PROPYLUX HS rods are exclusively produced by Westlake Plastics.

Similar documents
High Purity Plastics. Properties: PTFE filled lower coefficient of friction good electrical isolating properties FDA conformity

durable+ versatile ultem hu1004 resin A high performance resin blend for multiple sterilization environments

Plastics for Orthotics & Prosthetics

FDM Material Properties

Required Biocompatibility Training and Toxicology Profiles for Evaluation of Medical Devices May 1, 1995 (G95-1)

The clear choice for renal device applications.

Biocompatibility Results

FORMLABS WHITE PAPER: A Guide to Post-Curing Formlabs Resins. March 2018 formlabs.com

Required Biocompatibility Training and Toxicology Profiles for Evaluation of Medical Devices

High-Performance Plastics for. Healthcare SPECIALTY

FORMLABS WHITE PAPER: A Guide to Post-Curing Formlabs Resins. March 2018 formlabs.com

RPU 60. RPU 60 is a tough, abrasion-resistant material that is a good choice for parts that require rigidity, strength, and durability.

Directives 90/385/EEC and 93/42/EEC MEDICAL DEVICES. Guidance document for the presentation of biological evaluation

Resistance to Prolonged Hot Water Exposure

Liquidmetal Alloys in Minimally Invasive Medical Devices

SIL CLASS VI SUPPORTED HIGH CONSISTENCY SILICONE ELASTOMER

SOLEIL A2: A 13% Cr high strength martensitic stainless steel (410 grade) C F

Ultraform (POM) AT Product Range

Evonik Corporation. High Performance Polymers for Medical Device Applications. Suneel Bandi, PhD. SPE draft, SPE ANTEC Anaheim 2017 / 1794

Focus on: FEP. Fluoropolymers. FEP in the fluoropolymer family.

Stainless Steel (17/4PH&630) Bar

Helping you shape what s next

Materials Data Sheet. Photopolymer Resin for Form 1+ and Form 2

Makrolon 2558, 2658, 2808 and 2858

TECHNYL A 218 V30 BLACK 34NG

CarbonResin EPX 82 DOC # REV A TECHNICAL DATA SHEET, LAST UPDATED 05/02/2018 EPX 82

Engineered Polymers (Semi-crystalline)

Beyond 85 C: Thermal Aging Impact on Optical Fiber with Corning CPC Coatings

Parker TexMed Heat Shrink. Quick Reference Guide. aerospace climate control electromechanical filtration

Seals On Demand engineered, machined, delivered.

Medical Semiconductor Pharmaceutical / Food Handling Aerospace/Defense industrial : medical Corporate Location Chemical Processing West Coast Office

VERSAFIT V2 AND V4 TUBING Polyolefin, Flexible, Heat-Shrinkable, Flame-Retardant

Autoclave Sterilizable Biocompatible Ductile E-beam Sterilizable

Prepared by: Polyamide 12 Suppliers (Evonik-Degussa and UBE Industries)

Risk Management of Biological Evaluation What s the Future for ISO 10993?

Texin RxT65D. Characterization

We do not sell adhesives. We use the adhesives below to construct products for our customers.

ISO : A Risked Based Approach to Biological Safety

Texin RxT70A. Characterization

FDM - FUSED DEPOSITION MODELING

Material HDT Continuous Use Temp. Radal (Polyphenylsulfone) 400 F 300 F

ABS-M30 PRODUCTION-GRADE THERMOPLASTIC FOR FDM 3D PRINTERS

Vycom s Corrtec family of chemical and corrosion resistant materials offers many polymer options including PVC (Types I and II), CPVC, HDPE, PP, and

Riteflex thermoplastic polyester elastomer Short Term Properties Brochure Riteflex

Stainless Steel (17/4PH&630) Bar

Material Selection Guide

TECHNYL A 218 V35 BLACK 21N

Ultrason E, S, P (PESU, PSU, PPSU) Product Range

Commercial: Active Africa & Middle East Asia Pacific Glass\Mineral, 65% Filler by Weight Heat Stabilizer

Stainless Steel Bar

Palight. Flat Foamed PVC Sheet. Tel: +44 (0) Fax: +44 (0)

High Performance ABS Products for Medical Applications

Designing an effective cleaning procedure for medical devices through laboratory studies

Model EN Optical Encoder Series Material Change

ENGINEERING MATERIAL 100

Shinn Thon UK Ltd 1 st Floor, 223 Dalton Road, Barrow in Furness, Cumbria. LA14 1PQ Tel: Fax:

Redefining the balance between processibility and chemical resistance. A new-generation copolyester

KESTAMID. Cast Polyamide. An engineering plastic replacing metals. New technology, Advanced Properties

POLYLITE Series Polyester Engineered Marble Resin

Commercial: Active Africa & Middle East Asia Pacific

Materials Library Advanced materials designed to deliver beautiful results. FORMLABS MATERIAL LIBRARY

PSS-3000 Sheet. Technical Design Guide. Revision Written By Date of Release. 01 Chuck Clontz March 23, 2012

Processing Guide CONTENTS

PLAZCAST-LED CAST ACRYLIC (PMMA) SHEETS FOR LED LIGHTING SOLID SHEETS YOUR LOCAL STRATEGIC PARTNER

TECHNYL A 218W V30 BLACK FA

PO Box 1081 Monticello, MN Ph Fax

Stainless Steel (17/4PH&630) Bar

Celcon acetal copolymer Short Term Properties Brochure

Development of a Gel Coat With Improved UV Stability

CLEANING VALIDATION FOOD & BEVERAGE WASTEWATER LABORATORY PHARMACEUTICAL & MEDICAL DEVICE

Engineering Plastics and High Performance Materials

ERTALON Extruded Products

PVDF KYNAR FLEX TM Tubing FDA COMPLIANT UV STABLE LOW TOC PVDF

Amodel AS-1133 HS. polyphthalamide. Technical Data Sheet

DuPont Delrin 100ST NC010

Series K7130 Heavy Wall PVC Transfer Hose. Compound hardness 73 ±3 Shore A. Self-extinguishing. Non-marking, non-toxic and silicone-free.

Call For Your Local Distributor of Nu-Poly Mezzanine Decking

Physical Dry Conditioned Unit Test method

FIBERGLASS REINFORCED PLASTIC (FRP) LAUNDER COVERS

THERMOFIT RNF-100 TUBING Polyolefin, Flexible, Heat-Shrinkable

glass-reinforced nylon resin

UDDEHOLM NIMAX. Nimax is a trade mark registered in the European Union and in the U.S.

Typical Property Values. Property Test Method Unit Value

Ixef Technical Data. polyarylamide

Last Updated: August, / 5

Makrolon. Product range Typical values

UTILIZING THE CLEARWELD TM PROCESS FOR MEDICAL APPLICATIONS

Commercial: Active Africa & Middle East Asia Pacific Glass Fiber, 50% Filler by Weight Flame Retardant. Physical Typical Value Unit Test method

Zytel. DuPont HTN. Letting You Do More for Less. high performance polyamide resins. Solutions in Zytel

SYSTEMS AND MATERIALS OVERVIEW. FDM 3D Printers

Stereolithography Material Properties

STRENGTH+ High Modulus Carbon Fiber Reinforced LNP. High performance compounds for structural healthcare applications

Engineering Plastic for Food Processing and Packaging Equipment

Study Of Mechanical and Physical Properties of Wood Plastic Composite, Polypropylene, Rose, Teak and Neem Wood Sunil C 1 Dr. G. B.

Sterilization of Schweickhardt Instruments

THERMOFIT RNF-150 TUBING Flexible, Heat-Shrinkable, Flame-Retarded Modified Fluoropolymer

Objet Materials. The Power behind your 3D Printer

Product Data Sheet. Eastar Copolyester Key Attributes

PolyJet 3D Printers SYSTEMS AND MATERIALS OVERVIEW THE 3D PRINTING SOLUTIONS COMPANY

SURFACE VEIL CONTINUOUS GLASS ROVING. Color

Transcription:

PROPYLUX HS rods are exclusively produced by Westlake Plastics. Launched in 2004 by Westlake Plastics Europe, PROPYLUX HS has gained wide acceptance by orthopedic device manufacturers in Europe. PROPYLUX HS products deliver the required attributes for orthopedic applications including biocompatibility, chemical resistance and dimensional stability. At a similar price point as POMALUX, PROPYLUX HS offers superior dimensional stability performance when processed through repeated 134 C Prion autoclaving cycles.the material also provides excellent chemical resistance to disinfecting and cleaning solutions and exhibits a very good balance of strength, toughness and ductility. As such, PROPYLUX HS is well suited for use in applications including trial heads and cups for hip implants, knee provisional trials and impactor applications. The PROPYLUX HS product line consists of 15 colors and 13 diameters. All colored materials are made with FDA compliant ingredients and the shaped rods have been tested and comply with key parts of ISO 10993.

Regulatory Compliance Colored PROPYLUX HS rods feature a unique biocompatibility profile that combines testing per color on fabricated parts using GLP protocol. The fabricated parts were soaked in machining lubricant for 72 hours to simulate worst-case conditions and then cleaned. The performance of the cleaning process was assessed by a chemical characterization test (ISO 10993-18). Claiming equivalence to our biocompatibility tests is made easy by accessing our US FDA Master Access File (for the US market only). The polypropylene resin conforms to FDA. 21 CFR 177.1520(c)3.2a as well as USP Class VI Pigments conform to FDA 21 CFR 178.3297 Additives conform to FDA 21 CFR 182.8994, 21 CFR 178.2010 and 21 CFR 178.3400 PROPYLUX HS is FDA Master File listed. Contact Westlake Plastics for access authorization and further information. PROPYLUX HS shaped colored materials have been tested and are compliant with key parts of ISO 10993 as outlined in the tables below. Use of International Standard ISO 10993-1, "Biological evaluation of medical devices Part 1: Evaluation and testing within a risk management process" US FDA Guidance Published in June 16th, 2016 Limited Contact Duration ( 24 hours) Prolonged Contact Duration (> 24 hours to 30 days) Permanent Contact Duration ( 30 days) Surface device in contact with intact skin Surface device in contact with mucosal membrane Surface device in contact with breached or compromised surface External communicating device in contact with blood path, indirect External communicating device in contact with tissue/bone/dentin External communicating device in contact with circulating blood Implant device in contact with tissue/bone ISO 10993 Testing Black Dark Blue Light Blue Brown Neon Green Dark Green Grey Orange Red Yellow White Magenta Aqua Violet Rust Chapter 5 Cytotoxicity Chapter 10 Intracutaneous Irritation Chapter 10 Maximization/Sensitization Chapter 11 Acute Systemic Toxicity Chapter 11 Material-Mediated Pyrogenicity Steam Sterilization PROPYLUX HS can be repeatedly steam sterilized at either 134 C/18 min or 121 C/30 min. Westlake Plastics has successfully tested PROPYLUX HS up to 500 cycles (134 C/18 ) with no major shift in dimensional stability or color fading. Polypropylene shows very low moisture absorption (10 times lower than Acetal POM C per ASTM D570). It is to be noted that PROPYLUX HS will expand during autoclaving cycle and shrink to its original shape as it cools down. Consequently, we advise to perform development testing for instrument handles in which PROPYLUX HS would be constrained on both sides (ie: impactor handle). PROPYLUX HS is very well suited for other devices like trial heads and cups, trial knees and patellas, trial humeral cups or impactor bumpers. Phone : 1.610.459.1000 - Phone : 1.800.999.1700 - Fax : 877.789.0601 - Web : www.westlakeplastics.com - Email : info@westlakeplastics.com

Chemical Resistance Study : simulated worst-case neutralizing process Chemical resistance is a critical characteristic for orthopedic devices which undergo repeated cleaning and disinfection cycles over their lifespan. PROPYLUX HS offers excellent resistance to a wide range of chemicals including acidic and alkaline solutions. To highlight this comparative basis, PROPYLUX HS along with POM C and PPSU were exposed to a worst-case acidic neutralizing process and evaluated for a visible sign of attack. Machined trial heads soaked in phosphoric acid (PH 2.5) for 10 minutes. (Phosphoric acid is commonly used as neutralizing agent) No rinsing Components were dried with hot air for 15 minutes As shown in the photos and summarized in the table below, PROPYLUX HS exhibited excellent chemical resistance and superior performance compared to POM C. This test highlights that Propylux offers an additional factor of safety against strong acids. BEFORE TESTING AFTER TESTING CLOSE UP ON POM C AFTER TESTING PPSU PROPYLUX HS POM C Effects of Passivation Process POM C PPSU PROPYLUX HS : no visible change to exposed surfaces Slight : changes noticeable with the naked eye Discoloration / Mottling Stress Cracking Etching Outgassing Moderate Slight Severe Severe affecting less than 25% of exposed surface Moderate : changes noticeable with the naked eye affecting more than 25% of exposed surface Severe : changes noticeable with the naked eye affecting more than 50% of exposed surface Phone : 1.610.459.1000 - Phone : 1.800.999.1700 - Fax : 877.789.0601 - Web : www.westlakeplastics.com - Email : info@westlakeplastics.com

Dimensional Stability An internal study confirmed the ability of PROPYLUX HS to maintain its excellent dimensional stability at 50 autoclave cycles (tests not run to failure). Trial hip parts (head & cup) were chosen to perform this test with the most critical parameters being evaluated with 3D CMM equipment. In each case PROPYLUX HS shows a far better dimensional stability than POM C and equivalence to PPSU. According to many orthopedic device manufacturers, PROPYLUX HS can withstand over 500 autoclaving cycles. PROPYLUX HS PPSU POM C Diameter (mm) Trial Head - External Sphere Angle ( ) Trial Head - Cone Diameter (mm) Trial Cup - Internal Sphere Diameter (mm) Trial Cup - External Sphere Phone : 1.610.459.1000 - Phone : 1.800.999.1700 - Fax : 877.789.0601 - Web : www.westlakeplastics.com - Email : info@westlakeplastics.com

Laser Engraving All PROPYLUX HS colors are suitable for laser engraving. Machine settings and results will vary depending on the type of laser marking system used. The sample pieces in the picture on the right were marked using a fiber YAG laser system. Best results are obtained using a UV laser. Machining PROPYLUX HS is easily machined into intricate parts with complex designs. We can provide technical advice on the machining of PROPYLUX HS products. Case Study We evaluated the price impact on a knee trial using PROPYLUX HS vs. PPSU. We chose a posterior stabilized, size 5 and thickness 14mm as mid-range item. The stock shape used was a cut off diameter 3 rod in both cases. Prices are based on Westlake Plastics standard price list. Considering a range of 5 sizes and 6 thicknesses (from 10mm to 20mm), launching a production of 20 parts per size in PROPYLUX HS would help save around $ 9,000. Stock shape cost per unit Stock shape cost per unit $ 8.00 $ 20.50 Properties of the Resin Properties of the resin ASTM Method SI Units Imperial Units Physical Characteristics Density D1505 0.90 g/cm 3 0.90 g/cm 3 Water absorption D570 0.025 % 0.025 % Mechanical Characteristics Tensile Strength @ Yield 34.7 MPa 5.04 kpsi Tensile Strength @ Break 27.3 MPa 3.96 kpsi Tensile Elongation @ Yield 4.6 % 4.6 % Tensile Elongation @ Break 20 % - 60 % 20 % - 60 % Tensile Modulus Izod impact (0.50 ) @ Notched Izod impact (0.50 ) @ Un-Notched Hardness (R scale) D256 D256 D785 Thermal Characteristics 20.1 MPa 292 kpsi 0.48 J/cm 1.32 ft-lbs/in No Break No Break 92 92 Heat Deflection Temp at 66 psi D648 150 C 302 F Heat Deflection Temp at 264 psi D648 71 C 160 F Phone : 1.610.459.1000 - Phone : 1.800.999.1700 - Fax : 877.789.0601 - Web : www.westlakeplastics.com - Email : info@westlakeplastics.com

Phone : 1.610.459.1000 - Phone : 1.800.999.1700 - Fax : 877.789.0601 - Web : www.westlakeplastics.com - Email : info@westlakeplastics.com 15 Standard Colors We have developed a range of 15 standard colors to code your instrumentations. If additional colors are needed, let us work with you to develop new colors. We can make it standard or keep it exclusive to you. THIS COLOR COULD BE YOURS! Tell us the shade you need and we will develop it for you. Minimum order quantities apply. Ø 1/2 (12,7mm) Ø 3/4 (19,05mm) Ø 1 (25,40mm) Ø 1 1/4 (31,75 mm) Ø 1 1/2 (38,10 mm) Ø 1 3/4 (44,45 mm) STANDARD DIAMETER RANGE Custom diameters are available upon request. Minimum order quantities would apply. Ø 2 (50,80 mm) Ø 2 1/4 (57,15 mm) Ø 2 1/2 (63,50 mm) Ø 2 3/4 (69,85 mm) Ø 3 (76,20 mm) Ø 3 1/4 (82,55 mm) Ø 3 1/2 (88,90 mm) STANDARD LENGTH : 8ft / 2438mm STANDARD LENGTH : 4ft / 1219mm

ASSISTANCE Westlake can make performance validation easy. When you consider using PROPYLUX HS for a new project or a legacy instrument, our team is at your service to help execute your plan! We understand the biocompatibility profile is important and product validation is crucial. Let us help you through this process : we can help define a protocol, machine prototypes, run multiple autoclaving cycles and perform dimensional evaluation. Case Study & Testimonial PROPYLUX HS was successfully used for the manufacturing of In tech Medical s bumper on a femoral implant holder. While alternative polymers were evaluated, PROPYLUX HS showed the best performance. Its high ductility makes it an excellent option for impactor devices. We recently developed a unique femoral impactor which can be adapted to every OEM s condyle implant geometry by switching out the bumper. This allows us to minimize customizations & provide the market with a turn-key OEM instrument. The bumper is instrumental as it ensures a snug fit with femoral condyle implant while transferring energy required for final positioning of implant in patient s femur. Looking at our needs, Westlake Plastics assisted us in picking the best material for our application, which turned out to be PROPYLUX HS. Indeed, the bumper needed to be strong enough to absorb repeated shocks & we did not want material to lose its properties or become brittle over time. On top of that, the complete biocompatibility profile made validation an easy process! Patrick Khalife Director of R&D Phone: + 1 901 375 1109 1407 Union Avenue #1204 Memphis, TN 38104

We have designed PROPYLUX HS to be the most cost effective solution on the market. It offers excellent dimensional stability, chemical resistance and biocompatibility compliance compared to other medical grade polymers available in the market today and its color range is second to none. Westlake Plastics carries an extensive inventory to serve the orthopedic device market. Please contact us for information on distributors serving your market. 490 West Lenni Road Lenni, PA 19052 U.S.A Phone : 1.610.459.1000 Phone : 1.800.999.1700 Fax : 877.789.0601 Web : www.westlakeplastics.com Email : info@westlakeplastics.com Z.A.C Ravennes les Francs 159, rue de Rotterdam 59910 Bondues FRANCE Phone : (33) 03.20.68.30.35 Fax : (33) 03.20.68.07.05 Web : www.wp-europe.com Email : contact@wp-europe.com FDA registered: #3011274144 21 CFR 820 compliant