SOLAR MULTI-EFFECT DESALINATION SYSTEM

Similar documents
SUMMARY AND CONCLUSION

The factory assembled air handler shall conform to the requirements outlined ASHRAE 90.1.

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017

K. All mechanical rooms shall be designed with a minimum 3-1/2 dropped floor.

Chapter-2 LITERATURE REVIEW. A brief review of previous and ongoing research investigations on thermal

2. Inclined solar panel basin solar still in passive and active. mode

1. ARI 410 Standard for chilled water, hot water and steam coils. 2. ARI 430 Central Station Air Handling Units

.1 All equipment, controls and accessories to be compatible with system design, and matched to the steam boiler(s) by the boiler Manufacturer.

Horizontal Falling Film Brine Concentrator

PRODUCT DESCRIPTION PARAMETERS

Contents EN 14015:2004 (E) page

Ref. No.: SRMU/NDP-I/VBMPS-II/ INVITATION FOR QUOTATION FOR SUPPLY OF GOODS UNDER SHOPPING PROCEDURES

FRESH WATER GENERATORS ONBOARD A FLOATING PLATFORM

Plot No. 1-7/B, Laxmi Co-op Industrial Estate, Hatkanangale , Kolhapur Dist. TENDER NO D5

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

Solar Flat Plate Thermal Collector

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

Assessment Schedule - TS.5

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D

SECTION GROUND WATER STORAGE TANKS

Reverse Osmosis Desalinators

Expansion of Fosfertil s Complex in Uberaba, Brazil. Details of the increase in phosphoric acid capacity. by the addition of two evaporators.

SECTION PLUMBING PIPING SYSTEM

FXV. Closed Circuit Cooling Towers. Closed Circuit Cooling Towers. Product Detail FXV - C 1. Engineering Data FXV Models... C2

Revision:C Pipework Insulation Issued:14/11/2012 PIPEWORK INSULATION CU14. 14/11/2012 Page 1 of 10 Pipework Insulation - RevC

STEEL AUTHORITY OF INDIA LTD

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

Camel Solar brings you some of the most advanced solar thermal systems available on the market today through innovation, research and development.

SUMMARY OF PRICES FOR FOR FIRE FIGHTING WORKS FOR Phase-1,(Block-G&H) Type-B

56-SDMS-01 REV. 01 SPECIFICATIONS FOR

FIRST EVER FLOATING BARGE MOUNTED LOW TEMPERATURE THERMAL DESALINATION PLANT BY INDIAN SCIENTISTS

Lenntech. Tel Fax / Marley MS Cooling Tower /

VVER-440/213 - The reactor core

REQUEST FOR BID (TURNKEY SOLUTION) 1MW GRID TIE SOLAR PV POWER PLANT. Location:

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

SOLAR VACUUM MEMBRANE DISTILLATION FOR SEA WATER DESALINATION. Slimane GABSI,

CO2 solutions February 2018

Comfort Cooling Application Using Fixed Focus Solar Parabolic Dish Concentrator Integrated with Double Effect Vapor Absorption Machine

Technical specification. Selectively coated, %100 thermally contacted fins and absorbers for highly efficient solar thermal applications

SECTION COOLING TOWER

GENERAL MECHANICAL SYSTEM REQUIREMENTS

C. ASSE 1013 Performance Requirements for Reduced Pressure Principle Backflow Preventers.

3rd International Conference on Engineering & Gaza Reconstruction DESIGN AND MANUFACTURING OF A SOLAR WATER DISTILLATION UNIT

Section 4. Annex to IAEA Request for Proposal STATEMENT OF WORK. Primary/Secondary cooling water Heat Exchangers

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Fiber Optic Dynamic Lane Control Sign

Water headers are made of reinforced plastic and the design of the spray tree ensures uniform water distribution.

SECTION GROUND STORAGE TANK

TM Series Induced Draft Cooling Tower Specifications

A class of its own JUMAG STEAM BOILER COMPACT INFORMATION STEAM BOILER WATER SUPPLY MODULES BLOW DOWN VESSEL COMPACT STEAM SYSTEM.

20/06/2011 Seminar on Geothermal Exploitation Santiago de Chile

Phone Toll-Free Fax

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

UBC Technical Guidelines Section Edition Fume Hoods Page 1 of 5

Performance analysis of a solar still coupled with evacuated heat pipes

Solar Water Distillation System. Prepared By: Patel Jay D. Patel Jaimin R. Patel Amit J. Chaudhary Vipul M.

CENTRAL ELECTRICITY AUTHORITY NEW DELHI

MOTHER DAIRY A UNIT OF GUJARAT CO-OPERATIVE MILK MARKETING FEDERATION LIMITED PURCHASE INQUIRY

Central Station Air Handler Specification

GENERAL CONTENTS SECTION I - NUCLEAR ISLAND COMPONENTS

SCHEDULE-A MODIFIED CLAUSES/ PAGE NUMBERS: Vol. No. Section/ Description SECTION IA/ ANNEXURE XII :INPUT DRAWINGS (PT plant) Clause no of 920

Talwandi Sabo Power Limited Tender document for Design & Engineering, Supply and Erection of Slurry pumping system from Plant to Ash Dyke

MATERIAL SPECIFICATION FOR UNINTERRUPTIBLE POWER SUPPLY SYSTEMS FOR LED TRAFFIC SIGNALS

CMR Journal of Engineering and Technology Vol.2 Issue.2 April, 2018

Solar Thermal. [Strategy]

Keywords: - Waste heat Recovery, Desalination, Turbo spin heat exchanger, Heat transfer, Diesel engine exhaust

QUALITY ASSURANCE PROTOCOL (QAP)

Energy Efficient. & Cost Saving. Continuous Boiler Blowdown Package Heat Recovery Systems. 20 Models from 1,200 pph to 50,000 pph Capacity

STANDARD TECHNICAL SPECIFICATION FOR ROTAMETER VOLUME - IIB. SPECIFICATION No: PE-SS I010

SECTION FIELD ERECTED INDUCED DRAFT COOLING TOWER

B. System Design and Performance Requirements

ASI MODEL DM 100 SERIES DILUTING MODULES

Central Silk Board Central Silk Board-CMER and TI Jorhat Tender Reference Number CSB/CMERTI/ 4-50/17-18/Str/2810A dtd

Objectives and Task Analysis for the Installer of Grid Connect Photovoltaic System

WATER TREATMENT PLANT BASED ON REVERSE OSMOSIS TECHNOLOGY litres Per Hour

Developing a Design and Simulation Tool for Coupling Thermal Desalination Plants with Nuclear Reactors by using APROS Simulator

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 7 to 16 KW

BELLARY THERMAL POWER PROJECT PROJECT INFORMATION

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY SPECIFICATIONS FOR HIGH PRESSURE SODIUM LUMINAIRES, CUTOFF TYPE

PREMIER Low Profile Induced Draft Cooling Tower Specifications

PART A QUALIFYING CRITERIA FOR SUPPLY OF 65 M LONG WALKING BEAM TYPE COOLING BED

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

31-SDMS-03 REV. 01 SPECIFICATIONS FOR

SPECIFICATION CUM COMPLIANCE CERTIFICATION FOR PRESSURE TESTING PUMP

SECTION ALUMINUM GEODESIC DOME. This section includes materials, fabrication and erection of the aluminum geodesic dome.

DIAGRAM FOR CALCULATING PIPE SIZES, DISCHARGE VELOCITIES AND LOSS OF HEAD IN STANDARD STEEL PIPE PIPE FRICTION LOSS CHART

A COMPARATIVE ANALYSIS OF SINGLE SLOPE SOLAR STILL COUPLED WITH FLAT PLATE COLLECTOR AND PASSIVE SOLAR STILL

Thermal Analyses on Solar Collectors with Nano Carbon Coated Absorbers

RL SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL

Nairobi Funeral Home and Forensics INCINERATOR BILLS OF QUANTITIES

Design & Construction Standards, Revised January

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

LABORATORY & DEIONIZED WATER SYSTEMS DESIGN AND CONSTRUCTION STANDARD

MATERIAL SPECIFICATION FOR HIGH PRESSURE SODIUM LUMINAIRES FOR UNDERPASS LIGHTING

Geothermal Power Plant

Self-Priming pumps, when it really matters

Stainless steel 444 HS tube. 6m lengths

Technical Summary. 1. Purpose

Renewable energies Concepts Heat exchanger solutions. Experts for energy recovery. We make waste-heat to your profit

Design of multistage evaporators for integrating with Scheffler Solar concentrators for food processing applications.

use Solar thermal for hot water production DESIGN APPROACHES

Transcription:

OPEN TENDER TECHNICAL SPECIFICATION FOR THE PROJECT SOLAR MULTI-EFFECT DESALINATION SYSTEM SPONSORED BY MINISTRY OF EARTH SCIENCES, GOVERNMENT OF INDIA, NEW DELHI

INDEX S. NO DESCRIPTION PAGE NO. I PROJECT INFORMATION 04 II PROCESS DESCRIPTION 05 A MULTI- EFFECT DESALINATION SYSTEM 1 SCOPE OF WORK 07 2 SCOPE OF SUPPLY 07 3 MAIN COMPONENTS OF MED UNIT 07 4 INSPECTION, TESTING & ACCEPTANCE TEST 11 5 DRAWINGS & DOCUMENTS 11 6 PERFORMANCE GUARANTEE 12 7 OVERALL PROCESS SPECIFICATION 12 8 TECHNICAL SPECIFICATIONS 13 9 EXPERIENCE OF THE BIDDER 15 10 TECHNICAL DATA SHEETS- BIDDER TO FILL 15 B SOLAR WATER HEATING SYSTEM 1 SCOPE OF WORK 17 2 SCOPE OF SUPPLY 17 3 SOLAR WATER HEATING SYSTEM 17 4 MAIN COMPONENTS OF SOLAR WATER HEATING SYSTEM 5 INSPECTION, TESTING & ACCEPTANCE TEST 18 6 DRAWINGS & DOCUMENTS 19 7 STANDARDS 19 8 PERFORMANCE GUARANTEE 19 9 TECHNICAL SPECIFICATIONS 19 10 EXPERIENCE OF THE BIDDER 21 11 TECHNICAL DATA SHEETS- BIDDER TO FILL 22 18 2

C 15 kwp OFF-GRID GROUND MOUNTED SOLAR PHOTOVOLTAIC (PV) SYSTEM 1 SCOPE OF WORK 23 2 SCOPE OF SUPPLY 23 3 SOLAR PV POWER GENERATION SYSTEM 23 4 MAIN COMPONENTS OF SOLAR PV POWER GENERATION SYSTEM 5 INSPECTION, TESTING & ACCEPTANCE TEST 24 6 DRAWINGS & DOCUMENTS 24 7 STANDARDS 24 8 PERFORMANCE GUARANTEE 24 9 TECHNICAL SPECIFICATIONS 25 10 EXPERIENCE OF THE BIDDER 26 11 TECHNICAL DATA SHEETS BIDDER TO FILL 27 23 D SEA WATER INTAKE AND DRAIN SYSTEM, DISTILLATE RE-MINERALIZATION UNIT & INTEGRATION OF PLANT SUBSYSTEMS 1 SCOPE OF WORK 28 2 SCOPE OF SUPPLY 28 3 OVERALL PROCESS PARAMETERS 28 4 INSPECTION, TESTING & ACCEPTANCE TEST 29 5 DRAWINGS & DOCUMENTS 29 6 STANDARDS 29 7 PERFORMANCE GUARANTEE 30 8 TECHNICAL SPECIFICATIONS 30 9 EXPERIENCE OF THE BIDDER 31 10 TECHNICAL DATA SHEETS BIDDER TO FILL 32 3

I. PROJECT INFORMATION a. LOCATION The Solar based stand alone Sea Water Desalination System (Solar LTF MED) shall be installed at Vivekananda Kendra, Kanyakumari district of Tamil Nadu. The nearest Railway station is Kanyakumari and Airport is Trivandrum located at a distance of approximately 2 km & 90 km respectively from Project site. b. INTENT OF THE PROJECT The intent of Solar LTF-MED system is to produce Potable water from Sea Water. It is envisaged to be accomplished by utilizing the hot water produced by solar thermal collectors. Hot water shall be used to produce low pressure saturated steam which in turn, shall be used in Multi-Effect Desalination system to produce desalinated water from sea water. c. PLANT INPUT & OUTPUT DATA S. N o i ii iii Quality of Output Water Quality of Inlet of Seawater Description Unit Parameter Capacity (8 hr Operation) Desalinated Water Tons/D ay 10 TDS ppm 5 Potable Water TDS ppm 150 ph - 6.5-8.5 TDS ppm 33,000-35,000 ph - 8.2 Temperature C 30 4

II. PROCESS DESCRIPTION The solar LTF-MED is designed for a capacity of 10 m3/day and is intended to operate for 8 hours a day. Initially hot water is produced from solar flat plate collectors utilizing solar energy. The inlet water for the solar flat plate collectors is taken from the bottom of the hot water storage tank. The outlet hot water at temperature 65-70 C from solar flat plate collectors is fed at the top of the hot water storage tank. The proposed concept of desalination involves both flashing and evaporation. The vapour is produced by flashing the hot water in the flash chamber from the storage tank and this vapour becomes the heat input to the multi-effect desalination unit to produce steam by evaporating sea water. The pre-heated sea water from the condenser is sprayed onto the tube bundles in the evaporator. The flashed vapour is passed through the tube bundles which condense by exchanging its latent heat with the falling sea water. Thus vapour is produced outside the tubes due to evaporation and this vapour enters the second effect of the evaporator. This vapour produced in the first effect is in turn condensed in the second effect, again evaporating a portion of the seawater feed. This process is repeated up to the fourth effect. The fourth effect vapour is condensed in a condenser by transferring latent heat to the incoming seawater. The heated raw seawater coming from the condenser becomes feed water to the evaporators. Pressure difference between the effects is maintained by orifice/ venturi meter on the vapour side and barometric head on the liquid side. The distillate produced and remaining brine in each effect is transferred to the successive effects and finally pumped out by distillate and brine pumps respectively. The brine is partially re-circulated to the process as feed water and the remaining is rejected by proper seawater drain system to the sea. The distillate from the condenser is re-mineralised for drinking purpose as per World Health Organisation (WHO) standards and stored in a storage tank. Typical process diagram of the system is mentioned in the pdf file. This plant is a standalone system, the electrical power required to drive the pump and accessories of the plant is harnessed by using Solar Photo Voltaic System. Schematic layout of the plant is shown in the Fig.1. 5

Fig.1 Schematic Layout of the MED plant at site 6

A. MULTI-EFFECT DESALINATION(MED) SYSTEM 1. SCOPE OF WORK The Scope of Work includes Design, Fabrication, Manufacturing, Supply, Installation, and Testing & Commissioning of Evaporators, Flash Chamber, Condenser and sub systems at Vivekananda Kendra, Kanyakumari district of Tamil Nadu. Submission of all fabrication drawings of the installed system. Submission of training and maintenance documents. 2. SCOPE OF SUPPLY Scope of supply includes all manufactured items like Flash chamber, evaporator, condenser and piping, instruments etc., as required. 3. MAIN COMPONENTS OF MED UNIT The major plant components/equipments comprise mainly the following S. N o Main Components / Equipments Unit Quantity 1. Flash Chamber No. 1 2. Evaporator No. 1 3. Condenser No. 1 4. Vacuum Systems No. 1 5. Piping and Instruments Lot 1 3.1. FLASH CHAMBER The hot water from the solar thermal collectors enters the flash chamber which is at a pressure lower than the saturated vapor pressure of the hot water. A portion of the hot water vaporizes and the water cools by giving away the heat for vaporization. The decrease in temperature after flashing is compensated by the heat source. 7

3.2. EVAPORATOR The evaporator is a simple shell and tube heat exchanger where the vapour from the flash chamber is fed into the tubes and the saline water is sprayed over the tubes. The sprayed seawater is heated and evaporation begins when the temperature corresponding to saturation pressure maintained in the evaporator is reached. The vapour production in the effect is slightly lesser than the quantity of vapour produced in the flash chamber. The quantity of spraying is based on the experience and optimization of scaling factor. The heat transfer tubes used are of aluminum alloy and fixed using Ethylene Propylene Diene Monomer (EPDM) rubber grommets Food Grade (FG) for simple and easy maintenance. The vapour generated in the last effect of the evaporator is condensed in a condenser. The evaporator consists of four effects. Each effect will be individual with interconnecting pipes. As all the effects are operating at vacuum conditions reinforcements and stiffeners should be provided on the evaporator shell in order to endure the load during pneumatic tests and during operation. The evaporator shells of all effects should be made of Duplex Steel Material. The bottom of each effect should be provided with a manhole for maintenance and inspection. The Manhole covers on evaporator shell should be hinged for easy opening and should be accessible from platforms and ladders around the unit. The cover should be kept in easily accessible locations. Observation windows/ sight glass with lighting should be provided in each effect to observe spray pattern inside the shell. The seawater feed spray nozzles shall be constructed of SS 316L material and will be designed for ease of removal in case of blockage. The nozzle design and their location on distribution header should ensure uniform flow distribution over the tube bundles to avoid areas of low flow or drying out and consequential scale formation on the tube surfaces. Demisters required for maintaining purity of the product water should be made by SS 316 L mesh mats with minimum 75mm thickness. They shall be arranged in conveniently sized inter changeable sections to permit ease of handling, maintenance, and replacement through access door. Access platform, walkways, handrails, and 8

access stairs shall be permanently installed for access to all important sections of the plant for maintenance and inspection wherever necessary. The design shall be in accordance with ASME / HEI / TEMA standard. 3.3. EVAPORATOR TUBE BUNDLE The evaporator tube bundles shall be as per TEMA standards or design approved by the engineer user's department. The tube bundle in each effect shall be horizontal and fixed to Duplex tube plates by grommet. Mock testing of rubber grommets for arriving at the leak rate should be conducted before installation in the evaporators. Such testing will be witnessed by engineers from user department. Suitable support plates of compatible material are to be provided. Provisions for easy removal and replacement of tubes through bolted and manhole covers without any cutting should be planned. Evaporator tube shall be of Al alloy. Suitable fouling factors should be considered in the design of the heat transfer surface in the MED plant. Some of the tubes shall be used for cooling the non condensable gases. All interconnecting ducts and pipe work should have sufficient flexibility to allow thermal expansion without imposing excessive loading on associated plant equipments and pumps. Flexible bellow / couplings should be used wherever applicable and shall be designed to withstand both pressure and vacuum condition. Tubes inside the shell can be arranged either in central tube or side tube arrangement. The actual tube arrangement can be chosen depending upon the ease of fabrication, accessibility of tubes and demisters and manhole placing. Mechanical design should be based on the arrangement chosen. For similarity all the effects shall be of same dimension and arrangement. The detailed engineering drawings of all the evaporators and equipments with all the dimensions are to be made by the supplier. The drawings are to be approved by the user s executive engineer before taking up for the fabrication job by the supplier. Tentative dimensions & specifications of evaporator shell and tube bundle (Al alloy) are given in Technical specifications. Each evaporator should have adequate heat exchanging surfaces. The requested heat surface shall be accommodated in shells with required diameter and total length not exceeding the comfortable access to the tube sheets. In this size, comfortable 9

access to the internals should be considered for inspection and maintenance. 3.4. INTERCONNECTION BETWEEN STAGES All effects will be placed in a common shell. Vapour in the every effect should be transferred to the next effect through vapour box. Condensate collected at the end of tube bundle is transferred to the successive effects via U pipe. Concentrated seawater (brine) is also transferred to the successive effects via U pipe. 3.5. CONDENSER Condenser is a simple heat exchanger with condensing steam on the shell side and cooling seawater on the tube side. The condenser is made of stainless steel shell and titanium tubes fixed with tube expansion. The cooling water enters the tubes of the condenser and the exit water is split into two streams one feeding the evaporator and the other is rejected back to the sea. The total product water is collected out from the condenser as distillate. Tubes for condenser will be of Ti Gr.2 with required wall thickness as per the process. The water boxes, tube plates and tube support plates shall made of Duplex. Shell shall be made of Duplex. The design of condenser should be done in accordance of TEMA C. Galvanic coupling between dissimilar metal should be avoided. The tube side design flow rate of seawater should be in line with the process requirement. Shell side condensing vapor design load should compensate the working condition. Condenser coolant sea water flow rate should be designed as per the process requirement. The condenser should have an adequate heat exchanging surface and size of tubes corresponds to the same. The number of passes shall be as necessary to ensure the acceptable process water flow velocity. 3.6. VACUUM SYSTEM A single stage water jet ejector forms the vacuum system for the entire system. This shall be capable of extracting all the non-condensable gases (NCG) from feed water, air in-leakage and carbon dioxide released in evaporation, together with associated vapour and discharging to atmosphere. Non-condensable gases will be transferred by cascade venting to the lowest pressure part (up to the condenser) and then extracted by the 10

ejector. The ejector is driven by seawater at required pressure which is the motive water flow for the ejectors and the NCG are sucked through the ejector secondary stream and discharged along with reject. 3.7. PIPING / INSTRUMENTS Supply of necessary pipes and valves and laying them are under the scope of the supplier. Suitable sensors insertion points are to be kept on the piping for sensing the required parameters like flow, pressure and temperature. Suitable valves are to be provided wherever needed. Suitable Non Return Valves are to be provided wherever necessary. Adequate flanged connections shall be provided for hot water inlet and outlet piping from solar water heating system, sea water intake and drain piping and distillate pumping system. 4. INSPECTION / TESTING / ACCEPTANCE TESTS i. IIT reserves the right to inspect, or to have their authorized representative inspect the Solar LTF-MED at any time during their fabrication to ensure their compliance with the specification. ii. iii. The supplier shall conduct the following tests at the factory. Visual Inspection Overall dimensional inspection Leak test Pressure test Weight of each piece of the equipment The necessary tapping to be provided on the tube side as well as on the shell side for fixing gauges (Pressure, Temperature and Flow). 5. DRAWINGS & DOCUMENTS The following Set of documents shall be supplied along with equipment: Bought out items Data Sheet Raw material test certificate for metallic components (shell, dish ends, tubes, tube sheets, baffle plates etc) under section 3 11

Factory Acceptance Test Certificate Operation / Maintenance Manual Parts Catalog. As-Built Drawings for the entire Assembly and non-assembly procedure. Handling procedure. 6. PERFORMANCE GUARANTEE The Solar LTF-MED shall be guaranteed for material, workmanship and satisfactory performance at site, online for a minimum period of Twelve (12) months from the date of commissioning. 7. OVERALL PROCESS SPECIFICATION S.NO OVERALL DESIGN PARAMETERS UNIT DATA 1 Plant Capacity / Production m 3 /day 10 2 Operating Hours / Day hrs. 8 3 Gain Output Ratio (GOR) 3.5 (min) 4 No. Effects (Minimum) nos. 4 5 First effect temperature C 55.4 6 Last effect temperature C 46.7 7 Sea water flow rate to Condenser kg/h 27,000 8 Sea water inlet temperature C 25 to 30 9 Feed Seawater spray flow rate in each effect kg/h 6,800 10 Feed sea water temperature C 32 11 Product Salinity (TDS) ppm 5 12 Sea water Salinity ppm 33,000 35,000 13 Brine Discharge Flow Rate kg/h 1800 Note: All the technical parameters are indicative value, Bidder has to design and specify in their offer. 12

8. TECHNICAL SPECIFICATIONS S. NO DESCRIPTION REMARKS A FLASH CHAMBER 1 Material of Construction SS 316L 2 Design Pressure Vacuum 3 Design Temperature 65 C 1400 (minimum) x 4 Shell Size (mm) OD x Thick x Length x B 1 EVAPORATOR Material of Construction (Sea Water side/ Steam side ) Duplex / SS 316L 2 Design Pressure Vacuum 3 Design Temperature 55.4 C 1400 (minimum) x 4 Shell Size (mm) OD x Thk x Length x 5 Tube Material Aluminum Alloy 6 Tube Size (mm) OD x Thk x Length For 1 Effect 25.4 x x 1400(minimum) 7 No. of Effects (minimum) 4 nos. 8 Tube to Tube Sheet Connection Grommet 9 Grommet Material / Size EPDM (F.G) / 10 Tube arrangements Triangular Pitch 11 Heat transfer area in m 2 380 12 Sight glass with lighting 4 nos - Bidder to specify in their offer Note: All the technical parameters are indicative value, Bidder has to design and specify in their offer. 13

C 1 CONDENSER Material of Construction (Sea Water side/ Steam side ) Duplex/ SS 316 L 2 Design Pressure Vacuum 0.09 bar(a) 3 Design Temperature 4 Size (mm) ID x Thk x Length 800 (min) x x 1800 (min) 5 Tube Material Ti Grade 2 6 Heat Transfer Area 90 m 2 7 Tube Size (mm) OD x Thk x Length 17.4 x x 1400 (min) 8 Type of Pass Double Pass 9 Tube to Tube Sheet Connection Expansion 10 Tube arrangement Triangular Pitch D Mounting structures Suitable mounting structures made of GI metallic frames shall be provided for MED and its subsystems to ensure proper positive suction head for the distillate pump. All the interconnecting pipes and valves shall be provided as per IBR standards. E Piping and Instruments Suitable sensor insertion points shall be provided for sensing the parameters (Flow, temperature, pressure). Adequate flanged connections shall be provided for facilitating the process piping as specified in section 5.5. - Bidder to specify in their offer Note: All the technical parameters are indicative value, Bidder has to design and specify in their offer. 14

9. EXPERIENCE OF THE BIDDER The bidder should have designed/engineered, manufactured/ erected and commissioned at least one multi-effect distillation coupled with 5 TPH steam generation system. 10. TECHNICAL DATA-SHEETS BIDDER TO FILL S. NO DESCRIPTION REMARKS A FLASH CHAMBER 1 Material of Construction SS 316L 2 Design Pressure 3 Design Temperature 4 B Shell Size (mm) OD x Thick x Length EVAPORATOR x x 1 Material of Construction (Sea Water side/ Steam side ) Duplex/ SS 316 L 2 Design Pressure 3 Design Temperature 4 Shell Size (mm) OD x Thk x Length x x 5 Tube Material Aluminum Alloy 6 No. of Tubes 7 Tube Size (mm) OD x Thk x Length For 1 Effect x x 8 No. of Effects (minimum) no 9 Tube to Tube Sheet Connection Grommet 10 Grommet Material / Size EPDM (F.G) / 11 Tube arrangements Triangular Pitch 12 Heat transfer area in Sq. m - Bidder to specify in their offer 15

C CONDENSER 1 Material of Construction (Sea Water side/ Steam side ) Duplex/ SS 316 L 2 Design Pressure 3 Design Temperature 4 Size (mm) ID x Thk x Length x x 5 Tube Material Ti Grade 2 6 Heat Transfer Area 7 No. of Tubes 8 Tube Size (mm) OD x Thk x Length x x 9 Type of Pass Double Pass 1 0 Tube to Tube Sheet Connection Expansion 1 1 Tube arrangement Triangular Pitch D Mounting structures E Piping and Instruments - Bidder to specify in their offer 16

B. SOLAR WATER HEATING SYSTEM 1. SCOPE OF WORK The Scope of Work includes Design, Supply, Installation, Testing & Commissioning of Solar flat plate collector water heating system with adequate storage at Vivekananda Kendra, Kanyakumari district of Tamil Nadu. Submission of training and maintenance documents. Submission of all details of the installed systems like component details and manuals, test reports, etc. 2. SCOPE OF SUPPLY Scope of supply includes supply of all the Flat plate collectors, Thermal energy storage, support structures, piping and instruments, recirculation pump, as per the applicable standards given in the subsequent section. 3. SOLAR WATER HEATING SYSTEM The plant being driven by thermal energy, the design/capacity of the entire plant is dictated by the availability of solar heat as hot water from solar panels in the day hours. The advantage of the technology is mainly from the use of renewable energy. Motive steam for the MED System is flashed from the hot water in the Flash chamber under Vacuum condition. This hot water is produced from the solar flat plate collectors utilizing the solar energy. The initial inlet water for solar collector is from a DM Tank. Once the system starts circulation the water is circulated continuously between solar thermal collectors and flash chamber. The required flashing temperature of 62 ºC for flash chamber is attained in the solar thermal collectors and there will be a temperature drop in the flash chamber. This water at lower temperature of 55 ºC is again circulated to solar thermal collectors for raise in temperature. The approximate flash range will be from 55 ºC to 62 ºC 17

3.1. PROCESS PARAMETERS S. NO DESCRIPTION 1. System Capacity 2. Plant operating hours 8 hours / day SPECIFICATIONS 30.6 TPH @ solar insolation of 800 W/m 2 3. Working fluid Distilled Water (<10 ppm) 4. Inlet Temperature 55 deg C 5. Inlet Pressure 2.9 bar 6. Outlet Temperature 62 deg C 7. Outlet Pressure 2.5 bar 4. MAJOR COMPONENTS OF SOLAR WATER HEATING SYSTEM The major components of the solar water heating system comprise the following S. NO DESCRIPTION A. Flat plate collectors B. Thermal energy storage C. Recirculation pump D. Mounting / Support structures E. Piping and Instruments 5. INSPECTION / TESTING / ACCEPTANCE TESTS IIT reserves the right to inspect and /or to test the goods to confirm their quality in compliance with the specification. 18

6. DRAWINGS & DOCUMENTS The following set of documents shall be supplied along with equipment: Bought out items Data Sheets and Test certificates Operation manuals with drawing, parts list (with part codes) P&I drawings with list ratings of components and list of do s and don ts for the main equipment as well as the subsystems As-built drawing of the solar water heating system 7. STANDARDS The goods supplied and works executed shall confirm to the standards mentioned in the technical specification and where no applicable standard is mentioned, the latest version of Indian Standard Institution or Bureau of Indian Specification shall be applicable. 8. PERFORMANCE GUARANTEE The Solar water heating system shall be guaranteed for material, workmanship and satisfactory performance at site, on line for a minimum period of Twelve (12) months from the date of commissioning. 9. TECHNICAL SPECIFICATIONS S. NO 1. 2. 3. DESCRIPTION Type of solar thermal collectors System capacity @ 800 W/m 2 Collector dimensions (Length Height Width) 19 SPECIFICATIONS Flat plate collector 30.6 TPH 4. Absorber area 1.8 m 2 1860 mm (minimum) 5. Absorber material Copper sheet and copper tubes 6. Absorber coating Selectively Coated Continuous

Electroplating of Black Chrome over Nickel substrate Absorptivity >95%, Emissivity < 18% 7. Fin & Tube Bonding Brazing/Welding 8. Header & Raiser Bonding Brazing/Welding 9. Collector Box 10. Cover plate 11. Insulation 12. Reflector 13. Gaskets and Grommets material Collector box shall be made of Aluminium section only Single piece tempered / toughened glass of minimum thickness 4 mm. The solar transmission of the cover plate shall be >82% at near normal incidence Insulation of rock wool/ glass wool/ mineral wool of suitable thickness shall be provided at back and sides of the absorber. Aluminium foil of thickness >0.1 mm shall be provided Neoprene / High quality EPDM 14. Flanges SS 304, Class 150 15. Mounting structures Galvanized iron or mild steel support structures to withstand wind load. Provide suitable grouting for installation on the ground 16. Piping Piping as per IBR standards 16. Insulation for piping 17. Thermal Energy storage 18. Recirculation pump Insulation of rock wool/ glass wool/ mineral wool of suitable thickness shall be provided with Aluminium cladding for hot water lines. Suitable thermal energy storage shall be provided for continuous hot water supply 1 no. as per specification given below. 20

S.no Description Recirculation pump 1 General Make Grundfos / equivalent Type Centrifugal Duty (%) 110 Suction pressure [bar(a)] 0.16 Discharge pressure [bar(a)] 6 2 Process parameters Fluid Distilled water Flow (m 3 /h) 30.6 Temperature ( c) 55-62 3 Material of construction Casing Ss 316l Impeller Ss 316l 4 Motor Rated power (kw) 7.5 Duty (%) 110 Variable frequency drive Abb/equivalent - Bidder to specify in their offer Note: All the technical parameters are indicative value, Bidder has to design and specify in their offer. below: All the components must confirm BIS Standards and IBR standards as specified The Flat plate collector and its components must confirm BIS Standard IS12933 Piping as per relevant IBR standards 10. EXPERIENCE OF THE BIDDER MNRE/TEDA Approved Manufacturers/Suppliers/System Integrators with minimum 2 years of experience in the field of solar water heating with at least one successfully installed industrial water heating project. 21

11. TECHNICAL DATA-SHEETS BIDDER TO FILL - Bidder to specify in their offer S. NO 1. 2. 3. DESCRIPTION Type of solar thermal collectors System capacity @ 800 W/m 2 Collector dimensions (Length Height Width) 4. Absorber area 5. Absorber material 6. Absorber coating 7. Fin & Tube Bonding 8. Header & Raiser Bonding 9. Collector Box 10. Cover plate 11. Insulation 12. Reflector 13. 14. Flanges Gaskets and Grommets material 15. Mounting structures 16. Piping 16. Insulation for piping 17. Thermal Energy storage 18. Recirculation pump SPECIFICATIONS Flat plate collector 30.6 TPH / 250 kw th 22

C. 15 kwp OFF-GRID GROUND MOUNTED SOLAR PHOTOVOLTAIC (PV) SYSTEM 1. SCOPE OF WORK The Scope of Work includes Design, Supply, Installation, Testing &Commissioning of Solar PV Power Plant of 15 kwp Capacity with adequate storage at Vivekananda Kendra, Kanyakumari district of Tamil Nadu. Submission of training and maintenance documents. Submission of all details of the installed systems like component details and manuals, test reports, etc. 2. SCOPE OF SUPPLY Scope of supply includes supply of all the PV modules, Power conditioning unit, Battery banks, support structures, DC Junction boxes, DC and AC distribution boxes, grounding systems, as per the applicable standards given in the subsequent section. 3. SOLAR PV POWER GENERATION SYSTEM As the plant is operated in a standalone mode, the total power required for the plant is harnessed by using Solar Photo Voltaic System. The major power consumption of the plant is for Pumps and I&C Items. The maximum Power requirement will be 15 kwp 4. MAJOR COMPONENTS OF SOLAR PV POWER GENERATION SYSTEM The major components of the solar PV power generation system comprise the following S. NO DESCRIPTION A. Solar PV array B. Battery bank C. Power conditioning unit D Cables E Junction Box/Combiners 23

F G H F Module Mounting structure DC distribution board (DCDB) AC distribution board (ACDB) Earthing system 5. INSPECTION / TESTING / ACCEPTANCE TESTS IIT reserves the right to inspect and /or to test, the goods to confirm their quality in compliance with the specification. 6. DRAWINGS & DOCUMENTS The following Set of documents shall be supplied along with equipment: Bought out items Data Sheets and Test certificates Operation manuals with drawing, parts list (with part codes) circuit diagrams with list ratings of components and list of do s and don ts for the main equipment as well as the subsystems Maintenance manuals 7. STANDARDS The goods supplied and works executed shall confirm to the standards mentioned in the technical specification and where no applicable standard is mentioned, the latest version of Indian Standard Institution or Bureau of Indian Specification shall be applicable. 8. PERFORMANCE GUARANTEE The Solar PV system shall be guaranteed for material, workmanship and satisfactory performance at site, online for a minimum period of Twelve (12) months from the date of commissioning. 24

9. TECHNICAL SPECIFICATIONS S. NO DESCRIPTION SPECIFICATIONS A. Solar PV array capacity 15 kwp 1. Type of PV module Poly Crystalline 2. No. of modules 75 3. Module rating 200 Watts 4. Module efficiency 14% 5. Open circuit voltage 44.78 V 6. Short circuit current 5.78 A 7. Vmax 37.67 V 8. Imax 5.31 A 9. No. of cells 72 10. Module dimensions 1323 mm 982 mm 36 mm B. Battery bank Battery backup for 1 hour 1. Battery rating 24 V, 150 Ah 2. Type of battery Lead acid tubular battery 3. No. of batteries C. Power conditioning unit Minimum 18.75 kva Nominal output 1. Inverter output voltage 3 phase 415 Volts 2. Inverter output frequency 50 Hz 3. Inverter efficiency >80% 4. Waveform Pure sine wave D Cables Cables running between solar panels and array junction box should be 4 Sq mm copper flexible. Power cables of adequate voltage and current insulation rating shall be used. Cable trays shall be provided as per requirement. E Junction Box/Combiners Dust and water proof junction boxes of 25

F G H Module Mounting structure DC distribution board (DCDB) AC distribution board (ACDB) adequate rating and adequate terminal facility made of fire resistant plastic (FRP) shall be provided. Modules shall be mounted on a noncorrosive support structures towards due south and at a suitable inclination to maximize annual energy output. Suitable grouting shall be provided for installing over the ground. It shall be provided in between PCU and Solar Array. It shall control the AC power from PCU, and should have necessary surge arrestors - Bidder to specify in their offer Note: All the technical parameters are indicative value, Bidder has to design and specify in their offer. All the components must conform to the latest edition of IEC/ Equivalent BIS Standards/ MNRE specifications as specified below: The PV modules must confirm IEC / BIS equivalent IS Standards IEC 61215 / IS14286 PCUs must comply with IEC 61683/IS61683 or equivalent BIS standards Batteries as per relevant BIS standards Cables IEC 60227 / IS 694 Junction boxes, charge controllers IP 54(for outdoor) 10. EXPERIENCE OF THE BIDDER MNRE approved or TEDA Approved manufacturer/supplier/system integrator with at least 2 years of experience in Solar Photovoltaic (PV) field. 26

11. TECHNICAL DATA-SHEETS BIDDER TO FILL - Bidder to specify in their offer S. NO DESCRIPTION SPECIFICATIONS A. Solar PV array capacity 15 kwp 1. Type of PV module 2. No. of modules 3. Module rating 4. Module efficiency 5. Open circuit voltage 6. Short circuit current 7. Vmax 8. Imax 9. No. of cells 10. Module dimensions B. Battery bank Battery backup for minutes 1. Battery rating 2. Type of battery 3. No. of batteries C. Power conditioning unit Minimum 18.75 kva Nominal output 1. Inverter output voltage 415 V 2. Inverter output frequency 50 HZ 3. Inverter efficiency 4. Waveform D Cables E Junction Box/Combiners F Module Mounting structure G DC distribution board (DCDB) H AC distribution board (ACDB) 27

D. SEA WATER INTAKE AND DRAIN SYSTEM, DISTILLATE RE-MINERALIZATION UNIT & INTEGRATION OF PLANT SUBSYSTEMS 1. SCOPE OF WORK The Scope of Work includes Design, Engineering, Supply, Construction, Erection & Commissioning of sea water intake and drain systems, distillate re-mineralization unit at Vivekananda Kendra, Kanyakumari district of Tamil Nadu. Construction of new bore well / open well / utilizing existing well at the site for continuous supply of 27 TPH of sea water. Integration of various components of the plant with necessary piping and instruments. Submission of training and maintenance documents. Submission of all details of the installed systems like component details and manuals, test reports, etc. 2. SCOPE OF SUPPLY Scope of supply includes supply of Sea water pump, Brine pump, Distillate pump, Re-mineralization plant, Distillate storage tank, Sea water intake and drain sub system, piping and instruments as per the technical specifications and applicable standards given in the subsequent section. 3. OVERALL PROCESS PARAMETERS S. NO OVERALL DESIGN PARAMETERS UNIT DATA 1 Plant Capacity / Production m 3 /day 10 2 Operating Hours / Day hrs. 8 3 Gain Output Ratio (GOR) 3.5 (min) 28

4 No. Effects (Minimum) nos. 4 5 Fist effect temperature C 55.4 6 Last effect temperature C 46.7 7 Sea water flow rate to Condenser kg/h 27,000 8 Sea water inlet temperature C 25 to 30 9 Feed Seawater spray flow rate in each effect kg/h 6,800 10 Feed sea water temperature C 32 11 Product Salinity (TDS) ppm 5 12 Sea water Salinity ppm 33,000 35,000 13 Brine Discharge Flow Rate kg/h 1800 4. INSPECTION / TESTING / ACCEPTANCE TESTS I. IIT reserves the right to inspect, or to have their authorized representative inspect the project at any time during their construction, erection and commissioning to ensure their compliance with the specification. II. The necessary tapping to be provided on piping and tanks for fixing gauges (Pressure, Temperature and Flow). 5. DRAWINGS & DOCUMENTS The following set of documents shall be supplied along with the equipments: Bought out items Data Sheets and Test certificates Raw material test certificate for metallic components As- built drawings Handling procedures 6. STANDARDS The goods supplied and works executed shall confirm to the standards mentioned in the technical specification. 29

7. PERFORMANCE GUARANTEE The system shall be guaranteed for material, workmanship and satisfactory performance at site, online for a minimum period of Twelve (12) months from the date of commissioning. 8. TECHNICAL SPECIFICATIONS S. NO DESCRIPTION SPECIFICATIONS A. SEA WATER INTAKE SYSTEM 1. Construction of new bore well / open well or utilizing existing well at the site for continuous supply of 27 TPH of sea water at 25-30 deg C. 2. Seawater pump 1 no. * 3. Water pretreatment B. SEA WATER DRAIN SYSTEM Multimedia filter and Pre-chlorination system The Brine reject of 1.8 TPH shall be pumped by brine pump to the disposal 1. point embedded in the sea shore. From there the reject brine will be dispersed in to the sea water. 2. Brine Pump 1 no. * C. DISTILLATE RE-MINERALIZATION UNIT 1. Distillate storage tank capacity 20000 Litres (minimum) 2. Material of construction Fiberglass Reinforced Plastics (Food grade) 3. Distillate Pump 1 no. * 4. Soda Ash for ph Dosing System As per requirement 5. Dosing pumps As per requirement D. Piping As per requirement E Civil works As per requirement * - Detailed specification of the pumps is given in the table PUMP SPECIFICATIONS - Bidder to specify in their offer Note: All the technical parameters are indicative value, Bidder has to design and specify in their offer. 30

PUMP SPECIFICATIONS S.No DESCRIPTION SEA WATER PUMP BRINE PUMP DISTILLATE PUMP 1 GENERAL MAKE Grundfos / Grundfos / Grundfos / Equivalent Equivalent Equivalent TYPE Centrifugal Centrifugal Centrifugal DUTY (%) 110 110 110 SUCTION PRESSURE [bar(a)] 0.40 0.30 0.30 DISCHARGE PRESSURE [bar(a)] 2.5 3 3 2 PROCESS PARAMETERS FLUID Sea water Sea water Distilled water FLOW (m 3 /h) 27 5.5 1.6 TEMPERATURE ( C) 30-35 44-46 43 3 MATERIAL OF CONSTRUCTION CASING SS 316L SS 316L SS 316L IMPELLER SS 316L SS 316L SS 316L 4 MOTOR RATED POWER (kw) 4 1.1 0.55 DUTY (%) 110 110 110 VARIABLE FREQUENCY DRIVE ABB/Equivalent ABB/Equivalent ABB/Equivalent 9. EXPERIENCE OF THE BIDDER The bidder should have minimum 3 years experience in the field and must have designed / engineered, manufactured / erected and commissioned conveyance pipelines and construction of water treatment plants of minimum capacity 15m 3/ day 31

10. TECHNICAL DATA-SHEETS BIDDER TO FILL S. NO DESCRIPTION SPECIFICATIONS A. SEA WATER INTAKE SYSTEM 1. 2. Seawater pump 3. Water pretreatment B. SEA WATER DRAIN SYSTEM The Brine reject of 1.8 TPH shall be collected in a tank of suitable capacity 1. that is embedded near the disposal point in the sea shore. The reject water will be pumped to this tank for percolation in to the sea water. 2. Brine Pump 3. Brine reject storage tank C. DISTILLATE RE-MINERALIZATION UNIT 1. Distillate storage tank capacity and quantity 2. Material of construction 3. Distillate Pump 4. Soda Ash for ph Dosing System 5. Dosing pumps D. Piping E Civil works - Bidder to specify in their offer 32

S.No DESCRIPTION SEA WATER PUMP BRINE PUMP DISTILLATE PUMP 1 GENERAL MAKE TYPE Centrifugal Centrifugal Centrifugal DUTY (%) 110 110 110 SUCTION PRESSURE [bar(a)] DISCHARGE PRESSURE [bar(a)] 2 PROCESS PARAMETERS FLUID Sea water Sea water Distilled water FLOW (CuM/h) 27 5.5 1.6 TEMPERATURE ( C) 30-35 44-46 43 3 MATERIAL OF CONSTRUCTION CASING SS 316L SS 316L SS 316L IMPELLER SS 316L SS 316L SS 316L 4 MOTOR RATED POWER (kw) DUTY (%) VARIABLE FREQUENCY DRIVE - Bidder to specify in their offer 33