TIMBER REFLECTIVE NOISE BARRIER - ACOUSTIC FENCING. Acoustic Barriers. Gramm Barrier Systems Registered in England and Wales No:

Similar documents
Sound-absorbing and sound-insulating barriers

Cl/SfB 1 (4-) RJ July Cempanel BUILDING BOARD CEMENT PARTICLE BOARD.

TRESPA WALL CLADDING SYSTEMS SYSTEM 700 ALUMINIUM SUB-FRAME SYSTEM

SOUND BARRIER WALLS. Specializing in Acoustics, Noise & Vibration Control. Phone Fax Penn Street Westfield, IN 46074

Optional & Reto-fit Extras

BUILDERS TIMBER DECKING GUIDE TO

NoiStop. Noice reducing acoustic wall. The benefits

Cl/SfB 1 (4-) 1 RJ December 2018 (2) Cempanel. Cement Particle Board - Building board for external and internal applications

PLAYGROUND FENCING AND GATES

movable walls Space Optimal Solutions

Revolutionary Spacer Support Bar and Bracket System for Built Up, Twin Skin Roofing and Cladding Applications

Contents. Timber framing to be installed in accordance with AS:1684 Metal framing to be installed in accordance with BCA Volume: 2

Effective Noise Barrier Design and Specification

August 2008: Issue 1. Non - Residential New Build Built - up Metal Walls

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal Insulated Wall Panel KS1000 RW

Tertu Crossings. Gangways and bridges made from wood or steel & wood combining simplicity and performances. Discover the range

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

ACOUSTIC BARRIERS DWX SERIES FOR DUCTWORK

Uniclass L151:P7113 EPIC A41:X724. CI/SfB (17.1) Hn6. Plastic Piling

Technical Data Greenscreen Acoustic Barrier

EDS TIMBER FENCING FOR SECONDARY SUBSTATIONS

Windposts and Parapet Posts

MAURER Single Seal. Expansion Joints

Product Data Sheet (rev c 16/7/15) Product: BENCHMARK Roofliner System

Acoustic Louvres. Product and Technical Data

TWO STOREY MASONRY VENEER DESIGN SOLUTION - FIRTH 10 SERIES HOLLOW MASONRY, MANORSTONE

Electrical Services Standard Specification Cable Tray Installation. May For ROYAL HOLLOWAY UNIVERSITY OF LONDON

KINGSPAN FRAME SYSTEMS KINGSPAN STEEL FRAMING SYSTEM

PARTITIONS & EXTERNAL WALLS 5

CHAPTER 3: Modern Methods of Construction (MMC)

Core. Thickness. Karrier Panel Thickness (mm) Weight (Kg/m²)*

ACOUSTIC FENCING PANELS SPECIALLY DESIGNED TO REDUCE NOISE GENERATED BY ROAD AND RAIL TRAFFIC. membro de:

DURABLE, STABLE AND LOW MAINTENANCE CLADDING

Internal Partitions - Timber Studs Internal Partitions - Steel Stud

A suitable safety. Parapets. Progressive solutions Strong & Aesthetically pleasing Easy to assemble and quick to install

Safety Barrier Solutions

Structures concrete. Structures concrete

MONK W20 range of mild steel windows

TEST REQUIREMENTS : RESULT : BS 6180: 1999: Barriers in and about buildings Code of practice - Communal domestic use Clauses 6.4.1

SWAGEBEA/fl BUILDINGS

5.0 Sports fences. Double wire panel systems Dulok Rebound 5.1 Dulok 5.2. Other systems Sports Rail 5.3 Ball Stop netting 5.4. Sports pitch systems

K12 Framing Board. Insulation

Internal walls. Creating perfect living spaces. Technical Advice Centre Tel:

Insulated Roof & Wall Panels. Product Data Sheet. Lo-Pitch Insulated Roof Panel KS1000 LP

Report Number BTC 16234A

Specification Product - Fibreglass acoustic panels Part code Size (tolerance ± 3mm)

DECK PERMIT APPLICATION

SPEC-DATA SHEET SPLIT FACE ARCHITECTURAL BLOCK A. PRODUCT NAME B. MANUFACTURER C. PRODUCT DESCRIPTION PERMACON GROUP INC.

Manufacturer of glass reinforced concrete products

June Non - Residential New Build Partition walls

PROMATECT -H External Wall With Mineral Wool

TEST REPORT No : DATE OF ISSUE : 3 October 2016 Page 1 of 9

TEST REPORT No : DATE OF ISSUE : 5 October 2016 Page 1 of 9

Determination of the sound reduction and sound absorption of a railroad noise barrier

April Section 3.3. Built-up Metal Walls

Lintels and Beams: Engineering Basis

Box Profiled Insulated Wall Panel KS1000 FC Data Sheet

DURApanel. Fencing was the best we have seen very nice to use, brilliant finish, the boss is pleased, we re stoked and will be always recommending it.

Trapezoidal Secret-Fix (SF) Insulated Roof Panel KS1000 DR/DRC Data Sheet

Sinusoidal Insulated Roof Panel KS1000 SRW Data Sheet

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panel KS1000 RW

Structural Steel Products UK & Ireland. Multideck Technical Handbook

TRADE-COURSE DPC AND FLASHING. Product. Scope. Building Regulations. Technical Specification. Appraisal No. 849 [2014] Appraisal No.

RH & RV CAVITY BARRIERS

EVOLUTION. Product Data Sheet. Design Wall Series

Insulated Roof & Wall Panels. Product Data Sheet. Curved Roof Insulated Panel KS1000 CR

FENCING TRADE SPECIFICATION

The acoustic durability of timber noise barriers on England s strategic road network

SECTION OVERHEAD DOORS. Summary of Structural Steelwork Drawings SECT IONAL OVERH EAD D OORS

Fall Protection Solutions

Environmental Noise Conference Requirements of Noise Barrier Standards Testing Results Health Effects

Design & Installation Guide

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

Core. Thickness. Biological

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

WALLSPAN. Insulated Panels for a Clean World

Acoustic Cradle Levelling System

Insulated Roof & Wall Panels Solutions. Product Data Sheet. Trapezoidal SF Insulated Roof Panel KS1000 RW SF

Product Data Sheet. Product: Benchmark Wall Liner System

Lo-Pitch Insulated Roof Panel KS1000 LP Data Sheet

Report of: RailBlazers Aluminum Railing System Post Attachment to Concrete British Columbia Building Code - Part 9

For more information on Armitage Venesta visit

The Edge Protection Federation Containment Systems Product Specification, Test Methods

Building Design Data

Marine & Offshore Fire Divisions

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS

BS 6180: 1999: Barriers in and about buildings Code of practice - General Contract use Clauses 6.4.1

BS 6180: 1999: Barriers in and about buildings Code of practice - Domestic Use Clause 6.4.1

PVC Decking & Balustrading

ROOF RENOVATION OVERSHEETING SYSTEM

Decks and Liners. Structural Steel Decks and Liner Trays

Temporary Noise Control Barrier... Page 2. Noise Reduction Damping Pad Page 4. Permanent Noise Control Barrier. Page 5

INNA-DOR. Stylish, contemporary and durable internal doorsets FIRE DOORS ACOUSTIC REDUCTION. Available with 60, 120 and 240 mins fire protection

Trapezoidal Insulated Roof Panel KS1000 RW Data Sheet

KS1000TS Trapezoidal EcoSafe Insulated Tile Support Roof Panel

ECOPLY BARRIER RIGID AIR BARRIER. Product. Scope. Building Regulations. Appraisal No. 827 [2014] Appraisal No. 827 (2014) Amended 21 August 2017

TCB & PWCB CAVITY BARRIERS Fire Protection for timber/steel frame & masonry cavity walls

Fire protection for timber frame & masonry cavity walls

RMF Intercell. NBS Specification 2013 K41

Metal Web Floor System

Transcription:

TIMBER REFLECTIVE NOISE BARRIER - ACOUSTIC FENCING Acoustic Barriers Gramm Barrier Systems Registered in England and Wales No: 05836133

We have put a lot of thought into our noise barrier range and have designed all our systems to be maintenance free for the full life span of the barrier. Timber Reflective Noise Barrier - Acoustic Fencing Full Design, Supply and Installation of Your Noise Barriers The key to a successful project using noise barriers, acoustic fencing, acoustic barriers or sound barriers is getting the right design in place at the very beginning. Our expert engineers will: Industry Leading Sound & Environmental Barriers Our Noise Barriers and Sound Fencing come in a full range of materials, allowing us to supply and install exactly the right product for you project. This includes reflective & absorptive sound barriers manufactured from: Timber Reflective Noise Barriers are Highways Agency approved and conform to the latest Tec Memo HA 65/94 (Part 1) and HA 66/95 (Part 2), as well as BS EN 1793 and BS EN 1794. Gramm Barriers systems have uniquely designed there Acoustic Fencing systems to offer the highest levels of sound reduction on the market! Our Timber Reflective Noise Barriers can be installed in any location with either concrete in or base plated posts. All our installers have worked with us for over 15 Years and work to the high levels quality and professionalism we demand! Tried, Tested, Trusted We have a reputation for providing the very best products and service on every project we undertake. We offer a full service, from the initial concept of any noise & environmental barrier project right through to commissioning and completion. We will advise and guide you on the right acoustic barrier product for your environment and produce designs and drawings showing how the barriers will be placed to be most effective. We will then manage every aspect of the sound barrier supply and installation, working closely with any other contractors involved in the project to ensure we meet all the agreed deadlines to have the noise barriers in place and working just the way you require. - Assess your needs to ensure we fully meet both your current and future requirements. - Recommend the correct type of reflective and absorptive noise barriers for your project. - Take into account ALL your needs. This includes not only how effectively your chosen noise barriers and acoustic fencing absorb and reflect sound, but whether they also look right for each particular location, and how easy they are to maintain. Having taken the time to make sure you have the best possible acoustic barriers for your project, we will supply and install them on time, and on budget. Timber, Acrylic, Aluminium, Plastic (acrylic, polycarbonate and recycled) and Concrete noise barrier panels. We also offer an additional product to enhance even further the noise reducing characteristics of acoustic screens. This commitment to providing only the highest levels of service means you can rely on Gramm Barriers, whatever your sound barrier & environmental barrier needs. 30 Call now to find out just how we can work with you and provide the best acoustic barrier installation service you could wish for. We have also designed our Noise Barriers to have a life span of 30 Years! Technical specification: Environmental Barrier of this specification has a density of 26.5 kg/m2 and achieves a Weighted Sound Reduction in excess of 29Db A in Laboratory tests. All timber materials sourced from a FSC, QA Sector Scheme 4a approved supplier.

Comprising Gramms galvanized steel RSJ noise barrier posts or C24 stress graded timber posts dependent on height & location designed to take wind loadings & turning moments with specially manufactured galvanised steel rail cleats fixed to the posts with stainless steel hex bolts. Foundation and post size dependent on height and location. ST5 concrete to be used for post foundations. Timber panels to be constructed on site. Panels to comprise horizontal structural rails, and 1 no. gravel board, fixed to posts with galvanised mild steel cleats and stainless steel bolts and coach screws. Barrier clad face side only with vertical main noise barrier boardw and cover boards and surmounted by once weathered capping, all securely fixed to rails and gravel board with stainless steel annular ring shank nails. Timber Species: Douglas Fir & Larch pressure treated Tanalith E preservative (Green) Ex Works. All in accordance with the Specification for Highway Works Technical Memorandum HA66/95, BS EN1793: parts 1-5 and BS EN1794: parts 1 & 2. Environmental Barrier of this specification has a density of 26.5 kg/m2 and achieves a Weighted Sound Reduction in excess of 29Db A in Laboratory tests. Note: Post lengths/sections, foundation sizes & post spacings may vary subject to final site survey, design calculations and safety barrier requirements. Gramm Timber Enviromental Reflective Barriers The above specification is the property of Gramm Barrier Systems Ltd. Please note: page 1 1 2 3 Structural calculations may be required by qualified persons, no responsibility can be accepted by using this design without professional advice. Design in accordance with specification for highway works clause 2504 treatment to sector scheme 4. Reflective sound screen fitted to timber posts (for illustration purposes only). Steel posts can be alternative. 4 5 6 7 Height of sound screen variable to suit specific locations. Post centres at 3.0M unless otherwise specified. Conforms and tested to BS EN 1794-1 and BS EN 1794-2. Complies with highways sector scheme 2C for the prefabrication of environmental barriers. Average density 26.5KG/M2 (excluding posts).

Reflective Sound screen Technical specification: Environmental Barrier of this specification has a density of 26.5 kg/m2 and achieves a Weighted Sound Reduction in excess of 29Db A in Laboratory tests. All timber materials sourced from a FSC, QA Sector Scheme 4a approved supplier. Size: 8.64m2 SOURCE ROOM RECEIVING ROOM Volume: Condition: Type: Location: 136m2 Clean Small Reverberation room Acoustic transmission suite Volume: Condition: Type: Location: 220m2 Clean Small Reverberation room Acoustic transmission suite TEMPERTURE HUMIDITY DLR 17.8 C 58.60% 30 Category: B3 FREQUENCY HZ R 60.00 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 2000 2500 3150 4000 5000 24.70 25.30 26.30 25.80 28.80 28.40 29.00 29.60 30.00 30.10 29.80 29.70 30.60 31.60 32.10 33.70 36.90 37.10 Sound Reduction Index R(dB) 40.00 30.00 20.00 10.00 Test Results for Gramm Barrier Systems Ltd. Issued by University of Salford (Acoustic Test Laboratory) UKAS accredited test laboratory No. 1262

Lateral Timber Movement Technical specification: Environmental Barrier of this specification has a density of 26.5 kg/m2 and achieves a Weighted Sound Reduction in excess of 29Db A in Laboratory tests. All timber materials sourced from a FSC, QA Sector Scheme 4a approved supplier. The design of the panels should avoid gaps occurring under operational conditions, such as shrinkage and warping. Natural timber movement is not prevented since boards are free to expand and contract naturally and therefore splitting and gaps do not occur. Special ring shank nails (in stainless steel) prevent removal of cover strips and boards by vandalism. Standard detail drawing: If timber is used for panels, the minimum design thickness should be based on the seasoned dry weight of the timber. A gravel board of durable material will be needed if the panels are made of material likely to deteriorate when in contact wit the ground. The above specification is the property of Gramm Barrier Systems Ltd.

Contact - Tel: 01323 872243 Fax: 01323 872244 National: 08442 259002 Email: info@grammbarriers.com Gramm Barrier Systems Ltd Head Office 18 Clinton Place, Seaford, East Sussex, BN25 1NP