Sub-construction for Wall-mounted Longlight

Similar documents
Sub-construction for longlight

Sub-construction for ridgelight

Sub-construction for Atrium Ridgelight

VELUX Modular Skylights

DICTATOR Lift Shaft System

MOUNTING SYSTEMS APPLICATIONS OVERVIEW

Northlights using VELUX Modular Skylights

Radiant Solar Tripod Planning and Installation Guide V1.2 With Australia AS/NZS1170.2

mounting systems applications overview

RUUKKI FORMA DESIGN INSTRUCTION

VELUX Modular Skylights

INSTALLATION GUIDE DUOFUSE DECKING

Product Information Bulletin

RUUKKI FAÇADE SYSTEMS

SECURE. UNIVERSAL. MOUNTING. Tilt Kit Installation Manual

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Prescriptive Design for Pole Barns Using the Larimer County Prescriptive Handout

COMP ONENT CATA LO GUE FOR INDUSTRIAL BUILDINGS

Stone and Masonry Veneer

Original Scandinavian rainwater system

Alisply Circular Headquarters - Spain Alsina USA - Chicago Alsina USA - Miami

PREFA Aluminiumprodukte GmbH Page 1 of 21

Note. Floor beams can also be made from wooden beams put through the holes in the longitudinal beam and boards nailed to it.

technical drawings Cutted roof tile Levelling batten Plasma roof tile Plasma eave tile (without ribs on the lower side) C Metalic batten Linkage tile

Rosette Modular Scaffolding System

CONSTRUCTION IMPORTANT TERMS AND FACTS CHAPTER 15

Renovation of Buildings using Steel Technologies (ROBUST)

Building Design Data

Façade claddings. Sandwich panel SPA, SPB W, SP2D W

WALL SYSTEMS ( Ref: The Building Illustrated, Ching, Francis DK )

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

HOISKO CLT SN 001. CLT external corner. CLT internal corner. CLT joining details. CLT element wall. Screw 8,0*220 k300 21*145. Seal CLT element wall

FREESTAND ROOF GUARDRAIL. Lockinex. ea i, ea u i

High-Spanning Glazing System Technical Guide.

Installation guide Thermory decking

Technical and Dimensional Data. Saf-T Vent SC

BARRIER BARRIER. quick installation. high quality collective side protection. ideal for escape routes. pleasing, unobtrusively design

1 Exam Prep Architectural Sheet Metal Manual Tabs and Highlights

High-Spanning Glazing System Technical Guide.

WHAT IS CANTILEVER RACK?

rockspan installation guide horizontally laid panel

Installation Guidelines INOFIN FR

Precast Concrete Trench Drain Systems INSTALLATION INSTRUCTIONS

Thesis Proposal Structural Redesign / Cost, Schedule and Coordination Analysis / Architectural Impact

SECTION PLATE CONNECTED WOOD TRUSSES

ORDINANCE NO BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF BOULDER, COLORADO: CHAPTER 98 - Baled Straw Structures SECTION PURPOSE

MOUNTING SYSTEMS FOR TRAPEZOIDAL SHEET AND CORRUGATED SHEET ROOFS

ThermaSteel Corporation ASSEMBLY MANUAL

Contents DESIGNER S STRUCTURAL PRODUCTS GUIDE. Tegral Purlins & Rails

Multiwall Polycarbonate

TABLE OF CONTENTS. 1.0 INTRODUCTION 1.1 Greenstone Structural Engineered Panels 1.2 Drawing and Element Numbers

STRUCTURAL REPORT. Magerack Series 101 PV Mounting System. 130 mph Wind, Exposure B & C. California DESIGNER OF RECORD

INTERLOCKING PANELS by ARCHTECH

SHEET METAL ROOF TEST REPORT

Radiant PV-RoofTopRac System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT

Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170

DIVISION 07 - THERMAL & MOISTURE PROTECTION

Fundamentals of Insulated Panel Installation. MBCEA 2016 Clearwater, FL

La Escandella La Escandella La Escandella

The Structural Redesign of Boyds Bear Country and its Related Systems. Boyds Bear Country, Pigeon Forge, Tennessee

THE DESIGN AND INSTALLATION OF A FIVE-STORY NEW TIMBER BUILDING IN JAPAN

Viking Enviroclad Waterproofing Membrane. EC01 Enviroclad Drip Edge Specify from the above three options

tracks for building maintenance units (BMU)

KEEP YOUR FAMILY SAFER FROM EARTHQUAKES AND TYPHOONS BY MAKING SURE YOUR HOUSE FOLLOWS THESE 6 BASIC PRINCIPLES

ROOF MOUNT KIT OWNERS MANUAL

INSTALLATION GUIDE.

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

Issue Date: April 2003 Release: I. Product Specifications

Sandwich panel SPA Product description

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

ROOF MOUNT KIT OWNERS MANUAL

ANCILLARY STEEL STRUCTURES FOR INDUSTRIAL AND CIVILIAN BUILDINGS. a r c h i t e c t u r e m a d e o f s t e e l STEEL INOX

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

TECHNICAL INFORMATION

Topduo Roofing screw. Corrosion protection. Advantages blue+ coating. Advantages Topduo Roofing screw

ifix INSTALLATION MANUAL PV flat roof installation system Version

Power IT Compact Secondary Substations, CSS. Technical catalogue for sheet steel substations

ESCONDIDO FIRE DEPT TRAINING MANUAL Section Truck Module Page 1 of 10 Building Construction Roof Types Revised

The Finnish Quality Since 1960

BISOL EasyMount Structures

SECTION ** NOTE TO SPECIFIER ** Overhead Door Corp.; Residential Sectional Overhead Door products.

Corium Brick Rainscreen System Specifications

ValkPitched - Clamp. Installation manual. Van der Valk Solar Systems. Solar Mounting Systems. Version 17 EN

(For standard pan width and minimum pitch refer to charts.) 6 Pan. Variable pan width Pan. Variable pan width Pan

MANUAL. landscape orientation. portrait orientation. metal roof mounting system for solar panels METAL ROOF MOUNTING SYSTEM. Rev

Light-Metal Roof Edge, Raised

30 X 40 POLE BARN 12 HIGH SIDE WALLS 2-12 WIDE X 10 HIGH SECTIONAL GARAGE DOORS OPTIONAL WINDOWS DETAILS INCLUDED

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

GENERAL FRAME INFORMATION

HelioFix Solar mounting Systems

FSR - Roof Guardrail with Rubber Counterweights. Fold down option available. Lockinex. ea i, ea u i R2_11/17

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

Masonry Veneer - Chapter 6. Masonry Veneer Anchored Veneer

Fascia Systems. oofing 7.1

ADJUSTABLE PIPING SUPPORT PRODUCT BROCHURE

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

ALLMET CONTINENTAL INSTALLATION GUIDE

Commercial Flashing Details

PREFA Aluminiumprodukte GmbH Page 1 of 25

Transcription:

modular skylights Sub-construction for Wall-mounted Longlight Subconstruction for Wall-mounted Longlight at 5-40 pitch modular skylights in a wall-mounted longlight solution, can be installed on a sub-construction made of steel, wood or concrete finished with a steel profile at the top of the bottom section and a steel flat bar mounted on the wall. The sub-construction raises the modules above the roof surface, protecting the construction against water and drifting snow, and provides the supporting base for the modular skylights. The sub-construction is not included in the delivery. The sub-construction as shown in the drawing only represents general principles and must be designed and dimensioned to fit the specific building project, local architectural style and practice, and the directions of other building suppliers.

2 Axonometric A: Opening width B: Opening length C: Sub-construction width D: Sub-construction length O: Height of gable P: Height of wall steel profile R: Placement of groove P O min 200mm 210 ± 5mm D ± 5 B 210 ± 5mm A C ± 5 210 ± 5mm

3 Building site measurements Elevation A: Opening width B: Opening length C: Sub-construction width D: Sub-construction length O: Height of gable P: Height of wall steel profile (To be verified) R: Placement of groove (To be verified) X: Distance between steel profiles (To be verified) O X R P min 200mm C ± 5mm min 200mm 210 ± 5 B D ± 5mm 210 ± 5 210 ± 5 A

4 Connecting to the wall The surface of the wall must suited for fixing screws, and either cutting a groove in or applying mastic sealant to and must be prepared for such accordingly. When cutting a groove for the top head flashing, the groove must subsequently be sealed again. If the wall is not suited for cutting a groove, the top head flashing is left out, and the main head flashing is sealed to the wall. The choice of sealant to use in the groove or on the flashing must be according to national requirements, local practice, and the directions of other building suppliers. The sealant is not part of the delivery. Connecting to the roof The surface on which roofing felt is laid must be prepared according to applicable standards for roofing materials and best building practice. The roofing felt must be applied to the outside of the sub-construction before mounting the skylight modules. Sub-construction dimensioning requirements The roof construction is subject to deflection after installation of the skylight modules. These deflections include subsequent roof covering, various building installations and external loads such as snow and wind etc. The sub-construction must be designed to withstand all these loads and the deflections must be limited to maximum 1/400 x the full length of the sub-construction. After completing the sub-construction, it must be secured against water penetrating the roof construction and insulation. 1/400 x L For load capacity and weight of the skylight modules, please contact your local modular skylight supplier.

5 Sub-construction variants Cross section top Options of sub-constructions for wall-mounted longlight solutions. Please note that the top groove in the wall can be left out. The head flashing is then sealed to the wall, using a suitable mastic sealant or equivalent. P Securing modular skylights to the wall Steel flat bar Wall-mounted modular skylights must be mounted on a steel flat bar on the wall. The steel flat bar must be wide and thick. There must be at least free space underneath the steel, both vertically and horizontally to allow room for the clamps. The number and size of fixings for securing the steel profile to the building must be dimensioned by others to fit each project. Requirements to the steel flat bar: ½ ½ The blocking-up of the steel must be in the full length of the steel flat bar The steel can be secured using screws or bolts along the middle of the profile Connection of steel profiles must not collide with clamps

6 Sub-construction variants Cross section bottom Options of sub-constructions for wall-mounted longlight solutions. Please note that the width stated indicates the distance from the finished exterior of the roofing material to the interior of the wood/steel profile. Wood with flat steel Wood with wooden batten Steel with steel profile Concrete with steel profile Concrete with flat steel Longitudinal section In the gable construction for wall-mounted longlight at 5-40 pitch, the height of the sub-construction must be at least at the front of the skylight modules.

7 Securing modular skylights to the sub-construction Using steel profile The sub-construction can be finished at the top with steel profile or steel flat bar, which provides a level and stable surface for the skylight modules and forms a base for fitting installation brackets with clamps. The number and size of fixings for securing the steel profile to the sub-construction must be dimensioned by others to fit each project. The following standard steel profiles are suited for installation of modular skylights in longlight solutions: EU steel beams: INP 220 IPE 200 HE100A HE100B British steel beams: UB 178 x 102 x 19 UB 203 x 102 x 23 UB 254 x 102 x 22 UB 254 x 102 x 25 UB 305 x 102 x 25 UB 305 x 102 x 28 Wood or steel sub-construction with steel profile UB 305 x 102 x 33 In case a stronger construction is needed, the steel profile can be replaced with a stronger profile. In this case, a different size installation bolt must be ordered separately from Company Ltd. The following profiles can be used: EU steel beams: INP 240, 260, 280 IPE 220, 240 HE120A HE120B British steel beams: UB 305 x 127 x 37 UB 305 x 127 x 42 UB 356 x 127 x 33 235 mm Concrete sub-construction with steel profile Straightness of steel profile Requirements to the straightness of the steel profile is maximum 2 mm over any given 2 meters. Max. 2 mm / 2 m Max. 2 mm / 2 m

8 Using steel flat bar When mounting the modular skylights on steel flat bar, the steel must be wide and thick. In addition there must be at least free space underneath the steel both vertically and horizontally to allow room for the clamps. The number and size of fixings for securing the steel profile to the sub-construction must be dimensioned by others to fit each project. Requirements to a steel flat bar: ½ ½ The blocking-up of the steel must be in the full length of the steel flat bar The steel can be secured using screws or bolts along the middle of the profile Connection of steel profiles must not collide with clamps 235 mm Steel or wood sub-construction with steel flat bar Concrete sub-construction with steel flat bar Straightness of a steel flat bar Requirements to the straightness of the steel profile is maximum 2 mm over any given 2 meters. Max. 2 mm / 2 m Max. 2 mm / 2 m

9 Using wooden battens The sub-construction for the longlight can also be finished off using a wooden batten on which the bottom shoes of the modular skylight can be secured directly, without using the supplied installation clamps. The skylight modules are mounted on the batten using screws through the bottom shoes. These screws are not included in the delivery, and the correct dimensions must be ensured by the customer. There are 4 holes in each shoe, 2 x ø5 and 2 x ø8.5. Wood sub-construction with wooden batten V-455267 2011 Group., THE RED logo and io-homecontrol are registered trademarks used under license by THE velux Group. Company Ltd Woodside Way Glenrothes Fife KY7 4ND Tel: 01592 778 916 Email: vms@velux.co.uk