IC-D3160 Ion Chromatograph

Similar documents
Elisa Reader And Washer AT-2960R Washer

FLASH CHROMATOGRAPHY PURIFIER-3004

BOMB Calorimeter. BCal3015 Series EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

Bomb Calorimeter. BCal 3004 Series EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

AUTOCLAVE (VERTICAL) Double Wall ADW-3045 EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES

Bio Safety Cabinet BS EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

Chlorophyll Meter CM-3502 A Lightweight handheld meter for measuring the chlorophyll content of leaves without causing damage to plants.

BOD-3009 INCUBATOR EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

Blood Gas Analyzer-BGA-2100

Everyone can be an Expert. Electrochemical Detector. Autosampler. Complete HPLC-ECD

Thermo Scientific Dionex ICS-900 Ion Chromatography System

HOLMIUM LASER HL-3000

RELIANCE HIGH THROUGHPUT AUTOSAMPLER

Performance characteristics of the 1260 Infinity Quaternary LC system

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

The CDS 7000 E Purge & Trap Concentrator

NanoLC-Ultra system. data sheet. Introducing the NanoLC-Ultra family of high pressure HPLCs for proteomics research

C196-E067A. Prominence UFLCXR. Shimadzu Ultra Fast Liquid Chromatograph

LABTRON.

The Agilent 1260 Infinity BioInert Quaternary Pump. Scope of a low-pressure mixing UHPLC pump with Bio-Inert Capabilities

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Analytical Instrument Qualification According to USP <1058>: Requirements and Examples for the Agilent 1290 Infinity LC System

Engineering Student Technology Committee College of Engineering Colorado State University

ACQUITY Arc TM System

Liquid Chromatography 3000 Series

Performance Characteristics of the Agilent 1220 Infinity Gradient LC system

UFFLC of the Proteome Ultra High Pressure and Ultra Fast Flow Liquid Chromatography: A New Approach To Proteomics

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

Agilent 1260 Infinity Bio-inert Quaternary LC

Agilent MetaCarb 87H Organic Acids Column H + Form User Manual Part No. A5214

ultra why micro-lc? product note introducing the ExpressLC -Ultra system: UHPLC with all the advantages of micro-lc

Maximizing Sample Recovery on the ACCQPrep HP125

TurboMatrix Headspace and Headspace Trap Samplers

Degassed Cation Conductivity

Scale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system

INVITATION FOR QUOTATION. ESE/2015/ Dated: 09/12/2015

easy. HPLC has never been so Agilent 1120 Compact LC Our measure is your success.

Abstract. 1. Introduction

An Automated System for At-Line Process Analysis of Biopharmaceutical Fermentation Reactions

Sub: Tender for HPLC System

Please enclose a item wise compliance report along with the technical bid.

AUTOMATIC PEROXYACETYL NITRATE (PAN) ANALYZER

New Developments in Capillary Ion Chromatography Systems with Electrochemical Detection and Their Applications

Solutions Guide. MX Series II Modular Automation for Nano and Analytical Scale HPLC And Low Pressure Fluid Switching Applications

Advanced Features New Advanced Automation Features Precise Performance Temperature Control Speed Application Flexibility

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive. 2800Si Silica Analyzer Fully automatic calibration Trace sensitivity

Agilent Max-Light Cartridge Cell Information for G4212A and G4212B DAD

Preparative, Pilot & Process Columns

Determination of Inorganic Anions in Acid Rain Using a Dedicated High-Pressure Capillary Ion Chromatography System

Options Eluent Regeneration (RFIC-ER ) Column Heater In-Line Vacuum Degas Full Chromeleon Chromatography Data System

Analyzer Module Wet Chemiluminescence Detection (WCLD)

Markes International Thermal Desorption G8125A, G8126A, G8127A, G8128A, G8131A, G8132A, G8136A, G8133A, MKI-MicroC Site Preparation Checklist

AOC Shimadzu Front End Automation for Gas Chromatography C189-E027E. Environmental. Foods/Beverages/ Consumer Products.

Chem 321 Lecture 23 - Liquid Chromatography 11/19/13

ENVIRONMENTAL ANALYSIS. Solutions for Your Analytical Business Markets and Applications Programs. Solution Note

CTC automated sample injectors for gas chromatography, distributed by Agilent Technologies

Tender Specifications for High Sensitive Triple Quadrupole LCMSMS System

Silica Analyzer. Automated Silica Measurement Dependable and Sensitive

Econo-Pac High Capacity Ion Exchange Cartridges, 5 ml Instruction Manual. Catalog Numbers , ,

Qualification of UPLC system IRequest UPLC Community Tips & tricks Waters Corporation 1

SPECIFICATION. The System shall be easy to use and rugged enough to handle consistently high through performance of the activities.

Quantification of genotoxic "Impurity D" in Atenolol by LC/ESI/MS/MS with Agilent 1200 Series RRLC and 6410B Triple Quadrupole LC/MS

10. Validated Normal Phase HPLC Method for the Determination. Fulvestrant is primarily used in the treatment of hormone receptor

// XPLORER-NS. Full range Total Nitrogen, Total Sulfur instrument for the modern Laboratory.

Physical Stability of a Silica- Based Size Exclusion Column for Antibody Analysis

CX-1 ph Gradient Buffer

PLC Purification Systems

Agilent MetaCarb Ca PLUS Carbohydrate Column Ca ++ Form User Manual Part No. A5205

Optimize Your Process Operations by Improving Process Monitoring

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations

Hichrom Limited 1 The Markham Centre, Station Road, Theale, Reading, Berkshire, RG7 4PE, UK Tel: +44 (0) Fax: +44 (0)

H-Class & H-Class Bio AutoBlend and AutoBlend plus. Jean-Michel Plankeele May Waters Corporation 1

order:

Eliminates troubles with bubbles

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Complete Customer Support

Analytical HPLC solutions

Agilent 1260 Infinity Purification Systems. Infinitely better purity and recovery

Optimizing Purified Sample Recovery on Reverse-Phase HPLC Systems

SYKAM Amino Acid Analyzer

High Throughput Sub-4 Minute Separation of Antibodies using Size Exclusion Chromatography

systemsultimate 3000 for High-Sensitivity Electrochemical Detection

Gold Standard for recovery and purity

IQ/OQ. for DECADE II, Elite, Lite and ROXY , Edition 7, AntecScientific.com T

Simplicity. Accuracy. Durability. Lotix. Automated High Temperature Combustion TOC Analyzer

Automated alternating column regeneration on the Agilent 1290 Infinity LC

How do you maximize purity and yield? 2 Continuous counter-current chromatography

BÜCHI Labortechnik AG

Practical guidance for switching between anion and cation analysis systems

MassPREP On-Line Desalting Cartridge

Cl500/Cl1000 BROCHURE

Paper type solvent filter Cartridge type solvent filter In-line filter. Uniform fiber diameter of 1 µm. Minimized deviation in particle size.

Agilent 1290 Infinity II 2D-LC Solution Biopharmaceutical Polymer Analysis. WCBP Jan 2017 Washington, DC

Hamilton PRP Polymeric Columns

ÄKTAmicro. GE Healthcare. Modular design based on the proven ÄKTA design platform. ÄKTAmicro chromatography system offers:

RC400G FC400G RESIDUAL CHLORINE ANALYZER RC400G NON-REAGENT FREE CHLORINE ANALYZER FC400G RESIDUAL CHLORINE ANALYZER

Seamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC

The Power of Numbers. Zeton Altamira. Zeton Altamira

SAFETY AND QUALITY CONTROL

Transcription:

IC-D3160 Ion Chromatograph IC-D3160 ion chromatograph is a new modular design of the high stability of ion chromatograph, combining Analytical Technologies Limited independent research and development core technology products and foreign excellent machining process equal to one, not only can be configured conductance detector, combined with powerful chromatography workstation and precision circuit control system, the IC-D3160 ion chromatograph can also configure the UV-Vis detector implementating related to environment, food, chemical, geological, and many other areas of conventional anion and cation, sugar, amino acids, other small molecule organic acids, cyanide, etc. 1

Pump Technical Specifications 3113i Quatenary Gradient Pump Wetted Materials: Flow rate: Flow Accuracy: Flow Precision: Pressure Range: Pressure: Pulsation: Compressibility: Compensation: Pressure Ripple: Stainless Steel / PEEK*, Teflon AF PVDF, Ceramics, Sapphire, Ruby Programmable Micro: 0.001-4.000 ml/min Analytical: 0.001-10.000 ml/min Semi-Preparative: 0.1-40.000 ml/min ± 0.08% 1.000 ml / min ± 0.1 % RSD 1.000 ml/min 0 7500 psi Semi-Preparative: 20 MPa (up to 20.000 ml/min); 10 MPa (up to 40.000 ml/min) typical < 0.1 MPa or < 1.0 % user-adjustable for different solvents 396 x 250 x 478 mm <1% without dampner Vacuum Degassing: Gradient Range: Gradiant Accuracy: Gradiant Mixing: Mixing Volume: Composition Precision: 3113i Binary Gradient Pump Vacuum Degassing: Gradient Range: Gradiant Accuracy: Gradiant Mixing: Mixing Volume: optional: < 20% dissolved gases remaining in water @ 1.000 ml/ min 0.0 100.0 %, 4 channels < 0.50 % Active adjustable: 10 500 µl < 0.15% RSD optional: < 20% dissolved gases remaining in water @ 1.000 ml/ min 0.0 100.0 %, 4 channels < 0.50 % Active adjustable: 10 500 µl * depending on configuration 3530i Sample Injector System The Analytical 3530i Sample Injector System is a very flexible and powerful HPLC autosampler with excellent reproducibility and linearity properties. Variable vial racks and adaptors for microliter plates as well as a multitude of firmware options make this system highly adaptable and suitable for any analytical application. Wetted Materials: Stainless Steel / PEEK*, PPS, PVDF Sample tray(thermostatting): 4 o C to 5 o C Ambient Temperature Sample Capacity: 50 x 0.5ml or more Injection Volume: Programmable 0.1-999.9 µl Injection Volume Accuracy: 0.1-100µl Column Length: upto 250 mm along with guard c olumn Column ID: 4 mm Replicate Injection: 1-50 Per vial Sample Heating/Cooling: optional: +4 +60 C Injection Precision: < 0.5 % Variable Volume Injec tion (10 µl; typically ~0.25 %) Linearity: Correlation Factor > 0.999 (10 µl injection volume, 500 µl Syringe) Cross contamination: <0.1% Wash with & without automated needle Wash Dispensing Precision <0.2%RST Temperature Accuracy: +0.5 C Carry Over: < 0.01 % with 500 µl flush volume 396 x 275 x 478 mm 2

EC Detector Technical Specification Principle : Amperometric detector with electrode technique. Working Potential + 2.00 V Storage capacity for Measurement Range 50pC- 200uC(Int. Amp), 5PA-74uA(dc Amp) measurement program 0-99 Auto Zero Range max +50uA Storage capacity for cell-cleaning Manual offset Range max +50uA program 0-99 LCD - Display display of setting and measurement data Analogram Output + 1V per measurement Filter 5Hz - 0.02 Hz (0.2-50 sec) range Counter Electrode Titanium/SST Working Electrode Gold/platinum/Silver electrode with gasket Reference Electrode Ag / AgCl and Polishing kit Detector noise level <0.3 pa Auto-Zero interface active low v Cleaing Potential -+ 2.00 V in 0.001V increment Input 115-320, 50-60Hz Detay time cleaning 10-1500sec Output 12 V DC, 205 A Cleaning Cycle every 1st to 10th cycle Dimensions 260 x 251 x 160 mm Cell Volume <0.5uL Weight 7.6 kg Digital Temperature-Control Detection System Double Conductivity Meter: Structure Detection Mode Conductance cell size Output Voltage Measure range Resolution Conductance temperature Constant Temperature accuracy Baseline Noise Electronic Noise Baseline Drift Five polar ring passively and 316 SS conductance detector. Double Conductivity detection < 0.8 ul 500-5000 mv (to regulate) 0-30000uS/cm (10 level to choose) < 0.025ns 5-50 degree C (to regulate) +0.01 degree C < 0.6 % FS < 10 pa, IPAD: <50 pc < 2.0% FS Analytic Capability High Capacity Anion Column High Capacity Cation Column Analyze repeatability Linear range Minimum concentration of detection ph 0-14 & Reverse phase compatible organic solvent,etc can be analyzed at the same time with one injection Lysine, chlorine chloride can be separated and analyzed 2- < 1.0% (see SO 4 ) >10 3 < 0.0001ug/g (see Cl - ) < 0.005ug/g (see BrO 3- ) < 0.01ug/g(see Ca 2+ ) < 0.001ug/g (see Cu 2+ ) 2- < 0.001ug/g (see CrO 4 ) Anion exchange capacity Operating Pressure (Max.) 100ueq. 15 MPa 3

3411i Column Oven The Analytical 3411i Column Oven is a contact heat transfer oven for high temperature stability and accuracy. The columns are mounted inside the column oven in optimized column holder which enclose the complete column to get the best temperature transfer between the heater and the column. Up to two columns (max. length 250 mm) can be mounted at the same time (max. O.D. 8 mm). Heating The Analytical 3411i Column Oven standard version features a high temperature controller for stable column temperatures of +30 C up to +100 C. The temperature accuracy is within 0.1 C. Heating/Cooling The Analytical 3411i Column Oven is also available with active Heating/Cooling with Peltier technique. The temperature range is +5 C up to +100 C. The Heating/Cooling unit uses the same efficient controller as the basic version with temperature accuracy better than 0.1 C. Leakage Sensor The 3441i Column Oven offers a high sensitive Leakage Sensor which detects the vapors of organic solvents. OEM Options The Analytical 3441i Column Oven itself is available as a complete OEM instrument. Please contact us for any further information on OEM modules. Temperature Time Program The Heating/Cooling variant offers an optional Temperature Time Program for stand-alone operation. Integrated Valve The Analytical 3411i Column Oven offers the option to include an automatic switching valve of the Analytical 3600, for example the 3607 Column Selection Valve, but all 3600 can be integrated. Temperature Fuse Besides a Leakage Sensor the 3441i offers a temperature fuse which shuts down the unit when the temperature becomes too high, because of an electronic defect. Technical Specifications Wetted Materials: Stainless Steel / PEEK 1, PPS 1 Temperature Range: +30 C +100 C (min.: ambient +5 C) optional : +5 C +100 C (Peltier) 2 Temperature Accuracy: < 0.1 C Switching Valve: optional : any Valve Temperature Program: Safety Features: optional with Heating/Cooling (Peltier) Temperature Fuse; Leakage Sensor 396 x 165 x 478 mm 4 1 Switching Valve: depending on configuration 2 Temperature range at 20 C ambient

3412i Column Oven The Analytical 3412i Column Oven is a contact heat transfer oven for high temperature stability and accuracy. The columns are mounted inside the column oven in optimized column holder. Heating The Analytical 3412i Column Oven standard version features a high temperature controller for stable column temperatures of +30 C up to +150 C. The temperature accuracy is within 0.1 C. complete column to get the best temperature transfer between the heater and the column. Up to three 350mm columns can be mounted at the same time. Leakage Sensor The 3412i Column Oven offers a high sensitive Leakage Sensor which detects the vapors of organic solvents. Heating/Cooling The Analytical 3412i Column Oven is also available with active Heating/Cooling with Peltier technique. The temperature range is +5 C up to +100 C. The Heating/Cooling unit uses the same efficient controller as the basic version with temperature accuracy better than 0.1 C. Temperature Time Program The Heating/Cooling variant offers an optional Temperature Time Program for stand-alone operation. Integrated Velve The Analytical 3412i Column Oven offers the option to include an automatic switching valve of the Analytical 3412i, for example the 3600 Column Selection Valve, but all 3600 Valves can be integrated. 5 Temperature Fuse Besides a Leakage Sensor the 3412i offers a temperature fuse which shuts down the unit when the temperature becomes too high, because of an electronic defect. OEM Options The Analytical 3412i Column Oven itself is available as a complete OEM instrument. Please contact us for any further information on OEM modules. Technical Specifications Temperature Range: Stainless Steel / PEEK1, PPS1 +30 C +150 C (min.: ambient +5 C) optional: +5 C +100 C (Peltier) 2 Temperature Accuracy: < 0.1 C Temperature stability: +0.1 C to set temperature Switching Valve: optional: any Valve Temperature Program: Safety Features: optional with Heating/Cooling (Peltier) Temperature Fuse; Leakage Sensor 183 x 566 x 270 mm 1 Switching Valve: depending on configuration 2 Temperature range at 20 C ambient

Regulatory compliances Corporate Social Responsibility Reach us @ Corporate & Regd. Office: Analytical House, # E67 & E68, Ravi Park, Vasna Road, Baroda, Gujarat 390 015. INDIA Analytical Foundation is a nonprofit organizat (NGO) found for the purpose of: 1.Research & Innovation Scientist s awards / QC Professional Award : Quality life is possible by innovation only and the innovation is possible by research only, hence ANALYT- ICAL FOUNDATION is committed to identify such personallities for their contributions across various field of Science and Technoligy and awarding them yearly. To participate for award, send us your details of research / testing / publication at Info@analyticalfoundation.org 2. Improving quality of life by offering YOGA Training courses, Work shops / Seminars etc. 3. ANALYTICAL FOUNDATION aims to DETOXIFY human minds, souls and boby by means of yoga, Meditation, Ayurveda, Health Care, Awards, Media, Events, Comps etc. HPLC Solutions MultipleLabs Analytical Bio-Med Analytical Distributors Analytical Foundation (Trust) T: +91 265 2253620 +91 265 2252839 +91 265 2252370 F: +91 265 2254395 E: info@hplc technologies.com infp@multiplelabs.com info@analyticalgroup.net info@analyticalbiomed.com W. www.ais-india.com www.analycalgroup.net www.hplctechnologies.com www.multiplelabs.com Sales & Support Offices: across the country : Distributors & Channel partners World Wide Note : Company reserves rights to add/delete/modify the contents / technical specificationsof the catalogue without prior notice. 6 Cat.Ver.IC-1609