PRINCIPLES OF OPERATION

Similar documents
After reviewing this tutorial, the user should be able to Topics to be covered

REFERENCES FOR CURRENT NRC REGULATIONS: PARTS 20 AND 35.

2014 Meeting of Mid-Atlantic States Radiation Control Programs

in94070.txt at Page 1 of 5 2/24/00

Revised Regulations for Medical Use of Byproduct Material Review of U.S. NRC s revised 10 CFR Part 35

OFFICE OF ENVIRONMENTAL HEALTH AND RADIATION SAFETY (EHRS)

University of Maryland Baltimore. Radiation Safety Procedure

Brachytherapy Source Calibration

OFFICE OF ENVIRONMENTAL HEALTH AND RADIATION SAFETY (EHRS)

Brachytherapy Practice Problems EXTRA

NRC REGULATORY ISSUE SUMMARY LICENSING REQUIREMENTS FOR SENTINEL LYMPH NODE BIOPSY

STUDY OF THE ELUTION OF 99 Mo- 99m Tc GENERATORS PRODUCED AT IPEN-CNEN/SP

Microsphere Brachytherapy Sources and Devices

RADIOACTIVE MATERIALS REGULATORY GUIDE

Determination of 99 Mo contamination in 99m Tc elute obtained from 99 Mo / 99m Tc- generator

FY 2015 Fee Schedule. Table 1 Schedule of Source, Special Nuclear, and Byproduct Material Annual Fees

SUPPLEMENTAL ALPHABETICAL LISTING OF ISOTOPES ATOMLAB DOSE CALIBRATORS. FOR CALIBRATORS WITH 6.0 V and HIGHER SOFTWARE updated 3/8/06

Radiation Safety Manual

Microsphere Brachytherapy Sources and Devices

BALL STATE UNIVERSITY RADIATION PROTECTION PROCEDURES* USER S GUIDE

Swette Center for Environmental Biotechnology Radiation Safety Policy

Chapter 3 Obtaining an Authorization to Possess and Use Radioactive Material

Chapter 7 Transportation of Radioactive Material

RADIATION SAFETY AND PROTECTION

Date June 2, 2006 Page 1 of 5. Approved By

Estimation of the Radiation Effective Dose for Workers in 99m Tc Generator Production

MEDICAL RADIOACTIVE WASTE MANAGEMENT IN SAUDI ARABIA

Radioactive Substances Act 1993 The Environmental Permitting (England and Wales) (Amendment) Regulations 2011

Gamma Ray Spectroscopy of Lutetium Metal Element

USP Chapter 823 USP 32 (old) vs. USP 35 (new)

Fee Schedule FY2019. Table 1 Schedule of Source, Special Nuclear, and Byproduct Material Annual Fees

The use of personal protective equipment in nuclear medicine

THE INTERNATIONAL PHARMACOPOEIA

APPENDIX B INSTRUCTIONS AND SAMPLE APPLICATION FORMS FOR AUTHORIZATION

Radiation Safety Training Instructions

So Now You Are The RSO Radiation Safety Programs. Norman W. Henry III, MS,CIH SHBP (Safety and Health By Protection) comcast.

Standard Operating Procedure. Handling of Radioactive Material. PC-SOP-IM-005-v02

Western Michigan University

RSP-2 Page 1 of 12. Environmental Health and Safety Radiation Protection Committee

THE RICHARD STOCKTON COLLEGE OF NEW JERSEY. Natural Sciences and Mathematics Department. Radiation Safety Program

Atomlab. Dose Calibrators Wipe Test Counter IODEX. The Clinical Advantage. fast, accurate measurements. Bring science,

THE UNIVERSITY OF AKRON RADIATION SAFETY PROGRAM

IMPORTANT DRUG INFORMATION UPDATE

ARKANSAS DEPARTMENT OF HEALTH RADIATION CONTROL SECTION RADIOACTIVE MATERIALS PROGRAM LICENSING GUIDE INSTRUCTIONS FOR PREPARING AN APPLICATION

Regulatory aspects: Radiopharmacy (GMP)

Rad Monitor Set Points and the RETS. Jim Key Key Solutions, Inc.

PERFUSION TECHNOLOFISTS OF GREATER CHICAGO, INC. POLICY AND PROCEDURE MEDTRONIC HEMOTEC ACTIVATED CLOTTING TIME (ACT) OPERATING PROCEDURE

California Polytechnic State University San Luis Obispo. Radiation Safety Manual

The Impact of NRC Guidance on Concentration Averaging on Low Level Waste Sealed Source Disposal

Radioisotope Batteries. Jake Blanchard University of Wisconsin April 2010

Radiation Safety Procedure. Contamination Monitoring

MPI Pyrophosphate Kit Kit for the Preparation of Technetium Tc 99m Pyrophosphate DIAGNOSTIC-FOR INTRAVENOUS USE

CONTAMINATED SCRAP METAL-DIFICULTIES TO DETECT. Paulo Fernando Lavalle Heilbron Filho Nerbe J. Ruperti Junior. Abstract

HEALTH PHYSICS Emergency Procedures and Levels of Action

Radioisotopes production technology -EGYPT experience

CRC -15R RADIOISOTOPE DOSE CALIBRATOR OWNER S MANUAL

University of Richmond Radiation Safety Manual

Imaging Requirements (RTOG 1106/ACRIN 6697) Adam Opanowski, CNMT, PET, NCT, R.T.(N)(ARRT) Imaging Analyst ACR Core Laboratory

WM'00 Conference, February 27 - March 2, 2000, Tucson, AZ

CQIE PET PROCEDURES. American College of Radiology Clinical Research Center. Centers for Quantitative Imaging Excellence LEARNING MODULE

Measurement Uncertainty Guide. ISO Accreditation Program

WM 04 Conference, February 29- March 4, 2004, Tucson, AZ CONCRETE SLAB AND BIO-SHIELD SAMPLING, CHARACTERIZATION, AND ANALYSIS USING THE TRUPRO

Environmental Regulator's RWA Syllabus mapped to PHE's RPTS courses. RPTS coverage EA. No

Reduction of Backscattered Radiation in Enclosure X-ray Radiography

Understanding Coating Thickness Measurement Helmut Fischer

A SURVEY OF RADIOACTIVE WASTE DISPOSAL IN IRELAND

Radiation Safety Policy & Procedures

Ge / 68 Ga GENERATOR* HOW TO DO PET AS SIMPLY AS SPECT? EXCELLENCE DEDICATED TO NUCLEAR MEDICINE, HEALTHCARE & ENVIRONMENT

OHS Ionising Radiation Procedure

X-RAY THICKNESS GAGES OF THE RIT10 FAMILY FOR THICKNESS MEASUREMENT AT LINE PRODUCTION OF ROLLED METAL

Nanotechnology and Energy Harvesting from Radioisotopes

RADIATION SAFETY MANUAL

Complies with the monograph for Parenteral Preparations and with that for Radiopharmaceuticals.

RESPONSIBILITIES Each person who works with unsealed or dispersible radioactive materials is responsible for:

PROPOSED RULEMAKING ENVIRONMENTAL QUALITY BOARD

Technescan MAG3. NAME OF THE MEDICINE Technescan MAG3 Kit for the Preparation of Technetium ( 99m Tc) Mertiatide.

Calibration Procedures for Hand-Foot Contamination Monitors

2 / 1. SUMMARY public, should be well documented, and should be reviewed on a regular basis to determine whether it continues to meet the operational

The University of Texas Health Science Center at San Antonio Environmental Health & Safety Department Radiation Safety Division

Radiation Safety at the University of Vermont

D.L. Woodman, W.K. Andersen, and A.E. May

THALLOUS ( 201 Tl) CHLORIDE INJECTION: Revised Final text for addition to The International Pharmacopoeia (January September 2009)

GOOD LABORATORY PRACTICE Agilent Cary 8454 UV-Visible Spectroscopy System

Preliminary tests of a commercial extrapolation chamber for utilization as a beta radiation standard system

EE C245 ME C218 Introduction to MEMS Design Fall 2007

P780 Annual Refresher Radiation Safety Training. P780 Radiation Safety

UAB Radioactive Materials Spill Response Procedure For the Radiation Worker

MATERIAL SAFETY DATA SHEET SECTION 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION SECTION 2. COMPOSITION, INFORMATION ON INGREDIENTS

QUALITY CONTROL AND ASSURANCE OF Tc-99m GENERATORS AND KITS APPLIED IN SAEC LABORATORIES

MINIMIZATION AND SEGREGATION OF RADIOACTIVE WASTES IAEA, VIENNA, 1992 IAEA-TECDOC-652 ISSN

Draft Guidelines for Radiopharmacy

Designing a PET Facility - Shielding and Radiation Protection

RADIATION PROCEDURES MANUAL Procedure Cover Sheet

Method No.: 8.06/2.0/M Effective Date: January 4, 2012 Location: ###

RADIATION SAFETY MANUAL THE UNIVERSITY OF SOUTHERN MISSISSIPPI HATTIESBURG, MISSISSIPPI. January, Prepared by:

STUDY OF THE PERFORMANCE OF EFFICIENCY TRACING TECHNIQUE ON A TRICARB 2100TR LIQUID SCINTILLATION ANALYZER

THE UNIVERSITY OF CHICAGO APPLICATION FOR NON-HUMAN USE OF RADIOACTIVE MATERIAL

Nuclear Substances in Canada: A Safety Performance Report for 2013

Regulation DD-26.0: Radioactive Works

Concrete Slab and Bio-shield Sampling, Characterization, and Analysis Using The

Transcription:

A dose calibrators is an integral part of any nuclear medicine department. This tutorial focuses on the main principles of operation and all of the issues related to quality control testing of this equipment; in addition, it describes a dose calibrator and discusses the principles and the parameters within which it works as well as patient related and NRC issues. Included is a detailed description of the required quality control tests and the testing frequency required to keep this equipment operational. PRINCIPLES OF OPERATION The typical radioisotope calibrator contains an ionization chamber, a high voltage power supply, an electronic amplifier, and a display unit on which one can select the radioisotope to be calibrated. The ionization chamber is cylindrical in shape (see photos below) and is used to measure the total amount of ionization produced by the sample to be calibrated. The ionization chamber contains Argon gas under high pressure, often 20-30 atm) and the hermetically sealed chamber contains two electrodes having an electric potential between them. When the vial or syringe containing the radionuclide is placed into the chamber, the Argon gas is ionized, the ion pairs migrate toward the anode and cathode and an electrical current flows between them. This current is proportional to the activity of the measured radioisotope. The magnitude of this current is usually very small (on the microampere level), even if large amounts of activity are present. A device called an electrometer, designed for quantifying very small electric currents, is used and its output is displayed in either mci or MBq. Dose calibrator function is based on a number of parameters. Most important are the activity, the energy level of the photons, and whether particulate emitters (e.g., beta particles) are being calibrated. The chamber s response is different for pure gamma emitters like Tc-99m than for a beta/gamma emitter like I-131. This means that the dose calibrator requires a different internal setting for each individual radioisotope. It is particularly difficult to calibrate a pure beta emitter such as Y-90. The readings are very geometry dependent, aside from other issues such as self-absorption in the sample being measured and X-ray production when the beta particles interact with the lead shielding

surrounding the ionization chamber. The use of custom-designed lightweight plastic sample holders and deep-well detectors has virtually eliminated poor results caused by variations in sample positioning in the well. PATIENT RELATED ISSUES Every dose administered to a patient must be assayed in a properly functioning radioisotope dose calibrator. This device must be capable of reliably calibrating doses as small as 10 µci as well as on the multi-ci range. Central Radiopharmacies routinely handle activities in the range of 5-15 Ci of Tc-99m. According to current NRC Regulations, administered doses must be within ±20% of the prescribed dose. It is the obligation of the person calibrating the dose, typically the Nuclear Medicine Technologist, to assay the dose and to insure that it meets the specification set down in the 20% rule (all administered doses must be within 20% of the prescribed dose). Some Agreement States require that administered doses must be within ±10% of the prescribed dose. The prescribed dose may be modified only by a physician and a note must be made on the requisition and initialed by the physician indicating the change in prescribed dose. Dose Calibrator Operation and Quality Control Testing

One is required to evaluate calibrator performance on-site at specified intervals. The current NRC Regulations displayed below were taken from the Code of Federal Regulations, Title 10, Part 35.60: 35.60 Possession, use, and calibration of instruments used to measure the activity of unsealed byproduct material. (a) For direct measurements performed in accordance with 35.63, a licensee shall possess and use instrumentation to measure the activity of unsealed byproduct material before it is administered to each patient or human research subject. (b) A licensee shall calibrate the instrumentation required in paragraph (a) of this section in accordance with nationally recognized standards or the manufacturer s instructions. (c) A licensee shall retain a record of each instrument calibration required by this section in accordance with 35.2060. The nationally recognized standards mentioned in (b) above are published by the NIST (National Institute for Standard and Technology) and are downloadable (for a fee) from their website. The condition of reliability exists when both accuracy and precision are maintained. To insure that the dose calibrator is reliable, there are certain mandatory quality control tests that must be performed on a routine basis. Required Dose Calibrator Tests and Frequency of Performance The required dose calibrator tests and the frequency of their performance are listed in the following chart. TEST REQUIRED Accuracy Constancy Linearity Geometry FREQUENCY at installation, then annually thereafter at installation, then daily thereafter at installation, then quarterly thereafter at Installation; after repair or moving instrument It is essential to perform these test procedures correctly since patient safety is highly dependent upon the reliability of this instrument. All too often, procedural errors are made in performing QC testing of dose calibrators, even by experienced operators. It is critical to perform steps in the proper order to insure correct readings. The following paragraphs describe the recommended procedure for performance of mandatory dose calibrator quality control testing and are in compliance with guidelines set forth in the most recent NIST publication regulating dose calibrator quality control test procedures.

Accuracy Test This test is designed to show that the calibrator is giving correct readings throughout the entire energy scale one is likely to encounter. Low, medium, and high energy standards (usually Co 57, Ba 133 or Cs 137, and Co 60, respectively), are measured in the dose calibrator using appropriate settings. The value on the label indicating the activity at a specific calibration time and date is mathematically decay-corrected to the testing date. The standard is then assayed in the dose calibrator and standard and measured values are compared. All values are recorded in the appropriate logbook. Measured values should be within ± 10% of the standard value. The following table displays the data collected during an annual Accuracy Test. The dose calibrator has passed the test. Standard Energy (kev) expected value (mci) measured value (mci) Co-57 122 2.48 2.48 Cs-137 662 3.38 3.29 Co-60 1,332 1.55 1.52

Constancy Test This test, performed at installation and daily, measures instrument precision and is designed to show that reproducible readings are obtained day after day on all the various isotope settings likely to be used. A long-lived source, usually 30 yr Cs-137, is placed in the dose calibrator. Activity is then measured on the Cs-137 setting (this actually represents a "mini" accuracy test) and on all other settings used on a daily basis. Values are recorded in the appropriate logbook and are compared with recent values to determine if the instrument is performing consistently on a day-to-day basis. Measured values must be within ± 10% of the standard value. It should be noted that, since we are reading the activity of a Cs 137 source on settings for Tc 99m, Tl 201, I 123, Xe 133, and other isotopes, incorrect readings will be obtained. Our expectation is to obtain the same incorrect reading day after day. The following table displays the data collected during a daily constancy test over a one-week time period. The dose calibrator has passed the test. ISOTOPE READING (mci) SETTING MONDAY TUESDAY WEDNESDAY THURSDAY FRIDAY Cs 137 123 124 122 126 124 Ga 67 223 224 222 224 226 Tl 201 163 164 162 166 164 Tc 99m 243 242 244 246 244 I 131 313 314 312 316 314 I 123 193 192 194 196 194 In 111 283 284 282 286 284 Xe 133 433 434 432 436 434

Linearity Test This test is designed to prove that the dose calibrator readout is linear for sources varying from the µci range through the mci range. A high activity Tc 99m source (50-300 mci) is measured at T 0 and at predetermined time intervals until activity reaches approximately 30 µci. This can take as long as 96 hours, depending upon initial activity. Using decay factors for Tc 99m, one can take the activity at T 0 and decay-correct it to predict what the activity should be at the predetermined times. Expected and actual measurements are recorded in the appropriate logbook (and may be analyzed graphically), and then are compared to determine if the instrument is linear throughout the usable activity range of the dose calibrator. The following table displays the data collected during a quarterly Linearity Test. The dose calibrator has passed the test. Elapsed time Expected reading Measured reading (hr) (mci) (mci) 0 300 300 1 267 272 2 238 241 3 212 209 6 150 148 12 75 72.4 24 18.75 19.1 48 1.17 1.19 72 0.073 0.074 78 0.036 0.037

Geometry Test This test is designed to show that correct readings can be obtained regardless of the sample size or geometry. It therefore is necessary to perform this test on every different vial used (e.g., 10 ml, 30 ml)as well as every different syringe used (e.g., 1 ml, 3 ml, 5 ml, 10 ml). For example, to test a 10 ml syringe for linearity, one first places 1.0 ml of Tc 99m in a 10 ml syringe (activity 25 mci). The activity is then measured in the dose calibrator and the value obtained is recorded. The activity is then diluted with water to 2.0 ml, 3.0 ml, 4.0 ml, 5.0 m, etc, up to 10 ml. At each of these points a reading is taken and the value recorded. Data are then evaluated to determine the effect of sample geometry on the dose calibrator reading. If the instrument is geometry-dependent, ideally one should notify the manufacturer that the calibrator has failed acceptance testing and a new calibrator should be requested. If the decision is made to keep the instrument, it may be necessary to routinely correct readings obtained when using calibrator. The following table displays the data collected during a Geometry Test. The dose calibrator has passed the test. Sample Activity Volume (mci) 0.5 25.5 1.0 25.3 2.0 25.0 3.0 24.8 4.0 24.7 5.0 24.5 6.0 24.4

Specifications for All Dose Calibrator QC Tests NRC and State Regulations require that, for all dose calibrator tests, deviation between standard and expected values must be within ±10%. If the deviation is greater than 10%, then one's obligation is to record the value, note that it is a test failure, repair or recalibrate the instrument, retest to insure that the equipment is now functioning properly, and record new values. In addition to the above steps, every dose must be mathematically corrected until the instrument is repaired. There is no longer a reporting requirement. QC Test For Mo 99 Breakthrough Using A Dose Calibrator Mo 99 is assayed FIRST directly in the special lead pig supplied by the manufacturer of the dose calibrator using the Mo 99 setting. Tc 99m is THEN assayed directly in the plastic sleeve using the Tc 99m setting. Activity (µci) of Mo 99 is divided by activity (mci) of Tc-99m to obtain a ratio. If this ratio is <0.15 µci Mo 99 per mci of Tc 99m at time of administration, the generator eluate has passed the Mo 99 Breakthrough Test. As a rule of thumb, if the ratio is <0.038 at time of elution, the material will be suitable for injection for at least 12 hours. If test is performed in reverse order, failure is extremely likely due to residual charge on ionization chamber that takes a few minutes to dissipate.