Frequently Asked Questions. Neuraxial Connectors (ISO ) October 19, 2016 (v2)

Similar documents
This document is a preview generated by EVS

To: Commissioners of Prefectural/Cities with Established Health Centers/Special District Health Department (Bureau)

ICAHN Targeted Focus Area: Medication Devices and Technology

Your Complete Outsourcing Partner EXPERTISE TO TURN YOUR IDEAS INTO REALITY

Advancing the Delivery of Home Infusion Therapy curlinpump.com

with Nemera s extensive experience in developing and manufacturing parenteral drug delivery devices

The Device Side of Combination Products

DIFFERENTIATION WITHOUT DISRUPTION

Drug Products, Labeling, and Packaging

ChemoClave System Oncology Kits and Multi-Packs

Contents. Introduction

TECHNICAL DATA SHEET BD Emerald Syringe with and without needle Sterile, Single Use, Latex free

Value Plastics, inc. SPECIALISTS IN FLUID CONNECTIONS

Venue. Ultrasound for the critical moment. Simple. Fast. Precise. gehealthcare.com

PROPOSED DOCUMENT. Global Harmonization Task Force. Title: Reportable Events During Pre-Market Clinical Investigations

Streamlined Blow-Fill-Seal Insertion Technology Increases Flexibility and Safety in Aseptic Packaging of Pharmaceutical Liquids

CASE STUDY Recalled Blood Monitoring Medical Device

SECTION: PATIENT CARE Number:

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB

Part 4: Prefilled syringes

How are GS1 and IHTSDO standards working together?

New product code functionality starting Multiple product codes for each article number

FDA s Bar Code Label Requirements for Human Drug Products. General Questions Related to Drugs and Biologics

BRITISH GENERIC MANUFACTURERS ASSOCIATION

Teleflex Incorporated (NYSE: TFX) Investor Presentation

510(k) Summary. 510(k) Number: K Summary Prepared: August 31, 2017

FDA PLANS TO REGULATE TESTS AS DEVICES. August 2010 SPECIAL REPRINT. By Ellen Flannery and Scott Danzis

Automated compounding for intravenous chemotherapy

March 4, Dockets Management Branch (HFA-305) Food and Drug Administration 5630 Fishers Lane, Rm Rockville, MD 20852

Solutions for All Your Aseptic Parenteral Drug Formulation/Filling Needs. BUBBLE-FREE FILLING : A New Option in Prefilled Syringe Filling

Safe Medication. Disposable Syringes

Supply of aseptically - prepared doses of IMPs across legal boundaries. Edition 1. December 2017

CADTH COMMON DRUG REVIEW. Procedure for the CADTH Common Drug Review

Easy EHR Issue Reporting Challenge. June 7, 2018

CANADA (HEALTH CANADA)

SAN TM PRODUCT FAMILY SAFE AUTO-NEEDLES TM. Better injectors. Better compliance. Better care.

Guideline on the label design for Injections (Draft for Comments)

Cardinal Health overview and strategic priorities

This document is a preview generated by EVS

Leading Pharmacy Benefits Manager (PBM) Implements ProcurePort esourcing to Efficiently Source Prescription Drugs

Manufacturers. Factsheet for. of Medical Devices. Medical Devices Regulation (MDR) background. Act now to be ready on time!

Technologies to Prevent Medication Errors in Hospitals

-- Study achieved statistical significance on all primary and secondary biological endpoints --

Management. National Standards Authority of Ireland

ENABLE INJECTIONS AND FLEX SET AMBITIOUS PLANS FOR LARGE VOLUME DRUG DELIVERY

S P O N S O R E D B Y

THE SARSTEDT GROUP. Your Partner in Medicine. and Science Worldwide

Public Consultation on Annual Review and Proposal for Fees For Financial Year Medical Devices

A New Era of Clinical Diagnostics: How the Business Model is Changing.

Environmental Services Conference

NEW EU Regulations and the EU UDI system

Consulted With; Post/Committee/Group Date Haematology Dr Shereen Elshazly (Lead for Anticoagulation) January 2016 Department of Anaesthesia

Scan4Safety. Implications on Hospital Pharmacy and effect on delivery of healthcare November 2017

Product Catalog (Canada) Conventional Needles I.V. Catheters Micro-Collection Products Safety Products Winged Infusion Sets

Compounding Questions and Answers

BUSINESS OBJECTIVES AND FUTURE PLANS

Business Continuity Management Policy

MEDICAL WASTE MANAGEMENT STUDY NOTES

Anhydrous Ammonia Code of Practice Frequently Asked Questions

Testimony of Molly Ventrelli Vice President, Regulatory Affairs Fresenius Kabi USA, LLC

This document is a preview generated by EVS

Supply Chain Congress 21 August 2013 Megan Main, Chief Executive

USP800: A quick summary and disposal. Brenda Denson, Pharm.D.

Infusion management. Complete administration of the medication without rest volumes

Re: SUPPLY DISRUPTION - Baxter Colleague pump compatible IV administration sets

GS1 Guide on Unique Device Identification (UDI) implementation

GUIDELINES FOR REGISTRATION OF IMPORTERS AND FOR THE IMPORTATION OF MEDICINES AND RELATED PRODUCTS

MEDICINES CONTROL COUNCIL

THE PARTNER FOR INNOVATIVE SOLUTIONS

VALUE WITHOUT COMPARISON DIAGNOSTIC PROCEDURE TRAYS. Quality Without Compromise VALUE WITHOUT COMPARISON

DEMONSTRATING YOUR MEDICINE S VALUE TO ALL STAKEHOLDERS TRUSTED COMMERCIALIZATION AND MARKET ACCESS EXPERTISE

UPS Healthcare Supply Chain Vital Signs

Global Medical Device Nomenclature (GMDN)

Cancer Vanguard. Biosimilars Trust Policy Template

PUTTING PATIENTS FIRST: INNOVATING DRUG CONTAINMENT AND DELIVERY

Anaesthetic and respiratory equipment Tracheostomy tubes and connectors

GUIDE HEA

Medicines Barcoding and Serialization Guideline. National Health Regulatory Authority (NHRA) Kingdom of Bahrain

The Art of Clinical Supply Planning : Quality Product in the Right Place at the Right Time

The future of biologics: reverse engineering for successful product supply

34 th Annual J.P. Morgan Healthcare Conference

U.S. Hospitals Study Executive Summary

REQUEST FOR PROPOSALS SUPPLY OF NEEDLES AND SYRINGES (INCLUDING SOME SPECIALTY PRODUCTS)

Purchasing for Safety Policy for Pharmaceuticals January Page 1 of 8 (Purchasing for Safety Policy for Pharmaceuticals)

INFLATIONARY INDICES JULY 1, DECEMBER 31, 2012

Regulatory Requirements & Recent Changes, including expectations for APIs & IMPs

Manufacturers. Factsheet for. of Medical Devices. Medical Devices Regulation (MDR) background. Act now to be ready on time!

Guide for Class I Manufacturers on Compliance with European Communities (Medical Devices) Regulations, 1994

Product Catalog (US) Conventional Needles I.V. Catheters Micro-Collection Products Safety Products Winged Infusion Sets

Guideline for Theraputic Plasma Exchange

Voluntary Pilot Meeting Preview: How will CDRH apply assessments in the voluntary program?

MEDICINES CONTROL COUNCIL

P E D A L A P P R O A C H

U.S. Food and Drug Administration (FDA) Regulatory Pathways for Medical Devices

Perspective: Convergence of CLIA and FDA Requirements A Rational Shift in the Regulatory Paradigm

Developing a European First-in-Human Study: Three Key Decisions

GS1 Healthcare - Discussion paper on multi-market packs for pharmaceutical products

DRAFTS IN WIDE CIRCULATION DOCUMENT DESPATCH ADVICE MHD 10/ T- 2,3,41,33,43,44,45,46,47,48 10/02/2015 TECHNICAL COMMITTEE: MHD 10

Comfort your patient deserves. Strength you demand.

Healthcare Sector. - Upcoming legislations - GS1 standards. Ann Luyckx Healthcare Manager. Phi Data Event 2018

Transcription:

Frequently Asked Questions Neuraxial Connectors (ISO 80369-6) October 19, 2016 (v2) 1

Frequently Asked Questions Neuraxial Connectors (ISO 80369-6) 1. What is a small-bore connector? 2. What changes are coming to small-bore connectors? 3. Will new neuraxial medical connectors have distinct names? 4. Why is industry adopting the new ISO neuraxial connector? 5. What are the implications of these new standards? 6. What connectors are affected by the ISO 80369-6 (NRFit) connector standard? 7. Which devices are affected by the ISO 80369-6 standard? 8. Who developed the proposed new ISO 80369-6 connector design? 9. Why should we adopt the new 80369-6 connector? 10. What makes the new ISO 80369-6 connector different from the current Luer system? 11. When will the new ISO 80369-6 connector be available? 12. How will the new ISO 80369-6 connector be introduced into my healthcare organization? 13. If we use Neuraxial parts from another manufacturer s set, how will we know the products will work together? 14. Is it mandatory to transition to the new ISO 80369-6 connector? 15. When will the neuraxial devices with current connectors be discontinued? 16. Will there be new item numbers or SKUs for the new 80369-6 sets? 17. If applicable, when will the new item numbers be available and how will we know when to order the new item numbers (SKUs)? 18. Will there be a price increase? 19. Will there be a standard color for the 80369-6 connector? 20. What is the role of StayConnected? 21. Does this new system require that devices using the Luer connector become obsolete? 22. Will there be adapters for different kinds of syringes? 2

1. What is a small-bore connector? A small-bore connector is a connector with an inner diameter of less than 8.5mm used to connect medical devices, components and accessories for the purposes of delivering fluids or gases. 2. What changes are coming to small-bore connectors? The International Organization for Standardization (ISO 1 ) has developed a series of standards for small-bore connectors, known as ISO 80369 series. These standards will provide design and performance specifications for a range of connectors which can be used for different medical device applications (80369-3 enteral ENFit, 80369-6 neuraxial and major regional NRFit, 80369-7 intravascular and hypodermic Luer, etc.) and which will reduce the risks of misconnections between applications. 80369 section Use Common name -2 Breathing systems and driving gases -3 Enteral applications ENFit -4 Urethral and urinary applications -5 Limb cuff inflation -6 Neuraxial applications and major NRFit regional anesthesia -7 intravascular or hypodermic applications Luer 3. Will new neuraxial medical connectors have distinct names? Connector naming is not included in the ISO 80369 series of standards. Therefore, companies are free to name the new connectors as they choose. GEDSA and members of the ISO joint working group have proposed the use of the name NRFit (pronounced ner-fit ) for the new connectors used for neuraxial and major regional applications. NRFit is a name that will be used to identify devices that comply with the ISO 80369-6 standard. 4. Why is industry adopting the new ISO neuraxial connector? The standard small-bore connector in the medical device field for many years has been the Luer connector. Because the Luer connector was such an effective and reliable design, it has been used in many different types of device applications, such as vascular, enteral, respiratory, epidural, and intrathecal. The consequence of this has been misconnection with devices that were not meant to connect, such as the delivery of toxic chemotherapy drugs into the spinal canal. As well as preventing the delivery of IV drugs into the neuraxial space, use of the ISO 80369-6 connectors will also prevent wrong-route delivery of neuraxial medicines (such as bupivacaine) intravenously. 1 ISO (International Organization for Standardization) is the world s largest developer of voluntary International Standards. It has published more than 19,500 International Standards covering 3

5. What are the implications of these new standards? Unique connector designs promote patient safety and helps ensure that connectors for unrelated applications are incompatible. This reduces the chances of wrong route injections, infusions and the harm associated with these incidents. Syringes used for intravascular and hypodermic access will no longer be interchangeable with neuraxial syringes. For manufacturers and suppliers this may/ cause temporary inconvenience as procedure packs may be more difficult to customize. Clinicians need to be aware of what extra items ( drop-ins 2 ) they use, as those will need to be ordered specifically: pulling those from intravenous supplies stock will no longer suffice. Pharmacy departments preparing medicines for intrathecal and epidural use (for example, aseptic preparation of intrathecal chemotherapy preparations) will also have to ensure they have appropriate stocks of syringes, syringe caps, filling devices, filters and other equipment necessary to fill and dispense using the new connectors. 6. What connectors are affected by the ISO 80369-6 (NRFit) connector standard? 80369-6 applications involve the use of medical devices to administer medications to and take samples from neuraxial sites (central nervous system including intracranial and spinal canal such as epidural and intrathecal), major peripheral nerve local anaesthetic blockade and continuous wound infiltration. This includes anaesthetic delivery, monitoring cerebrospinal fluid (CSF) pressure, and removing CSF for therapeutic or diagnostic purposes. 7. Which devices are affected by the ISO 80369-6 standard? Neuraxial devices and devices for major regional anesthesia that currently use Luer connectors will, over the next few years, incorporate the 80369-6 connectors. 8. Who developed the proposed new ISO 80369-6 connector design? This new connector design was developed by ISO through the combined global effort of clinicians, regulators, test houses and industry. The ISO 80369-6 connector has undergone a rigorous validation process including computer aided design (CAD) misconnection tests, laboratory leak testing, human factors and usability assessment. 2 Drop in is a phrase used by industry for devices from other suppliers that are added by clinicians to procedure packs to make a complete kit. 4

9. Why should we adopt the new 80369-6 connector? The ISO 80369-6 connector provides a simple way to reduce the risk of neuraxial misconnections and improve patient safety. The new connector reduces the chance of an unintentional cross-connection with any other connector intended for non-neuraxial routes. In some countries, the legal systems expect clinical staff to take all reasonable steps to mitigate the risk of cross-connection incidents, and therefore may expect clinical staff to use devices that use these application specific connectors. Non-adoption of the new connectors may expose clinical staff and organizations to legal challenges if further wrong-route incidents take place which could have been prevented by use of ISO 80369-6 compliant devices. 10. What makes the new ISO 80369-6 connector different from the current Luer system? The new ISO 80369-6 connector looks like a Luer connector, but is about 20% smaller and has a unique design that reduces the risk of cross connection with other connectors developed under the same series of standards, especially with Luer connectors. There is one visible difference: slip males will have a collar surrounding the connector. 11. When will the new ISO 80369-6 connector be available? Neuraxial devices with the ISO 80369-6 connector are expected to be available starting in the U.S., Canada and other markets in 2017. The ISO 80369-6 connector should be introduced into use with minimal disruption. Timing is subject to change pending regulatory agency clearance and each manufacturer s readiness. Check with your supplier representative for precise timing and device-specific details. 12. How will the new ISO 80369-6 connector be introduced into my healthcare organization? This will vary depending on where you are based. In some countries, it will be under the direction of regulatory authorities and practice experts. In other countries the decision of when to deploy ISO 80369-6 compliant devices may be up to local healthcare organizations or Governments. No matter who is driving the process, healthcare facilities and providers will be able to call upon industry to help them with a careful transition plan to replace Luer devices with the new ISO 80369-6 connector. Although each company may follow their own device and market launch timeline, it is expected that there will be substantial efforts to coordinate the availability of devices in a way that minimizes confusion and logistical problems. To that end, the global industry group has agreed to: Develop and execute a coordinated communications initiative Use a common brand name for the ISO-80369-6 connector NRFit. Use the same time frame to introduce neuraxial devices with the new connector 5

13. If we use Neuraxial parts from another manufacturer s set, how will we know the products will work together? As long as the connectors have been produced in compliance with the ISO standard, then it is expected that the devices will connect together effectively and safely. All major neuraxial device manufacturers are expected to comply with the proposed new ISO standards to help ensure neuraxial components fit together as a system. Many compatible devices will be marked with the NRFit label or with the standard number (ISO 80369-6). For clinician convenience, some items, such as syringe plungers, may be colored yellow. 14. Is it mandatory to transition to the new ISO 80369-6 connector? This varies by jurisdiction. For example, in California all epidural use must be transitioned by January 1, 2017. In the UK, the National Health Service (NHS) has already started planning for the introduction of 80369-6 connectors within 6 months of the California deadline. In Europe and other markets throughout the world, many manufacturers and suppliers are following the subject closely, and plan to adopt the same new global standard connector system. The deployment of devices with the 80369-6 connector may be on different timelines in different global markets, but the goal remains the same to align to a common neuraxial connector across the globe to improve patient safety. 15. When will the neuraxial devices with current connectors be discontinued? Discontinuation of items is at the sole discretion of manufacturers. For precise timing of item discontinuation, contact your supplier representative. The Luer connector for neuraxial devices will be phased out of hospitals on varying timelines. It is important to understand that some devices, such as spinal needles, are presently used for non-neuraxial applications, such as amniocentesis and joint injections. The use of long needles with a Luer connector will still be required after the change to 80369-6 connectors, and some manufacturers have declared their intent to market such devices to meet clinical needs. You should start contacting the suppliers of the needles you presently use and ask them what plans they have for long needles with Luer connectors in the future. If this does not happen, then there is a risk that many common clinical procedures will find themselves in difficulty after the withdrawal of Luer-based spinal needles from the healthcare setting. 16. Will there be new item numbers or SKUs for the new 80369-6 sets? Introduction of new items and related issues such as new item numbers are at the sole discretion of manufacturers. For precise answers relative to new item introductions, contact your supplier representative. In the UK, clinical incidents have already arisen over confusion between proprietary neuraxial connector devices and standard Luer devices, resulting in delays to treatments. It is anticipated that many manufacturers will use product codes that allow individuals to distinguish easily between Luer and ISO 80369-6 devices to avoid such incidents. In countries where proprietary non-luer connectors are already in use the codes will also be different, but there will be need for additional vigilance in these settings. 6

17. If applicable, when will the new item numbers be available and how will we know when to order the new item numbers (SKUs)? Introduction of new items and related issues, such as new item numbers, are at the sole discretion of manufacturers. For precise answers relative to new item introductions, contact your supplier representative. 18. Will there be a price increase? Pricing is at the sole discretion of device manufacturers. 19. Will there be a standard color for the 80369-6 connector? Color-coding is not included in the ISO 80369 series of standards. The standards will only address the shape and size of the new connectors. These engineering controls make it unlikely that two unintended connectors will fit together. While you might see a consistent color used for devices with neuraxial connectors, it is not a requirement. There is, however, a trend in parts of the world to use the color yellow to indicate neuraxial routes. This feature would be provided for convenience, not safety. 20. What is the role of StayConnected? StayConnected is the implementation branch of the Global Enteral Device Supplier Association (GEDSA) which is a federally tax exempt non-profit trade association StayConnected was established in part to help introduce the new ISO standard connectors and facilitate adoption of the new 80369-6 connectors with the healthcare community. GEDSA, which is composed of leading manufacturers and distributors of medical devices, is united by a shared desire to increase patient safety and optimal delivery of neuraxial treatments and procedures. GEDSA speaks with a unified voice to communicate with government agencies, professional associations, healthcare institutions and member suppliers regarding issues that face device manufacturers, suppliers and distributors. GEDSA will lead StayConnected, a joint communication initiative on behalf of the industry to ensure consistency and avoid any confusion as new, safer connectors are introduced in market. 21. Does this new system require that devices using the Luer connector become obsolete? The Luer connector will still be used for intravascular and hypodermic access and now has its own standard in the ISO 80369 series ISO 80369-7. It is, however, expected that availability of neuraxial devices using Luer connectors will decline rapidly because of the significant patient safety benefits associated with a connector which will not cross-connect with Luer. One of the most effective ways to comprehensively reduce the risk of misconnections and enhance patient safety is to ensure that connectors of different delivery systems (i.e., neuraxial and intravascular) are not compatible. 22. Will there be adapters for different kinds of syringes? There will be no adapters for ISO 80369-6 syringes. Syringes will be supplied with the application specific connector. 7

692 N. High St. Suite 304 Columbus, OH 43215 USA gedsa.org Prepared by GEDSA 8