IBC Compliant Seismic Rated Isolators

Similar documents
SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION ISOLATION

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NATIONWIDE SAN ANTONIO SALES & SERVICE CENTER

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions.

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Houston First Corporation Package 1

DIVISION 20 GENERAL SECTIONS FOR PLUMBING, FIRE SUPPRESSION & HVAC SECTION VIBRATION ISOLATORS

SECTION VIBRATION AND SEISMIC CONTROL FOR PLUMBING

SUMMARY OF ADDENDUM NUMBER FOUR

SECTION VIBRATION ISOLATION

.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM)

SEISMIC RESTRAINT SYSTEM

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

KINETICS TM. Restrained Spring Isolators Model FLSS 1 and 2

JAMISON SOUND DOOR SPECIFICATIONS VERTICAL SLIDING SOUND REDUCTION DOOR - STC 53 POWERED OPERATION

C. OSHPD: Office of Statewide Health Planning and Development for the State of California.

VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING

DARTMOUTH COLLEGE DESIGN September 15, 2004 &CONSTRUCTION GUIDELINES

Installation Instructions

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

ADDENDUM NUMBER 10 TO THE PLANS AND SPECIFICATIONS FOR

Mounting Bases and Vibration Isolation. for Greenheck Centrifugal Fans GREENHECK

Division 15 VIBRATION ISOLATION AND SILENCERS Section Page 1 of 6

SECTION STRUCTURE MOUNT RAILING SYSTEM

Pipe Riser Isolation Selection Guide

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

Product Guide Specification

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC EQUIPMENT

WALL MOUNTED ARTICULATING JIB CRANE

SECTION ROOF EDGE SAFETY RAILING SYSTEM

TITEN HD Heavy Duty Screw Anchor for Concrete & Masonry

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

PRODUCT EVALUATION Effective Date: June 1, 2013 GDR-39

Table of Contents... 1, 2. (EF) Equipment Floor... VISR EF 102 Water Heater VISR EF 104 Chiller VISR EF 105 End Suction Pump...

DB10 BLTD C10 Pipe Support. Description. Manufacturer Information BOLTED FRAMING GTIN UPC

SECTION NOISE AND VIBRATION CONTROL FOR HVAC PIPING AND EQUIPMENT

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Glenlake Modular Railing System

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

PRODUCT EVALUATION Effective Date: June 1, 2013 GDR-40

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS

05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES

KINETICS Seismic Design Manual

Expansion Joint Covers (079513)

Interior Hangers. Application

VIBRATION TRANSMISSIBILITY CURVE FOR AN ISOLATED SYSTEM

ERS2010 ERSW2010. Users Manual. Seismic Restraint System

SECTION STRUCTURAL METAL FRAMING

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

A joint reliance VIBRATION ISOLATOR NOISE & VIBRATION CONTROL PRODUCT VI-0107

This guide can be used to prepare a specification for incorporating wall bracket jib cranes into a competitively bid construction project.

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.

INSTALLATION MANUAL RECTANGULAR COLUMN

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Summit tm Modular Railing System

SPECIFICATION FOR CI DECKING SYSTEM

Trex Commercial Products page Decorative Metal Railing


SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION NON-PENETRATING PORTABLE ROOFTOP SUPPORTS AND WALKWAYS. For best results, display hidden notes to specifier.

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Monaco tm Modular Railing System

SECTION PREFABRICATED SHOWER COMPARTMENTS

Product Guide Specification

METAL LADDERS (LADDER SAFETY GATE FALL PROTECTION)

Important Instructions

Concrete Inserts. B Adjustable Metal Deck Ceiling Bolt

2004 Specifications CSJ SPECIAL SPECIFICATION DIRECT FIXATION TRACK CONSTRUCTION

SECTION ORNAMENTAL ALUMINUM RAILING

INTRODUCTION DISC BEARINGS

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

1.02 RELATED SECTIONS: Water supply piping, water use piping, electrical, irrigation, foundations, site plans.

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Com-Tray. Under Floor

Fig Beam Clamp Retaining Strap (B-Line B3367)

TERRATORQUE HELICAL ANCHORS AND HELICAL PILING PRODUCT CATALOG

SECTION VIBRATION ISOLATION FOR PLUMBING PIPING AND EQUIPMENT

HIGH MAST CAMERA POLE ASSEMBLY GENERAL

Code Compliance Research Report CCRR-0225

H D P SOLID PHENOLIC FLOOR BRACED COMPARTMENTS SECTION FB TOILET PARTITIONS

SECTION COLD-FORMED METAL FRAMING

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

Expansion Joint Covers

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

SPECIFICATION FOR PERMANENT BEAM GRANDSTAND WITH INTERLOCK WELDED DECK SYSTEM

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

SECTION ORCHESTRA PIT FILLER

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

METALWORKS RH215 Faceted Custom Hook-on Panels

GENERAL SPECIFICATION FOR GI DECKING SYSTEM

Transcription:

ISOLATORS IBC Compliant Seismic Rated Isolators Features & Benefits Rugged steel housing is designed to handle high wind and seismic forces. Housing serves as blocking during equipment erection. Top plate may be welded or bolted to equipment - allowing flexible design options. Housing heights are identical within each series. Easily accessible bolt holes permit simplified installation. Isolators manufactured on robotic welders to maintain consistent quality. Powder coated housings and springs offer outstanding corrosion resistance. Springs are easily accessed for replacement if loads change. Color-coded springs permit proper identification of load capacity and simple inspection. Elastomeric acoustical cup allows for better vibration isolation. 3/8 spacer block allows for ease of installation by maintaining the installed height of the equipment and setting the proper air gap for seismic code compliance.. Applications General industrial equipment HVAC equipment and fan assemblies Pumps, chillers and cooling towers Condensing units The MS, MS, MSS & MSS Series Isolators have been Generator sets Planning and Development (OSHPD) All MS Series Isolators are manufactured using modern robotic welders. The standard finish on the housings and springs is powder coating and all hardware within the mounting is zinc electro-plated. The housings can also be ordered as hot dipped galvanized for superior corrosion resistance. 010 The VMC Group Toll Free:1-800-LOW-VIBE www.thevmcgroup.com 113 Main Street, PO Box 70, Bloomingdale, NJ 0703, Tel: 973/838-1780 Fax: 973/9-830 11930 Brittmoore Park Drive, Houston, TX 7701 Tel: 713/66-0003 Fax: 713/66-1355 Aeroflex International Isolators Amber/Booth Korfund Dynamics Vibration Mountings & Controls

ISOLATORS IBC Compliant Seismic Rated Isolators The VMC Group s next generation seismic mounts, the MS and MSS series isolators, combine our open spring mountings within a rugged welded seismically rated steel housing. To minimize the code required seismic loads on the isolated equipment, the housing is designed to limit equipment motion to ¼ in horizontal directions due to wind or seismic loads. The MS style isolator has internal spring adjustment while the MSS type incorporates an external adjustment bolt that also acts as a single point attachment to the equipment. Both isolators are designed to maintain low profiles similar to that of our non-seismic vibration isolators and both are available with 1 and deflection springs. Each style of mount has a load range from 50 lbs. to 6,500 lbs. The top housing incorporates seismic restraint bolts that pass through the lower housing and are protected in all directions by an elastomeric bushing. Combined, the restraint bolts and bushings act as the internal snubbing devices for the isolator. To achieve accurate installation heights, The VMC Group has incorporated an installation spacer between the lower and upper housing. After the equipment is installed and the isolators are properly adjusted, there will be no difference between the installed and operating heights. For the MS style isolator, mechanical equipment can be positively attached to the top housing by utilizing the pre-drilled bolt holes or by welding directly to the housing. Mechanical equipment is attached to the MSS style product by using the adjustment bolt of the isolator to fasten to the equipment s designated mounting locations. Low frequency T-Series steel springs are located within the housing and are seated in an elastomeric acoustical cup that provides high frequency attenuation and eliminates metal-to-metal contact. The spring and cup design allows for easy replacement or changing of springs when required and all springs are color-coded for ease of identification in the field. The lower housing incorporates an oversized base plate that spreads the anchor bolt over a wider area this is specifically designed to increase seismic restraint capability. As an additional benefit, ease of installation is also achieved by allowing easy access to the anchor bolts. These isolators are designed for installations in either concrete or steel and the base plates are pre-drilled with mounting holes to accommodate attachment to either. All MS and MSS series isolators are manufactured using modern robotic welders. The standard finish on the housings and springs is powder coating and all hardware within the mount is zinc electroplated. The housings can also be furnished as hot dipped galvanized for superior corrosion resistance. MS STYLE ISOLATOR 010 The VMC Group Toll Free:1-800-LOW-VIBE www.thevmcgroup.com 113 Main Street, PO Box 70, Bloomingdale, NJ 0703, Tel: 973/838-1780 Fax: 973/9-830 11930 Brittmoore Park Drive, Houston, TX 7701 Tel: 713/66-0003 Fax: 713/66-1355 0108-100-06 REV 1 01/10 MSS STYLE ISOLATOR Aeroflex International Isolators Amber/Booth Korfund Dynamics Vibration Mountings & Controls

7/8 7 1/ CONCRETE ( TYP) 1/ 6 1/ 7/8 7/8 1/ (BASE PLATE) STEEL ( TYP) (VIEW CUT AWAY 5/8 REMOVABLE ADJUSTING BOLT 3/8 GAP STEEL SHIM (REMOVE AFTER SPRING ADJUSTMENT) (1/) 1/ - 3/8 SNUBBER 1 3 5 7 6 1/8 FREE & OPERATING HEIGHT CUP 1/ LIMIT STOP (3/8) 6 8 9 8 NOTES: 1. ALL DIMENSIONS ARE IN INCHES, INTERPRET PER ANSI Y1.. STANDARD FINISH: HOUSING - POWDER COAT (COLOR:BLACK), SPRING - POWDER COAT (COLOR: SEE TABLE), HARDWARE ZINC-ELECTROPLATE. 3. EQUIPMENT MUST BE BOLTED OR WELDED TO THE TOP PLATE TO MEET ALLOWABLE SEISMIC RATINGS.. ISOLATOR BASE PLATE MUST BE ANCHORED TO STEEL EITHER BY WELDING OR WITH MIN () 5/8 DIA A35 BOLTS, OR IT MUST BE ANCHORED TO CONCRETE WITH () 5/8 DIA ANCHORS WITH ALLOWABLE LOADS OF 3600 POUNDS SHEAR AND 100 POUNDS TENSION OR AS DIRECTED BY. 5. ALL SPRINGS ARE DESIGNED FOR 50% OVERLOAD CAPACITY. 6. REFER TO SHEET OF FOR INSTALLATION INSTRUCTIONS. MODEL MSS-1E VIBRATION ISOLATOR WITH INTEGRAL SEISMIC RESTRAINT AND EXTERNAL ADJUSTMENT FOR 1" DEFLECTION ISOLATOR SELECTIONS LOC 1: LOC : LOC 3: LOC : LOC 5: LOC 6: LOC 7: LOC 8: CUSTOMER EQP'T. TAG: NOTE: MATERIAL SHOWN IS FOR (1) SET. Bloomingdale, NJ 0703 Houston, TX 7701 1 OF

1 1/ 11 1/ 13/16 DIA HOLE FOR CONCRETE ( TYP) 1/ 6 1/ 7/8 7/8 7 1/8 (BASE PLATE) STEEL ( TYP) (VIEW CUT AWAY 5/8 REMOVABLE ADJUSTING BOLT IN TOP VIEW 3/ 3/8 GAP COMPRESSION PLATE STEEL SHIM (REMOVE AFTER SPRING ADJUSTMENT) (1/) 1/ - 3/8 SNUBBER 1 3 5 7 6 1/8 FREE & OPERATING HEIGHT CUP 1/ LIMIT STOP (3/8) 1 1/ 8 6 8 NOTES: 1. ALL DIMENSIONS ARE IN INCHES, INTERPRET PER ANSI Y1.. STANDARD FINISH: HOUSING - POWDER COAT (COLOR:BLACK), SPRING - POWDER COAT (COLOR: SEE TABLE), HARDWARE ZINC-ELECTROPLATE. 3. EQUIPMENT MUST BE BOLTED OR WELDED TO THE TOP PLATE TO MEET ALLOWABLE SEISMIC RATINGS.. ISOLATOR BASE PLATE MUST BE ANCHORED TO STEEL EITHER BY WELDING OR WITH MIN () 5/8 DIA A35 BOLTS, OR IT MUST BE ANCHORED TO CONCRETE WITH () 3/ DIA ANCHORS WITH ALLOWABLE LOADS OF 5900 POUNDS SHEAR AND 3900 POUNDS TENSION OR AS DIRECTED BY. 5. ALL SPRINGS ARE DESIGNED FOR 50% OVERLOAD CAPACITY. 6. REFER TO SHEET OF FOR INSTALLATION INSTRUCTIONS. MODEL MSS-1E VIBRATION ISOLATOR WITH INTEGRAL SEISMIC RESTRAINT AND EXTERNAL ADJUSTMENT FOR 1" DEFLECTION ISOLATOR SELECTIONS LOC 1: LOC : LOC 3: LOC : LOC 5: LOC 6: LOC 7: LOC 8: CUSTOMER EQP'T. TAG: NOTE: MATERIAL SHOWN IS FOR (1) SET. Bloomingdale, NJ 0703 Houston, TX 7701 1 OF

1. READ INSTRUCTIONS IN THEIR ENTIRETY BEFORE BEGINNING INSTALLATION.. ISOLATORS ARE SHIPPED FULLY ASSEMBLED AND ARE TO BE POSITIONED IN ACCORDANCE WITH THE SUBMITTAL DRAWINGS OR AS OTHERWISE RECOMMENDED. 3. SET ISOLATORS ON FLOOR, HOUSEKEEPING PAD, OR SUB-BASE, ENSURING THAT ALL ISOLATOR CENTERLINES MATCH THE EQUIPMENT MOUNTING HOLES. THE VMC GROUP RECOMMENDS THAT THE ISOLATOR BASE PLATES ("B") BE INSTALLED ON A LEVEL SURFACE. SHIM OR GROUT AS REQUIRED, LEVELING ALL ISOLATOR BASE PLATES AT THE SAME ELEVATION (1/-INCH MAXIMUM DIFFERENCE CAN BE TOLERATED).. ANCHOR ALL ISOLATORS TO THE FLOOR, HOUSEKEEPING PAD, OR SUB-BASE USING THRU HOLES ("C") FOR CONCRETE OR ("D") FOR STEEL AS REQUIRED. USE ANCHORS MEETING THE DESIGN REQUIREMENTS SPECIFIED ON SHEET 1 OF. WELDING TO STEEL IS PERMITTED PROVIDING THE WELD ACHIEVES THE REQUIRED STRENGTH. 5. ISOLATORS ARE SHIPPED TO THE JOBSITE WITH () REMOVABLE SPACER SHIMS BETWEEN THE TOP PLATE AND THE HOUSING. THESE SHIMS MUST BE IN PLACE WHEN THE EQUIPMENT IS POSITIONED OVER THE ISOLATORS. 6. WITH ALL SHIMS IN PLACE, REMOVE ADJUSTING BOLT "G", AND SET ASIDE. KEEP THE NUT "H" SCREWED ONTO THE ADJUSTING BOLT. PLACE THE MACHINE OR EQUIPMENT ONTO TOP PLATE "A", ALIGNING THE EQUIPMENT MOUNTING HOLE WITH THE TAPPED HOLE IN THE TOP PLATE. REATTACH THE ADJUSTING BOLT BY BOLTING THROUGH THE EQUIPMENT MOUNTING HOLE INTO THE TAPPED HOLE OF THE ( Cont.) 6. (Cont.) ISOLATOR. TURN THE ADJUSTING BOLT UNTIL IT STARTS TO COMPRESS THE SPRING. LEAVE NUT "H" AT THE TOP OF THE ADJUSTING BOLT, LEAVING ROOM FOR ADJUSTING THE ISOLATOR PER STEP 9. 7. THE ADJUSTMENT PROCESS CAN ONLY BEGIN AFTER THE EQUIPMENT OR MACHINE IS AT ITS FULL OPERATING WEIGHT. 8. BACK OFF EACH OF THE () OR () LIMIT STOP LOCKNUTS ("F") PER ISOLATOR 1/- TO 3/8-INCH. 9. ADJUST EACH ISOLATOR IN SEQUENCE BY TURNING ADJUSTING BOLT(S) "G" ONE FULL CLOCKWISE TURN AT A TIME. REPEAT THIS PROCEDURE ON ALL ISOLATORS, ONE AT A TIME. CHECK THE LIMIT STOP LOCKNUTS ("F") PERIODICALLY TO ENSURE THAT CLEARANCE BETWEEN THE WASHER AND RUBBER GROMMET IS MAINTAINED. STOP ADJUSTMENT OF AN ISOLATOR ONLY WHEN THE TOP PLATE ("A") HAS RISEN JUST ABOVE THE SHIM. 10. REMOVE ALL SPACER SHIMS. 11. FINE ADJUST ISOLATORS TO LEVEL EQUIPMENT. 1. ADJUST ALL LIMIT STOP LOCKNUTS ("F") PER ISOLATOR TO OBTAIN 3/8-INCH GAP. THE LIMIT STOP NUTS MUST BE KEPT AT THIS 3/8-INCH GAP TO ENSURE UNIFORM BOLT LOADING DURING UPLIFT (AS IN THE CASE WHEN A COOLING TOWER IS DRAINED). 13. INSTALLATION IS COMPLETE. ("H") ("G") (EQUIPMENT) ("A") ("A") GROMMET 1/ - 3/8 WASHER ("F") ("F") ("B") ("C") ("D") ("C") INSTALLATION INSTRUCTIONS SERIES MSS AND MSS SEISMIC ISOLATORS Bloomingdale, NJ 0703 Houston, TX 7701 OF