SOLVING ADHESION AND DIE BUILDUP PROBLEMS IN EXTRUSION COATING

Similar documents
INVESTIGATING SEALING ISSUES IN FLEXIBLE PACKAGING PRODUCTS

Standard Test Method for Oxidative-Induction Time of Polyolefins by Differential Scanning Calorimetry 1

Differential Scanning Calorimetry DSC 200 F3

Thermal Analysis Methods for Composites

A chemical change indicates the onset of oxidation or degradation of the material. 2,3 There are

Role of on-line gauging systems in providing insights into the Web Coating process

i Series Thermal Analysis Systems

Processing Guide CONTENTS

Rheological Studies on Radiation Modified Polyethylene Resins. Song Cheng* and Ed Phillips

Impact of Tzero Technology on DSC Resolution

PHARMACEUTICAL TECHNOLOGY REPORT. Introduction. Methods

Critical Guidance Protocol for Clear PET Resin and Molded Articles

DSC - Differential Scanning Calorimetry. Investigation of the Thermal Properties of Polymers

Adhesion in Extrusion Coating & Laminating - the Importance of Machine Variables. Bruce Foster Mica Corporation

NEW DEVELOPMENTS IN BETA NUCLEATION OF POLYPROPYLENE AND LASER PRINTING OF MICROPOROUS FILMS

Melting point: 133 C. Algro Brits. ph:

Physical Aging and Fragility of Amorphous Polyethylene Terephthalate

SEMATECH Provisional Test Method for Evaluating Bulk Polymer Samples of UPW Distribution System Components (DSC and TGA Methods)

A Short Reviews of Thermal Techniques

HDPE Critical Guidance HDPE- CG- 01

THERMAL TRANSITIONS BY DIRECTLY EXPANDED EXTRUDED MAIZE GRITS. Abstract

A High Performance Primer for Extrusion Coating at Low Temperatures. Presented by Ginger Cushing Business Development Flexible Packaging Michelman

Plastics Differential scanning calorimetry (DSC) Part 2: Determination of glass transition temperature and glass transition step height

Crystallization kinetics of PHB and its blends 3.1 Introduction

Standard Test Method for Transition Temperatures of Polymers By Differential Scanning Calorimetry 1

NU-AGE FILMS WHITE PAPER

Impact of Tzero Technology on the Measurement of Weak Transitions

TA INSTRUMENTS DIFFERENTIAL SCANNING CALORIMETERS

MICRONIZED TALC: A COST-EFFECTIVE FUNCTIONAL FILLER FOR POLYOLEFINS

Product Description. Item Unit Imperm 105 MXD6 Density non-crystallized crystallized

Analytical Testing for Product Development Whitepaper Dan Clark Lab Manager Teel Plastics, Inc. August 30, 2017

High Melt Strength Polypropylene

ISO INTERNATIONAL STANDARD. Plastics Differential scanning calorimetry (DSC) Part 2: Determination of glass transition temperature

EVALCA Technical Information. Purge Compound ETC-103

Ancamine 2337S Curing Agent

Champions for Change Critical Issues Guidance for Innovations

Synthetic Petroleum-Based Polymers

Additive and Colour Preparations. for Extruded Polystyrene Foams

THE EFFECT OF BIAXIAL ORIENTATION PROCESSING CONDITIONS ON IMMISCIBLE POLYMER BLENDED SHEET

Montmorillonite as Flame Retardant for Flexible Poly (Vinyl Chloride)

Cost savings and quality improvements in plastics processing

Physical Aging and Fragility of Amorphous Sucrose by DSC

APPLICATIONS OF XRD,DSC,DTA. Presented by Dr. A. Suneetha Dept. of Pharm. Analysis Hindu College of Pharmacy

INTRODUCTION. Table 1. Typical applications for LDPE and Ateva EVA copolymers. Category Typical Applications Advantages

Examination of the Performance of a High Speed Single Screw Extruder for Several Different Extrusion Applications

Binder Optimization for the Production of Tungsten Feedstocks for PIM

Primerless Heat Seal Coatings for Film Substrates

THE EFFECT OF CRUCIBLE TYPE ON DIFFERENTIAL SCANNING CALORIMETRY (DSC) MEASUREMENTS

INFLUENCE OF TALC INCORPORATION ON THE THERMAL PROPERTIES OF POLYSTYRENE COMPOSITES

High Heating Rate DSC

Preface. Thank you. Introduction. Chapter 1 Extrusion Equipment. Extrusion Coating Manual, 5 th Edition -Table of Contents

DRUG- POLYMER COMPATIBILITY STUDIES

Critical Guidance Protocol for Clear PET Articles with Labels and Closures


Thermal Stability of Sodium Alendronate in a Mixture with Cross-linked Acrylic Acid Polimers and Chitosan

Plastics Differential scanning calorimetry (DSC) Part 6:

on a Perkin-Elmer (Dublin, Ireland) Spectrum 100 FT-IR spectrometer fitted with a Universal ATR Sampling Accessory.

AGRU Specialized Geomembranes COEXTRUDED BLACK/WHITE AND CONDUCTIVE GEOMEMBRANE LINERS

Benchmark Test for Clear PET Resin and Molded Articles

APPLICATIONS OF HIGH SENSITIVITY DSC

Rory A. Wolf, Enercon Industries Corporation Amelia Sparavigna, Dipartimento di Fisica, Politecnico di Torino

ISO INTERNATIONAL STANDARD

Online Training Courses

Thermal Analysis Investigation of a Poly(Lactic Acid) Biodegradable Plastic

Bull. Mater. Sci., Vol. 33, No. 3, June 2010, pp Indian Academy of Sciences.

PP Benchmark Test HDPE- B- 01

Initial research efforts focused upon blending PEOx with sufficient plasticizer and talc a Brabender an effort to decrease viscosity

BindEX speciality polymer for multilayer films (E-189) PRODUCT APPLICATION NOTES

(12) Patent Application Publication (10) Pub. No.: US 2005/ A1

Marlex Polyethylene Resins

Producing Foam Sheet using Extrusion

EXPERIMENTAL APPLICATIONS OF DIFFERENTIAL SCANNING CALORIMETRY TO TEST AND CHARACTERIZE POLYMERS AT THE UNIVERSITY OF WASHINGTON BOTHELL

SECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors.

V 1 m/min. V max (press) V 1 max. Temperature C. Arch. Metall. Mater., Vol. 61 (2016), No 1, p Introduction

FURTHER DETAIL FROM DSC THERMOGRAMS

Comparison of Atmospheric Plasma and Corona Treatments in Promoting Seal Strength

Product Information Plastics Dow Corning MB Masterbatch

Instructions for using the PerkinElmer DSC-8500

Study of glass transition of metallic glasses by temperature-modulated differential scanning calorimetry (MDSC)

Report On Adsorption/Desorption Studies of CO on PEM Electrodes Using Cyclic Voltammetry. Sethuraman, Vijay Anand

Polymers Performance Overview. Bruce Duncan. Wednesday 18 th April 2007

Dynamar TM Polymer Processing Additives (PPA s)

Preface... iii Contents...vii Contributors...xv. 1 Introduction to Hot-Melt Extrusion, Continuous Manufacturing: Scale-up via Hot-Melt Extrusion...

STEER BEST PRACTISES

MECHANICAL PROPERTIES AND CHARACTERIZATION OF INJECTION MOLDED MICROCELLULAR POLYPROPYLENE (PP)/CARBON FIBER COMPOSITE

Collected Applications Thermal Analysis ELASTOMERS. Volume C

Atmosphere Effect on Soldering of Flip Chip Assemblies. C. C. Dong Air Products and Chemicals, Inc. U.S.A.

ISO INTERNATIONAL STANDARD

CHARACTERISTICS OF THE PYROLYSIS AND GASIFICATION OFLOW-DENSITY POLYETHYLENE (LDPE)

DOW CORNING MB Masterbatch

EXTRUSION OF ELASTOMER FILM, EFFECTS OF ELASTOMER DESIGN ON CHILL ROLL STICKING

Thermal Residue Fingerprinting: A Revolutionary Approach to Develop a Selective Cleaning Solution

Buffer Compatibility with Nano DSC

Paper and Paperboard Converting

Norman Aubee & Brad Kramer NOVA Chemicals Corporation

Methodology for DSC calibration in high heating rates

Transition Temperature Microscopy Nano-scale Thermal Analysis Technique

Product and Properties Guide Alcryn fi MPR

PB 250, PB 400 / SD 560x Resilient & ambient curing epoxy foam

A COMPARISON OF EVAL EVOH RESINS AND PA MXD6 RESINS

Transcription:

SOLVING ADHESION AND DIE BUILDUP PROBLEMS IN EXTRUSION COATING Bruce Foster Mica Corporation ABSTRACT Poor adhesion and die buildup are common problems in the extrusion coating industry. In the case of polymer systems requiring stabilization packages (e.g.: polypropylenes, linear low density polyethylenes, and metallocene grades), such problems can sometimes be caused by a mismatch between the resin supplier s stabilization package and the customers needs. This paper, based on real life examples, shows how a simple lab test oxidative induction behavior can be used to optimize additive packages to solve such problems. BACKGROUND In all extrusion coating processes, polymers are oxidized to some extent as they go from pellet to coating. In most cases, sufficient oxidation of the melt curtain in the air gap is necessary to effect good adhesion. On the other hand, excessive oxidation during extrusion can result in a buildup of oxidized polymer in the extruder, on the screen pack, and at the die lips, resulting in streaks or die lines. Thus, an analytical tool to correlate the oxidative stability of a resin with end use performance can be an important tool in the development of new or improved resins for extrusion coating. In this paper, we use several product development success stories to illustrate the merits of such a tooloxidative induction testing. EXPERIMENTAL For this work, a Perkin Elmer DSC 7 differential scanning calorimeter was used, although any similar instrument, when equipped with a gas switching accessory, should be suitable. Also needed are supplies of pure nitrogen and oxygen and a means of regulating and measuring the gas flow rates. The instrument used in this study is shown schematically in Figure 1. The test method used is in accordance with ASTM D3895, and is summarized as follows: 1. A 10 mg. sample is placed in an open test pan. 2. Heat to 200 C (30 C/minute heat rate) with nitrogen purging. 3. Hold at 200 C (i.e. isotherm) for 5 minutes. 4. Switch to oxygen purge at a gas flow rate of 10 cc/min. The effect then, is to induce oxidation of the exposed polymer surface, which occurs once its limit of resistance to oxidation is reached. Because the oxidation reaction is exothermic, it is easily detected on the test thermogram, as illustrated in Figure 2. The time between switching to oxygen and the extrapolated onset of the exotherm is defined as the polymer s oxidative induction time. (See figure 2) The effect of temperature on the induction times is rather dramatic, as illustrated in Figure 3. For our purposes in this work, 200 C was determined to give a good balance between induction times long enough to get a good baseline, yet short enough to keep the test time reasonable. EXAMPLES The following examples demonstrate use of this method to solve stability related problems. EXAMPLE 1: Problem: Poor adhesion

In a commercial extrusion coating operation, Formula A was observed to have poor adhesion to a paper substrate, whereas Formula B exhibited good adhesion. Testing revealed A had a longer oxidative induction time, as illustrated in figure 4. The stabilization package in A was changed to reduce this time from 13 minutes to ~2 minutes, as illustrated in Figure 5. This revised formulation, A gave excellent adhesion. EXAMPLE 2: Problem: Die buildup A second commercial extrusion coating operation, very similar to that discussed above, was using Product C to successfully coat paper in an application requiring a very uniform coating profile. When Product D (a more desirable polymer for economic reasons) was substituted, the process was plagued by die buildup, resulting in die streaks on the coating. Figure 6 shows that Product D had a shorter oxidation time than C, suggesting that degradation in the extruder was causing the problem. When the stabilization package in D was adjusted to improve the oxidation resistance (Formulation D ), as illustrated in figure 7, the die buildup problem was resolved. Figure 7 also illustrates the importance of comparing not only the extrapolated onset, but the slope of the oxidation exotherm. Although the visible onset of oxidation for D is earlier than that of C, the lesser slope for D suggests it oxidizes at a slower rate than C, and the result is a product that adequately survives the extrusion process. CONCLUSION These examples illustrate the utility of oxidative induction testing for solving polymer stability problems, such as adhesion and die buildup. They also demonstrate the reality that different extrusion operations, although they may be performing similar functions, can have significantly different stability needs. Careful use of this method can successfully pinpoint the additive requirements for meeting these needs.