ISO INTERNATIONAL STANDARD. Petroleum products Determination of sulfur content Wavelength-dispersive X-ray fluorescence spectrometry

Similar documents
ISO INTERNATIONAL STANDARD. Petroleum products Determination of sulfur content Wavelength-dispersive X-ray fluorescence spectrometry

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Rubber compounding ingredients Process oils Determination of glass transition temperature by DSC

ISO INTERNATIONAL STANDARD. Titanium and titanium alloys Determination of iron Atomic absorption spectrometry

ISO 2137 INTERNATIONAL STANDARD. Petroleum products and lubricants Determination of cone penetration of lubricating greases and petrolatum

ISO INTERNATIONAL STANDARD. Water quality Measurement of gross alpha and gross beta activity in nonsaline water Thin source deposit method

ISO 8307 INTERNATIONAL STANDARD. Flexible cellular polymeric materials Determination of resilience by ball rebound

ISO INTERNATIONAL STANDARD. Water quality Determination of sulfates Method by continuous flow analysis (CFA)

ISO 4587 INTERNATIONAL STANDARD. Adhesives Determination of tensile lap-shear strength of rigid-to-rigid bonded assemblies

ISO INTERNATIONAL STANDARD. Wood-based panels Determination of modulus of elasticity in bending and of bending strength

ISO 8340 INTERNATIONAL STANDARD. Building construction Sealants Determination of tensile properties at maintained extension

ISO INTERNATIONAL STANDARD. Compressed air Part 1: Contaminants and purity classes. Air comprimé Partie 1: Polluants et classes de pureté

ISO INTERNATIONAL STANDARD. Welding coordination Tasks and responsibilities. Coordination en soudage Tâches et responsabilités

ISO INTERNATIONAL STANDARD. Soil quality Extraction of thallium and determination by electrothermal atomic absorption spectrometry

ISO INTERNATIONAL STANDARD. Iron ores Determination of various elements by X-ray fluorescence spectrometry Part 1: Comprehensive procedure

ISO INTERNATIONAL STANDARD. Water quality Determination of chromium(vi) Method using flow analysis (FIA and CFA) and spectrometric detection

ISO 3369 INTERNATIONAL STANDARD. Impermeable sintered metal materials and hardmetals Determination of density

ISO 638 INTERNATIONAL STANDARD. Paper, board and pulps Determination of dry matter content Oven-drying method

ISO INTERNATIONAL STANDARD. Water quality Determination of ph. Qualité de l'eau Détermination du ph. Second edition

ISO INTERNATIONAL STANDARD. Water quality Determination of chromium(vi) Photometric method for weakly contaminated water

ISO INTERNATIONAL STANDARD. Metallic materials Vickers hardness test Part 3: Calibration of reference blocks

ISO INTERNATIONAL STANDARD. Natural gas Determination of mercury Part 2: Sampling of mercury by amalgamation on gold/platinum alloy

ISO INTERNATIONAL STANDARD. Iron ores Determination of cobalt Flame atomic absorption spectrometric method

ISO INTERNATIONAL STANDARD. Water quality Detection and enumeration of Pseudomonas aeruginosa Method by membrane filtration

ISO 1409 INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Injection containers and accessories Part 6: Caps made of aluminium-plastics combinations for injection vials

ISO INTERNATIONAL STANDARD. Iron ores Determination of copper Part 2: Flame atomic absorption spectrometric method

ISO INTERNATIONAL STANDARD. Paper, board and pulps Determination of total magnesium, total calcium, total manganese, total iron and total copper

ISO INTERNATIONAL STANDARD. Soil quality Determination of mercury in aqua regia soil extracts with coldvapour. atomic fluorescence spectrometry

ISO INTERNATIONAL STANDARD. Paints and varnishes Determination of wet-scrub resistance and cleanability of coatings

ISO INTERNATIONAL STANDARD. Earth-moving machinery Anti-theft systems Classification and performance

ISO INTERNATIONAL STANDARD. Road construction and maintenance equipment Asphalt mixing plants Terminology and commercial specifications

ISO INTERNATIONAL STANDARD

ISO 6209 INTERNATIONAL STANDARD. Rubber compounding ingredients Carbon black Determination of solventextractable

This document is a preview generated by EVS

ISO INTERNATIONAL STANDARD. Road construction and maintenance equipment Asphalt mixing plants Terminology and commercial specifications

ISO INTERNATIONAL STANDARD. Self-adhesive hanging devices for infusion bottles and injection vials Requirements and test methods

ISO 4987 INTERNATIONAL STANDARD. Steel castings Liquid penetrant inspection. Pièces moulées en acier Contrôle par ressuage. Second edition

ISO INTERNATIONAL STANDARD. Copper, lead, and zinc sulfide concentrates Determination of transportable moisture limits Flow-table method

ISO 648 INTERNATIONAL STANDARD. Laboratory glassware Single-volume pipettes. Verrerie de laboratoire Pipettes à un volume. Second edition

ISO 8339 INTERNATIONAL STANDARD. Building construction Sealants Determination of tensile properties (Extension to break)

ISO INTERNATIONAL STANDARD. Road vehicles Environmental conditions and testing for electrical and electronic equipment Part 5: Chemical loads

ISO 8872 INTERNATIONAL STANDARD. Aluminium caps for transfusion, infusion and injection bottles General requirements and test methods

INTERNATIONAL STANDARD

ISO 9231 IDF 139 INTERNATIONAL STANDARD. Milk and milk products Determination of the benzoic and sorbic acid contents

ISO 835 INTERNATIONAL STANDARD. Laboratory glassware Graduated pipettes. Verrerie de laboratoire Pipettes graduées. First edition

ISO INTERNATIONAL STANDARD. Equipment for crop protection Induction hoppers Part 2: General requirements and performance limits

ISO INTERNATIONAL STANDARD. Paper and board Determination of tensile properties Part 2: Constant rate of elongation method (20 mm/min)

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Metallic powders Determination of apparent density Part 1: Funnel method

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Metallic materials Sheet and strip Determination of plastic strain ratio

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO 3779 INTERNATIONAL STANDARD. Road vehicles Vehicle identification number (VIN) Content and structure

INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Machine-tools safety Safety requirements for the design and construction of work holding chucks

ISO INTERNATIONAL STANDARD. Meat and meat products Enumeration of presumptive Pseudomonas spp.

ISO INTERNATIONAL STANDARD. Adhesives Determination of the solubility of water-soluble or alkalisoluble pressure-sensitive adhesives

ISO 9597 INTERNATIONAL STANDARD. Cement Test methods Determination of setting time and soundness

ISO 6878 INTERNATIONAL STANDARD. Water quality Determination of phosphorus Ammonium molybdate spectrometric method

ISO INTERNATIONAL STANDARD. Hardmetals Determination of sulfur and carbon contents in cobalt metal powders Infrared detection method

ISO INTERNATIONAL STANDARD. Caps made of aluminium-plastics combinations for infusion bottles and injection vials Requirements and test methods

ISO INTERNATIONAL STANDARD. Polyethylene of raised temperature resistance (PE-RT) pipes Effect of time and temperature on the expected strength

ISO INTERNATIONAL STANDARD. Quality management systems Guidelines for configuration management

ISO 4986 INTERNATIONAL STANDARD. Steel castings Magnetic particle inspection. Pièces moulées en acier Contrôle par magnétoscopie

ISO INTERNATIONAL STANDARD. Animal and vegetable fats and oils Determination of lead by direct graphite furnace atomic absorption spectroscopy

ISO INTERNATIONAL STANDARD

ISO 4986 INTERNATIONAL STANDARD. Steel castings Magnetic particle inspection. Pièces moulées en acier Contrôle par magnétoscopie

ISO 7937 INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

INTERNATIONAL STANDARD

ISO 1952 INTERNATIONAL STANDARD. Solid mineral fuels Determination of extractable metals in dilute hydrochloric acid

ISO INTERNATIONAL STANDARD. Road vehicles Cleanliness of components of fluid circuits Part 10: Expression of results

ISO INTERNATIONAL STANDARD. Industrial fans Tolerances, methods of conversion and technical data presentation

ISO INTERNATIONAL STANDARD. Paper and board Testing of cores Part 9: Determination of flat crush resistance

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Quality requirements for fusion welding of metallic materials Part 2: Comprehensive quality requirements

ISO 3093 INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

ISO 2177 INTERNATIONAL STANDARD. Metallic coatings Measurement of coating thickness Coulometric method by anodic dissolution

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Rubber compounding ingredients Silica, precipitated, hydrated Part 1: Non-rubber tests

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Fibre-reinforced plastics Determination of fatigue properties under cyclic loading conditions

ISO INTERNATIONAL STANDARD. Hot-rolled stainless steel plates Tolerances on dimensions and shape

Sýnishorn ISO 9004 INTERNATIONAL STANDARD. Managing for the sustained success of an organization A quality management approach

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD. Plain bearings Quality control techniques and inspection of geometrical and material quality characteristics

INTERNATIONAL STANDARD

ISO 307 INTERNATIONAL STANDARD. Plastics Polyamides Determination of viscosity number. Plastiques Polyamides Détermination de l'indice de viscosité

ISO 3892 INTERNATIONAL STANDARD. Conversion coatings on metallic materials Determination of coating mass per unit area Gravimetric methods

ISO 3656 INTERNATIONAL STANDARD. Animal and vegetable fats and oils Determination of ultraviolet absorbance expressed as specific UV extinction

ISO INTERNATIONAL STANDARD. Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs

This document is a preview generated by EVS

INTERNATIONAL STANDARD

ISO 62 INTERNATIONAL STANDARD. Plastics Determination of water absorption. Plastiques Détermination de l'absorption d'eau. Third edition

ISO 2314 INTERNATIONAL STANDARD. Gas turbines Acceptance tests. Turbines à gaz Essais de réception. Third edition

ISO INTERNATIONAL STANDARD. Space systems Programme management Non-conformance control system

Transcription:

INTERNATIONAL STANDARD ISO 14596 Second edition 2007-09-15 Petroleum products Determination of sulfur content Wavelength-dispersive X-ray fluorescence spectrometry Produits pétroliers Détermination de la teneur en soufre Spectrométrie de fluorescence X dispersive en longueur d'onde Reference number ISO 14596:2007(E) ISO 2007

PDF disclaimer This PDF file may contain embedded typefaces. In accordance with Adobe's licensing policy, this file may be printed or viewed but shall not be edited unless the typefaces which are embedded are licensed to and installed on the computer performing the editing. In downloading this file, parties accept therein the responsibility of not infringing Adobe's licensing policy. The ISO Central Secretariat accepts no liability in this area. Adobe is a trademark of Adobe Systems Incorporated. Details of the software products used to create this PDF file can be found in the General Info relative to the file; the PDF-creation parameters were optimized for printing. Every care has been taken to ensure that the file is suitable for use by ISO member bodies. In the unlikely event that a problem relating to it is found, please inform the Central Secretariat at the address given below. COPYRIGHT PROTECTED DOCUMENT ISO 2007 All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISO's member body in the country of the requester. ISO copyright office Case postale 56 CH-1211 Geneva 20 Tel. + 41 22 749 01 11 Fax + 41 22 749 09 47 E-mail copyright@iso.org Web www.iso.org Published in Switzerland ii ISO 2007 All rights reserved

Contents Page Foreword... iv 1 Scope...1 2 Normative references...1 3 Principle...2 4 Reagents and materials...2 5 Apparatus...2 6 Samples and sampling...3 7 Calibration solutions...3 8 Calibration...5 9 Procedure...7 10 Calculation...7 11 Expression of results...7 12 Precision...7 13 Test report...8 ISO 2007 All rights reserved iii

Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization. International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2. The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent rights. ISO 14596 was prepared by Technical Committee ISO/TC 28, Petroleum products and lubricants. This second edition cancels and replaces the first edition (ISO 14596:1998), which has been technically revised. It also incorporates the Technical Corrigendum ISO 14596:1998/Cor. 1:1999. iv ISO 2007 All rights reserved

INTERNATIONAL STANDARD ISO 14596:2007(E) Petroleum products Determination of sulfur content Wavelength-dispersive X-ray fluorescence spectrometry WARNING The use of this International Standard may involve hazardous materials, operations and equipment. This International Standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this International Standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. 1 Scope This International Standard specifies a method for the determination of the sulfur content of liquid petroleum products, additives for petroleum products, and semi-solid and solid petroleum products that are either liquefied by moderate heating or soluble in organic solvents (see 4.1) of negligible or accurately known sulfur content. The method is applicable to products or additives having sulfur contents in the range 0,001 % (m/m) to 2,50 % (m/m); higher contents can be determined by appropriate dilution. Other elements do not interfere at concentrations anticipated in the materials subject to this analysis. NOTE material. For the purposes of this International Standard, the term % (m/m) is used to represent the mass fraction of a High concentrations of phosphorus or chlorine [typically above 3 % (m/m)] can cause bias in the sulfur result by absorbing Zr-Lα and S-Kα to different extents. It is necessary in these cases to carry out studies to determine whether this potential interference is significant. When larger amounts of molybdenum are present (typically above 50 mg/kg to 100 mg/kg), increased background radiation and spectral overlap with the sulfur signal can occur. It is necessary in these cases to inspect the relevant spectral regions, for example, to investigate the significance of this potential source of bias. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. ISO 3170:2004, Petroleum liquids Manual sampling ISO 3171:1988, Petroleum liquids Automatic pipeline sampling ISO 2007 All rights reserved 1

3 Principle The test portion and a zirconium solution as internal standard are mixed in a given mass ratio and exposed, in a sample cell, to the primary radiation of an X-ray tube. The count rates of the S-Kα at 0,537 3 nm and Zr-Lα1 at 0,607 0 nm fluorescence thus excited and the count rate of the background radiation at 0,545 nm are measured and the ratio of these net count rates calculated. The sulfur content of the sample is determined from a calibration curve prepared on the basis of sulfur calibration standards. NOTE The Siegbahn X-ray line notation (S-Kα) is used in this International Standard; the corresponding IUPAC X-ray line notation is S K-L 2,3. 4 Reagents and materials 4.1 White oil (light paraffin oil, paraffinum perliquidum), high-purity grade, sulfur content 1 mg/kg maximum. 4.2 Sulfur compounds, of sulfur content accurately known to the nearest 0,01 % (m/m), used for the preparation of the primary standards. The compounds given in 4.2.1 to 4.2.3 are suitable, and their nominal sulfur contents are given. Where the purity of these compounds is less than 99 %, certified materials are required, or the nature of all impurities and their contents should be accurately known to the nearest 0,01 % (m/m). 4.2.1 Dibenzothiophene (DBT), with a nominal sulfur content of 17,399 % (m/m). 4.2.2 Dibutyl sulfide (DBS), with a nominal sulfur content of 21,915 % (m/m). 4.2.3 Thionaphthene (benzothiophene) (TNA), with a nominal sulfur content of 23,890 % (m/m). 4.3 Certified sulfur reference materials. Use materials from a national standards body or accredited suppliers, if available. 4.4 Zirconium solution A. Zirconium octoate solution with a zirconium content in the range of 12 % (m/m) to 18 % (m/m) or another oilsoluble, sulfur-free zirconium compound dissolved in white oil (4.1) to provide a zirconium mass fraction in the range of 12 % (m/m) to 18 % (m/m). 4.5 Zirconium solution B. Dissolve the zirconium solution A (4.4) with white oil (4.1) to provide a zirconium mass fraction of approximately 1 % (m/m). 5 Apparatus 5.1 Wavelength-dispersive X-ray fluorescence (WDXRF) spectrometer, consisting of any suitable spectrometer that incorporates the design features listed in Table 1. It shall be set up according to the manufacturer's instructions. 2 ISO 2007 All rights reserved

Table 1 General requirements of spectrometer Component Requirement Anode Rhodium, scandium or chromium target Voltage a 30 kv to 50 kv Current a 30 ma to 70 ma Collimator Coarse Analysing crystal Germanium, pentaerythritol, or graphite Optical path Helium Cell window Polyester or polypropylene film, sulfur-free, thickness 2 µm to 6 µm Detector Gas-flow proportional counter with a pulse-height analyser a A lower-power system may be used, provided that it has been validated to meet the requirements specified in 8.3 and Clause 12. 5.2 Analytical balance, capable of weighing to the nearest 0,1 mg. 5.3 Homogenizer, non-aerating, high-speed shear type, or heatable magnetic stirrer or, for example, an ultrasonic stirrer. 5.4 Flasks, 50 ml capacity, narrow-necked, conical, made of borosilicate glass and fitted with a groundglass stopper. Use flasks of higher capacity for stock solutions (7.2). 6 Samples and sampling 6.1 Unless otherwise specified, samples shall be taken in accordance with the procedure described in ISO 3170 or ISO 3171. 6.2 Test portions from the samples shall be drawn after thorough mixing and subdivision. Heat viscous samples to a temperature that renders the sample liquid and homogenize, using the homogenizer (5.3) as necessary. NOTE For the purpose of this procedure, the term sample also includes solutions prepared from additives, semisolid or solid petroleum products that have been appropriately pre-treated and/or diluted. 7 Calibration solutions 7.1 General Use either certified reference materials (4.3) or primary standards prepared from sulfur compounds (4.2) dissolved in white oil (4.1) as a basis for the preparation of the appropriate range of sulfur stock solutions. 7.2 Preparation of stock solutions Weigh, to the nearest 0,1 mg, a quantity of sulfur compound (4.2) or certified reference material (4.3) to prepare stock solutions of approximately 2,50 % (m/m) and 0,10 % (m/m) sulfur content, calculated to the nearest 0,001 % (m/m), and dissolve in white oil (4.1) at room temperature. Mix the contents thoroughly using a homogenizer (5.3). ISO 2007 All rights reserved 3

The approximate quantities of sulfur compounds (4.2) for addition to 100 g of white oil (4.1) to prepare the stock solutions are as follows: DBT (4.2.1): 16,75 g [2,5 % (m/m)] and 0,5 g [0,1 % (m/m)] DBS (4.2.2): 12,85 g [2,5 % (m/m)] and 0,45 g [0,1 % (m/m)] TNA (4.2.3): 11,65 g [2,5 % (m/m)] and 0,40 g [0,1 % (m/m)] It is recommended that a polytetrafluoroethylene or glass-coated magnetic stirrer and stirring device be used to mix the contents of the flask. Calculate the exact sulfur content, w S,2, as a percentage by mass, to three decimal places, in each case from the amounts of white oil and sulfur compound used as given in Equation (1): mc ws,1 ws,2 = mc + mo (1) where m C w S,1 m O is the mass of the sulfur compound, expressed in grams; is the sulfur content of the sulfur compound, expressed as a percentage by mass; is the mass of white oil, expressed in grams. 7.3 Preparation of standard solutions 7.3.1 High range [0,1 % (m/m) to 2,5 % (m/m)] Into 50 ml flasks (5.4), weigh to the nearest 0,1 mg, the appropriate quantity of the 2,5 % (m/m) stock solution (7.2) to produce approximately 25 g of each standard solution of sulfur contents approximately 2,0 % (m/m), 1,5 % (m/m), 1,0 % (m/m), 0,7 % (m/m), and 0,4 % (m/m). Add white oil (4.1) to make up to approximately 25 g and re-weigh to the nearest 0,1 mg. Calculate the sulfur content, w S,3, of the standard solution to the nearest 0,001 % (m/m), using Equation (2): ( m2 m1) ws,2 ws,3 = m3 m1 (2) where m 1 m 2 m 3 w S,2 is the mass of the flask, expressed in grams; is the mass of the flask plus stock solution, expressed in grams; is the mass of the flask plus stock solution plus white oil, expressed in grams; is the sulfur content of the stock solution, expressed as a percentage by mass. 7.3.2 Low range [0,001 0 % (m/m) to 0,1 % (m/m)] Prepare standard solutions in the same manner as described in 7.3.1 using the 0,1 % (m/m) stock solution (7.2) to give standard solutions of approximately 0,075 % (m/m), 0,05 % (m/m), 0,025 % (m/m), 0,010 % (m/m), 0,005 % (m/m) and 0,001 % (m/m). Calculate the sulfur content to the nearest 0,000 1 % (m/m) using the Equation (2). 4 ISO 2007 All rights reserved

7.4 Preparation of calibration solutions 7.4.1 High range [0,1 % (m/m) to 2,5 % (m/m)] Weigh 20,00 g ± 0,01 g of each of the standard solutions (7.3.1) and the two stock solutions (7.2) into separate flasks (5.4), and add 5,00 g ± 0,01 g of the zirconium solution A (4.4). Mix thoroughly at room temperature (18 C to 28 C) using a homogenizer (5.3). 7.4.2 Low range [0,001 0 % (m/m) to 0,1 % (m/m)] Weigh 20,00 g ± 0,01 g of the low sulfur stock solution and each of the standard solutions (7.3.2) into separate flasks (5.4) and add 2,00 g ± 0,01 g of the zirconium solution B (4.5). Mix thoroughly at room temperature (18 C to 28 C) using a homogenizer (5.3). 7.5 Storage of standards Store certified reference standards in accordance with the instructions of the certifying organization, and use within the timeframe specified. Store standards prepared from white oil and sulfur compounds in dark glass-stoppered bottles in a cool dark place. NOTE The stability of prepared standards, under the above storage conditions, is at least six months. 8 Calibration 8.1 General After the spectrometer has been set up and checked (5.1), purge the optical path thoroughly with helium. 8.2 High-range calibration curve [0,1 % (m/m) to 2,5 % (m/m)] Transfer each of the calibration solutions (7.4.1) to a sample cell, and in a sequence of increasing sulfur content, place them in the spectrometer for exposure to the primary radiation. Measure the count rates, I S and I Zr, of the excited S-Kα (0,537 3 nm) and Zr-Lα1 (0,607 0 nm) fluorescence radiation. Calculate the gross count ratio, R, using Equation (3). To determine the calibration curve, the relevant gross count ratio, R, is plotted against the corresponding sulfur content of the calibration solution; the calibration curve shall then be calculated and stored using the linear model according to Equation (4). The regression calculation may be carried out either separately or using the spectrometer calculator. R I S = (3) I Zr R() x = a + bx (4) where R I S I Zr x is the gross count ratio for the relevant determination; is the count rate of the S-Kα X-ray fluorescence radiation at 0,537 3 nm; is the count rate of the Zr-Lα1 X-ray fluorescence radiation at 0,607 0 nm; is the sulfur content of the relevant calibration solution, expressed as a percentage by mass; ISO 2007 All rights reserved 5

a, b are the parameters from the regression calculation; R(x) is the gross count ratio computed from the regression calculation for the content, x. 8.3 Low-range calibration curve [0,001 0 % (m/m) to 0,1 % (m/m)] Proceed as in 8.2 using the low range calibration solutions (7.4.2), and also measure the background radiation, I B, at 0,545 nm. As the fluorescence radiation is diminished by the sample cell window (see Table 1), a thin film of approximately 2 µm thickness (polyester) or approximately 4 µm thickness (polypropylene) shall be used for the calibration solutions and test portions (9.2) of low sulfur content. The setting of the spectrometer shall be such that at least 50 000 counts are counted for the Zr-Lα1 line over the total measurement period. Calculate the net count ratio, R 0, using Equation (5). To determine the calibration curve, the relevant net count ratio, R 0, is plotted against the corresponding sulfur content of the calibration solution; the calibration curve shall then be calculated and stored using the linear model according to Equation (6). The regression calculation may be carried out either separately or using the spectrometer calculator. R where 0 I = I S Zr I B I B R 0 () x = a+ bx (6) (5) R 0 I S I Zr I B x is the net count ratio for the relevant determination; is the count rate of the S-Kα X-ray fluorescence radiation at 0,537 3 nm; is the count rate of the Zr-Lα1 X-ray fluorescence radiation at 0,607 0 nm; is the count rate of the background radiation at 0,545 nm; is the sulfur content of the relevant calibration solution, expressed as a percentage by mass; a, b are the parameters from the regression calculation; R 0 (x) is the net count ratio computed from the regression calculation for the content, x. 8.4 Checking Prior to a measurement series (calibration and/or measurement), but in any case at least once daily, the manufacturer's specifications shall be used to check that the spectrometer is operating correctly, so that an optimum performance and a consistent standard of highest possible quality is ensured. NOTE 1 Many modern WDXRF systems use drift monitoring and correction to ensure that systems produce accurate data over long periods of time without the requirement to recalibrate. Performance checks should be performed on a regular basis, since such checks give valuable information about the status and stability of the spectrometer. Check the calibration curves regularly. In regular use, check at least two points on each calibration curve by using quality control samples with known sulfur contents not less frequently than every three months. Check immediately when using a new batch of films. If the check result differs by more than 0,71 of the reproducibility given in this International Standard (see 12.2), execute a recalibration. It is recommended that a control chart analysis be carried out. 6 ISO 2007 All rights reserved

9 Procedure 9.1 General For some products, e.g. residual oils, it can be necessary to deviate from the provisions given in 9.2 and 9.3, that is, to increase the maximum temperature from 100 C to 120 C in order to obtain a homogenous sample. In these cases, this deviation shall be mentioned in the test report (Clause 13, item e). 9.2 Samples with sulfur contents between 0,1 % (m/m) and 2,5 % (m/m) Weigh 20,00 g ± 0,01 g of the sample for analysis (see Note in Clause 6) into a flask (5.4) and add 5,00 g ± 0,01 g of the zirconium solution A (4.4). Homogenize thoroughly, with heating if necessary, to a maximum temperature of 80 C. After cooling to 18 C to 28 C, proceed in accordance with 8.2 and calculate the gross count ratio, R. 9.3 Samples with sulfur contents between 0,001 0 % (m/m) and 0,1 % (m/m) Weigh 20,00 g ± 0,01 g of the sample to be analysed (see Note in Clause 6) into a flask (5.4) and add 2,00 g ± 0,01 g of the zirconium solution B (4.5). Homogenize thoroughly, with heating if necessary, to a maximum temperature of 80 C. After cooling to 18 C to 28 C, proceed in accordance with 8.3 and calculate the net count ratio, R 0. 10 Calculation Read the sulfur content from the calibration curves constructed in 8.2 or 8.3. If the sulfur content is above 2,5 % (m/m), dilute the sample with white oil (4.1) and repeat the procedure specified in 9.2. NOTE readout. Many modern instruments contain a microprocessor that retains the calibration curve and produces a digital 11 Expression of results Report the sulfur content, as a percentage by mass, rounded to the nearest 0,000 1 % (m/m) between 0,001 0 % (m/m) and 0,009 9 % (m/m), to the nearest 0,000 1 % (m/m) between 0,010 0 % (m/m) and 0,099 9 % (m/m), and to the nearest 0,01 % (m/m) between 0,10 % (m/m) and 2,50 % (m/m). 12 Precision 12.1 Repeatability The difference between two test results, obtained by the same operator with the same apparatus under constant operating conditions on identical test material would, in the long run, in the normal and correct operation of the test method, exceed the values given in Table 2 in only one case in twenty. 12.2 Reproducibility The difference between two single and independent test results, obtained by different operators working in different laboratories on identical test material would, in the long run, in the normal and correct operation of the test method, exceed the values given in Table 2 in only one case in twenty. ISO 2007 All rights reserved 7

Sulfur content % (m/m) Table 2 Precision data Repeatability limit Reproducibility limit 0,001 0 to 0,002 9 0,000 3 0,000 5 0,003 0 to 0,004 9 0,000 6 0,001 0 0,005 0 to 0,009 9 0,001 0 0,002 0 0,010 0 to 0,029 9 0,002 0,003 0,030 0 to 0,049 9 0,003 0,005 0,050 0 to 0,099 9 0,005 0,010 0,10 to 0,99 0,01 0,02 1,00 to 2,50 0,02 0,04 13 Test report The test report shall contain at least the following information: a) a reference to this International Standard (ISO 14596:2007); b) the type and complete identification of the product tested; c) the sampling procedure used (see Clause 6); d) the result of the test (see Clause 11); e) any deviation, by agreement or otherwise, from the procedure specified (e.g. see 9.1); f) the date of the test. 8 ISO 2007 All rights reserved

ISO 14596:2007(E) ICS 75.080 Price based on 8 pages ISO 2007 All rights reserved