F.S.P.M.A. PAINT SPECIFICATION DIVISION 9 FINISHES SECTION INTERIOR MP-47.2 MOLD AND MILDEW PROOF ACRYLIC PAINT

Similar documents
F.S.P.M.A. CUSTODIAL/FOOD SERVICE CHEMICAL SPECIFICATION FOR GENERAL EDUCATION FACILITIES USE

F.S.P.M.A. CUSTODIAL/FOOD SERVICE CHEMICAL SPECIFICATION FOR EDUCATIONAL FACILITIES USE

SECTION 1045 PAINT FOR STRUCTURAL STEEL

PAINTS AND ENAMELS. Package the paint in new containers marked with the following information:

DMS-4650, Hydraulic Cement Concrete Curing Materials and Evaporation Retardants

SPECIAL SPECIFICATION 7270 High Build Paint

MDC MicroTex Eggshell Micro-Textured Ceramic Coating for Walls

2018 TRAFFIC PAINT AND GLASS BEADS BID

2019 TRAFFIC PAINT AND GLASS BEADS BID

TECHNICAL DATA SHEET HYDROPOX #2 4:1 EPOXY (MPI #115)

DMS STRUCTURAL STEEL PAINTS PERFORMANCE

Acrylitex Interior Texture and Coating Submittal Documentation

Stamped Asphalt Generic Specification

Sample Specification

TECHNICAL DATA SHEET HYDROPOX #4 QD 1:1 EPOXY WATERWHITE CLEAR

SAMPLE SPECIFICATION

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

SPECIFIER SHALL REMOVE COMMENTS IN BOLD TEXT PRIOR TO SUBMITTING.

SAMPLE SPECIFICATION

DMS-8101, Structural Steel Paints - Performance

ZONE 7 WATER AGENCY CWS 5 TURNOUT REPLACEMENT PROJECT # ADDENDUM NO. 3 April 02, 2019

Ger-Eck, LLC SCRIBIL Dry Erase Clear Coat Section July 12, 2013 SECTION SCRIBIL Dry Erase Clear Coat

Note: Delete any section below not relevant to this project; add others as required.

NAVSEA REVIEWED ASTM F-718. Tenacious One Step Epoxy Flooring

80201R StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Sunhan M&T Funzi-out. Mold & Mildew Resistant Paint. Sunhan M&T Co., Ltd.

A. Section includes surface preparation and application of wood finishes[.]

Magna Wall. Elastomeric Coatings (Non-Textured) Product Overview, Instructions, & Data

BAYBLOCK HT/BAYBLOCK HT BASE

SECTION High Performance Coatings Field Applied Acrylic Urethanes (Solid Color, Pearl and Metallic Finishes)

SKIMM /DUROFLOAT A High Performance Filling Compound For Interior Walls DST301. SKIMM / DUROFLOAT Specifications

TT-S-300A April 25, 1977 SUPERSEDING Fed. Spec. TT-S-300 May 3, 1963 FEDERAL SPECIFICATION SHELLAC, CUT

COMMERCIAL ITEM DESCRIPTION ELECTROCOATING PRIMER

A. Section includes surface preparation and the application of high-performance coating systems on the following substrates:

MDC Ceramic Eggshell Ceramic Coating for Walls

Triarch One Energy Way. West Warwick, RI

TWO PACK AMINE CURED EPOXY RESIN PAINT PRIMER, INTERMEDIATE AND TOP COAT FOR ATMOSPHERIC ENVIRONMENT ORIGINAL EDITION MAR. 1996

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80657R StoColor Texture Fine Textured Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Aliphatic Acrylic-Polyester Polyurethane

Complementary Coatings Insl-x. Stix Bonding Primer Introduction

Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

1.2 SUMMERY A. Section Includes: 1. High-Performance Polyurethane Resinous flooring systems. 2. Decorative Polyurethane Resinous flooring systems.

80212R StoColor Lastic Acrylic-Based, Elastomeric Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

80648R StoCoat Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

ROCKGRIP UNIVERSAL ACRYLIC PVA

Technical Data Sheet

80648R StoColor Acryl Plus Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for Recoating Prepared, Previously Painted Surfaces

Refer to Substrates & Surface Preparation.

SECTION EPOXY MOSAIC COMPOSITION FLOORING Dex-O-Tex Cheminert Terracolor

ChemMasters. Installation Guidelines

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

DMS EPOXIES AND ADHESIVES

StreetBondSR Specification Help

two component high build amine adduct cured phenolic epoxy primer

DMS-6300, Waterproofing

Tennant Company October North Lilac Drive Minneapolis, Minnesota Guide Specification

White, a range of ready-mixed colours, and colours from the Dulux Colour System

POLYACRYLATE MODIFIED THINSET TERRAZZO 1

DMS-8111, Anti-Graffiti Coatings

80201 StoColor Acryl Flat Acrylic-Based, Vertical Above-Grade Exterior Wall Coating for New Concrete, Stucco, and Masonry Construction

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Cleaning and Protecting Concrete Surface Preparation, Application, and Inspection. NESMEA October 17, 2017 Kenneth A. Trimber KTA-Tator, Inc.

Associated Spec Consultants, Inc. February 27, 2014 SECTION ARCHITECTURAL COATINGS

Protective Industrial Polymers - USA Manufacturer s Specification February 11, 2015

Exterior pipes, Fences, screens, grills and gates, Metallic Structures, Structural elements (column, trusses, etc.)

STATE OF NORTH CAROLINA DRAFT G, May 11, 2009 DEPARTMENT OF ADMINISTRATION DIVISION OF PURCHASE AND CONTRACT F, February 6, 2007

POLYURETHANE COATINGS ON STEEL OR DUCTILE IRON PIPE

Section COATING RESTORATION

The City of Winnipeg NEWPCC Lab Renovation

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Property Test Method Typical Value

EPOXY TERRAZZO 1 REV. 8/02

Approved. Property Test/Standard Description STANDARD GRADE. semi gloss (35-70) Flash point ISO 3679 Method 1

GRIP-GARD PLUS BRUSH / ROLL ADDITIVE

Need help? Give us a call.

SECTION COMMON WORK RESULTS FOR CONCRETE SSPECIALTY COATINGS

NSP SPECIALTY PRODUCTS Technical Data Sheet. NSP 120 High Performance Epoxy Coating

SPECIAL SPECIFICATION 5478 Anti-Graffiti Coating

SPECIAL SPECIFICATION 5457 Anti-Graffiti Coatings

Aerowave Technical Data Sheet. Product Group. Epoxy topcoats. Characteristics

SECTION HIGH PERFORMANCE COATINGS Ramuc Type EP Epoxy Updated October 5, 2015

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

Grey, pourable liquid with slight gel Slight ammonia odor Specific Gravity: 1.34

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR WARRANTY ON CONCRETE SURFACE COATING

1/16 Single Broadcast Polymer Flooring System

1.04 REFERENCES STANDARDS.1 For reference standards tests & results refer to Manufactures Product Data Sheets

FLEXMAR 3-Coat High-Build Colored Quartz System

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1

SPECIAL SPECIFICATION 5764 Anti-Graffiti Coatings

GUIDE SPECIFICATION SECTION 07576

ARCHITECTURAL SPECIFICATION

Imagine a product which. waterproof your surface, saves. paint cost, protect the structure. from ageing and remain on the. surface forever...

RENOVATE BUILDING 18-C FTFA SECTION GYPSUM BOARD 05/11

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Polyurethane topcoats

JAXSAN AG-102 HIGH GLOSS PAINT/SEALANT

Product Guide Specification

This Section includes surface preparation and field application of anti-graffiti coating systems for the following vertical and horizontal surfaces:

Transcription:

I. SCOPE, USE AND CLASSIFICATION F.S.P.M.A. PAINT SPECIFICATION DIVISION 9 FINISHES SECTION 09920 INTERIOR FOR GENERAL EDUCATION FACILITIES USE MP-47.2 MOLD AND MILDEW PROOF ACRYLIC PAINT A. SCOPE: This specification covers white or colored water-based 100% acrylic modified antimicrobial, self-protective finishes intended to protect the paint film itself from the growth of mold, mildew and odor causing micro-organisms. B. USE: This product can be used internally on walls, ceilings, insulations and most other building materials (wood, brick, block, stucco, concrete, primed metals etc.). It can also be used as part of mold remediation or a preventative system in wall cavities (ie, frame lumber, studs, drywall backing etc). All labels shall be firmly secured to each container and should include adequate use instructions and an indication of compliance with ANSI standards. Labels shall meet all federal regulation requirements of the Occupational Safety and Health Administration (OSHA) Hazard Communication Standard in CFR 1910.1200 C. CLASSIFICATION: The paint covered by this specification shall be of one of the following three (3) types: TYPE I: Flat/Eggshell Finish TYPE II: Satin Finish TYPE III: Semi-Gloss Finish II. REQUIREMENTS A. MATERIALS: The paint shall be formulated from materials as specified herein. Materials not specified shall be selected by the supplier and shall be subject to all provisions of this specification. The paint shall be free from materials known to be toxic to personnel under normal conditions of use. 1. VEHICLE: The vehicle shall consist of a 100% acrylic emulsion resin or 100% acrylic modified resin. 2. RESTRICTED METALS: The coating shall comply with the latest requirements of the Federal, Florida State, City or Local Governments for maximum allowable restricted metals content. 3. VOLATILE ORGANIC COMPOUNDS (VOC'S) COMPLIANCE: The paint shall comply with the latest requirements of the Federal, Florida State, City or Local Governments for maximum allowable VOC content at the time of purchase. B. QUANTITATIVE REQUIREMENTS: The paint shall conform to quantitative requirements as specified in Table I. Page 1

TABLE I. QUANTITATIVE REQUIREMENTS Tolerance Requirements Characteristic Minimum Maximum 1. % Solids by weight 42 70 2. Weight per gallon (lb/gal) 10.0 12.0 3. Reflectance @ 400 ft 2 /gal (%) 84 98 4. Opacity contrast ratio @ 400 ft 2 /gal (%) 95 98 5. Drying time (hr) : a. to touch b. to hard c. to recoat 6. 60 o Gloss (%) a. Type I b. Type II 0.5 0.75 2.0 c. Type III 7. Consistency ( viscosity, KU) 80 110 8. Flash Point ( 0 F) > 200-9. Fineness of grind (Hegman units) 3-10. Scrubbability (cycles) 1000-11. Sag Resistance (mil) 7.0-12. Nonvolatile matter, % by volume of paint*. 39 - * In order to confirm compliance with this requirement(s) the vendor shall submit either a formal report from an independent laboratory or a confidential, notarized, legallybinding manufacturer s report indicating the method used and the laboratory results obtained for the specific brand submitted for certification. C. QUALITATIVE REQUIREMENTS: 1. COLOR: The color of the paint is white and tintable to at least medium color tones, as specified in the contract or purchase order and shall match that of the standard color chip. 2. STORAGE STABILITY IN A PARTIALLY FULL CONTAINER: The paint shall show no skinning after 48 hours when tested as specified in III-D. After an additional 14 day-period at 120 F, the same sample shall show no skinning, livering, curdling, hard caking, or gummy sediment. It shall mix readily to a homogenous state and the change in viscosity, compared to the original, shall not be greater than 10 K.U. 3. STORAGE STABILITY IN UNOPENED CONTAINER: All containers shall have sufficient preservatives to prevent spoilage for one year. 4. ODOR: The odor should not be putrid during or after application, however, a slight inoffensive ammonia odor during application is acceptable but shall dissipate with ventilation after application. 5. ALKALI RESISTANCE: The paint film, tested as in III-A, shall show no change in hue and not more than very slight changes in reflectance and gloss. 1 10 25 2.0 3.5 7.0 8 25 55 Page 2

6. MATERIAL SAFETY DATA SHEET (MSDS): An MSDS clearly identifying this product, filled out completed according to the Florida-to-Know Law, Chapter 442, Florida Statute must be submitted with each sample submitted for certification. 7. CONDITION IN CONTAINER: The paint, when tested as specified in Table II, shall be free from grit, seeds, skins, lumps, and livering, and shall show no more pigment settling or caking than can be reincorporated into a smooth homogenous state. In a freshly opened container, there shall be no rusting on the container. 8. FLEXIBILITY: When tested as specified in III.B, there shall be no cracking, chipping or flaking. 9. SAG RESISTANCE: The paint shall have a minimum anti-sag index of 7.0 when tested as specified in III-F. 10. SCRUBBABILITY: When tested as specified in III.C., the number of cycles needed to remove the paint film fully in one continuous thin line across the shim cannot be less than 1000 cycles (2000 strokes). D. SURFACE PREPARATION: 1. As surface preparation is critical to the performance of mold & mildew preventative coatings, surfaces must be clean, sound, and free of dirt, dust, grease, wax, wallcovering adhesive, soap film, loose paint or other surface contamination. All existing mold and mildew should be removed before painting as per the appropriate EPA guidelines (See http://www.epa.gov/iaq/molds/moldsresources.html). III. TEST PROCEDURES FOR LABORATORY ANALYSIS The failure of any test in this section shall constitute a failure of the product to conform to the specification. Unless otherwise noted, all test methods cited are the latest published revision. PHYSICAL AND CHEMICAL PROPERTIES: The physical and chemical tests to be performed are shown in Table II as well as the standard methods they should be conducted in accordance with. A. ALKALI RESISTANCE: Apply the test paint by draw-down to obtain a dry film of 2.0 ( + / - 0.2) mil thickness on a Leneta plastic scrub panel (P-121-10N). Allow to air dry for 120 hours after the application of the paint. Place 5 drops of 2% (w/v) aqueous sodium hydroxide solution on the paint and immediately cover the surface with a 50 mm watchglass. After 2 hours, remove the watchglass and wash off the solution. Allow 2 hours for recovery and examine for compliance with II-C-5. B. FLEXIBILITY: Prepare the test panel in accordance with Method 2012.2 of Fed. Test Method Standard No. 141C. Supplement the test panel cleaning procedure with an additional cleaning with abrasive soap (such as Bon Ami or equal) so that the entire surface of the panel is wet. Apply the paint in accordance with Method 2162 of Federal Test Method Standard No. 141C on the clean, dry panel with a 0.003-inch (approximately 0.006-inch gap Page 3

clearance) Bird film applicator or similar blade which produces the same film thickness. Air dry for 18 hours, bake for 3 hours at 105(+2) 0 F, then cool for 1/2 hour. Bend over a 1/8- inch mandrel and examine in accordance with Method 6221 of Federal Test Method Standard No. 141C for compliance with II-C-8. C. SCRUBBABILITY: Test according to ASTM D 2486 except that 50 ml. of water is used instead of 5. Check for compliance with II.C.10. Test TABLE II. TEST AND METHODS Methods 1. Condition in container FTM Std. 141C, Method 3011.2 2. Skinning FTM Std. 141C, Method 3021.2 3. Total Solids, % by wt. of paint ASTM D-2369 4. Consistency, Krebs-Stormer ASTM D-562 5. Drying time (Set-to-Touch, Dry Hard) ASTM D-1640 6. Weight per gallon ASTM D-1475 7. Reflectance ASTM E 97 8. Opacity ASTM D 2805 9. 60 o Gloss (%) ASTM D 523 10. Fineness of grind ASTM D 1210 11. Flash Point ASTM D 56 12. Scrubbability ASTM D 2486 13. Sag Resistance ASTM D 4400 14. Mold Resistance Tests ASTM D3273 & ASTM D5590 (Note: See Table III below) 15. Nonvolatile matter (% by volume) ASTM D 2697 D. STORAGE STABILITY IN PARTIALLY FULL CONTAINER: Determine skinning after 48 hours in accordance with Federal Test Methods Std. 141C, Method 3021.1, except use a ¾ filled 1- pint, multiple friction-top can. Then reseal and store for 14 days at 120 0 F, check for compliance with II-C-2. E. EFFICACY TO MOLD AND MILDEW: The manufacturer must submit a certification from an independent laboratory stating that the received samples meet the acceptance criteria included in Table III: Resistance of paint films to fungal defacement: Agar Plate TABLE III. TESTS, METHODS, QUANTITATIVE RESULTS Test Methods Acceptance Criteria ASTM D5590. Must include addition of Stachybotrys Charatrum (see Page 2, note 3 of test description) and leach testing (see page 3, Note 8) leached and unleached Resistance to Mold on ASTM D3273 Minimum Rate: 8 <2 Page 4

the Surface of Interior Coatings (Evaluated per ASTM D3274-00) Note: When priming is required a mold & mildew preventative primer must be used. Some mold & mildew preventative coatings are self-priming. Check manufacturer specification or technical sheet. F. SAG RESISTANCE: Mount a sealed Morest or Leneta test chart on a vacuum plate of an automatic film applicator. Set the Leneta Anti-Sag Meter at the top of the test chart with the open side of the blade facing the operator. Place a suitable quantity of the paint directly in front of the blade, and draw down the paint. The completed draw down shall then be immediately removed from the automatic film applicator and placed in a vertical position with the stripes horizontal and the thinnest stripe at the top. Allow to dry at room temperature in this position and then determine the Anti-Sag Index as per ASTM D 4400. IV. METHODS OF SAMPLING, INSPECTION AND OTHER TESTS A. SAMPLING: At the option of the purchaser, representative samples shall be taken from randomly chosen shipments and submitted for quality control testing. If the purchaser s sample fails, the manufacturer shall pay for the actual cost of testing. Failure of any sample so taken to comply with the specification requirements shall invalidate any purchase contract unless the manufacturer requests a repeat quality control test. This second sample shall be from the same batch. The manufacturer shall pay for the second quality control test should the sample fail, and this invalidates any future purchase contracts. If the second sample passes, the manufacturer is not responsible for paying the actual cost of the test and the results obtained from the second quality control test shall prevail. B. INSPECTION: Physical inspection of package, condition, quantity, and labeling shall be made at point of delivery by the purchaser. MSDS shall be submitted with each shipment in accordance with the Florida Right-to-Know Law, Chapter 442, Florida Statutes, and shall be identical to the MSDS supplied for initial certification. NOTE: TESTING TO MEET THIS SPECIFICATION DOES NOT INCLUDE AN IN-USE PERFORMANCE TEST. ALL EDUCATIONAL AGENCIES SHOULD CONSIDER AN IN-USE PERFORMANCE TEST BEFORE PURCHASING THIS PRODUCT. ORIGINAL APPROVED by FSPMA Paint Committee on August 15, 2005. REVISION 47.1 EFFECTIVE March 10, 2006 REVISION 47.2 EFFECTIVE September 16, 2008 PRESIDENT FLORIDA SCHOOL PLANT MANAGEMENT ASSOCIATION CHAIR FSPMA CUSTODIAL/FOOD SERVICE CHEMICAL SPECIFICATION COMMITTEE Page 5