Seismic Retrofitting of Building with Soft Storey and Floating Column

Similar documents
Earthquake Behavior of RCC Building for Various Shear Wall Configurations

SEISMIC RETROFITTING OF DORMITORY BUILDINGS WITH SOFT STOREY AND FLOATING COLUMNS

COMPARATIVE STUDY ON 3D RC FRAME STRUCTURE WITH AND WITHOUT FLOATING COLUMNS FOR STIFFNESS IRREGULARITIES SUBJECTED TO SEISMIC LOADING

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

Seismic Analysis of Buildings with Shear Wall having Horizontal Irregularity

ANALYSIS AND EVALUATION OF STRUCTURAL SYSTEMS WITH BRACING AND SHEAR WALL

Analysis of G+12 Structures with different material of Shear wall using SAP2000

STUDY OF SEISMIC PERFORMANCE OF RC BUILDING WITH FLAT PLATE INFLUENCED BY CONCRETE WALL

A Study on Seismic Analysis of High Rise Irregular Floor Plan Building with Different Position of Shear Walls

Result Analysis of Multistorey Building by Using Response Spectrum Method for Floating Column

PARAMETRIC STUDY ON VERTICAL IRREGULAR HIGH RISE REINFORCED CONCRETE FRAMED BUILDING

Seismic Response of Vertically Irregular RC Frame with Stiffness Irregularity at Fourth Floor

Effect of Mass and Stiffness of Vertically Irregular RC Structure

EARTHQUAKE ANALYSIS OF A G+12 STOREY BUILDING WITH AND WITHOUT INFILL FOR BHUJ AND KOYNA EARTHQUAKE FUNCTIONS

Seismic Analysis of a High-rise RC Framed Structure with Irregularities

SEISMIC RESPONSE OF VERTICALLY IRREGULAR RC FRAME WITH MASS IRREGULARITY

EARTHQUAKE RESPONSE OF TALL BUILDINGS HAVING DIFFERENT SPACING OF COLUMN BAY

THE INTERNATIONAL JOURNAL OF SCIENCE & TECHNOLEDGE

SEISMIC PERFORMANCE OF HIGH-RISE BUILDING

SEISMIC RESPONSE OF MULTI-STOREY STRUCTURES WITH FLOATING COLUMNS

COMPARATIVE STUDY ON DESIGN RESULTS OF A MULTI-STORIED BUILDING USING STAAD PRO AND ETABS FOR REGULAR AND IRREGULAR PLAN CONFIGURATION

SEISMIC BEHAVIOR OF RC BUILDING FRAME WITH STEEL BRACING SYSTEM USING VARIOUS ARRANGEMENTS

Pushover Analysis Of RCC Building With Soft Storey At Different Levels.

STUDY ON CONCENTRIC STEEL BRACING AT SOFT STOREY DURING EARTHQUAKE

Seismic Analysis of RC Framed Building for Different Position of Shear wall

A Comparative Study of Seismic Response of Flat Slab Structure and Conventional RC Framed Structure

Ajay H A 1, Vijay Kumar Y M 2, Suresh Chandra 3 1 P.G. Student, 2 Assistant Professor, 3 Professor. IJRASET: All Rights are Reserved

Comparative Analysis of Moment Resisting Frames of Steel and Composite Materials

Comparative Study of Seismic Analysis between Conventional RC Frame and Flat Slab with Drop Muniraju K.S 1 Subramanya K.G. 2

Performance of Multi-story RCC structure with Floating Column

Comparative Study of Equivalent Static Analysis and Response spectrum analysis on Flat Slab Using Etabs

STUDY ON EFFECT OF OPEN GROUND STOREY ON SEISMIC PERFORMANCE OF HIGH RISE BUILDING

Torsional and Seismic Behavior of Shear Wall Dominant Flat Plate Buildings

EFFECT OF PLACEMENT AND OPENINGS IN SHEAR WALL ON THE DISPLACEMENT AT VARIOUS LEVELS IN A BUILDING SUBJECTED TO EARTHQUAKE LOADS

PERFORMANCE BASED SEISMIC ANALYSIS OF RC BUILDING USING SOFT STOREY CONSIDERATION

Seismic Analysis of a Multi-Storeyed Building with Irregular Plan Configuration Using ETABS N. Mohan Reddy 1 Dr. E. Arunakanthi 2

Analysis and Design of High-Rise RC Structure in Different Seismic Zones

Seismic Performance of Multistorey Building with Soft Storey at Different Level with RC Shear Wall

Linear and Non Linear (Pushover) Analysis of An Irregular Shape Multistorey Building with Different Shear Wall Position

A Study on Positioning of Different Shapes of Shear Walls in L Shaped Building Subjected to Seismic Forces

TO STUDY THE PERFORMANCE OF HIGH-RISE BUILDING UNDER LATERAL LOAD WITH BARE FRAME AND SHEAR WALL WITH OPENINGS

Dynamic analysis of RC frame braced tube structure

SEISMIC DEMAND STUDY OF SOFT STOREY BUILDING AND IT S STRENGTHENING FOR SEISMIC RESISTANCE

International Journal of Scientific & Engineering Research, Volume 5, Issue 5, May ISSN

Pushover Analysis of RC Frame for effective column design

DYNAMIC ANALYSIS OF MULTI-STOREY BUILDING

EFFECT OF DIFFERENT SHEAR WALL CONFIGURATIONS ON SEISMIC RESPONSE OF A MOMENT-RESISTING FRAME

COMPARATIVE STUDY OF LINEAR AND NON-LINEAR SEISMIC RESPONSE OF RC STRUCTURE SITUATED IN DIFFERENT SEISMIC ZONES OF INDIA

BEHAVIOURAL STUDY OF STIFFNESS IN SOFT STOREY BUILDINGS WITH DIFFERENT INFILLS

Comparative Study of Multi-storeyed RC Building With Open Ground Storey Having Different Type Infill Walls

EFFECT OF CHANGE IN THICKNESSES AND HEIGHT IN SHEAR WALL ON DEFLECTION OF MULTISTORIED BUILDINGS

International Journal of Scientific & Engineering Research, Volume 5, Issue 5, May ISSN

EARTHQUAKE BEHAVIOR OF BUILDING USING STAAD PRO

IJSRD - International Journal for Scientific Research & Development Vol. 5, Issue 06, 2017 ISSN (online):

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 09, 2014 ISSN (online):

Significance of Shear Wall in Multi-Storey Structure With Seismic Analysis

SEISMIC PERFORMANCE OF HIGH RISE FLAT SLAB BUILDING WITH VARIOUS LATERAL LOAD RESISTING SYSTEMS

Department of Civil Engineering, SKP Engg. College, Tiruvanamalai, TN, India

SEISMIC RESPONSE OF A MID RISE RCC BUILDING WITH SOFT STOREY AT GROUND FLOOR

EFFECTS OF P-DELTA ON HIGH RISE BUILDINGS LOCATED IN SEISMIC ZONES

International Journal of Scientific & Engineering Research, Volume 7, Issue 5, May ISSN

SIGNIFICANCE OF SHEAR WALL IN FLAT SLAB MULTI STORIED BUILDING - A REVIEW. Vavanoor, India

RESPONSE SPECTRUM ANALYSIS OF MULTI- STOREY BUILDING WITH FLOATING COLUMNS

Analysis of Seismic Pounding between Adjacent Buildings

Study of Strength of RC Shear Wall at Different Location on Multi-Storied Residential Building

Analysis of Shear Wall in High Rise Unsymmetrical Building Using Etabs

Dynamic Behavior of High-Rise RC Building with a Vertical Irregularity

[Gajbe* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Project Title. Comparative Study of Shear wall in multistoried

Effect of Openings in Shear Wall

ANALYSIS OF G+15 RCC AND COMPOSITE STRUCTURE HAVING A SOFT STOREY AT GROUND LEVEL BY RESPONSE SPECTRUM AND EQUIVALENT STATIC METHODS USING ETABS 2013

EFFECT OF SHAPE IRREGULARITY ON FLAT SLAB INDUSTRIAL BUILDING UNDER LATERAL LOADING

Analysis of Soft Storey Building in Different Seismic Zones by Staad.Pro V8i Software

SEISMIC BEHAVIOUR OF RC BUILDING RESTING ON PLAIN AND SLOPING GROUND WITH BRACINGS AND SHEAR WALL

SEISMIC ANALYSIS OF HIGH RISE BUILDINGS WITH PLAN IRREGULARITY

Analysis of Unsymmetrical Building Resting on Sloping Ground by Dividing In 2D Frame

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 2, No 2, 2011

seismic analysis of multistoried rcc building due to mass irregularity

A Study On Seismic Analysis of Multistorey Building With Floating Column Using Staad.ProV8i

THE STUDY ON BEHAVIOUR OF OUTRIGGERS FOR TALL BUILDINGS SUBJECTED TO LATERAL LOAD

COMPARATIVE STUDY ON REGULAR & IRREGULAR STRUCTURES USING EQUIVALENT STATIC AND RESPONSE SPECTRUM METHODS

Modelling and Analysis of Irregular Geometrical Configured RCC Multi- Storey Building Using Shear Wall

Seismic Analysis and Design of Regular and Irregular Framed Commercial Buildings

Seismic Performance of RC & Composite Frames with Plan Irregular Configurations

P-Delta Effects on Tall RC Buildings with and Without Shear Wall

Seismic Performance Of R C Flat-Slab Building Structural Systems

Optimum Position of Multi Outrigger Belt Truss in Tall Buildings Subjected to Earthquake and Wind Load

Effects Of Vertical Geometric And Mass Irregularities In Structure

International Journal of Intellectual Advancements and Research in Engineering Computations

Comparative study of effect of different positions of shear wall on transfer girder for wind, conventional and stage analysis.

Management, Amravati. 2 Assistant Professor, Department of Civil Engineering, G. H. Raisoni College of Engineering and

1. INTRODUCTION 1.1 FLAT SLAB. 275 P a g e

SSRG International Journal of Civil Engineering ( SSRG IJCE ) Volume 4 Issue 6 June 2017

OPTIMUM LOCATION OF SHEAR WALL IN A MULTI-STOREY BUILDING SUBJECTED TO SEISMIC BEHAVIOR USING GENETIC ALGORITHM

SEISMIC VULNERABILITY OF EXISTING RC BUILDINGS IN INDIA

Study of Shear Walls in Different Locations of Multistoried Building with Uniform Thickness in Seismic Zone III

Effect of Diaphragm Openings in Multi-storeyed RC framed buildings using Pushover analysis

STUDIES ON LOCATION OF SHEAR WALL IN BUILDINGS FOR STRUCTURAL STABILITY

"Comparative study on conventional beam slab and flat slab under various seismic zones and soil conditions

Seismic Behavior of High Rise Building for Soft Soil in All Seismic Zones Shaik Fayaz 1 Mrs. B.Ajitha 2

Transcription:

Seismic Retrofitting of Building with Soft Storey and Floating Column Ganesh Kumbhar 1, Anirudhha Banhatti 2 1Department of Civil Engineering, G. H. Raisoni College of Engineering and Management, Wagholi, Pune. 2 Professor, Department of Civil Engineering, G. H. Raisoni College of Engineering and Management, Wagholi, Pune. ---------------------------------------------------------------------***--------------------------------------------------------------------- Abstract - Open ground storey along with the floating columns has been a peculiar feature in the latest multi-storey buildings in India. These features are hugely in admissible in the buildings which are built in earthquake prone areas. In this report, after understanding the behavior of buildings in earthquakes, why, when, where and how seismic retrofitting is done, has been studied. In addition, various local and global deficiencies in a building, along with their retrofit strategies, have also been studied. Further, a study is performed on an example building with open ground storey and floating columns to highlight the importance of their presence in the seismic analysis using program in ETABs. The analysis is done with Equivalent Static Analysis and Response Spectrum Analysis, as per IS:1893-2002. Various features of lateral stiffness strengthening system, namely lateral bracings, shear walls, increasing the column size in the soft ground storey and their combinations, and are proposed to reduce the stiffness irregularity and discontinuity in the load path incorporated by the soft ground storey and the floating columns respectively. Also, it is inspected that the shear walls are most impressive when used as one long structural wall instead of two short II METHODOLOGY walls having separated by the interrelated beams, and Modeling of frame structureproperly placed at the periphery of the buildings to avoid the torsion. It is also noticed that the Chevron braces are most productive when placed under the floating columns to make the force transfer less horizontal. Key Words: Open Ground Storey, Floating Column, Shear Walls, Braces. particularly with respect to seismic resistance. This is because of the up-gradation of the seismic code (IS:1893 Part 1-2002). Also the properly designed buildings which were constructed in the past, are lacking the earthquake resistance and the requirements of design codes, such as IS:4326-1993 and IS:13920-1993.The extent of seismic vulnerability can be verified only after a genuine evaluation of the structure is attempted. Depending on this evaluation, retrofitting of the vulnerable buildings can be started. The Seismic retrofitting can be done in different ways and to various extents. The purpose should be to certify that the building takes all the damage, but does not collapse when severe earthquake occurs. Seismic retrofitting of a building usually affects the functionality and use during the evaluation and further strengthening. The procedure of believing the users on the importance and necessity for retrofit is also very difficult. Thus, before a project is begun, the aim and procedure of the retrofitting have to be kept in mind. Modeling of structure is done in standard software ETAB which is based on finite element method. the space frame of multi-storey building is prepared considering special moment resisting frame. Column base are assigned as fixed support, column and beam are model as line element, slab and shear wall are area section but are assigned as membrane. 1. INTRODUCTION Casualties caused due to the recent earthquakes have unfolded the vulnerability of the Indian buildings. Most of the engineered constructions, such as multi-storied apartments are lacking the very basic features which are required for the resisting earthquakes. This may be because of the lack of awareness of earth quake resistant design and necessary requirements of the Indian codes. Nowadays, especially after the desolating Nepal earthquake 25 April 2015, there has been a mutual effort throughout India to provide more awareness, especially in practice and education, with respect to earthquake resistant design of structures. Model-1: A multistory frame building is taken into consideration. Building having a RCC members like slab, beams, and columns. Building having soft storey at ground floor, also floating columns at 1 st floor level. Model 2: Building model similar as 1 st model with increasing size of column of the soft storey. Model 3: Building model similar as 1 st model with steel bracings (cross bracings) at perimeter of the soft storey. Model 4: Building model similar as 1 st model with rcc shear wall at corners of the soft storey. Most of the existing buildings have revealed to deficit observance with the current practice codes, 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 1917

Basic load cases used for analysis- Table -1: Load Cases SR.NO Load cases Load 1 Dead load Gravity 2 Live load Gravity 3 Super imposed DL Gravity 4 EQX IS 1893:2002 5 EQY IS 1893:2002 Fig1- model 1 Fig2- model 2 Load consideration- Live load: 3 KN/m 2 Live load on stair: 4 KN/m 2 Super imposed load: 2KN/m 2 Brick wall load (230mm thk.): 13 KN/m Load combination used as per IS1893 (Part 1):2002 clause6.3.1.2, the following load cases have to be consider for analysis a) 1.5 (DL + IL) b) 1.2 (DL ± IL ± EL) Fig3 model 3 Fig4- model 4 Details of multistory frame building are as follows- Storey of building: G+ 5 storey Use of building: commercial Frame type: Special moment resisting frame structure Floor to floor height : 3 m Seismic zone: Zone III Soil type: Medium soil (Type II) Shear wall: 230 mm thick Steel bracings; steel cross bracings (ISMB200). c) 1.5 (DL ± EL) d) 0.9 DL ± 1.5 EL Section properties - Preliminary section properties are taken into consideration while modeling the structure, section properties of beam, column and shear walls are as follows. Beam in X-direction : 230 x 525 mm Beam in Y-direction : 230 x 525 mm Column : 230 x 525 mm Retrofitted column : 230 x 750 mm RCC slab RCC shear wall : 150 mm thick : 230 mm thick Earthquake zone : III Size of steel bracing : ISMB200 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 1918

Displacement in mm International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-0056 III SEISMIC ANALYSIS OF BUILDING- 1. Story Shear The recent increase in the speed of computers has made it practical to run many time history analyses in a short period of time. In addition, it is now possible to run design checks as a function of time, which produces superior results, since each member is designed by the response spectrum method. IV RESULTS AND DISSCUSION Fig7-Story Shear (KN) Fig5-model of structure1 Fig8-Story Shear (KN) G+5 building without retrofit, base shear obtained from earthquake analysis is less than that obtained from retrofit structures. Fig6-model of structure2 2. Story Displacement Story Displacement - Structure1 20 15 10 5 0 Story Model1 Model2 Model3 Model4 Fig9-story displacement (in mm) 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 1919

Drift in mm International Research Journal of Engineering and Technology (IRJET) e-issn: 2395-0056 As per IS 1893(part1): 2002 (cl 7.11.1) storey shall not exceed 0.004 times of story height. In this study maximum story height is 3m and as per IS recommendation allowable story drift is 7.2mm. 4.Time Period Fig10-Story Displacement (in mm), The displacement of without shear wall building is more, and it is not feasible for high rise structure. Displacement can be control by using various retrofitting methods. 3. Story Drift Fig13-Time Period Fig11-Story Drift Fig14-Time Period 4 3 2 1 0 Story Drift - Structure2 5 4 3 2 1 G.F. Soft story Story Time period of building is more it means the structural damage of the building is minimum. But Deflection is more, so we can control by using various position of shear wall in structure. Model1 Model2 Model3 Model4 Fig12-Story Drift 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 1920

V. CONCLUSION Story displacement of 1 st structure model 2 is 2 mm at soft story which is lesser than the other models. For same structure the ground floor displacement is less for shear wall retrofit structure which is 3.3mm at top of the retrofit. Story displacement of the 2 nd structure for model 2 is also 2mm at bottom of the soft story and for shear wall retrofit it is 3.7mm at the top of retrofit. So that shear wall retrofit is the best method of retrofit the soft story which also reduce the displacement of the whole structure. REFERENCES 1) A.P. Mundada and S.G. Sawdatkar (2014), Comparative Seismic Analysis of Multistorey Building with and without Floating Column. 2) Dr. SaraswatiSetia and Vineet Sharma (2012), Seismic Response of R.C.C Building with Soft Storey. 3) Gerardo Verderame and Flavia De Luca (2014), Preliminary analysis of a soft storey mechanism after the 2009 L'Aquila earthquake. 4) N. Lakshmanan (june 2006), seismic evaluation and retrofitting of buildings and structures. 5) L. Teresa Guevara-Perez(2013), Soft Story and Weak Story in EarthquakeResistant Design: A Multidisciplinary Approach. 6) Mr. P.V. Prasad and T.RajaSekhar, Study of BehaviourOf Seismic Analysis Of Multi Storied Building With And Without Floating Column. 7) Umesh P. Patil and Shivanand S Hallur2 (4 July 2015), Seismic Analysis of G+5 Framed Structures with and Without Floating Columns Using ETABS-2013 Software. 8) IS:456(2000), Indian Standard code of Practice for Plain and Reinforced concrete, bureau of Indian standard, New Delhi. 9) IS:875(1987) Indian standard code of practice for structural safety of buildings: loading standard (other than Earthquake),bureau of Indian standards, New Delhi 10)IS:1893(2000,Part 1), Indian standard criteria for earthquake Resistance Design of Structure, bureau of Indian standards, New Delhi. 2016, IRJET Impact Factor value: 4.45 ISO 9001:2008 Certified Journal Page 1921