FEATURES APPLICATIONS. Technical data sheet SSW - STEEL STRONG-WALL FOR TIMBER FRAME RACKING RESISTANCE.

Similar documents
Racking Solutions for Timber Framed Buildings T-RS-UK Edition. +44 (0)

FEATURES TECHNICAL DATA. Technical data sheet SSWT - STEEL STRONG-WALL FOR TIMBER FRAME RACKING RESISTANCE

SIMPSON STRONG-TIE BOTTOM PLATE ANCHOR SOLUTIONS. Product. Scope. Building Regulations. Appraisal No. 983 [2018] Appraisal No.

8.8 M10/15x90 50Nm. Zinc plated. Mechanically galvanised. PSA anchor. heavy duty vibration resistant removable

R-CAS-V Spin-In Capsule with Threaded Rods

Injection Adhesive VM-PY

Concrete Screw-Anchors

SVM-PSC Polyester resin for use in concrete

System Components. Grades. General Information Installation Information

Concrete screw BSZ Steel/steel zinc flake coated

SpaTec Plus. Mechanical Anchoring 27.1 SAFETY ANCHORS 27.1 GENERAL INFORMATION

HFX Adhesive Anchor Adhesive Anchoring Systems

fischer Test Report Fixing Tests for

Injection System VMZ. Injection System for cracked and non-cracked concrete. Conical Stud VMZ-A. Cartridge VMZ 150

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry

Assembly and users manual. Pallet racking Alfa

R-CAS-V Spin-In Capsule with Threaded Rods

CALIFORNIA ERIC GARCETTI MAYOR

SUPERPLUS M8-M16. The undercut fixing system that does not require a special setting tool. FUNCTION BENEFITS

Blue-Tip SCREW-BOLT. Ratchet teeth locks head against fixture. Reverse parabolic threads privide high load capacity

System Components. Grades. General Information. Installation Information Design Information Material Information Ordering Information

EJOT Chemical Anchoring Systems. High strength anchoring of threaded resin studs into masonry blocks, cracked and non-cracked concrete

fischer fixing compass Cracked concrete.

fischer Test Report Fixing Tests for Bison Hollow Core Slabs

Internal Partitions - Timber Studs Internal Partitions - Steel Stud

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785)

Materials Polyester Resin Anchors: Carbon Steel grade 5.8 Stainless Steel: AISI 316

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

MASONRY ANCHORS AND CONNECTORS May 6, 2014

CHEMICAL /4" 3/8" to 5/8" /8" 3/4" to 1-1/4" 1 10

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

Hilti, Inc South 122 nd East Avenue Tulsa, OK

REPORT No SIMPSON STRONG-TIE AT-HP

TruBolt A4 316 SS. Cracked Concrete - Mechanical Anchoring 47.1 CRACKED CONCRETE - STUD ANCHOR 47.1 GENERAL INFORMATION

Galvanised Longspan Shelving

HLC. Hex head nut with pressed-on washer HLC-H. Bolt version with washer HLC-L. Torx round head HLC-SK. Torx Counter sunk head HLC-EC

Used for Florida State Wide Product Approval #

Trutek TCM380 PRO. Trutek Fasteners Polska Al. Krakowska 55 Sekocin nowy Rasxyn Poland T:

Index. Clawbolt Anchor Tygabolt Anchor. Xbolt Anchor. Dropin Anchor & Tool. Nail-in Anchor Suspension Anchor


NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

Raised Basement. Mechanical Installation Guide

INSTALLING A POUR-IN-PLACE DOCK LEVELER (EH & RR)

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

EPCON C6. Chemical Anchoring - Anchor Studs 9.1. Principal Applications CHEMICAL INJECTION ANCHORING 9.1 GENERAL INFORMATION

Adjustable Suspension Hanger Technical Datasheet

SECTION WOOD FRAMING. A. Includes But Not Limited To: 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

rondo accessories CONTENTS:

BETTER BY DESIGN BRICK SLIP MASONRY SUPPORT INSTALLATION INSTRUCTIONS. igmasonrysupport.com

Fosroc Lokfix E75. High performance pure epoxy 3:1 resin cartridge system, for anchoring reinforcement and fixings into a variety of substrates.

R-KEM II with Threaded Rods for Masonry

HOLDOWN & STRAP SCHEDULE

Note on the assessment:

R-KEM II with Threaded Rods for Masonry

SOUDAFIX VE400-SF. Temperature -10 C (1) -5 C 0 C 5 C 10 C 20 C 30 C 35 C 40 C

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Mapefix PE Wall. Chemical anchor for masonry and light loads

SpaTec Plus. Cracked Concrete - Mechanical Anchoring 46.1 CRACKED CONCRETE - SAFETY ANCHORS 46.1 GENERAL INFORMATION

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

US Pool Lift Model #114 (Independence) Installation Guide

Residential Wall Panel Installation

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Construction. Universal anchoring adhesive. Product Description 1 1/7. Product Data Sheet Edition _1 Sika AnchorFix -S

TILT-UP LIFTING PRODUCTS

The following excerpt are pages from the North American Anchor Fastening Technical Guide, 2011.

DOMESTIC WEDGE ANCHOR

WERCS AnkaScrew. Mechanical Anchoring Principal Applications SCREW IN ANCHORS 30.1 GENERAL INFORMATION. Product

(800) (562) A Subsidiary of the International Code Council

V420+ Hybrid Vinylester Resin

TP EA. Product Description. Properties and Benefits. Applications. Reaction Resin Mortar Based on Epoxy Acrylate. Approvals / Certificates:

Injection System VMU plus

MKT Fixing. JAM The Professional Standard. Quality Management. Environmental Management. Energy Management

CODE TYPE LENGTH BOX per/100 BM01 ST BM02 ST BM03 ST BM04 ST POA

STRUCTURAL STEEL FRAMING

Hilti, Inc South 122 nd East Avenue Tulsa, OK

TECHNICAL MANUAL. HPKM Column Shoe Reliable Bolted Column Connections. Version: PEIKKO GROUP ACI-M 01/2017 Designed according to ACI 318M-11

Installation Guidelines for Flygt Pumps Pump Anchoring Recommendations

ULTRAPLUS M12-M36. The undercut anchor for exceptionally high loads in cracked and non-cracked concrete also for shock and seismic loads.

HIT-ICE INJECTION MORTAR. Technical Datasheet Update: Jun-18

Design of Column Base Plates

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal May 1, 2015

Schöck Isokorb type KS

2012 VIRGINIA TECH SCHEDULE OF SPECIAL INSPECTIONS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Frame fixing SXS-F US

The high-performance frame fixing with SX-technology VERSIONS. zinc-plated steel stainless steel BUILDING MATERIALS

Building Division Informational Handout

SHEAR BRACE. Featuring ilevel Shear Braces for Engineered and Prescriptive Applications iLevel8 (

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17

TECHNICAL DATA SHEET SIKA ANCHORFIX-1 GREY 300ML (6's)

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

MECHANICAL ANCHORING. Specifi ers Anchoring Resource Book Book 2.3 of 3 MECHANICAL ANCHORING

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

XHBN.FF-D Joint Systems. Joint Systems. System No. FF-D-3008

Transcription:

The Steel Strong-Wall is a corrugated steel panel which is designed to be fixed directly to the concrete foundations of a building, within the external or internal wall, via a bolted connection. FEATURES Material Steel Strong-Wall: Galvanised mild steel - Z275. AT-HP adhesive: Strene free, methacylate resin. Threaded Rods: Grade 8.8 carbon steel, zinc plated. Nuts and washers: Carbojn steel, zinc plated. Screws: SDS25112. APPLICATIONS Applications The Steel Strong-Wall can be used in conjunction with either 89mm or 140mm deep stud walls (and any thickness in between). Around openings such as garages, patio doors and bay windows. Narrow piers Internal walls External walls 1/5

TECHNICAL DATA Product Range & Performance Values For BS Design Methods (Height (B) Range 1900mm - mm) References SSW300 300 SSW450 450 SSW600 600 Anchor Loads at Dimensions [mm] Anchors Fasteners to Top Rail Permissible loads [kn] Racking Loads [kn] Width (A) Height (B) Depth (C) Qty Specification Qty Specification Racking Axial Tension Shear R b 89 2 M20 x 210 4 Ø6.35 x 89 1.75 15.00 89 2 M24 x 210 10 Ø6.35 x 89 6.00 22.50 89 2 M24 x 210 14 Ø6.35 x 89 10.50 30.00 T = 7.697 T = 5.297 T = 2.812 Product Range & Performance Values For BS Design Methods (Height (B) Range 2201mm - mm) References SSW300 300 SSW450 450 SSW600 600 Anchor Loads at Dimensions [mm] Anchors Fasteners to Top Rail Permissible loads [kn] Racking Loads [kn] Width (A) Height (B) Depth (C) Qty Specification Qty Specification Racking Axial Tension Shear R b 89 2 M20 x 210 4 Ø6.35 x 89 1.50 15.00 89 2 M24 x 210 10 Ø6.35 x 89 5.50 22.50 89 2 M24 x 210 14 Ø6.35 x 89 9.50 30.00 T = 5.360 T = 2.704 T = 3.722 2/5

Table Notes: 1. Fasteners are supplied with Steel Strong-Wall panel - Reference SDS25312. 2. R b is the test racking resistance determined from tests carried out in accordance to BS EN 594:2011 3. It is the responsibility of the building engineer/designer to ensure the foundation and hold down anchors can take the applied Tension and Compression loads. 4. F refers to applied racking load 5. Axial loads have been determined with corresponding maximum racking load 3/5

INSTALLATION Benefits Available in three widths: 300mm, 450mm and 600mm. Available height ranges: 1900mm to mm. At only 89mm wide, it can be fitted into standard 89mm and 140mm deep timber frame panels. All fixings and adhesives required for installation are included. General Information The Steel-Strong-Wall should be fixed directly to the concrete foundation. DO NOT sit the Steel Strong-Wall on a timber sole plate. A DPC is required between the Steel Strong-Wall panel and the concrete foundation. The concrete foundation should be designed by the engineer repsonsible for the structure to accommodate the hold down anchors and resist the applied loads. Equipment Required 1 off 22mm (SSW300) or 28mm (SSW450/SSW600) masonry drill, min. 300mm long. 1 off Dust Brush (item code BR17/30).* 1 off Dust Pump (item code PUMP).* 1 off Resin Dispensing Gun (item code DT380).* 1 off 30mm (SSW300) or 36mm (SSW450/SSW600) A/F, Long Length Socket 1 off Torque Wrench (min. capacity 150Nm (SSW300) or 200Nm (SSW450/SSW600). 1 off SDS 1/4 Hex Drive (SDSD3/8-RB).* * Available from Simpson Strong-Tie, call 01827 255600 for prices. Installation 1a - Position the Steel Strong-Wall on top of the foundations in the required position, ensuring the correct orientation of the wall, with the fixing holes facing internally. Mark the foundation through the holes. 1b - Drill vertical holes to the stated diameter and depth: SSW300 = Ø22mm x 160mm SSW450 & SSW600 = Ø28mm x 160mm 1c - Ensure the holes are cleaned thoroughly. 1d - Install the anchor bolts supplied: AT-HP resin with M20 X 210 threaded rod for SSW300 and M24 X 210 threaded rod for SSW450 and SSW600. 2a - Position the Steel Strong-Wall over the anchor bolt rods and level by using steel shims and structural grout if required. Plumb and where necessary, provide temporary bracing, which can be adjacent timber frame panels if already installed. 2b - Install nuts and washers and tighten by hand. Once the AT-HP resin has cured (see cartridge label for cure times) tighten the nut to the recommended torque (M20: 150 Nm torque, using torque wrench with a 30mm socket. M24: 200 Nm torque, 36mm socket). Do not over-tighten nuts as this may lead to premature failure. 2c - Attach vertical timber studs to both sides of the Steel Strong-Wall using the short SDS screws provided. Note: Where necessary to aid levelling of the wall, steel shims are available to order in widths 300, 450 and 600mm and thicknesses 1, 2 and 3.5mm. Contact Simpson Strong-Tie for details. 4/5

3a - The Steel Strong-Wall can be secured to the adjacent timber frame wall panels using SDW22300 screws (not supplied), installed from the timber frame side as shown in fig. 3a. the spacing of the SDW screws is to be determined by the engineer responsible for the design structure. Lateral Capacity of SDW22300 Screw: BS 5268: 0.9kN (short term) Based on 38mm thick C16 timber frame and 38mm thick Steel Strong-Wall stud. Alternate fastening specification shall be in accordance to engineers instructions. 4a - Connect the top of the Steel Strong-Wall to the timber frame structure through the pre-drilled holes in the top plate with the long SDS screws provided. If required, as a height makeup piece, a single solid timber packer (typically LVL) should be inserted between the top of the Steel Strong-Wall and the timber frame structure. 4b - Install the head binder over timber frame and the Steel Strong-Wall. 4c - Install insulation on the outer face of the Steel Strong-Wall panel and close off the panel by installing sheathing to the face of the timber studs - thus maintaining continuity in the timber frame construction.sheathing to be installed with fasteners in accordance with engineers instructions. Steel levelling shims Threaded rods (included) installed into concrete Threaded rod nut fixing Strong-Wall into concrete. Please note: timber studs are not included with the system ig. 3a: SDS screws (supplied) into timber studs (not supplied) Steel Strong- Wall installation example Strip foundations with ground supported floor Strip foundations with suspended floor Trench fill foundations with ground supported floor Raft foundations and floor Strip or trench fill foundations with precast concrete beam and block floor 5/5