Daniel TM Ultrasonic Flow Meters

Similar documents
Daniel Orifice Fittings and Meter Tubes

DANIEL MODEL 1760 BACK PRESSURE PILOT

Brooks Mass Flow Meter Model 5863 Mass Flow Controller Model 5853

DANIEL LIQUID TURBINE METER REMOTE MOUNTING BOX

1. DEFINITIONS 2. ORDERS, PRICES AND FEES

Keysight 16380C Capacitance Standard Set

S8VM Series Replacement Brackets

Qualstar Technical Support

TERMS AND CONDITIONS OF SALE

TrueClean ToteTilter TM

PalletPal Low Profile Disc Turntable

Dandy Leveler UDLV-150 & UDLV-500 (New Style)

User Guide M Rev A 09/15

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

WARNING. Introduction ! ATTENTION

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

Agilent 16047D Test Fixture

Stretch Wire. P/N Rev. 2. IOM Stretched wire festoon manual

General Information. Southwest Office Edwards Road, Suite B105 Cerritos, CA (Main Phone)

SEAMLESS STEEL PIPE NIPPLES

Mechanical Post Lift. Owner s Manual

1.1 Defined Terms. As used in this Policy, the following terms have the indicated meanings:

Siklu Service&Support Plans

Smart-UPS X-Series External Battery Pack Installation and Operation

Agilent 16034E Test Fixture

Process Returns in VOTW

REF DOC # STANDARD IMAGING, INC Murphy Drive Middleton, WI TEL TEL FAX

TABLE OF CONTENTS. Section Paragraph Title Page. ADDENDUM Visual Index Quick Reference. 1 General Information 1-1

E3X-DRT21/SRT21/CIF11

HATCHSAFE Installation Instructions/Operation and Maintenance Manual Models: All Models

Agilent 16048B Test Leads Operating Note Third Edition Agilent Part No May 2000

PAIRED LADDER SAFETY GATE Installation Instructions/Operation and Maintenance Manual

SAVE THESE INSTRUCTIONS

Agilent 16048D Test Leads

Micro Motion, Inc Winchester Circle Boulder, CO (800)

STEEL PIPE NIPPLE DISCOUNT SHEET

EP100 EMERGENCY POWER BANK

Instructions for Use Reprocessed Electrophysiology Catheter Cables

4 rotary milling table

8 DIAL CALIPER. Model Diagrams within this manual may not be drawn proportionally.

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

MAINTENANCE AGREEMENT FOR RSA PRODUCTS ***IMPORTANT***

RAPiD Safe Setup and Operation

SelfCheck System R-Series. Site Planning Guide

CDM Network Programmer for CCT100x

Sensors Temperature, Humidity, Light, Barometric pressure, Sound noise, 3-axis acceleration *1, etvoc *2

Beach House Cargo Lifts Branded Product of Cargo Lift Distributors

Pallet Gate Installation Instructions and Operators Manual

Low-Level Design Validation and Testing

APC Step-Down Transformer. Models: AP9626, AP9627, and AP9628

Aero Tec Models 700 & 750 (115 vac)

OWENS CORNING Limited Lifetime Warranty for EnergyComplete System. OWENS CORNING Limited Lifetime Warranty for EnergyComplete Sealant

92831 TEL: (714) FAX:

Owner s Manual & Safety Instructions

Odoo Enterprise Subscription Agreement

Double-Drum Forklift Gripper

55-Gallon Tilting Drum Ring

66-Bin Wire Shelf Storage Rack

TERMS AND CONDITIONS: (Stated in U.S. Dollars):

VILLAGIO FLOORS, INC. TOLL FREE: Fax: VILLAGIOWOODFLOORS.COM. Finish Warranty. Structural Warranty

DRUM-GRAB INSTRUCTION MANUAL

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

VHSR-SERIES RACKS FOR SHEET MATERIAL

Instructions for Use Reusable Electrophysiology Catheter Cables

Installation Instructions/Operation and Maintenance Manual. Models PLG-60 PLG-72. PS DOORS Contact Information. Website psdoors.

Festoon Manual Stretch Wire

OPERATION AND MAINTENANCE MANUAL. (For Owner s Use Only)

Machinery Mover. Owner s Manual

TAYLOR FORGE STAINLESS

CLASS 150 AND XH STAINLESS STEEL PIPE FITTINGS

117-Bin Wire Shelf Storage Rack

GE Enduris* 3500 silicone roof coating Roof Restoration Warranty - 10 Year

CLASS 150 AND XH STAINLESS STEEL PIPE FITTINGS

This product has been tested and certified to conform to ASTM F2456, Youth Resistant Firearms Container.

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

Heavy-Duty Aluminum Arched Ramps 10,000-Lb. Capacity Per Pair.

Festoon Manual Heavy Duty C-Track

OPERATION AND INSTALLATION MANUAL

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

Elevation Station MODEL: ES.02-16

AXIS T91G61 Wall Mount

SPS2-SERIES STOCKPICKER HAND TRUCKS INSTRUCTION MANUAL

END TRUCKS WHEEL SIZES: 9", 12", 15" & 18"

H8SX/1650 Series E6000H TFP-120 User System Interface Board User s Manual HS1650ECN61H

Products. Standard Terms, Conditions, Policies and Procedures Guide. Residential Garage Door Openers and Accessories

Aluminum Bi-Fold Pet Ramp

Instructions and E00 Series Sampling Module Extenders

ALUMINUM CURB RAMP. Model 98037

UNIVERSAL UTILITY TRUCK RACK

Pallet Puller. Owner s Manual

Drag Chain Conveyor Installation and Operation Manual

TERMS AND CONDITIONS May 15, 2017

Warranty & Terms and Conditions

Owner s Manual Shelf Lip Accessory

Instructions for Use Reusable Ablation Catheter Cables

Quick Start Guide WaveMaster

Y SIDE ALUMINUM TRUCK RACK

STEEL PIPE NIPPLES SEAMLESS Price Sheet PNS-9.16C Effective: September 5, 2016 Cancels Price Sheet PNS-10.15C of October 5, 2015

Mobile Drum Carrier. Owner s Manual

Warranty & Terms and Conditions

Transcription:

Installation and Operating Instructions Manual Part Number 3-9000-745 Revision F August 2017 Daniel TM Ultrasonic Flow Meters Installation and Operating Instructions Specific to the Pressure Equipment Directive 3400 Mark III Gas Ultrasonic Meter 3800 Mark III Liquid Ultrasonic Meter 3410 Series Gas Ultrasonic Meter 3810 Series Liquid Ultrasonic Meter

Daniel customer service Location Telephone number Fax number North America/Latin America +1.713.467.6000 +1.713.827.4805 Daniel Customer Service +1.713.827.6314 +1.713.827.6312 USA (toll free) +1.888.356.9001 +1.713.827.3380 Asia Pacific (Republic of Singapore) +65.6777.8211 +65.6777.0947.0743 Europe (Stirling Scotland, UK) +44 (0)1786.433400 +44 (0)1786.433401 Middle East Africa (Dubai, UAE) +971 4 8118100 +971 4 8865465 E-mail Customer Service: tech.service@emersonprocess.com Customer Support: daniel.cst.support@emerson.com Asia-Pacific: danielap.support@emerson.com Europe: DanielEMA.CST@EmersonProcess.com Return Material Authorization (RMA) A Return Material Authorization (RMA) number must be obtained prior to returning any equipment for any reason. Download the RMA form from the Support Services web page by selecting the link below. www2.emersonprocess.com/en-us/brands/daniel/support-services/pages/support-services.aspx?

Signal words and symbols Pay special attention to the following signal words, safety alert symbols and statements: Safety alert symbol This is a safety alert symbol. It is used to alert you to potential physical injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death. Danger indicates a hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates a hazardous situation which, if not avoided, could result in death or serious injury. Caution indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Notice is used to address safety messages or practices not related to personal injury. Important Important is a statement the user needs to know and consider. Tip Tip provides information or suggestions for improved efficiency or best results. Note Note is a general by-the-way content not essential to the main flow of information.

Important safety instructions Daniel Measurement and Control, Inc. (Daniel) designs, manufactures and tests products to function within specific conditions. Because these products are sophisticated technical instruments, it is important that the owner and operation personnel strictly adhere both to the information printed on the product and to all instructions provided in this manual prior to installation, operation, and maintenance. Daniel also urges you to integrate this manual into your training and safety program. BE SURE ALL PERSONNEL READ AND FOLLOW THE INSTRUCTIONS IN THIS MANUAL AND ALL NOTICES AND PRODUCT WARNINGS. Installing, operating or maintaining a Daniel product improperly could lead to serious injury or death from explosion or exposure to dangerous substances. To reduce this risk: Comply with all information on the product, in this manual, and in any local and national codes that apply to the product. Do not allow untrained personnel to work with this product. Use Daniel parts and work procedures specified in this manual. Product owners (Purchasers): Use the correct product for the environment and pressures present. See technical data or product specifications for limitations. If you are unsure, discuss your needs with your Daniel representative. Inform and train all personnel in the proper installation, operation, and maintenance of this product. To ensure safe and proper performance, only informed and trained personnel should install, operate, repair and maintain this product. Verify that this is the correct instruction manual for your Daniel product. If this is not the correct documentation, contact Daniel at 1-713-827-6314. You may also download the correct manual from: http://www.daniel.com Save this instruction manual for future reference. If you resell or transfer this product, it is your responsibility to forward this instruction manual along with the product to the new owner or transferee. ALWAYS READ AND FOLLOW THE INSTALLATION, OPERATIONS, MAINTENANCE AND TROUBLESHOOTING MANUALS AND ALL PRODUCT WARNINGS AND INSTRUCTIONS. Do not use this equipment for any purpose other than its intended service. This may result in property damage and/or serious personal injury or death.

Product Operation Personnel: To prevent personal injury, personnel must follow all instructions of this manual prior to and during operation of the product. Follow all warnings, cautions, and notices marked on, and supplied with, this product. Verify that this is the correct instruction manual for your Daniel product. If this is not the correct documentation, contact Daniel at 1-713-827-6314. You may also download the correct manual from: http://www.daniel.com Read and understand all instructions and operating procedures for this product. If you do not understand an instruction, or do not feel comfortable following the instructions, contact your Daniel representative for clarification or assistance. Install this product as specified in the INSTALLATION section of this manual per applicable local and national codes. Follow all instructions during the installation, operation, and maintenance of this product. Connect the product to the appropriate pressure and electrical sources when and where applicable. Ensure that all connections to pressure and electrical sources are secure prior to and during equipment operation. Use only replacement parts specified by Daniel. Unauthorized parts and procedures can affect this product's performance, safety, and invalidate the warranty. Look-a-like substitutions may result in deadly fire, explosion, release of toxic substances or improper operation. Save this instruction manual for future reference.

Notice THE CONTENTS OF THIS PUBLICATION ARE PRESENTED FOR INFORMATIONAL PURPOSES ONLY, AND WHILE EVERY EFFORT HAS BEEN MADE TO ENSURE THEIR ACCURACY, THEY ARE NOT TO BE CONSTRUED AS WARRANTIES OR GUARANTEES, EXPRESSED OR IMPLIED, REGARDING THE PRODUCTS OR SERVICES DESCRIBED HEREIN OR THEIR USE OR APPLICABILITY. ALL SALES ARE GOVERNED BY DANIEL'S TERMS AND CONDITIONS, WHICH ARE AVAILABLE UPON REQUEST. WE RESERVE THE RIGHT TO MODIFY OR IMPROVE THE DESIGNS OR SPECIFICATIONS OF SUCH PRODUCTS AT ANY TIME. DANIEL DOES NOT ASSUME RESPONSIBILITY FOR THE SELECTION, USE OR MAINTENANCE OF ANY PRODUCT. RESPONSIBILITY FOR PROPER SELECTION, USE AND MAINTENANCE OF ANY DANIEL PRODUCT REMAINS SOLELY WITH THE PURCHASER AND END-USER. TO THE BEST OF DANIEL'S KNOWLEDGE THE INFORMATION HEREIN IS COMPLETE AND ACCURATE. DANIEL MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABIL- ITY AND FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT TO THIS MANUAL AND, IN NO EVENT, SHALL DANIEL BE LIABLE FOR ANY INCIDENTAL, PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED TO, LOSS OF PRODUCTION, LOSS OF PROFITS, LOSS OF REVENUE OR USE AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL, FUEL AND POWER, AND CLAIMS OF THIRD PARTIES. PRODUCT NAMES USED HEREIN ARE FOR MANUFACTURER OR SUPPLIER IDENTIFICATION ONLY AND MAY BE TRADEMARKS/REGISTERED TRADEMARKS OF THESE COMPANIES

Warranty and Limitations 1. LIMITED WARRANTY: Subject to the limitations contained in Section 2 herein, Daniel Measurement & Control, Inc. ( Daniel ) warrants that the licensed firmware embodied in the Goods will execute the programming instructions provided by Daniel, and that the Goods manufactured by Daniel will be free from defects in materials or workmanship under normal use and care and Services will be performed by trained personnel using proper equipment and instrumentation for the particular Service provided. The foregoing warranties will apply until the expiration of the applicable warranty period. Goods are warranted for twelve (12) months from the date of initial installation or eighteen (18) months from the date of shipment by Daniel, whichever period expires first. Consumables and Services are warranted for a period of 90 days from the date of shipment or completion of the Services. Products purchased by Daniel from a third party for resale to Buyer ("Resale Products ) shall carry only the warranty extended by the original manufacturer. Buyer agrees that Daniel has no liability for Resale Products beyond making a reasonable commercial effort to arrange for procurement and shipping of the Resale Products. If Buyer discovers any warranty defects and notifies Daniel thereof in writing during the applicable warranty period, Daniel shall, at its option, correct any errors that are found by Daniel in the firmware or Services or repair or replace F.O.B. point of manufacture that portion of the Goods or firmware found by Daniel to be defective, or refund the purchase price of the defective portion of the Goods/Services. All replacements or repairs necessitated by inadequate maintenance, normal wear and usage, unsuitable power sources or environmental conditions, accident, misuse, improper installation, modification, repair, use of unauthorized replacement parts, storage or handling, or any other cause not the fault of Daniel are not covered by this limited warranty, and shall be at Buyer's expense. Daniel shall not be obligated to pay any costs or charges incurred by Buyer or any other party except as may be agreed upon in writing in advance by Daniel. All costs of dismantling, reinstallation and freight and the time and expenses of Daniel's personnel and representatives for site travel and diagnosis under this warranty clause shall be borne by Buyer unless accepted in writing by Daniel. Goods repaired and parts replaced by Daniel during the warranty period shall be in warranty for the remainder of the original warranty period or ninety (90) days, whichever is longer. This limited warranty is the only warranty made by Daniel and can be amended only in a writing signed by Daniel. THE WARRANTIES AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE. THERE ARE NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, AS TO MERCHANTABILITY, FITNESS FOR PARTICULAR PURPOSE OR ANY OTHER MATTER WITH RESPECT TO ANY OF THE GOODS OR SERVICES. Buyer acknowledges and agrees that corrosion or erosion of materials is not covered by this warranty. 2. LIMITATION OF REMEDY AND LIABILITY: DANIEL SHALL NOT BE LIABLE FOR DAMAGES CAUSED BY DELAY IN PERFORMANCE. THE REMEDIES OF BUYER SET FORTH IN THIS AGREEMENT ARE EXCLUSIVE. IN NO EVENT, REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION (WHETHER BASED IN CONTRACT, INFRINGEMENT, NEGLIGENCE, STRICT LIABILITY, OTHER TORT OR OTHERWISE), SHALL DANIEL'S LIABILITY TO BUYER AND/OR ITS CUSTOMERS EXCEED THE PRICE TO BUYER OF THE SPECIFIC GOODS MANUFACTURED OR SERVICES PROVIDED BY DANIEL GIVING RISE TO THE CLAIM OR CAUSE OF ACTION. BUYER AGREES THAT IN NO EVENT SHALL DANIEL'S LIABILITY TO BUYER AND/OR ITS CUSTOMERS EXTEND TO INCLUDE INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES. THE TERM CONSEQUENTIAL DAMAGES SHALL INCLUDE, BUT NOT BE LIMITED TO, LOSS OF ANTICIPATED PROFITS, REVENUE OR USE AND COSTS INCURRED INCLUDING WITHOUT LIMITATION FOR CAPITAL, FUEL AND POWER, AND CLAIMS OF BUYER'S CUSTOMERS.

Gas and Liquid Ultrasonic Flow Meters PED Installation and Operation Manual Table of Contents 3-9000-745 Rev F August 2017 Contents Preface Section 1: Introduction... 1 1.1 Purpose... 1 Section 2: Scope... 3 2.1 Document scope... 3 Section 3: Installation... 5 3.1 Meter installation... 5 Table of Contents 1

Table of Contents August 2017 Gas and Liquid Ultrasonic Flow Meters PED Installation and Operation Manual 3-9000-745 Rev F 2 Table of Contents

Gas and Liquid Ultrasonic Flow Meters PED Installation and Operation Manual List of TablesList of Tables 3-9000-745 Rev F August 2017 List of Tables Table 3-1Relevant parts of the Essential Safety Requirements (ESR)... 6 List of Tables iii

List of TablesList of Tables August 2017 Gas and Liquid Ultrasonic Flow Meters PED Installation and Operation Manual 3-9000-745 Rev F iv List of Tables

Gas and Liquid Ultrasonic Flow Meter PED Installation and Operation Manual Section 1: Introduction 3-9000-745 Rev F August 2017 Section 1: 10 1.1 Purpose Introduction This document shall identify specific installation and operation instructions necessary to ensure compliance with the Essential Safety Requirements (ESR) of the European Economic Area Pressure Equipment Directive (PED) 97/23/EC and the UK Pressure Equipment Regulations 1999 (SI 1999/2001). Purpose 1

Section 1: Introduction August 2017 Gas and Liquid Ultrasonic Flow Meter PED Installation and Operation Manual 3-9000-745 Rev F 2 Purpose

Gas and Liquid Ultrasonic Flow Meter PED Installation and Operation Manual Section 2: Scope 3-9000-745 Rev F August 2017 Section 2: 21 Scope 2.1 Document scope This document applies to all Daniel Ultrasonic Flow Meters designed by Daniel Measurement and Control, Inc. (Daniel) of Houston, Texas, USA, and manufactured by Daniel or an authorized agent. Document scope 3

Section 2: Scope August 2017 Gas and Liquid Ultrasonic Flow Meter PED Installation and Operation Manual 3-9000-745 Rev F 4 Document scope

Gas and Liquid Ultrasonic Flow Meter PED Installation and Operation Manual Section 3: Installation 3-9000-745 Rev F August 2017 Section 3: Installation 31 3.1 Meter installation Daniel Ultrasonic Flow Meters are supplied as components to be installed in the end user's piping system. It is the responsibility of the end user of the equipment to ensure compliance with the Essential Safety Requirements of the Directive and Regulations quoted in Section 1.1 of this document. Relevant parts of the directive ESR are listed below. Meter installation 5

Section 3: Installation August 2017 Gas and Liquid Ultrasonic Flow Meter PED Installation and Operation Manual 3-9000-745 Rev F Table 3-1 Relevant parts of the Essential Safety Requirements (ESR) PED ESR reference ESR requirement Compliance requirement 2.3 Provisions to ensure safe handling and operation: The method of operation specified for pressure equipment must be such as to preclude any reasonably foreseen risk in the operation of the equipment. Particular attention must be paid, where appropriate, to the following. Closures and openings: Devices to prevent physical access while pressure or a vacuum exists. Surface temperature Decomposition of unstable fluids Gas Ultrasonic Flow Meters: During removal and replacement of transducers the end user shall ensure that the meter has been properly isolated and the internal pressure has been safely vented. If changing the transducers under line pressure by means of the Daniel supplied extractor tool; the instructions for use given in the manual supplied with each extractor tool must be strictly complied with. Liquid Ultrasonic Flow Meters: Refer to the Daniel Ultrasonic Flow Meter Installation, Maintenance and Troubleshooting manuals for detailed procedures. Daniel Liquid Ultrasonic Flow Meters are supplied with transducers which are extractable while the line is pressurized. The end user shall ensure that the meters are installed in a properly designed system with access limitation in place if required. It is the responsibility of the end user to assess the expected surface temperature in service, and if necessary, take the necessary precautions to avoid personnel coming into contact with the equipment. It is not envisaged that, for the designed service, the equipment shall come into contact with unstable fluids. However, the end user should assess the risk and take any steps considered necessary. 6 Meter installation

Gas and Liquid Ultrasonic Flow Meter PED Installation and Operation Manual Section 3: Installation 3-9000-745 Rev F August 2017 PED ESR reference ESR requirement Compliance requirement 2.4 Means of examination: Pressure equipment must be designed and constructed so that all necessary examinations to ensure safety can be carried out. 2.5 Means of draining and venting: To avoid harmful effects such as water hammer, vacuum collapse, corrosion and uncontrolled chemical reactions. Daniel Ultrasonic Flow Meters are designed so that all critical parts can be examined without the need to remove the unit from service. The end user should refer to the operations and maintenance instructions supplied with each meter. It is not considered that the process medium for which the equipment is designed will give rise to severe corrosion/erosion problems. It is the end user's responsibility to monitor any change in the process medium that may cause concern. It is the responsibility of the end user to ensure that the equipment is installed in a well-designed piping system to avoid such hazards. 2.6 Corrosion or other chemical attack: It is not expected that the process medium for which the meters are designed will give rise to severe corrosion problems. It is the end user's responsibility to monitor any change in the process medium that may cause concern. 2.7 Wear: It is not expected that the use of the meter for fluid measurement will give rise to any abnormal wear problems. It is the responsibility of the end user to install any necessary filtration upstream of the meter to maintain the condition of the process medium. 2.10 Protection against exceeding the allowable limits of the pressure equipment: The Daniel Ultrasonic Flow Meters must be installed in a well-designed piping system with adequate protection against excessive pressure. 2.12 External fire: The Daniel Ultrasonic Flow Meters have no special accessories for fire damage limitation. It is the responsibility of the end user to provide adequate fire-fighting facilities on-site. 7.3 Pressure limiting devices, particularly for pressure vessels: The Daniel Ultrasonic Flow Meters are not pressure vessels and have no integral pressure limiting devices. It is the responsibility of the end user to ensure that the meters are installed in a well-designed system so that momentary pressure surges are limited to under 10% of the meters maximum allowable pressure. Meter installation 7

Section 3: Installation August 2017 Gas and Liquid Ultrasonic Flow Meter PED Installation and Operation Manual 3-9000-745 Rev F 8 Meter installation

P/N 3-9000-745 Rev F 2017 Emerson Process Management Daniel Measurement and Control, Inc. North America / Latin America: Headquarters USA - Houston, Texas T+1.713.467.6000 USA Toll Free 1.888.FLOW.001 www.emersonprocess.com/daniel Europe: Stirling, Scotland, UK T + 44.1786.433400 Middle East, Africa: Dubai, UAE T +971.4.811.8100 Asia Pacific: Singapore T +65.6777.8211 2017 Daniel Measurement and Control, Inc., All rights reserved. Unauthorized duplication in whole or in parts is prohibited. Printed in the USA. Daniel Measurement and Control, Inc. ( Daniel ) is an Emerson Process Management business unit. The Daniel name and logo are trademarks of Daniel Industries. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other trademarks are property of their respective companies.