SW 846 METHOD 5035 FIELD SAMPLING GUIDE

Similar documents
OPERATIONAL MEMO GEN-14 Revision 3. November, Volatile Organic Compound (VOC) Sediment Sampling Method 5035 Field Sampling Procedure

Best Practices for Collecting Soil Samples for VOC Analysis

Best Practices for Collecting Soil Samples for VOC Analysis

STANDARD OPERATING PROCEDURE FOR SOIL, SEDIMENT, AND SOLID WASTE SAMPLING

Best Practices for Collecting Soil Samples for VOC Analysis. David Kaminski - QED Environmental Systems Inc. Dave Turriff - En Novative Technologies

EPA Method Proper Collection and Analysis of Soil Samples for Volatile Organics....Green Technology through Innovation

Best Practices for Collecting Soil Samples for VOC Analysis

Best Practices for Collecting Soil Samples for VOC Analysis. David Kaminski - QED Environmental Systems Inc. Dave Turriff - En Novative Technologies

SOIL SAMPLING FOR VOLATILE COMPOUNDS

NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION

Best/Worst Practices for Soil VOC Sampling Webinar VOLATILE ORGANIC COMPOUND ANALYSIS

Required Use of Method SW

FIELD PROCEDURE: TURBIDITY

Methods and Materials Manual Of Ion Chromatography Using DX-100 IC. Collecting Samples. LDPE bottle with cap (pre-rinsed with DI water)

Standard Test Section: SAMPLING Procedures Manual

Topical Report. By Susan S. Sorini John F. Schabron Joseph F. Rovani, Jr. September 2003

COPY. Region4 U.S. Environmental Protection Agency Science and Ecosystem Support Division Athens, Georgia

Soil Sampling and NAPLANAL

Preservation, Custody, and Shipment

Direct-Push Soil and Groundwater Sample Collection (Geoprobe ) (pg. 23) Calculation of Purge Volumes for Groundwater Sampling Wells (pg.

Required Use of Method Sw

Contamination Prevention and Decontamination

STANDARD OPERATING PROCEDURES SOP: 2040 PAGE: 1 of 10 REV: 0.0 DATE: 05/17/02

ATT-42/95 SAMPLING, Asphalt

Course Outline. in Soil/Sediment&WasteSediment&Waste by. Overview of VOCs Analysis Sample Collection VOCs Analysis

Surface Soil Sampling

Specific Heat. q = csm T (1)

Lab 6: Crystal Growing a competition

STANDARD OPERATING PROCEDURE FOR SPRING AND SEEP SAMPLING

SAMPLE PRESERVATION Liz Miller February 21, 2017

Silage DNA extraction procedure

CHAPTER 2 2:3 ADMINISTERING HEAT /COLD APPLICATIONS

Experiment: Measurements

Collecting a Surface Water Sample

SAFETY DATA SHEET PS Rev. 1

Centre d expertise en analyse environnementale du Québec

Liner Replacement Instructions:

Safety Data Sheet. according to Regulation (EC) No 1907/2006 ONTOP. SECTION 1: Identification of the substance/mixture and of the company/undertaking

AgraStrip RUR Strip Test

CARDINAL SURVEYS COMPANY. Ejector Loading Procedures

CH 112 Special Assignment #6 The Case of the Phony Fruit

Wipes for Disclosing the Presence of Lead

STANDARD OPERATING PROCEDURES SOP: 1502 PAGE: 1 of 11 REV: 0.0 DATE: 10/24/94

Last Revised: 1/2018 Prior Version: 12/2014 SOP NUMBER: SC-402 Page 1 of 9

MASS PER CUBIC FOOT (METER), YIELD, AND AIR CONTENT (GRAVIMETRIC) OF FRESHLY MIXED CONCRETE (Kansas Test Method KT-20)

Peanut ELISA Kit. For the quantitative determination of peanut protein in food. Catalog #M Assays

Woods Hole Oceanographic Institution. Woods Hole, Massachusetts U.S.A.

Bulk Density Protocol

AgraQuant Aflatoxin B1 Assay (2-50ppb) Order No.: COKAQ8000/COKAQ8048

Cadmium Testing and On Site Calibration for Water Testing Detection Range: ppm

Zinc Testing and On Site Calibration for Water Testing Detection Range: 1 15ppm

PROGRAM FOR THE MANAGEMENT AND DISPOSAL OF RADIOACTIVE WASTE

SAFETY DATA SHEET PS Rev. 0

Orono Spectral Solutions, Inc.

Safety Data Sheet in compliance with Indian Manufacture, Storage and Import of Hazardous Chemicals Rules 1989, Rule 17, Schedule 9

Radioactive Waste Radiation Safety Orientation Open Source Booklet 7 (June 1, 2018)

Laboratory (LAB) prepares sample kits prior to Epidemiologist Investigator (EPI) arrival.

Human CRP Precoated ELISA kit

SUPER FRESHNESS METER KV-202. Instruction Manual

Identify and Correct Impact of Water Health Challenges Associated with Flooding. Susan Watkins and Mike Daniels

Biotechnology Science for the New Millennium by Ellyn Daugherty

Bovine IgG ELISA Kit

Uranium Testing and Site Calibration for Water Testing Detection Range: 2 60ppb

VAREC 3600B/3650B SERIES PRESSURE OR VACUUM RELIEF VALVES INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

Instructions for Use: Duodenoscope Sampling Kit

UCI KCCAMS Facility. Leaching/hydrolysis protocol (carbonate samples) December 26, 2011

Volatile Organic Compounds in Solids PBM

Agilent Multiple Affinity Removal Spin Cartridges for the Depletion of High-Abundant Proteins from Human Proteomic Samples.

DNA FINGERPRINTING 3/2003 TEACHER PREPARATION AND INSTRUCTION GUIDE FOR USE WITH CAROLINA BLU STAIN

Saliva DNA Collection, Preservation and Isolation Kit 50 Individual Devices

SOP: PP003.2 Modified: 6/10/2010 Large-scale growth of Mycobacterium tuberculosis

Appendix A. Do not rinse or empty bottles. Several bottles contain a preservative that must remain in the bottle.

HAZARDOUS WASTE MANUAL Procedure Cover Sheet

WESTPAC Training Workshop Research and Monitoring of the Ecological Impacts of Ocean Acidification on Coral Reef Ecosystems

How To... Take Tissue Samples for Histopathology

Introduction. Think of this Guide as a collection of cheat sheets - a quick reference of FAQs and issues that we get calls on all the time:

Contact Information: Laboratory Supervisor: Denise Kind Laboratory Manager: Mat Ashby

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

InfraCal 2 Analyzer. User s Guide. Model ATR-SP. WilksIR.com

Material Safety Data Sheet

IACUC Standard Operating Procedure SOP : Isolation of Hazardous Chemicals/Agents in Use in Rodents

SAFETY DATA SHEET PS Rev. 2

ABI Prism 310 Cycle Sequencing Protocol Economy Version

Residual Solvents in medical cannabis analysis using the SRI 8610C FID GC June 2014

Pathology and Correlative Science Instructions for NRG Oncology Trials: San Francisco Bank Kits Version

Safety Services Guidance. Guidance on the safe use and disposal of ethidium bromide

STANDARD OPERATING PROCEDURES

MATERIAL SAFETY DATA SHEET SECTION 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION SECTION 2. COMPOSITION, INFORMATION ON INGREDIENTS

Manual. AGRETO Hydraulic Scale AGRETO electronics GmbH

With Discovery Incubator.

Pure Epoxy Adhesive For Premium Engineering Applications. Product Advantages. Meets the highest anchoring standards

CHEMICAL/BACTERIA KIT - FLUIDS

Use and Disposal of Acidic Piranha Solutions

ecosphere water purifier 3in1 USER MANUAL

SAFETY DATA SHEET 1. IDENTIFICATION OF THE SUBSTANCE/MATERIAL AND THE SUPPLIER 2. HAZARD IDENTIFICATION. Date of Issue: 9/5/18. Product Number: DTC-2

Downloaded from and current as of 02/01/2008

Laboratory Biosafety Plan

Tracer TM Total Chlorine PockeTester Code 1740

Determination of Aluminum by Fluorometry

Recommended Procedure for Sampling Gastrointestinal Flexible Endoscopes

Transcription:

EN CORE SAMPLER COLLECTION FOR LOW LEVEL ANALYSES (>1 UG/KG) When sampling for low level analyses, a high level sample also needs to be collected. EN CORE SAMPLING Two5g samplers. One 25g sampler or one 5g sampler for screening and/or high level analysis. (The sampler size used will be dependent on who is doing the sampling and who is doing the laboratory analysis). One T-handle. 1. Remove sampler and cap from package and attach T-handle to sampler body. 2. Quickly push the sampler into a freshly exposed surface of soil until the sampler is full. 3. Use paper toweling to quickly wipe the sampler head so that the cap can be tightly attached. 4. Push cap on with a twisting motion to attach cap. 5. Fill out label and attach to sampler. 6. Repeat procedure for the other two samplers. 7. Collect dry weight sample-fill container. 8. Store samplers at 4 degrees Celsius. 9. Ship sample containers with plenty of ice to the laboratory within 40 hours of collection.

EN CORE SAMPLER COLLECTION FOR HIGH LEVEL ANALYSES ( > 200 UG/KG) EN CORE SAMPLING One 25g sampler or one 5g sampler (The sampler size used will be dependent on who is doing the sampling and who is doing the laboratory analysis). One T-handle. 1. Remove sampler and cap from package and attach T-handle to sampler body. 2. Quickly push the sampler into a freshly exposed surface of soil until the sampler is full. 3. Use paper toweling to quickly wipe the sampler head so that the cap can be tightly attached. 4. Push cap on with a twisting motion to attach cap. 5. Fill out label and attach to sampler. 6. Collect dry weight sample-fill container. 7. Store samplers at 4 degrees Celsius. 8. Ship sample containers with plenty of ice to the laboratory within 40 hours of collection.

ACID PRESERVATION SAMPLING FOR LOW LEVEL ANALYSES ( > 1 UG/KG) ACID PRESERVATION SAMPLING (CONT.) 1. Wear gloves during all handling of pre-weighed vials. 2. Quickly collect a 5g sample using a cut off plastic syringe or other coring device designed to deliver 5g of soil from a freshly exposed surface of soil. 3. Carefully wipe exterior of sample collection device with clean paper toweling. 4. Quickly transfer to the appropriate VOA vial, extruding with caution so that the solution does not splash out of the vial. 5. Add more acid if necessary (this is based on the buffering testing discussed in the previous section). 6. Use the paper toweling and quickly remove any soil off of the vial threads. 7. Cap vial and weigh the jar to the nearest 0.01 g (IAETL suggests nearest 0.1g). 8. Record exact weight on sample label. 9. Repeat sampling procedure for the duplicate VOA vial. 10. Weigh the vial with methanol preservative in it to 0.01g. If the weight of the vial with methanol varies by more than 0.01 g from the original weight recorded on the vial-discard the vial. If the weight is within tolerance it can be used for soil preservation below. (IAETL suggests weighing to the nearest 0.1g) 11. Tare the empty jar or the jar that contains the methanol preservative. 12. Quickly collect a 25g or 5g sample using a cut off plastic syringe or other coring device designed to deliver 25g or 5g of soil from a freshly exposed surface of soil. The 25g or 5g size is dependent on who is doing the sampling and who is doing the laboratory analysis. 13. Carefully wipe the exterior of the collection device with clean paper toweling. 14. Quickly transfer the soil to an empty jar or a jar that contains methanol. If extruding into a jar that contains methanol be careful not to splash the methanol outside of the vial. Again, the type of jar received is dependent on who is doing the laboratory analysis. 15. If the jar used to collect the soil plug was empty before the soil was added, immediately preserve with the methanol provided using only one vial of methanol preservative per sample jar. 16. Use the paper toweling and remove any soil off of the vial threads and cap the jar. 17. Weigh the jar with the soil in it to 0.01g and record the weight on the sample label. (IAETL suggests weighing to the nearest 0.1g). 18. Collect dry weight sample-fill container. 19. Store samples at 4 degrees Celsius. 20. Ship sample containers with plenty of ice and per DOT regulations (CORROSIVE, FLAMMABLE LIQUID, POISON) to the laboratory.

METHANOL PRESERVATION SAMPLING FOR HIGH LEVEL ANALYSES ( > 200 UG/KG) METHANOL PRESERVATION SAMPLING One pre-weighed jar that contains methanol or a pre-weighed empty jar accompanied with a pre-weighed vial that contains methanol. Weighing balance that accurately weighs to 0.01g (field balances may not reliably weigh to 0.01g). IAETL suggests 0.1g. Set of balance weights used in daily balance calibration. Gloves for working with pre-weighed sample vials. 1. Wear gloves during all handling of pre-weighed vials. 2. Weigh the vial with methanol preservative in it to 0.01g. If the weight of the vial with methanol varies by more than 0.01 g from the original weight recorded on the vial-discard the vial. If the weight is within tolerance it can be used for soil preservation/collection below (IAETL suggests weighing to the nearest 0.1g). 3. Tare the empty jar or the jar that contains the methanol preservative. 4. Quickly collect a 25g or 5g sample using a cut off plastic syringe or other coring device designed to deliver 25g or 5g of soil from a freshly exposed surface of soil. The 25g or 5g size used is dependent on who is doing the sampling and who is doing the laboratory analysis. 5. Carefully wipe the exterior of the collection device with clean paper toweling. 6. Quickly transfer the soil to an empty jar or a jar that contains methanol. If extruding into a jar that contains methanol be careful not to splash the methanol outside of the vial. Again, the type of jar used is dependent on who is doing the laboratory analysis. 7. If the jar used to collect the soil plug was empty before the soil was added, immediately preserve with the methanol provided-using only one vial of methanol preservative per sample jar. 8. Using the paper toweling-remove any soil off of the vial threads and cap the jar. 9. Weigh the jar with the soil in it to 0.01g and record the weight on the sample label. (IAETL suggest weighing to the nearest 0.1g). 10. Collect dry weight sample-fill container. 11. Store samples at 4 degrees Celsius 12. Ship sample containers with plenty of ice and per DOT regulations (CORROSIVE, FLAMMABLE LIQUID, POISON) to the laboratory.