoor thermal comfort level, using the PMV and PPD indexes, that occupants are subjected, is evaluated. The validation of the numerical model, being considered the kindergarten school building and the surrounding buildings, shows good agreement between the numerical values and the experimental data. The higher difference, in general, doesn t exceed the 2.5 ºC. It was verified that the classrooms with window turned North present the lowest indoor air temperature values, while the hall, with significant area of glasses windows turned South and West, the highest indoor air temperature values. Thus, is suggested to consider the hall as greenhouse used to warm the air to be used in the classrooms with window turned North. It is suggested to use a horizontal duct or the corridor, to transport this warm air from the greenhouse to the classrooms with windows turned North. It is also suggested to analyze, in future simulations, this topic. The classrooms with windows turned North are thermally uncomfortable, nevertheless the comfort level in the afternoon in the classroom with windows turned South are in accord to the standards. It is suggested to consider the presence of occupants and the introduction of ventilation in future simulations. The first will increase the indoor air temperature, while the second, if the air came from the outdoor environment without heated, will decrease the indoor air temperature. 6 Acknowledgement This research activity is being developed inside a project financed by the City Council of Olhão. This research activity is being also developed inside a project approved and financed by the Portuguese Foundation for Science and Technology and POCI 1, sponsored by the European Community Fund FEDER. References: [1] Conceição, E. Z. E. and Lúcio. M.ª M. J. R., Thermal Study of School Buildings in Winter Conditions", Building and Environment, Volume 43, No. 5, May 8, pp. 782-792. [2] Fanger, P. O., Thermal Comfort, Danish Technical Press, 197. [3] ISO 773, Moderate Thermal Environments - Determination of the PMV and PPD Indices and Specification of the Conditions for Thermal Comfort. International Standard, 1994. [4] CR 1752, Ventilation for Buildings: Design Criteria for the Indoor Environment, Comité Européen de Normalisation, 1998. [5] Conceição, E. Z. E., Numerical Simulation of Buildings Thermal Behaviour and Human Thermal Comfort Multi-node Models, In Proceedings of the 8th International IBPSA Conference - Building Simulation 3. Eindhoven, Vol. 1, pp. 7-234. [6] Conceição, E. Z. E., Silva, A. and Lúcio. Mª M. J. R., Numerical Study of Thermal Response of School Buildings in Winter Conditions, In Proceedings of the 9th Conference on Air Distribution in Rooms - Roomvent 4, Coimbra. [7] Conceição, E. Z. E. and Lúcio. M.ª M. J. R., Numerical Study of Thermal Response of School Buildings in Summer Conditions, In Proceedings of the Healthy Buildings 6, Lisbon, Vol. 3, pp. 195-. ISBN: 978-96-6766-71-8 95 ISSN: 179-595