Effect of Wind and Structural Parameters on Wind-Induced Acceleration of RC Building

Similar documents
Benchmark Buildings for an International HFBB Comparison

Calculation of Wind Loads on Structures according to ASCE 7-10

SEISMIC ANALYSIS OF BUILDING USING TWO TYPES OF PASSIVE ENERGY DISSIPATION DEVICES

Comparative study of wind tunnel test results to international and Egyptian design codes

Wind Tunnel Applications for Buildings

Effect of Wind Load on High Rise Buildings Considering Aspect Ratio

Dynamic optimization for the wind-induced response of a tall building

APPENDIX A - Seismic Terms, Tables and Figures:

Wind Tunnel Applications for Buildings

Flood Risk Analysis of Bridge A Case Study

WIND LOADS ON BUILDINGS MWFRS (ENVELOPE PROCEDURE)

Investigation of PTMD System Affected by Parkfield Near-Field Earthquake

Analysis of G+7 Multistoried Building for Various Locations of Shear Wall Considering the Effect of Torsion Using Response Spectrum Method

Seismic Analysis of Structure by Introducing Weak Story on Top as Tuned Mass Damper

Full Paper Proc. of Int. Conf. on Advances in Civil Engineering 2012

Comparison Between Wind And Seismic Load On Different Types Of Structures

SEISMIC PERFORMANCE OF SUPER TALL BUILDINGS

RISK-BASED DECISION ANALYSIS FOR BUILDING SERVICEABILITY

Improved Limiting Criteria for Deflection in Multi-Story Buildings Subjected to Aerodynamic Load

An Experimental Investigation on Dynamic Response Control of Structures using Tuned Liquid Column Damper

Vibrational Response of Structures Exposed to Human-induced Loads

Shaking Table Model Test of a HWS Tall Building

Vibration Control by Tuned Liquid Dampers

SSRG International Journal of Civil Engineering ( SSRG IJCE ) Volume 4 Issue 6 June 2017

DYNAMIC WIND LOADING OF H-SHAPED TALL BUILDINGS

R. J. McNamara, S.E.

Torsional and Seismic Behavior of Shear Wall Dominant Flat Plate Buildings

Computational Techniques in Wind Response of Tall Buildings

Prediction of Wind Loads on Tall Buildings: Development and Applications of an Aerodynamic Database

The Effects of Building Parameters on the Modal Displacement Shapes of Tall Buildings

Earthquake Analysis of Tall Building with Tuned Mass Damper.

ctbuh.org/papers New CTBUH Monograph on Building Motion, Perception and Mitigation Title:

Chapter 13 SEISMICALLY ISOLATED STRUCTURE DESIGN REQUIREMENTS

Comparative Study on Dynamic Analysis of Irregular Building with Shear Walls

Effects of Neighboring Building on Wind Loads

Performance-Based Seismic Evaluation of Wind-Impacted Tall Buildings

ANALYSIS OF WIND & EARTHQUAKE LOAD FOR DIFFERENT SHAPES OF HIGH RISE BUILDING

WIND TUNNEL STUDIES AND THEIR VALIDATIONS WITH FIELD MEASUREMENTS FOR A SUPER-TALL BUILDING

Analysis of Lateral Loads for a Framed Model with Tuned Liquid Damper

Seismic Damage-Resistant System for Multi-Storey Modular Light Steel Framed Buildings

OPTIMUM POSITION OF OUTRIGGER WITH BELT TRUSS IN HIGH-RISE BUILDING UNDER HORIZONTAL LOADING

ANSI/SPRI Wind Design Standard Practice for Roofing Assemblies

DAMPING IN TALL BUILDINGS AND TOWERS. This tutorial is a follow-up to Reference 1.

Some Structural Design Issues of the 14-Storey Timber Framed Building Treet in Norway

Technical Data Sheet

ISSN: ISO 9001:2008 Certified International Journal of Engineering Science and Innovative Technology (IJESIT) Volume 2, Issue 4, July 2013

AERODYNAMIC RESPONSE OF LONG SPAN CABLE STAYED CONCRETE BRIDGE

Parametric Analysis on Buildings with Connecting Corridors Afiya V N


Fluid Viscous Dampers to reduce Wind-induced Vibrations in Tall Buildings

Tests and Analysis on Vertical Vibration of Long-Span Prestressed Concrete Floor Sysstem Abstract: Keywords: INTRODUCTION Corresponding Author:

A new approach for the Seismic Isolation Methods for Ancient Statues Displayed in Base Isolated Museums

EFFECT OF FLUID VISCOUS DAMPERS IN MULTI-STOREYED BUILDINGS

Seismic analysis of vertically geometric irregular structures

Base isolation. Philippe Bisch IOSIS, EGIS group. EUROCODE 8 Background and Applications

Introduction to Substation Design TADP 542

PROPOSED CHANGE TO THE 2012 BUILDING CODE O. REG. 332/12 AS AMENDED

SET PROJECT STRUCTURAL ANALYSIS OF A TROUGH MODULE STRUCTURE, IN OPERATION AND EMERGENCY Luca Massidda

SEISMIC PERFORMANCE OF HIGH-RISE BUILDING

Megacities Building Sway Considerations in Elevators Design for Mega Tall Buildings

Effect of Change in Shear Wall Location with Uniform and Varying Thickness in High Rise Building

THE EFFECT OF BEHAVIOUR FACTOR ON THE SEISMIC PERFORMANCE OF LOW-RISE AND HIGH-RISE RC BUILDINGS

VIBRATIONS INDUCED BY HUMAN ACTIVITIES IN COMPOSITE STEEL FLOOR DECKS. CASE STUDY

Case Study: Challenges of a Single-layer Reticulated Dome

Optimum Position of Outrigger System for Tall Vertical Irregularity Structures

Structures of tall buildings

EARTHQUAKE RESPONSE ANALYSIS OF MID-STORY BUILDINGS ISOLATED WITH VARIOUS SEISMIC ISOLATION TECHNIQUES

OPTIMUM DAMPING IN ISOLATION SYSTEM

Optimization of Multistory Building with Multi- Outrigger System and Belts Truss

Optimization of Wind Loads Affecting Skyscrapers using ANSYS

Concept of Earthquake Resistant Design

Effect of Building Height on Torsional Response of Lead Rubber Bearing Base Isolated Structures-A Study

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 5, No 3, 2015

Vibration control of a building model with base isolation

Floor spectra for analysis of acceleration-sensitive equipment in buildings

Effect of plastic hinge, soil nonlinearity and uplift on earthquake energy in structures

Effect of Base Isolation in Multi-Storeyed RC Building

Optimum Design of Active and Passive Cable Stayed Footbridges

VIBRATION EVALUATION OF FLOOR SYSTEMS FOR FOOTFALL USING ADAPT-FLOOR PRO

EFFECT OF SOFT STOREY LEVEL VARIATION ON TORSIONAL ROTATION OF LEAD RUBBER BASE ISOLATED STRUCTURE

IJSRD - International Journal for Scientific Research & Development Vol. 5, Issue 04, 2017 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 07, 2016 ISSN (online):

Seismic behavior of concrete structures equipped with ADAS devices

SEISMIC BEHAVIOR OF MULTI-STORY STRUCTURE WITH DIFFERENT TYPES OF SLABS

EARTHQUAKE LATERAL FORCE ANALYSIS. Dr. Jagadish. G. Kori Professor & Head Civil Engineering Department Govt. Engineering College, Haveri

Improvements of FE Models for Predicting Natural Frequencies of Building Structures Based Upon Field Measurement Data

Earthquake Analysis of Multi Storied Residential Building - A Case Study

Part III Special Topics of Bridges

EQUIVALENT UNIFORM DAMPING RATIOS for Irregular in Height Concrete / Steel Structural systems

WIND LOADS ON BALUSTRADES. Antonios W. Rofail a, Christian Mans a

Seismic Behavior of Concrete Retaining Wall with Shear Key, Considering Soil-Structure Interaction

SEISMIC RESPONSE ANALYSIS OF VERTICALLY IRREGULAR RC BUILDINGS USING LAMINATED RUBBER BEARING

EFFECTS OF STRONG-MOTION DURATION ON THE RESPONSE OF REINFORCED CONCRETE FRAME BUILDINGS ABSTRACT

boundary layer wind flow. Measured wind pressures were expanded from limited measurement points to all the structural nodes using the orthonormal coor

ISSN: International Journal Of Core Engineering & Management (IJCEM) Volume 3, Issue 4, July 2016

Behaviour of an Elevated Water Tank for Different Staging Patterns and Different Staging Heights

Integrated Performance Based Design of Tall Buildings for Wind and Earthquakes

OPTIMUM INSTALLATION OF VISCOUS LIQUID DAMPERS IN HIGH-RISE BUILDINGS

SEISMIC RESPONSE OF MULTISTOREYED STEEL FRAME WITH VISCOUS FLUID SCISSOR JACK DAMPERS

Performance Based Seismic Design of Reinforced Concrete Building

Transcription:

ISBN 978-93-84468-11-8 Proceedings of International Conference on Architecture And Civil Engineering (ICAACE'14) Dubai, December 5-6, 14, pp. 135-149 Effect of Wind and Structural Parameters on Wind-Induced Acceleration of RC Building Jumana Al Balushi 1 (Corresponding Author), and A. D. John 1, Caledonian College of Engineering, Muscat, Oman Abstract: The purpose of this study is to evaluate the performance of tall building on human comfort on windinduced acceleration using ASCE7-1 method. Along-wind accelerations for three building models (4, 3 and storey) for various categories of surface roughness and structural damping were analyzed. The natural frequencies of all the buildings were determined by carrying out numerical analysis. The results of the alongwind acceleration by ASCE7-1 method signify that the buildings with low structural damping increase their acceleration levels under even moderate wind speeds. Further, analysis results of different categories of surface roughness show significant change in the pattern between along-wind acceleration and structural damping. Keywords: along-wind acceleration, terrain categories, structural damping. 1. Introduction Wind-induced vibrations in tall buildings for human comforts are usually evaluated by the along-wind or across-wind acceleration. High-rise buildings are likely to be light in weight and flexible and therefore, more significant to wind dynamic motion problems. Different terrains or surface roughness categories may affect wind dynamic motion of high rise building. Closer to the surface the wind speed is affected by frictional drag of the air stream over the terrain. There is a boundary layer within which the wind speed varies from almost zero at the surface to the gradient wind speed at a height known as the gradient height. When considering the response of a tall building to wind dynamic loads, wind induced acceleration must be considered. Also, it is necessary to evaluate the buildings dynamic behavior related to wind-induced accelerations at top storey to assess occupants comfort [1]. These arise due to buffeting effects of wind caused by turbulence. [] Discussed on comfort criteria: human response to building motion, authors have discussed that their is no international standard for comfort criteria in tall building design. However, considerable research has been carried out into the important physiological and psychological parameters that affect human perception to motion and vibration encountered in tall buildings. These parameters include accelerations for both the translational and rotational motions to which the occupant is subjected. Guidelines on general human perception levels are given in Table 1. [3] Studied on acceleration indexes for occupant comfort in tall building using rms and peak values of acceleration. Human perception of vibration and tolerance of wind-induced tall building vibration are essentially a subjective assessment [4]. Hence, there is currently no single internationally accepted occupant comfort serviceability criteria which set a design standard for satisfactory levels of wind-induced vibration in tall buildings. It is evident from the literature, the most important criterion for verifying comfort of building s occupants is the peak acceleration they are likely to experience. It is thus important to estimate the probable maximum accelerations in along-wind directions. In this paper, first, numerical analysis had been carried out to find natural frequencies of forty, thirty and twenty storey buildings of different height. Then, along-wind accelerations were computed for all buildings using ASCE7-1 [5] method. Different categories of surface roughness and structural damping of the building were used to calculate along-wind accelerations. http://dx.doi.org/1.17758/ur.u11434 135

TABLE I: Human sensitivity levels against acceleration []. Level Acceleration (m/sec ) Effect 1 <.5 Humans cannot perceive motion..5 -.1 Sensitive people can perceive motion. Hanging objects may move slightly. 3.1 -.5 Level of motion may affect desk work. Long term exposure may produce motion sickness. 4.5 -.4 Desk work becomes difficult or almost impossible. 5.4 -.5 Difficult to walk naturally and standing people may lose balance. 6.5 -.6 Unable to walk naturally. 7.6 -.7 People cannot tolerate motion or walk. 8 >.85 Objects begin to fall.. Gust factor For flexible or dynamically sensitive buildings ASCE7-1 [5] recommends gust effect factor (G f ). Gust effect factor depends on basic wind speed (V), exposure category B, C, or D, building natural frequency and building damping. ASCE7-1 defines a rigid building as When buildings height exceeds four times the least horizontal dimension or when the natural frequency is less than 1 Hz, the natural frequency for it should be investigated. The G f for Main Wind Force Resisting System (MWFRS) of flexible buildings and other structures can be obtained by Eq. (1) [5]. 11.7I gqq g z RR G f.95 11.7gvI z where g Q and gv shall be taken as 3.4 g Q = peak factor for background response g R = peak factor for resonance response g v = peak factor for wind response Q = background response factor R = resonant response factor I z = intensity of turbulence 3. Along-wind displacement and acceleration [5] ASCE7-1 recommends a method for calculating along-wind displacement and peak acceleration. The maximum along-wind displacement as a function of height above the ground surface is given by Eq. (). ^ ( BhC fz Vz X max( m1 (n 1) f KG () where ϕ ( is the fundamental model shape = (z/h)ξ, ρ is the air density, B = horizontal dimension of building measured normal to wind direction, h is height of building, C fx is the mean along-wind force coefficient, V z is 3- second gust speed at height z, n 1 is natural frequency at first mode, m 1 = modal mass. Modal mass can be calculated by Eq. (3). h where μ( = mass per unit height. ( ( dz (3) 1.65 k (4) 1 The rms along-wind acceleration σ ẍ( as a function of height above the ground surface is given in Eq. (5). (1) http://dx.doi.org/1.17758/ur.u11434 136

.85 zbhc fxvz I zkr (5) x( m1 where V z is the mean hourly wind speed at height z, ξ is the mode exponent. The maximum along-wind acceleration as a function of height above the ground surface is given in Eq. (6). g max ( x x X x g ( (6).577 In( nt 1 ) (7) In( nt) 1 where T is the length of time over which the acceleration is computed, usually taken to be 36 seconds to represent 1 hour. 4. Surface Roughness Categories According to ASCE7-1 [5], ground surface roughness for the purpose of assigning an exposure category can be defined as follows. Surface Roughness B: Urban and suburban areas or other terrain with numerous closely spaced obstructions having the size of single-family dwelling or larger. Surface Roughness C: Open terrain with scattered obstructions having heights generally less than 3 ft (9.1 m). This category includes flat open country and grasslands. Surface Roughness D: Flat, unobstructed areas and water surfaces. This category includes smooth mud flats, salt flats, and unbroken ice. For a site located in the transition zone between exposure categories, the category resulting in the largest wind forces shall be used. 5. Building configuration Fig 1: Rectangular prism shape buildings (4, 3, and storey) Basic rectangular prism shape buildings were chosen for the present study. To calculate natural frequencies of forty, thirty and twenty storey reinforced concrete buildings numerical studies were performed. The plan dimension of the building were: width W = 36 m and length L = m. whereas, height of buildings are 143.5 m, 18.5 m and 73.5 m for 4, 3 and storey buildings respectively. Rectangular prism shape buildings are shown in Figure 1. Natural frequencies and density for forty, thirty and twenty storey building are shown in Table. TABLE II: Building configurations selected for present study Natural Frequency Building Storey Height (m) x-direction z-direction Density (kn/m 3 ) A 4 143.5.147.1 4.3 B 3 18.5.16.185 4.3 C 73.5.333.89 4.3 6. Results and discussion Along-wind acceleration for forty, thirty and twenty storey reinforced concrete buildings were computed using ASCE7-1 method. Natural frequencies and densities of buildings were determined by numerical analysis http://dx.doi.org/1.17758/ur.u11434 137

and used for the calculation of along-wind acceleration. Analyses were carried out for varying structural damping (.1 to.7) and different categories of wind (B, C and D). Results for along-wind acceleration are shown in Figure and Figure 3 for wind velocities 177 km/hr and 8.5 km/hr respectively. From the results it is evident that variation of along-wind acceleration is not linear for varying values of structural damping as shown in Figure and 3. Minimum values of acceleration found at maximum structural damping and this values increased by.65 times when damping is minimum. Category B Category C Category D.6 4 storey building.5.4.3..1.6.5.4.3..1 3 storey building.6.5.4.3..1 storey building Fig : Along-wind acceleration of RC building for different structural damping and categories of surface roughness at wind velocity of 17 km/hr Category B Category C Category D.6.5.4.3..1. 4 storey building.1.8.6.4.. 3 storey building.1 storey building.8.6.4.. Fig 3: Along-wind acceleration of RC building for different structural damping and categories of surface roughness at wind velocity of 8.46 km/hr http://dx.doi.org/1.17758/ur.u11434 138

Surface roughness categories show significant change in acceleration values for all the buildings particularly when wind velocity is low. Table 3 shows percentage change in acceleration values for surface roughness category B and C compared to category D where maximum acceleration found to be maximum. Acceleration values have been shown in Table 3 for two different velocities of wind. TABLE III. Percentage change in along-wind acceleration Wind velocity Building storey Percentage change in along-wind acceleration for different surface roughness categories B and C compared to D 17 km/hr 8.46 km/hr B 4.33%.34% 3 3.84% 11.3% 8.31% 3.8% 4.8% 4.69% 3 1.51% 15.7% 5.81% 8.3% Further, from Table 3 it is observed that percentage change in along-wind acceleration values are maximum for twenty storey building for different categories of surface roughness compared to acceleration values for 3 and 4 storey building. 7. Conclusion Along-wind acceleration for forty, thirty and twenty storey buildings was evaluated using ASCE7-1 method. Surface roughness categories (B, C and D) and structural damping values between.1 and.7 were considered. It is found that variation of acceleration values for varying damping and different surface roughness categories is not linear. Also, it is found that, although magnitude of along wind acceleration is less for twenty storey building, it has maximum percentage change in the acceleration values for different surface roughness categories compared to thirty and forth storey buildings. 8. References [1] B. S. Taranath, Reinforced concrete design of tall buildings, CRC Press, Taylor & Francis Group, Boca Raton, FL, USA, 1. [] P. Mendis, T. Ngo, N. Haritos, A. Hira, Wind loading on tall buildings, Electronic Journal of Structural Engineering, EJSE Special Issue: Loading on Structures, 7, pp 41-54. [3] D, Boggs, Acceleration indexes for human comfort in tall buildings - peak or rms? In: CTBUH Monograph Chapter 13: Motion Perception Tolerance and Mitigation, 1997. [4] K. C. S. Kwok, P. A. Hitchcock, M. D. Burton, Perception of vibration and occupant comfort in wind-excited tall buildings, Journal of Wind Engineering and Industrial Aerodynamics, vol. 97, pp 368 38, 9. http://dx.doi.org/1.116/j.jweia.9.5.6 [5] ASCE7-1, Minimum design loads for buildings and other structures, American Society of Civil Engineers, Reston, VA, USA, 1. C http://dx.doi.org/1.17758/ur.u11434 139