Instructions for Use Life Science Kits & Assays

Similar documents
Instructions for Use Life Science Kits & Assays

Instructions for Use Life Science Kits & Assays

Manual innuprep Plant DNA Kit - KFFLX

Instructions for Use Life Science Kits & Assays

Manual innuprep DNA Micro Kit

Life science unlimited

Manual innuprep Virus DNA Kit

Instructions for Use Life Science Kits & Assays

Manual blackprep FFPE DNA Kit

Instructions for Use Life Science Kits & Assays

Manual innuprep FFPE total RNA Kit

Manual innuspeed Tissue DNA Kit

Manual innuprep Virus DNA/RNA Kit

Manual innuprep Micro RNA Kit

Manual PME free-circulating DNA Extraction Kit

Manual innuprep Bacteria DNA Kit - IP-C96

Instructions for Use Life Science Kits & Assays

Instructions for Use Life Science Kits & Assays

Manual innuprep Virus DNA/RNA Kit - IPC96

Instructions for Use Life Science Kits & Assays

Kit for total DNA isolation from agarose gels

Instructions for Use Life Science Kits & Assays

Instructions for Use Life Science Kits & Assays

Instructions for Use (Ref /2)

Instructions for Use Life Science Kits & Assays

Instructions for Use Life Science Kits & Assays

CAT. NO. BR BR BR SIZE 8 reactions 40 reactions 80 reactions. Reagent BISULFITE 2 ml 2 2 ml 3 2 ml

Kit for total DNA purification and isolation from agarose gels

Kit for DNA purification after enzymatic reactions

Instructions for Use Life Science Kits & Assays

GeneJET Gel Extraction Kit #K0691, #K0692. }!tc!!!#!!h~ PA-K069

Kit for total DNA isolation from agarose gels

Instructions for Use Life Science Kits & Assays

SPEEDTOOLS PLASMID DNA PURIFICATION KIT

Gel Extraction Mini Spin Column Kit. UltraPrep Gel-Ex. Purification of DNA fragments and plasmids from agarose gels

Thermo Scientific GeneJET NGS Cleanup Kit

CAT. NO. BR BR BR SIZE 10 preps 50 preps 250 preps. Buffer LYSIS LC 12 ml 25 ml 120 ml. Buffer LYSIS LD 10 ml 25 ml 125 ml

PureColumn DNA Extraction Kit

Instructions for Use (Cat. No /2)

PureColumn DNA Extraction Kit

PureColumn DNA Extraction Kit

FastGene Plasmid Mini Kit For isolation of high copy and low copy plasmid DNA

Gel Extraction & PCR Purification Combo Kit (Spin-column)

User manual. Invisorb Spin DNA Extraction Kit ** Invisorb Fragment CleanUp***

Introduction. Kit components. 50 Preps GF-PC-050. Product Catalog No. 200 Preps GF-PC Preps GF-PC Preps SAMPLE

Manual innuprep Plant DNA I Kit - IPC16

foodproof Sample Preparation Kit III

User manual Invisorb Spin Plant Mini Kit

mdi Nano Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

Gel/PCR Extraction Kit

Large DNA Fragments Extraction Kit

TaKaRa MiniBEST Agarose Gel DNA Extraction Kit Ver.4.0

foodproof Magnetic Preparation Kit III

foodproof Magnetic Preparation Kit III

Instructions for Use

Bead Type (NaI) Gel Extraction Kits

mdi Micro Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

BIO BASIC. Gel Extraction Kit. 9K s (10 preps) 9K (100 preps) 9K (200 preps) For Research Use Only

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

TIANgel Mini DNA Purification Kit

RIBO-prep. nucleic acid extraction kit Instruction Manual

UPzol RNA Isolation Solution

EZ-10 SPIN COLUMN HANDBOOK

Thermo Scientific GeneJET Whole Blood RNA Purification Mini Kit #K0761

mdi Gel Extraction Kit User Guide ADVANCED MICRODEVICES PVT. LTD. Membrane Technologies 21, Industrial Area, Ambala Cantt (INDIA)

PureSpin. Gel DNA Purification Kit. Micro Columns INSTRUCTION MANUAL. KIT COMPONENTS For Research Use Only. PureSpin.

E.Z.N.A. Gel Extraction Kit

India Contact: Life Technologies (India) Pvt. Ltd.

GenUP Bisulfite Complete Kit

Plus DNA Clean/Extraction Kit

Spin Micro DNA Extraction Kit

GenUP Virus DNA/RNA Kit

foodproof Sample Preparation Kit II

Thermo Scientific GeneJET Endo-free Plasmid Maxiprep Kit

Genomic Mini AX Bacteria+ Spin Increased efficiency kit for genomic DNA purification from Gram-positive bacteria. version 1017

QuickGene SP kit DNA whole blood (SP-DB)

MD60002 MD MD62002

INDEX KIT COMPONENTS 1 STORAGE AND STABILITY 1 INTRODUCTION 1 BENEFITS

Micro-Elute DNA Clean/Extraction Kit

GenepHlow Gel Extraction Kit

Register your instrument! MagSep Blood gdna Kit. Instructions for use

DNA Visualizer Extraction Kit

Maximum Yield Mini System. Protocol Book YPD100 // YPD300. Ver

Total RNA Mini kit for total RNA isolation from various type of samples version 0517

Description...1 Components...1 Storage... 1 Technical Information...1 Protocol...2 Examples using the kit...4 Troubleshooting...

Lysis Buffer A Wash Solution A Elution Buffer B Mini Filter Spin Columns 50 Collection Tubes 50 Elution tubes (1.7 ml) 100 Product Insert 1

Urine DNA Isolation Maxi Kit (Slurry Format) Product # 50100

96-well Genomic DNA Extraction Kit. Protocol Book. (Deep Well) Ver RBP96B-2

Size-Select Kit for NGS Library Preparation Product # 53600

Thermo Scientific GeneJET Plasmid Maxiprep Kit #K0491, #K0492

Quick and easy 7 minute protocol to select for 300 bp, 200 bp, 150 bp, 100 bp, 50 bp DNA fragments or perform a double size selection

Quick and easy 7 minute protocol to select for 300 bp, 200 bp, 150 bp, 100 bp, 50 bp DNA fragments or perform a double size selection

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

Mini SAL Salivary DNA Isolation Kit (Spin Column Method)

Extended Protocol for RNA Isolation from FFPE Sample

Version No.: 2.0 ( )

PureLink Quick Gel Extraction Kit

for intact or degraded RNAs from eukaryotic or bacterial samples with selectivity for mrnas and against rrnas

Agencourt RNAdvance Blood

(Spin Column) For purification of DNA and RNA from formalin-fixed, paraffin-embedded. tissue sections. Instruction for Use. For Research Use Only

Transcription:

Instructions for Use Life Science Kits & Assays

Order No.: 845-KS-5030010 10 reactions 845-KS-5030050 50 reactions 845-KS-5030250 250 reactions Publication No.: HB_KS-5030_e_170607 This documentation describes the state at the time of publishing. It needs not necessarily agree with future versions. Subject to change! Print-out and further use permitted with indication of source. Copyright 2017, Analytik Jena AG, AJ Innuscreen GmbH Manufacturer: AJ Innuscreen GmbH Robert-Rössle-Straße 10 13125 Berlin Made in Germany! Distribution/Publisher: Analytik Jena AG Konrad-Zuse-Straße 1 07745 Jena Germany Phone +49 3641 77 9400 Fax +49 3641 77 767776 www.analytik-jena.com info@analytik-jena.com

Contents Contents 1 Introduction... 2 1.1 Intended use... 2 1.2 Notes on the use of this manual... 3 2 Safety precautions... 4 3 Storage conditions... 5 4 Functional testing and technical assistance... 6 5 Product use and warranty... 6 6 Kit components... 7 7 Product specifications... 8 8 GHS classification... 9 8.1 Hazard phrases...10 8.2 Precaution phrases...11 8.3 EU hazard statements...11 9 Recommended steps before starting... 12 10 General procedure for DNA extraction... 12 11 Standard protocol: DNA extraction from agarose gel slices (TAE or TBE agarose gels)... 13 12 "Mini Elute" protocol: DNA extraction from agarose gel slices (TAE or TBE agarose gels)... 15 13 Troubleshooting... 17 14 Related products... 18 innuprep Gel Extraction Kit Issue 06 / 2017 1

Introduction 1 Introduction 1.1 Intended use The innuprep Gel Extraction Kit has been designed for the extraction of DNA from TAE or TBE agarose gels. The kit uses an optimized chemistry resulting in a very fast and reliable purification of DNA fragments and a high rate of recovery. 2 innuprep Gel Extraction Kit Issue 06/ 2017

Introduction 1.2 Notes on the use of this manual For easy reference and orientation, the manual uses the following warning and information symbols as well as the shown methodology: Symbol Information REF Catalogue number. 15 C N 30 C Content Contains sufficient reagents for <N> tests. Storage conditions Store at room temperature or shown conditions respectively. Consult instructions for use This information must be observed to avoid improper use of the kit and the kit components. Expiry date Lot number The number of the kit charge. Manufactured by Contact information of manufacturer. For single use only Do not use components for a second time. Note / Attention Observe the notes marked in this way to ensure correct function of the device and to avoid operating errors for obtaining correct results. The following systematic approach is introduced in the manual: The chapters and figures are numbered consecutively. A cross reference is indicated with an arrow (e.g. Notes on the use of this manual p. 3). Work steps are numbered. innuprep Gel Extraction Kit Issue 06 / 2017 3

Safety precautions 2 Safety precautions Read through this chapter carefully prior to guarantee your own safety and a trouble-free operation. Follow all the safety instructions explained in the manual, as well as all messages and information, which are shown. All due care and attention should be exercised in handling the materials and reagents contained in the kit. Always wear gloves while handling these reagents and avoid any skin contact! In case of contact, flush eyes or skin with a large amount of water immediately. FOR SINGLE USE ONLY! This kit is made for single use only! ATTENTION! Don t eat or drink components of the kit! The kit shall only be handled by educated personnel in a laboratory environment! If the buffer bottles are damaged or leaking, wear gloves and protective goggles when discarding the bottles in order to avoid any injuries. This kit could be used with potential infectious samples. Therefore, all liquid waste must be considered as potentially infectious and must be handled and discarded according to local safety regulation. Please observe the federal, state and local safety and environmental regulations. Follow the usual precautions for applications using extracted nucleic acids. All materials and reagents used for DNA or RNA isolation should be free of DNases or RNases. 4 innuprep Gel Extraction Kit Issue 06/ 2017

Storage conditions ATTENTION! Do not add bleach or acidic components to the waste after sample preparation! Emergency medical information in English and German can be obtained 24 hours a day from: Poison Information Center, Freiburg / Germany Phone: +49 (0)761 19 240. For more information, please ask for the material safety data sheet (MSDS). 3 Storage conditions The innuprep Gel Extraction Kit should be stored dry, at room temperature (15 C to 30 C). When stored at room temperature, the kit is stable until the expiration date printed on the label on the kit box. If there are any precipitates within the provided solutions solve these precipitates by careful warming. Before every use make sure that all components have room temperature. For further information see chapter Kit components ( p. 7). innuprep Gel Extraction Kit Issue 06 / 2017 5

Functional testing and technical assistance 4 Functional testing and technical assistance The Analytik Jena AG guarantees the correct function of the kit for applications as described in the manual. This product has been produced and tested in an ISO 13485 certified facility. We reserve the right to change or modify our products to enhance their performance and design. If you have any questions or problems regarding any aspects of the innuprep Gel Extraction Kit or other Analytik Jena AG products, please do not hesitate to contact us. For technical support or further information in Germany please dial +49 36 41 / 77 94 00. For other countries please contact your local distributor. 5 Product use and warranty The kit is not designed for the usage of other starting materials or other amounts of starting materials than those, referred to in the manual ( Intended use p. 2) ( Product specifications p. 8). Since the performance characteristics of our kits have not been validated for any specific application. Analytik Jena AG kits may be used in clinical diagnostic laboratory systems after the laboratory has validated the complete diagnostic system as required by CLIA 88 regulations in the U.S. or equivalents in other countries. All products sold by the Analytik Jena AG are subjected to extensive quality control procedures and are warranted to perform as described when used correctly. Any problems should be reported immediately. For research use only! 6 innuprep Gel Extraction Kit Issue 06/ 2017

Kit components 6 Kit components 15 C 30 C STORAGE CONDITIONS All components are stored at room temperature. 10 50 250 845-KS-5030010 845-KS-5030050 845-KS-5030250 Gel Solubilizer 8 ml 40 ml 180 ml Binding Optimizer 1 ml 5 ml 15 ml Washing Solution 3 ml 2 x 8 ml 2 x 40 ml LS (conc.) Elution Buffer 2 ml 2 x 2 ml 15 ml Spin Filter 10 50 5 x 50 Receiver Tubes 10 50 5 x 50 Elution Tubes 10 50 5 x 50 Manual 1 1 1 Initial steps Washing Solution Washing Solution Washing Solution LS LS LS Add 12 ml of 96-99.8 % ethanol to the bottle and mix thoroughly. Keep the bottle always firmly closed! Add 32 ml of 96-99.8 % ethanol to each bottle and mix thoroughly. Keep the bottle always firmly closed! Add 160 ml of 96-99.8 % ethanol to each bottle and mix thoroughly. Keep the bottle always firmly closed! Use only absolute/pure ethanol, NO methylated or denatured alcohol! innuprep Gel Extraction Kit Issue 06 / 2017 7

Product specifications Components not included in the kit 1.5 ml or 2.0 ml reaction tubes 96 99.8 % ethanol 7 Product specifications 1. Starting material: TAE agarose gels (up to 300 mg) TBE agarose gels (up to 300 mg) 2. Time for extraction: Approximately 20 minutes 3. Fragment length: 100 bp 30 kb 4. Binding capacity: 20 µg DNA 5. Rate of recovery: 60 90 % Depending on the length of DNA amplicons 8 innuprep Gel Extraction Kit Issue 06/ 2017

GHS classification 8 GHS classification Component Hazard contents GHS Symbol Hazard phrases Precaution phrases EUH Gel Solubilizer Guanidinium thiocyanate 50 100 % Acetic acid 1 <2.5 % Danger 302+312+ 332, 314, 412 101, 102, 103, 260,303+ 361+353, 305+351+ 338, 310, 405, 501 032 Polyethylene glycol octylphenol ether 0.3 <1.0 % Binding Optimizer Acetic acid 10 <25 % Warning 315, 319 101, 102, 103, 280,305+ 351+338, 362, 302+352, 403+233, 501 CAUTION DO NOT add bleach or acidic solutions directly to the sample-preparation waste. innuprep Gel Extraction Kit Issue 06 / 2017 9

GHS classification 8.1 Hazard phrases 314 Causes severe skin burns and eye damage. 315 Causes skin irritation. 319 Causes serious eye irritation. 412 Harmful to aquatic life with long lasting effects. 302+312+ 332 Harmful if swallowed, in contact with skin if inhaled. 10 innuprep Gel Extraction Kit Issue 06/ 2017

GHS classification 8.2 Precaution phrases 101 If medical advice is needed, have product container or label at hand. 102 Keep out of reach of children. 103 Read label before use. 260 Do not breathe dust/fume/gas/mist/vapors/spray. 280 Wear protective gloves/protective clothing/ eye protection/face protection. 310 Immediately call a POISON CENTER/doctor. 362 Take off contaminated clothing. 405 Store locked up. 501 Dispose of contents/container in accordance with local/regional/national/international regulations. 302+352 IF ON SKIN: Wash with plenty of water. 403+233 Store in a well-ventilated place. Keep container tightly closed. 303+361+353 IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water/shower. 305+351+ 338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. 8.3 EU hazard statements 032 Contact with acids liberates very toxic gas innuprep Gel Extraction Kit Issue 06 / 2017 11

Recommended steps before starting 9 Recommended steps before starting Heat thermal mixer or water bath to 50 C. Ensure that the Washing Solution LS has been prepared according to the instruction ( "Kit components" p. 7). Centrifugation steps should be carried out at room temperature. Optionally: heat the needed amount of Elution Buffer to 50 C. The final elution step with heated Elution Buffer will increase the DNA yield! 10 General procedure for DNA extraction Gel solubilization Binding of DNA onto Spin Filter Washing of the bound DNA Elution of DNA 12 innuprep Gel Extraction Kit Issue 06/ 2017

Standard protocol: DNA extraction from agarose gel slices (TAE or TBE agarose gels) 11 Standard protocol: DNA extraction from agarose gel slices (TAE or TBE agarose gels) The standard protocol allows the elution of the bound DNA fragment with standard volumes of Elution Buffer (30 50 µl)! IMPORTANT! Optionally, heat the needed amount of Elution Buffer to 50 C. The final elution step with heated Elution Buffer will increase the DNA yield! 1. Excise the DNA fragment from the agarose gel with a sharp scalpel. Minimize the agarose gel slice. Check the weight. Do not use more than 300 mg gel slice for one Spin Filter! 2. Transfer the gel slice into a 1.5 ml or 2.0 ml reaction tube and add the 650 µl Gel Solubilizer. 3. Incubate for 10 minutes at 50 C until the agarose gel slice is completely dissolved. We recommend using a shaking platform (thermal mixer, water bath or another rocking platform) for a continuous shaking of the sample. Alternatively, vortex the sample 3 4 times during incubation. 4. Add 50 µl Binding Optimizer and mix the suspension by vortexing or pipetting sometimes up and down. innuprep Gel Extraction Kit Issue 06 / 2017 13

Standard protocol: DNA extraction from agarose gel slices (TAE or TBE agarose gels) 5. Apply the sample onto the Spin Filter located in a Receiver Tube. Close the cap and centrifuge at 11,000 x g ( 11,000 rpm) for 1 minute. If the solution has not completely passed through the Spin Filter, centrifuge again at higher speed or prolong the centrifugation time. Discard the filtrate and re-use the Receiver Tube. Place the Spin Filter back into the Receiver Tube. 6. Open the Spin Filter and add 700 µl Washing Solution LS, close the cap and centrifuge at 11,000 x g ( 11,000 rpm) for 1 minute. Discard the filtrate and re-use the Receiver Tube. Place the Spin Filter back into the Receiver Tube. 7. Repeat step 6 completely. 8. Centrifuge at max. speed for 2 minutes to remove all traces of ethanol. Discard the Receiver Tube. 9. Place the Spin Filter into an Elution Tube. Carefully open the cap of the Spin Filter and add 30 50 µl Elution Buffer (optionally prewarmed to 50 C). Incubate at room temperature for 1 minute. Centrifuge at 11,000 x g ( 11,000 rpm) for 1 minute. A second elution step will increase the yield of extracted DNA. The DNA can be eluted with a lower or a higher volume of Elution Buffer (depends on the expected yield of DNA). Elution with lower volumes of Elution Buffer increases the final concentration of DNA. Store the extracted DNA at 4 C to 8 C. For long time storage placing at -22 C to -18 C is recommended. 14 innuprep Gel Extraction Kit Issue 06/ 2017

"Mini Elute" protocol: DNA extraction from agarose gel slices (TAE or TBE agarose gels) 12 "Mini Elute" protocol: DNA extraction from agarose gel slices (TAE or TBE agarose gels) The "Mini Elute" protocol allows the elution of the bound DNA fragment with low volumes of Elution Buffer (10 20 µl)! IMPORTANT! Optionally, heat the needed amount of Elution Buffer to 50 C. The final elution step with heated Elution Buffer will increase the DNA yield! 1. Excise the DNA fragment from the agarose gel with a sharp scalpel. Minimize the agarose gel slice. Check the weight. Do not use more than 300 mg gel slice for one Spin Filter! 2. Transfer the gel slice into a 1.5 ml or 2.0 ml reaction tube and add the 650 µl Gel Solubilizer. 3. Incubate for 10 minutes at 50 C until the agarose gel slice is completely dissolved. We recommend using a shaking platform (thermal mixer, water bath or another rocking platform) for a continuous shaking of the sample. Alternatively, vortex the sample 3 4 times during incubation. 4. Add 50 µl Binding Optimizer and mix the suspension by vortexing or pipetting sometimes up and down. innuprep Gel Extraction Kit Issue 06 / 2017 15

"Mini Elute" protocol: DNA extraction from agarose gel slices (TAE or TBE agarose gels) 5. Apply the sample onto the Spin Filter located in a. Close the cap and centrifuge at 11,000 x g ( 11,000 rpm) for 1 minute. If the solution has not completely passed through the Spin Filter, centrifuge again at higher speed or prolong the centrifugation time. Discard the filtrate and re-use the Receiver Tube. Place the Spin Filter back into the Receiver Tube. 6. Open the Spin Filter and add 700 µl Washing Solution LS, close the cap and centrifuge at 11,000 x g ( 11,000 rpm) for 1 minute. Discard the filtrate and re-use the Receiver Tube. Place the Spin Filter back into the Receiver Tube. 7. Repeat step 6 completely. 8. Centrifuge at max. speed for 2 minutes to remove all traces of ethanol. Discard the Receiver Tube. 9. Place the Spin Filter into an Elution Tube. Carefully open the cap of the Spin Filter and add 10 20 µl Elution Buffer (optionally prewarmed to 50 C). Incubate at room temperature for 2 minutes. Centrifuge at 11,000 x g ( 11,000 rpm) for 2 minutes. A second elution step will increase the yield of extracted DNA. The recovery rate of the elution volume is approx. 9 µl in case of use of 10 µl of Elution Buffer. The DNA can be eluted with a lower or a higher volume of Elution Buffer (depends on the expected yield of DNA). Elution with lower volumes of Elution Buffer increases the final concentration of DNA. Store the extracted DNA at 4 C to 8 C. For long time storage placing at -22 C to -18 C is recommended. 16 innuprep Gel Extraction Kit Issue 06/ 2017

Troubleshooting 13 Troubleshooting Problem / probable cause Comments and suggestions Low recovery / poor quality Incorrect Washing Solution LS or no ethanol added Poor elution of DNA Ineffective solubilization of the agarose gel slice No Binding Optimizer added Poor quality of DNA Prepare the Washing Solution LS exactly as described in the manual. Store the Washing Solution LS with firmly fixed lid. Add the Elution Buffer directly onto the center of the Spin Filter (even if a small elution volume is used). The gel slice must be completely dissolved. Add the amount of Binding Optimizer to the solubilized suspension. After binding of DNA an additional washing step with 80 % ethanol is recommended. Only use pure/non denatured ethanol. Add 600 µl of 80 % ethanol to the Spin Filter and centrifuge for 1 minute at 11,000 x g. Discard the flow through. For removing the ethanol centrifuge for 2 minutes at 11,000 x g. Continue with the elution step as described. Problems with down-stream application, e.g. ligation Contaminations with salt components Contaminations with agarose traces Contamination of the final DNA with ethanol Wash the Spin Filter as described in the manual. Wash the Spin Filter once with Gel Solubilizer. Keep the given centrifugation time, extend it if necessary (test the smell). innuprep Gel Extraction Kit Issue 06 / 2017 17

Related products 14 Related products Name Amount Order No. Products for PCR & Gel Electrophoresis innuprep PCRpure Kit 10 rxn 845-KS-5010010 50 rxn 845-KS-5010050 250 rxn 845-KS-5010250 innuprep DOUBLEpure Kit 10 rxn 845-KS-5050010 50 rxn 845-KS-5050050 250 rxn 845-KS-5050250 innutaq DNA Polymerase (5 U/µl) 500 U 845-EZ-1000500 innumix PCR MasterMix 100 rxn 845-AS-1700100 200 rxn 845-AS-1700200 innumix Green PCR MasterMix 100 rxn 845-AS-1400100 200 rxn 845-AS-1400200 innustar 100 bp DNA Ladder Express 500 µl 845-ST-1010100 5x 500 µl 845-ST-1010500 innustar 1 kb DNA Ladder Express 500 µl 845-ST-1020100 5x 500 µl 845-ST-1020500 6x Loading Dye Bromophenol Blue 3x 1.0 ml 845-ST-3010003 6x 1.0 ml 845-ST-3010006 18 innuprep Gel Extraction Kit Issue 06/ 2017

Headquarters Analytik Jena AG Konrad-Zuse-Str. 1 07745 Jena Germany Phone +49 3641 77 70 Fax +49 3641 77 9279 info@analytik-jena.com www.analytik-jena.com Pictures: Analytik Jena AG Subject to changes in design and scope of delivery as well as further technical development. Analytik Jena AG