LEVEL AND FLOW INSTRUMENTS FOR FLUE GAS DESULFURIZATION

Similar documents
Steam Generation, Waste Heat and Condensate Recovery Level Applications

A Guide to Level Instrumentation for Power Generating Plants

Critical Ethylene Level and Flow Applications and Case Studies

A Guide to Level Instrumentation for Onshore/Offshore Oil Processing

A Guide to Level Instrumentation for the Nuclear Power Industry

A Guide to Level Instrumentation for Onshore/Offshore Oil Processing

Worldwide Pollution Control Association. August 3-4, 2010

Worldwide Pollution Control Association. August 3-4, 2010

1 S P E C I A L A P P L I C AT I O N S E R I E S. magnetrol

LEVEL AND FLOW INSTRUMENTS FOR MODULAR SKID SYSTEMS

Flue Gas Desulphurization (FGD) plant 2 x 600 MW Coal based Thermal power plant Cuddalore, Tamil Nadu. By MK Parameswaran 23 rd Dec, 2016

Wet Flue Gas Desulfurization (FGD)

Fluid Bed Scrubbing TECHNOLOGY

CEMENT PLANT ENVIRONMENTAL TECHNOLOGY FOR ACHIEVING HIGH SO 2 REMOVAL

DRY HYDRATED LIME INJECTION FOR COAL-FIRED BOILER FLUE GAS DESULFURIZATION (FGD) FOREWORD

Energy Production Systems Engineering

Special Applications Series Heat Rate Awareness

Worldwide Pollution Control Association

Worldwide Pollution Control Association

Acid Gas Control Systems. Spray-Dry Scrubbers and Dry Injection Systems. United McGill products. a McGill AirClean product

The Value Proposition of Circulating Fluidized Bed Scrubbing Technology. Robert Giglio Foster Wheeler Global Power Group

WET FLUE GAS DESULFURIZATION (FGD) SYSTEMS ADVANCED MULTI-POLLUTANT CONTROL TECHNOLOGY

1. Introduction. the overall view of the flue gas desulfurization system of Waigaoqiao Thermal Power Station.

Omya Water & Energy omya.com. Flue Gas Cleaning. Sustainable and efficient flue gas desulfurization (FGD)

Air Pollution Control For

TECHNOLOGIES for SO 2 and ACID GAS CONTROL

Evaporative Gas Cooling and Emissions Control Solutions

SOLID-LIQUID SEPARATION TECHNOLOGY FOR REMOVING CONTAMINANT FINES FROM WATER SCRUBBING, CLARIFIER EFFLUENTS AND GREY WATER PAPER NUMBER

INTRODUCTION The absorber is a vertical machine where gases are subjected to chemical treatment. It is called Open Spray Tower ( OST).

What is FGD Gypsum? Presented By E. Cheri Miller Gypsum Parameters, LLC Tennessee Valley Authority (Retired)

Up gradation of Boilers to Implement New Pollution Norms

Gas Suspension Absorber

Abstract. 1 Introduction. Golder Associates Ltd, Canada

Gary Blythe and Ben Bayer, URS Corporation John Grocki, Advantage Resources Consulting, LLC Casey Smith, Lower Colorado River Authority

NEW TECHNOLOGIES IN COAL-FIRED THERMAL POWER PLANTS FOR MORE EFFECTIVE WORK WITH LESS POLLUTION

Thermatel Thermal Dispersion Flow and Level Switches

Your defined goals and objectives:

Verification of Microfine Lime Theoretical Model for SO 2 Removal in Precalciner Cement Plants

Effect of Moisture Conditioning and Handling on Leaching and Physical Properties of Sodium Bicarbonate Flue Gas Desulfurization Materials

Post Combustion CO 2 Capture Scale Up Study

Taravosh Jam Design & Engineering Co.

GE Power. Smarter. Cleaner. Industry. Iron & Steel 2017 STEAM POWER SYSTEMS INDUSTRY PRODUCT CATALOG

Extending The Lifespan & Improving The Efficiency Of Matured FGD Systems: Benefits & Challenges

Treatment Technologies

Flue Gas Desulphurisation (FGD) Vertical Gypsum Centrifuges

Odor Control: working in your neighborhood to protect public health and the environment

Closing the Bottom Ash Loop Pilot Testing Treatment and Reuse for FGD Makeup

Wastewater Treatment and Zero Liquid Discharge Technologies: Overview and New Developments Gordon Maller URS Process Technologies, Austin, TX

Integrated Solutions for the. Food & Beverage. Industry. A Relentless Ally for American Manufacturing

SOME ENERGY-EFFICIENT TECHNOLOGIES IN JAPAN

CENTRAL ELECTRICITY AUTHORITY NEW DELHI

Electric Furnace Off-Gas Cleaning Systems Installation at PT Inco ABSTRACT

Zero Liquid Discharge Effluent Guidelines Compliance Strategies for Coal-Fired Power Plants FGD Wastewater

COAL, OIL SHALE, NATURAL BITUMEN, HEAVY OIL AND PEAT Vol. II -Environmental Impacts of Oil Shale and Pollution Control Technologies - J. Q.

Chapter 2.6: FBC Boilers

Heat and electricity from waste Sysav s waste-to-energy plant

New 790-Megawatt Unit. Council Bluffs Energy Center

AQCS (Air Quality Control System) for Thermal Power Plants Capable of Responding to Wide Range of Coal Properties and Regulations

Dual Flow Tray Technology for Wet FGD Performance Upgrades

POINT SOURCES OF POLLUTION: LOCAL EFFECTS AND IT S CONTROL Vol. II - Clean Coal Technologies - Bingjiang Liu

Mist eliminators for Flue Gas Desulphurization

Markus Gleis. Inserat LAB GmbH

Questions. Downdraft biomass gasifier. Air. Air. Blower. Air. Syngas line Filter VFD. Gas analyzer(s) (vent)

A REVIEW OF EXPERIENCES WITH AL-6XN AND ZERON 100 IN AIR POLLUTION CONTROL EQUIPMENT. *Devin M. Wachowiak and Jason D. Wilson

Waste Water Treatment Equipment

2015 ANNUAL ENGINEERING INSPECTION REPORT PLUM POINT ENERGY STATION CLASS 3N LANDFILL PERMIT NO S3N AFIN:

Carbon Dioxide Pretreatment of AMD for Limestone Diversion Wells

CCR COMPLIANCE FUGITIVE DUST CONTROL PLAN. Prepared for: GenOn Northeast Management Company Conemaugh Generating Station New Florence, Pennsylvania

Application of Circulating Fluidized Bed Scrubbing Technology for Multi Pollutant Removal

CHAPTER 1 INTRODUCTION

Integrated Solutions for the. Power Generation. Industry. A Relentless Ally for American Manufacturing

Screw Decanter Concentration System

A Review of Sulfide Smelting Process Gas Handling Systems

Magnesium Hydroxide Conversion Project From Quicklime Alone to Mixed Mode Treatment with FloMag H Magnesium Hydroxide Slurry and Quicklime

Ash and Material Handling Capabilities

Your partner for the right solution

ENVI-Marine Emission Control Systems

Methanol Production by Gasification of Heavy Residues

Control of sulfidity in a modern kraft pulp mill

IRISH CEMENT PLATIN INVESTING IN OUR FUTURE

Biomass Boiler Emission Abatement Technologies. Simon Wakefield

ENVIRONMENTAL ENGINEERING 343

a long-term sustainable solution for waste

U. S. Army Corps of Engineers Metals Precipitation Checklist

Phosphate Plant Yield Comparisons

FLUE GAS DESULFURIZATION FOR 2 X 6 MW COAL FIRED POWER PLANT

Wet-To-Dry-Conversion. Bottom Ash Systems

BENEFICIAL USE OF COAL COMBUSTION PRODUCTS AN AMERICAN RECYCLING SUCCESS STORY

Ms. Valérie Léveillé Cansolv Technologies, Inc. Thys Claassens Chemical Initiatives

Wheelabrator Air Pollution Control Inc.

Semi-Bulk Systems, Inc.

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

THE EXCELLENCE IN FILTRATION, BY NATURE WATER TREATMENT & SILT MANAGEMENT WASHING PRODUCT RANGE

Worldwide Pollution Control Association

Air Pollution Technology Fact Sheet

SCRUBBER SUMP SYSTEM PROCESS DESCRIPTION Document No

Economics of Lime and Limestone for Control of Sulfur Dioxide

Welcome to. ASHTECH TECHNOLOGIES PVT. LTD. (Pneumatic Conveying Systems) ASHTECH House, 30 POPATWADI, KALABDEVI ROAD MUMBAI (India)

Zero liquid discharge. Reduce end-of-pipe streams Increase values

VGC Gypsum Centrifuge Flue Gas Desulphurisation (FGD)

Transcription:

LEVEL AND FLOW INSTRUMENTS FOR FLUE GAS DESULFURIZATION S p e c i a l A p p l i c a t i o n S e r i e s

2 FGD: An Industry Perspective The reduction of air pollution has been mandated by several Clean Air Acts beginning in 1963 and followed by major revisions and amendments throughout the successive decades. The Amendments of 1990 specifically addressed acid rain caused by sulfur dioxide (SO 2 ) emissions from fossil-fueled electric power plants and, to a lesser extent, from other industrial sources. The more stringent Phase II of this Act went into effect in 2000. With the new emissions standards arriving at a time when energy prices and global warming dominate the news, Flue Gas Desulphurization (FGD) technology has become the hot topic of power generation. The number of FGD units operating between 1971 and 2001 grew from 0 in two countries to over 700 in 30 countries. Power plants in the U.S. are expected to spend $200 billion for FGD systems between 2005 and 2020. Of the 2.2 million megawatts of coal-fired plants in operation by 2020, two-thirds will be equipped with FGD systems. Though many variations in the FGD process exist, approximately 85% of the units installed in the U.S. today are the wet scrubber variety. With up to 99% SO 2 removal efficiency, wet scrubber technology is the only practical method for treating boiler gas generated from the combustion of medium to high sulphur coal. With all the coal-fired power plants now in existence and the number of new plants in planning stages around the world, the market for FGD systems is growing rapidly. The Wet FGD Process Flue Gas Desulphurization is widely acknowledged as today s state-of-the art technology for removing sulfur dioxide from the exhaust flue gas in coal- and oil-fired power plants. In the "wet limestone-gypsum" form of FGD, an aqueous slurry of finely ground limestone is introduced into an absorber tower and contacted with the flue gas. The interaction results in the conversion of SO 2 in the gas stream into calcium sulfate, or gypsum, with carbon dioxide (CO 2 ) being routed up the stack. As diagrammed at right, a typical FGD system consists of four units operating simultaneously: (1) Limestone Processing; (2) Gypsum Recovery; (3) Wastewater Treatment; and () SO 2 Scrubbing (or Absorption). The level and flow control applications found in these units are discussed in the pages ahead.

3 1. Limestone Processing Limestone is the most extensively used reagent in today's utility industry. Limestone arrives by truck and train and is transferred from the limestone bunker to the ball mill where it is ground into a fine powder. The ground limestone is then transferred to the hydrocyclone feed tank where makeup water is added. The slurry proceeds to the limestone slurry storage tanks from where it enters the SO 2 absorber tower. There the flue gas is contacted by the limestone slurry resulting in the conversion of SO 2 in the flue gas to calcium sulfate, or gypsum. The gypsum is typically recovered for resale. TRUCK AND RAIL UNLOADING OF LIMESTONE LIMESTONE HOPPERS 2 LIMESTONE BUNKER GRINDING MILL LIMESTONE STORE 3 1 PROCESS WATER FLUE GAS IN HYDROCYCLONES EMISSION GAS OUT SO 2 ABSORBER TO ABSORBER HYDROCYCLONE FEED 5 LIMESTONE SLURRY FEED Level and Flow Applications for Limestone Processing ❶ Limestone Store Limestone is delivered either as crushed stone or pre-ground powder. Unground limestone from road or rail hoppers is conveyed to the limestone store for storage. A limestone reclaim machine operates within this vessel. Point Level: Solitel Vibrating Rod Level Switch for bulk solids. ❷ Limestone Bunker Unground limestone is transferred from the limestone store to a bunker prior to its conveyance to the ball mill for grinding. The bunker is a day silo containing a 16- to 2-hour supply. Point Level: SOLITEL Vibrating Rod Level Switch for bulk solids ❸ Pump Protection Process water is added to limestone between the bunker and the grinding mill and again in the hydrocyclone feed tank. A flow switch positioned along the pump s discharge piping will actuate an alarm and shut down the pump when liquid flow drops below the minimum flow rate. Flow Alarm: Thermatel TD1/TD2 Switch for low flow cutoff ❹ Hydrocyclone Feed Tank Hydrocyclones separate solid-liquid suspensions through centrifugal sedimentation. An agitated hydrocyclone feed tank supplies the separator. Continuous Level: Pulsar Thru-Air Radar; Eclipse or Horizon Guided Wave Radar (GWR); or Echotel Ultrasonic Transmitters Point Level: THERMATEL TD1/TD2 Switch with Spherical Tip for Hi/Low Alarm ❺ Limestone Slurry Feed Tank Hydrated lime stored in steel or poly tanks is kept in suspension with a slow speed mechanical agitator. The slurry fed to the absorber serves as the scrubbing reagent. Continuous Level: PULSAR Thru-Air Radar; ECLIPSE/HORIZON GWR; or ECHOTEL Ultrasonic Transmitters Point Level: THERMATEL TD1/TD2 Switch for Hi/Low Alarm

2. Gypsum Recovery Although the FGD process was originally established for environmental purposes, a large amount of high quality, synthetic gypsum is created as a byproduct of the scrubbing process. Gypsum is widely used as a source material for manufacturing wallboard and as a conditioner for agricultural soils. Because of its commercial value, most FGD systems incorporate equipment to recover, dewater and store gypsum for resale. The gypsum slurry pumped from the absorber is fed to the centrifuge feed tank. The centrifuge reduces the gypsum slurry to a dewatered cake containing less than 10 percent moisture by weight. TO LIMESTONE SLURRY FEED SO 2 ABSORBER GYPSUM SLURRY 2 CENTRATE 1 CENTRIFUGE FEED GYPSUM LOADING DEWATERING UNIT 3 CENTRIFUGE PUMP GYPSUM STORAGE Level and Flow Applications for Gypsum Recovery ❶ Centrifuge Feed Tank The gypsum slurry is pumped from the absorber to the centrifuge feed tank. Centrifuge operation is initiated by a level controller located in the centrifuge feed tank. Continuous Level: ECLIPSE or HORIZON GWR; or PULSAR Thru-Air Radar Transmitters ❷ Centrate Tank The gypsum slurry stream (centrate) produced in the gypsum dewatering operation is routed for residence in a centrate tank prior to its introduction into the limestone slurry feed tank to serve as an additive. Continuous Level: ECLIPSE or HORIZON GWR; PULSAR Thru-Air Radar; ECHOTEL Ultrasound; Kotron RF Capacitance; or E3 Modulevel Displacer Transmitters Point Level: ECHOTEL Ultrasonic Switch; KOTRON RF Capacitance Switch; or Float and Displacer Switches ❸ Centrifuge Pump Protection Process water is added to the gypsum dewatering centrifuge. A flow switch along the pump s discharge piping will actuate an alarm and shut down the pump when liquid flow drops below the minimum flow rate. Point Level: THERMATEL TD1/TD2 or F10 Mechanical Flow Switch ❹ Gypsum Storage Dewatered gypsum is transferred to a gypsum storage vessel equipped with a gypsum reclaim machine. The gypsum may later be transferred to a storage shed. Point Level: SOLITEL Vibrating Rod Level Switch for bulk solids A front-end loader fills a dump truck with gypsum.

5 3. Wastewater Treatment A dedicated wastewater facility properly integrated with the FGD scrubber operation is typically required to meet the very strict SO 2 ABSORBER PRIMARY AND SECONDARY HYDROCYCLONES 2 wastewater discharge requirements CHEMICAL S that ensure water returned to the source will meet quality standards set by the regulatory authority. A well-designed treatment facility 1 WATER EQUALIZATION includes a number of technologies such as lime neutralization, gypsum desaturation, clarification, filtration, biological treatment, and sludge thickening and dewatering. 5 SLUDGE PUMP PROTECTION 3 CLARIFIER GRAVITY FILTER 6 TREATED WATER OUTPUT SLUDGE DEWATERING CAKE Level and Flow Applications for Wastewater Treatment ❶ Water Equalization Tanks Wastewater is held in the equalization tank to allow solids to begin settling and to help maintain a more constant flow rate through the treatment unit. Continuous Level: ECLIPSE or HORIZON GWR; PULSAR Thru-Air Radar; ECHOTEL Ultrasound; KOTRON RF Capacitance; or E3 MODULEVEL Displacer Transmitters Point Level: ECHOTEL Ultrasonic Switch; KOTRON RF Capacitance Switch; or Float and Displacer Switches ❷ Chemical Storage Tanks An array of chemicals are added from feed tanks to facilitate processing, adjust water quality and chemistry, and inhibit corrosion, scaling, or other conditions. Continuous Level: ECLIPSE or HORIZON GWR; PULSAR Thru-Air Radar; ECHOTEL Ultrasound; KOTRON RF Capacitance; Enhanced Jupiter Magnetostrictive; or E3 MODULEVEL Displacer Transmitters Point Level: ECHOTEL Ultrasonic Switch; KOTRON RF Capacitance Switch; or Float and Displacer Switches ❸ Clarifier Level Wastewater influent slowly passes through clarifiers where sludge settles and floating material can rise to the surface to be skimmed off. The sludge is pumped away for further treatment. Continuous Level: ECHOTEL Ultrasonic; KOTRON RF Capacitance; or ECHOTEL Non-Contact Transmitters ❹ Sludge Output Pump Protection A flow switch along the pump s discharge piping will actuate an alarm and shut down the sludge pump when liquid flow drops below the minimum flow rate. Flow Alarm: THERMATEL TD1/TD2 Switches ❺ Sludge Tank Level Sludge that settles at the bottom of the clarifier is pumped to a sludge tank where level is monitored to control against incomplete discharge or dilution of the sludge. Continuous Level: ECLIPSE or HORIZON GWR; or ECHOTEL Ultrasonic Transmitters ❻ Treated Water Output Flow measurement is accomplished by a transmitter programmed to convert a level reading into units of volume per time as liquid passes through a flume or weir in an open channel. Continuous Level: ECHOTEL Non-Contact Ultrasonic Transmitters

FLUE GAS STREAM 6. SO 2 Absorption BOILER STACK 5 DEMISTER WATER FEED 6 FLUE GAS PRECIPITATOR HYDROCYCLONES REACTION 1 2 SUMPS ACID STORAGE LIMESTONE SLURRY IN 3 AIR COMPRESSOR UNDERFLOW TO GYPSUM RECOVERY FEED 7 PURGE TO WATER TREATMENT SO2 Absorption System The SO2-laden boiler flue gas stream passes through the electrostatic precipitators and into the absorber column. Inlet wash water used to prevent a buildup of solids in the inlet duct cools the flue gas as it enters the absorber. The SO2 absorption process begins as the flue gas is scrubbed by the recirculating limestone slurry that also washes out the remaining pulverized fuel ash. (When particulate content of the gas is very high a venturi scrubber may be necessary to remove residual particles). The reagent suspension used in the scrubbing process is water containing approximately 20% fine-grained limestone. The slurry is pumped from the bottom of the absorber and is sprayed downward from nozzles arranged at separate levels in the absorber tower. Process chemistry transforms the recirculating slurry into gypsum and a portion of it is continuously pumped away to the primary and secondary hydrocyclones for separation and dehydration. Water removed from the scrubber purge stream is then pumped to the water treatment unit.

7 Level and Flow Applications for the SO 2 Absorption System ❶ Sump Overflow and Leak Detection Small sumps are positioned under tanks plantwide to contain leaks or spills. Sumps also contain leaks from pumps, valves, and pipelines. Point level: Top Mounting Displacer Switch; ECHOTEL Ultrasonic Switch; Float-actuated Flood Level Switch; THERMATEL TD1/TD2 Switch with a Spherical Tip; or KOTRON RF Capacitance Switch ❷ Dibasic Acid (DBA) Storage Tank Organic acid additives improve scrubbing efficiency and reliability, and reduce tower operating cost. DBA is typically stored in a heated, agitated tank from where the acid is fed into a limestone slurry tank or directly into the scrubber. Continuous Level: PULSAR Thru-Air Radar with a -inch horn; or ECLIPSE Guided Wave Radar ❸ Oxidation Air Compressor The FGD absorber is equipped with an oxidation air system to provide oxidation air for the absorber vessel. Continuous Flow: THERMATEL TA2 Mass Flow Transmitter Flow Alarm: THERMATEL TD1/TD2 Switch; or F10 Mechanical Flow Switch for low flow cutoff ❹ Absorber Reaction Tank The recycle slurry falls from the spray zone into the reaction tank located at the base of the absorber. This tank is sized to provide sufficient residence time for all of the gypsum precipitation and limestone dissolution reactions to take place. Continuous Level: PULSAR Thru-Air Radar equipped with a - or 6-inch horn and mounted within a 30- to 0-foot stilling well; ECLIPSE GWR with a flexible probe; or KOTRON RF Capacitance with a flexible probe (least recommended, but commonly used on this application). ❺ Demister Water Feed Process water flow to the demister affects the continuous and reliable running of the FGD system. Interrupted water feed can not only stop the FGD system but also shut down the power generating unit. Flow Alarm: THERMATEL TD1/TD2 Switch or F10 Mechanical Flow Switch for low flow cutoff ❻ Flue Gas Treated gas passes from the absorber through outlet dampers and into the chimney where the off-gases are discharged directly to the atmosphere. A mass flow meter may be used to measure the treated gas flow. Continuous Flow: THERMATEL TA2 Mass Flow Transmitter ❼ Absorber Purge Tank and Wastewater Outlet After the slurries pass through the hydrocyclones, wastewater is purged in the absorber purge tank to avoid accumulation of impurities in the system. The wastewater is then routed to water treatment for processing. Continuous Level: ECLIPSE or HORIZON GWR; PULSAR Thru-Air Radar; ECHOTEL Ultrasound; KOTRON RF Capacitance; Enhanced JUPITER Magnetostrictive; or E3 MODULEVEL Transmitters. Point Level: Float and Displacer Level Switches Flow Alarm: THERMATEL TD1/TD2 Switch; or F10 Mechanical Flow Switch

S p e c i a l A p p l i c a t i o n S e r i e s Instrumentation from Magnetrol Guided Wave Radar Eclipse and Horizon transmitters are twowire, loop-powered, 2 VDC level transmitters based on Guided Wave Radar (GWR) technology. Available in coaxial, twin rod and single rod probes, these leading-edge transmitters provide measurement performance well beyond that of many traditional technologies. Available with HART, FOUNDATION fieldbus and PROFIBUS outputs Float & Displacer Float-actuated switches are available in top-mount and side-mount styles for high or low level alarm, interface, and pump control applications.top-mounting displacer type level switches offer the industrial user a wide choice of alarm and control configurations. Displacer based electronic and pneumatic transmitters offer -20 ma or HART output. Thru-Air Radar PULSAR Pulse Burst Radar level transmitters are the latest generation of loop-powered, 2 VDC, liquid level transmitters. They offer lower power consumption, faster response time and are easier to use than most looppowered radar transmitters. PULSAR is available in a dielectric rod or horn antenna style. Ultrasound ECHOTEL contact and non-contact ultrasonic level transmitters and switches are available in a range of models to provide users with the features and options suitable for their specific application. The Models 961 single point and 962 dual point switches are available with relay or current shift electronics. Thermal Dispersion THERMATEL Models TA1 and TA2 Mass Flow Transmitters provide reliable mass measurement for air and gas flow applications. THERMATEL switches provide a high level of performance in flow, level and interface applications for air, gas and liquids. A hygienic version of the TD2 switch is available for sterile, Clean-In-Place applications. Visual Indication Atlas, Aurora and Gemini are magnetically coupled liquid level indicators precision engineered and manufactured to provide accurate, reliable, and continuous visual level indication. AURORA provides redundant control with both a float and an ECLIPSE Guided Wave Radar transmitter. RF Capacitance KOTRON RF Capacitance level switches and transmitters are available in nine different models to provide a wide range of features to suit a large array of applications and process media. Vibrating Rod SOLITEL Vibrating Rod Level Switches provide reliable level detection of powders and bulk solids. This compact, integral switch is suitable for high or low level detection in hoppers or silos. Magnetostriction The Enhanced JUPITER magnetostrictive transmitter provides a -20 ma output proportional to the level being measured or Foundation fieldbus output. May be externally mounted to a MLI or inserted directly into the process vessel. PLEASE NOTE: The instruments recommended in this guide are based on field experience with similar applications and are included as a general guide to flow control selection. However, because all applications differ, customers should determine suitability for their own purposes. Worldwide Level and Flow Solutions SM CORPORATE HEADQUARTERS: 5300 Belmont Road Downers Grove, Illinois 60515-99 USA Phone: 630-969-000 Fax: 630-969-989 BELGIUM: Heikensstraat 6 920 Zele, Belgium Phone: 052 5.11.11 Fax: 052 5.09.93 e-mail: info@magnetrol.com website: magnetrol.com Magnetrol & Magnetrol logotype, Orion Instruments & Orion Instruments logotype, Echotel, Eclipse, Horizon, Kotron, Modulevel, Pulsar, Solitel, Thermatel, Atlas, Aurora and Jupiter are trademarks of Magnetrol International, Incorporated. FOUNDATION fieldbus is a trademark of the Fieldbus Foundation. HART is a registered trademark of the HART Communication Foundation. PROFIBUS is a registered trademark of PROFIBUS International. PACTware is a trademark of the PACTware Consortium. Copyright 2012 Magnetrol International, Incorporated. All rights reserved. Printed in the USA. Bulletin: 1-179.0 Effective: October 2008