Agilent InfinityLab Preparative Flow Cells for MWD & DAD

Similar documents
Agilent Max-Light Cartridge Cell Information for G4212A and G4212B DAD

Scale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system

TRACE 1300 and TRACE 1310 Gas Chromatographs Dual Detector Microfluidics Installation Guide

Agilent 1220 Infinity LC Mobile Upgrade Kit

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

Agilent 1260 Infinity RID User Manual. 9 Maintenance

Sanitary Pressure Regulators RHPS Series

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial

P600 Pressure Regulator

Clean Gas Filter. SF Series. Cartridge Type/Disposable Type IDFA IDFB IDH ID IDG IDK AMG AFF AM AMD AMH AME AMF ZFC SF SFD LLB AD GD SFC10

5000TOC Sensor Standard Operating Procedure

Quick Reference Guide. Supplies for CTC GC and HPLC Autosamplers

Cells and Calibration Standards

AVK 26 AVK UK Water Mains to Meter Offer & Price List 2017

KOBRA CELL Art. No. K01

Product data sheet DUMATHERM N Pro. for the automatic serial determination of NITROGEN

Maelstrom. Installation and Specification Guide

Transferring a Method from a Conventional 3.5 µm or 5 µm to an Agilent Poroshell 120 Column to Improve Analytical Speed and Resolution

Sioutas Cascade Impactor

Agilent Consumables Improve Performance with Shimadzu GC/MS

SCIEX Anion Analysis Kit For P/ACE MDQ and P/ACE MDQ plus Capillary Electrophoresis Systems. Instruction Guide

U-LAP. UTR-30 & UTR-70 Recipro Air Lappers Repair Manual. BORIDE Engineered Abrasives 2615 Aero Park Dr. Traverse City, MI

WARNINGS AND PRECAUTIONS

TRACE 1300 and TRACE 1310 Gas Chromatographs. NoVent Microfluidics. Installation Guide Revision A March 2013

Agilent 1260 Infinity Purification Solution

Electrical Isolation

ASI MODEL DM 100 SERIES DILUTING MODULES

Module. Table of Contents. Section 9. Module NOTE: This section applies to applicators with UM50 modules.

Determination of Asarinin in Xixin (Asari Radix Et Rhizoma)

Preparative, Pilot & Process Columns

A. Division 01: Administrative, procedural, and temporary work requirements apply to this section.

Content Page OPTIC Liners OPTIC 2 OPTIC 3 OPTIC-4 LINEX PHASER

Agilent 1200 Series Purification System. User Manual

Series SFA100/200/300

Polymer Block Cleaning Kit

INSTALLATION MANUAL MOSER STAINLESS STEEL KITCHEN FAUCET MODEL MANCHESTER

IC Equipment. Ultrafiltration Manual EN

E Spray Drying. industries and NEW markets. challenges. Meeting the. of new WELCOME TO DELAVAN

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

OPERATOR S SAFETY MANUAL

Caring for Turbo V Ion Source Electrodes

( ) IONPAC ATC-HC ANION TRAP COLUMN

Model No. BWTDWFK-TRIFLO.

order:

Emission Line

Part Description Image Part Number

Rosemount 405 Compact Orifice Primary Element

L104 PTFE L120 PTFE. Type S Gasket. applications. For use on ASME B 16.5 flanges. May be used for above ground or subsea

Sioutas Cascade Impactor

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

Agilent 1260 Infinity Bio-inert Quaternary LC

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Essential MOLECULAR SPECTROSCOPY PAGES EDITION THE CHROMATOGRAPHY & SPECTROSCOPY CATALOG

Standard and Low-Flow 100 PLUS Powder Feed Pumps

High-Throughput LC/MS Purification of Pharmaceutical Impurities

SO2 measurement on flue gas desulfurization systems. Instruction manual

PerkinElmer Supplies/Parts. GC Accessories. Autosampler Syringes


Media-Isolated Mag Plus Probe LPG-ISO Kit

SYSTEM 600 GENERAL MAINTENANCE AND ADJUSTMENT GUIDE

Industrial flue gas probes. Instruction manual

Inlet Duct System for a Cisco 6807 Part Number: DIRLC3210S17W

D MkII MLB Pack-Unpack Procedure READ THIS PROCEDURE BEFORE REMOVING LIGHTBAND FROM THE SHIPPING CONTAINER

INSTRUCTION MANUAL.

Agilent 1260 Infinity Bio-inert Quaternary LC

THE INSTALLING INSTRUCTION FOR CONCEALED TANK

F2000-B2B, F2000-B2M FILTRATION SYSTEM INSTRUCTION MANUAL

NEW OUTSIDE DIAMETER FUSED SILICA FOR AGILENT J&W CP AND VF GC COLUMNS

LK Wallbox UNI Push X16 V2

Application Note. Environmental. Agilent 1290 Infinity Binary LC. with ISET and fine-tuning. Agilent 1290 Infinity Binary LC.

SEMPELL HP PREHEATER PROTECTION VALVES TYPE AVS 4/5

VAREC 3600B/3650B SERIES PRESSURE OR VACUUM RELIEF VALVES INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

PIP PCEPA003 Process Analyzer System Field Installation Guidelines

CE Oligonucleotide Analysis Kit Instruction Manual

Agilent 1290 Infinity II LC

Product data sheet DUMATHERM. DUMATHERM - FAST NITROGEN DETERMINATION Automated system for fast nitrogen determination acc.

Multi-Piece Shower with Trench Drain

STANDARD COAXIAL CONNECTORS

INSTALLATION INSTRUCTIONS

Worcester Controls E51/52. Enviro-Safe High Integrity Flanged Ball Valves

Storage Cap. EPA Method 325 Fenceline Monitoring. Arrow Points Up. Sampling Protocol. Screen Cap

High Temperature Aging Cell Instruction Manual

Consumables for LEAP Systems: (April 2014)

Owners Manual Models: 200-RODI4-XXX. US Water Systems 4 Stage RO/DI System Installation and Maintenance Manual.

Typical Feed Water Heater Isolation System.

Clutch Installation Kinze row unit

Hollo-Bolt. Hollo-Bolt by Lindapter. Hollo-Bolt Options

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

Installation instructions. LORO-ATTIKASTAR siphonic drains

Varian Supplies/Parts. GC Accessories. Septum Nut. Merlin Microseal Kit

Datasheet Rev.4 Jan 2015 Orifice plate - Overview

Preference Slimline 5537 Utility Console I NSTALLATION GUIDE

BakeMax Dough Mini Moulder BMMDM02

FFTR1821QB6A FFTR1821QM6A FFTR1821QS6A FFTR1821QW6A

ZS880 Linear Shower Drain Installation Instructions

TERMS OF REFERENCE Supply and Delivery of Pre-Fabricated Wind Noise Reducing Systems (WNRS)

Cosasco Retractable System (Intermediate Pressure Access)

Johnson. We now offer a real step forward in reliability with our newly designed riser pipes.

User Manual Dialysis probe

Transcription:

Agilent InfinityLab Preparative Flow Cells for MWD & DAD Technical Note This technical note describes the preparative flow cells for the Agilent 1260 Infinity II DAD WR (G7115A) and Agilent 1260 Infinity II MWD (G7165A). Contents Choice of Flow Cells and Capillaries for Preparative HPLC 2 Parts Identification 4 Preparative Flow Cell - Stainless Steel 4 Install Capillary Kit on Preparative Flow Cell 6 Install the Leak Plane Insert 8 Remove and Install a Preparative Flow Cell 9 Agilent Technologies

Choice of Flow Cells and Capillaries for Preparative HPLC The choice of the preparative flow cells depends on the optical path length; the choice for the flow cell connection capillaries depends on the flow rate or system capillary i.d., respectively. Preparative flow cells: p/n Description G7115-60001 InfinityLab Preparative Flow Cell Quartz, 3 mm path length, 50 bar (5 MPa) G7115-60002 InfinityLab Preparative Flow Cell Quartz, 0.3 mm path length, 50 bar (5 MPa) G7115-60003 InfinityLab Preparative Flow Cell Quartz, 0.06 mm path length, 50 bar (5 MPa) G1315-60016 Prep flow cell SST - 3 mm, 120 bar (12 MPa) recommended flow rate up to 50 ml/min NOTE The preparative flow cell p/n G1315-60016 comes with pre-installed capillaries. Use this stainless steel flow cell for high-pressure applications with low flow rates. For the preparative flow cells p/n G7115-60001, G7115-60002, and G7115-60003, install the connection capillaries to the flow cell before installing the flow cell into the detector, see Install Capillary Kit on Preparative Flow Cell on page 6. 2

Connection capillaries: p/n Description 5500-1342 Capillary ST DAD 4 8 ml/min 5500-1343 Capillary ST DAD 15 40 ml/min 5500-1344 Capillary ST DAD 40 80 ml/min 5500-1345 Capillary ST DAD 80 200 ml/min NOTE Order two capillaries for each flow cell (except for p/n G1315-60016). When ordering the capillaries via detector capillary option, you only need to order the option number one time (the option triggers two capillaries automatically). 3

Parts Identification Preparative Flow Cell - Stainless Steel Item p/n Description G1315-60016 Prep flow cell SST - 3 mm, 120 bar (12 MPa) recommended flow rate: 50 ml/min 1 79883-22402 Window screw 2 5062-8553 Washer kit (10/pk) 3 79883-28801 Compression washer 4 79883-22301 Window holder 5 1000-0488 Quartz window 6 G1315-68711 Gasket BACK (PTFE), 2.3 mm hole, outlet side (12/pk) 7 G1315-68710 Gasket FRONT (PTFE), 1.3 mm hole, inlet side (12/pk) 8 Window assembly (comprises window screw, spring washers, compression washer, window holder and quartz window) 79883-68703 Window screw kit, includes 2 quartz windows, 2 compression washers, 2 window holders, 2 window screws and 10 washers G1315-68712 Cell repair kit STD includes window screw kit, 4 mm hexagonal wrench and seal kit 9 G1315-87305 Capillary SST, 250 mm length, 0.5 mm i.d., o.d. 0.9 mm with fittings for flow cell assembled 9a 5062-2418 1/16 fittings and ferrules 10/pk 10 G1315-27706 Cell body 11 G1315-84901 Clamp unit 12 G1315-84902 Handle for Clamp unit 13 0515-1056 Screw M 2.5, 4 mm lg for cell body/clamp 4

Figure 1 Prep Flow Cell - SST Parts NOTE Gaskets # 6 and #7 have different hole diameters. Figure 2 Orientation of Spring Washers 5

Install Capillary Kit on Preparative Flow Cell Tools required p/n Description 8710-2820 Flow Cell Capillary Tool Parts required p/n Description G7115-60001 InfinityLab Preparative Flow Cell Quartz, 3 mm path length, 50 bar (5 MPa) OR G7115-60002 InfinityLab Preparative Flow Cell Quartz, 0.3 mm path length, 50 bar (5 MPa) OR G7115-60003 InfinityLab Preparative Flow Cell Quartz, 0.06 mm path length, 50 bar (5 MPa) 5500-1342 Capillary ST DAD 4 8 ml/min OR 5500-1343 Capillary ST DAD 15 40 ml/min OR 5500-1344 Capillary ST DAD 40 80 ml/min OR 5500-1345 Capillary ST DAD 80 200 ml/min 6

1 Install the inlet and outlet capillaries to the flow cell body using the Flow Cell Capillary Tool. 2 Bend the capillaries as shown. Bend the outlet capillary first, and then the inlet capillary. Inlet capillary Outlet capillary 3 Install the flow cell to the detector, see Remove and Install a Preparative Flow Cell on page 9. 7

Install the Leak Plane Insert When When using G7115A or G7165A detector with a preparative flow cell Parts required p/n Description G7115-45010 Leak Plane Insert 1 Slide the leak plane insert into the opening in the detector housing below the optical unit. 2 Push the leak plane insert in until it is flush with the housing. 3 Install the preparative flow cell to the detector, see Remove and Install a Preparative Flow Cell on page 9. 8

Remove and Install a Preparative Flow Cell When Tools required If an application needs a different type of flow cell or the flow cell needs repair. Description Wrench, 1/4 inch for capillary connections Parts required # p/n Description 1 G7115-60001 InfinityLab Preparative Flow Cell Quartz, 3 mm path length, 50 bar (5 MPa) OR 1 G7115-60002 InfinityLab Preparative Flow Cell Quartz, 0.3 mm path length, 50 bar (5 MPa) OR 1 G7115-60003 InfinityLab Preparative Flow Cell Quartz, 0.06 mm path length, 50 bar (5 MPa) OR 1 G1315-60016 Prep flow cell SST - 3 mm, 120 bar (12 MPa) 2 5022-2133 High Flow union, ST, no fitting Preparations NOTE Turn the lamp(s) off. The preparative flow cell p/n G1315-60016 comes with pre-installed capillaries. Use this stainless steel flow cell for high-pressure applications with low flowrates. For the preparative flow cells p/n G7115-60001, G7115-60002, and G7115-60003, install the capillaries to the flow cell before installing the flow cell into the detector, see Install Capillary Kit on Preparative Flow Cell on page 6. NOTE Use High Flow union, ST, no fitting (5022-2133) on the flow cell holder instead of standard unions. NOTE The lamp house cover includes a magnet. 9

1 Open the doors. 2 Grab the lamp cover and pull it off (it is fixed by two magnets in the center of the cover). 3 Open the flow cell door. 10

4 Disconnect the flow cell inlet capillary (top) from the union. 5 Disconnect the waste tubing (bottom) from the union. 11

6 Loosen the thumb screw (1.) and remove the flow cell outlet capillary (bottom) with the union (2.). 7 Remove the flow cell while pressing the flow cell holder. NOTE The label attached to the flow cell provides information on part number, path length, and maximum pressure. 12

8 Insert the flow cell while pressing the flow cell holder. 9 Insert the flow cell capillaries into the union holder (top is inlet, bottom is outlet). 13

10 Tighten the thumb screw. 11 Reconnect the waste tubing (bottom) to the union. Establish a flow and check for leaks. NOTE To check for leaks, establish a flow and observe the flow cell (outside of the cell compartment) and all capillary connections. 14

12 Close the flow cell door. 13 Slide the lamp cover into the top position of the metal front and press the lamp cover completely in until it clicks. 15

14 Close the doors. 15 Perform a Wavelength Verification and Calibration or a Holmium Oxide Test to check the correct positioning of the flow cell. *G7115-90110 * *G7115-90110 * G7115-90110 Part Number: G7115-90110 Rev. B Edition: 12/2017 Printed in Germany Agilent Technologies, Inc 2017 Agilent Technologies, Inc Hewlett-Packard-Strasse 8 76337 Waldbronn, Germany