Facilities Management System That Reduces Environmental Burden of Buildings

Similar documents
The ECOMAX Controller Realizes an EMS for Use in Stores

Study on Energy Saving Control of Electrical System in Office Building

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

intelligent Building Energy Management System (ibems) Stefano Mangili Schneider Electric Spa 25/05/2016

Design and implementation of energy management system software in green building

Application of Environmental Load Analysis to Branch Office Monitoring

A Simulation-based Control Approach in a Mechanical Ventilation. System

WEB-BASED BUILDING AUTOMATION SYSTEM

South River Technologies Case Study: Labware

Trane Water-Source Variable Refrigerant Flow

Cross-system Integration of an Intelligent Factory

Findings of Field Survey for Thermal Comfort and Ventilation in US Office Buildings

Reducing running costs, whilst benefiting the environment and the future

Control Products & Systems OEM siemens.com/buildingtechnologies-oem

Thermal comfort study of a hawker center in Singapore

Bryant University s Energy Guidelines for Sustainability

Innotech is a registered Trademark of Mass Electronics Pty Ltd Copyright 2013 Mass Electronics Pty Ltd

Special edition paper Research on Utilizing Air Thermal Energy for Railway Facilities

Cisco Connected Asset Manager for IoT Intelligence

ENERGY CONSERVATION IN BUILDINGS AND COMMUNITY SYSTEMS. Technical Report. P. Michel & M. El Mankibi ENTPE DGCB LASH France

Set Free Modular FSXN. Engineering for tomorrow. And the tomorrow after that.

Field Commander. Overview. Operations. Custom Solution. Building Startup/Shutdown

A Method for On-Going Commissioning of VRV Package Systems Using a. Simulation Model

REDEFINING APPROPRIATE THERMAL COMFORT STANDARD FOR NATURALLY VENTILATED BUILDINGS IN TROPICS (SINGAPORE AND INDONESIA PERSPECTIVE)

FUJITSU LABORATORIES LTD. Sustainability Report 2015

Analysis of Distributed Energy Supplying Technologies From the Viewpoint of Waste Heat

HVAC INTEGRATED CONTROL FOR ENERGY SAVING AND COMFORT ENHANCEMENT vahid Vakiloroaya

Meet the New Standard. in Building Management Solutions for Commercial Buildings

Energy Saving Control System for Freezing- Refrigerating Warehouse

24/7 monitoring and supervision of your system

Evaluation methods for indoor environmental quality assessment according to EN15251

Energy-efficient Building Control. close to you

Summary Paper on Controls for HVAC

2B. Performance Advantages of Alerton BACnet. 1. Alerton Overview

Introduction and utilizing of natural energy in Net ZEB practice

1. How the research adds to the understanding of the area investigated

GATES-HILLMAN CENTERS

Various Applications of High-efficiency H-25 Gas Turbine

Nilan VPL Active heat recovery and cooling (air/air)

Case Study. Review of control strategy for a primary school built to PassivHaus standard

SENTRON Powermanager. SENTRON Powermanager. Identifying hidden potential for energy optimization and savings. Answers for industry.

RESEARCH ON THE ADVANCED USE OF MULTI-SPLIT TYPE AIR-CONDITIONING SYSTEM

ROOF TOP SPACE. SELF-CONTAINED REVERSIBLE AIR-AIR UNITS OF 23 TO 281 kw EVERY EFFICIENT SOLUTION FOR UNIVERSAL COMFORT NA C

Energy Efficiency. best in class

Energy Conservation for Office Buildings. Major points, measures, and successful cases of energy conservation for office buildings

Retro-Commissioning the Multi-Purpose Technical Building of Hitachi Building Systems Co., Ltd.

Building Commissioning for Energy Efficiency and Comfort, Vol.VI-8-4

Heat pumps. Oilon ChillHeat. Optimized cooling and heating performance

REAL-TIME CONTROL OF OCCUPANTS THERMAL COMFORT IN BUILDINGS. Galway, Ireland

Design of integrated control system for indoor environment*

Analysis of the Window Side Thermal Environment Formed by Air Barrier. Technique in Winter Conditions and Its Economy

SMART BUILDINGS. Always the best climate for. Zehnder ComfoAir Q ventilation units

Device Networks and the Internet

LABORATORY CONTROL SOLUTIONS FROM TSI

Numerical Investigation on Ventilation Strategy for Laboratories: A Novel Approach to Control Thermal Comfort Using Cooling Panels

Technologies for Raising Efficiency in Support Services

Business Creation in the Environment and Energy Fields

Cloud Service for Transformation of On-site Work through Smart Devices

Computrols Background

New Process Control Systems in the Energy Sector

Compact with impact. DVM S Eco

Heat Pump Air Curtains

Thermal Environment evaluation in Commercial kitchens: Procedure of data collection

DeltaV Continuous Historian

NEBB-ASHRAE elearning Course Descriptions for Technical Training E-Learning Courses

Trane VRF. variable refrigerant systems

Vetsmarttubes Cooling Tubes. Agricultural Product for Light and Air

Renewable Energy 2014/15

Heat pumps. WP5 Education and Economic Promotion

COMPUTER MODELING OF UNDERFLOOR AIR SUPPLY SYSTEM

Designing Air-Distribution Systems To Maximize Comfort

Thermal comfort and occupant adaptive behaviour in university offices with cooling and free running modes

SIMATIC PCS 7 Process Control System New Perspectives for Increased Productivity 2005 Highlights. simatic PCS7

COMPANY PROFILE. Energy Srl Piazza Manifattura, Rovereto TN Italy

UNDERFLOOR AIR DISTRIBUTION INTEGRATED WITH AN INDIRECT AND DIRECT EVAPORATIVE COOLING ASSISTED 100% OUTDOOR AIR SYSTEM

Online data sheet MAC800 CUSTOMIZED ANALYZER SYSTEMS

Save with Business Programs and Services

Industrial heat pumps and cooling machines Oilon ChillHeat. Optimized heating and cooling performance

Paul Ehrlich, PE Ira Goldschmidt, PE

Potential for Improved Outdoor Comfort by Design in U.S. Climates

Establishment of Global Recycle Network

Establishment of Global Recycle Network

CASE STUDIES ON HVAC SYSTEM PERFORMANCE USING A WHOLE BUILDING SIMULATION BASED REAL-TIME ENERGY EVALUATION APPROACH WITH BEMS

Prediction of Energy Efficiency and Thermal Environment of Residential Buildings Utilizing PEFC-CGS Combined Floor Heating System

Renewable Energy

Analysis of Night Ventilation Potential for Residential Buildings in Hot-Humid Climate of Malaysia

MEETING TODAY S GROWING NEED TO UNDERSTAND ENERGY CONSUMPTION

Spectrum PowerCC DM Distribution Management The control system for distribution network operators

Thermia Large capacity Heat pumps

ENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE

Heat Pump Hot Water Supply Systems

Thermal Comfort and Energy Consumption according to the Indoor Control Logic

Fujitsu s Approach for Eco-efficiency Factor

ORC TURBOGENERATOR TYPE CHP - Organic Rankine Cycle Turbogenerator fed by thermal oil, for the combined production of electric energy and heat -

AUTOMATION. Presents. Smart Building Solutions

PROBA 5. In control of ripening tropical fruit. World leaders in process control.

Introduction of Energy Data Analysis Center(EDAC)

Yokohama Smart City Project

Questionnaire-based survey on selection of energy-saving measures for offices

ARCHITECTURE AND FIELD TEST OF A RESTFUL WEB SERVICE FOR THE OPTIMISATION OF SPACE HEATING IN A COMMERCIAL OFFICE

Transcription:

Facilities Management System That Reduces Environmental Burden of Buildings V Masahiro Maeeda (Manuscript received February 1, 2005) In recent years, the problem of global warming has become serious, and it has become an important challenge for architects to reduce the environmental burden of buildings. In response, Fujitsu has developed facilities management systems called Futuric that make buildings safer and more comfortable by collecting information about equipment in buildings and then making it available for management and purposes. Lately, however, more importance has been attached to reducing environmental burden by providing energy-conservation functions for entire buildings. The Futuric facilities management systems have various energy conservation functions in their building energy and environment management systems (BEMSs) to support environmental burden reduction. This paper introduces the Futuric systems and describes how they help reduce a building s environmental burden using an example introduction in an office building. 1. Introduction Facilities management systems are generally called building automation systems (BASs) because they are systems for achieving safety, livability, energy conservation, and laborsaving in facilities by collectively managing and ling information about, for example, electricity supply, air-conditioning, lighting, hygiene, and disaster and crime prevention. Fujitsu introduced its first BAS system in 1975 and since then has introduced them to about 1100 facilities. The main function of facilities management systems was originally focused on the conservation of energy and laborsaving through the automation of equipment management. However, the revision of the Energy Conservation Law in April 2002 obliged building owners to periodically report their energy management to the Government and formulate mid-term to long-term plans for reducing their energy consumption and CO 2 emissions. The Futuric systems, therefore, have become important tools for achieving environment and energy conservation. Against this background, Fujitsu has developed three Futuric systems: Futuric/B, Futuric/BILCYBER, and Futuric/SX. note 1) These systems support standardization of communication protocol, materials, operating system (OS), and data and have a flexible configuration and many BEMS functions. 2. Outline of latest Futuric system: Futuric/SX The latest Futuric system, Futuric/SX, is divided into three fields: the local field, operation/ integration field, and client field. Moreover, it is composed of four main elements: human interface modules (HIMs), intelligent lers (s), remote s (RSs), and a building energy and environment management system (BEMS). Figure 1 shows the concept of the system, and note 1) Fujitsu total and supervise system for Facilities and UTilities of URban InfrastruCture 166 FUJITSU Sci. Tech. J., 41,2,p.166-172(July 2005)

Client field PC PC WWW server OA-LAN WAN (Internet) PC Operation & integration field HIM #1 HIM #2 BEMS Central equipment BACnet-LAN from other supplier from other supplier from other supplier LonTalk LonTalk Local field from other supplier from other supplier from other supplier HIM: Human interface module : Intelligent ler BEMS: Building Energy & Environment Management System Figure 1 System concept of Futuric/SX. Figure 2 shows a photograph of the central equipment. 1) The s collect dry-relay data from the RSs, convert it into BACnet protocol, note 2) and then transmit the converted data to the HIMs. The HIMs processes the received data and report the results to the manager by displaying them on the HIM monitors and using audio signals and other means. The manager uses the HIMs to send on/ off and setting instructions in BACnet protocol to the s and also receive /setting signals from the RSs. The BEMS cooperates with the HIMs and s to collect and store energy note 2) A Data Communication Protocol for Building Automation Control Network: BACnet is a registered trademark of the American Society of Heating, Refrigerating and Air- Conditioning Engineers (ASHRAE). data about equipment to support the management of equipment maintenance and management of energy and the environment. 3. Features of Futuric/SX Futuric/SX has two main features. Firstly, it supports globalization for easy construction of a multi-vender system. Secondly, it has various functions for conserving energy and protecting the environment. 3.1 Standardization support Futuric/SX supports standardization of the communication protocol, materials, operating system (OS), and data. 1) Standardization of communication protocol The BACnet protocol described in ISO standard 16484-5 is adopted as the communication FUJITSU Sci. Tech. J., 41,2,(July 2005) 167

Figure 2 Central equipment of Futuric/SX. protocol in the operation/integration field. Also, the de-facto LonWorks note 3) standard is adopted as the communication protocol in the local field. The adoption of these two protocols enables seamless connections of various equipment without the need for gateway equipment, making it easier to collect large amounts of data. 2) Open building information The BEMS collects data about equipment and makes the data available to personal computers (PCs) in the client field. In addition, it is used in conjunction with a Web browser and PCs to monitor equipment, change temperature settings, and change the operating schedule of air-conditioners. Furthermore, the BEMS is used to tally up accumulated energy data in order to publicize reductions in CO 2 and other emissions on the Web and allows the data to be downloaded to PCs. 3.2 Environment and energy consumption function support Because of the growing importance of environmental protection, the need to conserve energy during a facility s operation has become much stronger. As a result, there have been high expectations that the BEMS will be an effective energy conservation measure for office buildings to help prevent global warming. Therefore, Futuric/SX incorporates various energy saving functions, the main ones of which are summarized in Table 1. Compared to conventional systems, Futuric/ SX is physically much smaller and consumes much less power. Calculations made according to the Environmental Assessment Method used by Fujitsu note 4) show that compared to other systems, this system achieves a 46.7% or more than 17 kg reduction in CO 2 per year (Figure 3). Recently, a subsidy system to support the note 3) Local Operating NetWorks: LonWorks is a registered trademark of Echelon Corporation. note 4) This is a Fujitsu Laboratories method provided to customers when they introduce Futuric. It makes trial calculations of a facility s environmental impact in terms of CO 2 emissions before and after Futuric is introduced. 168 FUJITSU Sci. Tech. J., 41,2,(July 2005)

Table 1 Main energy conservation support function list of Futuric/SX. Class General Electric power Airconditioning BEMS Function Schedule Event Electric power demand monitoring Electric power demand Power factor improvement Target temperature setting Season mode switch Intermittent operation Air intake Data storage Energy data analysis Environmental performance data recording & management Summary Enables equipment to run automatically based on the operation pattern to which equipment is set beforehand. Also, automatically adjusts operation times of season-dependent equipment at season changes. Performs ON/OFF and setting of equipment set beforehand in case of status changes, alarms, and analog measurement abnormalities. Monitors cyclic electric power consumption. When the system forecasts an electric power consumption exceeding the contracted amount of electric power, it reports the situation to the operator. When an electric power demand alarm is generated, this function performs cut-off of the equipment that caused the power demand excess. After recovery from the alarm, this function turns on equipment as power becomes available. Performs ON/OFF of phase advance capacitor to bring power factor close to 100%. Automatically adjusts settings of air-conditioning facilities based on previous year s settings. Performs automatic switch of equipment that changes its operation mode at season changes. Performs intermittent operation in cycles and in time zones set beforehand to conserve energy for power equipment, etc. Compares outdoor air enthalpy with indoor air enthalpy and performs open/close of air dumper for energy conservation by effective use of heat and coldness sources (e.g., hot air and cold water). Accumulates energy data collected with Futuric over a long period for easy output to external media in a versatile format and easy analysis/processing by general-purpose software. Detects wasteful energy consumption by calculating/processing energy data collected by Futuric and graphically displaying it to support energy conservation judgments. Automatically sends consumption amounts of electricity, water, gas, and other commodities collected by Futuric to environmental performance data recording management system (SLIMOFFICE* 1 ) so the amounts of exhausted CO 2, Nox, Sox, etc., can be calculated to support environmental management. *1 System developed by Fujitsu FIP Ltd. This system quantitatively manages the amount of environmental burden generated as well as the amount of consumption every month due to production activities of all types of business (e.g., manufacturing, circulation industries, and municipalities) to monitor the converted CO 2 and money values. FUJITSU Sci. Tech. J., 41,2,(July 2005) 169

Exhausted CO2 (%) 100 80 60 40 20 Network data communication amount IT/network machine power Office space 0.1 38.8 61.1 46.7% 0.02 13.3 39.8 0 Before After * Exhausted CO 2 before introduction taken as 100% Figure 3 Exhausted CO 2 before and after Futuric/SX introduction. introduction of BEMSs has been established by the Ministry of Economy, Trade and Industry as a measure for environment and energy conservation. Also, when facilities management systems are replaced or upgraded, BEMS data will be analyzed to help protect the environment together with the customer. The next section looks at an example in which Futuric/SX was introduced to conserve energy in an office. 4. Environmental burden reduction after introducing Futuric/SX 2) In this section, we described how Futuric/SX reduced the environmental burden in the offices of a company in the gas industry in 2002. The system configuration of the office is shown in Figure 4. In the office, a conventional data-collection management system was developed so the staff could participate in energy conservation and the of indoor temperature over the Web by accumulating data and using the most suitable equipment based on that data. Table 2 shows the main functions that were introduced for the office. After Futuric/SX was introduced, the system began to regularly collect data and analyze it. When the system detected a potential loss of energy, it analyzed the potential causes. The necessary maintenance was done, and the office staff established a detailed energy conservation plan through energy conservation management. By introducing the most suitable operation functions, Futuric/SX made a remarkable reduction in the environmental burden of this office without decreasing the comfort of the staff. Moreover, a further reduction in environmental burden was achieved by encouraging the staff to become more aware of environmental problems and participate in energy conservation activities. The energy conservation effect graph for the introduction of Futuric/SX is shown in Figure 5. Over the course of one year, compared to ordinary offices, this office achieved a 9% (measured) higher energy conservation in the west building and at least a 30% (calculated) higher conservation in the east building. 5. Conclusion This paper introduced Fujitsu s Futuric facilities management system and described how it helps reduce a building s environmental burden using an example introduction in an office building. Since its release in 1975, Futuric has offered various energy conservation functions. However, in order to promote even better energy conservation in the future, it will be necessary to quickly support equipment upgrades and offer more effective energy conservation functions. To achieve this goal, more detailed data must be collected. Moreover, because energy conservation and human comfort sometimes conflict with each other, when introducing energy conservation functions, the people who live or work in the building need 170 FUJITSU Sci. Tech. J., 41,2,(July 2005)

HIM center management PC Dedicated line BEMS Display of trend graph and energy-saving results. Setting of calculation & factor parameters. Data storage Measurement data Calculated data Hub Hub Hub Data saving (electricity) RS, LON Amount of electric power Amount of gas OA equipment power outlets Figure 4 Futuric/SX system of office example. (air-conditioning) Automatic equipment Air conditioning status Fan operation status Temperature sensor Humidity sensor Flow meter HIM: Human interface module : Intelligent ler RS: LON: Local operating networks module Table 2 Energy conservation functions used for example office. Function Best operation mode Best CGS* 1 Night purge Energy conservation results indication Electronic questionnaire (air-conditioning comfort) Summary Selects whether to use natural ventilation, ceiling fans, floor blow air-conditioning or a combination thereof to select the best mode for energy conservation. The operation mode of CGS is determined by simulating the energy cost and amount of CO 2 emission. Exchanges air of offices using cool air of night to reduce air-conditioning consumption during the next day. Improves staff s awareness of energy conservation by measuring and totaling the amount of energy used on each floor and in each zone and then emails results to the staff. Conducts questionnaires about staff s comfort and calculates amount of clothes being worn and staff s metabolism based on data from BEMS. Then, sends results to PMV* 2 value calculation for air-conditioning. *1: CGS: The Cogeneration System generates electric power using, for example, diesel generators, and recycles exhausted heat from generators. *2: Abbreviation of Predicted Mean Vote (expected average temperature comfort report), which is an index showing temperature comfort based on six parameters (temperature, humidity, air flow, radiation, amount of clothes worn, and amount of physical activity). FUJITSU Sci. Tech. J., 41,2,(July 2005) 171

General office bldg. Sanitation Lighting Air conditioning auxiliaries 89 Energy consumption (Mcal/m 2 year) 140 Ventilation fans Air-conditioning fan Special burden 41 47 117 Adapted from Handbook of environmental design. 434 Mcal/m 2 year Electrical energy consumption for parking lighting, direction system, etc. West bldg. (Measurement results) 64 181 26 34 95 184 400 Mcal/m 2 year Energy conservation is about 9% East bldg. (Test calculation) 89 63 22 38 53 265 Mcal/m 2 year Energy conservation is over 30% Figure 5 Reduction of primary energy consumption. to participate in the process. It is also necessary to forecast how the new functions will affect their comfort. In a typical facility, the energy required to condition air and the air-conditioning equipment accounts for almost 30% of the overall energy consumption; therefore, a reduction of air-conditioning energy consumption can greatly reduce a facility s overall consumption. Moreover, although heat exhaustion through natural ventilation of air to the outside and the use of cogeneration systems (CGSs) are very effective, they are heavily influenced by the outside temperature and other weather conditions. Therefore, there will be big demands for energy conservation functions that optimally air conditioners and other equipment in cooperation with weather data, weather forecasts, and other information. Because Futuric is still in the verification stage, our main tasks now are to collect and analyze data after Futuric introductions, analyze the potential causes of potential energy losses, and feed back our results to develop concrete methods for better energy conservation. References 1) M. Maeeda et al.: Facilities Management System. (in Japanese), FUJITSU ACCESS REVIEW, 13, 1, p.57-63 (2004). 2) K. Oka et al.: Sakai Gas Building. (in Japanese), Heating Piping & Air Conditioning, 3, p.56-70 (2004). Masahiro Maeeda received the M.S. degree in Overall Sciences and Engineering: Thermal Energy System Engineering from the Interdisciplinary Graduate School of Engineering Sciences at Kyushu University, Fukuoka, Japan in 1992. He joined Fujitsu Ltd., Kawasaki, Japan in April the same year and devoted himself to the system engineering of facilities management systems until 1998. Since 1998, he has been planning and developing facilities management systems. He is a member of the Building Automation System (BAS) protocol enhancement promotion committee of the Institute of Electrical Installation Engineers of Japan (IEIEJ) and is also engaged in domestic dissemination activities for BACnet. 172 FUJITSU Sci. Tech. J., 41,2,(July 2005)