ELECTRONIC BALLASTS FOR FLUORESCENTS LAMPS NBR e NBR 14418

Similar documents
COMPLEMENT. Switches for Electrical Fixed Installations for household and similar purposes

COMPLEMENT. RoHS PRODUCTS. Prepared by: Karin Medeiros Verified by: Natália Silva. Approved by: Mariano Mercado Approval Date: 15/01/2016

WIRES, CABLES AND CORDS

COMPLEMENT CIRCUIT BREAKERS. Prepared by: Laercio Lopes dos Santos Checked by: Vanessa Hernandes

COMPLEMENT SAFETY CERTIFICATION HOUSE APPLIANCES AND SIMILAR

Accreditation No: LAB 041. Electrical Measurement & Test Laboratory (EMTL), PCSIR Labs. Complex, Lahore Pakistan.

TÜV SÜD BABT Production Quality Certification Scheme

CERTIFICATE OF ACCREDITATION

COMPLEMENT LED luminaires for road and street lighting

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SWITCHES FOR DOMESTIC & SIMILAR PURPOSE ACCORDING TO IS 3854:1997

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained.

Green Product Mark Certification Scheme

Guidance on the Application. of ISO / IEC Accreditation International Association for Certifying Bodies

MATERIAL SPECIFICATION FOR HIGH PRESSURE SODIUM LUMINAIRES FOR UNDERPASS LIGHTING

PERMANENT DOCUMENT CIG 023. Factory Inspection Report

UL TEST REPORT AND PROCEDURE

TUV SUD BABT PRODUCTION QUALITY CERTIFICATION SCHEME

CO-ORDINATION OF NOTIFIED BODIES PPE Regulation 2016/425 RECOMMENDATION FOR USE

REQUIREMENTS FOR ACCREDITATION OF INSPECTION BODIES

Document 2007 Rev 0 December 2005 Page 1 of 8

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SELF BALLASTED LAMPS FOR GENERAL LIGHTING SERVICES ACCORDING TO IS 15111(Part 1 & 2):2002

LED Lighting Product Certification

IECEE OPERATIONAL DOCUMENT

IECEE OPERATIONAL DOCUMENT

UL TEST REPORT AND PROCEDURE

30-SDMS-01 SPECIFICATIONS FOR LOAD BREAK SWITCH

TABLE OF CONTENTS FOREWORD... 3 INTRODUCTION SCOPE NORMATIVE REFERENCES DEFINITIONS AND ABBREVIATIONS... 4

UL TEST REPORT AND PROCEDURE

Intertek Airport Lighting Equipment Certification Program

BABT Production Scheme 340

R205: SPECIFIC REQUIREMENTS: CALIBRATION LABORATORY ACCREDITATION PROGRAM. December 2011

Certificate of Compliance

IECEE OPERATIONAL DOCUMENT

SPECIFICATION FOR 11 & 33kV COMPOSITE INSULATORS Part 1: Pin Type

TABLE OF CONTENTS. FOREWORD... Error! Bookmark not defined. INTRODUCTION SCOPE NORMATIVE REFERENCES DRAWING...4

American Association for Laboratory Accreditation

A016 Traceability of measurement results compared to national and international measurement standards

INSTRUCTIONS FOR CERTIFICATION OF FACTORY PRODUCTION CONTROL

Conformity assessment and ISO CASCO for standards writers

CERTIFICATE OF ACCREDITATION

Brazilian System for Conformity Assessment (SBAC)

SCHEME OF TESTING AND INSPECTION FOR CERTIFICATION OF SWITCH-SOCKET-OUTLETS (NON-INTERLOCK TYPE) ACCORDING TO IS 15787:2008

THE KENYA POWER AND LIGHTING CO. LTD

ROUSH ESE INSPECTION PLAN

Vendor Qualification Survey

Title Procedure for setting up the accreditation of new conformity assessment schemes

NIT/Bid Document No.:

Standard Practices for Measurement Traceability in Forensic Toxicology

DATA SHEET. EM1000 Fine Ribbed Electrical Safety Matting, rated to IEC61111:2009 Class 0

Certificate of Acceptance

PERMANENT DOCUMENT CIG 024

MATERIAL SPECIFICATION FOR HIGH PRESSURE SODIUM LUMINAIRES FOR HIGHWAY LIGHTING

Abu Dhabi Certification Scheme for Polyethylene Plastic Pipe Systems Used for Utilities

COMPILED BY FUNCTIONAL RESP. APPROVED BY AUTHORIZED BY TABLE OF CONTENTS FOREWORD... 2 INTRODUCTION SCOPE NORMATIVE REFERENCES...

1.1 All testing apparatus shall be periodically checked and calibrated. Records of such checks/calibration shall be maintained.

LED Bulb Lamp (Type A) Version1.1. Certification Criteria

Features SCL-DPDT SCL-DPDT-C1 SCL-DPDT-V SCL-DPDT-S SCL-D-DPDT SCL-D-DPDT-C1 SCL-D-DPDT-V SCL-D-DPDT-S

SECTION 16496A MTS MANUAL TRANSFER SWITCH (MANUAL CONTROL ONLY) Note to Spec Writer: { } Denotes EATON Feature reference number

Conformity Assessment Facilitates Trades Development

SADCAS POLICY ISO/IEC 17020:2012 TRANSITION

EA Procedure and Criteria. For the Evaluation of Conformity. Assessment Schemes by EA. Accreditation Body Members

Quality system implementation from a manufacturers viewpoint

B. Verify that electrical installation may be made in complete accordance with all pertinent codes and regulations and the original design.

APLAC GUIDANCE ON REFERENCE MATERIAL USE AND PRODUCTION

CEN Keymark Scheme Rules for Thermostatic Radiator Valves. 2 nd Edition

La Société Nationale de Certification et d Homologation

MANUFACTURER'S RESPONSIBILITIES AND REQUIREMENTS FOR FACTORY TESTS

INTERNATIONAL STANDARD

Factory Inspection Report

Quality System ACCREDITATION For the Clinical Laboratories

A61-01 CALA Traceability Policy Revision 3.2 September 16, 2016

EA Procedure and Criteria for the Evaluation of Conformity Assessment Schemes by EA Accreditation Body Members

Use of Manufacturers Laboratories For Surveillance Testing

Ballast for Fluorescent Lamps

Title Requirements for the accreditation of calibration laboratories

ACCREDITATION A TOOL TO SUPPORT REGULATORS

Single Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

UL TEST REPORT AND PROCEDURE

APDRP SCHEME, WESCO. Technical Specification for 33KV Air Break Switch PART 1: SCOPE AND CONDITIONS

ACCREDITATION A TOOL TO SUPPORT REGULATORS

Specification Technical Requirements for Revenue Electricity Meters

ACCREDITATION A TOOL TO SUPPORT REGULATORS

APEC 2016 Component Level Safety Certification in Systems- IEC /UL1577. MARK CANTRELL Senior Applications Engineer

Procedure 14 Internal Audits

Policy on the Traceability of Measurement Results

CG Power Systems Ireland

UL TEST REPORT AND PROCEDURE

New ISO/IEC 17025:2017 Update Course (based on DIS Version) Dr. George Anastasopoulos Director, Conformity Assessment ISO/CASCO WG 44 Member

ILAC P10 TRACEABILITY

GST001 MV/LV TRANSFORMERS LOCAL SECTION CELG D

Inter American Accreditation Cooperation IAAC APPLICATION FOR THE ASSESSMENT AND ACCREDITATION OF PROFICIENCY TESTING PROVIDERS

SUPPLIER QUALITY SYSTEM SURVEY

ISO /TS 29001:2010 SYSTEMKARAN ADVISER & INFORMATION CENTER SYSTEM KARAN ADVISER & INFORMATION CENTER

SECTION HIGH EFFICIENCY DISTRIBUTION TRANSFORMERS

1.1 All testing apparatus shall be periodically checked and calibrated records of such checks/calibration shall be maintained.

PRESENTATION OVERVIEW

PART VI ENERGY CONSERVATION STANDARDS

PASS4TEST IT 인증시험덤프전문사이트

Metrology Systems & Services Ltd.

CERFLOR: The Brazilian Forest Certification System

Transcription:

COMPLEMENT Doc: 704-CRC-002-ILM ELECTRONIC BALLASTS FOR FLUORESCENTS LAMPS NBR 14417 e NBR 14418 Review: 05 page: 1/5 Prepared by: João Damião Checked by: Vanessa Hernandes Approved by: Arnaldo Barbulio Approval date: July/18/2017 1 PURPOSE This document presents the complementary criteria for the Product Certification Rule RC-002 certification and maintenance of the license to use of the SBAC Conformity Mark. Note: SBAC Sistema Brasileiro de Avaliação da Conformidade, on wich means Conformity Evaluation Brazilian System. 2 - APPLICATION FIELD This complement applies to the products that fit into teh scope of the below-referenced standard. 3 APPLICABLE STANDARDS, REGULATIONS AND REQUIREMENTS NBR 14417:1999 A.C. Supplied electronics ballasts for tubular fluorescent lamps. General and safety requirements. NBR 14418:1999 - A.C. Supplied electronics ballasts for tubular fluorescent lamps. Performance requirements. NBR ISO 9001:2000 Quality Management System Requirements. Inmetro Rule (Portaria) No. 27 dated February 18th, 2000, which validates the standardized supply voltages; Inmetro Rule (Portaria) nº 267 dated September 21 th, 2009m which establishes minimum requirements of safety and performance for the A.C. supplied electronic ballasts in alternated current for tubular fluorescent lamps Inmetro Rule (Portaria) No. 73 dated March 29th, 2006, which approves the Regulation for use of Inmetro s Marks, Accreditation Symbols and Conformity Identification Seals. Inmetro Rule (Portaria) No. 231 dated September 28 th, 2006, which regulates the transition of the use of the mark of conformity ot the Inmetro for the use of the stamp of identification of conformity. 4 - DEFINITIONS The definitions contained in the above-menioned standards shall apply, further to the definitions in 4.1 thru 4.3. 4.1 Primary Package Package that contains the product for purposes of market to the end consumers. 4.2 Homogeneous Series / FAMILY Group of electronic ballasts supplied by alternated current for fluorescent tubular lamps manufactured in the same plant and having the same basic project: that uses the same printed circuit board, partially or totally mounted, same type of enclousure and same supply voltage. 4.3 Manufacturer Responsible for manufacturing and approving the product. 5 CONFORMITY EVALUATION To evaluate the conformity, the provisions in RC-002 must be followed, complemented by the items below. 5.1 DOCUMENTATION REVIEW The following documents must be submitted to review:

Página: 2/5 Product complementary characteristics (CCP) table, to be provided by TÜV Rheinland do Brasil and filled out by the applicant; Printed circuit board layout (PCB); Enclosure drawing (casing); Electric diagram (schematic); List of materials (B.OM.) and respective main suppliers; Product marking, for the intended market (printers, labels, etc); Product packaging. 5.2 INITIAL FACTORY EVALUATION The control and quality requirements included on the Factory Inspection Report CIG 23 are checked in the factory evaluation, using the following content of the ISO 9001:2000 standard as reference: Records control to meet Standard item 4.2.4; Production control to meet Standard items 7.5.1 and 7.5.2; Purchased product check to meet Standard item 7.4.3; Product identification and traceability - to meet Standard item 7.5.3; Product preservation to meet Standard item 7.5.5; Monitoring and measuring devices control to meet Standard item 7.6; Complaint handling to meet Standard item 8.2.1; Product measuring and monitoring to meet Standard item 8.2.4; Non-conforming product control to meet Standard item 8.3; Corrective action to meet Standard item 8.5.2. 5.3 INITIAL TESTS The initial tests are all those specified in the product standards, to be applied on twenty (16) samples of the highest total wattage circuit (ballast + lamp) model, if bivolt (127V and 220V), or ten ( 08 ) samples of the highest total wattage circuit (ballast + lamp) model, if monovolt (127V or 220V) of every family to be certified. Tests shall be performed to check compliance with the Inmetro Rule (Portaria) 27/2000 requirements too. Note 1 - Non-dimmable ballast could not declare a luminous flow factor minor that a 90% of the reference ballast. Note 2 - Electronic ballasts to 28W lamps or higher, must accord with requirements of annex E of the NBR 14418. 5.4 TEST LABORATORY USAGE The tests must be performed at Laboratories authorized by an Accreditation Body signatory to a multilateral mutual recognition agreement such as ILAC, EA, or IAAC. Note 1 - The scope of the laboratory accreditation must include the test method applied. Note 2 - The tests reports issued by the laboratory must have a clearly and unequivocal identification of the authorized laboratory condition. 5.5 SURVEILLANCE AUDITS The surveillance audits must be performed at least every 06 months according to the description on this complement item 5.2. At each surveillance audit must be verified the carry out, by the manufacturer, the routine tests (item 5.7). 5.6 SURVEILLANCE TESTS

Página: 3/5 The surveillance tests must be performed after the grant of authorization for use of the conformity identification seal. Safety items to be tested: NBR14417 Items Test 1st 2nd 3rd 4th 7 Identification X 8.1 Connections X 8.2 Provisions for earth X 8.3 Creepage distances and clearance X X 8.4 Protection against accidental contact with live parts X 8.5 Protection against electric shock X 8.6 Insulation resistance after moisture treatment X X 8.7 Dielectric strength X 8.8 Abnormal conditions X 8.9 Screws, current-carrying parts and connections X 8.10 Heat and flame resistance X 8.11 Resistance to corrosion X Performance items to be tested: NBR14418 Items Test 1st 2nd 3rd 4th 5 Identification X 7 Starting Conditions X 8.1 Luminous flow factor X X X X 8.2 Total wattage of the circuit X 8.3 Luminous flow control (dimming) X 8.4 Lamp current X 9 Ballast factor - (power factor) X X X 10 Ratted current X 11 Max current filament X 12 Current wave form X X X X 13 Magnetic protection X 15 Transitory Overvoltage X 16 Functional tests for abnormal conditions X 17 Endurance X Test sampling: Supply Ballasts quantity voltage 1st sem 2nd sem 3rd sem 4th sem Bivolt 6 6 12 12 Monovolt 4 4 4 4

Página: 4/5 sampling for against-test and witness: Preferably in the same amounts of the tests, or to be consensus with a customer. Sample acquisition: Preferably from the market. 5.7 ROUTINE TESTS The manufacturer is responsible for conducting routine tests that must be performed on the complete product. Records on such tests must be kept for TÜV checks during surveillance audits. The routine tests in ballasts with metallic enclosure are: Dielectric strength 1500V (minimun) x100ma (maximun) x 1 to 3s, of 100% of the production Lighting-on under rated voltage and frequency, of 100% of the production; The routine tests in ballasts with plastic enclosure are: Lighting-on under rated voltage and frequency, of 100% of the production. 5.8 PERIODIC TESTS OF PRODUCT CHECKING The manufacture/applicant must carry out periodic tests, of models in production, with sampling defined by the manufacturer, from: Nominal current; Total wattage of the circuit (lamp + ballast); Ballast factor (power factor); Harmonic distortion; Crest factor. The manufacturer must keep result records for TÜV review. 6 - CERTIFICATION IDENTIFICATION The product, and the package when applicable, must receive individual seal of conformity Inmetro Rule (Portaria) nº 231/06, annex A.13, exemplified in the figures 1 or 2 below. The seal may not be used on visiting cards, and TÜV must formally approve the usage of the mark in advertising material, stationery or any other usage.

Página: 5/5 Figure 1 Figure 2 UC LOGO: to be used only for customers that still use it on their products and packages. 7 - CHANGES INTRODUCED Amendment of the code of the document Analyze general of document