Building and Environment

Similar documents
Assessment possibilities of thermal comfort by micro scale models

Human thermal comfort below the canopy of street trees on a typical Central European summer day

Visitors subjective estimations on thermal environment in public urban spaces

Modelling the thermal bioclimate in urban areas with the RayMan Model

Watts in a comfort index:

Impact of urban morphology on Microclimatic conditions and outdoor thermal comfort A study in mixed residential neighbourhood of Chennai, India.

CITY WEATHERS: METEOROLOGY AND URBAN DESIGN

Initial development of protocols for the study of outdoor thermal comfort. Johansson, Erik; Emmanuel, Rohinton; Thorsson, Sofia; Krüger, Eduardo

4.2 PHYSIOLOGICALLY EQUIVALENT TEMPERATURE AND CLIMATE CHANGE IN FREIBURG

Assessment of Thermal Comfort in Respect to Building Height in a High-Density City in the Tropics

Towards green design guidelines for thermally comfortable streets

Passive Cooling Design Options to Improve Thermal Comfort in an Urban District of Rome, Under Hot Summer Conditions

URBAN HEAT ISLAND MITIGATION: LOOKING BEYOND POLICIES TO LOWER AIR TEMPERATURE

The utilization of first derivatives and violinplots of meteorological parameters for the evaluation of thermal behavior of small urban sites.

Climate-sensitive urban growth: outdoor thermal comfort as an indicator for the design of urban spaces

Influence of Urban Morphology on Outdoor Thermal Comfort in Summer: A Study in Tunis, Tunisia

Behaviour of People in Open Spaces in Dependence of Thermal Comfort Conditions

Green Space Influence on Thermal Comfort Contrasting approaches in the assessment of conditions in Bragança (Portugal)

Adaptive Outdoor Thermal Comfort at an Urban Park in Malaysia

Thermal Comfort in Outdoor Environment

Research Article Thermal Comfort for Urban Parks in Subtropics: Understanding Visitor s Perceptions, Behavior and Attendance

Mitigating and adapting thermal stress with urban green - Quantification with measurements and micro scale models. Andreas Matzarakis

Outdoor Thermal Comfort in the Hot Arid Climate The effect of socio-economic background and cultural differences

Available online at ScienceDirect. Procedia Engineering 169 (2016 )

SENSITIVITY OF THERMAL CONDITIONS FOR TOURISM TO CLIMATE CHANGE AND VARIABILITY: A COMPARISON OF REGIONAL SCALE CASE STUDIES

Outdoor Thermal Comfort of Two Public Squares in Temperate and Dry Region of Esfahan, Iran

Thermal comfort conditions in outdoor spaces

Thermal environment and thermal comfort in a passive residential building in the severe cold area of China

Field Observation on Thermal Environment of an Urban Street with Roadside Trees in a Tropical Climate

Influence of different urban configuration on human thermal conditions in a Typical Subtropical Coast City Case of Santos, São Paulo

Thermal Bioclimate for Tourism: Case Study of Kuta, Bali Province, Indonesia Nyoman Sugiartha #1, Andreas Matzarakis *2

Microclimatic effects of trees and vegetative ground cover in a hot-arid urban environment David Pearlmutter

Urban Greening and the UHI: Seasonal Trade-offs in Heating and Cooling Energy Consumption in Manchester, UK

Perception of Thermal Comfort for Naturally Ventilated High School Classrooms in San Rafael, CA

Public Open Space Design Study on the Basis of Microclimate and Spatial Behavior in Hot and Cold Weather Conditions in Downtown Area

Outdoor Comfort: the ENVI-BUG tool to evaluate PMV values point by point

The Impact of Urban Texture in Outdoor Thermal Comfort

REDEFINING APPROPRIATE THERMAL COMFORT STANDARD FOR NATURALLY VENTILATED BUILDINGS IN TROPICS (SINGAPORE AND INDONESIA PERSPECTIVE)

Thermal comfort evaluation of natural ventilation mode: case study of a high-rise residential building

Urban Climatic Mapping in Hong Kong

Published online: 04 Sep 2013.

Procedia - Social and Behavioral Sciences 216 ( 2016 )

UHI and Thermal Performance of Office Buildings in Bangkok

Microclimate and Thermal Comfort of Urban Spaces in Hot Dry Damascus. Influence of urban design and planning regulations

ScienceDirect. Simulation based mixed mode building design

The thermal effects of city greens on surroundings under the tropical climate

THERMAL COMFORT OF A COURTYARD IN GUANGZHOU IN SUMMER

Adaptive Thermal Comfort in Warm Dry Climate: Economical dwellings in Mexico

Thermal Perception of Users of Different Age Groups in Urban Parks in Warm Weather Conditions

CBD greening and Air Temperature Variation in Melbourne

The effect of land cover and land use on urban heat island in Taiwan

Field investigation on indoor thermal environment of a high-rise condominium in hot-humid climate of Bangkok, Thailand

Statistical Model Evaluation and Calibrations for Outdoor Comfort Assessment in South Florida.

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

Thermal comfort comparison and evaluation in different climates

Assessing the representativeness of thermal comfort in outdoor spaces

Greening the desert city: The challenge of microclimatic moderation in arid urban areas

Impact of Increasing the Height of Tel Aviv Buildings on Pedestrian Comfort and Building Energy Efficiency

Green Façades for Urban Comfort Improvement Implementation in a extreme Continental Mediterranean climate

Assessing climate for tourism purposes: Existing methods and tools for the thermal complex

HUMAN-BIOMETEOROLOGICAL ASSESSMENT OF THE AIR POLLUTION COMPONENT OF THE URBAN CLIMATE BY THE INDEX DAQX

THE EFFECTS OF URBAN HEAT ISLAND MITIGATION STRATEGIES ON THE OUTDOOR THERMAL ENVIRONMENT IN CENTRAL TOKYO A NUMERICAL SIMULATION

Cities 29 (2012) Contents lists available at SciVerse ScienceDirect. Cities. journal homepage:

Microclimate improvement through redesign of open urban areas with bioclimatic criteria in a city centre

Effect of High-albedo Materials on Pedestrian Thermal Sensation in Urban Street Canyons in Hot Climates

Urban Redevelopment and Microclimate Improvement: A Design Project in Thessaloniki, Greece

Work Package 2: Performance of naturally ventilated buildings

Urban Heat Island 城市熱島效應

COMPARATIVE SUMMER THERMAL AND COOLING LOAD PERFORMANCE OF NATURAL VENTILATION OF CAVITY ROOF UNDER THREE DIFFERENT CLIMATE ZONES

Reduction of Mean Radiant Temperature by Cluster of Trees In Urban and Architectural Planning In Tropical Climates

Assessment of outdoor thermal comfort and its relation to urban geometry

UNDERSTANDING CLIMATE FOR ENERGY EFFICIENT OR SUSTAINABLE DESIGN

A first look at the affect of outdoor planting on the indoor environment of St. Loyes Residence. David Coley. March 2011 Internal Document 776

Cool spots in hot climates: a means to achieve pedestrian comfort in hot climates

Heat Stress Conditions. Prof. Dr. Lutz Katzschner University Kassel /Germany

ABSTRACT INTRODUCTION

SOLAR RADIATION ESTIMATION UNDER CLEAR SKY CONDITIONS FOR BRAŞOV AREA (ROMANIA) LINKE TURBIDITY FACTOR

SUSTAINABILITY STRATEGIES IN BUILDING DESIGN

Energy and indoor temperature consequences of adaptive thermal comfort standards

Effects of the Building Typology on PET Value in Different Local Climate Zones: A Case Study in Beijing, China

Effects of tall building envelope technologies and design strategies on the urban microclimate in hot arid regions

SUBJECTIVE AND MEASURED THERMAL COMFORT IN ITALIAN UNIVERSITY CLASSROOMS IN HEATED AND FREE RUNNING CONDITIONS

PREDICTION OF THERMAL SENSATION IN NON-AIR- CONDITIONED BUILDINGS IN WARM CLIMATES

Designing outdoor spaces with COMFORT-EX

Influence of Building Orientation on the Indoor Climate of Buildings

AIR TEMPERATURE AND THERMAL COMFORT CONDITIONS IN MOUNTAINOUS AND URBAN REGIONS

Microclimate Effects of Urban Geometry on Outdoor Thermal Comfort in the Brazilian Tropical Semi-arid Climate

Introduction ABSTRACT

GREEN CONCEPT OF THERMAL COMFORT DESIGN FOR SUSTAINABLE HOUSING IN THE TROPICS: Learning from Thermal Comfort in School Buildings 1 INTRODUCTION

FACING HEAT WAVES IN THE URBAN MICROCLIMATE

Urban greenery: increasing resilience to climate change through green roofs and urban forestry

Thermal Comfort Evaluation of HDB flats

Bioclimatic Design Approach Integration into Architectural Design: a Library Case Study

Vegetation effects on urban street microclimate and thermal comfort during overheated period under hot and dry climatic conditions

Parametric Louver Design System Based On Direct Solar Radiation Control Performance

An Assessment of Thermal Comfort in Hot and Dry Season (A Case Study of 4 Theaters at Bayero University Kano)

Research Article Application of Microclimate Modelling and Onsite Survey in Planning Practice Related to an Urban Micro-Environment

171: An urban office designed for the southern Brazilian climate

Effect of Street Morphology on Microclimate in Residential Areas Following FAR Rule in Dhaka City

Nocturnal natural ventilation for low and zero energy office buildings in Central Chile

Transcription:

Building and Environment xxx (2010) 1e8 Contents lists available at ScienceDirect Building and Environment journal homepage: www.elsevier.com/locate/buildenv Seasonal effects of urban street shading on long-term outdoor thermal comfort Ruey-Lung Hwang a, Tzu-Ping Lin b, *, Andreas Matzarakis c a Department of Architecture, National United University, 1 Lien Da, Miaoli 360, Taiwan b Department of Leisure Planning, National Formosa University, 64 Wen-Hua Rd, Huwei, Yunlin 632, Taiwan c Meteorological Institute, Albert-Ludwigs-University Freiburg, Werthmannstr. 10, D-79085 Freiburg, Germany article info abstract Article history: Received 20 July 2010 Received in revised form 12 October 2010 Accepted 16 October 2010 Keywords: Shading effect Urban streets Outdoor thermal comfort Sky view factor As shading, an important factor in urban environments, affects thermal environments and long-term thermal comfort, this study conducted several field experiments to analyze the outdoor thermal conditions on urban streets in central Taiwan. The RayMan model was utilized for predicting long-term thermal comfort using meteorological data for a 10-year period. Analytical results indicate that slightly shaded areas typically have highly frequent hot conditions during summer, particularly at noon. However, highly shaded locations generally have a low physiologically equivalent temperature (PET) during winter. Correlation analysis reveals that thermal comfort is best when a location is shaded during spring, summer, and autumn. During winter, low-shade conditions may contribute to the increase in solar radiation; thus, thermal comfort is improved when a location has little shade in winter. We suggest that a certain shading level is best for urban streets, and trees or shade devices should be used to improve the original thermal environment. Ó 2010 Elsevier Ltd. All rights reserved. 1. Introduction Outdoor thermal comfort of people are affected by thermal environment, moreover, people s usage of outdoors are affected by their perception of outdoor thermal conditions[1e4]. Furthermore, outdoor thermal environments are significantly affected by the design of built environment [5e10]. Since shadings can block direct solar radiation, numerous studies examine the effects of shading on outdoor thermal environments. For instance, previous studies [11e18] quantified the height/width (H/W) ratio of urban streets to assess shading levels, whereas the sky view factor (SVF) was used in other studies as representative of shading levels [19e23]. Ali-Toudert and Mayer, who simulated microclimatic changes by applying the ENVI-met model to an urban environment in Ghardaia, Algeria [15,16], determined that the spatial distribution of physiologically equivalent temperature (PET) at the street level depended strongly on the H/W ratio of urban streets. Emmanuel et al. [13] conducted field experiments at five locations during spring in the city of Colombo, Sri Lanka. They calculated the mean radiant temperature (Tmrt) and PET using the RayMan model [24], and found that deep street canyons (i.e., highly shaded streets) improved the outdoor thermal comfort of pedestrians. Lin et al. [25] indicated that studies with few field experiments can elucidate * Corresponding author. Tel.: þ886 5 631 5890; fax: þ886 5 631 5887. E-mail address: tplin@nfu.edu.tw (T.-P. Lin). characteristics measured (or simulated) on a particular day and likely do not represent annual thermal conditions. Therefore, they conducted several field experiments to analyze outdoor thermal conditions at a university campus in central Taiwan, and employed the RayMan model for predicting long-term thermal comfort using meteorological data for a 10-year period. The thermal comfort range of PETs of Taiwanese residents obtained in a previous study [26] was also applied as the criterion for determining whether a thermal environment is comfortable or uncomfortable. However, some issues related to shading on urban streets need further clarification. First, previous studies have not discussed the relationship between shading and thermal comfort in different seasons. Since a thermal environment may be comfortable in summer and cold in winter under the same amount of shade, the thermal comfort of a location must be addressed in different seasons. Furthermore, thermal comfort may vary at different times of the day (e.g. hot at noon and cool in the morning); thus, one must also determine the thermal comfort distribution during a given day to elucidate the thermal conditions at different times. Buildings on Taiwan s traditional streets are mostly residential and commercial, i.e., the first floor is rented by stores and all other floors are residential. If these buildings are not designed with an arcade on the ground floor and lack shading, people must walk beside the street while shopping, and are exposed to the outdoor climate. Thus, people may not be satisfied with their shopping experiences when they feel uncomfortable in an outdoor thermal environment, adversely affecting store revenue and reducing rental 0360-1323/$ e see front matter Ó 2010 Elsevier Ltd. All rights reserved. doi:10.1016/j.buildenv.2010.10.017

2 R.-L. Hwang et al. / Building and Environment xxx (2010) 1e8 prices. Therefore, investigating thermal comfort on urban blocks is essential to the economy. The aims of this study were to conducted field experiment in traditional urban streets in Taiwan; establish the prediction model for the thermal environments based on the long-term meteorological data; evaluate the long-term thermal comfort frequencies based on the local thermal comfort criteria; examine the seasonal effects of urban street shading on longterm outdoor thermal comfort. 2. Research Approach 2.1. Outdoor thermal comfort indices Several indices that integrate thermal factors based on the energy balance of the human body, SET* [27], OUT_SET* [28] and PET [29], are employed in assessing outdoor thermal comfort. Notably, PET is defined as air temperature (Ta) at which, in a typical indoor setting (Ta ¼ Tmrt; vapor pressure (Vp) ¼ 12 hpa; and wind speed (v) ¼ 0.1 m/s), the heat budget of the human body is balanced with the same core and skin temperature as those under complex outdoor conditions [30,31]. In this study, we apply PET for the main thermal comfort index for the following reasons. The first reason is that PET have been employed in several studies of outdoor thermal comfort [32e34] and is included in guideline 3787 of the German Association of Engineers (VDI) [29]. Furthermore, the thermal comfort criteria of PET have been modified and adopted setup for different climate regions [26,35]. The second reason is that PET can be estimate by the RayMan model, has been utilized in urban built-up areas and to generate predictions of thermal comfort in outdoor environments [24,36e38]. Lin et al. [25] indicated that the PET can be easily estimated by Ta, relative humidity (RH) (or Vp), v, Tmrt, human clothing and activity in the model. If more information is offered, the Tmrt (the most important factor during hot condition when calculating PET) can be also estimated by global radiation (Gr), cloud cover (Cd), fisheye photographs, albedo, the Bowen ratio of ground surface and the Linke turbidity to include the shading effect while calculating short- and long-wave radiation fluxes. Besides PET and Tmrt, the sky view factor (SVF), i.e. the ratio of free sky spaces to the entire fisheye view at a certain location, can also be calculated using the RayMan model for subsequent analyses. 2.2. Local thermal comfort criterion for PET Previous studies examining thermal adaptation indicated that occupant thermal sensations and preferences vary considerably due to differences in behavioral adjustment, physiological acclimatization, and psychological habituation or expectations [39], all of which may contribute to different thermal comfort ranges, i.e., the range of thermal indices at which people feel comfortable. Therefore, the thermal comfort range for a particular region may not be applicable to other regions. In this study, the thermal comfort range is acquired from a field survey of 1644 subjects in Taiwan [26]. In this survey, 26e30 C PET was the neutral sensation, 18e22 C PET was slightly cool, 14e18 C PET was cool, and <14 C PET was cold ; additionally, 30e34 C PET was slightly warm, 34e38 C PET was warm, 38e42 C PET was hot, and >42 C PET was very hot. As these thermal comfort ranges have been applied generally in Taiwan, a hot and humid country [25], these thermal comfort ranges are applied as criteria in this study to determine whether a thermal environment is comfortable or uncomfortable for local residents. 2.3. The field experiment This study chose streets for measurements that are almost walking spaces and with many commercial businesses (e.g., D E K F B C A Fig. 1. Studied area and measurement locations in Huwei Township.

R.-L. Hwang et al. / Building and Environment xxx (2010) 1e8 3 Table 1 Fisheye and street photographs and the SVF of each measurement location. Fisheye photo Street photo SVF A B C 0.236 0.309 restaurants and stores) and were not interfered with by traffic or huge air-conditioners. Therefore, a traditional street in Huwei Township, located at 23 43 0 N, 120 26 0 E at an elevation of 20 m above sea level, was selected. Fig. 1 shows the area surveyed in this study. Measurement locations AeF, which are outdoor spaces most frequently used by local residents, are characterized by different shading levels. Point K, a reference for locations AeF, is located on the roof of a 10 m-high building with no shade. Table 1 shows fisheye and street photographs and the SVF of each measurement location. Among the six measurement locations, the SVF ranges from highly shadeddpoint A (SVF ¼ 0.236)d to slightly shadeddpoint F (SVF ¼ 0.616) (Table 1). To measure physical thermal parameters, survey instruments were placed at 1.1 m above ground level on a tripod at locations AeF and K to measure Ta, RH, and globe temperature (Tg). At location K, v and Gr were also measured simultaneously. Measurements were recorded at 1-min intervals automatically from 08:00 to 18:00, as this is the period when shoppers are outdoors most; thus, this period is also the period used in subsequent analyses. Four field experiments were conducted, one in each season, to ensure data representativeness of climate characteristics in each season. D E F K 0.326 0.348 0.555 0.616 0.879 2.4. Validation of RayMan model The RayMan model must be validated by comparing field measurements and model simulation results to fit the local climate and urban context. Since Tmrt is an integrated thermal index representing the combination of Ta, v, and short- and long-wave radiation fluxes, and can be determined via both measurements and simulations, the consistency between measured and modeled Tmrt was utilized as a criterion for model validation. The measured Tmrt was calculated using Ta, Tg, and v based on ISO standard 7726 [40]. The mean convection coefficient was corrected using the method developed by Thorsson et al. [41]. The modeled Tmrt was calculated using the RayMan model by importing the same factors used in calculating PET. According to the method applied in Lin et al. [25], Tmrt for each location is estimated by Gr, cloud cover, fisheye photographs and other climatic and environmental factors during the experiments. 2.5. Simulation of long-term thermal environment conditions Long-term meteorological data from weather stations were imported into the model with optimal settings for predicting longterm variations in thermal environmental conditions and thermal indices. The meteorological hourly data for the 10-year period of 2000e2009 utilized in this study acquired were from the nearest weather station; this weather station is in Chiayi. The Ta, RH, v, Gr, and Cd of hourly data were imported into the RayMan model. Since meteorological data were not acquired in the surveyed area and cannot directly represent the thermal conditions at measurement locations AeF, we assume the thermal conditions at measurement locations are related to meteorological data, and these data must be corrected before being imported into the model. For estimations of thermal conditions at each location, as the closest weather station is near Huwei Township, and the slightly shaded location K has as a height and sky conditions similar to those at the weather station, climate data at K were assumed close to those measured at the weather station. According to the method used in Lin et al. [25], the long-term Ta, v, and Gr for each locations is then modified by climate data of weather station based on regression analysis. The regressive functions of Ta for each location are highly correlated to experimental result (R 2 ¼ 0.92e0.96, p-value < 0.001) in this study.

4 R.-L. Hwang et al. / Building and Environment xxx (2010) 1e8 Table 2 Mean values of physical measurements for location K on each measurement day. Values in parentheses are minimum and maximum. Season Date Air temperature ( C) Relative humidity (%) Wind speed (m/s) Global radiation (W/m 2 ) Winter 2009/1/11 16.9 (9.3e20) 53.9 (46.3e72.7) 1.4 (0.6e2.3) 402.5 (0e671.4) Spring 2009/3/22 29.7 (25.9e32.6) 65.8 (54.1e82.2) 2.2 (0.6e3.6) 423.8 (43.6e808.2) Summer 2009/8/1 34.2 (30.1e36.4) 61.6 (53.6e82.1) 0.9 (0.3e1.6) 535.6 (125.5e953.2) Autumn 2008/10/18 32.2 (27.9e35.9) 64 (48e80) 0.7 (0.3e1.7) 469.3 (5e913.4) 3. Results and discussion 3.1. Field experiment results and model validation Field experiments were conducted on January 11, 2009, during winter, on March 22, 2009, during spring, on August 1, 2009, during summer, and on October 18, 2008, during autumn. Measurements were recorded from 08:00 to 18:00 on each day. For location K (Table 2), mean Ta in winter was <20 C, while Ta in the other seasons was >30 C. The average RH was 54e64% and average wind speed at each measured day was <2.5 m/s. Average Gr was 400e600 W/m 2 ; the highest Gr values in summer, spring, and autumn were always >800 W/m 2. These data characterize the local Tmrt (ºC) 60 50 40 Tmrt Measured Tmrt Modelled climate as hot in summer and mild in winter with high humidity all year. Fig. 2 shows the variation in both measured and modeled Tmrt for cases in spring (March 22, 2009). The modeled Tmrt and measured Tmrt have similar trends and values. The measured Tmrt and modeled Tmrt were strongly correlated (R 2 ¼ 0.88, P < 0.001) (Fig. 3), demonstrating that the model is accurate in predicting Tmrt and PET. a Frequency of the warm condition (PET>30) 10 8 6 4 2 A B C D E F 30 20 8:00 13:00 8:00 13:00 8:00 13:00 8:00 13:00 8:00 13:00 8:00 13:00 70 A B C D E F Time Fig. 2. Variation in both measured and modeled Tmrt for cases in spring (March 22, 2009). b Frequency of the cool condition (PET<26) 10 8 6 4 2 Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 60 A B C D E F Modeled Tmrt ( C) 50 40 30 y = 0.9557x + 1.9751 R 2 = 0.8834 20 10 0 0 10 20 30 40 50 60 70 Measured Tmrt ( C) Fig. 3. Correlation between measured and modeled Tmrt. c Frequency of the comfortable condition (26-30 C PET) 7 6 5 4 3 2 1 A B C D E F Fig. 4. Predicted frequencies for the warm condition (a), cool condition (b) and thermal comfort condition (c) at 08:00e18:00, 2000e2009.

R.-L. Hwang et al. / Building and Environment xxx (2010) 1e8 5 3.2. Long-term thermal perceptions frequencies According to the assumptions and prediction method discussed in Section 3.3, meteorological data were corrected and imported into the model to derive hourly PET over the last 10 years. While expressing the calculated PET, the frequencies of three thermal sensation classifications were calculated based on the thermal comfort range in Taiwan. The first is the frequency of the warm condition; that is, the percentage of warm hours (PET > 30 C) over total hours during a specific period, which is expressed as F PET>30 (Fig. 4(a)). The second is the frequency of the cool condition, i.e., F PET<26 (Fig. 4(b)), and the third is the frequency of the comfortable condition, i.e., F 26<PET<30 (Fig. 4(c)). These three frequencies are calculated using hourly data for the 10-year period of 2000e2009 and are presented in 10-day intervals (36 intervals/year) to increase data resolution. Since the original field experiment time and model validation period are both during 8:00e18:00, long-term simulation results are more reliable during 8:00e18:00 than the rest time of a day. Therefore, we only displayed the simulation results between 8:00e18:00 in this study. The F PET>30 was high in summer and low during the other seasons for all locations (Fig. 4(a)). The F PET>30 values for highly shaded locations (i.e., A and B) were <4 throughout the whole year, while that of the slightly shaded location (i.e., F) was >6 during June to August. However, the F PET<26 was low in summer, spring, and fall and high in winter at all locations (Fig. 4(b)). The F PET<26 values for highly shaded locations (i.e., A and B) were close to 10 during winter, while that for slightly shaded location F was much lower than those for the remaining locations during winter, spring, and autumn. The F 26<PET<30 of the slightly shaded location, F, was 10e3 all year, while that of the highly shaded locations, A, and B, was high in summer and low in winter (Fig. 4(c)). This is because the warm condition at these highly shaded locations seldom occurred during summer (F PET>30 < 4) and cool conditions were extremely frequent during winter (F PET<26 almost 10); thus, thermal comfort peaked in summer and was rare in winter at highly shaded locations. Therefore, different shading levels contribute to the variation in the thermal perception distribution. 3.3. Mean thermal sensations at different periods in a day However, the frequency of each thermal perception acquired in the previous sections is difficult to use when interpreting thermal comfort variations during a given day (e.g., differences between morning and afternoon). Since several studies revealed that there are significant time-induced effects on thermal comfort or user response under a changing conditions within a day [11,15,31], this study generated the PET isotherm for each location for further elucidation. Fig. 5 shows a PET isotherm, where the x-coordinate refers to the month and the y-coordinate is time. This study calculated PET averages for different times for each 10-day period using PET data for 2000e2009. For example, PET at 8:00 on Jan. 1e10 was the average of 100 climate data (10 year 10 days) at 8:00 from Jan. 1 to 10 in 2000e2009. Based on this principle, this study calculated PET and generated the PET isotherm using the Kriging algorithm in the SurferÒ program. This study chose three locations with different levels of shading to determine their PET isotherm, i.e., highly shaded A (SVF ¼ 0.236), a b c Time Time Time Location A (SVF=0.236) 18:00 16:00 14:00 12:00 10:00 8:00 Location E (SVF=0.555) 18:00 16:00 14:00 12:00 10:00 8:00 Location F (SVF=0.616) 18:00 16:00 14:00 12:00 10:00 8:00 Very hot 42 Hot 38 Warm 34 Slightly warm 30 Neutral 26 Slightly cool 22 Cool 18 Cold 14 Very cold 10 6 PET (deg C) Fig. 5. Predicted PET isotherm for locations A(a), E(b), and F(c), 2000e2009.

6 R.-L. Hwang et al. / Building and Environment xxx (2010) 1e8 moderately shaded E (SVF ¼ 0.555) and slightly shaded F (SVF ¼ 0.616). For location A (Fig. 5(a)), the thermal comfort period (white) was from July to September except at noon, and at noon during May, June, and October. Slightly warm (PET > 30 C) was at noon during July to September. Slightly cool (PET < 26 C) was distributed from November to April. For location E (Fig. 5(b)), the thermal comfort period was shorter and the slightly warm period was longer than those at location A. Slightly warm was a Frequency of PET>30 b Frequency of PET<26 c Frequency of 26<PET<30 8 7 6 5 4 Winter Spring Summer Autumn y = 0.9179x + 0.062 R 2 = 0.8866 3 y = 0.6508x - 0.1031 R 2 = 0.7265 2 1 y = 0.6164x - 0.1238 R 2 = 0.7969 y = 0.092x - 0.0279 R 2 = 0.4884 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Sky view factor (SVF) y = -0.2489x + 1.0655 10 R 2 = 0.5217 Winter 9 Spring 8 Summer y = -0.6802x + 0.9224 Autumn 7 R 2 = 0.9051 6 5 4 y = -0.5413x + 0.7954 R 2 = 0.7811 3 2 1 y = -0.2248x + 0.2784 R 2 = 0.8885 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 6 5 4 3 2 1 Sky view factor (SVF) Winter Spring Summer y = -0.693x + 0.6595 Autumn R 2 = 0.8118 y = -0.1095x + 0.3077 R 2 = 0.4587 y = 0.1569x - 0.0375 R 2 = 0.5391 y = 0.0638x + 0.2014 R 2 = 0.1767 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 Sky view factor (SVF) Fig. 6. Correlation between the SVF and frequencies of the warm condition (a), cool condition (b) and comfort condition (c) at each location on urban streets in different seasons. distributed from May to October, and warm occurred from July to September. For the slightly shaded location, F (Fig. 5(c)), slightly warm was widely distributed during March to November, almost reaching hot at noon during July to September. Therefore, the thermal sensation distribution varied at different periods in a day, revealing that the slightly shaded areas are hot at noon in summer while highly shaded areas are more comfortable throughout the whole year. 3.4. The correlation between SVF and thermal comfort for each season To assess the correlation between the SVF on urban streets in different seasons, this study analyzed the frequency of the warm condition (F PET>30 ) and frequencies of the cool condition (F PET<26 ) and comfortable condition (F 26<PET<30 ) at each location on urban streets during different seasons. First, these three frequencies at each location were calculated for each season and their SVF values were plotted (Fig. 6(a)e(c)), and fitted with a regression line for each season. The positive or negative slope of each regression line indicates whether the correlation between the SVF and frequencies are positive or negative, while the absolute value of the slope shows the sensitivities of frequencies to variation in the SVF. The correlation between the SVF and F PET>30 was positive, i.e., locations with a high SVF (slightly shaded) were hot (Fig. 6(a)). Based on the slope of the four fitted lines, the value in summer was highest, spring and autumn had a moderate value, while winter had the lowest value. These analytical results reveal that the F PET>30 is more sensitive to variation in the SVF in hot seasons than in cool seasons. Furthermore, F PET>30 was the highest in summer given the same SVF value for the same location. The correlation between SVF and F PET<26 was negative, i.e., locations with a low SVF (highly shaded) were cool (Fig. 6(b)). Based on the slope of the four fitted lines, the values for spring and autumn were highest. Analytical results demonstrate that the F PET<26 was more sensitive to the variation in the SVF in spring and autumn than in summer and winter. Furthermore, F PET<26 was highest in winter given the same SVF value for the same location. The correlation between the SVF and F 26<PET<30 was negative in winter and positive in the other seasons, i.e., locations with a high SVF are comfortable in winter and uncomfortable in other seasons (Fig. 6(c)). These experimental results reveal some important phenomena. First, shaded locations have fewer warm hours, especially in summer, than non-shaded locations. The elevation of the sun is high at noon in summer, which increases the likelihood of sunlight directly hitting the street, likely accounts for this finding. Conversely, locations with considerable shading increase the duration of cool hours. When the comfort condition is evaluated, highly shaded areas are beneficial in spring, summer, and autumn, while minimal shade is comfortable only in winter as increased sunlight (solar radiation) overcomes the original cool-air condition. Therefore, the effects of shading vary in different seasons. 4. Conclusions This study focused on six locations on urban streets in Huwei Township, central Taiwan, and discussed the effects of shading on long-term outdoor thermal comfort and seasonal variation. Four field experiments were conducted during each season to establish and validate the RayMan model for the simulation of the long-term thermal comfort based on 10-year meteorological data. The thermal comfort criterion of Taiwanese residents obtained in a previous survey was applied as the criterion for determining whether a thermal environment is comfortable or uncomfortable.

R.-L. Hwang et al. / Building and Environment xxx (2010) 1e8 7 Concerning the issue of responding time of PET in the fluctuating microclimate, it should be discussed and clarified in two stage of this research. The first part is filed experiment and model validation (section 3.2 and 3.3), due to the 1-min interval measured data is collected, the calculated PET can actually response the fluctuating change in microclimate. The second stage is Long-term simulation (3.3). Due to the available climate data is 1-h interval, the hourly data are imported to the RayMan model the calculated the long-term PET. In this research, the purpose of the long-term simulation is to describe the frequencies thermal perceptions roughly, instead of displaying the instantaneous change in microclimate precisely. Since each thermal perception is ranged about 4 C (e.g. thermal comfort is 28e30 C PET), distribution differences of thermal perception frequencies caused by the slightly microclimate fluctuating are relatively small. Furthermore, PET values based on hourly data have been used to predicted thermal comfort for many studies [15,42e45]. To sum up, we think PET index is adequate to be used in dealing with either instantaneous dynamic outdoor thermal conditions or long-term (e.g. daily, seasonally, annually) thermal condition based on hourly climate data. Analytical results indicate that slightly shaded locations typically have high frequency hot conditions in summer, especially at noon. However, highly shaded locations tend to have a relatively lower PET in winter. Correlation analysis reveals that thermal comfort is best when a location is shaded in spring, summer, and autumn. In winter, the slightly shaded condition may contribute to increased solar radiation; thus, thermal comfort is best when a location has little shade. Since the thermal comfort condition varies in different seasons, we cannot suggest a certain shading level or H/W ratio for urban streets. Furthermore, the heights of new buildings are always restricted by land use policy in urban areas and old buildings are hard to re-build. However, study results may have some significant applications. For example, some shading devices on urban streets may be added in summer and removed in winter. Additionally, deciduous trees may prove helpful in providing shade in summer and letting solar radiation enter streets in winter. Acknowledgements The authors would like to thank the National Science Council of Taiwan, for financially supporting this research under Contract No. NSC98-2221-E-150-063. Bo-Ren Su and Ching-Yu Hsueh are commended for data collection. References [1] Nikolopoulou M, Baker N, Steemers K. Thermal comfort in outdoor urban spaces: understanding the human parameter. Solar Energy 2001;70:227e35. [2] Thorsson S, Lindqvist M, Lindqvist S. Thermal bioclimatic conditions and patterns of behaviour in an urban park in Goteborg, Sweden. International Journal of Biometeorology 2004;48:149e56. [3] Eliasson I, Knez I, Westerberg U, Thorsson S, Lindberg F. Climate and behaviour in a Nordic city. Landscape and Urban Planning 2007;82:72e84. [4] Lin TP. Thermal perception, adaptation and attendance in a public square in hot and humid regions. Building and Environment 2009;44:2017e26. [5] Lin TP, Ho YF, Huang YS. Seasonal effect of pavement on outdoor thermal environments in subtropical Taiwan. Building and Environment 2007;42: 4124e31. [6] Tan SA, Fwa TF. Influence of pavement materials on the thermal environment of outdoor spaces. Building and Environment 1992;27:289e95. [7] Taha H. Urban climates and heat islands: albedo, evapotranspiration, and anthropogenic heat. Energy and Buildings 1997;25:99e103. [8] Asaeda T, Ca VT. Characteristics of permeable pavement during hot summer weather and impact on the thermal environment. Building and Environment 2000;35:363e75. [9] Wong NH, Jusuf SK, La Win AA, Thu HK, Negara TS, Wu XC. Environmental study of the impact of greenery in an institutional campus in the tropics. Building and Environment 2007;42:2949e70. [10] Ichinose T, Shimodozono K, Hanaki K. Impact of anthropogenic heat on urban climate in Tokyo. Atmospheric Environment 1999;33:3897e909. [11] Johansson E. Influence of urban geometry on outdoor thermal comfort in a hot dry climate: a study in Fez, Morocco. Building and Environment 2006;41: 1326e38. [12] Johansson E, Emmanuel R. The influence of urban design on outdoor thermal comfort in the hot, humid city of Colombo, Sri Lanka. International Journal of Biometeorology 2006;51:119e33. [13] Emmanuel R, Johansson E. Influence of urban morphology and sea breeze on hot humid microclimate: the case of Colombo, Sri Lanka. Climate Research 2006;30:189e200. [14] Ali-Toudert F, Mayer H. Thermal comfort in an eastewest oriented street canyon in Freiburg (Germany) under hot summer conditions. Theoretical and Applied Climatology 2007;87:223e37. [15] Ali-Toudert F, Mayer H. Numerical study on the effects of aspect ratio and orientation of an urban street canyon on outdoor thermal comfort in hot and dry climate. Building and Environment 2006;41:94e108. [16] Ali-Toudert F, Mayer H. Effects of asymmetry, galleries, overhanging facades and vegetation on thermal comfort in urban street canyons. Solar Energy 2007;81:742e54. [17] Emmanuel R, Rosenlund H, Johansson E. Urban shading e a design option for the tropics? A study in Colombo, Sri Lanka. International Journal of Climatology 2007;27:1995e2004. [18] Shashua-Bar L, Potchter O, Bitan A, Boltansky D, Yaakov Y. Microclimate modelling of street tree species effects within the varied urban morphology in the Mediterranean city of Tel Aviv, Israel. International Journal of Climatology 2010;30:44e57. [19] Giridharan R, Lau SSY, Ganesan S. Nocturnal heat island effect in urban residential developments of Hong Kong. Energy and Buildings 2005;37: 964e71. [20] Bottyan Z, Unger J. A multiple linear statistical model for estimating the mean maximum urban heat island. Theoretical and Applied Climatology 2003;75: 233e43. [21] Hamdi R, Schayes G. Sensitivity study of the urban heat island intensity to urban characteristics. International Journal of Climatology 2007;28: 973e82. [22] Giridharan R, Lau SSY, Ganesan S, Givoni B. Urban design factors influencing heat island intensity in high-rise high-density environments of Hong Kong. Building and Environment 2007;42:3669e84. [23] Dimoudi A, Nikolopoulou M. Vegetation in the urban environment: microclimatic analysis and benefits. Energy and Buildings 2003;35:69e76. [24] Matzarakis A, Rutz F, Mayer H. Modelling radiation fluxes in simple and complex environments e application of the RayMan model. International Journal of Biometeorology 2007;51:323e34. [25] Lin TP, Matzarakis A, Hwang RL. Shading effect on long-term outdoor thermal comfort. Building and Environment 2010;45:213e21. [26] Lin TP, Matzarakis A. Tourism climate and thermal comfort in Sun Moon Lake, Taiwan. International Journal of Biometeorology 2008;52:281e90. [27] Gagge AP, Fobelets AP, Berglund LG. A standard predictive index of human response to the thermal environment. ASHRAE Transactions 1986;92:709e31. [28] Spagnolo J, de Dear RJ. A field study of thermal comfort in outdoor and semioutdoor environments in subtropical Sydney Australia. Building and Environment 2003;38:721e38. [29] VDI. Methods for the human biometeorological evaluation of climate and air quality for the urban and regional planning. Part I: climate. VDI guideline 3787. Part 2. Berlin: Beuth; 1998. [30] Höppe P. The physiological equivalent temperature e a universal index for the biometeorological assessment of the thermal environment. International Journal of Biometeorology 1999;43:71e5. [31] Mayer H, Höppe P. Thermal comfort of man in different urban environments. Theoretical and Applied Climatology 1987;38:43e9. [32] Thorsson S, Honjo T, Lindberg F, Eliasson I, Lim EM. Thermal comfort and outdoor activity in Japanese urban public places. Environment and Behavior 2007;39:660e84. [33] Andrade H, Alcoforado M-J. Microclimatic variation of thermal comfort in a district of Lisbon (Telheiras) at night. Theoretical and Applied Climatology 2007;92:225e37. [34] Oliveira S, Andrade H. An initial assessment of the bioclimatic comfort in an outdoor public space in Lisbon. International Journal of Biometeorology 2007;52:69e84. [35] Matzarakis A, Mayer H. Another kind of environmental stress: thermal stress. WHO Collaborating Centre for air Quality Management and air Pollution Control. Newsletters 1996;18:7e10. [36] Gulyas A, Unger J, Matzarakis A. Assessment of the microclimatic and human comfort conditions in a complex urban environment: modelling and measurements. Building and Environment 2006;41:1713e22. [37] Lin TP, Matzarakis A, Huang JJ. Thermal comfort and passive design of bus shelters. In: Proceedings of 23rd conference on passive and low energy architecture (PLEA2006); 2006. Geneva.

8 R.-L. Hwang et al. / Building and Environment xxx (2010) 1e8 [38] Matzarakis A, Rutz F, Mayer H. Modelling radiation fluxes in simple and complex environments: basics of the RayMan model. International Journal of Biometeorology 2010;54:131e9. [39] Brager GS, de Dear RJ. Thermal adaptation in the built environment: a literature review. Energy and Buildings 1998;27:83e96. [40] ISO. International standard 7726, thermal environment-instruments and method for measuring physical quantities. Geneva: International Standard Organization; 1998. [41] Thorsson S, Lindberg F, Eliasson I, Holmer B. Different methods for estimating the mean radiant temperature in an outdoor urban setting. International Journal of Climatology 2007;27:1983e93. [42] Zaninovic K, Matzarakis A. The bioclimatological leaflet as a means conveying climatological information to tourists and the tourism industry. International Journal of Biometeorology 2009;53:369e74. [43] Thorsson S, Eliasson I. An intra-urban thermal breeze in Goteborg, Sweden. Theoretical and Applied Climatology 2003;75:93e104. [44] Svensson M, Eliasson I. Diurnal air temperatures in built-up areas in relation to urban planning. Landscape and Urban Planning 2002;61: 37e54. [45] Mayer H, Holst J, Dostal P, Imbery F, Schindler D. Human thermal comfort in summer within an urban street canyon in Central Europe. Meteorologische Zeitschrift 2008;17:241e50.