Cells and cell cultivation

Similar documents
Radially fluent fixed-bed bioreactor

Cell culture system axial

F3 50/500 PILOT AND SMALL INDUSTRIAL PRODUCTION SIP BIOREACTORS/FERMENTORS

F1 1/10 R&D BIOREACTORS/FERMENTORS

Basic design of laboratory bioreactor

F2 15/30 SIP PILOT SCALE BIOREACTORS

CHAPTER 2 CULTURE TYPE

F2 15/30 SIP PILOT SCALE BIOREACTORS

FS 1000/3000 SIP BIOREACTORS/FERMENTORS FOR INDUSTRIAL PROCESSES

Fermenter System Bioreactor Lab / Pilot / Industrial Fermenter Automation Fermenter System

Single-Use Simplicity

MINIFOR Laboratory Fermentor - Bioreactor

BioBundle Systems COMPLETE FERMENTATION SYSTEMS FOR MICROBIAL AND CELL CULTURE APPLICATIONS

Single-Use Simplicity

High Purity Plastics. Properties: PTFE filled lower coefficient of friction good electrical isolating properties FDA conformity

7 Liter BioBundle System Complete fermentation system for microbial and cell culture applications

I/P Pump Tubing. Ensure optimal performance from your Masterflex pump. Consider the following when choosing tubing:

INTRODUCTION. History RAYPA was founded by Mr. Ramón Espinar nd generation take over New makeover

version BROCHURE Laboratory Bioreactor / Fermentor

WHY TO INVEST IN THIS PRODUCT

Labfors 5. THE HIGH-END ALL-ROUNDER. We bring life to your laboratory.

Single-Use Simplicity

L/S Pump Tubing. Ensure optimal performance from your Masterflex pump. Consider the following when choosing tubing:

version BROCHURE Laboratory Bioreactor / Fermentor

I/P Pump Tubing. Ensure optimal performance from your Masterflex pump. Consider the following when choosing tubing:

Bio Reactor Systems. Contact for further information, or call +44 (0)

AUTOCLAVABLE BIOREACTORS


Bioreactor System ERT 314. Sidang /2012

BioBundles. Real bioreactors, really small.

We have what it takes for BIOGAS TESTING

Glass & Quartz Components

Robust flue gas probes for industrial emissions measurements.

OMEGA-GLYDE Polytetrafluoroethylene (PTFE) PC)

MAXX. Mess- und Probenahmetechnik GmbH. Sampling Is Our Passion

EMD Rs... must be deposited along with quotation. Quotation must be submitted into two Bid System 1) Price Bid 2) Technical Bid

KGC SCIENTIFIC FERMENTER DESIGN INDUSTRIAL SCALE

Application of Disposable Technologies in Biopharmaceutical Manufacturing

w Combines biocompatibility of silicone with chemical resistance similar to Tygon

Operation manual. Kalkwasserreaktor

New Brunswick fermentors and bioreactors for research through production

SINTERED WIRE MESH.

Product Overview. Reaction Unit Filter Reactors Pressure Reactors Thin Film Evaporators Short Path Evaporators Rotary Evaporators

If you think vertical sterilizers are all the same, have a look at what we have done: the new FVA /A1 FEDEGARI AUTOCLAVI SPA

Critical Analytical Measurements for Bioreactor Optimization. controlling an organism s chemical environment leads to consistent and

Pure Process Latinoamerica SA de CV Distribuidor Exclusivo.

STANDARD STERILIZABLE IN PLACE SOLUTIONS

bio-t bioreactor systems

Sterilizing Grade Filters USD 2461

Internal Presentation. BIOSTAT Cplus. The SIP Stainless Steel Fermenter Bioreactor for Your Lab

Cellab GmbH - Introduction. June 2014

Price list valid:

RCCS-1 FAQ. The Synthecon Rotary Cell Culture System. 3D Culture Systems for a 3D World RCCS-1. Single Station Rotator Base. Autoclavable Vessel

BIO-WASTE SYSTEMS. Thermal & Chemical Effluent Kill Systems. Biotech & Pharmaceutical. Batch Process Systems. Continuous Process Systems

Chemraz (FFKM) Overview

The TV100-EBK Mini and TV400-EBK Maxi Electroblotters

CIP processes. Product description Bioengineering AG, CH-8636 Wald

Bio Reactor Components from

WESTERN POLYRUB INDIA PVT LTD FLEXIBLE CONNECTORS:

STANDARD PRODUCT RANGE. FRIALIT -DEGUSSIT High Performance Ceramics. www-friatec-ceramics.com

12. Environmental-, soil-, water-, food analysis Sample preparation for standard methods

Sterifix RELIABLE TECHNOLOGY FOR thermal wastewater

EuroFID Total Hydrocarbon Analyzer

High Pressure Filter Assemblies

1. Low profile units 2 Normal profile sterilisation filter units 3. Each pack includes 12 glass-fibre prefilters

Tuchenhagen. Product Recovery Systems

SINGLE, PARALLEL, AUTOCLAVABLE AND SUB DISPOSABLE BIOREACTORS

Pall Supor EKV Sterilizing Grade Filters. USD 2461b

Visual Level Indicators VLI

ZENITH bioreactor Model BIOFERM-01-03

BILFINGER INDUSTRIETECHNIK SALZBURG GMBH BIOREACTORS AND FERMENTERS

STANDARD PRODUCT RANGE. FRIALIT -DEGUSSIT High Performance Ceramics.

ZETA BIRE SYSTEM ZETA INNOVATION PARTNER. Best-in-class bireactor by highly developed scale down from industry process to small scale

High Performance Pump Tubing. Superior Performance in Peristaltic-Pump Applications

NEW. BioFlo / CelliGen 115, Entry-Level Fermentor/ Bioreactor, Liters. System Controllers And Components. Bioprocess Equipment 55

Validation Guide. GBPES-series 0.2, 0.45, & 0.65 Micron Membrane Elements F517A_160901

lumox & x-well Technology

integrity and improved efficiency

Reaction Unit. Bench-top Reactor Pilot-plant Reactor Fully Functional Stand Pilot-plant Reactor Stationary Stand. Asahi Glassplant Inc.

GAURITM P O L Y M E R S. Experts in Hi-Tech Quality Sealing. DMF NO From US FDA

CITSens Bio CITSens MeMo

RUBBERFLATE. The per fect fit for rubber solutions INFLATABLE SEALS - OPBLAASBARE DICHTINGEN - JOINTS GONFLABLE.

STANDARD PRODUCT RANGE. FRIALIT -DEGUSSIT High Performance Ceramics.

lumox & x-well Technology

Compact flue gas analyser: testo 300 M-I

S80 Intelligent Sensors

bio-t mini The Laboratory Bioreactor System

P. pastoris Fermentation using a BioFlo 110 Benchtop Fermentor

testo 335 New measurement engineering for monitoring emissions

Rent a Bioreactor. Bioreactor & Fermentation Technology at acib

Figure 1. Few examples of in-vitro models developed using our products

InTrac Series versatile retractable housings: When process safety is crucial! INGOLD Leading Process Analytics

Handling of TEGO RC Silicones. Hardi Döhler Jürgen Pomorin

SEALING SOLUTIONS FOR THE PROCESS INDUSTRY

Our product range covers a number of different products in silicone rubber, from standard products to advanced special solutions.

Mini-Plant Malt/Beer/Soda Production Plant LT-PPB-01. Production Process. Learn all the necessary to produce malt/beer/soda and then try your product.

Microbiology. Sample collection, cultivation, processing

THINK. Filter Technology SIKA-B

IN SITU STERILIZABLE BIOREACTORS

VENUS AUTOCLAVABLE PRESSURE CONTROLLED R&D FERMENTERS/ BIOREACTORS

Transcription:

Cells and cell cultivation Exclusive and variable for small volumes and applications in biotechnology, medical enginnering, pharmaceutical and food Industries medorex e.k. Industriestr. 2 Tor 1 Phone: +49 (0)5503-8086-62 Fax: -32 Kto-Nr. 11825 BLZ 262 500 01

The exclusive bioreactors medorex fermenters have a high modularity and can be used easy and comfortable in biotechnological, medical and pharmaceutical research and industry. The systems can be offered as stirring reactors, fixedbed bioreactors for the cell cultivation, fluidized-bed bioreactors, mini fermenter or air-lift system. The working volumes of the bioreactors can be varied from 50 ml up to 20 litres. The fermenters work automatically via a central control unit and open up many different cell cultivation ways and tests possibilities for the users. Culture vessels can be offered: As single or double vessel with separable double vessels, with special lid of Peek material for the protection of the sensitive cells from metal molecules and with small diameters for the adaption in multi systems. As "Vario systems" smaller stirring bioreactors with inner and outer vessel working volumes of inner vessels 50-125 or 125-250 ml, to save the expensive nursing-media, and outer vessel volumes of 500 or 1000 ml. Or as standard vessel with 2.0 / 5.0 / 10.0 to 20.0 litres working volumes. Easy possibility of conversion of the reactor-vessels whether in a fluidized-bed system, Air lift, or in a separable double coat vessel for the cell cultivation. All systems are easy convertible. Fittings Sampling fittings, no fore flow, comfortable handling. Option: automatically sampling with mini pumps. Exhaust air condenser with high efficiency, low height. Option: Teflon filter. Air supply fitting with stainless steel frit and Teflon filter. Stirring device with radial magnetic coupling, adjustable, different models of stirrers can be ordered. Lid with ports for sensors and fittings. Small diameters, high lid occupancy density with up to 15 ports and accessibility. Miniature-pO2 sensors 6 mm diameter and 12 mm diameter. Fast tube clutch for sterile connections. Modular measurement and control system Process controller FCU 05, the central control system of up to 4 bioreactors, remote control and easy data exchange of: Speed,, ph, redox, po2, level or AF, gas Mixture and cultivation. Measuring and control module system, equipment depending on need. Materials medorex e.k. Industriestr. 2 Tor 1 Phone: +49 (0)5503-8086-62 Fax: -32 High performance materials: PEEK with high chemical and thermal resistance up to 260 C and FDA admittance, Viton, Teflon, stainless steel, Duran glass; for problematical media it is possible to replace steel by titanium. Kto-Nr. 11825 BLZ 262 500 01

Bioreactors Vessels of PEEK, flanged lids Fast correction by sensors of stainless steel or titanium. Equipped with all necessary fittings and sensors. By sterile magnetic coupling and various stirring systems the instruments can be upgraded/modified for other applications. The production of special designs in consultation with the customers and according to their wishes. Design examples Axial stirred system (1) with stirrer for different stirring tools, homogeneous and culture saving mixing. Fixed bed system (2) to 17 litres working volumes for cell cultivation in batch and operation secure and high productivity. The stirring bioreactors (1, 3, 4, and 5) are used for cell cultivation of shear stress insensitive cells as bacteria and many plant cells. They work completely automatically and are equipped with stirrer, magnet clutch, probes and fittings. They can be converted easy with few basic components into fixed bed systems (2 and 6), fluidized bed or airlift fermenter (7). The fixed bed bioreactors can be used in medical research and pharmaceutical industry for the cultivation of adherent, human and animal cells. The air lift and fluidized bed fermenter can be used in the cultivation of shear stress sensitive cells. The stirring mini-bioreactor "Vario" (4) is offered with double coat vessels for the cultivation of cells with a stable cell wall. The mini bioreactors are offered with 0.5 or 1 litres volume as standard instruments. The capacities of inner vessels are 100-125 ml Vario 500 and 125-250 ml Vario 1000. They can be offered also as multi system with 4 bioreactors. The outstanding features of the mini-bioreactors are separable double vessels with high lid occupancy density, the saving of expensive nursing media with the same cell yield results by the conical forms, the low height and the small diameters of the inner vessels. medorex e.k. Industriestr. 2 Tor 1 Phone: +49 (0)5503-8086-62 Fax: -32 Kto-Nr. 11825 BLZ 262 500 01

Stirring bioreactors Airlift / Fluidized-Bed bioreactors Technical data Work volume 0,5l 1l 2,5l 5l 10l Sterilization Autoclaving Autoclaving Autoclaving Autoclaving Autoclaving Temperature range 5 60 o C 5 60 o C 5 60 o C 5 60 o C 5 60 o C PH range 3-10 3-10 3-10 3-10 3-10 Stirring speed (only 0 2000 0 2000 0 2000 0 1500 0 1000 stirred bioreactors) Tempe ration Within the vessel Within the vessel Within the vessel Within the vessel Within the vessel by heating sticks, by heating sticks, by heating sticks, by heating sticks, by heating sticks, outside the outside the outside the outside the outside the system by double system by double system by double system by double system by double vessel and control system vessel and control system vessel and control system vessel and control system vessel and control system Operation Batch, Fed-Batch, Batch, Fed-Batch Batch, Fed-Batch Batch, Fed-Batch Batch, Fed-Batch PH regulation CO 2 basing CO 2 basing CO 2 basing CO 2 basing CO 2 basing Gas supplement Air, O 2, N 2, CO 2 Air, O 2, N 2, CO 2 Air, O 2, N 2, CO 2 Air, O 2, N 2, CO 2 Air, O 2, N 2, CO 2 Stirring (only stirred bioreactors) Marine propeller or Paddle stirrer Marine propeller or paddle stirrer Marine propeller or paddle stirrer Marine propeller or paddle stirrer Marine propeller or paddle stirrer Ring sparger (air lift/fluidized reactor) Waste gas condenser Sampling system Magnetic clutch (only stirred reactors) Diving pipes Electrodes and cable Light on enquiry on enquiry on enquiry on enquiry on enquiry PC Data acquisition process control system The technical data, the sizes and weights of the bioreactors can be sent when required. medorex e.k. Industriestr. 2 Tor 1 Phone: +49 (0)5503-8086-62 Fax: -32 Kto-Nr. 11825 BLZ 262 500 01

Fixed-bed-bioreactor, axial working principle Fixed-bed-bioreactor radial working principle Technical data Working volumes 0,1l 1l 2,5l 5l 17l Sterilization Autoclaving Autoclaving Autoclaving Autoclaving Autoclaving Temperature range 5 60 o C 5 60 o C 5 60 o C 5 60 o C 5 60 o C PH range 3-10 3-10 3-10 3-10 3-10 Flow rate of pumps 0 10 ml/min 0 100 ml/min 0 250 ml/min 0 500 ml/min 0 2 l/min Tempe ration and control Operation PH regulation Incubator Batch, Fed-Batch CO 2 Within the system by heat sticks & sensors, outside the system by the use of double vessel & control systems. Batch, Fed-Batch CO 2 Within the system by heat sticks & sensors, outside the system by the use of double vessel & control systems. Batch, Fed-Batch CO 2 Within the system by heat sticks & sensors, outside the system by the use of double vessel & control systems. Batch, Fed-Batch CO 2 Within the system by heat sticks & sensors, outside the system by the use of double vessel & control systems. Batch, Fed-Batch CO 2 Gas-addition (outer vessel) Air, O 2, N 2, CO 2 Air, O 2, N 2, CO 2 Air, O 2, N 2, CO 2 Air, O 2, N 2, CO 2 Air, O 2, N 2, CO 2 Gas humidification Waste gas condenser Sampling system Diving pipes Electrodes and cable Light on enquiry on enquiry on enquiry on enquiry on enquiry PC interface on request T Data acquisition on request Process control system on request The sizes and the weights of the bioreactors can be sent on request. medorex e.k. Industriestr. 2 Tor 1 Phone: +49 (0)5503-8086-62 Fax: -32 Kto-Nr. 11825 BLZ 262 500 01

MultiFerm A new multiple cell culture bioreactor for medical and scientific pretesting and tests "MultiFerm" is an automated and easy-to-use 12-fold fixed-bed fermenter system of the parallel cultivation of sensitive animal, human and other shear sensitive cells which are without stable cell wall. The system is used in the production of monoclonal antibodies, cultivation of adherent and recombinant cells and in the cell-physiological studies of tissue cells as example tumour cells, primary cells, stem cells, liver and kidney cells. The fixed-bed system is equipped with the necessary measurement and control facilities, probes and sensors, peristaltic pumps, gas supply, control program and computer for saving, evaluation and transfer of the data to other computers. The system consists of an outer 1.5 l media conditioning vessel and 12 inner fixed bed reactors which are made of Duran glass and are fitted in the middle of the media conditioning vessel. The conditioning vessel is made of Duran glass also. This makes it possible to watch, to check and to control the development of the cell cultivation. The lid, the in and out leads are made of insensitive PEEK material to protect the sensitive cells from damages by free metal ions by the usual metal lids. The fixedbed material consists of highly porous glass sinter pearls or other suitable carrier materials and is inside the fixed-bed reactors. The cells are transferred to the surface of the carrier material in the fixed-bed reactors and grow and increase on, around and between the carrier materials and can be used for further tests and examinations. Depending on cell-types and growth conditions "MultiFerm" is best suited for the parallel cultivation of the same or different cell lines which grow under the same or almost the same growth-conditions. The fermenter system is excellently suited for pre-testing and testing of medicine, biotechnology, pharmaceutical and food industry. medorex e.k. Industriestr. 2 Tor 1 Phone: +49 (0)5503-8086-62 Fax: -32 Kto-Nr. 11825 BLZ 262 500 01

MultiFerm Technical data Total volume Working volume Working principle Sterilization Temperature ranges 1.5 Litre 12 x 10 ml fixed-bed reactors Axial Autoclaving 5 60 o C ph ranges 3-10 Pumps Flow rates Heating Operation for circulation of media and cell cultivation 12 x 0.15 3 ml/min directly via heating stick Batch, Fed-Batch, ph regulation CO 2 Gas-additions (outer vessel) Air, O 2, N 2, CO 2 Gas humidification Waste gas condenser Sampling system Diving pipes Electrodes and cables Light Process control system PC interface Data acquisition Data saving Data transfer to other computers on request Yes The weight and the size of the bioreactor can be sent on request. medorex e.k. Industriestr. 2 Tor 1 Phone: +49 (0)5503-8086-62 Fax: -32 Kto-Nr. 11825 BLZ 262 500 01

Flow chamber bioreactor for medical, biotechnological and pharmaceutical uses Medorex flow chamber bioreactor opens different and excellent possibilities for the cultivation of the functional tissues and adherent cells which need a carrier material for their growth. The fluid-bed bioreactor can be used in the medical technology and research, e.g., in the cultivation of the functioning liver cells, cartilages and flat skin cells. Moreover, it can be used in environment protection and development from drugs in pharmaceutical research. The function of medorex fluid-bed bioreactors Description The fluid-bed bioreactor can be used in the medical technology and research, e.g., in the cultivation of the functioning liver cells, cartilages and flat skin cells. Some cells of the functioning tissue are removed by biopsy and are cultivated in a culture bottle with specific nutrients medium. The cells are transferred after the reproduction to the carrier pads made of polymer, of porous ceramic or fleeceon in the chamber. The cells grow to functioning tissue cultures with corresponding properties. The developed cell cultures are removed enzymatic and further processed. The tissue cultivation process is carried out in an incubator at optimal. The required nutrient medium for the cultivation of cell tissue must be prepared outside the fluid bed chamber. It is enriched with necessary nutrients for growth of the cells. The nutritious medium is pumped by a peristaltic pump and slowly to the cells in the fluid-bed chamber. The spent medium is to remove by means of a pump from the chamber. The aeration of the cells is directly by convection. On this way, the tissues and the cells are optimally supplied with oxygen and nutrients and can grow well. The fluid-bed bioreactor can be used also in cell cultivation for the production of eukaryotic proteins, monoclonal antibodies and other cell substances of research and pharmaceutical industry and with specific bacteria s in the preliminary examinations and tests of the biotechnology e.g. at the reduction of pollutions in the wastewater or in the ground. medorex e.k. Industriestr. 2 Tor 1 Phone: +49 (0)5503-8086-62 Fax: -32 Kto-Nr. 11825 BLZ 262 500 01

medoclav A high-pressure small-batch steriliser with integrated stirring -system "medoclav" is a small media autoclave with an integrated stirring system for the sterilization of max. 7 l media for 1 up to 3 bars pressure and adjustable s up to 143 C. The stirrer of medoclav provides by homogeneous mixing an optimal sterilization of the media under predefined conditions. The of the media autoclave is free adjustable up to a maximum of 143 C. The integrated media sensor and the switch are able to hold the up to 60 C. This makes the bottling of media directly and sterilely by the sample valve easier. Sterilization of solid substances Sterilization of liquids Sterilization in oil bath Sterilization of nutrient media Cultivation of nutrient media (laboratory area) medorex e.k. Industriestr. 2 Tor 1 Phone: +49 (0)5503-8086-62 Fax: -32 Kto-Nr. 11825 BLZ 262 500 01

Tube qualities Please, choose the right tube material for your application Name Silicone PharMed /Santopren Advantages hardly any removing Suitable for Cell from softener and cultures and additions tissue. Impermeable for normal not toxic, resistance, ideal for low light and UV radiation. Tempera-tures, Can be wel- waterproof ded, sticked, formed. resistant to O zon, Low gas per- radiation, sunlight meability. Suitable for the medicine and Food area. Restrictions Not suitable for concentrated solvents, oils, acids or thinned bicarbonate of soda lye. Relatively high gas permeability Remove of additions is possible. TygonLFL The ideal tube for heavy demands. Transparent tube with a high life time, high chemical compatibility. Tasteless. Good dielectric qualities. Low gas permeability. Not suitable for human blood and tissue parts. Viton /Fluran F 5500 Permanency against corrosive media in the high range. Chemically most resistant. Resistance against corrosive media Solvent and oils of high s. Low gas permeability Restricted life time NorprenA60G Ideal for industrial applications. Heat and ozone constant. Good resistance against acids and cousins. Can be welded, sticked and formed. Not aging, not oxidizing. Good dielectric qualities. Long life time and low gas permeability. Removing the additions is possible Physical qualities Polydimethyl-siloxan with silica, silicone oil additions. Compression resistance, transparent,white Polypropylene elastomer, excellent tensile strength nontransparent, beige Flexible and adaptive, transparent Fluorine polymerelastomer non-transparently black Poly propylen elastomer excellent tensile strength non-transparent, black Temperature range Application Acids Bases Solvent Pressure Vacuum viscous Media sterile media Complies with the norms Strerilization Permeability CO2 H2 O2 N2-50 C up to +230 C -50 C to +135 C -50 C up to +74 C -40 C up to +200 C -60 C up to +130 C conditional conditional not suitable Satisfactory satisfactory USP class VlFDA 21 CFR 177.2600 USDA standard With gamma rays or autoclave in a damp atmosphere. Don t sterilize with ethylene oxide.. 1200 16170 x 10-11 200 80 not suitable excellent USP class Vl FDA 21 CFR 177.2600 (only Pharmed) 3 ARPA and NSF Autoclavable without Ageing appearances 1200 772 x 10-11 200 80 not suitable excellent USP class VIFDA Steam and ethylene oxide sterilizing (max. 30 min. at 121 degrees Celsius) 563 362 x 10-11 124 67 Manufacturer's information should be used only as a selection aid. Gas volume (cm3) x IDxW of hose (cm) (Cm2) x Time (sec) x Pressure drop through hose wall (cmhg) Prices on enquiry excellent excellent satisfactory No details Steam and ethylene oxide sterilizing (max. 30 min. at 121 degrees Celsius) 38 24 x 10-11 14 5 not suitable satisfactory excellent not recommendable No details Not recommendable 1200 772 x 10-11 200 80 medorex e.k. Industriestr. 2 Tor 1 Phone: +49 (0)5503-8086-62 Fax: -32 Kto-Nr. 11825 BLZ 262 500 01