Energy efficiency of a solar domestic hot water system

Similar documents
Investigations of thermal self-sufficient Residential Buildings with Solar Energy Systems

Available online at ScienceDirect. Energy Procedia 91 (2016 )

SIMULATION OF A SOLAR WATER HEATING SYSTEM

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

DESIGN AND RECOMMANDATIONS FOR DECENTRALIZED SOLAR DISTRICT HEATING SYSTEMS IN FRANCE

Solar hot water systems in new housing

use Solar thermal for hot water production

use Solar thermal for hot water production DESIGN APPROACHES

AR No. # - Solar Thermal

EVALUATION OF A HIGH TEMPERATURE SOLAR THERMAL SEASONAL BOREHOLE STORAGE

Design and optimization of solar water heating system for a five star hotel in Varanasi

SIMULATION MODEL IN TRNSYS OF A SOLAR HOUSE FROM BRAŞOV, ROMANIA

DESIGN AND MODELING THE Φ-F

Reference System, Austria Solar Domestic Hot Water System for Single-Family House

Mathematical Modeling of Basic Parts of Heating Systems with Alternative Power Sources

Computational and the real energy performance of a single-family residential building in Poland an attempt to compare: a case study

Identified technologies for the InfraSUN pilot plant

Life cycle analysis of thermosyphon solar water heaters

RESEARCH OF SOLAR WATER HEATERS MODEL

DEVELOPMENT OF A SOLAR COLLECTOR/SOLAR WATER HEATING SYSTEM TEST CENTER IN IRAN

Advances in Engineering Research, volume 103 Proceedings of the 3rd International Conference on Material Engineering and Application (ICMEA 2016)

Evaluation of efficiency and collector time constant of a solar flat plate collector

Report On Task 57, Subtask B1: Development of Accelerated Ageing Tests for Evacuated Tube Collectors

Baltimore County Detention Center Expansion Towson, Maryland

EFFICIENT SOLAR COOLING

Feasibilty of Wind-Solar Hybrid System for Cleveland, Ohio, USA

System-Level Design Review Solar Thermal Water Heater. Mike Pastore, Evan Baileys, Deven Greenawalt, Alex Slabyk, Sarah Kirk

The Fast and. Professional. Simulation Programme for the Design and Optimisation of. Heating Systems T SOL. Version 4.x. Professional.

Reference System, Germany Solar combi system for DHW* preparation and space heating

Solar Flat Plate Thermal Collector

SorTech package solution description

Thermo-hydraulic Design of Solar Collector Networks for Industrial Applications

Available online at ScienceDirect. Energy Procedia 70 (2015 )

ST-4 Polygeneration plant. Parc de l Alba Cerdanyola del Vallès

International Journal of Mechanical Civil and Control Engineering. Vol. 1, Issue. 3, June 2015 ISSN (Online):

Technical Guide to Solar Thermal. Better World Energy. How to harness the sun s energy and create hot water with a Solar Thermal System

Solar Thermal Systems for Residential Homes

On the Night Heat Losses in Thermosyphon Solar Water Heaters

Camel Solar brings you some of the most advanced solar thermal systems available on the market today through innovation, research and development.

Reference System, Germany Solar Domestic Hot Water System for Single-Family House

Solar Thermal Explained... Barilla Solar. Presented by Karl Thorne

Borehole Field in the The Drake Landing Solar Community Okotoks, Alberta

Solar Installers Note: Guidance on Achieving Compliance with the Better Energy Homes Programme. March 2012

Feasibility of using an augmenting solar array for a greenhouse in NW Ohio

ALONE. small scale solar cooling device Project No TREN FP7EN Project No TREN/FP7EN/ ALONE. small scale solar cooling device

Simulation and economic analysis of solar cooling for building in tropical climate of Surabaya, Indonesia

FIRST LARGE-SCALE SOLAR SEASONAL BOREHOLE THERMAL ENERGY STORAGE IN CANADA

An Introduction to Planning Solar Water Heating Systems

Microgeneration Technology Performance in the Irish Housing Stock

1/60. Solar systems. solar system layouts heat demand collector area calculation

AR No. # Solar Thermal. Assessment Recommendation Savings Summary Source. Cost Savings Natural Gas. $984 * 1 MMBtu = 1,000,000 Btu

Renewables. Vacuum Tube Solar Systems. Solar Energy to the Power of

Asian Journal on Energy and Environment ISSN Available online at

SOLAR THERMAL INSTALLATIONS FOR HOT WATER PRODUCTION IN THE HOTEL COMPLEX DOBRUDZHA ALBENA RESORT

The impact of hot and cold storages on a solar absorption cooling system for an office building

COMPLETE TEST FACILITY FOR SOLAR THERMAL COLLECTORS AND SYSTEMS

Research on integrated solar and geothermal energy engineering design in hot summer and cold winter area

Application of solar cooling system in a campus library in Hainan, China

Energy efficiency of buildings from Europe to Slovakia

Thermal Analysis of Solar Flat Plate Collector

Solar Calculations for the Raseiniai District Heating Plant

Guidance page for practical work 1: modeling of a thermodynamic solar plant

Reminder: Solar and Terrestrial Radiation

EINSTEIN. Del.No7.3: Report on impact assessment of demonstration plants THERMAL ENERGY STORAGE SYSTEMS IN EXISTING BUILDINGS

Modeling and simulation of a reclaimed water source heat pump system based on TRANSYS 1

Comfort. Warm, Radiant. in the Sand. Floor heating systems that store the sun s energy in sand offer warmth through the cloudy winter.

Reference System, Austria Solar Domestic Hot Water System for Single-Family House

Effect of Distance between Double Glazing on the Performance of a Solar Thermal Collector Control

Unit 7 Overview of Solar Thermal Applications

Report Solar Site Visit

Modeling and analyzing solar cooling systems in Polysun

Reference System, Austria Solar Domestic Hot Water System for Multi-Family House

Available online at ScienceDirect. Energy Procedia 70 (2015 )

Microgeneration Installation Standard : MCS 024 SOLAR DOMESTIC HOT WATER ENERGY CALCULATION. to be used in conjunction with MIS 3001:

Module Title: Building Services Mechanical 2

MEASURED AND SIMULATED PERFORMANCE OF A HIGH SOLAR FRACTION DISTRICT HEATING SYSTEM WITH SEASONAL STORAGE

Deep thermomodernization of three residential buildings in Kryvyi Rih, Ukraine

Modeling and Simulation of Energy Use and Indoor Thermal Environment of Highly-Insulated Buildings

Reference System, Austria Solar domestic hot water system for single- family house

Reference System, Germany Solar domestic hot water system, single-family house

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Application of Solar Heating on the Electrolyte Conditioning for Electrowinning Process: Thermosolar Plant Performance

Reminder: Solar and Terrestrial Radiation

Solar thermal energy: A promising source for Energy Intensive Industries

Heat pumps. WP5 Education and Economic Promotion

The Design and Sizing of Active Solar Thermal Systems

Reference System, Austria Solar domestic hot water preparation for multi- family house

Calculation and Fabrication of a Solar Flat Plate Collector Efficiency using Mild Steel as Absorber Plate

Comparative Heating Performances of Ground Source and Air Source Heat. Pump Systems for Residential Buildings in Shanghai

Helping Building Services Engineers Apply Low Carbon Technologies

Active Solar Thermal Energy Applications in Buildings (Part 2)

Available online at ScienceDirect. Procedia Engineering 146 (2016 )

Nocturnal radiation cooling tests

Simulation of Solar Thermal Cooling System for an Office Building in Indian Climates using Evacuated Tube Collector

Building performance based on measured data

CCR3 Controller - return temperature controller & temperature registration

Reference System, Austria Solar combisystem system, single-family house

SOLAR COMBISYSTEMS IN DENMARK SOLAR & BIOMASS SYSTEMS

A Software for Performance Simulation of Solar Water Heating Systems

The efficiency of the heat pump water heater, during DHW tapping cycle

Transcription:

Energy efficiency of a solar domestic hot water system Miroslaw Zukowski 1,* 1 Bialystok University of Technology, Department of HVAC Engineering, ul. Wiejska 45E, 15-351 Bialystok, Poland Abstract. The solar domestic hot water (S) system located on the campus of Bialystok University of Technology is the object of the research described in the current paper. The solar thermal system is composed of 35 flat plate collectors, 21 evacuated tube collectors and eight hot water tanks with the capacity of 1 m 3 of each. Solar facility is equipped with hardware for automatic data collection. Additionally, the weather station located on the roof of the building provides measurements of basic parameters of ambient air and solar radiation. The main objective of Regional Operational Program was the assessment of the effectiveness of this solar energy technology in the climatic conditions of the north-eastern Poland. Energy efficiency of S system was defined in this research as the ratio between the useful heat energy supplied to the domestic hot water system and solar energy incident on the surface of solar panels. Heat loss from water storage tanks, and from the pipe network to the surrounding air, as well as the electrical energy consumed by the pumps have been included in the calculations. The paper presents the detailed results and conclusions obtained from this energy analysis. 1 Introduction Economic assessment of energy-conversion systems is quite complex. The long-term energy efficiency is the key factor of this analysis. Experimental studies carried out on the existing and operating facilities will allow to develop the energy balance of the whole solar system in a very accurate way. Unfortunately, this procedure is quite expensive. As it turned out, the additional cost of the monitoring and automatic data collection (ADC) of operating parameters of the solar domestic hot water (S) system tested by the author, was equal about 2/3 of the cost of materials and installation of the solar system. For this reason, experimental studies to evaluate the energy efficiency of medium and large solar installations are not often performed. A large number of actual data from field-testing and monitoring of domestic solar hot water systems in China have been analysed by Yao et al. [1]. They discovered that there are many problems resulting from the relatively large amount of measurement error and use of different methodologies for assessing and monitoring. The authors proposed the methods and indicators for precise estimation of solar hot water systems. * Corresponding author: m.zukowski@pb.edu.pl The Authors, published by EDP Sciences. This is an open access article distributed under the terms of the Creative Commons Attribution License 4.0 (http://creativecommons.org/licenses/by/4.0/).

The results of evaluation of water heating system supported by 640 m 2 of solar collectors installed on high-rise housing complex in South Korea have been presented by Yoo in [2]. Unfortunately, as it turned out, the total energy gains from three years of S operation is lower by a half of the design assumptions. A wide gap between theory and practice can be observed in this case. Analysis of measurement results have shown that the collector efficiency ranges from 42% in August to 53% in April. Unfortunately, the author has not performed an assessment of the energy efficiency of this large solar facility. A solar domestic hot water system installed on a one-family house in Dublin (Ireland) has been tested by Gill et al. [3]. Based on the analysis of the annual results of experimental research the overall efficiency of the solar system has been estimated at about 63%. It should be noted that the key components of heat loss have been taken into account by the authors of this study. Several studies have investigated the energy and economic efficiency of the whole S system using some simplifications. For example, solar collectors are treated as the only part of the installation that generates heat loss. Some selected studies of this kind are presented below. Stevanovic and Pucar [4] have estimated the performance of solar water heating system with the f-chart method. The results of theoretical analysis have been used to determine the level of the subsidy should be offered by the Serbian government to increase the popularity of renewable energy sources (RES) in this country. The energetic, economic and environmental impacts of different types of water heating systems for the USA typical residential buildings located in Los Angeles, Atlanta, and Chicago have been investigated by Hang et al. [5]. Unfortunately, the performance of solar water heating systems has been determined only based on the thermal characteristics of the flat-plate (efficiency 55%), and evacuated-tube (efficiency 59%) solar collectors provided by the manufacturer. Lin et al. [6] have developed a procedure for estimating the payback period of residential S system. Daily solar radiation and hot water consumption pattern per person have been taken into account in the calculation of annual energy gains for case study in southern Taiwan. The analysis has assumed that the thermal efficiency of the collectors (do not exceeding 40%) is equivalent to the performance of the whole system. Fifteen different energy supply systems for single family houses in the northern European climate conditions have been analysed by Dziugaite-Tumeniene et al. [7]. The theoretical analysis made by the authors has been based on the integrated assessment model of an energy supply system for an energy-efficient building (ESSINTEGRA). Using this method has allowed to obtain energy efficiency (equal to 31%) of the system consisting of the wood boiler and solar collectors. Based on the literature review, it can be concluded that there are not much information on the research projects related to the experimental evaluation of the energy efficiency of medium solar systems used for domestic water heating. Thus, the author hopes that this paper will contribute to increase the knowledge on this important issue and provide the necessary data to design and economic analysis of S systems. 2 Description of the research object Regional Operational Program of Podlaskie Voivodeship on the practical application of renewable energy technologies were being implemented at the Bialystok University of Technology (BUT) in the years 2013 2015. One of the practical results of this project was installation of the solar domestic hot water system (S). Solar facility is located on the roof of the Hotel for Research Assistants on BUT campus in Bialystok (Fig. 1). The solar thermal system is composed of two parallel-connected subsystems: the first includes of 2

35 flat plate collectors (FPCs), connected in series of 5 units in one section, with a total area A FPC of about 72 m 2 (65.5 m 2 aperture area), and the second consists 21 evacuated tube collectors (ETCs), connected in series of 3 units in one section, with a total area A ETC of more than 74 m 2 (67m 2 active area). Eight tanks with the total capacity of about 8 m 3 are used to store the hot water heated by the solar thermal panels. Fig. 1. Flat plate solar collectors connected in series of 5 units in one section (left side of the fig.), and evacuated tube solar collectors connected in series of 3 units in one section (right side of the fig.). Solar facility is equipped with hardware for automatic data collection. The following elements are included in the data capture system: 17 heat meters, 4 electricity meters used for recording electric energy consumption of pumps, and 42 PT 500 platinum resistance temperature sensors for monitoring of the temperature distribution in the whole system. Additionally, the weather station located on the roof of the hotel provides measurements of the basic parameters of ambient air and solar radiation. All the data collected by the ADC system are readily available via the Internet. The simplified scheme of the hydraulic circuits of the solar system are shown in Fig. 2. Fig. 2. Simplified diagram of the S system with the location of measuring instruments and sensors. 3

3 Energy efficiency of a solar domestic hot water system The main objective of the previously mentioned Regional Operational Program was the assessment of the effectiveness of solar water heating technology in the climatic conditions of the north-eastern Poland. Energy efficiency of S system SYS has been defined in this research based on Eq. (1) as the difference between the useful heat energy supplied to the tap water system in the hotel E and electrical energy consumed by the pumps E P divided by solar energy incident on the solar panels E SOL. As mentioned earlier, ultrasonic heat meters have been utilised to obtain the value of thermal energy in 17 points at the system. Relative measurement error of these devices is small, and according to the manufacturer's information, is only 2%. The data recorded by heat meters have been used to prepare the energy balance. The study covered the period from 1 May 2015 to 30 November 2016. E nm m 1 E EP SYS 100 (1) E SOL T T c T T nd 24 3600 c (2) p FPC CW p ETC CW E SOL nm q nd 243600 1 SOL A FPC A ETC (3) where: nm number of months, m mass flow rate [kg/s], nd number of days in a month, c p heat capacity of water [J/kg/K], T FPC temperature of the water flowing from the tanks supplied by FPCs [K], T CW temperature of the cold water [K], T ETC temperature of the water flowing from the tanks supplied by ETCs [K], q SOL solar radiation flux that is incident on the collector surface [W/m 2 ]. The weather station is located very close to the collectors and total solar radiation sensor is set at the same angle as the panels i.e. 40. The sampling frequency of the weather parameters is equal to 5 seconds, and other parameters of the system are collected in oneminute time steps. Therefore, it was necessary to average all the results of measurement on a one hour interval. Then, the results have been summed to provide energy gain, energy consumption in the case of pump operation, and hot water consumption within one month period. Solar radiation energy E SOL that is incident on the two sets of solar collector surfaces of the total area 146.29 m 2 has been calculated using Eq. (3). The total amount of E SOL from 1 May 2015 to 30 November 2016 was equal 1029.72 GJ. Next, the amount of useful energy gain coming from both arrays of the solar collectors E SC has been determined based on the data recorded by heat meters placed in the substation on the roof. During the reporting period of 19 months the solar collectors provided 397.98 GJ of thermal energy, of which 204.09 GJ has been produced by flat plate collectors, and 193.89 GJ by evacuated tube collectors. The bar chart in Fig. 3 shows that the ETCs (much more technologically advanced) have been characterized by higher power only in the cold season from October to March. Unfortunately, at this period of the year duration and intensity of solar radiation is very low. Heat losses to the environment from flat plate collectors are usually higher compared to from evacuated tubes. However, the overall balance has shown that FPCs produced 5% more energy during the whole analysed time period. Part of this energy has been lost. The vast majority of sources of energy loss are outlined on the block diagram shown in Fig. 4. 4

E SC [GJ] 20 15 FPC ETC 10 5 0 Fig. 3. Solar energy converted into thermal energy by solar panels. Fig. 4. Energy balance of the S system. The closed loop solar system under the analysis is divided into primary and secondary circuits, that are separated by heat exchangers. Hence, such a system must be fitted with four pumps, two for each of the collector arrays. All pumps consumed 8.69 GJ of electricity E P in the period under consideration. This value has reduced energy gain from the solar system. The pumps located in the ETCs closed loop system consumed about 5.5% more of electric energy compared to FPCs system. As can be observed in Fig. 5, this trend intensified during the winter. 5

E P [GJ] FPC pumps ETC pumps 0,35 0,30 0,25 0,20 0,15 0,10 0,05 0,00 Fig. 5. Consumption of electric energy by the pumps by months. The useful heat energy supplied to the domestic water system E has been calculated separately for each type of solar panel sub-systems based on Eq. (2) and was equal 344.52 GJ. Then, seasonal energy efficiency of the whole S system has been estimated using the relation given in Eq. (1). Fig. 6 shows the SYS taken separately for each month during the entire study period. As can be observed, in the warmer months from April to August, the efficiency was the highest and most often exceeded 35%. In the winter SYS was significantly decreasing and even it dropped up to 10% in January 2016. 40 SYS [%] 35 30 25 20 15 10 5 0 Fig. 6. Energy efficiency of the S system by months. Eight hot water storage tanks, the hot water pipelines connecting substation on the roof with the second substation in the basement (average length of each of the four DN40 pipes is 86 m), flow control fittings and shut-off valves turned out to be the major sources of energy loss E LOSS. Detailed analysis of the different sources of heat loss was not the main 6

subject of this study. They have been taken as a total. The value of E LOSS was equal 53.46 GJ and has been obtained as the difference between E SC and E. This was only 13.4% of energy gain coming from the solar collectors. The parameter which indicates what part of energy is provided by the solar system and what must be supplied by an additional power source is a solar fraction SF. This value is determined by the following formula [8]: E SF (4) E E AUX The auxiliary energy demand was calculated according to Eq. (5), assuming the design value for hot water temperature T equal to 60 o C. E AUX nm m 1 T T c T T nd 24 3600 c (5) p As shown in Fig. 7, S system was able to satisfy around 35% of the hot water demand during the warmer months. However, in winter time, this factor decreased to only about 5%. The monthly average SF in the period under consideration was 23.4%. Usually it is assumed that a well-designed solar system should be able to provide around 40% of total energy load for water heating [9]. It proves too small area of solar collectors used in this system. Unfortunately, in medium-rise buildings (5 to 15 storeys) often there is a lack of space on the roof to allocate additional solar panels. FPC p ETC 0,40 SF [-] 0,35 0,30 0,25 0,20 0,15 0,10 0,05 0,00 Fig. 7. Changing the monthly average value of the solar fraction. 4 Conclusions and the future work The main goal of the present research has been to determine the seasonal energy efficiency of the solar domestic hot water system located on the campus of Bialystok University of Technology. This study involving analysis of measurement data that have been collected from 1 May 2015 to 30 November 2016. It has been found that the energy efficiency of S system was strongly related to the intensity of solar radiation. As indicated by the calculation results SYS was equal 32.6% 7

for the time period of this analysis, with 34.7% in the warmer months and 24.2% during the colder months (period from October 2015 to March 2016). To summarize, it can be concluded that only about 1/3 of the solar energy that falls on the solar panels has been converted into useful heat supplied to the domestic hot water system. So, this level of energy efficiency can be applied to any type of economic evaluations associated with the use of solar collectors for water heating in similar types of buildings in areas with a similar climate to north-eastern Poland. It is planned that the study on the effectiveness of S system will be continued for the next three years. Besides, the thermal performance of both types of solar collectors according to the standard ISO 9806:2013 will be determined. This work has been performed within the framework of a Grant of Bialystok University of Technology (Grant No. S/WBIIS/4/2014). References 1. C. Yao, B. Hao, S. Liu, X. Chen, Energy Procedia, 70 (2015) 2. J.-H. Yoo, Energy and Buildings, 101 (2015) 3. L. Gill, J.M. Mahon, K. Ryan, Solar Energy, 137 (2016) 4. S. Stevanovic, M. Pucar, Energy and Buildings, 54 (2012) 5. Y. Hang, M. Qu, F. Zhao, Energy and Buildings, 45 (2012) 6. W.M. Lin, K.C. Chang, K.M. Chung, Renewable and Sustainable Energy Reviews, 41 (2015) 7. R. Dziugaite-Tumeniene, V. Motuziene, G. Siupsinskas, K. Ciuprinskas, A. Rogza, Energy and Buildings, 138 (2017) 8. The German Solar Energy Society, Planning and installing solar thermal systems: A guide for installers, architects and engineers, James and James, UK (2007) 9. Y. Evans, T. Dwyer, CIBSE Journal, 02 (2009) 8