Building Regulations

Similar documents
PINK BATTS POLYESTER INSULATION. Product. Scope. Building Regulations. Appraisal No. 999 [2018] Appraisal No. 999 (2018) BRANZ Appraisals

PREMIER INSULATION. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 509 [2014]

PINK BATTS INSULATION. Product. Scope. Building Regulations. Appraisal No. 238 [2012]

EARTHWOOL GLASSWOOL INSULATION. Product. Scope. Building Regulations. Appraisal No. 648 [2016]

SNUG UNDERFLOOR INSULATION. Product. Scope. Building Regulations. Appraisal No [2018] Appraisal No (2018) Amended 28 June 2018

AUTEX GREENSTUF UNDERFLOOR INSULATION. Product. Scope. Building Regulations. Appraisal No. 734 [2016]

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland

WATERGATE-PLUS 295 FIRE RETARDANT WALL UNDERLAY. Product. Scope. Appraisal No. 695 [2017]

WATERTIGHT ROOF UNDERLAY. Product. Scope. Building Regulations. Appraisal No. 938 [2017] Appraisal No. 938 (2017) BRANZ Appraisals

PAULOID SYNTHETIC ROOFING UNDERLAY. Product. Scope. Building Regulations. Appraisal No. 984 [2017] Appraisal No. 984 (2017) BRANZ Appraisals

Appraisal No. 719 (2011) BRANZ Appraisals Marshall Innovations Limited BRANZ

SYNTHETIC SELF SUPPORT ROOFING UNDERLAY

MULTI-FIT PENETRATION SEALS. Product. Scope. Appraisal No. 942 [2017] Appraisal No. 942 (2017) BRANZ Appraisals

CAVIBAT ROOF BATTENS. Product. Scope. Building Regulations. Appraisal No. 992 [2017] Please Note: Roof underlay not shown under flashing for clarity.

DYNAFLASH FLASHINGS. Product. Scope. Building Regulations. Appraisal No. 913 [2016] Appraisal No. 913 (2016) Amended 06 October 2016.

National Construction Code Series (NCC) Building Code of Australia (BCA)

SIKA BOOM AIR SEAL. Product. Scope. Building Regulations. Appraisal No. 452 [2013]

1222 Moonshine Rd, RD1, Porirua 5381 Private Bag Porirua 5240, New Zealand Tel: branz.co.nz. Important Notice

SOLITEX EXTASANA WALL PROTECTION MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 822 [2013] Appraisal No. 822 (2013) Amended 06 May 2014

EZYCORNER CAVITY FLASHING. Product. Scope. Building Regulations. Appraisal No. 920 [2016] Appraisal No. 920 (2016) BRANZ Appraisals

TESCON EXTORA SEALING TAPE. Product. Scope. Appraisal No. 838 [2013] Appraisal No. 838 (2013) Amended 30 June 2017.

TRADE-COURSE DPC AND FLASHING. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 849 [2014] Appraisal No.

THERMAKRAFT ALUBAND WINDOW FLASHING TAPE. Product. Scope. Building Regulations. Appraisal No. 878 [2014]

QUICKFLASH READY- MADE FLASHINGS. Product. Scope. Building Regulations. Appraisal No. 688 [2018]

KINGSPAN KOOLDUCT SYSTEM. Product. Scope. Building Regulations. Appraisal No. 771 [2017]

HRV VENTILATION SYSTEM. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 982 [2017] Appraisal No.

ROOF VENTILATION PRODUCTS. Product. Scope. Appraisal No. 979 [2017] Appraisal No. 979 (2017) BRANZ Appraisals

ROOF VENTILATION PRODUCTS. Product. Scope. Appraisal No. 979 [2017] Appraisal No. 979 (2017) Amended 06 December 2018.

MAYER STAINLESS STEEL PRESS-FIT PIPING SYSTEM. Product. Scope. Building Regulations. Appraisal No [2018] Appraisal No.

FRAMEFLASH / WATERTIGHT FLASHING TAPE. Product. Scope. Appraisal No. 631 [2017]

STEALTH ROOFLIGHTS. Product. Scope. Appraisal No. 987 [2018] Appraisal No. 987 (2018) BRANZ Appraisals

MLC MASONRY AND BRICK PLASTER SYSTEM. Product. Scope. Appraisal No. 839 [2013] Appraisal No. 839 (2013) BRANZ Appraisals

SUPERIOR DOORS. Product. Scope. Building Regulations. Appraisal No. 787 [2012] Appraisal No. 787 (2012) Amended 13 September 2016.

BOSTIK MS SAFE FIX ADHESIVE. Product. Scope. Appraisal No. 662 [2016] Appraisal No. 662 (2016) This Appraisal replaces BRANZ Appraisal No. 662 (2009).

METRA INTER- TENANCY WALL SYSTEM. Product. Scope. Appraisal No. 985 [2018] Appraisal No. 985 (2018) BRANZ Appraisals

MAGICSEAL RETROFIT SECONDARY GLAZING AND INSECT SCREENS. Product. Scope. Building Regulations. Technical Specification. Appraisal No.

HILTI CFS-SL / CP 653 / SPEED SLEEVE / FIRESTOP SLEEVE FIRE RATED COLLARS. Product. Scope. Building Regulations. Appraisal No.

TRAY-DEC FLOORING SYSTEM. Product. Scope. Building Regulations. Appraisal No. 841 [2014] Appraisal No. 841 (2014) BRANZ Appraisals

SIKA BLACKSEAL ELASTIC DAMP PROOF MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 770 [2012]

SUPERCOURSE 500 DAMP-PROOF COURSE AND CONCEALED FLASHING. Product. Scope. Building Regulations. Appraisal No. 329 [2016]

SIKALASTIC-152 EXTERIOR WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 811 [2013] Appraisal No. 811 (2013) Amended 28 August 2017

PROTECTO TAPE FLASHING TAPE. Product. Scope. Building Regulations. Appraisal No. 450 [2017]

LIQUID NAILS HIGH STRENGTH CONSTRUCTION ADHESIVE. Product. Scope. Appraisal No. 325 [2016]

SYMONITE CLADDING SYSTEM. Product. Scope. Appraisal No. 528 [2017]

SOLITEX EXTASANA ADHERO SELF-ADHESIVE UNDERLAY. Product. Scope. Appraisal No. 989 [2017] Appraisal No. 989 (2017) BRANZ Appraisals

PRIMA CERAMIC TILE UNDERLAY. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 636 [2008]

ROCKCOTE RESENE MONOTEK SYSTEMS

ALLIED CONCRETE READY FLOOR. Product. Scope. Building Regulations. Appraisal No. 810 [2017]

BLACKSEAL SB DPM MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 585 [2016]

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 957 [2017] Appraisal No. 957 (2017) BRANZ Appraisals

MULTITUBO PE-RT INVERSE PIPE SYSTEM FOR UNDERFLOOR HEATING. Product. Scope. Building Regulations. Technical Specification.

DS411 Exterior. Product. BRANZ APPRAISAL No. 788 (2012) Scope. Wet-seal New Zealand Ltd P O Box Takapuna Auckland Tel:

ARDEX UNDERTILE SHEET MEMBRANE (WPM 750 AND WPM 1000) Product. Scope. Building Regulations. Appraisal No. 727 [2017]

CS CAVITY SLIDERS. Product. Scope. Building Regulations. Appraisal No. 900 [2015] Appraisal No. 900 (2015) BRANZ Appraisals

SIKAPROOF A WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 852 [2014] Appraisal No. 852 (2014) Amended 24 April 2018

RAUPIANO PLUS ACOUSTIC PLUMBING AND DRAINAGE SYSTEM. Product. Scope. Building Regulations. Appraisal No. 809 [2013]

MULTICOM WALL PANEL SYSTEM. Product. Scope. Building Regulations. Appraisal No. 869 [2014] Appraisal No. 869 (2014) Amended 06 March 2015

TRIBOARD INTER-TENANCY WALL SYSTEM. Product. Scope. Appraisal No. 593 [2016]

SIKA CAR PARK DECK SYSTEM. Product. Scope. Appraisal No. 781 [2019] Appraisal No. 781 (2019) This Appraisal replaces BRANZ Appraisal No.

PROTECTOWALL DPM MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 517 [2013]

ECOPLY BARRIER RIGID AIR BARRIER. Product. Scope. Building Regulations. Appraisal No. 827 [2014] Appraisal No. 827 (2014) Amended 21 August 2017

HYDRATHANE INTERIOR WATERPROOFING MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 959 [2017] Appraisal No. 959 (2017) BRANZ Appraisals

National Construction Code Series (NCC 2012) Building Code of Australia (BCA)

USG BORAL WET AREA SYSTEMS. Product. Scope. Building Regulations. Appraisal No. 955 (2017) BRANZ Appraisals

STRATOCELL WHISPER FR SOUND ABSORBING FOAM. Product. Scope. Building Regulations. Appraisal No. 949 [2017] Appraisal No. 949 (2017) BRANZ Appraisals

VIKING GM TORCH ON MEMBRANES. Product. Scope. Appraisal No. 948 [2017] Appraisal No. 948 (2017) BRANZ Appraisals

Typical waterproofing using Shelterseal 3000X

VIKING GM MERCURY FC DPM MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 864 [2014] Appraisal No. 864 (2014) Amended 11 May 2017

ECOPLY BARRIER FOR STEEL. Product. Scope. Appraisal No [2018] Appraisal No (2018) BRANZ Appraisals

PERMAPHALT MASTIC ASPHALT ROOF WATERPROOFING SYSTEM. Product. Scope. Appraisal No [2018] Appraisal No (2018) BRANZ Appraisals

National Construction Code Series (NCC 2016) Building Code Of Australia (BCA)

DAVCO K10 PLUS AND K10 RAPID WET AREA MEMBRANES. Product. Scope. Building Regulations. Appraisal No. 609 [2017]

TRIBOARD CONSTRUCTION SYSTEM. Product. Scope. Appraisal No. 481 [2013]

VIKING PEEL & STICK MEMBRANE. Product. Scope. Building Regulations. Appraisal No. 826 [2014] Appraisal No. 826 (2012) BRANZ Appraisals

SIMPSON STRONG-TIE BOTTOM PLATE ANCHOR SOLUTIONS. Product. Scope. Building Regulations. Appraisal No. 983 [2018] Appraisal No.

Product. BRANZ APPRAISAL No. 789 (2012) Scope. Hard as Rocks Ltd PO Box 1703 Taupo 1351

ECOTUFF TPO ROOF AND DECK MEMBRANE. Product. Scope. Appraisal No. 792 [2012] Appraisal No. 792 (2012) Amended 05 October 2016.

GIB FIRE RATED SYSTEMS. Product. Scope. Building Regulations. Appraisal No. 289 [2018] Logo. Appraisal No. 289 (2018) BRANZ Appraisals

TRIBOARD CONSTRUCTION SYSTEM. Product. Scope. Appraisal No. 481 [2013]

THE THERMAKRAFT ONE WRAP SYSTEM. Product. Scope. Appraisal No. 962 [2017] Appraisal No. 962 (2017) BRANZ Appraisals

GIB FIRE RATED SYSTEMS. Product. Scope. Building Regulations. Fire Rated Systems Specification and Installation Manual GIB. Appraisal No.

Product. BRANZ APPRAISAL No. 436 (2011) Scope. Ardex New Zealand Limited P O Box Woolston Christchurch

Roof. Installation Instructions PINK BATTS CEILING INSULATION. Safety: pinkbatts.co.nz INSTALLATION INSTRUCTIONS

SIKAFLEX MS (BUILDING SEALANT) Product. Scope. Appraisal No. 311 [2013]

SPAPANEL WALL LINING SYSTEM. Product. Scope. Building Regulations. Appraisal No. 906 [2016] Appraisal No. 906 (2016) Amended 11 December 2017

Limitations and Conditions

DRYPROOF UNDER TILE EXTERNAL WATERPROOFING MEMBRANE. Product. Scope. Appraisal No. 887 [2015] Appraisal No. 887 (2015) Amended 17 September 2015

GIB EZYBRACE SYSTEMS 2011

EARTHWOOL INSULATION STANDARD SPECIFICATION

PRODUCT CERTIFICATE THIS IS TO CERTIFY THERMAKRAFT STEELWRAP 290 WALL UNDERLAY

MAPELASTIC, MAPELASTIC SMART AND MAPELASTIC TURBO EXTERNAL WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 485 [2018]

FIRESTONE RUBBERCOVER EPDM MEMBRANE. Product. Scope. Appraisal No. 893 [2015] Appraisal No. 893 (2015) Amended 24 November 2017.

DAVCO K10 PLUS AND K10 RAPID EXTERNAL WATERPROOFING MEMBRANES. Product. Scope. Appraisal No. 608 [2017]

HOMERIT PREMIUM SERIES PVC-U WINDOWS AND DOORS. Product. Scope. Appraisal No. 543 [2007] Appraisal No. 543 (2007) Amended 21 October 2013

Bituminous Building Paper

Product. BRANZ APPRAISAL No. 474 (2010) Scope. Flexco (NZ) Ltd P O Box South Auckland Mail Centre Manukau City

Product. BRANZ APPRAISAL No. 732 (2012) Scope. Nuralite Waterproofing Ltd 53a Victoria Street Onehunga Auckland

METRAPANEL SYSTEM. Product. Scope. Appraisal No. 364 [2015]

NZ Brick Distributors Canterbury Clay Bricks Clay Bricks Ltd Brick and Stone Imports T/A Midland Brick NZ Full contact details are given on page 9.

Bituminous Roofing Underlay & Valley Guard

Transcription:

Product 1.1 Technobond is a range of polyester fibre insulation used as thermal and acoustic insulating material in ceilings, roofs and walls of buildings. Appraisal No.69 [010] BRANZ Appraisals Technical Assessments of products for building and construction BRANZ APPRAISAL No. 69 (010) technobond polyester thermal insulation Ellis Fibre Ltd PO Box 701 Dunedin Tel: 0 476 41 Fax: 0 476 4745 Email: info@ellis-fibre.co.nz Web: www.ellis-fibre.co.nz BRANZ Limited Private Bag 50 908 Porirua City New Zealand Tel: +64 4 7 1170 Fax: +64 4 7 1171 www.branz.co.nz Scope.1 Technobond Polyester Insulation has been appraised as a thermal insulation material for ceilings, roofs and walls of buildings within the following scope: framed or part-framed domestic and commercial buildings where the insulation remains dry during its serviceable life.. Technobond must be installed in accordance with the relevant requirements of NZS 446, the manufacturers Technical Literature and this Appraisal to meet the stated thermal performance rating of the insulation. Building Regulations New Zealand Building Code (NZBC).1 In the opinion of BRANZ, Technobond Polyester Thermal Insulation if designed, used, installed and maintained in accordance with the statements and conditions of this Appraisal, will meet or contribute to meeting the following provisions of the NZBC: Clause B DURABILITY: Performance B..1(a) not less than 50 years and B..1(b) 15 years. Technobond Polyester Thermal Insulation will meet these requirements. See Paragraph 8.1. Clause E INTERNAL MOISTURE: Performance E..1. Technobond Polyester Thermal Insulation will contribute to meeting this requirement. See Paragraphs 1.1 and 1.. Clause F HAZARDOUS BUILDING MATERIALS: Performance F..1. Technobond Polyester Thermal Insulation meets this requirement and will not present a health hazard to people. Clause H1 ENERGY EFICIENCY: Performance H1..1(a) and H1..E. Technobond Polyester Thermal Insulation will contribute to meeting these requirements. See Paragraphs 1.1 to 1.8. This is an Appraisal of an Acceptable Solution in terms of New Zealand Building Code compliance. Technobond Insulation s thermal resistance (R-Value) has been determined by AS/NZS 4859.1 which is an acceptable method. Readers are advised to check the validity of this Appraisal by referring to the Valid Appraisals listing on the BRANZ website, or by contacting BRANZ.

Technical Specification 4.1 Technobond Polyester Insulation is manufactured from non-woven thermally bonded polyester fibres. The fibres are blended, carded and thermally bonded to produce blankets, which are machine slit to the required width and cut to length. The blankets are then compression packed into plastic bags. 4. Technobond Insulation is lavender in colour and is packaged in double layer clear compression tube packaging. 4. Each packet is supplied with labelling in compliance with AS/NZS 4859.1. 4.4 The product is available as set out in Table 1. Table 1: Product Range Product Type R.6 R.6 R. R. Length Width 580 870 580 870 Thickness 140 140 170 170 Blankets per pack Weight of Pack (Kg) 4. 4. 7.4 7.4 Total Area per pack (m ) 4.5 The standard 580 mm width is designed for use with framing set out at nominal 600 mm centres. The material is also supplied at a width of 870 mm for use between framing set out at nominal 900 mm centres. 4.6 Blankets can also be pre-cut to custom widths for large orders. Blanket packaging may vary with width. Blanket length remains at 9 m for all widths. 4.7 Technobond R. cannot be used within enclosed cavities less than 170 mm in depth, and R.6 cannot be used within enclosed cavities less than 140 mm in depth. 4.8 Plastic strapping and associated fixings supplied and used by the insulation installer to control the insulation material from movement that would affect the thermal or acoustic insulation performance, must meet NZBC Clause B Durability performance requirement B..1(a) 50 years for components that are enclosed and not accessible, and performance requirement B..1(b) 15 years, for components that are accessible and can be inspected and replaced. Handling and Storage 5.1 Technobond must be stored under cover and in dry conditions. Heavy objects must not be stacked on the packs. The packs must be stored in an orientation that avoids excessive compression of the product. 5. In general, insulation products are sensitive to the length of time they are stored under compression packaging. The longer they are stored, the longer it will take for them to recover to their natural loft after unpacking. 5. Although the recovery is accelerated by warmer temperatures above 5 C, Technobond may not recover its full loft, and therefore its full R-value, if it is stored for more than 6 months in its compression pack. Technical Literature 6.1 Refer to the Appraisals listing on the BRANZ website for details of the current Technical Literature for Technobond. The Technical Literature must be read in conjunction with this Appraisal. All aspects of design, use, installation and maintenance contained in the Technical Literature and within the scope of this Appraisal must be followed. Design Information General 7.1 Technobond Insulation is designed to be used as thermal insulation to meet energy efficiency and other NZBC insulation requirements, and can provide greater ratings when required by the designer, when installed in building ceilings, roofs, and walls. 7. The building envelope must be constructed to ensure the insulation remains dry during installation and throughout the life of the building. 7. To minimise the risk of moisture transfer to the insulation, roofs must be constructed to maintain a minimum airspace of 5 mm between the insulation and the roofing underlay or other roof elements, except where a solid substrate is used under the roof cladding material. (Note: some roofing may still require ventilation clearance.) 7.4 The clearances specified in the installation instructions, or specified by the manufacturer of heating appliances and recessed light fittings must be met. The use of recessed light fittings may therefore reduce the thermal performance of insulated ceilings. This factor must be taken into account in the assessment of compliance with NZBC Clause H1 Energy Efficiency. 7.5 Where the insulation material is not laid directly on a ceiling lining or over ceiling battens or joists, it must be adequately supported by galvanised wire netting or some other suitable corrosion resistant material. This applies to commercial buildings. 7.6 When the insulation is installed in a wall with a drained cavity where the stud spacings are greater than 450 mm, an intermediate means of restraining the insulation from bulging into the cavity must be installed in accordance with NZBC Acceptable Solution E/AS1 Paragraph 9.1.8.5. 7.7 Where the insulation is installed in exterior walls, the insulation material nominal thickness is to be selected to provide a snug close fit of the insulation between the building wrap and the interior wall lining. Durability Serviceable Life 8.1 Where the building is maintained so that provisions of the NZBC E and E Clauses are met, and where the insulation is not crushed or exposed to conditions that will diminish its thermal performance, (e.g. moisture), and where the material is accessible then Technobond can expect to have a serviceable life of at least 15 years. Technobond can also expect to have a serviceable life of 50 years when installed in dry, non-accessible enclosed construction cavities. Maintenance 9.1 The building must be maintained weatherproof at all times. If, during normal routine maintenance it is discovered that moisture has entered the building envelope, or that dampness has occurred because of leaking plumbing or some other source, then that source must be repaired immediately. Wet or damp insulation must be removed and then replaced with new insulation of an equivalent thermal rating. Cavities must be clean, dry and free of all contaminants and mould before fitting new insulation. NZS 446 Paragraph. gives guidance on thermal insulation maintenance due to water damage.

Outbreak of Fire 10.1 Technobond must be separated or protected from sources of heat such as chimneys, fireplaces, flues and fuel burning appliances in accordance with the requirements of NZBC Acceptable Solution C/AS1 Part 9. External Moisture 11.1 The total building envelope must comply with the requirements of NZBC E to ensure that the insulation remains dry in use. 11. The moisture content of the construction materials at the time of enclosing the insulation must meet the requirements of NZBC Acceptable Solution E/AS1, or lower moisture content if required by the lining manufacturer. Internal Moisture 1.1 Buildings other than communal non-residential, commercial, industrial, outbuildings or ancillary buildings, must be constructed so that all habitable spaces, bathrooms, laundries and other spaces where moisture may be generated or may accumulate, have an adequate combination of thermal resistance, ventilation, and internal space temperature control. 1. Roofs and walls of housing complying with the Schedule Method for Compliance with Clause H1..E will have adequate thermal resistance. Other buildings may require more thermal insulation to satisfy the requirements of NZBC E/AS1 than that used to satisfy the energy efficiency provisions alone. Energy Efficiency Building Thermal Envelope 1.1 NZBC Verification Method H1/VM1 can be used for housing, communal residential, communal non-residential and commercial buildings. Modelling of Housing and Smaller Buildings 1. The modelling method described in NZS 418 Section. (as modified by NZBC Verification Method H1/VM1 Paragraphs 1.1. and 1.1.) is a Verification Method for NZBC Clause H1..1(a) for the following types of buildings: a) Housing, regardless of total floor area (the method is also a means of compliance with H1..E, which applies only to housing; and, b) Small buildings other than housing having a net lettable area no greater than 00 m. Building Performance Index for Housing 1. Compliance with NZBC Clause H1..E Building Performance Index (BPI) satisfies Clause H1..1(a). Modelling of Large Buildings Other Than Housing 1.4 The modelling method described in NZS 44.1 Section 4.4 is a Verification Method for NZBC Clause H1..1(a) for buildings other than Housing having a net lettable area greater than 00 m. Determining Thermal Resistance 1.5 The thermal resistance (R-values) of building elements may be verified by using NZS 414. The BRANZ House Insulation Guide Fourth Edition provides thermal resistances of common building elements and is based on calculations from NZS 414. Building Thermal Envelope 1.6 NZBC Acceptable Solution H1/AS1 can be used for housing, communal residential, communal non-residential and commercial buildings. Housing and Small Buildings 1.7 Construction in accordance with NZS 418 Sections.1 or. (as modified by NZBC Acceptable Solution H1/AS1 Paragraphs.1. and.1.4) satisfies NZBC H1..1(a) for housing of any size and all buildings having a net lettable area no greater than 00 m. 1.8 Construction in accordance with NZS 418 Sections.1 or. (as modified by NZBC Acceptable Solution H1/ AS1 Paragraphs.1. and.1.4) satisfies NZBC H1..E for housing of any size, including the external walls of multi-unit dwellings. (Note that common walls between household units of multi-unit dwellings need not comply with NZS 418.) Installation Information Installation Skill Level Requirements 14.1 Installation of Technobond must be completed by installers with an understanding of insulation installation in accordance with the instructions given within NZS 446, the Technobond Technical Literature, installation instructions and this Appraisal. General 15.1 Installation of Technobond must be in accordance with the manufacturer s Technical Literature, installation instructions and this Appraisal. Installation must be carried out by installers with a good understanding and experience of insulation practice. NZS 446 should be used as a guide for installing insulation in residential buildings. 15. The product must be installed only when the building is enclosed and when the construction materials have achieved the required maximum moisture content or less, to ensure the insulation does not become wet. 15. After release from its packaging, and its installation, Technobond will require some time to fully re-loft. The time taken to completely re-loft will depend upon the length of time the product has been packaged and stored and the ambient temperature. 15.4 Technobond is manufactured in roll sizes designed to suit ceiling framing (See Table 1). Standard blanket widths available are 580 mm or 870 mm for use with 600 mm or 900 mm framing centres respectively. Custom roll widths can also be made to special order if required. Blanket roll length remains at 9 metres for all widths. 15.5 Other cavity sizes, for example 400 mm or 450 mm in walls, can be filled using Technobond blanket but it must be accurately cut to the width required. 15.6 Where Technobond is cut to fit wall cavities, the insulation must be friction fitted into the timber framework to completely fill the cavity. This will prevent sagging over time and thermal convection within the cavity. 15.7 The insulation can also be fitted over the top of framing members but must be butted tightly from one insulation section to the next so that the potential for gaps and convective heat loss is reduced. The material must not be folded, tucked or compressed. A close, even fit provides the most efficient thermal performance. 15.8 The insulation must be continuous across the entire roof or ceiling plane between top plates of external walls, and fitted either between or over rafters, ceiling joists or truss chords. Wherever possible the insulation should be fitted beneath wiring or plumbing.

15.9 Where recessed lights are present in insulated walls or ceilings, the thermal performance of the insulated space may be reduced, and/or the overheating risk to surrounding materials may be increased. Only a specific category of marked lights (F HAT requiring independent verification) can be covered with insulation. Others require a minimum clearance between the recessed light and insulation, as specified in NZS 446 for lamps up to and including 100 Watts, which must be maintained unless the manufacturer of the recessed light can verify a lesser clearance is appropriate. For recessed lights designed for use with lamps exceeding 100 Watts, larger clearances may be required and the manufacturer s instructions must be followed. Compensation for the loss of insulation due to clearance required around recessed lights must be made to meet the requirements of NZBC Clause H1. Inspections 16.1 The Technical Literature must be referred to during the inspection of Technobond installations. Sources of Information AS/NZS 4859.1: 00 including Amendment 1: 006 Materials for the thermal insulation of buildings. BRANZ House Insulation Guide, Fourth Edition 010. NZS 418: 004 Energy efficiency housing and small building envelope. NZS 44: 1996 Energy efficiency large buildings. NZS 446: 006 Energy efficiency Installing Insulation In Residential Buildings Compliance Document for New Zealand Building Code External Moisture Clause E, Department of Building and Housing, Third Edition, July 005. Compliance Document for New Zealand Building Code Energy Efficiency Clause H1, Department of Building and Housing, Third Edition, August 007. New Zealand Building Code Handbook Department of Building and Housing, Third Edition May 007. The Building Regulations 199, up to, and including August 008 Amendment. Health and Safety 17.1 Technobond is easy to handle. However, it is recommended that a dust mask be worn when handling the product as loose fibres and dust can be disturbed. Basis of Appraisal The following is a summary of the technical investigations carried out: Tests 18.1 BRANZ has carried out thermal resistance testing of Technobond in accordance with AS/NZS 4859.1: 00 including Amendment 1: 006. Other Investigations 19.1 An assessment of the durability of Technobond has been made by BRANZ technical experts. 19. The Ellis Fibre Ltd Technical Literature and installation instructions have been reviewed by BRANZ and found to be satisfactory. Quality 0.1 The manufacture of Technobond has been examined by BRANZ, including methods adopted for quality control. Details of the manufacturing processes, production quality and composition of the raw materials used were obtained and found to be satisfactory. 0. Ellis Fibre Ltd is responsible for the quality of the product supplied. 0. Quality of installation of the product on site is the responsibility of the insulation installer. 0.4 Quality of maintenance of the building to ensure the insulation material remains dry is the responsibility of the building owner. 4

In the opinion of BRANZ, Technobond Polyester Thermal Insulation is fit for purpose and will comply with the Building Code to the extent specified in this Appraisal provided it is used, designed, installed and maintained as set out in this Appraisal. The Appraisal is issued only to Ellis Fibre Ltd, and is valid until further notice, subject to the Conditions of Appraisal. Conditions of Appraisal 1. This Appraisal: a) relates only to the product as described herein; b) must be read, considered and used in full together with the technical literature; c) does not address any Legislation, Regulations, Codes or Standards, not specifically named herein; d) is copyright of BRANZ.. Ellis Fibre Ltd: a) continues to have the product reviewed by BRANZ; b) shall notify BRANZ of any changes in product specification or quality assurance measures prior to the product being marketed; c) abides by the BRANZ Appraisals Services Terms and Conditions. d) Warrants that the product and the manufacturing process for the product are maintained at or above the standards, levels and quality assessed and found satisfactory by BRANZ pursuant to BRANZ s Appraisal of the product.. BRANZ makes no representation or warranty as to: a) the nature of individual examples of, batches of, or individual installations of the product, including methods and workmanship; b) the presence or absence of any patent or similar rights subsisting in the product or any other product; c) any guarantee or warranty offered by Ellis Fibre Ltd. 4. Any reference in this Appraisal to any other publication shall be read as a reference to the version of the publication specified in this Appraisal. 5. BRANZ provides no certification, guarantee, indemnity or warranty, to Ellis Fibre Ltd or any third party. For BRANZ P Burghout Chief Executive Date of issue: July 010