QuantiFluor ONE dsdna System

Similar documents
QuantiFluor RNA System

QuantiFluor dsdna System

Rapid, Accurate and Flexible DNA Quantitation Using the QuantiFluor dsdna System on the MANTIS Liquid Handler

ReliaPrep RNA Clean-Up and Concentration System

Automated QuantiFluor dsdna and QuantiFluor ONE dsdna Systems Setup Protocol for the Tecan Freedom EVO Workstation

Automated Genomic DNA Isolation from Oragene Saliva Samples using the Tecan Freedom EVO -HSM Workstation

Automated Genomic DNA Isolation from Buffy Coat Samples Using the Tecan Freedom EVO -HSM Workstation

ReliaPrep 96 gdna Miniprep HT System INSTRUCTIONS FOR USE OF PRODUCTS A2670 AND A2671.

PowerSeq Quant MS System

ReliaPrep DNA Clean-Up and Concentration System

ProNex DNA QC Assay Calibration Kit, 7500

ReliaPrep FFPE gdna Miniprep System

TECHNICAL MANUAL. SwabSolution Kit. Instructions for Use of Product DC8271. Revised 9/16 TMD037

Quant-iT dsdna Broad-Range Assay Kit

Maxwell RSC Buffy Coat DNA Kit

Differex System For Use With the Differex Magnet

Maxwell RSC Buccal Swab DNA Kit

Maxwell RSC Stabilized Saliva DNA Kit

Maxwell RSC Blood DNA Kit

ReliaPrep gdna Tissue Miniprep System

Quantos Cell Proliferation Assay Kit

Maxwell CSC DNA FFPE Kit

Maxwell RSC Whole Blood DNA Kit

A Picofluor method for RNA quantitation using RiboGreen

PowerPlex 5-Dye Matrix Standards, 3100/3130

ReliaPrep mirna Cell and Tissue Miniprep System

Maxwell RSC Stabilized Saliva DNA Kit

Cell Proliferation Assay Kit

PowerPlex 4C Matrix Standard

Laboratory protocol for manual purification of DNA from whole sample

DNA Purification Magnetic Beads

Maxwell 16 LEV Blood DNA Kit and Maxwell 16 Buccal Swab LEV DNA Purification Kit

GoTaq 1-Step RT-qPCR System

Best Quantification Practices with the Agilent 5200 Fragment Analyzer System

SpectraMax Quant AccuClear Nano

Maxwell RSC Blood DNA Kit

GoTaq 2-Step RT-qPCR System

GoTaq 2-Step RT-qPCR System

Maxwell 16 FFPE Plus LEV DNA Purification Kit

Introduction. Technical Note

CellTox Green Cytotoxicity Assay

Automated CellTiter-Blue Cell Viability Assay Protocol Automated Protocol #EP015

Plexor HY System for the Applied Biosystems 7500 and 7500 FAST Real-Time PCR Systems

Automated Caspase-Glo Assays Protocol

SpectraMax Quant AccuBlue Pico dsdna Assay Kit

Accurately and reproducibly quantify as little as 20 fg of human DNA using real-time PCR.

Identity Automation qpcr Setup Protocol for the PowerQuant and Plexor HY Systems on the Beckman Coulter Biomek NX P Workstation

Maxwell RSC Cell DNA Purification Kit

Accurately and reproducibly quantify as little as 20 fg of human DNA using real-time PCR.

Maxwell RSC Viral Total Nucleic Acid Purification Kit

RayBio Genomic DNA Magnetic Beads Kit

Amplicon Library Preparation Method Manual. GS FLX Titanium Series October 2009

Human IgG ELISA Quantitation Set

Identity Automation qpcr Setup Protocol for the PowerQuant and Plexor HY Systems on the Beckman Coulter Biomek 4000 Workstation

ONE-Glo + Tox Luciferase Reporter and Cell Viability Assay

Dog IgG1 ELISA Quantitation Set

High specificity and sensitivity for fungal DNA allows reliable quantification in a background of nonfungal. Contents

Accurately and reproducibly quantify as little as 20 fg of bacterial DNA using real-time PCR.

Maxwell FSC DNA IQ Casework Kit

GoTaq Probe 2-Step RT-qPCR System

Nitric Oxide Assay Kit (Fluorometric)

phab Amine and Thiol Reactive Dyes

Purification of Concentrated, High-Quality RNA from Cells and Tissues

Identity Automation Differex System Protocol for the Beckman Coulter Biomek 4000

Maxwell RSC System. Next Generation Automated Purification and Quantitation

phab Amine and Thiol Reactive Dyes

Product Insert 1 1 Quantified RNA Standards are provided as 100 ng/µl, 10 ng/µl, 1 ng/µl, 100 pg/µl, 10 pg/µl and 1 pg/µl

E.Z.N.A. FFPE RNA Kit. R preps R preps R preps

PowerMag DNA Clean-Up Kit

Human Serum Albumin (HSA) ELISA Quantitation Kit. Manual

Quick and easy 7 minute protocol to select for 300 bp, 200 bp, 150 bp, 100 bp, 50 bp DNA fragments or perform a double size selection

Quick and easy 7 minute protocol to select for 300 bp, 200 bp, 150 bp, 100 bp, 50 bp DNA fragments or perform a double size selection

E.Z.N.A. mirna Kit. R preps R preps R preps

ViaFect Transfection Reagent

Mouse OVA IgG1 ELISA. Catalog Number M046072

TECHNICAL MANUAL. HDAC-Glo 2 Assay. Instructions for Use of Product G9590. Revised 11/17 TM406

ISOLATE II Blood DNA Kit. Product Manual

Data Sheet. PD-1[Biotinylated]:PD-L2 Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Gel Extraction Mini Spin Column Kit. UltraPrep Gel-Ex. Purification of DNA fragments and plasmids from agarose gels

Mouse Collagen Type III ELISA

Maxwell RSC RNA FFPE Kit

AssayMax Human Transferrin ELISA Kit

Cell-Free Protein Expression Kit

Complete protocol in 110 minutes Enzymatic fragmentation without sonication One-step fragmentation/tagging to save time

Human Serum Albumin (HSA) ELISA Quantitation Kit. Manual

TruePrime Single Cell WGA Kit

Bovine MALACT ELISA Kit

Maxwell 16 Viral Total Nucleic Acid Purification Kit

Measuring cell proliferation using the CyQUANT Cell Proliferation Assay with SpectraMax Microplate Readers

Identity Automation DNA Normalization and PowerPlex Setup Protocol for the Tecan Freedom EVO Workstation

Human Haptoglobin ELISA Quantitation Kit. Manual

PD-1 [Biotinylated] : PD-L1 Inhibitor Screening ELISA Assay Pair

Maxwell 16 LEV Plant RNA Kit

mirna Purification from Plant Tissues: Corn, Soybean and Arabidopsis

Measure-iT Thiol Assay Kit (M30550)

MD60002 MD MD62002

UV-Induced DNA Damage ELISA (CPD Quantitation)

GoTaq Probe qpcr Master Mix

GoTaq Probe qpcr Master Mix

Plant DNA/RNA Extraction Kit. User Manual

Transcription:

TECHNICAL MANUAL QuantiFluor ONE dsdna System Instructions for Use of Products E4871 and E4870 Revised 6/17 TM405

QuantiFluor ONE dsdna System All technical literature is available at: www.promega.com/protocols/ Visit the web site to verify that you are using the most current version of this Technical Manual. E-mail Promega Technical Services if you have questions on use of this system: techserv@promega.com 1. Description... 2 2. Product Components and Storage Conditions... 2 3. Protocol for Quantitating dsdna in a Single Tube Using the Quantus Fluorometer... 3 4. Protocol for Quantitating dsdna in Multiwell Plates... 5 5. Troubleshooting... 8 6. Interfering Compounds... 11 7. Handling and Disposal... 11 8. Composition of Buffers and Solutions... 11 9. Tips for Pipetting Small Volumes... 12 10. Related Products... 12 11. Summary of Changes... 13 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 1 www.promega.com TM405 Revised 6/17

1. Description The QuantiFluor ONE dsdna System (a) contains a fluorescent DNA-binding dye (504nm Ex /531nm Em ) that can sensitively quantitate small amounts of double-stranded DNA (dsdna) in a purified sample. The assay is highly selective for dsdna over other nucleic acids and is linear over a range of 0.2 400ng of dsdna input (0.2 400ng/µl from 1µl of original sample). The dye-based system provides the QuantiFluor ONE dsdna Dye and DNA standard for quick quantitation without the need for preparing a working solution by diluting the dye. Simply add standards and unknown samples to the dye, and read on a fluorometer. The QuantiFluor ONE dsdna System can be used with any single-tube fluorometer (e.g., Quantus Fluorometer [see Section 3]) or may be scaled up for use in instruments that can read multiwell plates (e.g., GloMax Discover System [see Section 4]) at the appropriate excitation and emission wavelengths. 2. Product Components and Storage Conditions PRODUCT SIZE CAT.# QuantiFluor ONE dsdna System 100 reactions E4871 This system contains sufficient reagents for 100 assays at a reaction volume of 200μl. Includes: 1 20ml QuantiFluor ONE dsdna Dye 80μg QuantiFluor ONE Lambda DNA (400μg/ml) 10ml 1X TE Buffer (ph 7.5) PRODUCT SIZE CAT.# QuantiFluor ONE dsdna System 500 reactions E4870 This system contains sufficient reagents for 500 assays at a reaction volume of 200μl. Includes: 5 20ml QuantiFluor ONE dsdna Dye 400μg QuantiFluor ONE Lambda DNA (400μg/ml) 25ml 1X TE Buffer (ph 7.5) Storage Conditions: Store QuantiFluor ONE dsdna Dye and QuantiFluor ONE Lambda DNA at 30 C to +10 C. Store the 1X TE Buffer (ph 7.5) at 30 C to +30 C. See Section 7, Handling and Disposal, for instructions on the handling and disposal of QuantiFluor ONE dsdna Dye. 2 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 TM405 Revised 6/17 www.promega.com

3. Protocol for Quantitating dsdna in a Single Tube Using the Quantus Fluorometer Materials to Be Supplied by the User nuclease-free water thin-walled 0.5ml PCR tubes (Cat.# E4941 or Axygen Cat.# PCR-05-C) Quantus Fluorometer (Cat.# E6150) optional: K562 Genomic DNA (Cat.# E4931) Quantitation of unknown samples requires comparison to a dsdna standard. Prepare a standard using the QuantiFluor ONE Lambda DNA, or a DNA of similar molecular weight to your sample of interest. The QuantiFluor ONE Lambda DNA provided with the QuantiFluor ONE dsdna System can be used as a DNA standard; however, we recommend preparing a standard using dsdna of a size similar to the dsdna you wish to quantitate. K562 Genomic DNA (human chronic myelogenous leukemia cell line; Cat.# E4931) is also available at a ready-to-use starting concentration for the QuantiFluor ONE dsdna add-and-read format. Instructions for using the Quantus Fluorometer are found in the Quantus Fluorometer Operating Manual #TM396 available at: www.promega.com/protocols Notes: 1. We recommend the use of a P2 pipettor for accurate pipetting of 1µl volumes in the following steps. See Section 7.D Tips for Pipetting Small Volumes if you are pipetting 1µl samples. Alternatively, minimize pipetting error by using >1μl of sample. 2. Other single-tube fluorometers can be used with the QuantiFluor ONE dsdna System if capable of measuring the following wavelengths (504nm Ex /531nm Em ) and calibrated using manufacturer s instructions. Step 1 Step 2 Step 3 Measure fluorescence. Dispense QuantiFluor ONE dsdna Dye into 0.5ml tubes, enough for each blank, standard and unknown sample. Add prepared blank, standard and unknown samples to 0.5ml tubes. Mix, and incubate for 5 minutes. 13563TA QuantiFluor ONE dsdna Dye Figure 1. Overview of the single-tube format quantitation using the QuantiFluor ONE dsdna System. Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 3 www.promega.com TM405 Revised 6/17

3. Protocol for Quantitating dsdna in a Single Tube Using the Quantus Fluorometer (continued) Note: If the Quantus Fluorometer was previously calibrated, you may not need to calibrate it again. Therefore, do not prepare blank and standard samples, and skip Steps 1, 2 and 6. 1. Prepare Blank Sample: Add 200µl of QuantiFluor ONE dsdna Dye to an empty 0.5ml PCR tube. This will be the blank sample used in Step 8. Protect tube from light. 2. Prepare 400ng Standard Sample: Add 1µl of the provided QuantiFluor ONE Lambda DNA standard (400μg/ml) to 200µl of QuantiFluor ONE dsdna Dye in an empty 0.5ml PCR tube. This will be the standard sample used in Step 8. Vortex well, and protect tube from light. Note: Alternatively, minimize pipetting error by adding 2µl of the 400ng/µl DNA standard to 400µl of QuantiFluor ONE dsdna Dye. 3. Prepare Unknown Sample: Add 1 20µl of unknown samples to 200µl of QuantiFluor ONE dsdna Dye in 0.5ml PCR tubes. For example, add 2µl of sample to 200µl of QuantiFluor ONE dsdna Dye. Vortex well, and protect tube from light. Note: Mix all tubes thoroughly by vortexing. To thoroughly mix using a pipette, set the pipettor to 180µl and pipet completely three times. Take care to not introduce bubbles during mixing, as air bubbles will adversely affect fluorescence values.! 4. Incubate reactions for 5 minutes at room temperature, protected from light. 5. Select the ONE DNA protocol on the Quantus Fluorometer. 6. If needed, calibrate the Quantus Fluorometer by reading the blank (prepared in Step 1) and standard (prepared in Step 2) samples in the Calibration screen, then select Save. 7. Enter the volume of the unknown sample and desired concentration units. Note: This volume is the amount of sample that is added for the quantitation. For example, if 2µl of sample was mixed with 200µl of QuantiFluor ONE dsdna Dye, then the volume entered on this screen should be 2µl. 8. Measure fluorescence of the unknown sample using the Quantus Fluorometer. The number displayed represents concentration of the original sample. 4 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 TM405 Revised 6/17 www.promega.com

4. Protocol for Quantitating dsdna in Multiwell Plates Materials to Be Supplied by the User multiwell detection instrument capable of measuring fluorescence (e.g., GloMax Discover System [Cat.# GM3000]) Nuclease-Free Water (Cat.# P1195) black, flat-bottom 96-well plates 1.5ml tubes optional: K562 Genomic DNA (Cat.# E4931) Instructions for use of the GloMax Discover System can be found in the GloMax Discover System Operating Manual #TM397, available at: www.promega.com/protocols Step 1 Step 2 Step 3 Dispense QuantiFluor ONE dsdna Dye into multiwell plate. Add blank, prepared standards and unknown samples to multiwell plate. Mix, and incubate for 5 minutes. Measure fluorescence. QuantiFluor ONE dsdna Dye 13564TA Figure 2. Overview of multiwell plate quantitation protocol using the QuantiFluor dsdna System. This multiwell plate protocol is designed to use 1 20µl of sample + 200µl of QuantiFluor ONE dsdna Dye. Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 5 www.promega.com TM405 Revised 6/17

4. Protocol for Quantitating dsdna in Multiwell Plates (continued) 1. Prepare a Standard Curve: a. Prepare seven 1.5ml tubes labeled: 400, 200, 50, 12.5, 3.1, 0.8 and 0.2. b. Prepare seven dsdna standards by preparing 1:1 and 1:4 serial dilutions of QuantiFluor ONE Lambda DNA (400ng/µl) according to Table 1. Taking care to not introduce air bubbles. Table 1. Preparing a dsdna Dilution Series for a Standard Curve from the 400ng/µl dsdna Standard. Standard Volume of dsdna Standard Volume of 1X TE Buffer Final dsdna Concentration (ng/µl) A 15µl of Undiluted Standard 0µl 400 B 10µl of Standard A 10µl 200 C 5µl of Standard B 15µl 50 D 5µl of Standard C 15µl 12.5 E 5µl of Standard D 15µl 3.1 F 5µl of Standard E 15µl 0.8 G 5µl of Standard F 15µl 0.2 Note: Use a P2 pipettor to more accurately pipet 1µl volumes in the following steps. 2. Pipet 200µl of the QuantiFluor ONE dsdna Dye to each well containing standard, blank and any wells of the plate that will be used for unknowns. 3. Pipet 1µl of the dsdna standards prepared in Table 1 above (labeled Standards A G) to rows A G of the multiwell plate (Figure 3). We recommend pipetting duplicates or triplicates of the standards. 4. For the blank, pipet 1µl of 1X TE Buffer into row H in duplicate or triplicate. 5. Add 1µl of unknown sample to the desired number of wells. 6 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 TM405 Revised 6/17 www.promega.com

dsdna Standards (ng/well) Unknown dsdna Samples A B C D E F G H 1 2 3 4 5 6 7 8 9 10 11 12 400 400 400 200 200 200 50 50 50 12.5 12.5 12.5 3.1 3.1 3.1 0.8 0.8 0.8 0.2 0.2 0.2 blank blank blank 13440MD Figure 3. Dispense standard dilutions and blank samples in triplicate into Columns 1, 2 and 3 of a multiwell plate. 6. Mix the plate thoroughly using a plate shaker or by pipetting the contents of each well. For example, set a 200µl multichannel pipettor to 180µl, and mix each column on the plate three times by pipetting and then ejecting the volume slowly. Use caution to avoid introducing air bubbles, which will interfere with fluorescence. 7. Incubate assays for 5 minutes at room temperature, protected from light. 8. Measure fluorescence (504nm Ex /531nm Em ). If using the GloMax Discover System, select the preloaded protocol: QuantiFluor ONE dsdna System. 9. Calculate the dsdna concentration as follows: Subtract the fluorescence of the blank sample (1X TE Buffer) from that of each standard and sample. Use the corrected data from the DNA standards to generate a standard curve of fluorescence versus DNA concentration. Determine the DNA concentration of the sample from the standard curve. Alternatively, copy and paste your raw fluorescence data into the Promega online tool: www.promega.com/resources/tools/quantifluor-dye-systems-data-analysis-workbook Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 7 www.promega.com TM405 Revised 6/17

5. Troubleshooting For questions not addressed here, please contact your local Promega Branch Office or Distributor. Contact information available at: www.promega.com. E-mail: techserv@promega.com Symptoms Low or no fluorescence detected No or low fluorescence detected in the unknown sample No or low fluorescence detected in the standard sample Fluorescence is too high Causes and Comments Check that the correct filter set was used for the QuantiFluor ONE dsdna Dye. Read fluorescence at 504nm(Ex)/531nm(Em). The QuantiFluor ONE dsdna Dye is light-sensitive. Exposure to light will reduce the sensitivity of the assay. Store the QuantiFluor ONE dsdna Dye in the provided amber bottle. Confirm that the unknown sample calculations were performed correctly. Check that the unknown sample was within the sensitivity range of the assay and standard curve. Increase the volume of unknown sample. For example, try 2 20µl of sample with 200µl of QuantiFluor ONE dsdna Dye. Evaluate the performance of the fluorometer with a dsdna sample of known concentration (e.g., QuantiFluor ONE Lambda DNA) using the appropriate excitation and emission wavelengths for the QuantiFluor ONE dsdna Dye. Check that the standard samples were diluted appropriately, if preparing a standard curve. Mix the dsdna standards with the QuantiFluor ONE dsdna Dye just prior to use. Extended exposure to light will decrease the amount of fluorescence detected. Check that the standard samples were diluted appropriately, if preparing a standard curve. If necessary, dilute the unknown sample prior to quantitation. Multiply the calculated result by the dilution factor to determine the concentration of the undiluted unknown sample. Adjust the gain setting on your fluorometer so that the highest point on the standard curve is approximately 90% of maximum signal. This is not necessary for the GloMax Detection Systems because these instruments will adjust automatically. The Quantus Fluorometer does not require gain adjustment. 8 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 TM405 Revised 6/17 www.promega.com

5. Troubleshooting (continued) Symptoms Causes and Comments dsdna concentration determined using the DNA concentrations determined using the QuantiFluor QuantiFluor ONE dsdna Dye differed from ONE dsdna Dye and optical density readings at 260nm concentration determined using an alternative will be different due to inherent quantitative differences method between methodologies. An optical density reading at A 260 reflects the amount of all nucleic acid (dsdna, ssdna, RNA and nucleotides) in the sample. The QuantiFluor ONE dsdna Dye intercalates into dsdna, and therefore, the amount of fluorescence is proportional to the amount of dsdna. If comparing concentrations determined using another dye-based quantitation method, carefully examine the blank-subtracted fluorescence of the two standard curves. The values should be proportional to the dilution factors used to create the standard curve. If the increase in fluorescence is not proportional to the increase in dsdna amount, the fluorescent dye(s) may be saturated. Recreate the standard curve, and decrease the concentration of the highest point of the standard curve. Determine the average fluorescence and standard deviation of the blank standards. Subtract the average fluorescence of the blank standards from the average fluorescence of the unknown and standard samples. The blank-subtracted fluorescence should be more than three standard deviations (as determined for the blank standards) above the average fluorescence for the blank standards. Nonlinear standard curve If the high or low end of curve is nonlinear, then adjust the standard sample dilutions such that the standard curve is linear. Adjust the gain setting on your fluorometer so that the highest point on the standard curve is approximately 90% of maximum signal. This is not necessary for the GloMax Detection Systems because these instruments will adjust automatically. The Quantus Fluorometer does not not require gain adjustment. Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 9 www.promega.com TM405 Revised 6/17

5. Troubleshooting (continued) Symptoms Nonlinear standard curve (continued) Causes and Comments Check that the lower-concentration standards are within the sensitivity range for the assay and assay format. Determine the average fluorescence and standard deviation of the blank standards. Subtract the average fluorescence of the blank standards from the average fluorescence of the unknown and standard samples. These blank-subtracted values should be greater than three standard deviations (as determined for the blank standards) above the average fluorescence for the blank standards. Pipetting was not accurate. If your standard curve was prepared using 1µl of each standard, refer to Section 9 Tips for Pipetting Small Volumes. Alternatively, prepare standard samples such that >1µl can be dispensed. Check that the unknown sample is within the sensitivity range of the assay and standard curve. The QuantiFluor ONE dsdna Dye was exposed to light. Exposure to light will reduce the sensitivity of the assay. Store the QuantiFluor ONE dsdna Dye and working solution protected from light. Analyze the data using either a linear regression or a power regression for accurate concentration determinations within the 10 400ng/µl portion of the standard curve. We recommend the use of a power regression for unknowns that are expected to be <10ng/µl. Alternatively, copy and paste your raw fluorescence data into the Promega online tool, which uses a power regression: www.promega.com/resources/tools/quantifluordye-systems-data-analysis-workbook or contact Technical Services for additional assistance. 10 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 TM405 Revised 6/17 www.promega.com

6. Interfering Compounds Several compounds that are commonly used in nucleic acid preparation or can be found in eluates from nucleic acid purification may affect the QuantiFluor ONE dsdna Dye. Table 2 lists compounds that have known effects on DNA quantitation using the QuantiFluor ONE dsdna Dye and the concentrations at which they affect quantitation results. Table 2. Compounds that Interfere with the QuantiFluor ONE dsdna Dye. Concentration of Chemical Compound Shown to Affect QuantiFluor ONE dsdna Dye* Lambda DNA (ng/well) Change in QuantiFluor ONE dsdna Dye Signal Guanidine Thiocyanate 4M 200 20% decrease Bovine Serum Albumin 0.08% 0.2 39% increase (BSA) Sodium Chloride 2.5M 0.2 3% increase Polyethylene Glycol 10% 0.0 4% increase (PEG 8000) Ethanol 0.6% 200 4% decrease ssdna 6.3ng 0.2 60% increase RNA 6.3ng 0.2 7% increase *Compounds were tested by adding 1µl at indicated concentrations in a 200µl final assay volume. 7. Handling and Disposal QuantiFluor ONE dsdna Dye contains an irritant that facilitates the entry of organic compounds into tissues. Wear gloves, safety glasses and a lab coat, and handle dyes with care. Because the QuantiFluor ONE dsdna Dye binds to nucleic acid, it should be treated as a potential mutagen. Dispose of the QuantiFluor ONE dsdna Dye according to local regulations. 8. Composition of Buffers and Solutions 1X TE Buffer (ph 7.5) 10mM Tris buffer (ph 7.5) 1mM EDTA Prepare the solution in nuclease-free water. Adjust the ph to 7.5. Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 11 www.promega.com TM405 Revised 6/17

9. Tips for Pipetting Small Volumes 1. Hand-held pipettes are high precision instruments and should be handled carefully. Pipettes should also be routinely checked for accuracy every 6 12 months, and recalibrated or repaired by qualified professionals. 2. Use newer model pipettes with more modern press fit tips for the most accurate and reproducible results. 3. Basic pipetting guidelines: When resetting a pipette to a new volume, turn the adjustment knob ½ turn higher than the target volume and then rotate back to the target volume. Pipet using a slow, smooth action. Hold the pipette vertically when drawing liquid in Only immerse the pipette tip slightly when aspirating liquid. When dispensing the liquid, hold the pipette vertically but keep the sidewall of the receiving vessel at a 45 degree angle. Pipette against the sidewall or into liquid that is already present. 4. Use the proper pipettor for the measured volume. When pipetting 1µl or 2µl, use a P2 pipettor for accuracy and reproducibility. Using aerosol or barrier tips with a P2 is not recommended. 5. All solutions, standards and unknowns should be at room temperature prior to pipetting. (See the following Nature Methods Application Note for more information: www.nature.com/app_notes/nmeth/2007/071109/full/nmeth1086.html) For a comprehensive guide on pipetting, we recommend the following resource: www.gilson.com/resources/gilson%20guide%20to%20pipetting%20third%20edition.pdf 10. Related Products Product Size Cat.# Quantus NGS Starter Package 1 each E5150 QuantiFluor ONE dsdna System 100 reactions E4871 500 reactions E4870 QuantiFluor RNA System 1ml E3310 QuantiFluor ssdna System 1ml E3190 GloMax Instruments Product Size Cat.# GloMax Discover System 1 each GM3000 GloMax Explorer Fully Loaded Model 1 each GM3500 GloMax Explorer with Luminescence and Fluorescence 1 each GM3510 12 Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 TM405 Revised 6/17 www.promega.com

Handheld Fluorometer Product Size Cat.# Quantus Fluorometer 1 each E6150 0.5ml PCR Tubes 50 pack E4941 Product Size Cat.# Nuclease-Free Water 50ml P1193 150ml P1195 TE Buffer, 1X, Molecular Biology Grade 100ml V6231 500ml V6232 K562 Genomic DNA 80µg E4931 11. Summary of Changes The following changes were made to the 6/17 revision of this document: 1. Revised the protocol. 2. Removed discontinued product listings. (a) Patent Pending. 2013, 2017 Promega Corporation. All Rights Reserved. GloMax and QuantiFluor are registered trademarks of Promega Corporation. Quantus is a trademark of Promega Corporation. Products may be covered by pending or issued patents or may have certain limitations. Please visit our Web site for more information. All prices and specifications are subject to change without prior notice. Product claims are subject to change. Please contact Promega Technical Services or access the Promega online catalog for the most up-to-date information on Promega products. Promega Corporation 2800 Woods Hollow Road Madison, WI 53711-5399 USA Toll Free in USA 800-356-9526 608-274-4330 Fax 608-277-2516 13 www.promega.com TM405 Revised 6/17