TABLE OF CONTENT

Similar documents
TABLE OF CONTENT

TABLE OF CONTENT

TABLE OF CONTENT

MATERIAL STANDARD FOR ELECTRICAL HEAT TRACING ORIGINAL EDITION JAN. 1996

TABLE OF CONTENT

FACILITIES BUILDING STANDARDS

SECTION ULTRASONIC BIOGAS FLOW MEASURING SYSTEM

SECTION Inline ULTRASONIC FLOW METERS

Insulated sheath power cable systems

SECTION GROUNDING

Optimal Control Systems Company Profile

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

Unified control system in power plant TCE approach for implementation in Indian context

Technological Training Programs

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

TECHNOLOGY SOLUTIONS

PIKES PEAK PARKING RESTORATION TABLE OF CONTENTS

SECTION BASIC ELECTRICAL REQUIREMENTS

SECTION ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED

Section 70 Airport Transformer Vault and Vault Equipment (FAA L-109)

City of San Mateo Clean Water Program Programmable Logic Controller (PLC) and Human Machine Interface (HMI) Programming Services

Fuelling progress through Technological Excellence and Domain Expertise... OG Technologies Pte. Ltd.

SPECIAL SPECIFICATION 8772 Border Safety Inspection Facility Transponder Reader System

SPECIAL SPECIFICATION 6683 Border Safety Inspection Facility Transponder Reader System

MATERIAL STANDARDS FOR MISCELLANEOUS ITEMS FIRST EDITION FEBRUARY 2007

Special Specification 6292 Radar Vehicle Detection System for Signalized Intersection Control

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

CITY OF FERNDALE, WA PAGE 1

SPECIAL SPECIFICATION 8783 Border Safety Inspection Facility Transponder Reader System

SECTION Coriolis Mass Flow Meters

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

SECTION EARTHING AND EARTH FAULT PROTECTION

SECTION PART 1 GENERAL

1. Telecommunications mounting elements. 2. Backboards. 3. Telecommunications equipment racks and cabinets. 4. Grounding.

UTECO. Temperature Probes Overview. Temperature Probes for all Industries Level Switches Accessories, Cables & Transmitters

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

UNIFIED FACILITIES GUIDE SPECIFICATIONS. Use for Southeast projects only **************************************************************************

SECTION PARK NON-SEGREGATED BUS SPECIFICATION

SECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE

SECTION UNDERGROUND ELECTRICAL CONSTRUCTION

Design and Milestone Review Report

SERIES 800 / 810 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTER ASSEMBLIES

SECTION CONDUITS AND BOXES PART 1- GENERAL. A. Work covered by this section includes the furnishing and installation of conduits and boxes.

A. Product Data shall be provided for each type of product indicated.

SECTION AIR COILS

Sheltering your value. Pre-fabricated Building

1 29SEP03 ALL General update with miscellaneous changes in entire document.

SECTION HEAT TRACING FOR PLUMBING PIPING

Request for Bids. At The Greenville-Spartanburg International Airport

Capital Projects Group Gas Fired Warm Air Furnace Specification

T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ

SECTION CORIOLIS MASS FLOW MEASURING SYSTEM

Chapter 1. Introduction to Instrumentation and Process Control (Systems and Applications)

Chapter 1. Introduction to Instrumentation and Process Control (Systems and Applications)

NPS/001/024 Technical Specification for Low Voltage Aerial Bundled Conductor Fittings

A. This Section includes the following types of dry-type transformers rated 600 V and less, with capacities up to 1000 kva:

PARTICULAR SPECIFICATION E11: GENERAL ELECTRICAL EARTHING AND LIGHTNING PROTECTION

Pipeline Construction

SECTION GROUNDING AND BONDING

8. REVENUE METERING. Operational Excellence Model. 8.1 Introduction

SECTION HEAT TRACING FOR PLUMBING PIPING

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered.

Process Line Control Solutions. Rockwell Automation Drive Systems

TABLE OF CONTENTS II. MISSION VISION & OBJECTIVES... 4 III. SERVICES ) INDUSTRIAL AUTOMATION SOLUTIONS... 5 I.

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

INDEX. Page SECTION 1.0: SCOPE Toronto Hydro Requirements Ontario Electrical Safety Code 1 SECTION 2.0: PURPOSE 1

Robert E. McMains Date Robert E. McMains Date

A. This Section includes the following sump pumps and accessories, inside the building, for building storm drainage systems:

Flexible, Centralised, Decentralised & Local Solutions for Automation of Hygienic Processes

ICEA STANDARD FOR DISTRIBUTION FRAME-WIRE TECHNICAL REQUIREMENTS. Published By INSULATED CABLE ENGINEERS ASSOCIATION, INC. Post Office Box 1568

Talwandi Sabo Power Limited Tender document for Design & Engineering, Supply and Erection of Slurry pumping system from Plant to Ash Dyke

DMS CONDUIT EFFECTIVE DATE: APRIL

SECTION PRESSURE AND DIFFERENTIAL PRESSURE GAUGES

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

NYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017

UNIFIED FACILITIES GUIDE SPECIFICATIONS

TECHNICAL SPECIFICATIONS for 100Ci Ir-192 source projector(exposure device /Camera )

Capital Projects Group Mechanical Work Commissioning Specification

Union Power Cooperative

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

How do you achieve perfect integration of the entire infrastructure for a solar factory?

A. This section includes the requirements for the following chemical feed systems:

SENTRAN. Low Profile Load Cell. For more information call

NEW GC-16 IN WEST KUWAIT MATERIAL REQUISITION FOR LEVEL GAUGE TABLE OF CONTENTS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Food & Beverage Portfolio

THE KENYA POWER AND LIGHTING CO. LTD

Section ARMORED MEDIUM VOLTAGE CABLES SHIELDED 3 CONDUCTOR POWER CABLE - INTERLOCKED ARMOR

SECTION WIRES AND CABLES

MATERIAL STANDARD FOR COLD-APPLIED LAMINATED PLASTIC TAPE INNER-LAYER TAPE FOR TAPE COATING SYSTEM OF BURIED STEEL PIPES ORIGINAL EDITION JULY 1994

SECTION CONVECTORS

1DIVISION 15- MECHANICAL Section Fire Pumps. A. Single Stage, Double Suction, 9100 Series Horizontal Splitcase Fire Pump (Base Mounted)

STANDARD TECHNICAL SPECIFICATION FOR ROTAMETER VOLUME - IIB. SPECIFICATION No: PE-SS I010

3 rd Floor, Godrej Eternia - C, Wakdewadi, Shivaji Nagar, Pune , India Tel.: , Fax:

TECHNICAL SPECIFICATIONS for 100Ci Co-60 source projector(exposure device /Camera )

CONTENTS. B. System Design and Performance Requirements

SECTION PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS

Transcription:

Page : 1 of 9 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES 2 DEFINITIONS AND TERMINOLOGY 3 SYMBOLS AND ABBREVIATIONS 5 COMMON TECHNICAL FEATURES 5 PRESSURE TRANSMITTERS 6 PRESSURE INDICATORS 8 PRESSURE SWITCHING 8

Page 2 of 9 SCOPE This Project Standards and Specifications is intended to cover the selection, engineering design and establishing of criteria associated with Pressure Measurement which shall cover the following: - Directly connected measurement - Indirectly connected measurement - Differential pressure measurement - Pressure indication - Pressure switching REFERENCES Throughout this Standard the following dated and undated standards/codes are referred to. These referenced documents shall, to the extent specified herein, form a part of this standard. For dated references, the edition cited applies. The applicability of changes in dated references that occur after the cited date shall be mutually agreed upon by the Company and the Vendor. For undated references, the latest edition of the referenced documents (including any supplements and amendments) applies. 1. AASHO (American Association for State Highway Officials) 2. ANSI (American National Standards Institute) 3. ASME (American Society of Mechanical Engineers) 4. ASTM (American Society of Testing Materials) 5. BS (British Standards) 6. IEC (International Electrotechnical Commission) 7. IEEE (Institute of Electrical and Electronic Engineers) 8. IES (Illuminating Engineering Society) 9. IPCEA (Insulated Power Cable Engineers Association) 10.ISA (Instrumentation, Systems and Automation Society) 11.ISO (International Organisation for Standardisation) 12.NEC (National Electrical Code) 13.NEMA (National Electrical Manufacturers Associates) 14.NFPA (U.S. National Fire Protection Association)

Page 3 of 9 15.OSHA (Occupational Safety and Health Association) 16.SAMA (Scientific Apparatus Makers Association) 17.SANS (South African National Standards) 18.UL (Underwriters Laboratories) DEFINITIONS AND TERMINOLOGY Analogue - The variable signal transmitted or received by transmitters or PLC components. Control & Instrumentation The discipline concerned with the engineering, design, procurement and implementation of instruments and associated equipment to control industrial processes and plant. Client - The end user who will take final custody of the plant after formal handover. Data Sheet - A C&I Document reflecting the condensed but exact requirements of a piece of equipment to perform a certain duty and: - The Data Sheet shall include all information pertaining to the tag number(s), environmental conditions, type, size, materials of construction, ranges, engineering units, air/power requirements, mounting methods, displays, - The Data Sheet may also invite/provide for Supplier s recommendations to assist the engineer in selections etc. - The data sheet shall provide signature spaces for the C&I Engineer as well as the Discipline Engineer who provided process, civil, mechanical and piping data. - Only the C&I Engineer and the co-responsible engineer from the other discipline(s) need to sign off and authorise the data sheet as formal. Engineer - This shall at all times be the accountable C&I engineer liable for the technical selection, design, engineering, connection diagrams, hook-up drawings, loop diagrams, location drawings, bills of quantities, loop packages and Quality Assurance documents from procurement to C1-C5 commissioning. Any representative of the engineer shall be formally authorised so as to ensure central responsibility Loop - The wiring configuration showing the field mounted instrument complete with its cabling, wires and connections form the field item through all intermediate terminal and junction boxes, marshalling terminals strips right up to the PLC I/O

Page 4 of 9 module. The drawing created for the loop is called the LOOP DIAGRAM and each loop diagram shall only reflect the components contained in the loop and all wiring, terminal and cable numbers shall be shown. Programmable Logic Controller - comprising the modules such as a central processor, on-board power supply and input/output modules for the control of equipment. Remote - Shall mean controlling of a device from a CCR or other controller not installed in the immediate vicinity of the device. Remote I/O - PLC Input/Output modules housed in field mounted cabinets away from the PLC/SCADA location. RIO - A field mounted enclosure housing remote Input/output modules with their power supplies and signal converting units, terminals etc. SCADA - A Supervisory Control and Data Acquisition system normally comprising the HMI, associated servers and UPS units for power independence. Specification - A C&I Document which is deemed Project Standard and Specification reflecting the exact technical requirements of equipment required to perform a specific function in terms of its technical criteria: - A Specification shall reflect all the environmental, climatic, individual plant and process conditions which the equipment will be subject to, the expectations of its performance and the tolerances within which the equipment is to perform. - The Specification shall further reflect process criteria within which the equipment shall perform. There may be certain aspects not mentioned in the Specification being left for the Supplier s recommendations. - The Specification shall reflect the crating, packaging, addressing and delivery instructions in both Enquiry and Procurement instances. - The Specification shall reflect the required documentation to be submitted by the Tenderer or Supplier. - The Specification shall reflect the calibration requirements associated with equipment. - The Specification shall reflect the special tools if and when required. - The narrative within a Specification shall then be condensed onto a Data Sheet. Standard - A document reflecting the minimum criteria and technical standards the C&I engineer will use as his guideline for selection of the correct instrument for the correct application.

Page 5 of 9 Supplier - The successful supplier of equipment & instruments culminating from enquiries, tenders and adjudication processes. SYMBOLS AND ABBREVIATIONS SYMBOL/ABBREVIATION DESCRIPTION BCEW Bare Copper Earth Wire C&I Control & Instrumentation CCR Central Control Room normally housing the PLC, SCADA and I/O cubicles. HMI Human Machine Interface such as PC keyboard & monitor combinations or panel mounted operator stations. I/O The Input/Output modules associated with PLC controllers. PLC Programmable Logic Controller PVC Polyvinyl Chloride plastic insulation used with electric cables. TCP/IP Transmission Control Protocol / Internet Protocol. UPS Uninterruptible Power Supply normally floor standing, battery backed-up. COMMON TECHNICAL FEATURES Pressure transmitters generally have common features such as power supply requirements and output signals. The following shall then be taken into consideration during selection and design: 1. Power requirements shall mean the mains supply which shall be in accordance with the Project official voltages 2. Signals to the PLC may be analogue (typically 4-20mA) 3. The transmitter may be furnished with SMART transmission in which event the signals shall be led to the PLC via field bus systems 4. Loop powered instruments, two and three wire configurations, shall be connected to the matching I/O modules 5. Protection rating of instruments shall be minimum IP 65 6. SMART Instruments Where using SMART instruments the criteria below shall be adhered to. Assuming this would typically be a field bus application (typically Profibus PA) the C&I Engineer shall then incorporate the following:

Page 6 of 9 a. Ensure that the cable distance limitations are not exceeded. Where distances becomes a problem use shall be made of the correct extending hardware b. Ensure that the number of nodes is not exceeded and where this becomes a problem, use shall be made of the correct extending hardware c. Bus systems incorporating power supply must be fed from cards or sources of the correct capacity d. The C&I Engineer shall specify the use of the correct tools for terminating of field bus cables and the subsequent testing e. The Supplier shall ensure that the correct version of the configuration file (e.g. GSD, certified by the relevant authority) is supplied with transmitters intended for fieldbus applications PRESSURE TRANSMITTERS Pressure monitoring may be done by direct contact with the vessel/pipe containing the measured medium or by isolating the pressure detector form the medium using a diaphragm and capsule arrangement filled with a liquid such as Miriam oil etc. which transfers the deflections of the diaphragm to the electronic components of the transmitter. The following criteria shall be considered: 1. Direct Measurement With direct measurement application the transmitter is connected to the vessel/pipe using tubing and an interface connector to the vessel. In this event the following shall be adhered to: - The impulse tubing shall in all cases be 12mm OD stainless steel - There is very little limitations to the length of tubing but practical considerations will determine the closest position of the transmitter to the connection point - All tubing connectors and unions shall be of stainless steel with compressed nutand ferrule connections - Impulse tubing shall be pressure tested to 150% of the pressure measured - Impulse tubing installations shall be leak tested using soapy solutions and no leaks shall be tolerated 2. Indirect Measurement Indirect measurement shall be done using a capsule and diaphragm assembly filled with the appropriate sealing liquid.