ab Fluo-8 No Wash Calcium Assay Kit

Similar documents
Fluo-8 No Wash Calcium Assay Kit

Fluo-8 Medium Removal Calcium Assay Kit

ab MDR Assay Kit (Fluorometric)

Rhod-4 No Wash Calcium Assay Kit

ab Cell Viability Assay Kit Fluorometric Dual Green/Red

ab Proteasome 20S Activity Assay Kit (Fluorometric)

Cell Viability Assay Kit Fluorometric Near InfraRed

ab Generic Caspase Activity Assay Kit Fluorometric Green

Cell Viability Assay Kit Fluorometric Blue

ab JC-10 Mitochondrial Membrane Potential Assay Kit Flow Cytometry

Pyrophosphate Assay Kit (Fluorometric)

Universal Kinase Assay Kit (Fluorometric) For monitoring ADP formation, which is directly proportional to enzyme phosphotransferase activity

For the rapid, sensitive and accurate measurement of Lactate levels in various samples

Lysyl Oxidase Activity Assay Kit - Red Fluorescence

Xanthine Oxidase Assay Kit

ab Mammalian Cell Lysis Buffer 5X Instructions for Use For mammalian cell lysis.

For the rapid, sensitive and accurate measurement of Ferrous and/or Ferric ions in various samples.

For the rapid, sensitive and accurate measurement of Glutamate in various samples.

LDH-Cytotoxicity Assay Kit II

For the rapid, sensitive and accurate detection of MMP-1 inhibition by various compounds.

ab Beta Galactosidase Detection Kit (Fluorometric) Instructions for Use For monitoring β-galactosidase activity in cells.

Neutrophil Elastase Inhibitor Screening Kit

Alanine Transaminase Activity Assay Kit

Nitric Oxide Assay Kit (Fluorometric)

For the rapid, sensitive and accurate measurement of Histone Acetyltransferase activity in cell and tissue lysates.

For the rapid, sensitive and accurate measurement of Creatinine in various samples.

Total NAD and NADH Assay Kit (Colorimetric)

For the rapid, sensitive and accurate measurement of Citrate levels in various samples

For the rapid, sensitive and accurate measurement of Tyrosine in biological samples.

Glucose 6 Phosphate Dehydrogenase Assay Kit (Colorimetric)

Aspartate Aminotransferase Activity Assay Kit (Fluorometric)

ADP/ATP Ratio Assay Kit (Bioluminescent)

MMP Activity Assay Kit (Fluorometric - Red)

ab Fura-2 No Wash Calcium Assay Kit

Cell Viability Assay Kit (Bioluminescent)

ADP/ATP Ratio Assay Kit (Bioluminescent)

ab CytoPainter Live Cell Labeling Kit - Blue Fluorescence Instructions for Use

Iron Assay Kit. Catalog Number KA assays Version: 05. Intended for research use only.

Universal Methyltransferase Activity Assay Kit

For the rapid, sensitive and accurate measurement of Caspase 3 Activity in cell and tissue lysates.

Nuclear Condensation Assay Kit Green Fluorescence

ab Chromatin Condensation Assay Kit

Calcium Assay Kit. Technical Data Sheet. Product Information. Description. Storage. Materials not included

CytoPainter Cell Tracking Staining Kit Green Fluorescence

CytoPainter Cell Tracking Staining Kit Green Fluorescence

BD Ratiometric Calcium Assay Kit

Ratiometric Calcium Assay Kit

ab Complex IV Human Enzyme Activity Microplate Assay Kit

Human Growth Hormone Human ELISA Kit

FLIPR Calcium 6 Assay Explorer Kit (R8190) FLIPR Calcium 6-QF Assay Explorer Kit (R8192)

beta-secretase Activity Assay Kit

ab CytoPainter Mitochondrial Staining Kit - Green Fluorescence

ab CytoPainter Cell Plasma Membrane Staining Kit Deep Red Fluorescence

Universal Methyltransferase Activity Assay Kit (for HTP)

Asparaginase Activity Assay Kit

ab Thrombin Inhibitor Screening Assay Kit (Fluorometric)

ab CFSE Fluorescent Cell Labeling Kit

ab Plasmin Activity Assay Kit (Fluorometric)

ab CytoPainter Mitochondrial Staining Kit NIR Fluorescence

ab Factor VIIIa Activity Assay Kit (Fluorometric)

ab MTS Cell Proliferation Assay Kit (Colorimetric)

ab Factor IXa Activity Assay Kit (Fluorometric)

ab65327 Nitric Oxide Assay Kit (Fluorometric)

RayBio ApoSENSOR TM ATP Cell Viability Assay Kit

ab Cellular Reactive Detection Assay Kit (Red Fluorescence) Version 3c Last updated 24 August 2017

pan-caspase (Active) Red Staining Kit

RayBio Caspase-3 Colorimetric Assay Kit

ab Plasmin Inhibitor Screening Assay Kit (Fluorometric)

Renilla Luciferase Luminometric Assay Kit

pan-caspase (active) FITC Staining Kit

ab83371 Alkaline Phosphatase Assay Kit (Fluorometric)

RayBio HDAC-8 Inhibitor Screening Kit

ab PDE Activity Assay Kit (Colorimetric)

ab GFP ELISA Kit Instructions for Use For the quantitative measurement of GFP protein expression

ab CytoPainter MitoBlue Indicator Reagent

For the sensitive and accurate measurement of adenylate cyclase activity in cell extracts, tissue extracts and biological fluids.

RayBio Caspase Colorimetric Substrate Set II Plus

ab Factor Xa Inhibitor Screening Assay Kit (Fluorometric)

ab Glucose Uptake Assay Kit (Cell-based)

Testosterone Human ELISA Kit

Caspase-3 Assay Kit (Fluorometric)

ab83355 ATP Assay Kit (Colorimetric/ Fluorometric)

ab Thrombin Activity Assay Kit (Fluorometric)

ab Adenosylhomocysteinase (AHCY) Inhibitor Screening Assay Kit (Fluorometric)

RayBio Caspase-3 Inhibitor Drug Screening Kit

Ethanol Assay Kit (Colorimetric/Fluorometric) For the rapid, sensitive and accurate measurement of ethanol levels in various samples.

RayBio Caspase-3 Fluorometric Assay Kit

ab Calcium Detection Assay kit (Colorimetric)

Parvovirus B19 IgG Human ELISA Kit

Tissue Factor Human Chromogenic Activity Assay Kit

ab Nile Red Staining Kit 1

ab Cellular Reactive Detection Assay Kit (Deep Red Fluorescence) Version 3 Last updated 22 December 2016

For the rapid, sensitive and accurate measurement of apoptosis in various samples.

CytoPainter Cell Proliferation Staining Reagent Blue Fluorescence (Ex-405nm)

ab39412 Caspase 1 Assay Kit (Fluorometric)

For labelling sub-cellular organelles in tissue sections, cell cultures and cell free experiments using our proprietary Red fluorescence probe

ab CytoPainter Phalloidin-iFluor 594

Mitochondrial Aldehyde Dehydrogenase (ALDH2) Activity Assay Kit

Fluo-4 NW Calcium Assay Kits (F36205, F36206)

For identifying inhibitors and activators of mitochondrial biogenesis in adherent cultured cells.

Transcription:

ab112129 Fluo-8 No Wash Calcium Assay Kit Instructions for Use For detecting calcium in cells by using our proprietary fluorescence probe. This product is for research use only and is not intended for diagnostic use. 0

1

Table of Contents 1. Introduction 3 2. Protocol Summary 5 3. Kit Contents 6 4. Storage and Handling 6 5. Addittional Materials Required 6 6. Assay Protocol 7 7. Data Analysis 10 8. Troubleshooting 11 2

1. Introduction Abcam Fluo-8 Calcium Assay Kits provide homogeneous fluorescence-based assays for detecting intracellular calcium mobilization. Cells expressing a GPCR of interest that signals through calcium are pre-loaded with Fluo-8 which can cross cell membrane. Once inside the cell, the lipophilic blocking groups of Fluo-8 are cleaved by esterase, resulting in a negatively charged fluorescent dye that stays inside cells. Its fluorescence is greatly enhanced upon binding to calcium. When cells stimulated with agonists, the receptor signals the release of intracellular calcium, which significantly increase the fluorescence of Fluo-8. The characteristics of its long wavelength, high sensitivity, and >100 times fluorescence enhancement make Fluo-8 an ideal indicator for the measurement of cellular calcium. ab112129 provide an optimized assay method for monitoring the G- protein-coupled receptors and calcium channels. The assay can be performed in a convenient 96-well or 384-well microtiter-plate format and easily adapted to automation 3

Kit Key Features ab112129 Fluo-8 No Wash Calcium Assay Kit Increased Signal Intensity: Fluo-8 is a bright calcium indicator. Flexible Dye Loading: Dye loading at RT. Convenient: Formulated to have minimal hands-on time. No wash step needed. Versatile Applications: Compatible with many cell lines and targets without ligand or target interference. 4

2. Protocol Summary Summary for One 96-well Plate- Warning: Do not add additional probenecid... Prepare cells in growth medium with 0.5-1% FBS Add Fluo-8 dye-loading solution (100 µl/well/96-well plate or 25 µl/well/384-well plate) Incubate at room temperature for 1 hour Monitor the fluorescence intensity at Ex/Em = 490/525 nm Note: Thaw all the kit components to room temperature before starting the experiment. 5

3. Kit Contents Components Amount Component A: Flou-8 1 vial Component B: 10X Pluronic F127 Plus 1 ml Component C: HHBS 9 ml 4. Storage and Handling Keep at -20 C. Protect from light. 5. Additional Materials Required A 96 or 384-well microplate: Tissue culture microplate with black wall and clear bottom. A fluorescence microplate reader with a filter set of Ex/Em = 490/525 nm. HHBS (1X Hank s with 20 mm Hepes Buffer, ph 7.0). 100% DMSO. 6

6. Assay Protocol Note: This protocol is for one 96 - well plate. Warning: Do not add additional probenecid. A. Prepare Cells 1. For adherent cells: Plate cells overnight in growth medium with 0.5-1% FBS at 40,000 to 80,000 cells/well/100 µl for a 96-well plate or 10,000 to 20,000 cells/well/25 µl for a 384-well plate. 2. For non-adherent cells: Centrifuge the cells from the culture medium and then suspend the cell pellet in equal amount of HHBS and Fluo-8 dye-loading solution (see Step B.4 below) at 125,000 to 250,000 cells/well/100 µl for a 96-well poly-d lysine plate or 30,000 to 60,000 cells/well/25 µl for a 384-well poly-d lysine plate. Centrifuge the plate at 800 rpm for 2 minutes with brake off prior to the experiments. Note: Each cell line should be evaluated on an individual basis to determine the optimal cell density for the intracellular calcium mobilization. 7

B. Preparation of Fluo-8 dye-loading solution 1. Thaw all the kit components at room temperature before use. 2. Make Fluo-8 stock solution: Add 20 µl of DMSO into Fluo-8 (Component A) and mix them well. Note: 20 µl of Fluo-8 stock solution is enough for one plate. Unused Fluo-8 stock solution can be aliquoted and stored at < -20 o C for more than one month if the tubes are sealed tightly. Keep from light and avoid repeated freeze-thaw cycles. 3. Make 1X assay buffer: Add 9 ml of HHBS (Component C) into 1 ml of 10X Pluronic F127 Plus (Component B), and mix them well. Note: 10 ml of 1X assay buffer is enough for one plate. Aliquot and store un-used 1X assay buffer at < -20 o C. Keep from light and avoid repeated freeze-thaw cycles. 4. Make Fluo-8 dye-loading solution for one cell plate: Add 20 µl of Fluo-8 stock solution (from Step 2) into 10 ml of 1X assay buffer (from Step 3), and mix them well. This working solution is stable for at least 2 hours at room temperature. 8

C. Run Calcium Assay: 1. Add 100 µl/well (96-well plate) or 25 µl/well (384-well plate) of Fluo-8 dye-loading solution (from Step B.4) into the cell plate. Note: Alternatively, grow the cells in growth medium with 5-10% FBS to improve cell growth. In this case, it is important to replace the growth medium with HHBS buffer in order to minimize background fluorescence, and compound interference with serum. 2. Incubate the dye-loading plate in a cell incubator for 30 minutes, and then incubate the plate at room temperature for another 30 minutes. Note 1: If the assay requires 37 o C, perform the experiment immediately without further room temperature incubation. Note 2: If the cells can function well at room temperature for longer time, incubate the cell plate at room temperature for 1-2 hours. 3. Prepare the compound plates with HHBS or the desired buffer. 4. Run the calcium flux assay by monitoring the fluorescence intensity at Ex/Em = 490/525 nm. 9

7. Data Analysis Figure 1. Carbachol Dose Response was measured in HEK-293 cells with ab112129. HEK-293 cells were seeded overnight at 40,000 cells/100 µl/well in black wall/clear bottom 96-well plate. The cells were incubated with 100 µl of dye-loading solution using ab112129 for 1 hour at room temperature. Carbachol (50 µl/well) was added to achieve the final indicated concentrations. 10

8. Troubleshooting Problem Reason Solution Assay not working Unexpected results Assay buffer at wrong temperature Protocol step missed Plate read at incorrect wavelength Unsuitable microtiter plate for assay Measured at wrong wavelength Samples contain impeding substances Unsuitable sample type Sample readings are outside linear range Assay buffer must not be chilled - needs to be at RT Re-read and follow the protocol exactly Ensure you are using appropriate reader and filter settings (refer to datasheet) Fluorescence: Black plates (clear bottoms); Luminescence: White plates; Colorimetry: Clear plates. If critical, datasheet will indicate whether to use flat- or U-shaped wells Use appropriate reader and filter settings described in datasheet Troubleshoot and also consider deproteinizing samples Use recommended samples types as listed on the datasheet Concentrate/ dilute samples to be in linear range 11

Samples with inconsistent readings Lower/ Higher readings in samples and standards Unsuitable sample type Samples prepared in the wrong buffer Samples not deproteinized (if indicated on datasheet) Cell/ tissue samples not sufficiently homogenized Too many freezethaw cycles Samples contain impeding substances Samples are too old or incorrectly stored Not fully thawed kit components Out-of-date kit or incorrectly stored reagents Reagents sitting for extended periods on ice Incorrect incubation time/ temperature Incorrect amounts used Refer to datasheet for details about incompatible samples Use the assay buffer provided (or refer to datasheet for instructions) Use the 10kDa spin column (ab93349) or Deproteinizing sample preparation kit (ab93299) Increase sonication time/ number of strokes with the Dounce homogenizer Aliquot samples to reduce the number of freeze-thaw cycles Troubleshoot and also consider deproteinizing samples Use freshly made samples and store at recommended temperature until use Wait for components to thaw completely and gently mix prior use Always check expiry date and store kit components as recommended on the datasheet Try to prepare a fresh reaction mix prior to each use Refer to datasheet for recommended incubation time and/ or temperature Check pipette is calibrated correctly (always use smallest volume pipette that can pipette entire volume) 12

Problem Reason Solution Standard curve is not linear Not fully thawed kit components Pipetting errors when setting up the standard curve Incorrect pipetting when preparing the reaction mix Air bubbles in wells Concentration of standard stock incorrect Errors in standard curve calculations Use of other reagents than those provided with the kit Wait for components to thaw completely and gently mix prior use Try not to pipette too small volumes Always prepare a master mix Air bubbles will interfere with readings; try to avoid producing air bubbles and always remove bubbles prior to reading plates Recheck datasheet for recommended concentrations of standard stocks Refer to datasheet and re-check the calculations Use fresh components from the same kit For further technical questions please do not hesitate to contact us by email (technical@abcam.com) or phone (select contact us on www.abcam.com for the phone number for your region). 13

14

Abcam in the USA Abcam in Japan Abcam Inc Abcam KK 1 Kendall Square, Ste B2304 1-16-8 Nihonbashi Cambridge, Kakigaracho, MA 02139-1517 Chuo-ku, Tokyo USA 103-0014 Japan Toll free: 888-77-ABCAM (22226) Fax: 866-739-9884 Tel: +81-(0)3-6231-094 Fax: +81-(0)3-6231-0941 Abcam in Europe Abcam in Hong Kong Abcam plc Abcam (Hong Kong) Ltd 330 Cambridge Science Park Unit 225A & 225B, 2/F Cambridge Core Building 2 CB4 0FL 1 Science Park West Avenue UK Hong Kong Science Park Hong Kong Tel: +44 (0)1223 696000 Fax: +44 (0)1223 771600 Tel: (852) 2603-682 Fax: (852) 3016-1888 15 Copyright 2011 Abcam, All Rights Reserved. The Abcam logo is a registered trademark. All information / detail is correct at time of going to print.