Cantilevered Rail System

Similar documents
Installation and Maintenance Manual for EMH Freestanding Workstation Jib Cranes

LEGACY REPORT ER-5608* Reissued February 1, Legacy report on the 1997 Uniform Building Code

Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas

Site Preparation... 2

Foundation Specifications

Midwest Roadside Safety Facility

Concrete Inserts. B Adjustable Metal Deck Ceiling Bolt

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code

(800) (562) A Subsidiary of the International Code Council

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms

HANDSET WALL FORM. Handset Wall Form. Quick Assembly - can be built using only a hammer. Reduced weight increases productivity

Fig Beam Clamp Retaining Strap (B-Line B3367)

HFX Adhesive Anchor Adhesive Anchoring Systems

xiii Preface to the Fifth Edition Preface to the Second Edition Factors for Conversion to SI Units of

Code Compliance Research Report CCRR-0118

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 International Residential Code

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

Freestanding Workstation Steel Bridge Crane

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

Seismic Restraints. Cent-R-Rail Supplement* SYSTEMS THAT MAKE SENSE

DOMESTIC WEDGE ANCHOR

Projector mounts. CMA115 6 (152 mm) CEILING PLATES. concrete. vaulted. CMA330 8 (203 mm) CMA700 6 (152 mm)

Large cable sizes stronger than pipe/strut

STRUCTURAL STEEL FRAMING

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

DDI + (DECK INSERT) Threaded Insert for Metal Deck

DDI + (DECK INSERT) Threaded Insert for Metal Deck

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Testing of the Retrofitted T102R Bridge Railing

Manufactured decking (composite) may be used when approved by the building department

Guidelines for the Engineer & Designer

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.

GUIDE TO PROPER INSTALLATION AND USE OF CANTILEVER RACKS

Smarter. Safer. Leaner.

Instructions for the use of the Link 4 Pallet Rack Lifter (PRL) model 5000

Heartland Perma-Column 1841 E 1450 Rd. Lawrence, KS (785)

Fig. 1 - Standard Clevis Hanger

A GENERAL INSTALLATION GUIDE FOR RIDG-U-RAK DRIVE-IN / DRIVE-THRU STORAGE SYSTEMS IG-DI-1

Typical Deck Details Based on the 2009 International Residential Code (Designed and Printed August 2010)

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SRS-02 NEW SEISMIC RESTRAINTS. Multi-Directional Bracing For Electrical Conduit, Cable Tray And Mechanical Piping Systems SYSTEMS THAT MAKE SENSE

SECTION VIBRATION ISOLATION

Atlas Column Forms COLUMN FORM SYSTEMS MULTI-CHANNEL AL-SPEED

The following excerpt are pages from the North American Product Technical Guide, Volume 2: Anchor Fastening, Edition 16.

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.

Steel Forming System BROCHURE. A durable, all-steel forming system that is ideal for pier caps and self-spanning applications.

Tables with Allowable ASD Seismic Values For Design at R = 6.5. Special Moment Frame MF1-12

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

DIVISION 20 GENERAL SECTIONS FOR PLUMBING, FIRE SUPPRESSION & HVAC SECTION VIBRATION ISOLATORS

CITY OF LOS ANGELES CALIFORNIA

WINSAFE Corp. OPERATING INSTRUCTIONS SUPERMOD MODULAR PLATFORMS CUSTOM LARGE AREA PLATFORMS SUPER DECK MODULAR PLATFORMS BOILERMOD MODULAR PLATFORMS

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

STANDARDIZED STRUCTURES

Deck Design Guide. 67 Sharp Road, Brighton, Ontario P.O. Box 189 K0K 1H0 Tel: Fax: Web:

the varying quality in existing substrates of older buildings. Be sure to specify the following performance criteria as a minimum.

TRAFFIC DIRECTION FOR RAIL LAP AS SHOWN (SEE NOTE 7) "SPLICE BOLT" WITH NUT MIDWEST GUARDRAIL SYSTEM (STANDARD AND REDUCED POST SPACING)

BRANZ FACTS RESILIENT NON-STRUCTURAL ELEMENTS SEISMICALLY RESILIENT NON-STRUCTURAL ELEMENTS # 3. Restraint systems

ERS2010 ERSW2010. Users Manual. Seismic Restraint System

Hilti, Inc South 122 nd East Avenue Tulsa, OK

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

FEATURES APPLICATIONS. Technical data sheet SSW - STEEL STRONG-WALL FOR TIMBER FRAME RACKING RESISTANCE.

600 SERIES FOUNDATIONLESS JIB CRANE MANUAL ADDENDUM

Specialty Applications. for Keystone Walls

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

*Corrected, April 2001

SHEAR BRACE. Featuring ilevel Shear Braces for Engineered and Prescriptive Applications iLevel8 (

STRUT METAL FRAMING SYSTEMS

Interior Hangers. Application

PATHWAYS FOR COMMUNICATIONS SYSTEMS

Seismic Installation Manual

Alu-Track Ceiling Mounted Workstation Aluminum Bridge Crane

City of Winnipeg BASES, HANGERS AND SUPPORTS Section NEWPCC - Pump Well Isolation Page 1 of 6 Tender No June 2003

INSTALLATION MANUAL. All Types F Series Rev G


Seismic Installation Manual

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

CITY OF MOUNT DORA LIFT STATION CHAINLINK FENCE AND GATE SPECIFICATIONS

BRIDGE GIRDERS TECHNICAL GUIDE

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

Power-Bolt+ Heavy Duty Sleeve Anchor

STANDARD RESIDENTIAL DECK DETAILS

Seismic Installation Manual

.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM)

Structural Cantilever Installation Manual

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES

FlowCell. Carton Flow Track. The Patented, Original Full-Width Roller Carton Flow Track SPAN-TRACK

PREFABRICATED STEEL TRUSS SPECIFICATIONS

High Strength Epoxy Tested in Accordance with ICC-ES AC308

REPORT HOLDER: MITEK USA, INC. EVALUATION SUBJECT:

TOWN OF BRADFORD WEST GWILLIMBURY DECK PACKAGE

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

REPORT HOLDER: GLASS VICE HOLDINGS LTD. POST OFFICE BOX MAIRANGI BAY, AUCKLAND 0754 NEW ZEALAND EVALUATION SUBJECT:

Com-Tray. Under Floor

INSTRUCTIONS FOR ASSEMBLING NEBS FLOODED RACKS

Beam Clamps. B303-B309 - Beam Clamps. Fig. B321 - Series Beam Clamps. Size Range: 1 /4"-20 thru 5 /8"-11 rod

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Transcription:

Knight Global's Cantilevered Rail Systems are designed to eliminate the need for a four post floor structure system. It provides an alternative to workstations with minimal floor space. A wide range of options are available with each system to meet all your specific engineering and application requirements. A Knight Representative will assist you in selecting and developing alternatives when designing your rail system. Features Maximum Column Height: 17 ft. [5181mm]. Maximum Beam Length: 23 ft. [7010mm]. Rigid End Trucks to prevent skewing of the bridge and for precise loading and unloading operations. End-Caps with Shocks to absorb the bridge hitting the end of the rail. Extended Stack Hangers with 1.5 in. [38mm] of vertical adjustment in 0.25 in. [6mm] increments. Sway Cables with turnbuckles for adjustment. Integrated beam pad eyes to secure safety and lateral sway cables. Beam pad eyes assist in the lifting of the beam for assembly of the rail system. Options Additional columns to minimize deflection. Extended Runways over 27 ft. [8230mm] - Requires Runway Rail Splice kit. Mid Rail Stops. Dual Cantilevered Rail System Configuration. Offset Three Post Cantilevered Rail System Configuration. For more information, please contact a Knight Global representative.

Maximum Two Post Cantilever Rail System Footprint 28 ft. [8534mm] Column Width 3 ft. sq. [914mm] 25 ft.- 3 in. [7696mm] 20 ft. [6096mm] Runway Centers 25 ft. [7620mm] Beam Centers 1 ft. - 10.75 in. [578mm] 23 ft. [7010mm] Beam Length Rigid End Trucks 2 ft. - 8.5 in. [826mm] Without Backer Wide Flange Beam STACK UP 3 ft. - 1.25 in. [946mm] With 6 Backer 3 ft. - 3.50 in. [1003mm] With 8 Backer 17 ft. [5182mm] Max. Column Height 20 ft. [6096mm] Runway Centers 22 ft. [6706mm] Bridge

Column Anchoring 36 in. sq. [914mm] 16 in. [406mm] 16x 1.0 34 in. [863mm] Typ. 26 in. [660mm] Typ. 18 in. [457mm] Typ. 12 in. [304mm] 10 in. [254mm] Typ. 2.0 in. [50mm] Typ..5 in. [12mm] Wall Hilti #HIT-200-A Chemical Floor Anchor (Adhesive Anchoring System) Anchor Rods: HIT-Z, 3/4 in. Dia. 1.5 in. [38mm] Plate Thickness 9.75 in. [248mm] Rod Length 6.5 in. - 6.75 in. [165mm-171mm] Embedded Depth 8.0 in. [203mm] Min. Concrete Depth MINIMUM CONCRETE RECOMMENDATIONS FOR CANTILEVER FLOOR POST INSTALLATION HILTI #HIT 200-A: CHEMICAL FLOOR ANCHOR (ADHESIVE SYSTEM). ANCHOR RODS: HIT-Z: 0 3/4 X 9 3/4 LG. EMBEDDED DEPTH OF ANCHORS IN CONCRETE MUST BE 6 1/2-6 3/4. (DEPTH OF HOLES MUST NOT EXCEED 6 3/4 ) MINIMUM 8 CONCRETE THICKNESS. MINIMUM 3000 PSI CONCRETE. PLEASE FOLLOW HILTI ANCHOR INSTALLATION GUIDE PROVIDED WITH EACH SET OF ANCHORS. CAPACITY IS BASED ON INSTALLATION OF ANCHORS IN UN-CRACKED AND JOINT FREE CONCRETE. PLEASE CHECK WITH PLANT FACILITIES ENGINEERS FOR CONCRETE CONFORMANCE. FOR AREAS WITH SEISMIC ZONE REQUIREMENTS OTHER ANALYSIS MAY BE REQUIRED Min. 3000 PSI Concrete

Column to Beam Fasteners 1.0 in. [25mm] Heavy Hex Nuts ATSM A563 Grade DH 0.125 in. [3mm] Nominal Hardened Washers ATSM F436 Type 1 1.0 in. [25mm] ATSM A490, Type 1 Heavy Hex Structural Bolts 150,000 (Min.) PSI 173,000 (Max.) PSI Tensile Strength Joint Tightening Procedure Turn-of-the-nut pretensioning method: Snug tighten all fasteners to bring assembly into firm contact. Match mark the nut and bolt end with a single straight line. Using an appropriate alternating tightening pattern, apply a 1/2 turn to all fasteners.

Hangers, Safety Cables & Mid Rail Shocks Sway Cables with Turnbuckles Safety Cable MRHS42181 7-11 Flange Extended Stack I-Beam Hanger End Caps with Shocks on Runway 1.5 in. [38mm] 0.25 in. [6mm] Note: Hangers have 1.5 in. [38mm] of adjustment in 0.25 in. [6mm] increments.

Two Post Cantilevered Rail System Capacity Chart 1 ft. - 9 in. [533mm] Max. Distance, Typ. B Runway Centers 1 ft. [305mm] Runway Overhang A Column Centers 1 ft. [305mm] Beam Overhang "B" DIM RATED CAPACITIES (LBS.) Rated Capacities are based upon L/450 Deflection Criteria 20FT 330 320 315 305 295 290 280 270 265 255 245 240 230 220 215 205 19FT 480 470 460 455 445 435 430 420 410 405 395 385 380 370 360 355 18FT 650 640 635 625 615 610 600 590 585 575 565 560 550 540 535 525 17FT 740 725 710 695 680 665 650 635 620 605 590 570 555 540 525 510 16FT 975 960 945 930 915 900 885 870 855 840 825 810 795 780 765 750 15FT 1255 1240 1225 1210 1195 1180 1164 1150 1135 1120 1105 1090 1075 1060 1045 1030 14FT 1590 1575 1560 1545 1530 1515 1500 1485 1470 1455 1440 1425 1410 1395 1380 1365 13FT 2000 1985 1970 1955 1940 1925 1910 1895 1880 1865 1850 1835 1820 1805 1790 1775 12FT 2510 2490 2475 2460 2445 2430 2415 2400 2385 2370 2355 2340 2325 2310 2295 2280 11FT 3145 3130 3115 3100 3080 3065 3050 3035 3020 3005 2990 2975 2960 2945 2930 2915 10FT 3305 3290 3275 3260 3245 3230 3215 3200 3185 3170 3155 3140 3125 3105 3090 3075 10FT 11FT 12FT 13FT 14FT 15FT 16FT 17FT 18FT 19FT 20FT 21FT 22FT 23FT 24FT 25FT "A" DIMENSION NOTE: CAPACITIES INCLUDE ALL SUSPENDED BRIDGE LOADS PLUS HOIST WEIGHT. With 6 Backer With 8 Backer

Increase Cantilevered Rail System Weight Capacities Additional columns can be added to the two post system to achieve greater load capacities and minimize deflection. * Note: Additional bridge rails can be added also to multiple bay systems to support multiple operations. * *

Cantilevered Rail System Extended Runways Runways over 27 ft. [8230mm] long will require a rail splice kit. Rail Splice Kit 1 ft. [305mm] 25 ft. [7620mm] Runway

Maximum Two Post Dual Cantilever Rail System

Maximum Offset Three Post Cantilever Rail System An offset column can be added to the two post system to achieve greater load capacities and minimize deflection. Note: The added beam connections may vary from what is shown.