Building Systems. 1-Part Silicone Weatherseal for Structural Glazing. Product Description. Product Data Sheet Edition_1, 2009 Sikasil WS-305 CN

Similar documents
Product Data Sheet Edition 25/01/2006. Sikasil WS-305. Product Description. Uses. Characteristics / Advantages

Product Data Sheet Edition 25/01/2006. Sikasil SG-500. Product Description. Uses. Characteristics / Advantages

Product Data Sheet Edition 25/01/2006. Sikasil IG-25. Product Description. Uses. Characteristics / Advantages

1-part polyurethane sealant for building joints

Non-sag, ultra low modulus, neutral cure silicone sealant for pavements

1-part elastic joint sealant and multipurpose adhesive

1-part elastic joint sealant and multipurpose adhesive

PRODUCT DATA SHEET Sikadur 31 CF Normal (formerly Sikadur 731)

Sikaflex PRO-3 PROVISIONAL PRODUCT DATA SHEET HIGH-PERFORMANCE SEALANT FOR FLOOR JOINTS AND CIVIL ENGINEERING APPLICATIONS DESCRIPTION

Sikaflex -1a. One-Part Polyurethane, elastomeric sealant/adhesive. Product Description. Product Data

Construction. 1-part floor joint sealant. Product Description. Product Data. Tests. Form. Storage

1-part Flexible Sealant for Concrete and Masonry Facades

1-part elastic joint sealant and multipurpose adhesive

TECHNICAL DATA SHEET SIKABOND AT METAL GREY 300CC

1-part polyurethane pourable self levelling floor joint sealant

Construction. 1-part elastic joint sealant and multipurpose adhesive. Product Description

1-part high performance sealant for flooring

PRODUCT DATA SHEET Sikaflex PRO-3 WF

CHARACTERISTICS / ADVANTAGES

TECHNICAL DATA SHEET SIKAFLEX FLOOR

1-part elastic joint sealant and multipurpose adhesive

CHARACTERISTICS / ADVANTAGES

Construction. 1-part high performance sealant for flooring. Product Description. Environmental Information. Product Data Sheet Edition _1

TECHNICAL DATA SHEET SIKAFLEX 11FC + WHITE CT

PRODUCT DATA SHEET Sikaflex Tank N

One-part High Performance Sealant for Flooring

OLIVÉ C-22 LOW MODULUS NEUTRAL SILICONE PRODUCT DESCRIPTION:

TECHNICAL DATA SHEET SIKAFLEX PRO-3 SELF LEVELLING

1-part Elastic Sealants for Joints Exposed to Chemicals

1-part elastic sealant for joints exposed to chemicals

PRODUCT DATA SHEET Sikaflex Tank N

Conforms to the requirements of ETAG Certificate: European Technical Approval No. ETA-05/0265

TECHNICAL DATA SHEET SIKADUR 31 CF NORMAL 6KG

DOWSIL 796 Neutral Silicone

Construction. 1-part elastic sealant for the internal and external caulking of wooden floors. Product Description. Product Data. Form.

PRODUCT DATA SHEET. Sikafloor -CureHard-24 PRODUCT DESCRIPTION. Transparent surface hardener, dustproofer, sealing and curing compound for concrete

V-70. High Strength Structural Glazing Silicone Adhesive Sealant

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric sealant

3-part thixotropic epoxy patching mortar

PRODUCT DATA SHEET SikaBond T55 (J)

1-part high performance polyurethane sealant for building joints. ISO 11600(Type F Class 25HM/20LM)

CHARACTERISTICS / ADVANTAGES

Product Data Sheet Sikadur -31 CF Normal Product Description Uses ruction Const Characteristics / Advantages

General Guidelines Solutions for Facades Application of Sikasil Weather Sealants. January 2010 / Version 1

Low viscous (easy flowing) elastic adhesive for wood flooring

Construction. Low viscous (easy flowing) elastic adhesive for wood flooring. Product Description. Product Data

Contractors SCS1001. Contractors SCS1000 sealant is available in 4 colors plus. General Glazing: Glass, plastic, channel or stop.

Industry. Sika Facade Systems Sikasil Product Overview Engineering Silicones for Facades

TECHNICAL DATA SHEET SIKADUR 31 RAPID 1.2KG

Construction. Solvent free elastic adhesive for wood flooring. Product Description

Construction. Low viscous (easy flowing) elastic adhesive for wood flooring. Product Description. Product Data

Construction. SikaMembran system Vapour control/waterproofing sheet system for ventilated curtain walling

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric Sealant

High viscous (thixotropic) elastic adhesive for wood flooring

Construction. Solvent free elastic adhesive for wood flooring. Product Description 1 1/6

Construction. Universal anchoring adhesive. Product Description. Tests. Product Data Sheet Edition _1. 1 Sika AnchorFix S 1/6

- TECHNICAL DATA SHEET

PRODUCT DATA SHEET Sikadur -31 DW

PRODUCT DATA SHEET Sika AnchorFix -S

Dow Corning 791 Silicone Weatherproofing Sealant

CHARACTERISTICS / ADVANTAGES. Yellowish-transparent. PACKAGING 20 kg per pail

DIVISION 7 - THERMAL AND MOISTURE PROTECTION Section Joint Sealers Elastomeric and non-elastomeric Sealant

Product Data Sheet Product n Description Uses tio tru Characteristics / C Advantages Tests Approval / Standards

PRODUCT DATA SHEET Sika AnchorFix -2+ Tropical

General Guidelines Solutions for Facades Application of Sikasil Weather Sealants. February 2013 / Version 2

Footfall sound dampening system for wood flooring

PRODUCT DATA SHEET Sikadur -32 Normal

PRODUCT DATA SHEET. Sika Unitherm Steel S exterior. (formerly Sika Unitherm exterior) PRODUCT DESCRIPTION

V60 Architectural Grade Silicone

T E C H N I C A L D A T A S H E E T

Sikafloor -375 is a two part, solvent free, low viscosity, tough elastic, crackbridging polyurethane resin coating. CHARACTERISTICS / ADVANTAGES

3-component epoxy self-smoothing screed

Easy spreadable, solvent free elastic adhesive for wood flooring

Construction. Easy to spread, semi-elastic adhesive for full surface wood floor bonding. Product Description. Product Data. Form.

Footfall sound dampening system for wood flooring

Sikadur -31 DW Rapid (VP)

Sikalastic -821 LV is a two part, elastic, crack-bridging, rapid-curing polyurethane membrane. Sikalastic -821 LV is for machine application only.

SECTION JOINT SEALANTS PART 1 - GENERAL 1.01 RELATED DOCUMENTS

SEALING & BONDING JOINT SEALANTS FOR CURTAIN WALL AND STORE FRONT WATERPROOFING

POLYSEAL PS POLYSULPHIDE JOINT SEALANT

POLYSEAL PS POLYSULPHIDE JOINT SEALANT

PRODUCT DATA SHEET Sikagard -720 EpoCem

TECHNICAL DATA SHEET SIKA ANCHORFIX-1 GREY 300ML (6's)

Segmental bridge adhesive

SIKAFLEX MS (BUILDING SEALANT) Product. Scope. Appraisal No. 311 [2013]

HYPERSEAL -EXPERT-150

A. This specification describes the sealing of vertical joints/cracks with a one-component, gungrade, elastomeric sealants. B.

Construction. Easy Clean, solvent & isocyanate free, elastic adhesive for full surface bonding of wood flooring. Product Description.

Construction. Easy Clean, solvent & isocyanate free, elastic adhesive for full surface bonding of wood flooring. Product Description.

UltraPruf II SCS2902

Construction. Universal anchoring adhesive. Product Description 1 1/7. Product Data Sheet Edition _1 Sika AnchorFix -S

AUTHORIZED SIKA DISTRIBUTOR PRODUCT SELECTOR GUIDE FOR MINERAL GLASS

DOWSIL Neutral Plus Silicone Sealant

Technical Data Sheet Version 04/2019 MS PowerFlex 25

J-SEAL PU 1 POLYURETHANE JOINT SEALANT

Roofing. Sarnacol Adhesive for Insulation Boards. Product Description. Product Data. Polyurethane-based humidity-hardening one-pack adhesive

Spray applied polyurea membrane

TECHNICAL DATA SHEET SIKABOND-52 WOOD FLOOR 600ML (20/BOX)

Water resistant bonding agent and mortar additive

Sikadur -Combiflex CF Adhesive Type N and Type R are thixotropic two part adhesives based on epoxy resins and fillers.

Transcription:

Product Data Sheet Edition_1, 2009 CN Building Systems 1-Part Silicone Weatherseal for Structural Glazing is a neutral, 1-part, moisture curing, elastic joint sealant Product Description based on silicone. Uses is a high-performance silicone sealant designed for sealing, bonding and mending tasks in glazing applications. It is particularly suitable for use as weatherseal for structural glazing and curtain walling. is suitable for use on alkaline substrates such as concrete and mortar. Characteristics / Neutral curing system Advantages Ready to use Solventless Non-sag Ready gunnability at low (+5 C) and high (+40 C) temperatures Rapid curing Low shrinkage on curing After cure: elastic at low (-40 C) and high (+150 C) temperatures Bonds to many materials without primer Outstanding UV and weathering resistance Compatible with water-based and solvent-based paints: no migration of plasticizer Not corrosive to metals External quality control Wide range of colours Long shelf-life: simplified stock-keeping 1 1/6

Tests Approvals / Standards ISO 11600: Classification of sealants for Building Construction: F+G-25 LM DIN 18540: Sealing of joints in external walls using building sealants DIN 18545: Sealing of glazing with sealants, Part 2 Sealants, designation, requirements, testing. Result: Type E sealant. BS 5889; 1989: One-part gun grade silicone-based sealants : type A Sealant for general use in construction joints ASTM C920: Elastic joint sealants: Type S, Grade NS, Class 50, Use NT, G, A and M TT-S-001543 A: Sealing compound: silicone rubber base (for caulking, sealing and glazing in buildings and other structures). Class A compounds resistant to 50% maximum total joint movement. TT-S-00230 C: Sealing compound: elastomeric type, single component (for caulking, sealing and glazing in buildings and other structures), type II, class A. AENOR: Marca N: Reg. No. 047/00245 Classification F+G-25 LM UNI 9610, 9611: Silicone sealant for joints-requirements and tests, packaging. Product Data Form Colour See product overview. On request, Sika can supply any colour, matched to the customer s sample. For further information, contact your sales manager or your nearest Sika sales office. Packaging 600 ml sausages, 20 sausages per box 310 ml cartridges, 25 cartridges per box 300 ml cartridges, 25 cartridges per box Other packaging, e.g., for industrial applications, can be supplied on request. Storage Storage Conditions / Shelf Life 15 months from date of production if stored in undamaged original sealed containers, in dry conditions and protected from direct sunlight at temperatures between +5 C and +25 C. Technical Data Chemical Base 1-part silicone, moisture curing Density ~ 1.03 kg/l (transparent, aluminium) (ISO 1183-B) ~ 1.49 kg/l (all other colours) Skinning Time ~ 20 minutes (+23 C / 50% r.h.) Tack-free Time ~ 180 minutes Curing Rate ~ 4 mm / 24 h (+23 C / 50% r.h.) Movement Capability ± 25% (ISO 11600) ± 50% (ASTM C920) Joint Dimensions 6 mm min. width / 40 mm max. width Sag Flow Non-sag (ISO 7390, Profile U20) Service Temperature -40 C to +150 C (after vulcanization) 2 2/6

Mechanical Properties Tear Strength ~ 4.0 N/mm after 4 weeks (+23 C / 50% r.h.) (ISO 34-C) Shore A Hardness ~ 20 after 4 weeks (+23 C / 50% r.h.) (ISO 868) E-Modulus ~ 0.33 N/mm 2 at 100% elongation after 4 weeks (+23 C / 50% r.h.) (ISO 37, rod S2) ~ 0.30 N/mm 2 at 100% elongation after 4 weeks (+23 C / 50% r.h.) (ISO 8339-A) Tensile Strength ~ 0.90 N/mm 2 after 4 weeks (+23 C / 50% r.h.) (ISO 37, rod S2) ~ 0.50 N/mm 2 after 4 weeks (+23 C / 50% r.h.) (ISO 8339-A) Elongation at Break ~ 820% after 4 weeks (+23 C / 50% r.h.) (ISO 37, rod S2) ~ 380% after 4 weeks (+23 C / 505 r.h.) (ISO 8339-A) System Information Application Details Consumption The joint width must be designed to accommodate the movement capability of the sealant. The joint width must be > 6 mm and < 40 mm. The width to depth ratio of ~ 2:1 must be respected. Standard dimensions for concrete elements (as per DIN 18540 / table 3) Joint distance 2 m 2 3.5 m 3.5 5 m 5 6.5 m 6.5 8 m Joint width 15 mm 20 mm 25 mm 30 mm 35 mm Joint depth 8 mm 10 mm 12 mm 15 mm 15 mm Minimum joint width for perimeter joints around windows: 10 mm Joints must be properly dimensioned as changes are no longer possible after construction. Basis for calculation of the necessary joint width are the technical characteristic values of the joint sealant and the adjacent building materials, the exposure of the building elements, their construction and size. Joint width 8 mm 10 mm 15 mm 20 mm 25 mm 30 mm Joint depth 6 mm 8 mm 8 mm 10 mm 12 mm 15 mm Joint length / ~ 12.5 m ~ 7.5 m ~4.5 m ~ 2.5 m ~ 1.6 m ~ 1.3 m 600 ml The stated values are indication only. Backfilling: It is recommended to use closed cell, sealant compatible foam backer rods e.g. high resilience polyethylene foam rod. If joints e.g. triangle joints are too shallow for backing material to be employed, we recommend using a polyethylene tape. This acts as a release film (bond breaker), allowing the joint to move and the silicone to stretch freely. 3 3/6

Substrate Preparation / Cleaning Priming Substrates must be clean and dry, homogeneous, free from grease, dust and loose particles. Contaminated surfaces may be cleaned mechanically, if porous, or with a solvent if nonporous. Glass may be cleaned with water containing a surfactant or with a solvent. Metals may also be cleaned with a solvent. In the latter case, apply the solvent with a clean, oilfree, lintfree cloth. Remove residual solvent with a fresh, clean dry cloth before it evaporates. Priming Sikasil Primers are not cleaning agents. Therefore clean the surface as described for Cleaning by the two cloths method. Subsequently: - Pour a small amount of primer onto a clean, lint-free, dry cloth and apply it in one operation. Never dip the cloths into the primer! - Only apply Sikasil Primers (esp. Sikasil Primer -790) in a thin layer, since otherwise the surface will be cracked and brittle and Sikasil silicone sealant may no longer bond properly. - Once the primer has been applied, it is essential that no more solvent gets onto the surface and that there is no further contamination. - Allow to dry for the time given below and then apply Sikasil silicone sealant within the flash-off mentioned. Sikasil Primer -790: - For metals e.g. aluminium, stainless steel, galvanized steel - For powder coatings, e.g. polyester, EP and PU coatings, PVDF coatings - Flash off time: min. 20 minutes, max. 2 hours Sikasil Primer -783: - For porous substrates e.g. concrete, aerated concrete and cement plaster - Flash off time: min. 30 minutes, max. 8 hours Application Conditions / Limits Substrate Temperature +5 C min. / +40 C max. Air Temperature +5 C min. / +40 C max. Substrate Humidity Dry Application Instructions Application Method / is ready to use. Tools After suitable joint and substrate preparation, the sealant is gunned into place and tooled with a spatula or suitable smoothing liquid. When tooling press the sealant to the joint flanks. Cleaning of Tools Clean all tools and application equipment with sealant remover / Sikasil Cleaner immediately after use. Hardened / cured material can only be mechanically removed. 4 4/6

Notes on Application / Elastic sealants must not be over painted! Sealant compatible coatings may Limits cover the joint sides to max. 1mm. The compatibility should be tested individually according to ASTM C1087. is compatible with many cured silicone sealants. Where two or more different sealants are used, allow the first to cure completely before applying the next. may not be used for structural glazing bonding. Use Sikasil SG-18, Sikasil SG-20 and Sikasil SG-500 instead. Do not use on pre-stressed polyacrylate and polycarbonate elements as it may cause environmental stress cracking (crazing). may not be used on natural stone, such as marble, granite and quartzite, as it may cause staining. Sikasil WS-355 is preferred here. Light-coloured should not be used on such substrates as neoprene or EPDM; as these may cause it to turn yellow. Technical service: Please contact your supplier for more details of available laboratory facilities, applications support and other technical services as well as comprehensive technical information and literature. Health and Safety Information Protective Measures To avoid rare allergic reactions, we recommend the use of protective gloves. Change soiled work clothes and wash hands before breaks and after finishing works. Since releases a volatile, aggressive substance on curing, ensure good ventilation indoors. If this substance is inhaled in high concentrations over a long period of time, irreversible health effects cannot be ruled out. Local regulations as well as health and safety advice on packaging labels must be observed. Details health and safety information as well as detailed precautionary measures e.g. physical, toxicological and ecological data can be obtained from the safety data sheet. Important Notes All technical data stated in this Product Data Sheet are based on laboratory tests. Actual data may vary due to changing conditions beyond our control. 5 5/6

Building Systems Legal Notes The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Sika Hongkong Ltd. Rm. 1507-12, 15/F., Block A, New Trade Plaza, 6 On Ping Street, Shatin, N.T. HONG KONG Tel +852 2686 8108 Fax +852 2645 3671 email marketing@hk.sika.com website www.sika.com.hk The product is manufactured under a HKQAA ISO 9001 / ISO 14001 certified quality / environmental management system. 6 6/6