Applying For New or Revised Electric Service. ComEd is happy to assist you in initiating new or revised electric service to your location.

Similar documents
Applying For New or Revised Electric Service

ComEd Customer Requirements for Proper Installation of Metering Equipment Residential and Commercial Customers

OPERATING PROCEDURE NO. 310

Large Basic Service. This Section applies to members requiring new. Introduction. Service Types

New Construction Handbook

METERING INSTALLATION

Basic Service. This Section provides information regarding a. Introduction

REQUEST FOR ELECTRIC SERVICE Residential

SERVICE ENTRANCES. OPPD S Electrical Service Designer (ESD) shall designate the Point Of Entrance.

Welcome to Douglas County PUD

Welcome to Douglas County PUD

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

MEMPHIS LIGHT, GAS AND WATER DIVISION Application for Utility Services for Apartment Complexes

Central Lincoln PUD Commercial Service Guidelines & Standards

PRIMARY LINE EXTENSION

Primary Contact: Owner Customer Electrician Builder

Indianapolis Power & Light Company

RESIDENTIAL QUICK REFERENCE

Specifications for Residential Overhead Electric Service Installation

A12 Single Family Residential Back-up Generator. Address: Date Stamp. Application Requirements:

Central Lincoln PUD Single-Family Residential Guidelines & Standards April 21, 2017

UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 100 kw)

Revisions for the 2015 Edition of the "Specifications and Requirements for Electric Installations (Bluebook)"

Indianapolis Power & Light Company

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

ELECTRIC METERING GENERAL

Specifications for Residential Overhead Electric Service Installation

Multi-Family Load Requirements Form

Post Office Box 500 Carson, WA Phone (509) Fax (509) Toll Free (800)

New Construction Handbook

Please check with your local inspection authority for any additional requirements before installation.

Tucson Electric Power Company Rules and Regulations

MEMPHIS LIGHT, GAS AND WATER DIVISION Application for Utility Services for Apartment Complexes in the Network Area

Electric Service Requirement Handbook

pepco Contents Section 1 General Information 2 1.A Introduction 3 1.B Overview 3 1.C Pricing, Billing, and Payment Policies 6

Electric Service Standards

Residential Engineering P.O. Box 430 Memphis, TN (Deliveries at 5791 Summer Trees Memphis, TN 38134) (901) / (901) Fax

UNDERGROUND SERVICES - GENERAL SERVICE AND MULTI-UNIT RESIDENTIAL

OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE. See Chapter 3, Section 3.01 for more information about point of entrance (POE).

GPI Conditions of Service - Revision History The following is a summary of key changes made to the document.

ELECTRICAL SERVICE UPGRADE RESIDENTIAL AND COMMERCIAL QUICK INFORMATION REFERENCE

APPLICANT: Please read application and fill out Sections 1, 3 and 5. O&R may require documentation to verify any information given.

CITY OF LODI ELECTRIC UTILITY DEPARTMENT RULE AND REGULATION NO. 16 SERVICE CONNECTIONS AND FACILITIES ON CUSTOMER'S PREMISES

An altered service that is moved, upgraded (ex., 200 to 400 amp) or changed to meet today's standards for electric service.

Request for Electric and Gas Service Form

4. GENERAL REQUIREMENTS

4. GENERAL REQUIREMENTS

Call the Experts at REA Energy Services for all of Your Electrical and HVAC Needs.

Nashville Electric Service Electric Service Policies

Effective June, Eaton-Durham Model # UTRS223ACH. Siemens, Model # SUAS877-PG. (or Landis & Gyr # UAS877-PG) Milbank. Model # U1980-O.

RULE NO. 16 SERVICE CONNECTIONS, METERS AND CUSTOMER S FACILITIES

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

CUSTOMER SERVICE POLICIES

Electric Service Requirements Service Assembly Guide. Homer Electric Association, Inc Lake St. Homer, AK

UNITED COOPERATIVE SERVICES. SPECIFICATIONS FOR SELF-CONTAINED METER INSTALLATIONS August 2014

Electric Service Handbook

NY State Unified Solar Permit

a) Line and load compartments must be separated by a stable barrier.

GRAND RIVER DAM AUTHORITY TERMS AND CONDITIONS OF SERVICE FOR INDUSTRIAL OR COMMERCIAL ELECTRIC CUSTOMERS

Commercial Electric Policy

Electric Service Standards

METERING GUIDE PART 1 METERING GENERAL

Metering Requirements 750 Volts or Less

SECTION AUTOMATIC TRANSFER SWITCH

MEMPHIS LIGHT, GAS, AND WATER DIVISION Application for Utility Services for Residential Ranchette Developments (Lots of four acres or more)

1. Contractor shall obtain a valid electrical permit from the Town of Perinton.

[Type text] Heber Light & Power. Developers & Excavators. Electrical Service Requirements Manual

Residential Electrical Upgrade Permit Revised: 11/15/17

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

BLUEBOOK LITE. for Electrical Service. Edition

Commercial Solar Photovoltaic System Permit

The Official Meter Manual of JCREMC. Created by the Engineering Dept.

CONSTRUCTION SPECIFICATION FOR INSTALLATION OF POWER SUPPLY EQUIPMENT

If a new residence s electrical service is not located within 200 feet of existing

Specifications for the Secondary Installation of Communication Equipment on MLGW Transmission Structures

Electric Service Requirements & Guidelines

NY State Unified Solar Permit

Electric Service Handbook

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

ADDENDUM NO 1. TO: All Prospective Bidders DATE: 8/17/17 PROJECT: New Residence Hall (WP B)

WIRING RULES AND REGULATIONS OF TOMBIGBEE ELECTRIC POWER ASSOCIATION

Specifications for Residential Underground Electric Service Installation

For the 2008 Code, the minimum clear distances were revised to reflect an accurate metric conversion (also known as a soft conversion).

Gainesville Technical Center 5399 Wellington Branch Drive Gainesville VA Phone (703)

Addendum No Variable Frequency Drives Section A, revise per following:

REVISION NO.: 8 EFFECTIVE: 03/26/18

CUSTOMER METERING REQUIREMENTS

CUSTOMER METERING REQUIREMENTS

Procedure: Station Power Portfolio Application

Metering Requirements 750 Volts or Less

City of Branson APPLICATION FOR CONSTRUCTION PERMIT

OVERHEAD SERVICE. Table of Contents - Section 400

Small Scale Solar Permit Application

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered.

Solar Photovoltaic System Permit

Indianapolis Power & Light Company

Metering Requirements 750 Volts or Less

SERVICE ENTRANCE SPECIFICATIONS FOR RESIDENTIAL AND COMMERCIAL

Transcription:

ComEd Applying For New or Revised Electric Service ear Customer: ComEd is happy to assist you in initiating new or revised electric service to your location. ComEd must be notified prior to any new construction, relocation or upgrade of electric facilities. Please complete, sign and return the attached service and meter application to your ComEd representative you may wish to have your electrical contractor assist you in completing it. Please call 1-866-NEW ELEC (1-866-639-3532) to have a ComEd representative assigned to your project. Please have the zip code of your project site ready. This new service application form is an important first step in initiating electric service. ComEd depends upon the information contained in it to schedule site visits, design your electric delivery service, prepare contracts, schedule construction work and set up your electric account. Additionally, ComEd may need to secure permits from local municipalities to perform required work, so be sure to accurately complete and promptly return your service application. Please also be aware that it is the customer's responsibility to coordinate work with other involved utilities. Again, you may wish to consult your electrical contractor for assistance in this area. After your electric service application is received, your ComEd representative will review it. You or your electrical contractor may be contacted for further information or clarification. In addition, site visits by ComEd personnel may be required. Upon the completion of all required information, ComEd will send you contracts and sketches, along with charges if applicable. You must review, sign and return these documents. Again, the prompt return of these signed documents authorizing ComEd to begin new service installation work is very, very important. Upon receipt of these signed contracts and sketches, ComEd will finalize a date when crews can begin work on your project. Typically, we will be able to schedule the appropriate resources to begin your project a minimum of six weeks from the time we receive your signed sketches. Please note, that if ComEd crews are required to work outside of normal weekday working hours, overtime labor charges will apply. Lastly, please keep in mind the following important information regarding your new electric service: Some municipalities may require separate Fire Pump and Emergency services. Please remember to include these services on your new service application. You may be required to provide easements and space on your property, or inside your building for ComEd equipment. Like any other business, ComEd is obligated to obtain all necessary permits before beginning work. Promptly returning accurate and complete documents can help expedite this process. Subtractive Metering is not offered for new construction. New Construction is defined as building from the ground up. Subtractive Metering is grandfathered in with existing Subtractive Metering customers or on refurbished buildings with no other option except for Subtractive Metering. Please be aware that all customers now have a choice of electric suppliers, electric rates, metering option, etc. For more information, visit our Web site at www.exeloncorp.com or call our Business Solutions Center at 1-877-4-ComEd-1 (1-877-426-6331). We look forward to working with you. 1

ComEd Work Scheduling Information ear Customer: ComEd would like to inform you about its work scheduling process for all "new business" and construction-related activities. This process helps ComEd efficiently allocate its resources and maintain scheduling control and flexibility. A key element of this process is uninhibited, continuous communication between the customer and the ComEd engineer assigned to the project. To help ensure the timely completion of new projects, ComEd has identified the following sequence of events -- each one of which must take place: 1. New Service Application: wherein customer completes, signs and submits new service application and related documentation. 2. New Service Application Review: wherein ComEd reviews completed new service application and, based on submitted information, sends customer all necessary contracts and sketches, along with an itemized list of charges (if applicable) to begin electric service at the customer's location. 3. New Service Authorization: wherein the customer reviews, signs and returns contracts, sketches and cost estimates to ComEd authorizing work to begin. 4. Service ate etermination: wherein an "in service" date is negotiated between the customer and ComEd; a day that in turn generates a start work date, which commits ComEd to begin working on the project. 5. Service ate Confirmation: wherein four weeks prior to the "start work date," the ComEd project engineer will contact the customer to check on the project's progress and validate the proposed "start work" and "in service" dates. If the customer's project is not progressing as planned and the "in service" date needs to be rescheduled, the "start work" date will be adjusted accordingly. All work rescheduling will be subject to ComEd's workload and resource availability. If the customer's project is progressing as expected and the "in service" date is still valid, the "start work" date will be "locked in" to ComEd's construction schedule and resources will be allotted to the customer's project. 6. Final Site Inspection: wherein two weeks prior to the "start work" date, all conduits and pads that are to be provided by the customer must be ready for inspection and approval by ComEd personnel to allow ample time for modification or correction, if necessary. If conduits and pads are not ready for inspection, ComEd may reschedule the planned "start work" and "in service" dates. Please note, unanticipated events such as severe weather or other emergencies may delay the start of planned "work start" or "in service" dates. ComEd makes every attempt to notify its customers as soon as it becomes aware of these situations. 2

CornEd Service and Meter Application Switch and Load Information Sheet Project Name Site Address Electrical Permit # Switch Name and Location Service Voltage (check one): 120/240V 1-phase, 3-wire 277/480V 3-phase, 4-wire 120/240V 3-phase, 4-wire 480V 3-phase 3-wire (B-phase Grounded) 120/208V 3-phase, 4-wire 480V 3-phase 3-wire (Ungrounded requires ground detection equip.) Other: 4kV 12kV 34kV 3-phase, 3-wire 4kV 12kV 3-phase, 4-wire Other Items (check all that apply): New Construction Building Addition Sq. Ft. Sq. Ft. U nderground Service Overhead Service Relocating Existing Service Entrance Commercial No. of units: Sq. Ft: Hi-Rise/ Vault Service R esidential No. of units: Sq. Ft: Master/Subtractive Metering (Not allowed for new construction) ate of Ground Breaking (est.): ate to Final Grade (est.): ate to Energize: Hours of Operation Per ay: 8 12 16 24 Switch Size (amps): (If switchgear is 1,200 Amps or larger, customer must submit drawings for ComEd approval) Switch Rating (percentage): Secondary Conductors: Sets of /C CU or OJ AL (Number) (No. of conductors) (Type) Total Connected Load Information: ( KW or HP ) escription: Connected Load:* 1 -phase 3 -phase Lighting: VAC: Receptacle: Process Heat: Water Heat: Space Heat: Motors**: Welders***: TOTAL LOA: *Load used to size the service disconnect switch based on applicable Electrical Code **Motor Load etail included above: escription Quantity Size (HP) Efficiency Rating Phase/ Voltage Nema Code Starts Per Hour Starts Per ay Starting Amps Use ***Welder etail included above: escription Quantity Size (kva) Type Max. Inst. emand P.F. at Peak Welds Per Minute Cycles Per Weld Hours Per ay Use 3

CotnEd Service and Meter Application Project Information Sheet Project Name: Site Total Number of Service Entrance Locations (meters/switches) Requested: Legal Name of Entity (Electric Consumer): Corporation Partnership Sole Proprietor Other: Tax I..: Existing Account Number: Principle(s) to Sign Contracts For Service, Easements, Etc.: Property Owner: Building Owner: Building Manager: Phone: Phone: Phone: Mailing Address for Contracts: Company: Phone: Fax: Mailing Address for Electric Bills: Company: Phone: Fax: Project Contacts: Consulting Engineer: E-mail: Firm Name: Phone: Fax: Electrical Contractor: Consulting Engineer: E-mail: Firm Name: Phone: Fax: Other: Consulting Engineer: E-mail: Firm Name: Phone: Fax: The Following ocuments May Be Required: 1. Plat of Survey with legal description of property (for easement, if required) 2. Site Plan showing building relative to property lines mark service entrance location(s) 3. Civil drawings (showing water, sewer, gas, phone, electric, pavement, grading, etc.) 4. Complete electrical drawings and/or load detail sheets Information Provided By: Print Name: Signature: ate: 4

ComEd~ Metering Checklist ear Customer: To ensure that your location's electric meter equipment can be installed in a correct and timely manner, please have your electrician complete the attached Meter Checklist and return it to your ComEd representative. For additional metering information, visit our Web site at https://www.comed.com/newbusiness and select Supplemental ocuments from the drop down. Please be aware that ComEd s System Meter epartment must approve the installation of main electrical panels that are rated greater or equal to 1,200 amps & any service that is greater than 600 volts. To obtain approval: (1) a pdf of the one-line diagram for the meter current transformer cabinet and disconnect switch sequence can be emailed to SWB.Approvals@ComEd.com or (2) four physical copies can be submitted to ComEd: System Meter epartment at 1919 Swift rive, Oak Brook, IL 60523. Please be sure to include the electrical panel's manufacturer and model number. These diagrams may be found in your project's electrical plans or in the manufacturer s specifications for the panel. Talk to your electrical contractor if you need assistance acquiring these documents, and be sure to allow ComEd ample time to receive and review these items. All plans must be approved before service can be livened. If you have any questions, please contact your ComEd representative. The following items MUST be COMPLETE before any meters can be set. (Check all that apply) 5

Metering Checklist General Requirements: If applicable a permit must be obtained prior to ComEd notification and/or approval. ComEd~ All fittings must have a CECHA stamp to receive ComEd approval. Fittings must be located in a ComEd approved location. All meter sockets must be clearly identified with unit number, fire pump, building meter, etc. on the fitting. All units must be clearly identified, using the final unit number, designation and/or address on the unit s breaker panel. All load wires must be landed and terminated between the meter socket and unit panels. All new and existing services must have required grounds. Access to meter related facilities must be through public walkways, halls and other public areas, and must not be through locked or private rooms, tenant spaces, lavatories, or other limited access areas. For a situation in which the meter related facilities are located on a balcony, access to such meter-related facilities must be made by stairs, and must not be by ladder. Clear platform space of at least three (3) feet with suitable protective railings must be provided in front of any meter-related facilities located on a balcony. For a situation in which meter related facilities are located in a narrow passageway or area, clear space of at least three (3) feet must be provided in front of any such meter-related facilities. Single-phase Metering: A fifth jaw is required at the nine o clock position of the socket for WYE (120/208v) services. If there is no bypass handle provided on the socket, jumping studs/horns are required on the line and load connectors of the meter fitting. Meter fitting(s) must be at proper height. Service attachment (Iplate) must be installed in proper location and must be within minimum and maximum height clearances. Trees on private property must be trimmed and/or removed as needed by the customer to allow service drop installation. Three-phase Self-contained Metering: All three-phase, 120/240V, four-wire self-contained meter installations (200 Amps. or less), the high phase must be attached on the right side of the fitting and clearly identified within the meter fitting and at the weatherhead. All phases and the neutral must be clearly identified. An integrated bypass lever is required for all three-phase, self-contained meter fittings. Three-phase Transformer Rated Metering: High phase must be in the center position in all current-transformer cabinet installations. Please make sure the switchgear size, estimated demand load and voltages have been provided to the Project Engineer. Also, an approved wiring harness must be provided in all current-transformer cabinet installations (per ComEd requirements) when the meter fitting is on the CT cabinet door. NOTE: When all applicable items are checked off, sign, date and return this form to your ComEd representative. If applicable, a city/village inspection is required in addition to the above ComEd requirements. I hereby certify that all requirements set forth above for metering installation are complete: Customer/Contractor Signature: ate: Building/Project Address: ate: CBS-SMA01-1002 6